Petrofac 6
Satah Al Razboot (SARB) Field
Development Project —
Package 3 EPC Work
Magnetic Particle Examination
Procedure for Structural
Job No. 10603
Sub Contract /P.O. No.PIL-OCP-DYM-0S00001-002
Construction Engineering, Fabrication, Load out
and Sea Fastening of Structures
Ff |
1 | ans _|—ForRevew and Approval ck | ef
7 Prepared | checked | Aaproved
a est 1 ey By(0K =< MAGNETIC PARTICLE TESTING
ee AR {056072 and PD 6513)
Magnetic Particle Testing
In Accordance with BS 6072 and PD 6513=< m oem [MAGNETIC PARTICLE TESTING
MeeARMe
{BS 6072 and PD 6513)
CONTENTS
Section Description Page No.
= [eoverrace 1
cconrenrs 2
REWION DETALS 3
1 PURPOSE 4
2 SCOPE 4
3 REFERENCES 4
4 | periwmions 4
5 EQUIPMENT & CONSUMABLES / CALIBRATION 4
6 | MATERIAL PRePanation 6
7 __| APPLICRTION OF EXAMINATION MEDIA 7
8 _[ ITenPRETATION AND EVALUATION OF INDICATIONS. 7
9 | AccePrance cnreRia °
‘02 | process pms. vesseis
‘92 | sraucrunes
10 | pocumenrarion 9
x1 oe-wacnerizanon 10
22 __ | posr-examinanon cLEANiNg 10
13 [personne quaricatrion sion Test 10
au [sarc 10
15 | arracumewts—Report Format un= Kone MAGNETIC PARTICLE TESTING
Lv ARM (8S 6072 and PD 6513)
Subsection: Re
jn Matrix
Rev. | isue | Date of
e Prepared Reviewed | Approved
ie neal sine Descriptor ef “ a
Francs TROM | neg
ASNT Level fohames
o | a | axens Original ssue Inecrno.sasra) | Staheer | Bly Harkin
rureraaraer | Noranath
Tivieed toineorporate | FanceThomas |
client's comments. Changes | ASNT Level ham
1] A | 2516/13 | eee spoars20,.0,20, | Mcerno.zs7e) | staveer | ay Hain
13 rurjerarreer | _Seranat
| ____
Pe aang ans
we CEN. cdi COLI
PNp.tox: 4384 abut bi-t!
NB: This isa digitally sled document and hence the printed dacument need not be manualy signed.cm MAGNETIC PARTICLE TESTING
MEGARME)
(Bs 6072 and Po 6513)
10
20
30
40
50
PURPOSE
“This procedure is designed to allow for detection of surface discontinuities within ferrous
materials
score
‘This procedure details technique for Visible Magnetic Particle Inspection (Wet Method Dry
Method), utilising Yoke technique for detecting at or near surface discontinuities within
ferro - magnetic metals on Structures & Welds, inespective of shape and sizes, In
accordance with 85 6072 and PD 6513; and shall demonstrate to the satisfaction of the
Cent's Authorised Inspector.
‘The extent of examination shall be as specified in the cients specifications), specified inthe
applicable document(s).
REFERENCES.
31 FEMUAISS
3.2. Bitsh Standard €s 6072
3.3 british Standard ES 6513 ~
34 ASME SECTION V
3.5 Project Spec ADMA-OPCO-PRO104
3.6 Project Spec AMA-OPCO-SP1031,
3.7 Project Spec ADMA-OPCO:SP 1007
38 WEINP-OL - Witten Practice for Training, Qualification & Certification in Non-
Destructive Testing of Megarme Personnel
DEFINITIONS
As perl referenced documents
EQUIPMENT & CONSUMABLES / CALIBRATION,
5.1 Magnetisation Technique
5.1.1. Yoke TechniqueMAGNETIC PARTICLE TESTING
(8s 6072 and Po 6513)
‘TPE / CURRENT
5.1.1 Magnetisation shall be produced by Electromagnet (AC) or Permanent
‘Magnet. Where possible Flectro-Magnets shall be used,
5.1.1.2 Ut checks (Callration) shall conform to the following and check for
IMagnétisaion capacity dally
POLE SPACINGSTRENGTH / FORCE FREQUENCY
Permanent Max pol spacing
“That wll be used
40 Ubs (28 kg for 2"-4") Daily
SoLbs (22 Kg fora")
ac
52,
53,
54,
6months/whendamaged /
repaired
Electro Yoke Maxpoll spacing
that wll be used
10 Lbs (45 Ke)
Method of magnetisation to be used forall surface areas to be inspected must be
‘established so as to show a satisfactory indication on a magnetic fleld indicator for
‘electromagnets. more than one work piece isto be Inspected, the fist piece only
reeds be checked with the indcator.
Indicating. media shall be stired or agitated periodically to assure adequate
‘concentration of particles. The medium shall be checked for concentration in
accordance with manufacturers’ recommendations, For prepared magnetic inks,
concentration checks may be exempted provided that documented evidence is
provided in the form of a batch test certificate or certificate of conformity from the
‘manufacturer, in ecordance with a recognised National Standard
Indicating medium shall be water solvent suspension or dry powder of black / ved
{erromagnetic particles. Acceptable trade name I~
~Fohnson & Allen
[Consumables ‘Manufacturer ‘Model Number |
Ly ‘wer 172
‘White Contrast paint ‘Magnaflux WP?
NeoPaint wr 16/2
Ly ‘Supramor 4
Dlack Magnetic tne Mognofive | THE
Johnson & Allen Neocol B
Wate: Where posible water based carter fluids shal be wsed.1