You are on page 1of 8

Date:18.10.

2021

BAYSU Water Treatment Systems is our Aquabay Registered Brand ®

Customer Name: PICKALBATROS AGADIR


Offer Capacity: 10 m3/hour

Official Distributor :
Offer No: NT2E_WT_211012
Revision No:00
RAW WATER SYSTEM DESIGN PARAMETERS

Raw Water Source: Well Water

UNIT RAW WATER


Colour Pt-Co Clear
Odor Absent
Turbidity NTU <1
Temperature 0C 25
TDS mg/L ≤17.500
SDI <3
COD mg/L <3
BOD mg/L <2
Calcium mg/L ≤120
Magnesium mg/L ≤70
Potassium mg/L ≤3
Sodium mg/L ≤6000
Sulfate mg/L ≤2930
Nitrate mg/L ≤63
Ammonium mg/L Absent
Chloride mg/L ≤7778
Bicarbonete mg/L ≤380
Iron mg/L Absent
Manganese mg/L Absent
Arsenic mg/L Absent
Silica mg/L ≤30
Boron mg/L Absent
Barium mg/L Absent
Strontium mg/L Absent
Flooride mg/L Absent
Aluminum mg/L Absent
Free Chlorine mg/L Absent
Organic Matter mg/L Absent
Oil, Grease mg/L Absent
Hydrogen Sulfide mg/L Absent
pH - 7,90
Total Coliform ctu/mL Absent
E. Coli ctu/mL Absent

* The RO system was designed according to the raw water parameters given above. If the raw water criteria
change at any time, the efficiency of the system and the product water quality may change accordingly. In
case of change of conditions, technical and commercial revision of our offer is required.
PROCESS PERMEATE WATER VALUES

Reverse Osmosis System %50


pH 4,76 ± 0,2
Conductivity (μS/cm) < 500
Product Water Flowrate ( /hour) 10

TECHNICAL PROPOSAL

AQUABAY BMF-42-MULTI MEDIA SAND FILTER UNIT


Quantity 1 pc.
Flowrate 20 m3/hour
Filtration Area 0,89 m2
Filtration Velocity 16 m/hour
Valve Control Logic Electricaly Actutated
Valve Quantity 5 pcs. / Tank
Otomation Siemens Logo
Tank Dimensions D: 1080 mm H Total:2400 mm
Tank Material FRP
Face Piping Material PVC
Mineral Quantity 775 kg Quartz + 210 lt Antrasit
Inlet-Outlet 2 ½”
Back 26,7 m3/hour
Test Pressure 9 Bar
Operating Pressure 2-6 Bar
Face Piping Skid ST-37 Epoxy Coated Stainless Steel

ACID DOSAGE SYSTEM


Chemical which will be dosed HCl (%31)
Dosing Pump Quantity 1 Unit
Dosing Pump Brand Antech
Dosing Pump Capacity 5 L/hr – 10 bar
Control pH Control
Chemicak Tank Quantity 1 Unit
Chemical Tank Volume 100 L
Chemical Tank Material Polyethylene
Bottom Level Electrode 1 Unit
ASC DOSAGE SYSTEM
Chemical Name ASC (%100 Liquid Form)
Dosing Pump Quantity 1 Unit
Dosing Pump Brand Antech
Control On/Off
Dosing Pump Capacity 8 liter/Hour
Operating Pressure 2 bar
Chemical Tank Quantity 1 pc.
Chemical Tank Matter Polyethylene
Bottom Level Electrode 1 Unit

AQUABAY ASRO-10 REVERSE OSMOSIS SYSTEM


System Design
Feed Water Flow 20 m3/hour
Product Water Flow 10 m3/hour
Recovery %50

Cartridge Filter
Quantity 1 Set
Dimension Multi Cartridge
Cartridge Quantity 5 Units
Dimension 40”
Filtration Degree 5 Micron
Brand **
Material PVC

High Pressure Pump


Quantity 1 pcs
Brand GRUNDFOS or Equivalent
Capacity 20 m3/hour @ 30 bar
Material SS316 L

