You are on page 1of 8

CALCULATION SHEET

Name RBC-DR4 (RD 4+626)


Component
Feature Design Of Submerged Pipe Outlet

INPUT DATA

Channel Data Water Course Data

Q= 0.210 m3/Sec q= 0.050 m3/Sec


FSL = 1254.96 m FSL = 1254.83 m
BL = 1254.20 m h= 0.13 m
D= 0.76 m Cd = 0.80
B= 0.75 m g= 9.81 m2/Sec

q = Cd * a 2gh

Area Of Pipe = a = 0.04 m2

a = 3.143 * r²

a = 3.143 * d²/4

Dia Of Pipe = Ø = 0.223 m


223 mm

h =0.13m

D = 0.76m
Pipe Outlet
B = 0.75m
EXTENSION OF PAT FEEDER CANAL PROJECT
NATIONAL DEVELOPMENT CONSULTANTS
In Association with: Engineering Consultants Int. Ltd. (ECIL)

CALCULATION SHEET
Name Qabula Disty
Component Command Area Development
Feature Open Flume Outlet

FSL HW

D-G
q = K * Bt * G^1.5 Bt
G = 0.9 * D 0.06 to0.09m
HM = 0.2 * G 0.09 to 0.12m
H / D = 0.9 Over 0.12m
H = 0.9 * D

OPEN FLUME OUTLET

RD Location of outlet q q HW D B G=H K Bt HM


Sr. No.
(m) R /L /T f3/Sec m3/Sec (m) (m) (m) (m) (m) (m) (m)
1 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.60 #REF! #REF!
2 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.60 #REF! #REF!
3 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.60 #REF! #REF!
4 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
5 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
6 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
7 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
8 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
9 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
10 #REF! #REF! #REF! #REF! #REF! #REF! #REF! #REF! 1.66 #REF! #REF!
EXTENSION OF PAT FEEDER CANAL PROJECT
NATIONAL DEVELOPMENT CONSULTANTS
In Association with: Engineering Consultants Int. Ltd. (ECIL)

CALCULATION SHEET
Name Qabula Disty
Component Command Area Development
Feature Submerged Pipe Outlet

D 1.5:1
Pipe Outlet
B

q = Cd * a 2gh
a = 3.143 * d²/4
PIPE OUTLET Cd = 0.80 For Submerged Outlet
Cd = 0.63 For Free Fall Outlet
RD Location of outlet q q Disty BL Disty FSL HW D B Ø a
Sr. No.
(m) R /L /T f /sec
3
m /sec
3
(m) (m) (m) (m) (m) mm m2
1 0+151 Outlet (L) 0.71 0.02 1300.95 1301.85 0.05 0.90 1.00 175 0.02 138.167
2 1+004 Outlet (L) 0.35 0.01 1284.30 1285.18 0.14 0.88 1.00 101 0.01 94.386
3 1+723 Outlet (L) 0.35 0.01 1284.18 1285.04 0.14 0.85 1.00 101 0.01 94.386
4 3+371 Outlet (L) 1.06 0.03 1268.43 1269.21 0.13 0.78 1.00 175 0.02 167.328
5 3+926 Outlet (L) 1.41 0.04 1261.15 1262.10 0.14 0.95 0.75 199 0.03 192.113
6 4+626 Outlet (L) 1.77 0.05 1254.20 1254.96 0.13 0.76 0.75 226 0.04 214.047
7 5+500 Outlet (L) 1.41 0.04 1250.07 1250.78 0.14 0.71 0.65 199 0.03 192.113
8 6+155 Outlet (L) 1.06 0.03 1240.59 1241.15 0.13 0.56 0.65 175 0.02 167.328
No : Rev :
1 of 2

By : Date :
M. Yasar 07-10-2006

Checked By: Date :


Haroon 07-10-2006

k
1.60
1.64
1.66
No : Rev :
1 of 2

By : Date :
M. Yasar 07-10-2006

Checked By: Date :


Haroon 07-10-2006
PIPE OUTLET

DISTY BED INVERT DISTY FULL NSL AT OUTLET OUTLET WORKING FLOW
ROAD LEVEL BANK LEVEL FREE BOARD
LEVEL LEVEL SUPPLY LEVEL OUTLET HEAD DISCHARGE DISCHARGE HEAD DEPTH

EI.B EI.D EI.C EI.A EI.E R. Bank Lvel F.B q q HW D


(m) (m) (m) (m) (m) (m) (m) (f /sec)
3
(m /sec)
3
(m) (m)
1300.95 1301.13 1301.85 1304.00 1302.15 1302.25 0.40 0.71 0.020 0.05 0.90
1284.30 1284.48 1285.18 1286.50 1285.48 1285.58 0.40 0.35 0.010 0.14 0.88
1284.18 1284.35 1285.04 1285.00 1285.34 1285.44 0.40 0.35 0.010 0.14 0.85
1268.43 1268.58 1269.21 1273.00 1269.51 1269.61 0.40 1.06 0.030 0.13 0.78
1261.15 1261.34 1262.10 1262.50 1262.40 1262.50 0.40 1.41 0.040 0.14 0.95
1254.20 1254.35 1254.96 1257.50 1255.26 1255.36 0.40 1.77 0.050 0.13 0.76
1250.07 1250.21 1250.78 1250.50 1251.08 1251.18 0.40 1.41 0.040 0.14 0.71
1240.59 1240.70 1241.15 1242.00 1241.45 1241.55 0.40 1.06 0.030 0.13 0.56
BED DIA OF
AREA
WIDTH PIPE

B Ø a
(m) (m) m2
1.00 0.17 0.024 7
1.00 0.10 0.008 4
1.00 0.10 0.008 4
1.00 0.17 0.024 7
0.75 0.20 0.031 8
0.75 0.23 0.040 9
0.65 0.20 0.031 8
0.65 0.17 0.024 7
PIPE OUTLET(EPFCP-10)

BED LEVEL INVERT LEVEL FSL NSL ROAD LEVEL R. Bank Lvel DIA OF PIPE AREA DIA OF PIPE
RD LOCATION
EI.B EI.D EI.C EI.A EI.E Ø a d
(m) R /L /T (m) (m) (m) (m) (m) (m) (m) m2 (m)
0+151 Outlet (L) 1300.95 1301.13 1301.85 1304.00 1302.15 1302.25 0.175 0.024 0.533
1+004 Outlet (L) 1284.30 1284.48 1285.18 1286.50 1285.48 1285.58 0.101 0.008 0.533