You are on page 1of 1

CÁLCULO DE VASOS DE PRESSÃO

DADOS
Do 41 Do = 41 cm Ø
= = 136.67
e 0.3 e = 0.3 cm ESP. CH.
L = 300 cm COMPR.
L 300 A = 0.00065 TAB. FATOR A
= = 7.32
Do 41 B = - TAB. FATOR B
E = 2.10 x 10 6 MOD. ELAST.
2x A x E
Pa =
3 ( Do / e )

2 x 0.00065 x 2.10 x 10 6 13.6 B


Pa = Pa =
3 ( 41 / 0.3 ) Do / e

0.0013 x 2,100,000
Pa =
3 x 137

2730
Pa = = 6.659 Kgf/cm2
410

CÁLCULO ÁREA DE TROCA DE TORCADORES DE CALOR/ CONDENSADORES


DADOS
P = P x D = 3.1416 x 0.0254 D = 0.0254 m Ø INT. TUBO
L = 3m COMPR. TUBO
P = 0.079797 m P = 0.079797 m PERIMETRO Ø TUBO
At = 0.23939 m² ÁREA TUBO
At = P x L = 0.079797 x 3 Qt = 80 m QUANTIDADE TUBOS
Af = - m MOD. ELAST.
At = 0.23939 m² P = 3.1416

Af = At x Qt = 0.23939 x 80

At = 19.15119 m²