You are on page 1of 10

MP5S/MP5Y/MP5W/MP5M Series

High-performance, Digital Pulse Meter


Features
● 13 kinds of various operation modes :
Revolution, speed, frequency, absolute ratio, passing time,
error ratio, cycle, density, passing speed, error,
time width, length measurement, time difference, interval,
multiplication(MP5M Series have 11 operation modes)
● Various output function :
Relay output, NPN/PNP open collector output,
low speed serial output, BCD output,
PV transmission, RS485 communication output
● Various functions :
Prescale function, data monitoring function, hysteresis
function, peak value monitoring function, monitoring
delay function, auto zero time setting function,
lock setting function, display period delay function
● Max. display range : -19999 to 99999(MP5M : 0 to 99999)
● Various display units : rpm, rps, Hz, kHz, sec, min, m, mm, mm/ s, m/s,
m/min, m/h, ℓ/s, ℓ/min, ℓ/h, %, counts, etc.
● Selectable voltage input(PNP) or no voltage input(NPN)
● 50kHz high speed response
Please read “Caution for your safety” in operation
manual before using.

Ordering information
MP 5 S 4 N
Main output(Comparative value output) Sub output(Display value output)
S Type
N Indicator -
N Indicator -
1 NPN open collector quintuple output -
Y Type 2 PNP open collector quintuple output -
3 Indicator BCD Dynamic
4 Indicator PV transmission output(DC4-20mA)
5 Indicator RS485 communication output
N Indicator -
Output A Five relay(HH, H, GO, L, LL) -
1 Triple relay(H, GO, L) -
2 NPN open collector quintuple output BCD dynamic
3 PNP open collector quintuple output BCD dynamic
W Type
4 NPN open collector quintuple output PV transmission output(DC4-20mA)
5 PNP open collector quintuple output PV transmission output(DC4-20mA)
6 NPN open collector quintuple output Low speed serial output
7 PNP open collector quintuple output Low speed serial output
8 NPN open collector quintuple output RS485 communication output
9 PNP open collector quintuple output RS485 communication output
N Indicator -
Relay single(High-limit) output
M Type 1 -
+ NPN open collector output
Relay dual(High/Low-limit) output
2 -
+ NPN open collector output
Power supply 2 24VDC(Only for MP5Y-24)
4 100-240VAC 50/60Hz
S DIN W48×H48mm
Size Y DIN W72×H36mm
W DIN W96×H48mm
M DIN W72×H72mm
Digit
5 99999(5digit)
Series
MP Pulse meter
※PNP open collector output : Option

M-6
Pulse(Rate) Meter

Specifications(MP5S/MP5Y/MP5W Series) (A)


Photo
electric
Series MP5S-4N MP5Y-24 MP5Y-4 MP5W-4 sensor
Display method 7 Segment LED display(Zero blanking type) (B)
Character size W4 × H8mm W6.8 × H13.8mm Fiber
optic
Max. indication -19999 to 99999 sensor

