Ultrasonic Flowmeters

For Liquids and for Air

From Air to Oil


Reliable Flow Measurement

21A1-E-0006a
Innovative Solutions for Various Applications
Spool Piece Ultrasonic Flowmeter for Liquids
‧ High accuracy: ±0.2% of rate
‧ Easy-to-operate
‧ Low maintenance NEW
‧ Convenient configuration and data management from PC
Principle: transit time difference method with parallel three measuring paths *1

Applications
Introduction movie
Reduction of water use in plant utilities, flow
Read the QR code with
monitoring in filtration equipment, flow mea- your smartphone or tablet.
surement on two pipes, liquid level monitoring
in tanks

Clamp-on Ultrasonic Flowmeter for Liquids


‧ No piping work—cost saving
‧ Installation available without interrupting the plant operation
‧ Non-contact and low-maintenance sensor
‧ Wide selection
Principle: transit time difference method*2

Applications

Flow measurement of ultra-pure water in semiconductor manufacturing plants, paint


and coating material in painting process, water in air-conditioning systems, drainage

Ultrasonic Flowmeter for Air


‧ No projections inside pipe—no pressure loss
‧ Abundant applicable pipe diameters
‧ Tolerant to oil mist—No need for filter such as mist separator
Principle: transit time difference method*2

Applications

Visualization of the compressed air use, early detection of air leakage

Principle
*1: T ransit time difference method with parallel *2: Transit time difference method
three measuring paths Flow velocity: V = K ‧ (T2 - T1)
Sensor 1
πD2
Three parallel paths are arranged Pipe cross-sectional areas: A = A pair of sensors installed on
Sensor 4
at selected positions to reduce Path 1
the outside wall of the pipe,
the adverse effect of flow profile. Flow rate: Q = A ‧ V facing each other slantingly. The
By measuring the flow with the Path 2 sensors emit ultrasonic pulse in Flow
three paths simultaneously, and Pipe inner diameter :D turn, and detect the transit time
Path 3 Transit time with flow : T1
averaging them, the flowmeter difference of the pulse, by which
Transit time against flow : T2
obtains an accurate flow rate. Flow coefficient :K
the flow rate is calculated.

Sensor 2

2
Selection Guide for Liquid Applications
:best suitable :suitable ×:not applicable

Spool Clamp-on type


piece
flowmeter TIME DELTA-C TIME DELTA-C TIME DELTA-C M-Flow PW Portable type Duosonics
(FST) (FSV, FSS) (FSV, FSS) (FSV, FSS) (FLR, FSS) (FSC, FSS) (FSH, FSW)

Fluid

IP66 IP67 Advanced

Clean liquid with no air bubbles       


Sewage, drainage       
Viscous liquid       
Oil       
Corrosive liquid       
Polishing slurry Conditionally applicable 
Fibrous slurry Conditionally applicable 
Conditionally
Low-velocity fluid applicable      
Pulsating fluid × Conditionally applicable 
High-temperature fluid       ×
High-pressure fluid       
*Measurement may be unavailable depending on conditions.

Clamp-on Detectors for Liquid Applications


For pipe diameters from 13 mm to 6000 mm

FSSA FSSD FSSE FSSH

Model

Easy installation For small pipes For large pipes For high temperature
Applicable FLR FSC FSC FSC
transmitter
Model FSV FSV FSV FSV
Diameter (mm) 25 to 225 13 to 100 200 to 6000 50 to 400
Fluid temperature (°C) -20 to 100 -40 to 100 -40 to 80 -40 to 200

FSSC (extendable rail type)

Model

Normal (V method) Extended (V method) Separated (Z method)


Applicable
transmitter FSC, FLR, FSV
Model
Diameter (mm) 50 to 300 Up to 600 Up to 1200
Fluid temperature (°C) -40 to 120

3
Spool Piece Ultrasonic Flowmeter
for Liquid Applications [FST]
Three Pairs of Sensors Offer an Accuracy of ±0.2% of Rate
For Precise Control and Improved Efficiency
No Projections Inside Pipe — Low Maintenance

Pipe size: 100 A Pipe size: 80 A Pipe size: 50 A

Superior Bubble Resistance Improved Zero-Point Stability


Fuji Electric’s advanced anti-bubble measurement Achieved by a combination of the advanced circuit
technology reduces the interference to ensure design, the latest electronics, and innovative digital
accurate measurements. signal processing technology.

