A uniform discharge from a closed circuit jaw crusher is 200 t/h. The crusher feeds a wet rod
mill such that 80% of the crusher product passes a 16 mm screen. The rod mill feeds a wet
ball mill at a feed size of 1.0 mm (1000 microns) and produces a product with 80% passing a
150 micron screen. The rod mill is in an open grinding circuit. Determine:
Data:
Laboratory Standard Bond Test:
Rod Mill: Grindability Index at 10 mesh =13.5 kWh/t
Ball Mill: Grindability index = 12.0kWh/t
Product size from the ball mill =150 microns
UNIVERSIDAD NACIONAL MAYOR DE SAN MARCOS
MAESTRIA GEOMETALURGIA
Eq. Bond
Mill Size Selection NO TOCAR
Chancado Close Only Rod Wet Rod Close
Arreglo Rod + Ball Rod + Ball Dry Ball Open 𝐹_1=1.3 𝑝𝑎𝑟𝑎 𝑚𝑜𝑙𝑖𝑒𝑛𝑑𝑎 𝑠𝑒𝑐𝑎
Molienda Wet Only Ball
Molino Rod 𝐹_2=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑖𝑛𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑒𝑛 𝑐𝑖𝑟
Circuito Open
Flujo 200 t/h
WiTEST 12.25 Kwh/st
F80 16,000 µm
P80 1,000 µm 𝐹_3=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑝𝑜𝑟 𝑑𝑖á𝑚
Rr 16.0
Fo 16,483 𝐹_3=( 〖 2.44∕𝐷) 〗 ^0.2
F1 1.00
F2 1.00
F4 1.00
F5 1.00
F7 1.00
F8 1.00
EG 3.20 Kwh/t
PM preliminar 640 kW
859 hp
JB 0.4
D 11.5 ft 3.51 m
L 16.0 ft 4.88 m
Rod charge 90.7 ton
ID 3.31 m
LR 4.72 m
F3 0.941
PM preliminar 603 kW
808 hp
JB 0.45
D 11.0 ft 3.35 m
L 16.0 ft 4.88 m
Rod charge 93.5 ton
ID 3.15 m 𝐹_4=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑐𝑜𝑟𝑟𝑒𝑐𝑐𝑖ó𝑛 𝑝𝑜𝑟 𝑠𝑜𝑏𝑟𝑒
LR 4.72 m
LR / ID 1.43
RRo 15
F6 1.00
PM final 812 hp
ν 15.9 rpm
νc 23.3 rpm
φc 0.68
dR 91 mm 0.091 m 𝐹_5=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑓𝑖𝑛𝑢𝑟𝑎
ρR 7,800 kg/m3 7.8 t/m3
ρS 3,010 kg/m3 3.01 t/m3
ϕ 0.30
U 1
MB 91 t
𝐹_6=𝑅𝑎𝑡𝑖𝑜 𝑑𝑒 𝑟𝑒𝑑𝑢𝑐𝑐𝑖ó𝑛 𝑒𝑛 𝑚𝑜𝑙𝑖𝑛𝑜
Se aplica después del cálculo pr
𝑡𝑜𝑟 𝑑𝑒 𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑝𝑜𝑟 𝑑𝑖á𝑚𝑒𝑡𝑟𝑜 𝑑𝑒 𝑚𝑜𝑙𝑖𝑛𝑜, 𝑠𝑒 𝑎𝑝𝑙𝑖𝑐𝑎 𝑑𝑒𝑠𝑝𝑢é𝑠 𝑑𝑒 𝑐𝑎𝑙𝑐𝑢𝑙𝑎𝑟 𝑒𝑙 𝑑𝑖á𝑚𝑒𝑡𝑟𝑜 𝑝𝑟𝑒𝑙𝑖𝑚𝑖𝑛𝑎𝑟.
