Applicator Sizing - Flow

Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Sizing Sheet
General Parameters
Fluid Oil, Crude (Arab. Golf, Borneo) - Clean
Fluid
State Liquid
Character Clean Atmospheric Pressure 1.0133 bar_a
Abrasiveness Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Operating Conditions
minimum nominal maximum
Requested Flow 1 000 2 000 2 000 ton_metric/h
1 186.39 2 406.2 2 406.2 m3/h
Pressure 150 250 250 psi_g
Temperature 40 60 60 °C
Density 842.89 831.19 831.19 kg/m3
Viscosity 5.83144 3.22927 3.22927 cP
Vapor Pressure 0.9728 2.7375 2.7375 psi_a
Design pressure (min/max) 150 250 psi_g
Design temp. (min/max) 40 60 °C

Flowmeter : Promass X 500 Generation: 3 Device model: 1


Flow Principle Coriolis (Promass)
Meter Size DN 400 > DN 350
Operating range min. 0   ton_metric/h 0   ton_metric/h 0   ton_metric/h
Operating range max. 4 100   ton_metric/h 4 100   ton_metric/h 4 100   ton_metric/h
Material (sensor) * SS 1.4404/316L, ext. temp.
Process connection* PN 40 EN1092-1-B1 (DIN2501),
316L/1.4404 Flange
PED category ** : The Flowmeter is classified in Category
II. Devices in this category need
to be approved and tested to PED
requirements.

  Extended Order Code


Qty Item Description Extended Order Code
1 Flowmeter Promass X 500 8X5B3E-**************SAD2SA**+DCLK

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating. The fluids of the Applicator data base are classified to 67/548/EWG.

Print date: 31.05.2023 07:48 AM -1/5-


Applicator®: 11.16.06 / 26.08.30
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 1 000 2 000 2 000 ton_metric/h
Velocity 2.622 5.319 5.319 m/s
Sensor velocity 10.03 20.35 20.35 m/s
Pressure loss 5.54 19.68 19.68 psi
Measurement error Mass*** 0.1 0.1 0.1 %
Reynolds No. 148 274 535 510 535 510
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Warning(s)

Notice(s)

Message(s)

Print date: 31.05.2023 07:48 AM -2/5-


Applicator®: 11.16.06 / 26.08.30
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name Oil, Crude (Arab. Golf, Borneo) - Clean Fluid State Liquid
Chemical formula Calculation standard Supporting Points

Fluid description
Solid content 0   Vol%
Medium character Clean
Abrasiveness Not abrasive
Conductivity Not conductive
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Basic fluid parameters


Tc (Critical temperature) 374.1   °C Tm (Melting point) -17.16   °C
Pc (Critical pressure) 3 208.24   psi Tb (Boiling point) 99.84   °C
Heating value 0   kWh/Nm3
Temperature / Viscosity Temperature / Density
Temperature   Viscosity   Temperature   Density  
1    15 °C 13.7 cP 1    15 °C 858 kg/m3
2    50 °C 4.3 cP 2    50 °C 837 kg/m3
Temperature / Heat capacity  
Temperature   Thermal capacity  
1    10 °C 0 kJ/(kg*K)
2    100 °C 0 kJ/(kg*K)

Calculated results
Density nom. 831.19   kg/m3 Pressure nom. 250   psi_g
Viscosity nom. 3.22927   cP Temperature nom. 60   °C
Sound velocity nom. 1 790   m/s
Vapor pressure nom. 2.7375   psi_a
Thermal expansion coeff. Beta P 0.0007
Viscosity coefficient AL -8.08179
Viscosity coefficient BL 3 083.08
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0133   bar_a Atmospheric pressure 1.0133   bar_a

Print date: 31.05.2023 07:48 AM -3/5-


Applicator®: 11.16.06 / 26.08.30
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Chart sheet
Flowmeter: Promass X 500 Generation: 3 Device model: 1
Flow Principle Coriolis (Promass) Fluid Oil, Crude (Arab. Golf, Borneo) - Clean
Fluid
Meter Size DN 400 > DN 350 Pressure 150 / 250 / 250   psi_g
Temperature 40 / 60 / 60   °C Density 842.89 / 831.19 / 831.19   kg/m3
Viscosity 5.83144 / 3.22927 / 3.22927   cP
Operating range min. 0   ton_metric/h 0   ton_metric/h 0   ton_metric/h
Operating range max. 4 100   ton_metric/h 4 100   ton_metric/h 4 100   ton_metric/h

Chart (based on minimum process conditions)

Flow rate (ton_metric/h) Pressure loss (psi) Measurement error Mass(%)***


1 000 5.54585 0.1
1 100 6.63168 0.1
1 200 7.80992 0.1
1 300 9.08003 0.1
1 400 10.4415 0.1
1 500 11.894 0.1
1 600 13.4371 0.1
1 700 15.0704 0.1
1 800 16.7937 0.1
1 900 18.6065 0.1
2 000 20.5087 0.1

Print date: 31.05.2023 07:48 AM -4/5-


Applicator®: 11.16.06 / 26.08.30
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Chart (based on nominal and maximum process conditions)

Flow rate (ton_metric/h) Pressure loss (psi) Measurement error Mass(%)***


1 000 5.25446 0.1
1 100 6.29562 0.1
1 200 7.42715 0.1
1 300 8.64861 0.1
1 400 9.95963 0.1
1 500 11.3598 0.1
1 600 12.8489 0.1
1 700 14.4266 0.1
1 800 16.0926 0.1
1 900 17.8467 0.1
2 000 19.6887 0.1

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Print date: 31.05.2023 07:48 AM -5/5-


Applicator®: 11.16.06 / 26.08.30
 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).

You might also like