Signal averaging
Improved Sensitivity
The newly developed high-sensitivity sensors and
noise reduction technology result in improved
Air bubbles Air bubbles
signal-to-noise ratio.
Normal propagation Propagation interrupted
by bubbles
Measurement failure may occur.
Accepts Various Types of Fluid
FST can measure non-conductive fluids such as
By averaging a set of multiple measurements, precise oil, purified water, or a mixture, with temperature
signals can be obtained. ranging from -40°C to 150°C.

4
Backlit LCD and Front Panel Operation Convenient Configuration and
Data Management from PC
Front keys allow you to configure parameters, enter
piping conditions, or calculate sensor spacing, Parameter loader software, provided as standard,
without opening the cover. Measurement results allows parameter setting and measurement data
are shown on the 16-digit 2-line LCD in Japanese, acquisition on PC. RS-485 communication is optionally
English, German, French, or Spanish. Self-diagnosis available.
function tells you if an error occurs. Laptop

User can select which


value to show on each line
USB

Green at normal, red at error


*An RS232C to RS485 converter is required.
Waterproof keypad If your PC does not support the RS232C serial interface, a USB to
RS232C converter is also required.
LED-backlit LCD
Flexible Output Terminal
Equipped with terminals for insulated 4–20 mA DC
Selectable Panel Position analog output, pulse output, and alarm output.

You can select the most suitable panel position for


Reliability. Safety. Convenience.
your application.
Other useful functions include : zero point adjustment,
damping, low flow cut-off, alarm contact output, output
burnout, flow switch, total switch, unit selection, bi-
directional range, auto-switchable two range.
Page
Page
: Page
: Page
: :
TAG.
TAG.
No.
TAG.
No.
TAG.
No. No.
POS.
POS.
No.
POS.
No.
POS.
No. No.
Specifications
外外外
形外形形
図形図図図 Transit time difference method
OU
O TU
OTU
LOITU
LNITE
LNI ELNIEN E Principle Parallel 3-path
Vertical mounting Pipe size φ50 mm, φ80 mm, φ100 mm
Flange rating JIS10K/JIS20K, ANSI 150/300, DIN PN16/40
Accuracy ±0.2% of rate (flow velocity: 1 m/s to 10 m/s)
Fluid pressure Up to flange rating
ESC ENT
ESC ENT
ESC ENT
ESC ENT
Fluid temperature -40°C to 150°C
Measurement
Ultrasonic Flowmeter Ultrasonic Flowmeter Ultrasonic Flowmeter Ultrasonic Flowmeter

Flow velocity: 0 to ±0.3…±10 m/s


range
Flange: stainless steel 316L
Material Short pipe: stainless steel 316L
Output signal 4–20 mA DC, total pulse, alarm output
16-digit 2-line backlit LCD
Display 2-color LED (green: normal, red: at error)
Zero point adjustment, damping, low-flow cutoff, alarm,
Fuji Electric Co., Ltd.. They shall be neither reproduced, copied,
copied,
copied,
copied,
without
third party, nor used for the manufacturing purposes without
third party, nor used for the manufacturing purposes without
third party, nor used for the manufacturing purposes without

output burnout, output limit, bi-directional range, auto-


use of any
use of any
use of any
use of any
This material and the information herein is the property of
of
of
of

Functions matic two ranges, flow switch, total switch, preset total,
theproperty
property
property

AA AA A 11thBcode
BBB C Ccode
CC C D11th
DDcode
D D
be neither reproduced,
reproduced,
reproduced,
purposes

11th code B 11th data backup at power outage


theLtd..
theLtd..
theLtd..

the express written consent of Fuji Electric Co., Ltd..

Communication RS-485 (option)


Co.,
Fuji ElectricforCo.,
Fuji ElectricforCo.,
forthe
the
herein is the

* Indicates the flow direction.


Electricfor
manufacturing
herein is
herein is
neither
neither

Data backup at On nonvolatile memory


way whatsoever
wayofwhatsoever
wayofwhatsoever
any wayofwhatsoever

power outage
Fuji
be
be
information
information
information

Power supply volt- 100–240 V AC, 50/60 Hz


shall
shall
shall

EEE E
the

age
consent
consent
in consent
Ltd.. They
They
They
for
theany
theany
theany

ESC ENT
ESC ENT
ESC ENT
ESC ENT

Grounding Class D grounding with ground resistance of 100Ω or less


Ultrasonic Flowmeter Ultrasonic Flowmeter Ultrasonic Flowmeter Ultrasonic Flowmeter
Co., used

