Annual Production Report produced by andi saputra

Design 1 PLTS 100, Palembang


 Report  System Metrics  Project Location

Project Name PLTS 100 Design Design 1

Project Address Palembang Module DC


178.5 kW
Nameplate
andi saputra
Prepared By Inverter AC 200.0 kW
andisaputrawu@gmail.com
Nameplate Load Ratio: 0.89

Annual
223.6 MWh
Production

Performance
82.2%
Ratio

kWh/kWp 1,252.5

TMY, 10km Grid, meteonorm


Weather Dataset
(meteonorm)

6a74034394-483c6c6be2-aa4cb1d45e-
Simulator Version
4e9afde0e0

 Monthly Production  Sources of System Loss

30k
AC System:
System: 0.2% Shading: 0.8%
Shading:

Inverters: 1.4%
Inverters:
Reflection: 3.3%
Reflection:
Clipping: 0.0%
Clipping:
20k
Wiring: 0.4%
Wiring:
kWh

Mismatch: 3.4%
Mismatch:

Soiling: 2.0%
Soiling:
10k

Irradiance: 0.8%
Irradiance:

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Temperature: 6.9%
Temperature:

© 2023 Aurora Solar 1/3 November 21, 2023


Annual Production Report produced by andi saputra

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,526.8 Weather Dataset TMY, 10km Grid, meteonorm (meteonorm)
POA Irradiance 1,524.5 -0.2%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,512.0 -0.8%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,461.5 -3.3%
Irradiance after Soiling 1,432.3 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,432.3 0.0% Rack Type a b Temperature Delta
Nameplate 255,833.2 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 253,898.1 -0.8% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 236,352.5 -6.9% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 228,264.1 -3.4% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 227,257.9 -0.4%
J F M A M J J A S O N D
Constrained DC Output 227,257.4 0.0% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 224,075.8 -1.4%
Irradiation Variance 5%
Energy to Grid 223,576.3 -0.2%
Temperature Metrics Cell Temperature Spread 4° C

Avg. Operating Ambient Temp 28.7 °C Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 37.5 °C AC System Derate 0.50%
Simulation Metrics Uploaded
Module Characterization
Operating Hours 4496 Module By
Characterizations TSM-500DE18M(II) Spec Sheet
Solved Hours 4496
HelioScope
(Trina Solar) Characterization, PAN
Uploaded
Device Characterization
Component By
Characterizations SUN2000-100KTL-M1 (380/400)
HelioScope Spec Sheet
(Huawei)

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
SUN2000-100KTL-M1 (380/400) 2 (200.0 Wiring Zone - 5-20 Along Racking
Inverters
(Huawei) kW)
AC Home
1/0 AWG (Aluminum) 2 (424.4 ft)  Field Segments
Runs
20 (2,915.1 Intrarow Frame
Strings 10 AWG (Copper) Description Racking Orientation Tilt Azimuth Frames Modules Power
ft) Spacing Size

Trina Solar, TSM-500DE18M(II) 357 (178.5 Fixed Landscape 103.5


Module Baru 1 10° 70° 2.0 ft 1x1 207 207
(500W) kW) Tilt (Horizontal) kW
Field Segment Fixed Landscape
10° 70° 2.0 ft 1x1 150 150 75.0 kW
2 Tilt (Horizontal)

© 2023 Aurora Solar 2/3 November 21, 2023


Annual Production Report produced by andi saputra

 Detailed Layout

© 2023 Aurora Solar 3/3 November 21, 2023