Operator Work Station Application Server(s) IntelliCENTER Software provides significant reduction in
(OWS) -Remote Access CIP – Simultaneously control, configure and collect troubleshooting time, allowing immediate issue identification, in many
The communication technology (Common Industrial Protocol) allows instances before equipment shuts down. Remote diagnostics reduces
for simultaneous control, configuration and data collection. No human interaction with the electrical equipment, improving safety for
resources are taken from the controllers and therefore no plant personnel. Early diagnostic and fast troubleshooting have
programming is required. The architecture provides concurrent significant, positive impact on overall system availability.
support for real time control and strategies specifically targeted at
predictive maintenance, asset performance management and overall
equipment efficiency.
Ethernet IP topology / resources
Standard EtherNet IP topology allows for any mix of star, tree, Stratix
ring and linear configuration. Media choices include copper, fiber Switch
and IP-67. Any device can be accessed from any location in CONTROLLER CONTROLLER
Process the system. There is no need to extend a second network to a
Logix5562 DC INTPUT DC OUTPUT
RUN I/O
POWER MODULE
ST 0 1 2 3 4 5 6 7 ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7 FLT 0 1 2 3 4 5 6 7
FORCE RS232
ST 8 9 10 11 12 13 14 15 ST 8 9 10 11 12 13 14 15 REWORK
BAT OK FLT 8 9 10 11 12 13 14 15 FLT 8 9 10 11 12 13 14 15
Automation System
V+
CAN_H
SHIELD
MS NS CAN_L
LNK V-
ETHERNET / IP
Stratix
100 BASE-T
Server (PASS)
Switch
CHANNEL 0
throughout the manufacturing and IT enterprise.
B
CH 0
B A
Domain
Controller
MCC network segment controls up to 45 motors. PowerFlex drives can be directly connected to the Ethernet IP
POWER RUN I/O ST 0 1 2 3 4 5 6 7 ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7 FLT 0 1 2 3 4 5 6 7
FORCE RS232
ST 8 9 10 11 12 13 14 15 ST 8 9 10 11 12 13 14 15
An individual ControlLogix controller can control connection to EtherNet/IP Scanner in the ControlLogix and main backbone or I/O downlinks. In this configuration the
POWER
STS
up to 10 MCC network segments, each at a CompactLogix controllers. All switches are connected to each drive‛s internal memory can be directly mapped into the
32mS RPI, without disturbing the Critical System Stratix other in a linear topology and then follow a star topology to the
B A
EtherNet/IP Network
PowerFlex
IMC devices in the CENTERLINE MCC are connected through an EtherNet/IP AC Drive
network via a 600V rated Ethernet cable capable of 100 Mbps. The combined
linear and star topology allow for individualized unit maintenance from removal
to re-insertion without disturbing the other IMC devices in the MCC. All IMC CONTROLLER CONTROLLER
devices are tested from the factory and with the IP Addresses and Subnet POWER
Logix5562
RUN
FORCE
BAT
I/O
RS232
OK
DC INTPUT
ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7
ST 8 9 10 11 12 13 14 15
FLT 8 9 10 11 12 13 14 15
DC OUTPUT
ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7
ST 8 9 10 11 12 13 14 15
FLT 8 9 10 11 12 13 14 15
POWER
Logix5562
RUN
FORCE
BAT
I/O
RS232
OK
DC INTPUT
ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7
ST 8 9 10 11 12 13 14 15
FLT 8 9 10 11 12 13 14 15
DC OUTPUT
ST 0 1 2 3 4 5 6 7
FLT 0 1 2 3 4 5 6 7
ST 8 9 10 11 12 13 14 15
FLT 8 9 10 11 12 13 14 15
Stratix
B A
Switch B A
NOTE: Ratings 200-240V • 0.37...11 kW • 0.5...15 Hp • 1.4...24 A • 0.37...18.5 kW • 0.5...25 Hp • 2.2...70 A • 0.37...75 kW • 0.5...100 Hp • 2.2...260 A • N/A
- For sleeve bearing motors with non-contact eddy current probe sensor pairs, we recommend two XM-120
modules per motor or one XM-162 module. Ratings 400-480V • 0.75...11 kW • 1...15 Hp • 1.7...19 A • 0.37...37 kW • 0.5...50 Hp • 1.1...72 A • 0.37...500 kW • 0.5...700 Hp • 1.1...875 A • 0.75...250 kW (2.1...456A) • 1...350 Hp
(2.1...415 A)
- For sleeve bearing motors that use case mounted velocity output sensors or for rolling element/anti-friction Ratings 500-600V • N/A • 0.37...37 kW • 0.5...50 Hp • 0.9...52 A • 0.75...132 kW • 1 - 150 Hp • 1.7...144 A • N/A
bearing motors, we recommend one XM-120 module per motor. One XM-160 can support up to three motors
using only case mounted sensors. Ratings 690V • N/A • 45...132 kW • 50...150 Hp • 1.7...144 A • N/A