Low Maintenance
Ltd..
Ltd..
and in
and in
and in
written
written
written

Provided as standard, on power supply port and ana-


or disclosed
or disclosed
or disclosed
or disclosed
Co.,
Co.,
party, nor

Arrestor log output port


lent, material
material
material
thirdElectric
Electric
Electric
lent,express

the express
the express

Power consumption Approx. 20 VA


The lack of projections inside keeps the pipe almost
lent,
lent,
This
This
This
Fuji
Fuji
Fuji
the

Ambient temperature -40°C to 60°C


entirely
取付
取付
・配線方向
取付
・配線方向
取付
free from contamination, thereby reducing
・配線方向
・配線方向
Ambient humidity 90% RH or less
IP enclosure IP66
maintenance work.
形式12桁目
形式12桁目
形式12桁目内容内容内容内容
形式12桁目
Flow velocity: m/s
水平取付/下流方向
水平取付/下流方向
水平取付/下流方向
水平取付/下流方向 Unit Flow rate: L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s, m3/min,
A A A A
m3/h, m3/d, km3/d, Mm3/d
水平取付/上流方向
水平取付/上流方向
水平取付/上流方向
水平取付/上流方向
B B B B

水平取付/上流から見て右方向
水平取付/上流から見て右方向
水平取付/上流から見て右方向
水平取付/上流から見て右方向
C C C C

水平取付/上流から見て左方向
水平取付/上流から見て左方向
水平取付/上流から見て左方向
水平取付/上流から見て左方向
5
D D D D

垂直下→上/上流方向
垂直下→上/上流方向
垂直下→上/上流方向
垂直下→上/上流方向
E E E E
Clamp-on Ultrasonic Flowmeters
for Liquid Applications
No Piping Work—Cost Saving
Easy Installation Without Interrupting the Process
Non-Contact and Low Maintenance Sensor
Flow Transmitters

FSV FSV FLR FSC FSH

Hardly Affected by Fluid Pressure and Superior Bubble Resistance


Temperature
Fuji Electric’s advanced anti-bubble measurement
The sensors placed on upstream and downstream technology reduces the interference to ensure
emit ultrasonic pulse in turn, and detect the transit accurate measurements.
time difference of the pulse to calculate the flow
rate. Highly accurate measurement can be obtained
regardless of the type of fluid.
Signal averaging

Normal propagation Propagation interrupted by bubbles

Air bubbles Air bubbles

Fast Response Mode Delivers ≤ 0.2s Normal propagation Measurement failure may
occur.
Response Time
Allows you to take corrective actions quickly.

By averaging the results of 128 or 256


measurements, precise signals can be obtained.
Convenient Configuration and
Data Management from PC 12
12
Acceptable amount of
air bubbles

Parameter loader software, provided as standard, 10


allows parameter setting and measurement data 8
7.0 Advanced ABM system
acquisition on PC. 6
4.0
4 Conventional systems
1.5
2 1.2
0.4 1.0
0.03 0.02
RS485 (Modbus) [vol.%] 0 0.02
1.0 2.0 3.0 4.0 5.0
Flow velocity [m/s]
*Flowmeters indicate the volumetric flow rate which includes air bubbles.

6
Clamp-on Detectors for Liquid Applications
For pipe diameters from 13 mm to 6000 mm

Fluid Pipe inner diameter (mm)


Mounting Transmitter
Appearance Type temperature
method 13 25 50 100 200 250 300 400 600 1000 3000 6000 type
[°C]

FSSD -40 to 100 V 13 Px, P, M 100 FSC,FSV

FSSA -20 to 100 V 25 P, M 225 FLR,FSV

50 P, M 600
V
50 Px 300
FSC,FLR,
FSSC -40 to 120
FSV
200 P, M 1200
Z
200 Px 400

V 50 Px, P, M 250
FSSH -40 to 200 FSC,FSV
Z 150 Px, P, M 400

V 200 Px, P, M 3000


FSSE -40 to 80 FSC,FSV
Z 200 Px, P, M 6000

Mounting method : V method or Z method


Detector Detector
Px : PP, PVDF
Classification of
P : Plastic (PVC, etc.)
D

piping materials
M : Metallic piping (steel pipe, copper pipe, aluminum, etc.)
V method Z method

Real-Time Monitoring of Flow Profile Two Pipes Measurement by One Flowmeter


Useful for flow velocity analysis or laboratory tests You can obtain the average value, the total value,
*Duosonics (FSH) and portable type (FSC) only and the subtraction value.
*TIME DELTA-C (FSV-2) advanced type only

