HT 4 ABNORMALITIES NEED TO CORRECT WHILE SHUT DOWN

SR NO. ABNORMALITES STATUS RESPONSIBLE


1 WHEELS LOADING CONVEYOR SENSORE MALFUNCTION FREQUENTLY DONE
2 BURNER NO.1 FREQUENTLY MISS FIRE NEED TO ADJUST FLOW. DONE
3 LIFTING UNIT LOADING & UNLOADING SIDE SAFETY BARRICATION NOT PROVIDED. PENDING RAHUL SAIN
4 LOADING LIFTING UNIT CABEL TRAY REMOVE & ALSO ALL CABLE TRAY IN OPEN CONDITION YET COVER NOT FIXED. PENDING SATAYABRAT
5 ZIG ZAG PROBLEM CONTINUE AT SOLUTION EXIT & AGEING EXIT NEED TO REPLACE BEND ROLLERS ,CUP & WORM-PINNION GEAR. WIP DIPAK PATEL
6 FOR REMOVING RE-HT WHEELS NEED TO CUT SIDE GIDE ROD FROM AGEING INPUT CONVEYOR. DONE
7 HEAT LEAKAGE FROM CHAMBER INSULATION NEED TO CORRECT INSULATION. DONE
8 SOLUTION FURNACE MAIN GEAR BOX NEED TO REPLACE WITH ORIGINAL. DONE
9 REQURE ALL NEW THERMOCOUPLE WITH CALIBRATION & ALSO NEED TO CHANGE OLD THERMOCOUPLE WIRE. PENDING SATYABRAT
10 AGEING UNLOADING UNIT UPPER LAYER MOSTLY ALL ROLLER ROTATING OVAL DUE TO CUP SHAFT BEND NEED TO REPLACE WITH NEW ONE. PENDING DIPAK PATEL
11 ALL PANEL AC NOT WORKING. DONE
12 AGEING ZONE 1 BURNER TRIP PER SHIFT./ NEEDS TO CHANGE SPARK PLUG ROD PENDING SATYABRAT
13 JUMBO DESPLAY INSTALLATION(SOLUTION TEMP, AGEING TEMP, QUENCHING TEMP) PENDING SATYABRAT
14 AIR PRESSURE GAUGE NOT INSATLLED. PENDING RAHUL SAIN
15 LADDER REQIRE AT LOADING SIDE & ALSO PERMENANT TABLE REQURE AT AGEING UNLOADING SIDE. DONE
16 MIRROR REQUIRED FOR AGING OUT AREA. PENDING RAHUL SAIN
17 ALLSENSORS TIGHTENING REQUIRED. DONE
18 NEED TO PROVIDE ENTRY DOOR AT SOLUTION LOADING SIDE. PENDING RAHUL SAIN