You are on page 1of 1

7.

44
NOTES FOR CCTV SYSTEM: REPUBLIC OF PHILIPPINES
0.74 6.70
5.60
DPWH
1.18 OFFICE OF THE BUILDING OFFICIAL
1.00 2.25 2.35 1. CONTRACTOR/SUPPLIER TO ENSURE THAT THE CCTV COMPONENTS ARE DULY ENGINEERED WITH
OTHER COMPONENTS IN ORDER TO PERFORM AS REQUIRED & RELIABLE FOR THE INTENDED
SINK
SECURITY SYSTEM OF THE BUILDING. ILOILO CITY
0.67

SLOP
0.78

2. CCTV STORAGE SHALL BE CAPABLE OF RECORDING FOR 30 DAYS & RECORDER SHALL BE DESIGNED
1.34

CCTV TO DVR
TO HANDLE THE CCTV CAMERAS QUANTITY.
0.50

DETECTOR TAPPING
SMOKE DETECTOR
POINT
ELECTRIC
STOVE

RG59 SIAMESE COAXIAL


FREEZER

CABLE
CHEST
BENCH

2.01
3.40

2 MP HD CCTV CAMERAS
T-2

2 BURNER
2.90

REF

HD TO OTHER DETECTORS
6.10

REF

LEGEND:
T-2

SD SMOKE DETECTOR
EL

6.33
EL

BENCH

SD MONITOR
VGA
DVR HD HEAT DETECTOR
3.00

STORAGE DEVICE
LAN PORT
POWER SUPPLY
FIRE ALARM
F
EMERGENCY LIGHT
2.60

MANUAL CALL
T-2

T-1 T-1 POINT


CCTV SECURITY AND SURVEILLANCE EL EMERGENCY LIGHT
GLASS
BREAD SYSTEM RISER DIAGRAM
DISPLAY DIGITAL VIDEO
DVR
PROOFING

0.67
RACK

RECORDER
POINT OF SALE
BENCH

CCTV CAMERA
0.60
T-2

B
15.77

CCTV TO DVR FIRE ALARM BELL


15.69

EL CAT5e
CASHIER
T-1 T-1 UTP Cable
POS
VOICE & DATA
1.34

OUTLET
CHILLER

POINT OF
CAKE DISPLAY 1 VOICE POS SALE
1 DATA
OUTLET
YELLOW
BOX
4.84
EL

COIN SERVER
ISP
2.60
POS
CASHIER

YELLOW BOX
T-1 T-1
VOICE DATA SINGLE LINE DIAGRAM
7.90

VOICE DATA
SD DVR
0.90
CASHIER

8.00
GENERAL NOTES:
CCTV CAMERA
GLASS BREAD

0.90
DISPLAY
FINISH FLOOR LINE 1. ALL ELECTRONICS WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND
SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST BUILDING CODE OF THE PHILIPPINES,

0.46
TO OTHER DETECTORS TO OTHER DETECTORS
THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY , SHALL ALSO COMPLY WITH
THE REQUIREMENTS REVISED FIRE CODE OF THE PHILIPPINES.
2. ALL MATERIALS TO BE USED SHALL BE NEW AND OF THE APPROVED TYPE BOTH LOCATION AND

3 TIER GONDOLA
FLEXIBLE METAL
CONDUIT
PURPOSE INTENDED.

2.10
3. THE POSITION OF ALL DEVICE/EQUIPMENT AS SHOWN IN THE DRAWING ARE APPROXIMATE ONLY. THE

3.16
CCTV TO DVR
PLYWOOD SUPPORT
EXACT LOCATION SHALL BE DETERMINED ON THE SITE.
PACK PRODUCTS
OCTAGONAL BOX
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LABELING OF ALL EQUIPMENT THROUGHOUT
3 TIER GONDOLA
THE INSTALLATION.
1.02

5. MOUNTING FOR FDAS DEVICES SHALL BE FOLLOW:

0.60
a. DETECTORS
3.03 1.29 1.60 0.50 LOCKING SCREW
DETECTOR HEAD HEIGHT : CEILING HEIGHT OR AS REQUIRED
6.42
SHOULD NOT BE MOUNTED WITHIN 500mm OBSTRUCTION
1.02 6.42 DETECTOR DETAIL ON DROP CEILING W/ CONDUIT EXPOSED
b. BELL
7.64 HEIGHT : 2m AFFL
c. FIRE ALARM MANUAL CALL POINT/PULL STATION
PROPOSED PRINCE BAKER FLOOR PLAN HEIGHT : 1.10m to 1.4m AFFL
SCALE : 1 : 100 MTS. 6. LOCATION OF PULL/CALL POINTS BE NEAR EXITS/ FIRE EXITS.
FLOOR SLAB
7. ALL FIRE DETECTION AND ALARM ARE CONNECTED TO A CENTRAL POWER SUPPLY.
8. ALL EQUIPMENT CONFIGURATION/WIRING ARE SUBJECT TO MODEL SPECIFICATIONS.
9. END OF LINE RESISTOR/DEVICES RATING SHALL BE SUBJECT TO FACP MODEL SPECIFICATIONS.
SD
TO OTHER DETECTORS
SD HD 10. UNLESS OTHERWISE SPECIFIED, MINIMUM WIRE SIZE SHALL BE IN 18 AWG.
TO OTHER DETECTORS
TO OTHER DETECTORS
DETECTOR BASE
11. CABLES/WIRINGS SHALL BE CONCEALED IN CONDUITS.
12. EXPOSED CONDUIT SHALL BE MADE OF METAL, PVC CONDUITS SHALL BE EMBEDDED IN CONCRETE.
TO MALL'S
FACP
OCTAGONAL BOX
13. ALL WORKS SHALL BE DONE UNDER DIRECT SUPERVISION OF A DULY LICENSED PROFESSIONAL
DETECTOR HEAD
ELECTRONICS ENGINEER.
14. NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT THE PRIOR AND APPROVAL OF THE
SURFACE MOUNT DETECTOR DETAIL
FIRE DETECTION AND ALARM SYSTEM SINGLE LINE DIAGRAM ARCHITECT OR PROFESSIONAL ELECTRONICS ENGINEER.
PROJECT TITLE : OWNER : Drawings and Specifications duly signed, stamped or sealed as SHEET CONTENT : SHEET NO:
instruments of service, are the intellectual property and
documents of the Architect, whether the subject for which they - ELECTRONICS LAYOUT PLAN
DYJEE A. GALLEGA PROPOSED PRINCE BAKER are made is executed or not. It shall be unlawful for any person to
make copies of the said documents in repetition of and for other
- FIRE DETECTION AND ALARM SYSTEM
SINGLE LINE DIAGRAM ECE -1
(SM CITY ILOILO) projects or buildings whether
executed in part or in whole without the written consent of the
- CCTV SECURITY AND SURVEILLANCE
SYSTEM RISER DIAGRAM 1
PTR No. : 7607748
TIN : 927-392-721
PRC No. : 0000366
PLACE & DATE ISSUED : ILOILO CITY 1-8-2022
LOCATION : SM CITY ILOILO, BENIGNO AQUINO AVE., MANDURRIAO ILOILO CITY SARI SARI BREAD NETWORK INC. CORP. Architect or author of the said documents. (reaffirms the
pertinent provisions of R.A. 8293 Intellectual Property Code)

You might also like