4–20 mA DC Analog Output


(2 points)
Each point can be allocated among:
① Path 1 flow rate ②Path 2 flow rate
③Average ④Total ⑤Subtraction Flow transmitter
Contact Pulse Output (4 points) (FSV)
Totaltotal flow rate, alarm, etc.
RS-485 (Modbus)

Detector (FSSC)

Signal cable

Pipe No. 1

Signal cable

Pipe No. 2
Portable type
Detector (FSS)

7
High Accuracy and Wide Measuring Range

TIME DELTA-C
Flow transmitter: FSV Detector: FSS

Features

High Accuracy: ±1.0% of Rate*


Flow transmitter (FSV)
*For details, refer to the data sheet. IP66
Detector (FSS)

Wide Range of Detectors for Pipes 13–6000 mm


Including the extendable detector for pipe diameters from 50 Specifications
mm to 1200 mm
Fluid temperature
Model Diameter (mm)
(°C)
Backlit LCD and Front Panel Operation FSSA 25 to 225 -20 to 100
Detector FSSC 50 to 1200 -40 to 120
Front keys allow you to configure parameters, enter piping FSSE 200 to 6000 -40 to 80
conditions, or calculate sensor spacing, without opening the FSSD 13 to 100 -40 to 100
cover. FSSH 50 to 400 -40 to 200
Measurement range -32…0…+32 m/s (minimum 0.3 m/s)
Instantaneous flow rate (8-digit numerals) Response time ≤ 0.2 s
Output signal 4–20 mA DC, pulse output, alarm output
Instantaneous flow velocity (8-digit numerals)
Communication RS-485 (Modbus) option
Accuracy ±1.0% of rate (depending on flow velocity and diameter)
Green at normal, red at error Power supply voltage 100–240 V AC or 20–30 V DC
IP enclosure IP66 or IP67
Waterproof keypad
Cable between detector
≤ 150 m
LED-backlit LCD and transmitter

Configurable Among Three Different Ways to Suit Your Application

TIME DELTA-C advanced type


Flow transmitter: FSV Detector: FSS

Select one of the following functions when you order. Flow transmitter (FSV)
Detector (FSS) IP67

1. Consumed Energy Calculation 2. S imultaneous Flow Measurement of


A function to obtain thermal energies exchanged via fluid Two Pipes with One Transmitter
used in air-conditioning systems. The transmitter calculates Allows cost reduction.
the consumed thermal energy based on the forward flow
temperature, the reverse flow temperature, and the flow rate.
3. Two Measuring Paths for One Pipe
Highly accurate measurement can be provided even if the
4–20 mA DC Analog Contact Pulse Output
Output (2 points) (4 points) flow is uneven.
① Flow rate Total energy, temp. alarm,
②C onsumed thermal mode switching, etc. Specifications
energy RS-485 (Modbus) Flow transmitter Consumed energy calculation version
(FSV) Output 4–20 mA DC: 2 points (flow rate, consumed energy)
Temperature sensor signal Contact output: 4 points (total energy, mode switching, temp. alarm, etc.)
(Pt100)
Two pipes measurement version
Output 4–20 mA DC: 2 points (path1, path2, average, total, subtraction)
TS: forward flow temperature signal Contact output: 4 points (flow rate total pulse, instantaneous flow rate pulse, alarm, etc.)

Heat source Temperature


sensor Detector (FSS) Load Two-path for one pipe version
(Pt100) Output 4–20 mA DC: 2 points (path1, path2, average)
signal Contact output: 4 points (flow rate total pulse, instantaneous flow rate pulse, alarm, etc.)

TR: return flow temperature Q: flow rate Detector FSS φ13 mm to 6000 mm
Measurement range -32…0…+32 m/s (minimum 0.3 m/s)
Accuracy ±1.0 % of rate (depending on flow velocity and diameter)
Power supply voltage 100–240 V AC, 50/60 Hz

8
Compact and Lightweight

M-Flow PW
Flow transmitter: FLR Detector: FSS

Detector (FSSC) Detector (FSSA) Flow transmitter (FLR)

Features

Backlit LCD and Front Panel Operation Analog and Digital Communication
Front keys allow you to configure parameters, enter piping Equipped with an analog output terminal, two transistor contacts,
conditions, or calculate sensor spacing, without opening the and an RS-485 communication interface.
cover.
4–20 mA analog output,
1 point, insulated
Instantaneous flow rate (8-digit numerals) maximum load resistance: 600Ω
Input signals
Instantaneous flow velocity (8-digit numerals) from detector Transistor contact, 2 points, insulated
Frequency: 100 P/s max
Pulse width: 5–1000 ms
Green at normal, red at error RS-485 signal, insulated
Power supply voltage
Waterproof keypad (With arrester, 100–240 V AC or 20–30 V DC)
LED-backlit LCD

