RAW WATER SYSTEM DESIGN PARAMETERS
* The RO system was designed according to the raw water parameters given above. If the raw water criteria
change at any time, the efficiency of the system and the product water quality may change accordingly. In
case of change of conditions, technical and commercial revision of our offer is required.
PROCESS PERMEATE WATER VALUES
TECHNICAL PROPOSAL
Cartridge Filter
Quantity 1 Set
Dimension Multi Cartridge
Cartridge Quantity 5 Units
Dimension 40”
Filtration Degree 5 Micron
Brand **
Material PVC
Membrane
Quantity 12 pcs
Dimension 8”
Brand LG or FILMTEC
Membrane Vessel
Quantitiy 3 pcs
Dimension 8” Diameter 4 element
Brand Aquabay
Analyzers
Conductivity Control
Quantitiy 1 pcs
Using Place At the Product Water Line
Type Digital Screen Fixed on the Control Panel
Brand ***
Flow Control
Quantity 2 Units
Using Place At the Product Water and Drain Water Line
Type Inline
Brand LZS
Pressure Control
Quantity 2 Units
Using Place At the Inlet and Outlet of High Pressure Pump
Type Pressure Switch
Brand Danfoss
Manometer
Quantity 1 Set
Measuring Range 0-10 / 0-20 bar
Brand **
Valves
Automactic Valves
Quantity 2 Units
Using Place At the Raw Water and Autoflash Line
Type Electrically Actuated Valve
Piping
Material At the High Pressure Line DUBLEX
At the Low Pressure Line PVC-U
Skid
Material ST-37 Epoxy Coated Carbon Steel
Washing Pump
Capacity 10 m3/hour @ 3 bar
Brand Ebitt or Equivalent
Material AISI 316 Stainless Steel
Washing Tank
Capacity 200 L
Material PE
Piping
Material PVC
Valves
Automatic Valves
Quantity 2 Units
Type Electrically Actuated Valve
Manuel Valves
Quantity 5 Units
Types Ball / Butterfly Valve
• SCOPE OF CUSTOMER
2. Within the warranty period; The repair of the material/equipment that fails due to material,
manufacturing faults is/is done by BAYSU free of charge. The time spent in repair is added to the
warranty period of the relevant material/equipment.
3. The warranty period of the replaced material/equipment within the warranty period is limited
to the remaining warranty period of the replaced material/equipment.
7. System equipment is out of warranty in matters arising from fluctuations in the energy feeding
the system or out-of-standards.
8. The systems are not covered by the warranty as a result of the intervention of third parties or
the uninformed intervention of the customer during the relevant warranty period.
9. Damage or performance changes caused by ignoring the warnings and notes in the operating
and maintenance manuals are not covered by the warranty.
10. Design changes resulting from changes in raw water analysis values based on process design
are not covered by the warranty.
11. Upon notification of the malfunctions occurring in the process in written form (e-mail, fax,
etc.), we will start to intervene in the system. Verbal notifications do not have a valid provision.