100-240VAC 100-240VAC
Power supply 100-240VAC 50/60Hz 24VDC (C)
50/60Hz 50/60Hz Door/Area
sensor
Allowable operation voltage 90 to 110%
Power consumption Max. 7.5VA Max. 6W Max. 7VA Max. 6VA (D)
Proximity
Power for external sensor 12VDC ±10%, 80mA sensor
• Soild-state input : Max. 50kHz(Pulse width : Each over 10㎲)
Input frequency
• Contact input : Max. 45Hz(Pulse width : Over 11ms) (E)
Pressure
[Voltage input] High : 4.5-24VDC, Low : 0-1.0VDC, Input impedance : 4.5kΩ sensor
Input level [No-voltage input] Impedance at short-circuit : Max. 300Ω, Residual voltage : Max. 1V
Impedance at open-circuit : Min. 100kΩ (F)
• Mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz • Mode F3 : 0.02s to 3,200s Rotary
Measuring range encoder
• Mode F4, F5, F6 : 0.01s to 3,200s • Mode F11, F12, F13 : 0 to 4 ×10 Count
Measuring accuracy • Mode F1, F2, F7, F8, F9, F10 : F.S. ±0.05% rdg ±1digit (G)
(23 ±5℃) • Mode F3, F4, F5, F6 : F.S. ±0.01% rdg ±1digit Connector/
Socket
Display period 0.05 / 0.5 / 1 / 2 / 4 / 8sec.(It is same with period of output update.)
Number of revolution/Speed/Frequency(F1), Passing speed(F2), Cycle(F3), Passing time(F4), (H)
Time width(F5), Time defference(F6), Absolute ratio(F7), Error ratio(F8), Density(F9), Error(F10), Temp.
Operation mode controller
Length measurement(F11), Interval(F12), Multiplication(F13)
※Refer to the M-20 to 23 for the operation mode. (I)
SSR/
Prescale function Direct input method(0.000I×10-9 to 9.9999×109) Power
※1 controller
Hysteresis 0 to 9999
• Lock setting function
• Lock setting function (J)
• Monitoring delay function Counter
• Auto-Zero time setting
• Auto-zero time setting function
function
• Current output range selection(Current output type only)
• Time unit selection (K)
• Comparative output function(HH, H, GO, L, LL) Timer
function
Other functions • Time unit selection function
• Peak value monitoring
• Deviation memory function(F output mode applied only)
function (L)
• Peak value monitoring function Panel
• Memory protection
• Remote/Local switching function(Communication output type only) meter
function ※2
• Data bank switching function
(Mode F13 applied only) (M)
• Memory protection function(Mode F13 applied only) Tacho/
Speed/ Pulse
Triple relay 250VAC 3A resistive load meter
-
Main output

Quintuple relay 3a
(N)
NPN Open collector - Display
unit
(Quintuple)
12-24VDC 30mA Max. 12-24VDC 20mA max.
PNP Open collector
(O)
(Quintuple) Sensor
controller
NPN Open collector
BCD Dynamic - NPN Open collector
12-24VDC 30mA Max.
Sub output

12-24VDC 20mA max. (P)


Low speed serial output - - Switching
mode power
DC4-20mA Load 600Ω Max. DC4-20mA Load 600Ω supply
PV transmission -
(Response time : Max. 800ms) Max. (Q)
Stepper
RS485 communication - 31 channels, Mutual direction communication function motor&
Driver&Controller
Memory protection Non-volatile memory(Input : Min. 100,000 times)
Insulation resistance Min. 100MΩ(at 500VDC megger) Between charge part and non-charge part (R)
Graphic/
2000VAC 60Hz 1minute(Between terminals of AC power and case, Logic
Dielectric strength panel
Between terminals of AC power and measuring input terminals)
(S)
Impulse noise strength ±2000VAC R-phase, S-phase the square wave noise(pulse width : 1㎲) by the noise simulator, repeat frequency 60Hz Field
network
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hour device
Vibration
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes
(T)
Mechanical 300m/s²(approx. 30G) in each of X, Y, Z directions for 3 times Software
Shock
Malfunction 100m/s²(approx. 10G) in each of X, Y, Z directions for 3 times
Relay Malfunction - Min. 10,000,000 operations (U)
life cycle Mechanical - Min. 100,000 operations(250VAC 3A load current) Other

Environ Ambient temperature -10 to 50℃, storage : -20 to 60℃


-ment Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
Weight Approx. 199.5g(approx. 141.5g) Approx. 209g(approx. 117g) Approx. 301.5g(approx. 177g)
Approval -
※1: The hysteresis setting range is changed by the setting position of decimal point. (Refer to M-26 for hysteresis function.)
※2: Data bank switching function is in MP5W Series only. ※3: The weight with packaging and the weight in parentheses is only unit weight.