Compact Design Specifications


Fluid temperature
Model Diameter (mm)
W13 × H14 × D6.9 mm, only a quarter in volume of conventional (°C)
Detector
models. It can be easily installed in a small space. FSSA 25 to 225 -20 to 100
FSSC 50 to 1200 -40 to 120
Measurement range -10…0…10 m/s (minimum 0.3 m/s)
Response time ≤ 0.2 s
Output signal 4–20 mA DC, pulse output, alarm output
Communication RS-485 (Modbus) option
Accuracy ±1.5% of rate (1.0% of rate is available on request)
140mm
Power supply voltage 100–240 V AC or 20–30 V DC
IP enclosure IP65
Cable between detector
≤ 60 m
and transmitter

Mass: approx 0.8kg


130mm

Mounting method: wall or pipe mounting

Example of system configuration


Flow transmiter (Type: FLR)

Signal cable (Type: FLY)

RS-485
Detector (Type: FSS) Communication

Paperless recorder (Type: PHF)


4 to 20mA DC
< V method >
Power Supply
Detector (Type: FSS) Pulse output Integrator

Contact output
Relay

< Z method >

9
Portable Type
Flow transmitter: FSC Detector: FSS or FSD

Detector (FSS) Flow transmitter (FSC)


Features

Easy Measurement Anytime and Anywhere Consumed Energy Calculation


Handy and battery-driven design allows you to take measurement A function to obtain thermal energies exchanged via fluid
when and where needed. used in air-conditioning systems. The transmitter calculates
the consumed thermal energy based on the forward flow
temperature, the return flow temperature, and the flow rate.

4–20 mA DC output (1 point)


Consumed thermal energy
q = K ‧ Q ‧(T1 -T2)
Flow
transmitter K: heat coefficient
(K for heating = 4.123)
Temperature sensor

T1: Forward flow temperature


Flow
source

Load
transmitter
Heat

Detector (FSS)
Temperature sensor

T2: Return flow temperature Q: flow rate

Real-Time Monitoring of Flow Profile Data Management on PC


Using the flow transmitter FSC in combination with the optional Data in SD card can be transmitted to your PC through a USB
pulse doppler detector (FSD) enables real-time monitoring of cable.
flow profile (option).
Loader software provided
Parameter setting screen

Flow trend screen

Flow profile screen

Flow profile indication

Carrying Case

The dedicated case accommodates all the necessary equipment


including:

● Flow transmitter ● AC power adapter


● Detector (FSSC or FSSD) ● Power cable
● Acoustic coupler (silicone grease) ● Mounting belt
● Signal cable ● USB cable
● Analog I/O cable ● CD-ROM (instruction manual,
● Strap parameter loader software)

Carrying case
10
Data Storage on SD Card Easy-to-Mount Detector
The transmitter automatically saves the measured data on SD Mounting detector requires no tools. You can start measurement
memory card at user-specified cycle. You can also send the anytime.
data through USB port to your PC.

For example, a 512 MB memory card can store the data of two
years' worth (at a data save cycles of 30 s, 14 kinds of data).
SD card up to 8 GB can be used.

Cover

USB port

SD memory card slot

Multilingual Display 12
‌ Hours of Continuous Operation
with Built-in Battery
FSC can serve long hours of outdoor measurement.

On-Site Printing
You can print out the measured data or screenshot by the
dedicated printer (option).

English Chinese

Easy-to-See LCD

Specifications
Fluid temperature
Model Diameter (mm)
(°C)
FSSD 13 to 100 -40 to 100
Detector
FSSC 50 to 1200 -40 to 120
FSSH 50 to 400 -40 to 200
FSSE 200 to 6000 -40 to 80
Received waveform Logger data Measurement range -32…0…32 m/s (minimum 0.3 m/s)
Response time ≤1s
Analog output 4–20 mA DC
Analog input 4–20 mA DC/1–5 V DC
Accuracy ±1.0 % of rate (depending on flow velocity)
Power supply voltage Built-in rechargeable battery (battery life: 12 hours)
SD card (option) 512 MB (stores 2 years’ worth data)
Others Parameter loader software (provided as standard)
Option Flow velocity profile display, printer

