1 GENERAL REQUIREMENTS
ASME B30.23
1.1 Equipment documentation is available Sec: 23-1.2.1
(c-4)
ASME B30.23
1.2 Previous inspection reports are checked Sec: 23-1.2.1
(c-4)
GI 7.030
1.3 Daily pre-operational inspection checklists are checked (if applicable)
Para: 5.1.2
ASME B30.23
Preventive Maintenance is established and updated records are
1.4 Sec: 23-2.3.1
maintained
(a-1)
ASME B30.23
1.5 Equipment is operated by a qualified operator Sec: 23-3.1.2
(a)
ASME B30.23
Durable signs are installed at the operator’s station and on the outside of
1.6 Sec: 23-3.1.2
the crane warning that electrocution or serious bodily injury
(a)
A sign is posted warning the operator not to rely solely on any automatic G.I. 7.030
1.7
device as a substitute for safe operating practice Para: 5.6.2
ASME B30.23
Manufacturer name, address, serial number and model are clearly
1.8 Sec: 23-1.1.1
marked or tagged
(b-7-a)
ASME B30.23
Safe working load and number of persons are clearly marked on the work
1.9 Sec: 23-1.1.1
platform
(b-7-b)
ASME B30.23
1.10 Minimum design factor is 5, based on the stated platform rating. Sec: 23-1.1.1
(a-1)
2 INSPECTION POINTS
ASME B30.23
2.1 Platform rating is not less than 300 lb. (136 kg) Sec: 23-1.1.1
(b-1)
ASME B30.23
Platform top rail not less than 39 in. (990 mm) nor more than 45 in
2.2 Sec: 23-1.1.1
(1140 mm).
(b-2)
ASME B30.23
Anchorage points are suitable for attaching personnel fall protection
2.3 Sec: 23-1.1.1
device without failure
(b-3)
Hand railings are provided around the entire platform with the exception ASME B30.23
2.4 of any access gates or doors and have clearance of not less than 1.5 in. Sec: 23-1.1.1
(39 mm) between the railing and any other structure (b-4)
Floor is slip-resistant surface and have provisions to facilitate free ASME B30.23
2.5 drainage of liquids and have no opening that will allow sphere more than Sec: 23-1.1.1
0.5 in. (13 mm) (b-5)
ASME B30.23
Access systems (if installed) is equipped with positive acting device to
2.6 Sec: 23-1.1.1
restrain the access system from accidental opening.
(b-8)
ASME B30.23
Shackles (if used) in the suspension system shall be of a bolt type with
2.7 Sec: 23-1.1.1
cotter pin
(b-10-i)
REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
Rope or chain hoisting systems have an anti-two-block device ASME B30.23
2.8
installed. Sec: 23-1.2.2 (b)
ASME B30.23
2.12 Safety harness anchorage is fitted in the platform Sec: 23-3.2.1 (j-
3)
ASME B30.23
There are no loose nuts, bolts, missing, worn or damaged parts around
2.13 Sec: 23-1.1.1 (b-
the structure
6)
ASME B30.23
2.14 The equipment is free of defective and/or corroded members/joints Sec: 23-2.2.1
(a-3)
ASME B30.23
2.15 Working environment/condition is hazard free Sec: 23-2.2.1
(a-3)
REMARKS: This check list will be applied for Personnel Lifting Systems- ASME B30.23
REFERENCE DOCUMENTS:
1- ASME B30.23 - 2016 Issue: Personnel Lifting Systems
3- SA GI 7.027 -2016 Issue: Crane Suspended Personnel Platform (MANBASKET)Operations
4- SA GI 7.030 - 2023 Issue: Inspection and Testing Requirements for Elevating/Lifting Equipment
User Representative:
Name, Signature, & Date: