Star (star point or neutral point ကို body နဲ. Earth ခ်ထား earth neutral) ဘဃ္လသ
ို ိ
Star (star point or neutral point ကို body နဲ. Earth မခ်ထား insulated neutral system) manual/drawing
Check clamping
Check Phase sequence indicator lamp
Check volt meter frequency meter
Check isolating switch
Check breaker contact
Check fuse
Star (star point or neutral point ကို body နဲ. Earth ခ်ထား earth neutral)
Star (star point or neutral point ကို body နဲ. Earth မခ်ထား insulated neutral system)
Earth နဲ. Neutral ဘာ ကြာလည္း
Neutral ဆိတ
ု ာ source မ load ကို ဖတ္ source ကိူ normal return line/circuit complete
DEAD
Multi meter = α
Digital meter = OL
Multi meter = 0
Digital meter =
MEASURE THE
INSULATION
RESISTANCE
An open-circuit fault as due to break in the conductor so that current cannot flow
An earth fault is due to a break in the insulation, allowing the conductor to touch
metal frame.
A short-circuit fault is due to a double break in the insulation, allowing both
conductor (of different potential) to be connected thereby resulting in a very large
current bypasses or short-circuits the load.
Earth fault
440 V
220/110 V
24 V DC
There are three earth lamps which are equal brightness if there is no earth fault.
Location of earth fault can be traced by switching off individual branch circuit breaker
once at a time.
When branch circuit with fault is switch off, dark lamp will become normal brightness and
all three lamp burn with equal brightness again.
Earth မိရင်ဘာလိချက်
့ ချင်း action ယ ရဒါလည်း
Increase ampere
Causing over heating
Finally, will cause burn out
Generator will increase load
If there is already an earth fault on one phase, the remaining phases are potentially more
dangerous.
If another earth fault occurs on another phase, a short circuit will occur through the hull
of the ship tripping the essential services.
FIND Earth fault….Panel board inlet breaker carried open one by one check indicator lamp
Reason for carrying out insulation tests
Safety is provided by
Proper ventilation
Prevention of heat source for ignition
Ventilation
Necked light /No smoking Cables of adequate size and they are well connected
Never place Emergency Switchboard in this room
No switchboard in batter room Use insulated spanner and plastic jug for distilled
MSDS
1. Trickle Charging(counter)
2. Float Charging
3. Equalizing Charging(counter)
4. Rapid Charge or Boot Charging or Quick Charging (Emergency
Charge)
Trickle Charge
Disconnect from load keep charging with small current(for stand by of
Emergency)
Power failure, battery auto connect the load, supply power
Used for Emergency equipment 24 volt ဆိပ
ု ါဆို. Battery က loadနဲ. မခ်ိတေ
္ သးပဲ
Control by relay small current နဲ. 24 volt ေရာက်ေAာင အ မဲတမ်း
Special extended normal charging positive plate ရှိတယ်negative plate ရှိတယ် <ကာလာရင