11
Hybrid type

Duosonics
Flow transmitter: FSH Detector: FSW

Detector (FSW) Flow transmitter (FSH)


Features

High Accuracy: ±0.5% to ±1.0% of Rate Real-Time Monitoring of Flow Profile


Sensor 1
±0.5% of rate in the pulse doppler method By connecting FSH with PC, you can monitor the flow profile in
Flow
±1.0% of rate in the transit time method real-time (option).
Air bubbles
Reflection

High-Speed Response Sensor 2

Flow velocity Sensor 2 Sensor 1


0.2s (Pulse Doppler method):
0.5s (Transit time method)
Pipe wall Center Pipe wall

Hybrid Technology
FSH switches between the pulse doppler method and the transit
time difference method according to the fluid being measured.
This enables FSH to measure a wide range of fluid, including
fluid which contains air bubbles or particles.

[Pulse doppler method] [Transit time method]


Sensor 1 Sensor 1

Flow Flow
Air bubbles
Reflection

Sensor 2 Sensor 2

Automatic switching
Receive Send
Flow velocity Sensor 2 Sensor 1 according to
Sensor 2 → sensor 1
flow conditions
Sensor 1 → sensor 2
Pipe wall Center Pipe wall Transit time difference

The frequency of ultrasonic pulses reflected by air


bubbles or solid particles changes according to the The sensors placed on upstream and downstream
flow velocity. The pulse doppler flowmeter uses this emit ultrasonic pulse in turn, and detect the transit
frequency shift to determine the flow profile and flow time difference of the pulse to calculate the flow rate.
rate.

Applications Specifications
• Yogurt, Dressing, Juice with Pulp Fluid temperature
Model Diameter (mm)
• Sugar Liquid, Milk 1
Sensor
(°C)
• Crude Oil FSWS12 40 to 200 -40 to 100
Flow Detector
• Wastewater/Sewage Monitoring FSWS21 100 to 400 -40 to 80
FSWS40 200 to 500 -40 to 80
• Paint
FSWS50 500 to 1000 -40 to 80
• …and other Challenging Industrial Applications.
Sensor 2
Measurement range -4…0…+32 m/s (minimum 0.3 m/s)
Response time ≤ 0.2 s
Receive Send
Sensor 2 → sensor 1 Output signal 4–20 mA DC, pulse output, alarm output
Communication RS-485 or RS-232C
Sensor 1 → sensor 2
Accuracy ±0.5% to ±1.0% of rate
Transit time difference
Power supply voltage 100–240 V AC or 20–30 V DC
IP enclosure IP67
Cable between detector
≤ 150 m
and transmitter

12
Ideal for Compressor Control

Ultrasonic Flowmeter for Air


Non-Intrusive Design Free From Pressure Loss
For Pipe Diameters from 25 mm to 200 mm
No Need for Oil Mist Separator

No Energy Loss Flow rate Conversion


Non-intrusive ultrasonic sensor causes no pressure Measured flow rate can be converted into a flow
loss rate under normal conditions of a temperature of 0
degree C (273.15 K) and an absolute pressure of 1
Tolerant to Oil Mist atm or user-defined conditions.

With no moving parts, FWD is robust, and requires


Bi-Directional Flow Measurement
no filters.
FWD can measure the air transfered between
Battery-Powered Version Available facilities, and the air flow in loop piping system.

The version equipped with a lithium-ion battery


(10-year life) greatly lightens the installation work.

Product Variations
FWD

For small diameter pipes For medium diameter pipes For large pipes

Diameter: Diameter: Diameter:


25 mm, 32 mm 40, 50, 65, 80 mm 100, 150, 200 mm
Process Connection: Process Connection: Process Connection:
ø25 mm: Rc1 ‌Wafer (between JIS10K flange
ø32 mm: Rc1-1/4 JIS10K flanges)

