MOSTAKBAL CITY

Bill Of Quantities
For Landscape Works
ELECTRICAL WORKS FOR LIGHTING

Landscape Consultant
Amount
Type Item Description Unit Qty.
CABLES LE

Electrical Works Page 2 of 3


700496982.xlsx
Amount
Type Item Description Unit Qty.
CABLES LE
2 Lighting Outlets:

Supply , install and test lighting outlet using copper


thermoplastic cable (3x4)mm² inside PVC conduits with
diameter 20 mm for embedded installation in ground from
panel till junction box & between junction boxes. And with
copper thermoplastic cable (3x1.5) mm² inside PVC
2.1
conduits with diameter 20 mm for embedded installation in No. 1,400 14,000
ground from junction box to lighting fixture ; the price
includes thermoplastic cables,conduits , excavation ,
backfilling and all required accessories , fittings and
material to complete the work according to specifications
and drawings. (with average length 10m for outlet)
Material to be approved from consultant/owner

Supply , install and test lighting outlet using copper


thermoplastic cable (3x6)mm² inside PVC conduits with
diameter 25 mm for embedded installation in ground from
panel till junction box & between junction boxes. And with
copper thermoplastic cable (3x1.5) mm² inside PVC
2.2
conduits with diameter 20 mm for embedded installation in No. 44 440
ground from junction box to lighting fixture ; the price
includes thermoplastic cables,conduits , excavation ,
backfilling and all required accessories , fittings and
material to complete the work according to specifications
and drawings. (with average length 10m for outlet)
Material to be approved from consultant/owner

Supply , install and test lighting outlet using copper


thermoplastic cable (3x16)mm² inside PVC conduits with
diameter 40 mm for embedded installation in ground from panel
till junction box & between junction boxes. And with copper
thermoplastic cable (3x1.5) mm² inside PVC conduits with
diameter 20 mm for embedded installation in ground from
junction box to lighting fixture ; the price includes thermoplastic
cables,conduits , excavation , backfilling and all required
2.3 accessories , fittings and material to complete the work according No. 100 1,000
to specifications and drawings. (with average length 10m for
outlet)
Material to be approved from consultant/owner

Electrical Works Page 3 of 3


700496982.xlsx