Professional Documents
Culture Documents
PROCESS
DIAGRAMS
75% Conversion of
Toluene
PFD
Heat exchanger
S Steam heater
Cooling coil
PROCESS FLOW DIAGRAM (PFD)
Process Unit Symbology
Symbol Description
Heater coil
Centrifugal pump
Pressure gauge
PROCESS FLOW DIAGRAM (PFD)
Process Unit Symbology
Symbol Name
Gate Valve
Globe Valve
Ball Valve
Check Valve
Butterfly Valve
PROCESS FLOW DIAGRAM (PFD)
Valve Symbology
Symbol Name
Relief Valve
Needle Valve
3-Way Valve
Angle Valve
Butterfly Valve
EXAMPLE
Ethanol is feed to continuous reactor with presence of Acid Sulphuric catalyzer to produce
ethylene. Distillation process then will be applied to separate ethylene-H2O mixture.
Ethylene as a top product is then condensate with condenser to perform liquid ethylene.
Hydrogenation of ethylene applies in another reactor with presence of Nickel catalyzer to
produce ethane as a final product. Develop PFD for these processes.
Ethylene
E-100 Ethylene
V-104 liq.
Cold water in
V-106
CV-100 T-100
CV-101
Ethanol V-105
Hot water
out Hot water
out
Ethylene
Ethylene
Ethylene liq.
Cold
water in Cold Ethylene liq.
Ethanol water in
Ethanol
H2SO4 Hydrogen Ethane H2SO4 Hydrogen Ethane
Ni
Ni
H2O H2O
P-100 B
In Real Plant
In PFD
PROCESS FLOW DIAGRAM (PFD)
Yes No No
PROCESS FLOW DIAGRAM (PFD)
Stream Information
-Since diagrams are small not much stream information
can be included.
-Include important data – around reactors and towers, etc.
❑ Flags are used
❑ Full stream data
PROCESS FLOW DIAGRAM (PFD)
Stream Information - Flag
600 Temperature
300
3 8 24 Pressure
9
6 7 Mass Flowrate
10.3
1 10
108 Molar Flowrate
600
24
2 5 12 Gas Flowrate
4 11 Liquid
Flowrate
24
13
R-100 P-100 T-100 E-100 P-101 R-101
Reactor Pump Distillation Column Condenser Pump Reactor
Hot water
out
6
V-104
Cold
T-100
water in CV-101 V-106
25 CV-100
28 V-105
Ethanol 5
1 V-101 V-102 38 20
H2SO4 4 Hydrogen
V-100
V-103 Ni
9
V-107
R-100
R-101 Ethane
3 8
2 35 10
31.0 H2O
35 7 P-101
32.2
P-100
PROCESS FLOW DIAGRAM (PFD)
Vapor fraction
Mass flow 10.3 13.3 0.82 20.5 6.41 20.5 0.36 9.2 20.9 11.6
(tonne/hr)
Mole flow 108 114.2 301.0 1204.0 758.8 1204.4 42.6 1100.8 142.2 244.0
(kmol/hr)
R-100 P-100 T-100 E-100 P-101 R-101
Reactor Pump Distillation Column Condenser Pump Reactor
Hot water
out
Cold
water in V-106
25 CV-100
T-100
CV-101
28 V-105
Ethanol 5 20
H2SO4 1 V-101 V-102
4 38 Hydrogen
V-100
V-103 V-107 Ni
9
R-100
Ethane
3 8
R-101
2 35 10
35 31.0 7 H2O
P-101
32.2
P-100
Stream Number 1 2 3 4 5 6 7 8 9 10
Temperature (oC) 25.0 35.0 35.0 35.0 35.0 60.3 41 38 54 45.1
Pressure (psi) 28 32.2 31.0 31.0 30.2 45.1 31.3 24.0 39 2.6
Vapor fraction
Mass flow (tonne/hr) 10.3 13.3 0.82 20.5 6.41 20.5 0.36 9.2 20.9 11.6
Mole flow (kmol/hr) 108 114.2 301.0 1204.0 758.8 1204.4 42.6 1100.8 142.2 244.0
PROCESS FLOW DIAGRAM (PFD)
CHECK VALVE
Ethylene E-100 Ethylene liq.
PNEUMATIC DIAPHRAGM
6 VALVE
V-104
Cold water in
LIC V-106
25 T-100
CV-100 CV-101
28
V-105
Ethanol 5 20
1 V-101 V-102
H2SO4 4 38 Hydrogen
V-100 9
V-103 V-107 Ni
R-100
3 R-101 Ethane
2 8 10
35
35 31.0 7 H2O
32.2 P-101 LIC
P-100
fs
FLYSIS CHEMICAL
(M) SDN. BHD
Stream Number 1 2 3 4 5 6 7 8 9 10
PROCESS FLOW
Temperature (oC) 25.0 35.0 35.0 35.0 35.0 60.3 41 38 54 45.1 DIAGRAM
Pressure (psi) 28 32.2 31.0 31.0 30.2 45.1 31.3 24.0 39 2.6
PRODUCTION OF
Vapor fraction ETHANE FROM ISSUED :
ETHANOL
Mass flow (tonne/hr) 10.3 13.3 0.82 20.5 6.41 20.5 0.36 9.2 20.9 11.6 DRAWN BY :
PAGE : 1 OF 1
Mole flow (kmol/hr) 108 114.2 301.0 1204.0 758.8 1204.4 42.6 1100.8 142.2 244.0
APPROVED BY :
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
PFD
PIPING AND INSTRUMENTATION DIAGRAM (P&ID)
P&ID
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Basic Loop
Process
Sensing Element
Transmit
Element
Control Element
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Basic Loop
Set point
Controller
Transmitter
Fluid Fluid
Orifice (Flow
Sensor)
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
SENSORS (Sensing Element)
✓ A device, usually electronic, which detects a variable quantity and measures and
converts the measurement into a signal to be recorded elsewhere.
✓ A sensor is a device that measures a physical quantity and converts it into a signal
which can be read by an observer or by an instrument.
TRANSMITTER
Transmitter is a transducer* that responds to a measurement variable and
converts that input into a standardized transmission signal.
*Transducer is a device that receives output signal from sensors.
The operational conditions are typically referred to as output variables of the system
which can be affected by adjusting certain input variables.
Recording Controller
Indicating Controller
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Instrumentation Symbology
Field
mounted on
pipeline
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Instrumentation Symbology
Instruments that are board mounted
-Instruments that are mounted on control board.
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Instrumentation Symbology
Instruments that are board mounted (invisible).
-Instruments that are mounted behind a control panel board.
PIPING AND INSTRUMENTATION
DIAGRAM (P&ID)
Instrumentation Symbology
Principal of P&ID
Example 1
With using these following symbols;
LC LC
LV 100
V-100
LT
LCV 101
The Piping & Instrumentation Diagram (P&ID)
PIPINGSometimes
AND also INSTRUMENTATION DIAGRAM (P&ID)
known as Process & Instrumentation Diagram
Example 2
PRV-100
PE Where PE is locally mounted
on V-100
PE
PIC Where PT is locally mounted
PT
V-100
PT
PIC Where PIC is function in DCS