Specifications
Model FWD Diameter Range Accuracy
Pipe diameter (mm) 25, 32, 40, 50, 65, 80, 100, 150, 200 (mm) (m3/h) ±2.0% of rate ±5.0% of rate
Power supply 24 V DC ±10% or built-in lithium-ion battery 50 ±2.5–150 ±15–150 m3/h ±2.5–15 m3/h
voltage (battery life: approx. 10 years under the temperature of 20°C) Range ±4–240 ±24–240 m /h ±4–24 m3/h
65 3
(actual flow rate)
Target fluid Air (mainly factory air) or N2 (pipe diameter 25–80 mm) 80 ±5–300 ±30–300 m3/h ±5–30 m3/h
Accuracy
Fluid temperature -10°C to 60°C, RH 90% or less 100 ±10–500 ±50–500 m3/h ±10–50 m3/h
150 ±24–1200 ±120–1200 m3/h ±24–120 m3/h
Operating pressure <1 MPa (gauge pressure)
200 ±40–2000 ±200–2000 m /h
3
±40–200 m3/h
Diameter Range Accuracy
4–20 mA DC, pulse output (2 points)
Range (mm) (m3/h) ±2.0% of rate ±5.0% of rate Output signal
* Unavailable for battery-powered version.
(actual flow rate) 25 ±0.6–35 ±3.5–35 m /h3
±0.6–3.5 m /h
3
Straight run ø25 mm and 32 mm: ≥20D on inlet side and ≥5D on outlet side
Accuracy 32 ±1.1–65 ±6.5–65 m3/h ±1.1–6.5 m3/h requirements ø40–200 mm: ≥10D on inlet side and ≥5D on outlet side
40 ±1.3–80 ±8–80 m3/h ±1.3–8 m3/h Installation location Indoor or outdoor (IP64 equivalent)

13
Applications
[Spool Piece Ultrasonic Flowmeter]

Reduction of Water Used in Plant Utilities


Visualization of water use

Amount of water used


Visual depiction of a facility’s water
use results in more effective Building C

management of water consumption.


Main pipe Building B

0
0

13 0

14 0

15 0

16 0

17 0

18 0
0
12 0
:0
:0

:0

:0

:0

:0

:0

:0

:0

:0
:0
8
9
10

11
Building A Building A Building B Building C

Spool piece Ultrasonic Flowmeter (FST)

[Recommended Model: TIME DELTA-C]

For Large Diameter Pipes up to 6000 mm Flow transmitter


(FSV)
The price of clamp-on ultrasonic Detector
flowmeters is stable regardless of (FSSE)
Flow transmitter
pipe diameters, and lower than that (FSV)
of electromagnetic flowmeters if the Detector
(FSSD) 6000 mm
pipe diameter is 200 mm or larger.

13 mm

[Recommended Model: TIME DELTA-C]

Paint Flow Measurement Flow transmitter


(FSV)
Suitable for high viscosity Flow transmitter
fluids such as paint or coating (FSV)
Paint Detector
materials. (red)

Paint Detector
(blue)

Paint Detector
(yellow)

Flow transmitter
(FSV)

[TIME DELTA-C Advanced]

Drainage Monitoring 4–20 mA analog output (2 pt)


(total, subtraction)
Flow transmitter (FSV)
Measures the flow rates of
Digital output (4 pt)
two separate pipes, and Detector (FSSC) (total pulse, etc.)

calculates the total value and


the subtracted value. Facility A

Facility B

Detector (FSSC)

14
[TIME DELTA-C Advanced]

Energy Consumption in Air-Conditioning Systems


4–20 mA DC Analog
Calculates the thermal energy Output (2 points)
received and sent with liquid Temperature Flow transmitter ① Flow rate
sensor (FSV) ②C onsumed thermal
(Pt100)
in air-conditioning system. energy

TS: forward flow temperature


Contact Pulse Output
(4 points)
Heat source Temperature Load T
 otal energy, temp.
sensor Detector (FSS)
(Pt100) alarm, mode switching,
etc.
TR: return flow temperature Q: flow rate RS-485 (Modbus)

[Recommended Model: M-Flow PW]

Ultra-pure water
Water Purifying System in

manufacturing equipment
Semiconductor Industry

Semiconductor
Electromagnetic
Non-contact sensor can prevent the flowmeter
purified water from being affected Purified water flow measurement

by metallic ions.
Raw water Flow transmitter
(FLR)
Detector
(FSSA)

[Duosonics] [Recommended Model: M-Flow PW]

Cooking Oil Production Line Corrosive Fluid


Lower maintenance compared to mechanical Ultrasonic flowmeters can take measurement
flowmeters or Coriolis flowmeters on glass, metallic, and plastic pipes.

