You are on page 1of 1

UNIT TEST NUMBER: 430039-0 TEST DATE & TIME: 07/22/2022 05:07:17

ORDER NUMBER: M8603270-1 REG. MODEL # : MANUAL VR


WINDING SPEC: H-SG430039 REG. SERIAL # : NA

REGULATOR
UNIT INFO

TEST SPEC: - REG. FIRMWARE VERSION: -

INFO
TEST SPEC REV: - REG. SETUP: 480
VOLTAGE CONNECTION: 480 REGULATOR PT'S USED -
MODEL NUMBER: 433RDL5055 REG. SENSING V. MONITOR PT 0.0000
SERIAL NUMBER: 6007416 COMPANION SERIAL NUMBER: -
ROTOR CURE DATE: 7/2/2022 LINE LOADER DATE: 7/7/2022

BUILD & TEST INFO


ROTOR BUILDER CLOCK #: 9235 LINE LOADER CLOCK #: 7153
ROTOR INFO

MAIN ROTOR BAL. EXC - IN OZ. 0.0992 BUILD DATE: 7/18/2022


MAIN ROTOR BAL. EXC - DEG. 118 BUILDER CLOCK # : 8043
MAIN ROTOR BAL. FAN - IN OZ. 0.1183 TESTER CLOCK # : 8223
MAIN ROTOR BAL. FAN - DEG. 8 TEST STAND # : 740 Test Stand
ROTOR BALANCE DATE: 7/6/2022 SHAFT T.I.R - 2-BRG 0.001
ROTOR BALANCER CLOCK # : 9235

VOLTAGE
VOLT. ADJ. RANGE - EXCEPT DVR -

TEST
REG.
STATOR TEMP DEG. C 22.20
GEN. STATOR 1-2 0.01320 OPEN CIR. FIELD VOLT MONT. PT -
GEN. STATOR 2-3 0.01320 OPEN CIR. FIELD CURR MONT. PT -
GEN. STATOR 3-1 0.01310

SPEED
OVER-
2 MIN.

TEST
MS. RES. BALANCE % 0.7595
RPM @ RATED VOLTS 2279
RESISTANCES

GEN. ROTOR 0.2970


EXC. STATOR 21.7
EXC. ROTOR 1-2 0.02380 AIR GAP
EXC. ROTOR 2-3 0.02380 EXC. AIR GAP MINIMUM 0.02
EXC. ROTOR 3-1 0.02340
EXC. ROTOR RES. BALANCE % 1.6901 GEN. STATOR 2400
DC TO GND

PMG STATOR 1.8 GEN. ROTOR 1800


1 SEC

SPACE HEATERS PASS EXC. STATOR 1800


RTD LEADS WDG. 109 EXC. ROTOR 1800
RTF LEADS BRG. 109 PMG STATOR 1800
GEN. STATOR MEGOHMS 1000 PMG VOLTS O.C. 240
PMG
GROUND

GEN. ROTOR MEGOHMS 1000 PMG AMPS S.C. 7.95


INS. TO

EXC. STATOR MEGOHMS 1000 -


EXC. ROTOR MEGOHMS 1000 NOTE# -
PMG STATOR MEGOHMS 1000 PAINT & PACK DATE: 7/18/2022
1-2 LINE VOLTS 480.39 PAINT & PACK CLOCK #: 964
MISC.

2-3 LINE VOLTS 480.27 A ORDER (IF REQ.) DATE: 7/22/2022


OPEN CIRCUIT TESTS

3-1 LINE VOLTS 480.42 A ORDER (IF REQ.) CLOCK#: 2110


VOLTS BAL % 0.0312 FINAL AUDIT DATE: 7/22/2022
FIELD AMPS - EXC. STATOR 0.7325 FINAL AUDIT CLOCK # : 2110
UNIT RPM 1798 CART # -
PHASE SEQ. ABC @ .9 RATED VOLTS - KW 8.3
CORE
LOSS

ROTATION O.P.E. CCW @ .2 RATED VOLTS - KW 4.6


CIRCULATING CURRENT - L-AVE - CORE LOSS - KW 3.7
CIRCULATING CURRENT - T0 -
SHAFT VOLTAGE DRIVE END TO GND 0.0034
CURRENT -1 608.03
CIRCUIT TEST

CURRENT -2 609.14
SHORT

CURRENT -3 608.54
FIELD AMPS 1.3971
RPM 1797
T-O LEAD AMPS -
MAIN STATOR RESIDUAL V 1-2 56.21
RESIDUAL
VOLTAGE

MAIN STATOR RESIDUAL V 2-3 55.81


MAIN STATOR RESIDUAL V 3-1 56.45
MAX MAIN STATOR RESIDUAL- A 56.16

You might also like