M-7
MP5S/MP5Y/MP5W/MP5M Series

Specifications(MP5M Series)
MP5M-4N MP5M-41 MP5M-42
Model
Indicator High-limit setting type High/Low-limit setting type
Display method 7 Segment LED display(Zero blanking), Character size : W4 X H8mm
Max. indication 0.0001 to 99999
Power supply 100-240VAC 50/60Hz
Allowable operation voltage 90 to 110%
Power consumption Approx. 7.5VA(240VAC) Approx. 8VA(240VAC)
Power for external sensor 12VDC ±10%, 80mA
• Solid-state input : Max. 50kHz(pulse width : over 10㎲)
Input frequency
• Contact input : Max. 45Hz(pulse width:over 11ms)
[Voltage input] High : 4.5-24VDC, Low : 0-1.0VDC, Input impedance : 4.5kΩ
Input level [No-voltage input] Impedance at short-circuit : Max. 300Ω, Residual voltage : Max. 1V
Impedance at open-circuit : Min. 100kΩ
• Mode F1, F2, F7, F8 : 0.0005Hz to 50kHz • Mode F3 : 0.02s to 3,200s
Measuring range
• Mode F4, F5, F6 : 0.01s to 3,200s • Mode F9, F10, F11 : 0 to 4 ×109 Count
Measuring accuracy(23 ±5℃) • Mode F1, F2, F7, F8 : F.S. ±0.05% rdg ±1digit • Mode F3, F4, F5, F6 : F.S. ±0.01% rdg ±1digit
Display period 0.05 / 0.5 / 1 / 2 / 4 / 8sec.(It is same with period of output update.)
Number of revolution/Speed/Frequency(F1), Passing speed(F2), Cycle(F3), Passing time(F4),
Operation mode Time width(F5), Time difference(F6), Absolute ratio(F7), Density(F8), Length measurement(F9),
Interval(F10), Multiplication(F11) ※Refer to M-20 to 23 for operation mode.
Prescale function Direct input method(0.0001×10-9 to 9.9999×109)
Hysteresis - 0 to 9999
• Lock setting function
• Monitoring delay function
• Lock setting function • Auto-Zero time setting function
• Lock setting function • Monitoring delay function • Time unit selection function
• Auto-Zero time setting function • Auto-Zero time setting function • Peak value monitoring function
• Time unit selection function • Time unit selection function • Memory protection function
Other function
• Peak value monitoring function • Peak value monitoring function (Mode F11 applied only)
• Memory protection function • Memory protection function • Comparative output function(H, L)
(Mode F11 applied only) (Mode F11 applied only) • Output mode selection function
• High-limit output function(H) (S, H, L, B, I, F)
• Deviation memory function
(F output mode applied only)
Main Relay 250VAC 3A resistive load 1c 250VAC 3A resistive load 1a×2
-
output NPN Open Collector 30VDC 100mA Max. 30VDC 100mA Max. ×2
Memory protection Non-volatile memory(Input : Min. 100,000 operations)
Approval
Unit weight Approx. 275g Approx. 310g Approx. 330g
※MP5S, MP5Y, MP5W have same function.
※Environment resistance is rated at no freezing or condensation.

Connections
MP5M Series
● MP5M-4N(Indicator) ● MP5M-41(High-limit setting type) ● MP5M-42(High/Low-limit setting type)

HOLD/ HOLD/ HOLD/


RESET RESET RESET

Black Black Brown Blue Black Black Brown Blue High Black Black Brown Blue High Low
8 9 10 11 12 13 14 8 9 10 11 12 13 14 8 9 10 11 12 13 14
INA INB +12V 0V INA INB +12V 0V INA INB +12V 0V

15 17 15 17 15 17

16 18 16 18 16 18
H L

1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
CONTACT OUT: CONTACT OUT:
250VAC 3A 250VAC 3A
SOURCE RESISTIVE LOAD SOURCE RESISTIVE LOAD SOURCE
100-240VAC 100-240VAC 100-240VAC
50/60Hz 50/60Hz 50/60Hz

M-8
Pulse(Rate) Meter

Connections (A)
Photo

MP5S Series electric


sensor

● MP5S-4N(Indicator) (B)
Fiber
optic
sensor
RESET
※1
/HOLD (C)
Door/Area
Black Black Brown Blue sensor

6 7 8 9 10 (D)
Proximity
INA INB +12V 0V sensor

(E)
Pressure
sensor

1 2 3 4 5 (F)

SOURCE ※1: It is used for RESET terminal when an operation mode Rotary
encoder

100-240VAC 50/60Hz is F13.(Refer to the M-20 to 23 for operation mode.)


