You are on page 1of 7

#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.

1 GENERAL REQUIREMENTS:

ASME B30.8
1.1 equipment documentation is available Sec: 8-3.1.3.1.2
(c-1)

ASME B 30.8
1.2 Previous inspection reports are checked
Sec : 8-2.1.5

GI 7.030
1.3 Daily pre-operational inspection checklists are checked (if applicable)
Para: 5.1.2

ASME B30.5
Preventive Maintenance is established and updated records are Sec:5-2.3.1
1.4
maintained ASME B 30.8
Sec :8-2.3.1

G.I. 7.025
1.5 Operator is certified (for the inspected crane type/model) and licensed
Para: 7.1

ASME B30.8
1.6 Operator manuals are available
Sec: 8-3.1.2 (e)

A sign is posted warning the operator not to rely solely on any automatic G.I. 7.030
1.7
device as a substitute for safe operating practice Para: 5.6.2

SAES-B067
1.8 Crane is painted safety yellow
Sec:4.4

SAES-B067
1.9 Crane is painted safety yellow-and-black stripes on offshore facilities
Sec:4.4

SAES-B067
1.10 Rated capacity of crane is marked (Arabic & English)
Sec:4.4

Means are provided for the operator to visually determine machine list ASME B 30.8
1.11
and machine trim. Sec : 8-1.4.4 (e)

A durable rating chart with legible letters and figures is provided and
ASME B 30.8
1.12 fixed at a location visible to the operator while seated at his control
Sec : 8-1.1.3
station

Load ratings at all operating radii and boom angles, and for all ASME B 30.8
1.13
permissible boom lengths, jib lengths, and angles are available Sec : 8-1.1.3 (a)

Recommended parts of hoist reeving, size, and type of rope for various ASME B 30.8
1.14
loads are shown either on the rating chart or in the operating manual Sec : 8-1.1.3 (c)

Essential precautionary or warning notes relative to limitations on


ASME B 30.8
1.15 equipment, operating procedures, and stability factors are provided on
Sec : 8-1.1.3 (d)
the rating chart or the operating manual

Structure integrity and capability are verified to withstand the proposed ASME B30.8
1.16
or actual duty Sec: 8-1.2.1 (a)

ASME B30.8
1.17 Protective guards are in place and Secured at areas of potential hazard
Sec :8-1.4.1 (c)

ASME B30.8
1.18 Navigational lights are provided
Sec : 8-1.4.4 (f)

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ASME B30.8
1.19 Flame arrester on fill and of gasoline tank is provided
Sec : 8-3.4.2 (a)

ASME B30.8
1.20 Fuel tank is equipped with self-closing filler cap
Sec: 8-1.4.4 (d)

Vertical clearance between crane lowest point and floor level of boat or
ASME B30.8
1.21 barge is at least 7 feet(if less than 7 feet, barracading is to be provided
Sec : 8-1.5
to protect personnel from rotating Sections)

All controls are within the reach of operator and clearly marked with ASME B30.8
1.22
functions and modes of operation Sec: 8-1.8.2

Remote control of the crane is properly working and crane stops if ASME B30.8
1.23
control signal becomes ineffective (if fitted) Sec : 8-1.8.1 (c)

ASME B30.8 Sec


1.24 Electrical motors disconnect on power failure
: 8-1.8.1 (d)

ASME B30.8 Sec


1.25 Electrical motors do not start on power return
: 8-1.8.1 (d)

Over-speeding preventing device is provided for electric motor operated ASME B30.8 Sec
1.26
cranes : 8-1.8.1 (e)

Power plant controls are provided to


• Control start, stop and lock in off position
ASME B30.8 Sec
1.27 • Control engine speed
: 8-1.8.2
• Stop diesel engines in emergency, and
• Shift selective transmissions

Controls’ forces are:


• Hand levers not greater than 35 lb (156 N) ASME B30.8
1.28
• Foot pedals not greater than 50 lb (222 N) or less than Sec : 8-1.8.3 (a)
8 lb (36 N) on foot pedals

ASME B30.8
1.29 Clutch is operating properly and within the reach of operator station
Sec : 8-1.8.4

