Professional Documents
Culture Documents
SP-Appendix2 Error Message
SP-Appendix2 Error Message
2005
Contents
1 Error Message 3
SP Series
Appendix2: Error Message
LONG! Buffer.
THE AIRFLOW SENSOR 1. Check which malfunctions,
E069 OF RESISTOR RACK Fan or sensor malfunctions.
2. Call BAC services enter.
ERROR!
E070 A TRANSISTOR OF False trouble with high frequency, or Lengthen “pulse duration (PW)” or
transistor on BMP-50 board
BMP-50 FAILURE! malfunctions. change BMP-50 board.
THE AIRFLOW SENSOR 1. check which malfunctions,
E071 OF RESISTOR RACK Fan or sensor malfunctions.
2. call BAC services enter.
ERROR!
E078 TEMPERATURE INSIDE Temperature inside cabinet exceeds 1. check fans inside cabinet,
CABINET IS TOO HIGH! o 2. replace filter at air inlet and outlet.
51 C.
E079 THE DOOR OF TANK IS
OPEN!
E080 FUME EXTRACTOR
DOES NOT WORK!
Disk is not ready! While reading and writing disk, in the Insert a disk.
drive no floppy disk.
There is no NC file in disk! When loading NC program, no NC Insert a disk with NC program
program in disk.
Disk is write protected! While reading or writing a disk, the disk Open write protection,
is in write protection state.
CAN NOT OPEN THE When reading or writing a disk, file can 1. change disk,
FILE! not be opened. 2. change disk drive.