(DATE) (REFER NOTE 2)

WHERE MIN 1200 DDA


COMPLIANT PATH WIDTH IS NOT
(SIGNATURE)

MIN. 1200
EXISTING FOOTPATH ACHIEVABLE, REAR FACING
SHELTER MAY BE CONSIDERED
200
(MIN.)
SHELTER STRUCTURE SHELTER ROOFLINE

(REFER NOTE 4
(BLOCK LETTERS)

GRADIENT BETWEEN
1:100 TO 1:40
Certified By:

0
120
M IN .

300 MIN.

(REFER NOTE 3)
MIN. 1200

800 MIN
300±10

600±50

FACE OF KERB

2000 MIN.
STANDARD SLEEVE
TO SUIT 50NB POLE
(REFER TO DRAWING
STD_S0062).

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE NOTED.

2. DRAWINGS STD_S0064 - STD_S0081 SHALL BE READ IN ASSOCIATION WITH EACH OTHER.

3. IF BUSES CAN ACCESS THE BUS STOP IN A STRAIGHT MOTION (I.E NOT NEEDING TO PULL IN, SUCH AS INTO AN INDENTED BAY OR SWING IN AFTER PARKING), THE GAP BETWEEN THE ROOF AND THE FACE OF KERB
CAN BE REDUCED (FROM 800mm) TO 600mm.

4. ALL/ANY ENCROACHMENT INTO/OVER FOOTPATH CAN ONLY OCCUR WITH COUNCIL AGREEMENT.

5. DIMENSIONS MUST BE A MINIMUM 300 BETWEEN TACTILE EDGE AND POLE EDGE PREFERABLY BELOW 400, OR AS APPROVED BY DOT-BUS INFRASTRUCTURE TEAM.
ORGANISATION AUTHORISED BY DATE
DOT

<5123456.123>
<123456.123>

<5123456.123>
<123456.123>
<Enter the up track PASS
<EnterIDZ55>
<MGA the
#>down track PASS ID #>

Consultant Drawn By Designed By


.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
This drawing has been prepared by, or compiled from
information provided by, persons other than PTV. To the
maximum extent permissible by law, PTV takes no
STRUCTURAL JH JG
STANDARD DRAWING
23/04/19 12:00:00 PM

responsibility for, and makes no representations in relation to, Checked By


. . . . . . . . . the completeness, accuracy or quality of any information Ind. Review
contained in this drawing. Each user of this drawing releases
. . . . . . . . . PTV from all and any loss, damage, cost, expense or BUS STOP FOR A SITE WITH A SHELTERFile Name JG RQ
liability in relation to the use of, or any reliance on, this
TOMKINSON . D 11/10/21 AMENDMENTS AS PER DOT COMMENTS OB JH
. MM
. JH
.
drawing or the information contained in it. CLOSE TO THE BUS FLAG POLE STD_S0070_REVA.DWG Approved Approval Date
TOMKINSON . C 20/01/20 AS PER PTV COMMENTS JG JG
. RQ
. JG Franchisee / Lessee (DOWNSTREAM OF FLAG) - FORWARD FACING Sheet No.
TOMKINSON . B 26/07/19 .AS PER PTV COMMENTS JG JG RQ
. JG
All written dimensions take precedence over scaled
dimensions. Up Location Down Location Datum
1 1 of JG
Drawing Number
08/05/19
Revision
TOMKINSON . A 08/05/19 AS SUBMITTED TO PTV JG JG RQ
. JG In Serv.
Revised By
.
In Serv Rev. Date Description Designed Checked Ind. Review Approved
This drawing is provided only for the information of the East. .
person or organisation to whom PTV provides it. It may
not be provided to, or used by, any other person without North..
PTV's prior written consent. ID# .
East. .
North..
ID# .
.
Scale
1:25
.
Sheet Size
A3
STD_S0070 D