You are on page 1of 1

Explanation:

1. Transformation between absolute and relative coordinates:


outside
East North
Absolute coordinates
UTM (m) 486343.550 3501020.120
Concrete block partition (150mm thk)
Relative coordinates
Polyurethane-epoxy paint + (m) 0.000 0.000
19 Conference room
internal cement: sand Plaster

01 I/D Card room

0.125
2. Elevation measurements in meters.
FFL +853.98 (Note: Reference here should be the same as for the survey drawings)

0.125
0.125
Textile flexible pavement
3. Measurements in meters except where noted.
(carpet tiles)
FFL +853.73
4.

0.125
Mortar and sand leveling filling 70mm thk

0.125
FFL +853.48 5. The facade precast concrete panels arrangement is orientative as well as the anchorage system. The system
Ground floor slab shall be defined according to supplier and subject to approval.

0.125
Moisture barrier as per specification 6. Building perimeter sidewalk shall be adjusted according to document 4011-DRA-ABE-066-
FFL +853.23 360-0001_Urbanization drawing
FFL +853.10

References:
+852.80
TOP Walkway - 4011-SPE-ABE-050-370-0001_Buildings. Architectural
- 4011-SPE-ABE-050-370-0002_Buildings. Facilities
- 4011-SPE-ABE-050-370-0003_Buildings. HVAC system
- 4011-DRA-ABE-000-000-0006_Power block lay out
- 4011-DRA-ABE-057-370-0002_Rev06_DMS01_Security Building Basic plans drawings
- 4011-DRA-ABE-057-370-0102_Rev02_Security Building Facilities drawings
- 4011-DRA-ABE-057-370-0028_Rev05_Security Building HVAC drawings
- 4011-DRA-ABE-057-370-0029_Rev02_Security Building Fire Passive Protection drawings
- 4011-DRA-ABE-057-321-1002_Rev02_Security Building Concrete structure and foundations drawings
Steps of conference room.
- 4011-DRA-ABE-050-340-0003_Typical stairs and platforms"
Scale 1:20
- 4011-DRA-ABE-057-370-0027_Rev03_Security Building Electricity Network Lighting and sockets
- 4011-DRA-ABE-077-407-0042_Rev04_Security Building Electricity Network Single line diagram

List of abbreviations:
Geotextile fabric 200 gm/m2 Waterproof sealant:12mm
- TOC: Toc of concrete
Electrical Room 16 Servers room Outside Electrical Room Waterproof joint sealant - TOP: Top of paviment (walkway)
Insulation. Extruded polystyrene boards 100mm thk
12mm thick - FFL: Finish floor level
4mm APP Bitumen membrane fully bonded
Primer + 4mm Water Proof
membrane fully bonded Crushed sand layer of 20-30mm thk
12
Roof slope_executed with slab concrete

Various
0.012
Loose laid concrete tiles
structure_towards drainages 1% slopes
Concrete block partition (200mm thk) Concrete block partition (200mm thk)

Polyurethane-epoxy paint + Polyurethane-epoxy paint + Sealant joint detail


internal cement: sand Plaster internal cement: sand Plaster Scale 1:20.
Skirting tile (100 mm high) Dimensions in millimeters
Antistatic ceramic technical floor Antistatic ceramic technical floor
Ceramic tiles
Thecnical floor track system Thecnical floor track system
FFL +853.10 FFL +853.10 FFL +853.10

Asphalt emulsion

+852.40
Adjustable supports TOP Walkway Adjustable supports
Mortar and sand leveling
for technical floor for technical floor
filling 70mm thk
1.00

1.00
Ground floor slab Geotextile fabric 140 gm/m2
0.88

0.88
Isolation joint
Anti dust epoxy Anti dust epoxy Structural joint
Isolation joint Perimeter wall according
paint. 2 coats to foundation drawings paint. 2 coats
Perimeter wall according to Structural joint detail
foundation drawings Water proofing as per Scale 1:10
TOC+852.10 Foundation slab specification TOC+852.10
Foundation
slab

Technical floor section Technical floor with facade section 04 2019/03/07 Revision as per TRM - February 2019 IFC AGD ALNM RPR VTM
Scale 1:20 Scale 1:20
03 2018/09/28 Revision as per basic plan modification IFC AGD ALNM RPR VTM
02 2017/10/10 Revision IFC MRP DGV RPR VTM
01 2017/10/06 Revision IFC MCH/MRP DGV RPR VTM
00 2017/04/07 First Issue IFC PGL DGV RPR VTM
Rev. Edition Description: Issue Signature Signature Signature Signature
No.: Date: for: Drawn: Checked: Reviewed: Approved:
Location:

Handrail details Poliestyrene panel thk: 15 mm


Detail 1

Handrails in hot dip galvanized ASTM A36 anchorage


baseplate Galvanized Steel
carbon steel
Stangles every layers
0,23
0.03

30x40x200 mm Thk

0.03
ASTM A36 anchorage
ASTM A36 anchorage
baseplate
4

30
0,01

baseplate
0.10

0.05

Handrails in hot dip galvanized


1

40
0,0
0.03

0.10

0.08
carbon steel 0.03 0.15 0.03

0.04
200
Hot dip galvanized carbon steel 8.8 Dimensions in milimeters
threaded rod M12 with resin HIT-Y200 or ladder type
Hot dip galvanized carbon steel 8.8
similar and 150mm embedded length HD Galvanized
0.15 threaded rod M12 with resin HIT-Y200 diagonal connection
Handrails in hot dip galvanized or similar and 150mm embedded length
Hot dip galvanized carbon steel 8.8 threaded HD Galvanized
ASTM A36 anchorage baseplate
carbon steel rod M12 with resin HIT-Y200 or similar
0.05

and 150mm embedded length Handrails in hot dip galvanized


0,035

Hot dip galvanized carbon steel 8.8


threaded rod M12 with resin HIT-Y200 carbon steel Client: P. Engineer (if applicable):
0,015

0,015 Welded joint


or similar and 150mm embedded length Handrails in hot dip galvanized Stamp: Signature: P.Eng.No:
0.03

carbon steel
0.11
0.23

ASTM A36 anchorage


Welded joint EPC Contractor: EPC Subcontractor:
baseplate
0.06
0.15
0.04

0,014
0.03

Consultant:
ABENER
0.01

0,035

External Side Internal Side


ASTM A36 anchorage
ASTM A36 anchorage 0.08 0.10
0.10

0.05

baseplate
0.03

0.08 0.08 baseplate 0,015


Project: Supplier:
0.15
0.03

0.10
0.03 0.15 0.03 CONSTRUCTION OF
Murfor System
Precast galvanized steel ladder reinforcement
Waad Al-Shamal ISCCPP
Handrail Fix System (soil) Handrail Fix System (soil) Handrail Fix System (wall) Handrail Fix System (wall) Scale: Drawing No.:
General Building

Title & Subtitles:


Scale: 1/10 Scale: 1/10 Scale: 1/10 Scale: 1:10 4011-DRA-ABE-057-370-0030
Corner of facade detail with column Various Civil Works Sheets: Sheet No.:
Scale 1:15 Architecture 11 10
Size:
Security Building Int. Drawing No.
A1 Sections and details
This drawing and the design it covers are the property of Abener. They have been Project/Contract number: 4400006770
merely loaned by express agreement of the borrower, who states that it cannot be
reproduced, copied, loaned, exhibited or used under any circumstances. As an Document status: X For approval. For information.
exception, it can be used in a limited and private way, as long as Abener gives
permission to the borrower for using it through a written consent . Critical: Yes X No

You might also like