Flow transmitter Flow transmitter (FLR)


(FSH)
Detector

Tank Strong alkali


Strong acid
Detector Filler

[Duosonics] [Ultrasonic Flowmeter for Air]

Mayonnaise and Dressing Air Leakage Monitoring


Even a high viscosity and low velocity fluid can Detects the air leakage by operating a
be measured. compressor with valves closed
Air valve
Flow transmitter
(FSH)

Detector

Mayonnaise
Dressing
Compressor Ultrasonic
Flowmeter for Air
(FWD)

15
Specifications
[For liquid] Clamp-on
[For liquid]
TIME DELTA-C [For air]
Spool piece TIME DELTA-C M-Flow PW Portable type Duosonics
advanced type
Flow transmitter FSV FSV FLR FSC FSH
FST FWD
Detector FSS FSS FSS FSS FSW

Appearance

Pulse doppler + Transit time


Principle Transit time difference
Transit time difference difference
Bubble resistance       —
FSSA FSSA FSSA FSSD FSWS12
25–225 mm 25–225 mm 25–225 mm 13–100 mm 40–200 mm
(-20°C to 100°C) (-20°C to 100°C) (-20°C to 100°C) (-40°C to 100°C) (-40°C to 100°C)
FSSD FSSD FSSD FSSD FSWS21 25 mm
50–1200 mm 50–1200 mm 50–1200 mm 50–1200 mm 100–400 mm 32 mm
50 mm (-40°C to 120°C) (-40°C to 120°C) (-40°C to 120°C) (-40°C to 120°C) (-40°C to 80°C) 40 mm
80 mm FSSE FSSE FSSE FSWS40 50 mm
Pipe size 65 mm
100 mm 200–6000 mm 200–6000 mm — 200–6000 mm 200–500 mm
(Fluid temperature) (-40°C to 80 mm
(-40°C to 80°C) (-40°C to 80°C) (-40°C to 80°C) (-40°C to 80°C) 100 mm
150°C) FSSD FSSD FSSH FSWS50 150 mm
13–100 mm 13–100 mm — 50–400 mm 500–1000 mm 200 mm
(-40°C to 100°C) (-40°C to 100°C) (-40°C to 200°C) (-40°C to 80°C) (-10°C to 60°C)
FSSH FSSH
50–400 mm 50–400 mm — — —
(-40°C to 200°C) (-40°C to 200°C)
±4 m/s (0.3 m/s min.)
Measurement ±10 m/s ±32 m/s ±10 m/s ±32 m/s ±32 m/s (0.3 m/s min.) ±2000 m3/h
range (0.3 m/s min.) (0.3 m/s min.) (0.3 m/s min.) (0.3 m/s min.) in transit time difference (0.6 m3/h min.)
method
Number of path 3 (in parallel) 1 1 or 2 1 1 1 or 2 1
Consumed energy — —  —  (Temperature sensor and — —
calculation (RTD is not provided) signal converter are not provided)

Response time 1.2 s ≤ 0.2 s ≤1s ≤ 0.2 s ≤ 0.5 s


(Pulse doppler method)
4–20 mA output       
Pulse output     —  
Alarm output     —  
Communication RS-485 SD card, USB port RS-485/RS-232C —
±1.5% of rate ±0.5% to
Accuracy ±0.2% of rate ±1.0% of rate (±1.0% of rate ±1.0% of rate ±2.0% of rate
version available) ±1.0% of rate
100–240 V AC, 100–240 V AC, 100–240 V AC, 100–240 V AC, Lithium-ion
Power supply 100–240 V AC, 100–240 V AC
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz battery
voltage 50/60 Hz 50/60Hz
or 20–30 V DC or 20–30 V DC Built-in battery or 20–30 V DC or 24 V DC
Cable between
Not required ≤ 150 m ≤ 60 m ≤ 150 m Not required
detector and transmitter
Character LCD Graphic LCD Graphic LCD
Display Character LCD
with back light with back light with back light
Transmitter dimensions
— 170 × 142 × 70 240 × 247 × 134 140 × 137 × 68 210 × 120 × 65 240 × 247 × 134 —
H × W × D (in mm)
Transmitter weight 10.5 kg–23.5 kg 1.5 kg 5.0 kg 0.8 kg 1.0 kg 5.0 kg 1.1 kg–24.1 kg
:best suitable :suitable

Find out more about our ultrasonic flowmeters.

Ultrasonic Flowmeters - Fuji Electric


https://www.fujielectric.com/products/instruments/products/flow_ultra/top.html

Caution on Safety
Before using products in this catalog, be sure to read their instruction manuals.

Global Sales Section


Instrumentation & Sensors Planning Dept.
1, Fuji-machi, Hino-city, Tokyo 191-8502, Japan
http://www.fujielectric.com
Phone: +81-42-514-8930 Fax: +81-42-583-8275
http://www.fujielectric.com/products/instruments/

Information in this catalog is subject to change without notice. Printed in Japan 2017-4/5FOLS