Resistors and connectors are corrosion free, protected, ventilated and


ASME B30.8
1.30 installed to prevent the accumulation of combustible matter near hot
Sec : 8-1.8.6 (a)
parts

ASME B30.8
1.31 Resistor units are supported and do not vibrate
Sec : 8-1.8.6 (b)

ASME B30.8
1.32 Cab is provided with safety glazing glass
Sec : 8-1.10.1 (b)

Cab door swings out to open or slides rearward for sliding door type ASME B30.8
1.33
(door operation is restrained during machine operation) Sec : 8-1.10.1 (c)

ASME B30.8
1.34 Cab wipers are in good condition and operating
Sec : 8-1.10.1 (e)

A clear passageway is provided from operator's position to outside the ASME B30.8
1.35
cab Sec : 8-1.10.1 (d)

ASME B30.8
1.36 Platform to cab walkway is skid resistance
Sec : 8-1.10.2 (a)

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ASME B30.8
1.37 Handholds/steps are provided to facilitate access to the cab
Sec : 8-1.10.2 (b)

Communication method is one of the following:


• Hand signals (standard chart is posted in visible location to the
operator)
ASME B30.8
1.38 • Radio/telephone
Sec : 8-3.3.1
• Bell signal
• Special signals (to be understood and agreed upon by operator and
signalperson)

2 HOISTING COMPONENTS

Wire rope clips attached with U-bolts are having the U-bolt over the ASME B30.8
2.1
dead end of the rope and the live rope resting in the clip saddle Sec: 8-1.9.3 (b)

ASME B30.8
The rope does not have more than 6 randomly distributed broken wires
2.2 Sec : 8-2.4.3
in 1 lay or 3 in 1 strand (for running ropes)
(b-1)
ASME B30.8
The rope does not have broken outer wire at the contact point with the
2.3 Sec : 8-2.4.3
rope core (for running ropes)
(b-3)
ASME B30.8
The rope wear does not exceed 1/3 of the original diameter of outside
2.4 Sec : 8-2.4.3
individual wires
(b-4)
The rope does not have kinking, crushing, birdcaging, evidence of heat ASME B30.8
2.5 damage, ubstranding, core corrosion, main strand displacement or any Sec : 8-2.4.3
other damages (b-5&6)
ASME B30.8
2.6 The reduction does not exceed 5% Sec : 8-2.4.3
(b-7)
The ropes does not have more than two broken wires in 1 lay in ASME B30.8
2.7 sections beyond end connections or more than 1 broken wire at an end Sec : 8-2.4.3
connection (for standing ropes) (b-8)
ASME B30.8
2.8 Wire rope is not corroded Sec: 8-2.4.2
(b-2)

ASME B30.8
2.9 Rope lubrication is adequate
Sec : 8-2.4.6 (e)

ASME B30.8
2.10 Sheaves and drums are not cracked or show worn surfaces Sec : 8-2.1.3
(a-3)
ASME B30.8
2.11 Bolts and rivets around the structure are tight Sec : 8-2.1.3
(a-2)
ASME B30.8
2.12 Clutch system parts, linings, pawls and ratchet are not excessively worn Sec : 8-2.1.3
(a-5)
ASME B30.8
2.13 Brake system parts are not excessively worn Sec : 8-2.1.3
(a-5)
ASME B30.8
2.14 Rope reeving is in compliance with manufacturer's recommendations Sec : 8-2.1.2
(a-7)

Sheave sizes are not less than 15 times the nominal rope diameter for ASME B30.8
2.15
boom hoist Sec : 8-1.9.5 (a)

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
sheave sizes are not less than 18 times the nominal rope diameter for ASME B30.8
2.16
load hoist Sec : 8-1.9.5 (b)

Load block sheaves shall have pitch diameters not ASME B30.8
2.17
less than 16 times the nominal diameter of the rope used Sec : 8-1.9.5 (c)

Eye splices are in accordance with the manufacturer's ASME B30.8


2.18
recommendations and rope thimbles are used Sec : 8-1.9.3 (a)

Boom hoist drum is provided with an auxiliary a locking device


ASME B30.8
2.19 controllable from the operator’s station to hold the drum from rotating in
Sec : 8-1.6.1 (f)
the lowering direction and to hold the rated load
ASME B30.8
Boom hoist drum has at least 2 full wraps remaining on the drum when
2.20 Sec : 8-1.6.1
the boom is at lowest position
(g-1)

