You are on page 1of 2

4 03 0 B E ARING HO USING | I N S TA L L AT I O N AND

File No: 12.2003


Date: july 14, 2021
Supersedes: new
O P E R AT I N G I N S T R U C T I O N S Date: new

caution item description


Always disconnect power supply from motor before 44 Capscrew Hex Hd.
beginning service work. 60 Seat
62 Mechanical Seal
70 Shaft Sleeve
80 Impeller
warning:
83 Washer Impeller
Whenever any service work is to be performed on
84 Lockwasher (when fitted)
a pumping unit, disconnect the power source to
86 Capscrew Hex Hd.
the driver, lock it off and tag with the reason. Any
100 Casing
possibility of the unit starting while being serviced
101 Gasket
must be eliminated.
103 Washer
104 Capscrew Hex Hd.
Procedure to install the bearing housing to the 105 Pipe plug
pump 106 Support foot
108 Capscrew
43 44 104 103 40 105 110 Support foot (casing)
26
100 111 Washer
22
101 112 Capscrew Hex Hd.
21
80
113 Nut jam (when fitted)
32
114 Capscrew (when fitted)
29 70
121 Washer
23 84 122 Capscrew Hex Hd.
36
86 123 Washer
24 25
83 124 Capscrew Hex Hd.
27
105
111 112
108 1 Clean the shaft sleeve surface, ensuring the entire former
110 seal elastomeric residue has been removed. Inspect for
122
113 114 damage and replace if necessary. (See separate instructions,
121
124 file no. 6042.25, for removal of the motor shaft sleeve).
106
Inspect the water slinger and replace if damaged.
123 39 60 62
2 Make separate sub assembly of bearing housing, Adapter,
seal, Impeller and bearing support & fasten to the bearing
item description
housing.
21 Shaft
3 Fasten the adapter to bearing housing.
22 Bearing (Inboard)
4 Add seal to the shaft.
23 Bearing (Outboard)
5 Insert impeller.
24 Lockwasher
6 Fasten the impeller to the shaft using washer & impeller
25 Lock Nut
bolt.
26 Bearing Housing
27 Snap Ring
7 Add casing gasket to the casing.
29 Cap (O/B) 8 Lift the sub assembly carefully & fasten with casing.
32 Capscrew Hex Hd. 9 Fasten the bearing support to base.
36 Key Woodruff 10 Rotate the shaft and check for miss alignment if any.
39 Water Slinger 11 Observe if any undesired noises are coming from the
40 Adapter assembly by rotating the shaft.
43 Washer 12 Reconnect power and resume normal operations.
i n sta l l at ion & 4030
o p era t ing in str u ction s Bearing Housing

symptoms reasons Lubrication


Bearings overheat • Misalignment. Pump
• Insufficient cooling to stuffing box. Sealed Grease Bearings
• Badly packed stuffing box.
• If the pump is fitted with greased lubricated bearings, no
• Misalignment of pipework.
external lubrication is required.
• Dirt in bearings.
• These bearings are custom greased for general service
• Bearings too tight.
applications and sealed.
• Bearings badly installed.
Low bearing life • Misalignment.
• Dirt in bearings. Oil Lubricated Bearings
• Bearings too tight. • If the pump is fitted with oil lubricated bearings; use a non-
• Bearings badly installed. detergent oil equal to No.10 motor oil.
• Misalignment of pipework. • Prior to start up check to make sure the oil level is visible in
• Rotating element out of balance. the sight glass.
• Shaft bent. • Under normal operating conditions the oil should be
changed every year or 3000 hours as follows:
1 Drain the oil from the old bearing bracket.
2 Thoroughly flush the bearing bracket with Kerosene.
3 Refill the oil through the vent on top of the bracket until
the oil level is visible in the middle of the sight glass.
toronto
+1 416 755 2291

buffalo
+1 716 693 8813

droit wich spa


+44 8444 145 145

manchester
+44 8444 145 145

bangalore
+91 80 4906 3555

shanghai
for service related parts & kits
+86 21 5237 0909 Use ADEPT Select to quickly and easily select.
Visit adept.armstrongfluidtechnology.com to learn more