CALCULATION SHEET FOR W.F.C. & FAILURE ANALYSIS R59365-01, REV.

1 Page 1/1
29-Jan-16
For : OXY
Project : P.ON-1193 OXY
Equipment : INJECTION
Tag No. :-

PROCESS DETAILS:

Medium, mass factor (fm) : 0.9 Vapor


Flow rate at oper. Temp : 1561 kg/h
Density at oper. Temp. (pf) : 6.3 kg/m^3 248.8 m^3/h
Line size OD / WT : 273 8.18 mm
Line Velocity (V') : 1.34 m/s

TUBE DETAILS:

OD at critical section : 15.90 mm 5/8" TUBE, 0.095"W.T.


ID at critical section : 11.07 mm
Insertion Length (L) : 171.0 mm
Exposed Length (Le) : 149.0 mm
Exposed OD : 20.00 mm
Density of Material (P) : 7830 kg/m^3 [UNS S31603, SA-312 AT 38C]
Module of Elasticity (E) : 1.87E+06 kg/cm^2
Strohal Constant (S) : 0.16
Drag Coefficient (Cd) : 1.5
Allowable Stress (Se) : 116 N/mm^2
Exposed Velocity (V) : 1.42 m/s

CALCULATION:

NATURAL FREQUENCY (fn) SHED FREQUENCY (fs) DRAG FORCE ON PROBE DP BENDING MOMENT (M) BENDING STRESS (Sb)
COMMENT
(Hz) (Hz) (N/m^2) (N/mm^2) (N mm) (N/mm^2)

129 14 9.47 0.0000 2.72 0.01 HOLDER WILL NOT FAIL

Note: Conditions required are: Se > Sb ; Safety factor is n = Se/(1.5*Sb) = 8572.69 and fs / fn < 0.8 ; 0.11 < 0.80 OK!