(G)
Connector/
Socket
MP5Y Series
●MP5Y- N(Indicator) ●MP5Y- 4 to 5(Main/Sub output type) (H)
Temp.
controller

(I)
PCB SSR/
② ④ ⑥ ⑧ ⑩ Power
controller
Black
Black

(J)
Counter
Brown Blue ① ③ ⑤ ⑦ ⑨
1 2 3 4 5 6 7 1 2 3 4 5 6 7 ※Hirose Connector:
(K)
HIF3BD-10PA-2.54DS Timer
INA INB 0V +12V SOURCE INA INB 0V +12V SOURCE
HOLD/RESET 100-240VAC 50/60Hz HOLD/RESET 100-240VAC 50/60Hz
+ - + - (L)
※1 24VDC ※1 24VDC Panel
meter
※1: It is used for RESET terminal when an operation mode is F13. (Refer to M-20 to 23 for operation mode.)
(M)
Tacho/
Main output(Connector) Sub output(Connector) Speed/ Pulse
meter

● MP5Y- 1(NPN open collector output) ● MP5Y- 3(BCD dynamic output) (N)
MAIN OUT BCD OUT Display
unit
(NPN OPEN COLLECTOR:12-24VDC Max. 30mA) (NPN OPEN COLLECTOR:12-24VDC Max. 30mA)

A C D0 D2 D4 (O)
HH GO LL Sensor
controller
2 4 6 8 10
2 4 6 8 10
(P)
Switching
mode power
1 3 5 7 9 supply
1 3 5 7 9
(Q)
COM COM B D D1 D3
H L Stepper
motor&
Driver&Controller
● MP5Y- 4(PV transmission output)
● MP5Y- 2(PNP open collector output) DC4-20mA (R)
Graphic/
Load 600Ω Max. Logic
MAIN OUT (+) panel
(PNP OPEN COLLECTOR:12-24VDC Max. 30mA)
(S)
2 4 6 8 10 Field
HH GO LL network
device

2 4 6 8 10 1 3 5 7 9
(T)
Software
(-)
1 3 5 7 9 ● MP5Y- 5(RS485 communication output)
RS485 (U)
COM H L B(-) Other

2 4 6 8 10

1 3 5 7 9

※Main output type & sub output type : Customizable A(+)


RS485

M-9
MP5S/MP5Y/MP5W/MP5M Series
MP5W Series
● MP5W- N(Indicator) ● MP5W- A(Five relay output)

CONTACT OUT:
10 11 12 13 14 15 250VAC 3A 1a
Black Black Blue Brown HH H GO L LL COM RESISTIVE LOAD

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9 ● MP5W- 1(Triple relay output)


CONTACT OUT:
INA INB 0V ※1 0V +12V SOURCE 10 11 12 13 14 15 250VAC 3A 1a
HOLD/RESET + - 100-240VAC 50/60Hz RESISTIVE LOAD
24VDC H
BANK ※2 GO L
※1: It is used for RESET terminal when an operation mode is F13. 1 2 3 4 5 6 7 8 9
(Refer to the M-20 to 23)
※2: Refer to M-26 for BANK function.
※Main output type & sub output type : option
Main output+Sub output(Connector)
② ④⑥ ⑧ ⑩ ⑫ ⑭ ⑯ ⑱⑳
PCB
※Hirose connector pin header model of the unit
: HIF3BA-20PA-2.54DS
1 2 3 4 5 6 7 8 9 ① ③ ⑤ ⑦ ⑨ ⑪ ⑬ ⑮ ⑰ ⑲ ※Contact Hirose Electric to purchase socket and
wires of Hirose connector. [Socket : HIF3BA-20D-2.54R]
● MP5W- 2/ MP5W- 3(NPN/PNP open collector output + BCD output)
+24VDC
HH GO LL 30mA Max.
B D D1 D3 DOT COM2 HH GO LL
MAIN OUT 2 4 6 8 10 12 14 16 18 20 MAIN OUT 2 4 6
(NPN open collector (PNP open collector
: 12-24VDC Max. 20mA) 1 3 5 7 9 11 13 15 17 19 :12-24VDC Max. 20mA) 1 3 5
COM1 H L 0V A C D0 D2 D4 ※POL
COM1 H L
BCD OUT
(NPN open collector) ※POL signal is on when it is -(minus)
12-24VDC Max. 20mA display value
● MP5W- 4/ MP5W- 5(NPN/PNP open collector output + PV transmission output(DC4-20mA) output)
+24VDC
HH GO LL 30mA Max. (+) HH GO LL

