K Fan Vent Kit
K Fan Vent Kit
January, 1994
PARTS LIST
Item Quantity Description
8 Foot 12 Foot
1. 1 1 Fan Ventilation Assembly
2. 2 3 Fan Vent Covers
3. 14 18 8 x 1/2 Sheet Metal Screws
Whenever the condition of a store’s ambient air is above the design standard of these merchandisers
(75°F; 55% relative humidity) a problem of moisture condensing on the merchandiser’s exterior back
surfaces can occur. To eliminate this problem, air must be forced through the open area behind the
merchandiser to “wipe” the surface dry. This kit is designed for that purpose.
This kit is completely factory assembled and ready for installation. All that is required is to fasten it to the
top of the merchandiser, connect to an electrical power supply and close-off the open areas at the end of the
merchandiser or merchandiser lineup.
P/N 112489K 2
NOTES:
Be sure Merchandisers have been leveled
according to the installation instructions 1
under Leveling.
Before installing this kit, make certain that
there is A MINIMUM 4 INCH CLEARANCE
between the back of the merchandiser and 4 Inch
(102 mm)
the wall. Gap
If merchandisers have been installed back-
to-back in a line-up, make certain that there
is A 4 INCH CLEARANCE between the
merchandisers.
Figure 1B
Merchandisers Back-to-Back
3 P/N 112489K
STEP 2. Remove
Fan Vent Covers – 2 2
3
Electrical Box
Serial Plate 3
4 in.
(102 mm)
Figure 2
Removing Vent Covers
STEP 3. Fasten the assembly to the
top of the merchandiser
through the bottom flange of
the end caps using
Sheet Metal Screws – 3
End Cap
End Cap
4 in.
(102 mm)
4 in.
3 (102 mm)
3
Figure 3A Figure 3B
Merchandiser Against the Wall Merchandisers Back-to-Back
P/N 112489K 4
Close
Off
Figure 5A Figure 5B
M erchandiser Against the Wall M erchandisers Back-to-Back
5 P/N 112489K