Shading Report produced by Bangun Solar Global

Design 3 Amazana Apartemen, -6.266644, 106.671365


 Shading Heatmap

1,764, (100%)

1,631, (93%)

1,499, (85%)

1,367, (78%)

1,235, (70%)

 Shading by Field Segment

Description Tilt Azimuth Modules Nameplate Shaded Irradiance AC Energy TOF2 Solar Access Avg TSRF 2
Field Segment 1 10.0° 0.0° 75 33.0 kWp 1,697.3kWh/m2 45.6 MWh1 99.9% 96.3% 96.2%
Totals, weighted by kWp 75 33.0 kWp 1,697.3kWh/m2 45.6 MWh 99.9% 96.3% 96.2%
1approximate, varies based on inverter performance
2 based on location Optimal POA Irradiance of 1,763.8kWh/m2 at 11.8° tilt and 5.0° azimuth

 Solar Access by Month

Description jan feb mar apr may jun jul aug sep oct nov dec
Field Segment 1 99% 99% 99% 97% 91% 91% 91% 94% 99% 99% 99% 99%
Solar Access, weighted by kWp 99.2% 99.2% 99.2% 96.5% 91.5% 90.7% 91.0% 93.9% 99.1% 99.2% 99.1% 99.1%
AC Power (kWh) 3,347.0 3,135.7 3,914.8 3,846.4 3,838.9 3,626.7 3,988.6 4,290.8 4,431.7 4,143.7 3,669.5 3,365.8

© 2023 Aurora Solar 1/2 October 27, 2023


Shading Report produced by Bangun Solar Global

 Monthly Production  Sources of System Loss

6k
AC System:
System: 0.1%
Shading: 3.7%
Shading:
Inverters: 1.6%
Inverters:

4k Clipping: 0.0%
Clipping:

Wiring: 0.5%
Wiring:
kWh

Reflection: 3.2%
Reflection:
Mismatch: 3.2%
Mismatch:

2k

Soiling: 2.0%
Soiling:

Temperature: 8.0%
Temperature:
0 Irradiance: 1.6%
Irradiance:
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

 Southwestern Angle  Southeastern Angle

© 2023 Aurora Solar 2/2 October 27, 2023