MAIN OUT 2 4 6 8 10 12 14 16 18 20 2 4 6
MAIN OUT
(NPN open collector (PNP open collector
: 12-24VDC Max. 20mA) 1 3 5 7 9 11 13 15 17 19 :12-24VDC Max. 20mA) 1 3 5

COM1 H L 0V (-) COM1 H L


DC4-20mA Load 600Ω Max.

● MP5W- 6/ MP5W- 7(NPN/PNP open collector output + Low speed serial output)
+24VDC ※POL signal is on when it is - display value
HH GO LL 30mA Max. ※POL CLOCK LATCH HH GO LL

MAIN OUT 2 4 6 8 10 12 14 16 18 20 MAIN OUT 2 4 6


(NPN open collector (PNP open collector
: 12-24VDC Max. 20mA) 1 3 5 7 9 11 13 15 17 19 :12-24VDC Max. 20mA) 1 3 5
COM1 H L COM2 DATE
0V COM1 H L
SERIAL OUT
(NPN open collector)
12-24VDC Max. 20mA
● MP5W- 8/ MP5W- 9(NPN/PNP open collector output + RS485 communication output)
+24VDC
30mA RS485
HH GO LL Max. B(-) HH GO LL

2 4 6 8 10 12 14 16 18 20 MAIN OUT 2 4 6
MAIN OUT
(NPN open collector (PNP open collector
: 12-24VDC Max. 20mA) 1 3 5 7 9 11 13 15 17 19 :12-24VDC Max. 20mA) 1 3 5

COM1 H L COM1 H L
0V A(+)
RS485

M-10
Pulse(Rate) Meter

Dimensions (unit: mm)


(A)
Photo
electric

● MP5S Series ● Panel cut-out


sensor

(B)
● Bracket 48 10 90
Min. 55 Fiber
optic
sensor

+0.5
0
(C)

45.5
Door/Area
sensor

Min. 62
61

45
+0.5
45.5 0
(D)
Proximity
sensor

(E)
Pressure
sensor
● MP5Y Series
● Panel cut-out (F)
Rotary
encoder
85 ※There is no Min. 91
72 6 104 connector in
(G)
indicator. Connector/
Socket

31.5 + 00.5
Min. 40
36

30
(H)
+0.7
68 0
Temp.
controller
100
(I)
※Hirose connector : HIF3BD-10PA-2.54DS SSR/
Power
controller

● MP5W Series (J)


Counter

109 Sub Terminal


96 6 100 (There is no (K)
connector ● Panel cut-out Timer

in indicator.)
Min. 116 (L)
Panel
48

meter

46 + 0.6
0
(M)
Tacho/
Min. 52

Speed/ Pulse
+0.8 meter
Main Terminal 92 0

(N)
Display
unit

(O)
※Hirose connector(There is no connector in indicator.): Sensor
6 103 controller
HIF3BA-20PA-2.54DS
(P)
Switching
mode power
supply

(Q)
Stepper
motor&
Driver&Controller

(R)
Graphic/
Logic
panel

● MP5M Series (S)


Field

85 ● Panel cut-out network


device

72 14.2 111.8 Min. 91


(T)
Software
+0.7
0 68

(U)
Other
Min. 91
67

+0.7
68 0

M-11
MP5S/MP5Y/MP5W/MP5M Series

Input specifications
Input signal
● Solid-state input
• Input frequency : 50kHz Max. Min. 10㎲
Standard duty ratio of input signal is 1:1,
High
ON/OFF pulse width should be over 10㎲.
• Input voltage level : High → 4.5-24VDC, Low → 0-1.0VDC Low
ON OFF *T : 1cycle of input signal
● Relay contact input
• Input frequency : 45Hz Max. T
ON/OFF pulse width should be over 11ms.
• Relay contact specification : Please use a relay contact that can carry the load current(Min. 12VDC 2mA).

