You are on page 1of 23

Project plan

TAFE

05-03-2021

1
TAFE, 05-03-2021
Table of contents
Overview .......................................................................................................................... 3
Segment 1 ....................................................................................................................... 5
Segment 2 ....................................................................................................................... 9
Segment 3 ..................................................................................................................... 13
Segment 4 ..................................................................................................................... 17
Segment 5 ..................................................................................................................... 21
Disclaimer ...................................................................................................................... 23

2
TAFE, 05-03-2021
Overview
Roof specification
Country: Portugal
Wind zone: NONE
Terrain category: II
Air density: 1.25 kg/m3
Wind pressure: 1,071.76 N/m2
Roof pitch: 20°
Roofing material: Steel
Roof area: 10,999.79 m2
Roof height: 10.0 m
Segment count: 99
System specification
Panel model: Electrominho 340Wp
Panel dimensions: 1689mm x 996mm x 35 mm
Panel weight: 18.70 kg
Panel power: 0.340 kWp
Panel count: 937
Total power: 318.580 kWp
Bill of materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 2072
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 2072
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 396
1008069 ClickFit EVO bit torx 30 2
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 8288

3
TAFE, 05-03-2021
Segments

Static roof load


Total weight 17,848.60 kg
Roof area (gross) 10,999.79 m²
System area (projected area) 1,595.25 m²
Average load over system area 11.19 kg/m²
Average load over roof area 1.62 kg/m²

4
TAFE, 05-03-2021
Segment 1
System specification
Panel count: 8
Total power: 2.720 kWp
Orientation: Landscape
Rail system: Vertical

5
TAFE, 05-03-2021
6
TAFE, 05-03-2021
Fixation plan

Units are in mm

7
TAFE, 05-03-2021
Materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 18
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 18
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 4
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 72
Static segment load
Weight panels 149 Kg
Weight system 2 Kg
Total weight 152 Kg
System Area 13.62 m²
Average roof load over system area 11.19 Kg/m²
*Irregularities in the roof can cause deviating point pressures

8
TAFE, 05-03-2021
Segment 2
System specification
Panel count: 10
Total power: 3.400 kWp
Orientation: Landscape
Rail system: Vertical

9
TAFE, 05-03-2021
10
TAFE, 05-03-2021
Fixation plan

Units are in mm

11
TAFE, 05-03-2021
Materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 22
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 22
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 4
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 88
Static segment load
Weight panels 187 Kg
Weight system 3 Kg
Total weight 190 Kg
System Area 17.03 m²
Average roof load over system area 11.19 Kg/m²
*Irregularities in the roof can cause deviating point pressures

12
TAFE, 05-03-2021
Segment 3
System specification
Panel count: 7
Total power: 2.380 kWp
Orientation: Landscape
Rail system: Vertical

13
TAFE, 05-03-2021
14
TAFE, 05-03-2021
Fixation plan

Units are in mm

15
TAFE, 05-03-2021
Materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 16
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 16
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 4
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 64
Static segment load
Weight panels 130 Kg
Weight system 2 Kg
Total weight 133 Kg
System Area 11.92 m²
Average roof load over system area 11.20 Kg/m²
*Irregularities in the roof can cause deviating point pressures

16
TAFE, 05-03-2021
Segment 4
System specification
Panel count: 6
Total power: 2.040 kWp
Orientation: Landscape
Rail system: Vertical

17
TAFE, 05-03-2021
18
TAFE, 05-03-2021
Fixation plan

Units are in mm

19
TAFE, 05-03-2021
Materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 14
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 14
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 4
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 56
Static segment load
Weight panels 112 Kg
Weight system 2 Kg
Total weight 114 Kg
System Area 10.22 m²
Average roof load over system area 11.20 Kg/m²
*Irregularities in the roof can cause deviating point pressures

20
TAFE, 05-03-2021
Segment 5
System specification
Panel count: 1
Total power: 0.340 kWp
Orientation: Landscape
Rail system: Vertical

21
TAFE, 05-03-2021
Fixation plan

Units are in mm
Materials
Article number Description Amount
1008020 ClickFit EVO module clamp universal grey 4
1008048 ClickFit EVO mounting profile trapezoidal metal roof landscape 4
1008065 ClickFit EVO end clamp support grey for trapezoidal metal roofs 4
1008080 Self-tapping sheet metal screw 6,0x25mm torx 30 16
Static segment load
Weight panels 18 Kg
Weight system 0 Kg
Total weight 19 Kg
System Area 1.70 m²
Average roof load over system area 11.38 Kg/m²
*Irregularities in the roof can cause deviating point pressures

22
TAFE, 05-03-2021
Disclaimer
The installation of a PV system, or to an existing building, the hitherto existing building loads
(eg snow / wind,) Or changing the building constructions. To avoid personal injury and / or
property damage, it is necessary static calculations of the existing building to be reviewed by
a qualified technician. Here one must observe the current regulations and in particular the
NEN6702, NEN7250, NEN1991010104 A1 + C2 / NB. It does not check the static calculation
of the building, it can in the worst case, lead to failure of the roof load-bearing structure of the
building. Consultation with the insurer is required in the event of structural changes. Among
others, the following should be considered controlled architectural and good: The occurring
charges as a result of the additional weight of the complete PV system on the building. The
occurring charges as a result of the changed geometry of the roof on the building. The
occurring charges as a result of the dynamic wind pressure and possible accumulation of
precipitation on the building. The loads occurring during installation on the building, roofing
and insulation. The compatibility of the insulation and roofing material at the location of the
contact points of the supporting structure of the long-term PV-system as a result of the
pressure point. The compatibility of the roofing material in combination with the support
structure at the location of the contact points. The effect of thermal performance of the
building and the PV system on each other. The effect of any movement and vibrations of the
roof and the PV system on each other. Despite the fact that the calculations are carried out
carefully in the software, no rights can be derived. Prices in the software are indicative and
may change due to possibly rising commodity prices. The drawing an d the dimensions in the
software are indicative, no rights can be derived.

23
TAFE, 05-03-2021

You might also like