Yakma Yöneti̇m Si̇stemleri̇ Combustion Management Systems
Yakma Yöneti̇m Si̇stemleri̇ Combustion Management Systems
Kazan/Brülör MM Kontrol
Boiler / Burner Modülü
MM Control
DTI Bilgi Aktarım Module
Ünitesi
DTI Data Transfer
Interface
www.selnikel.com
Mk7 MM
KONTROL MODÜLÜ
Mk7 MM Control Module
Dokunmatik Ekran
Touchscreen
Mk7 MM
Mini Mk8 MM
Dokunmatik Ekran
Touchscreen
MM Modülleri üzerinden seçilen çeşitli ekranlar sayesinde bir çok fonksiyon anlık olarak izlenebilir.
Many functions of MM can be monitored by selecting various screens on MM modules.
Harici Yük
Sensörü veya / or Frekans Kontrol Cihazı
External Load Duman Variable Speed Drive
Sensor Flue Gas
Baca Gazı
Aspiratörü Ch6
Gaz / Gas Draught Fan
• Ventil Sızdırmazlık Kontrolü Ega Prob
Gaz Basınç • Düşük / Yüksek Gaz Basıncı Ega Prob
Sensörü Kontrolü Kapasitans Probları
Gas Press. Sens. • Valve Proving Capacitance Probs
• Low / High Gas Press. Control
Buhar Basınç Buhar Sıcaklık
Sensörü Sensörü Baca Gazı Analiz
Steam Press. Steam Temp. Cihazı (Mk8 EGA)
Yağ Basınç Sensor Sensor Exhaust Gas Analyser
Sensörü (Mk8 EGA)
Oil Press. Sens.
Ch.1
Hava Basınç Yakıt Servo
Sensörü Motoru
Taze Hava Fanı Air Press. Sens. Ch.1 Fuel
Fresh Air Fan Servo Motor
Dip Blöfü
Frekans Bottom Blow
Kontrol Cihazı Down
Variable Speed
Ch5 Drive
Mk7 MM / WLC
Mk8 EGA
MM Kontrol Modülü
MM Control Module
Mk8 EGA
Up to 10 MM’s
Up to 10 EGA’s
Up to 10 I/O’s
The Aim and Function: EGA systems can be viewed using CEMS code, etc.)
The Data Transfer Interface (DTI) software over a local PC or internet. EGA - Exhaust Gas Analyzer Data:
is a gateway for communicating Data Transferred From DTI: (Instantaneous and commissioned
with Autoflame MM/EGA range of MM - Fuel / Air Ratio Data: value of O2, CO2, CO, NO, SO2,
products. The DTI can collect and store NO2, exhaust temperature, combustion
(required and actual pressure/
information from a maximum of 10 efficiencey, EGA error conditions)
temperature value, burner firing rate,
Autoflame Systems (MM,EGA, I/O) in
servo motor positions, burner firing
one location and sends to an external
status, lead boiler and sequence status, Settings via DTI:
sources (PC, PLC, BMS) via RS422 or
error messages, etc.)
Ethernet links. • Pressure/temperature set point
MM - Burner Control Data:
The Mk7 - DTI also supports the Modbus • Lead boiler selection for boiler
protocol over ethernet and RS422 as (actual and commissioned value of gas, sequencing
standart. air and oil pressure, total hours run and • Enable / disable burner
The data gathered by DTI from MM/ number of start-ups, lockout status and