Input type
MP5 has NPN input and PNP input and it is able to select in Parameter group 1.
● When it is NPN input type
②NPN voltage ③NPN open collector
①Contact output type sensor output type sensor MP5 Series
+12V
Sensor circuit

Sensor circuit

Main circuit
4.5kΩ
IN

0V(COM)

● When it is PNP input type


②PNP voltage ③PNP open collector
①Contact output type sensor output type sensor MP5 Series
+12V
Sensor circuit

Sensor circuit

Main circuit
IN

4.5kΩ
0V(COM)

※O·C is Open Collector output.

Output specifications(MP5Y/ MP5W Series)


Transistor output Ex)When BCD dynamic output is 125.89
● Output : Comparative output or alarm output(Refer to M-24 104 Digit 100 Digit
page " Output mode") PV display 1 2 5. 8 9
● Output type : NPN open collector value
● Rated load voltage : 12-24VDC
A H Ⓛ H Ⓛ H Ⓛ H
● Max. load current : 30mA
BCD dynamic output(Negative logic) B H H Ⓛ H H H H
● Output : Display value
● Output signal : BCD
C H H H Ⓛ H H H
Data
BCD Data(A, B, C, D, DOT) ← A : Lowest bit
Dot : Highest bit D H H H H Ⓛ Ⓛ H
Digit Data(D0, D1, D2, D3, D4) ← D0 : Lowest digit
D4 : Highest digit DOT H H H Ⓛ H H H
※There is no DOT data output in MP5Y- 3,
H H
therefore decimal point should be mark
D0
in first display plate. H 0.1ms
● Output type : NPN open collector D1
H
● Rated load voltage : 12-24VDC Digit D2
● Max. load current : 30mA(MP5Y)/ 20mA(MP5W) H
D3
H
D4
5ms 7.8ms
39ms

M-12
Pulse(Rate) Meter
Low speed serial output(Negative logic) (A)
Photo
● Output : Display value electric
sensor
● Output signal : Clock, Data, Latch
● Clock cycle : 50Hz (B)
Fiber
● Output CLK bit : 25 bit optic
sensor
● Output Data bit : 25 bit
● Output form : NPN open collector (C)
Door/Area
● Rated load voltage : 12-24VDC sensor

● Max. load current : 30mA(MP5Y)/ 20mA(MP5W)


(D)
Proximity
● Serial transmission time diagram sensor

C1 C2 C3 C23 C24 C25 C1 C2 C3 C4 (E)


CLK Pressure
sensor

20ms (F)
Rotary
encoder
Data D1 D2 D3 D23 D24 D25 D1 D2 D3 D4
20㎲ (G)
Connector/
Socket
5ms
(H)
Latch Temp.
controller

● Data output order when it is serial transmission (I)


SSR/
Power
Start controller

Clock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 (J)
Counter
ordering Shift
(K)
Timer

Segment
Data ordering
MSB(4)

MSB(3)

MSB(2)

MSB(1)
MSB(5)

LSB(5)

LSB(4)

LSB(3)

LSB(2)

LSB(1)
(L)
DP(3)

DP(2)

DP(1)
DP(5)

DP(4)

Panel
meter

Decimal Data Decimal Data Decimal Data Decimal Data Decimal Data (M)
Tacho/
point point point point point Speed/ Pulse
meter

104 Digit 103 Digit 102 Digit 101 Digit 100 Digit (N)
Display
unit

PV transmission output(DC4-20mA)
● Application : Transmit the measured value (O)
Sensor
● Function : This function is to transmit DC4-20mA converted Display
controller

from measured display value between High limit output(FS-H) value (P)
and Low limit (FS-L). FS-H Switching
mode power
● Range of High/Low limit output setting supply

• High limit setting range (FS-H) If set FS-L and FS-H in FS-L (Q)
From min. to max within range of measurement certain section, the output will be Stepper
motor&
• Low limit setting range (FS-L) DC4-20mA. Driver&Controller

From min. to max within range of measurement (R)