15<𝑃<75
EF8
molienda sólo Chancado en circuito abierto 1.4
no barras Chancado en circuito cerrado 1.2
molienda con Chancado en circuito abierto 1.2
arras y molino Chancado en circuito cerrado F80 > 0.5" 1.2
Chancado en circuito cerrado F80 < 0.5" 1
ρb en t/m3
UNIVERSIDAD NACIONAL MAYOR DE SAN MARCOS
MAESTRIA GEOMETALURGIA
Eq. Bond
Mill Size Selection NO TOCAR
Chancado Close Only Rod Wet Rod Close
Arreglo Rod + Ball Rod + Ball Dry Ball Open 𝐹_1=1.3 𝑝𝑎𝑟𝑎 𝑚𝑜𝑙𝑖𝑒𝑛𝑑𝑎 𝑠𝑒𝑐𝑎
Molienda Wet Only Ball
Molino Ball 𝐹_2=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑖𝑛𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑒𝑛 𝑐𝑖𝑟𝑐
Circuito Close
Flujo 200 t/h
WiTEST 10.89 Kwh/st
F80 1,000 µm
P80 150 µm 𝐹_3=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑝𝑜𝑟 𝑑𝑖á𝑚
Rr 6.7
Fo 4,370 𝐹_3=( 〖 2.44∕𝐷) 〗 ^0.2
F1 1.00
F2 1.00
F4 1.00
F5 1.00
F7 1.00
F8 1.00
EG 6.00 Kwh/t
PM preliminar 1201 kW
1610 hp
JB 0.35
D 15.0 ft 4.57 m
L 15.0 ft 4.57 m
Ball charge 113.00 ton
Ball size 64.00 mm
ID 4.39 m
F3 0.914
LR 0.00 m
L / ID 1.04
RRo 13.2
F6 1.28
PM final 1410 kW
1891 hp
𝐹_4=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑐𝑜𝑟𝑟𝑒𝑐𝑐𝑖ó𝑛 𝑝𝑜𝑟 𝑠𝑜𝑏𝑟𝑒 𝑡𝑎
JB 0.45
D 15.0 ft 4.57 m
L 15.0 ft 4.57 m
Ball charge 144.00 ton
Ball size 64.00 mm
ID 4.39 m
LR 0.00 m
ν 14.1 rpm
νc 20.2 rpm 𝐹_5=𝐹𝑎𝑐𝑡𝑜𝑟 𝑑𝑒 𝑓𝑖𝑛𝑢𝑟𝑎
φc 0.70
K 350
dB 22 mm 0.022 m
ρR 7,800 kg/m3 7.8 t/m3
ρS 3.01 t/m3 𝐹_6=𝑅𝑎𝑡𝑖𝑜 𝑑𝑒 𝑟𝑒𝑑𝑢𝑐𝑐𝑖ó𝑛 𝑒𝑛 𝑚𝑜𝑙𝑖𝑛𝑜 𝑑
3,010 kg/m3 Se aplica después del cálculo pre
ϕ 0.30
U 1
MB 132 t
𝑡𝑜𝑟 𝑑𝑒 𝑒𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑝𝑜𝑟 𝑑𝑖á𝑚𝑒𝑡𝑟𝑜 𝑑𝑒 𝑚𝑜𝑙𝑖𝑛𝑜, 𝑠𝑒 𝑎𝑝𝑙𝑖𝑐𝑎 𝑑𝑒𝑠𝑝𝑢é𝑠 𝑑𝑒 𝑐𝑎𝑙𝑐𝑢𝑙𝑎𝑟 𝑒𝑙 𝑑𝑖á𝑚𝑒𝑡𝑟𝑜 𝑝𝑟𝑒𝑙𝑖𝑚𝑖𝑛𝑎𝑟.
15<𝑃<75
𝑑𝑒 𝑟𝑒𝑑𝑢𝑐𝑐𝑖ó𝑛 𝑒𝑛 𝑚𝑜𝑙𝑖𝑛𝑜 𝑑𝑒 𝑏𝑎𝑟𝑟𝑎𝑠 𝑜 𝑏𝑜𝑙𝑎𝑠, 𝑎𝑝𝑙𝑖𝑐𝑎 𝑠𝑖 𝑅_𝑅 𝑒𝑠𝑡á 𝑓𝑢𝑒𝑟𝑎 𝑑𝑒𝑙 𝑖𝑛𝑡𝑒𝑟𝑣𝑎𝑙𝑜.
plica después del cálculo preliminar.
EF8
molienda sólo Chancado en circuito abierto 1.4
o barras Chancado en circuito cerrado 1.2
molienda con Chancado en circuito abierto 1.2
arras y molino Chancado en circuito cerrado F80 > 0.5" 1.2
Chancado en circuito cerrado F80 < 0.5" 1
ρb en t/m3
𝑃_𝑁𝑂𝑀𝐼𝑁𝐴𝐿 ) . 100 = (√(3 )/1000. 𝑉𝑂𝑃𝐸𝑅𝐴𝐶𝐼𝑂𝑁 . 𝐼𝑂𝑃𝐸𝑅𝐴𝐶𝐼𝑂𝑁 . 𝐶𝑜𝑠 ϕ " " )/(𝐹_𝐷 " . " 𝑃
𝑂𝑁)/(𝐹_𝐷 " . " 𝑃_𝑁𝑂𝑀𝐼𝑁𝐴𝐿 ) = (𝐹_𝐷 " . " 𝑃_𝑁𝑂𝑀𝐼𝑁𝐴𝐿 − √(3 )/1000. 𝑉𝑂𝑃𝐸𝑅𝐴𝐶𝐼𝑂𝑁 . 𝐼𝑂
Los motores síncronos son llamados así, porque la velocidad
del rotor y la velocidad del campo magnético del estátor son
iguales. Los motores síncronos se usan en máquinas grandes Para molinos de bolas se recomienda que la conexión del
que tienen una carga variable y necesitan una velocidad motor al molino debe ser embrague de aire o acoplamiento
constante. flexible.
00. 𝑉𝑂𝑃𝐸𝑅𝐴𝐶𝐼𝑂𝑁 . 𝐼𝑂𝑃𝐸𝑅𝐴𝐶𝐼𝑂𝑁 . 𝐶𝑜𝑠 ϕ " " )/(𝐹_𝐷 " . " 𝑃_𝑁𝑂𝑀𝐼𝑁𝐴𝐿 )