Membrane
Quantity 12 pcs
Dimension 8”
Brand LG or FILMTEC

Membrane Vessel
Quantitiy 3 pcs
Dimension 8” Diameter 4 element
Brand Aquabay
Analyzers
Conductivity Control
Quantitiy 1 pcs
Using Place At the Product Water Line
Type Digital Screen Fixed on the Control Panel
Brand ***

Flow Control
Quantity 2 Units
Using Place At the Product Water and Drain Water Line
Type Inline
Brand LZS

Pressure Control
Quantity 2 Units
Using Place At the Inlet and Outlet of High Pressure Pump
Type Pressure Switch
Brand Danfoss

Manometer
Quantity 1 Set
Measuring Range 0-10 / 0-20 bar
Brand **

Valves
Automactic Valves
Quantity 2 Units
Using Place At the Raw Water and Autoflash Line
Type Electrically Actuated Valve

Flow Adjustment Valves


Quantity 2 Units
Using Place At the Raw Water and Drain Water Line
Type Gate Valve

Piping
Material At the High Pressure Line DUBLEX
At the Low Pressure Line PVC-U

Skid
Material ST-37 Epoxy Coated Carbon Steel

Control Panel PLC


AUTOMATIC RINSING & CIP SYSTEM

Washing Pump
Capacity 10 m3/hour @ 3 bar
Brand Ebitt or Equivalent
Material AISI 316 Stainless Steel

Washing Tank
Capacity 200 L
Material PE

Piping
Material PVC

Valves
Automatic Valves
Quantity 2 Units
Type Electrically Actuated Valve

Manuel Valves
Quantity 5 Units
Types Ball / Butterfly Valve
• SCOPE OF CUSTOMER

1. Civil works and infrastructure work


2. Supplying the energy required for the operation of the system and delivering it to the BAYSU
panels
3. Unloading the system equipment from the vehicle, horizontal-vertical transport operations
4. Supply of instrument compressed air required by the system (min. 6 bar conditioned).
5. Drainage system, indoor and outdoor air conditioning, lighting, sound insulation in the facility
building,
6. Supply of raw water, drawing the raw water line up to the raw water inlets of the devices
specified in our offer,
7. Body and panel grounding on the devices, making an independent grounding system for
instrument grounding in accordance with the standards.
8. Supply of chemicals and consumables and filling the related tanks.
9. Regarding permits, civil works and designs that may be required; building inspection, license
fees and expenses, professional chamber approval fees and all kinds of permits
10. All waste disposal processes
11. All other work not specified in this offer but may be required for the process.
• GENERAL WARRANTY CONDITIONS
1. BAYSU Water Treatment Systems are guaranteed against material and manufacturing defects
for 2 years from the invoice date.

2. Within the warranty period; The repair of the material/equipment that fails due to material,
manufacturing faults is/is done by BAYSU free of charge. The time spent in repair is added to the
warranty period of the relevant material/equipment.

3. The warranty period of the replaced material/equipment within the warranty period is limited
to the remaining warranty period of the replaced material/equipment.

4. Warranty for system membranes and consumables is implemented as Pro-Rata.


5. Annual performance degradation of 5-10% may be observed for system membranes and
consumables that wear out as they work.

6. A performance change of 5% is observed for system ion exchangers.

7. System equipment is out of warranty in matters arising from fluctuations in the energy feeding
the system or out-of-standards.

8. The systems are not covered by the warranty as a result of the intervention of third parties or
the uninformed intervention of the customer during the relevant warranty period.

9. Damage or performance changes caused by ignoring the warnings and notes in the operating
and maintenance manuals are not covered by the warranty.

10. Design changes resulting from changes in raw water analysis values based on process design
are not covered by the warranty.

11. Upon notification of the malfunctions occurring in the process in written form (e-mail, fax,
etc.), we will start to intervene in the system. Verbal notifications do not have a valid provision.

You might also like