Graphic/
(FS-H ≥ FS-L + 1 digit) 20mA Logic
panel
● Load resistance : Max. 600Ω The resolution will be lower when
● Resolution : 8000-division the display value is narrower than 4mA (S)
Field
8,000-division. network
device
RS485 communication output
● Address : 0 to 99 address (T)
Software
● Transmission speed(Baud rate) : 2400/4800/9600 bps
● Transmission code : ASCII
● Parity Bit : No (U)
Other
● Data Bit : 8 Bit
● Stop Bit : 1 Bit
● Communication items
MP5W ← PC : Comparative value of each bank data, prescale value and peak value, RESET control
MP5W → PC : Comparative value of each bank data, prescale value and peak value, display value
※Refer to the M-26 for communication data.

M-13
MP5S/MP5Y/MP5W/MP5M Series

Parameter group chart for model


● The parameter has different mode according to each model, therefore refer to " Parameter group chart of operation
mode" and " Parameter".
● ◐ : When selecting the operation mode, the parameter will be displayed.
× : When selecting the operation mode, the parameter will not be displayed.
MP5S-4N MP5Y- MP5W- MP5W- MP5W-
Model MP5W-4A
MP5Y-4N 41 MP5Y- MP5Y- MP5Y- MP5W- 44 46 48 MP5M- MP5M-
MP5W-42
MP5W-4N MP5Y- 43 44 45 41 MP5W- MP5W- MP5W- 41 42
Parameter MP5W-43
MP5M-4N 42 45 47 49

PSt;;
Parameter group 0

PSt ;
PSt L
PStLL
:PEK
lPEK
MODE
IN-A
IN-B
Parameter group 1

OVT-T
;YS
GVArD fDEFY
GVArD STArT
AUToA
AUToB
MEMO
pBANY
DOT
tVNT
PSt;;
Parameter group 2

PSt ;
PSt L
PStLL
PScaH
PScaY
PScbH
PScbY
DISpT
FS-;
Parameter group 3

FS-L
ADDR
BPS
REMOT
LOC
※ : Data bank(pBANK)setting is available in only MP5W-☐N.

Monitoring delay operation function chart by each output mode


OVT-T STARD OVT-; OVT-L OVT-B OVT-I OVT-F
Comparative output limit function
Starting correction timer function

M-14
Pulse(Rate) Meter

Parameter group chart for operation mode (A)


Photo
electric
● Parameter display are different according to each operation mode, refer to " Parameter" part. sensor

● " " : When select the operation mode, the parameter will be displayed. (B)
"×" : When select the operation mode, the parameter will not be displayed. Fiber
optic
● " " : It is only able to set NPn:For PNp:F for IN-B sensor type in F11, F12, F13 of operation mode. sensor

Parameter display F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 (C)


Door/Area
sensor

PSt;;
(D)
PSt ; Proximity
sensor

Parameter PSt L
(E)
group 0
PStLL Pressure
sensor

:PEK
(F)
lPEK Rotary
encoder

MODE (G)
Connector/
IN-A Socket

IN-B (H)
Temp.
OVT-T controller

Parameter ;YS (I)


SSR/
group 1 Power
GVArD fDEFY controller

GVArD STArT (J)


Counter
AUToA
AUToB (K)
Timer
MEMO
pBANK (L)
Panel
meter
DOT
(M)
tVNT Tacho/
Speed/ Pulse
meter
PSt;;
PSt ; (N)
Display
unit
Parameter PSt L
group 2
PStLL (O)
Sensor
controller
PScaH
(P)
PScaY Switching
mode power
supply
PScbH
(Q)
PScbY Stepper
motor&
Driver&Controller
DISpT
(R)
Graphic/
FS-; Logic
When it is PV transmission output, it operates in all mode. panel

FS-L (S)
Field
Parameter ADDR network
device
group 3
BPS When it is RS485 communication output, it operates in all mode.
(T)
REMOT Software

(U)

Operation mode by each Series


Other

Operation mode Frequency


Passing Passing Time Time Absolute Error Length
rotation Cycle Density Error Interval Multiplication
speed time width difference ratio ratio measurement
Series name speed
MP5S, MP5Y, MP5W F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13
MP5M F1 F2 F3 F4 F5 F6 F7 × F8 × F9 F10 F11

M-15