The load hoist mechanism is provided with a suitable clutching or power ASME B30.8
2.21
engaging device, unless directly coupled Sec : 8-1.6.2 (b)

ASME B30.8
2.22 Over hoist limit devices are operable (when provided) Sec : 8-2.2.1
(a-5)

3 BOOM COMPONENTS

ASME B30.8
All welded members and joints have no cracks, distortion, corrosion or
3.1 Sec : 8-2.1.3
other defects
(a-1)
Boom stops are provided and in good condition (one of the following;
ASME B30.8
3.2 fixed or telescopic bumper, shock absorbing bumber, hydraulic boom
Sec : 8-1.11.1 (a)
elevation cylinder, or derrick masts)

ASME B30.8
3.3 Boom angle indicator is provided and readable from operator's cab
Sec : 8-1.11.1 (C)

Boom hoist disconnect, shutoff, or hydraulic relief is provided to stop the


ASME B30.8
3.4 boom hoist automatically when the boom reaches a predetermined
Sec : 8-1.11.1 (d)
angle
ASME B30.8
3.5 Cords and lacings have no damage Sec : 8-2.1.2
(a-2)
ASME B30.8
3.6 Guy ropes are correctly tensioned Sec : 8-2.1.2
(a-9)
ASME B30.8
Derrick mast fittings and connections are in compliance with the
3.7 Sec : 8-2.1.2
manufacturer's recommendations
(a-10)
ASME B30.8
3.8 Clutch system parts, linings, pawls and ratchet are not excessively worn Sec : 8-2.1.2
(a-11)

ASME B30.8
3.9 Operational Aids are equipped and functioning
Sec: 8-1.4.3

ASME B30.8
3.10 Chain drive sprockets do not show excessive wear and is not stretched Sec : 8-2.1.3
(a-8)
ASME B30.8
3.11 Gudgeon pins do not have cracks, wear or distortion Sec : 8-2.1.3
(a-11)
ASME B30.8
Supports do not have any defects and have continued ability to sustain
3.12 Sec : 8-2.1.3
the imposed loads
(a-12)

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ASME B30.8
Hydraulic and pneumatic hoses, fittings and tubes are not damaged and
3.13 Sec : 8-2.1.3
not leaking
(a-13)
ASME B30.8
3.14 Hydraulic/Pneumatic pumps and motors are correctly functioning Sec : 8-2.1.3
(a-14)
ASME B30.8
Hydraulic/Pneumatic pumps and motors have no leaks, excess
3.15 Sec : 8-2.1.3
vibrations, unusual noises, loss of pressure or loss of speed
(a-14)
ASME B30.8
3.16 Hydraulic/Pneumatic valves and motors are correctly functioning Sec : 8-2.1.3
(a-15)
ASME B30.8
Hydraulic/Pneumatic valves and motors have no leaks, corrosion,
3.17 Sec : 8-2.1.3
excess vibrations, unusual noises or loss of pressure
(a-15)
ASME B30.8
Hydraulic/ Pneumatic cylinders do not leak (external and internal) at
3.18 Sec : 8-2.1.3
seals and welded joints or any other locations
(a-16)
Hydraulic/ Pneumatic cylinders are free of scores, dents or nicks on ASME B30.8
3.19 piston rods or cylinder barrels and loose/deformed rod eyes or Sec : 8-2.1.3
connecting joints (a-16)
ASME B30.8
Hydraulic filters are clean and free from debris such as rubber or metal
3.20 Sec : 8-2.1.3
particles
(a-17)
ASME B30.8
3.21 Boom cradle is available and can secure the boom if required Sec: 8-3.2.7
(b-2)

4 SWING COMPONENTS

Pins, bearings, shafts, gears, rollers, and locking devices are free of ASME B30.8
4.1
wear, cracks, and distortion Sec : 8-1.7.1

The swing mechanism is controlling the swing of the rated load under ASME B30.8
4.2
all operating conditions Sec : 8-1.7.1

