This document discusses various topics related to boiler operation and safety including cold starting procedures, safeties, flame failure protection, water testing, safety valve operation, gauge glass checks, blowdown procedures, circulating pumps, differences between auxiliary and main boilers, drum levels, temperatures, water levels and their consequences, boiler mountings, salinometers, steam traps, safety valves, air vents, priming, and deaerators. It aims to provide an overview of key components, parameters, and best practices for monitoring and maintaining industrial boilers.
This document discusses various topics related to boiler operation and safety including cold starting procedures, safeties, flame failure protection, water testing, safety valve operation, gauge glass checks, blowdown procedures, circulating pumps, differences between auxiliary and main boilers, drum levels, temperatures, water levels and their consequences, boiler mountings, salinometers, steam traps, safety valves, air vents, priming, and deaerators. It aims to provide an overview of key components, parameters, and best practices for monitoring and maintaining industrial boilers.
This document discusses various topics related to boiler operation and safety including cold starting procedures, safeties, flame failure protection, water testing, safety valve operation, gauge glass checks, blowdown procedures, circulating pumps, differences between auxiliary and main boilers, drum levels, temperatures, water levels and their consequences, boiler mountings, salinometers, steam traps, safety valves, air vents, priming, and deaerators. It aims to provide an overview of key components, parameters, and best practices for monitoring and maintaining industrial boilers.
2. Boiler safeties 3. Flame failure 4. Boiler water testing 5. Boiler safety valve lifting pr, easing gear 6. boiler operation 7. boiler accumulation pressure 8. Safety valve setting 9. Gauge glass checks 10. Gauge glass blow through 11. boiler blowdown procedure 12. why do we do boiler water test 13. use of boiler water circulating pump 14. difference between egb and aux boiler 15. Aux boiler – burner temp, exhaust gas temp 16. steam drum, water drum 17. circulating water outlet pr 18. FW circulating temp 19. boiler firing temp, egb temp 20. Why IG is not taken from M/E, but is taken from boiler 21. Composite boiler? 22. Boiler water level too high reasons, consequences 23. Boiler water level too low reasons, consequences 24. boiler mountings 25. use of salinometer cock 26. Why main steam stop valve is crack opened 27. Steam trap working 28. types of safety valve 29. if one gauge glass is not showing water, reasons, action 30. How to start EGB 31. Boiler air vent purpose 32. Boiler priming 33. Purpose of boiler de-aerator.