You are on page 1of 7

KONTRAKTOR BARU CATATAN

NAMA PROJEK MUKA


UTAMA INSTLLATION OF
SURAT
PERUBAHAN IBS
SYIFA BINA SDN BHD MENAIKTARAF RUMAH KANAK-KANAK TAMAN 1
BAKTI,KEPALA BATAS,PULAU PINANG. H/SBSB/8_Rev0
DISEDIAKAN KHATIJAH/SHO
TARIKH
OLEH
13/7//2023
DISEMAK EN AHMAD TARMIZI
NAMA PENGURUS / PENGARAH PROJEK
OLEH
EN AHMAD TARMIZI / EN MOHD SUHAIMI
DILULUSKAN EN MOHD SUHAIMI
LOKASI PROSES
OLEH
PENGENALAN HAZAD ANALISIS RISIKO KAWALAN RISIKO DAN STATUS
TURUTAN KAWALAN
KERJA SEMASA KEBARANG- TAHAP
HAZAD KESAN KETERUKAN TINDAKAN STATUS PERUNDANGAN
KALIAN RISIKO
a. Temporary Struck by vehicle – - Bodily injury. -Mandatory PPE 3 3 9 - Provide proper OSHA 1994
Traffic to be worn at all traffic FMA
traffic times (safety management. (BOWEC)
boots, helmets Flagman. Clear 1986
management
and safety vest) access. Setup
establishment exclusion zone.
- Revise and to
provide safety
signage which is
translated to the
general worker’s
understanding
b. Mobilization/ i.Traffic - Bodily injury i.Implementation 2 3 6 - Revise and to OSHA 1994
Demobilizatio obstruction of traffic provide reward FMA
n/Material Handling - Material management system (BOWEC)
and Storage ii. Fall/topple of damaged 1986
machine ii. Competent
machine
iii. Lost control of operator.
machine.
iv. Poor iii. Extra care
housekeepi ng and during loading
material /unloading. Close
arrangement Supervision.

C. Machinery i.Hit/Injuries by - Bodily injury -Mandatory PPE 2 2 4 OSHA 1994


Movement moving machine to be worn at FMA
alltimes (BOWEC)
ii. Machine (safetyboots, 1986
overturn helmetsand
safety vest).
iii. Machine
collision - Appointment of
signalman.

d. Installatiom of i. Collapse of - Bodily injury - To provide 3 3 9 OSHA 1994


panel: machinery. proper access FMA
- Fatality
(BOWEC)
Lifting Operation Machinery stuck -Ensure access is 1986
- Property
into the ground damage clean

ii. Moving loads - - Road is wide


Contact with and safe
load - Serviceable
Crane with valid
iii. Mechanical CF (PMA).
failure - Collapse
of cranes boom - Lifting gears
or structure inspection and
damage of boom
color coding. No

overload. Follow
iv. Crane load chart/SWL.
overturning/
toppling.

v. Slip, trip and


fall hazard

e. Setting of panels Poor - Bodily injury - Briefing in 2 4 8 OSHA 1994


housekeepi regards this FMA
- Fatality
ng and issue during (BOWEC)
- Property 1986
material toolbox
damage
arrangement meeting.
ii. Working at
height: - Provide safety
Improper/ signage near
Unsecure the
platform & hazard area.
Edge
- Mandatory
protection
PPE
iii. Poor
to be worn at
manual
all
handling
times (safety
iv. Pinch point
boots, helmets
hazard/
and safety vest
Caught in
between-
Hand/Bodily
injury
v. Defective
Hand
tools/withou
t guarding.

iv. Poor
manual
handling
v. Pinch point
hazard/
Cau
ght in
between-
Hand/Bodily
injury
vi. Defective
Hand
tools/without
guarding -
Hand/Bodily
injury
vii. Sharp
Object/Protr
uding rebar-
Hand/Bodily
injury
viii. Falling
object – Hit
by falling
object

f. Fixing GClamp i. Failure/Inco - Minor Injury - Brief workers 2 2 4 OSHA 1994


and rrect about the FMA
installation correct (BOWEC)
Support
1986
of clamp & installation
support– method before
Dropping start of work
Panels activities.
ii. Poor
housekeepi - Provide safety
ng and signage near
material the
arrangemen hazard area.
t - Mandatory
iii. Working at PPE
height: to be worn at
Improper/U all
nsecure times (safety
platform &Edge boots, helmets
protection and safety vest)
iv. Poor
manual
handling
v. Pinch point
hazard/Cau
ght in
between-
Hand/Bodily
injury
vi. Defective
Hand
tools/withou
t guarding -
Hand/Bodily
injury
vii. Sharp
Object/Protr
uding rebar-
Hand/Bodily
injury
g. Electrical i. Electric - Major injury i. Provide 2 2 4
shock -Fire (Property adequate
Works
damaged) training.
Electrical
equipment/
wiring
to be
inspected/conn
ecte
d by electrician.
Barricade work
area. Display
signages. Work
briefing prior to
work start.
Check
all cables
before
connection.
Use of
industrial type
plugs & cable.
Standing/Const
ant
monitoring
O: To revised
that
only industrial
type plugs and
socket outlets
which are
certified by
SIRIM are
allowed on site

h. Hacking and i. Flying - Health hazard Provide safety 1 2 2


Cutting chip/particle (chemical signage near
s/Dust inhalation) the hazard area
ii. - Provide safety
Noise/Vibration signage near
the hazard are

You might also like