Swing braking operates and capable of restrict the movement of the ASME B30.8
4.3
rotating structure Sec : 8-1.7.2 (a)

Swing brake locking device is provided and capable of locking the ASME B30.8
4.4
rotation of rotating structure Sec : 8-1.7.2 (a)

ASME B30.8
4.5 Swing brakes are adjustable to compensate for wear
Sec : 8-1.7.2 (d)

ASME B30.8
4.6 All swing moving parts are lubricated
Sec : 8-2.3.4 (a)

5 CABIN

Exhaust pipes are insulated and gases are properly discharged away ASME B30.8
5.1
from the operator's cab Sec : 8-1.10.5

A portable fire extinguishers are in place inside cab and outside ASME B30.8
5.2
machinery (minimum rating of 10 BC) Sec : 8-1.4.4 (a)

ASME B30.8
5.3 A tool box with basic maintenance tools is placed inside the cab
Sec : 8-1.4.4 (b)

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ASME B30.8
5.4 An audible warning device is in place and within reach of the operator
Sec : 8-1.4.4 (c)

The load moment indicator (LMI) is installed and properly working (if ASME B30.8
5.5
2720 kg or more) Sec : 8-1.4.3 (b)

ASME B30.8
5.6 The cab and operating enclosures have good housekeeping
Sec: 8-3.4.4

6 MACHINERY AND ELECTRICAL EQUIPMENT

The machinery and electrical equipment are located clear of deck ASME B30.8
6.1
loading areas Sec : 8-1.3.1 (a)

Work areas, companion ways and ladders are equipped with anti-slip ASME B30.8
6.2
surface materials Sec : 8-1.3.1 (b)

Electrical wiring and equipment are free of damages and of the ASME B30.8
6.3
specified type for shipboard Sec : 8-1.3.1 (c)

Manholes and hatches are not less than 15" x 22" (380 mm x 560 mm) ASME B30.8
6.4
and raised above the deck to prevent accidental entry of spilled liquids Sec : 8-1.3.3 (a)

7 HOOKS

ASME B30.10
7.1 Labeling and manufacturer data are available and legible
Sec : 10-1.8

ASME B30.10
7.2 Safe working load is clearly marked on the hook
Sec : 10-1.8

Hook is not bent or twisted


ASME B30.10
7.3 • Max. bending or twisting not to exceed 10 degrees from plane of
Sec : 10-1.10.5 (f)
unbent hook or as per manufacturer recommendations

Hook is not distorted in the throat opening ASME B30.10


7.4 • Max. allowable throat opening is 5% not to exceed 1∕4 in (6mm) or as Sec : 10-1.10.5
per manufacturer recommendations (g)
ASME B30.10
Maximum wear in the hook bowl is not exceeding 10% (compared to
7.5 Sec : 10-1.10.5
new hook) or as per manufacturer recommendations
(e)
ASME B30.10
7.6 Hook is not cracked, gouged or shows nicks Sec : 10-1.10.5
(d)
ASME B30.10
7.7 Hook can lock (if it is a self-locking hook) Sec : 10-1.10.5
(h)

Inoperative latch (if provided) — any damaged latch or malfunctioning ASME B30.10
7.8
latch that does not close the hook’s throat Sec : 10-1.10.5 (i)

REMARKS:

REFERENCE DOCUMENTS:
1- ASME B30.5 - 2021 Issue: Mobile & Locomotive Cranes
2- ASME B30.8 - 2020 Issue: Floating Cranes and Floating Derricks
3- ASME B30.10 - 2019 Issue: Hooks

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
FLOATING CRANES AND FLOATING DERRICKS SAIC-U-7009 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
4- SAES-B067 - 2020 Issue: Safety Identification and Safety Colors
5- SA GI 7.025 -2018 Issue: Heavy Equipment Operator and Rigger Testing and Certification
6- SA GI 7.030 - 2023 Issue: Inspection and Testing Requirements for Elevating/Lifting Equipment

Load Tested By (If Applicable):


Name, Signature, & Date:

□ Inspected □ Witnessed by 3rd Party Certified Inspector:


Name, Signature, Certificate No. & Company:

User Representative:
Name, Signature, & Date:

# Saudi Aramco: Company General Use Saudi Aramco: Company General Use