You are on page 1of 10

Annual Production Report produced by Shanu Kannoth

Design 1 200kw PDDP Project 5CG6+89C, Nedumbassery, Kerala 683546, India


Project Details System Metrics Project Location

5CG6+89C, Nedumbassery, Kerala 683546, Design Design 1


Address
India
Module DC
229.8 kW
Owner Shanu Kannoth Nameplate

Last Shanu Kannoth Inverter AC 200.0 kW


Modified 5 minutes ago Nameplate Load Ratio: 1.15

(10.175551864212755, 76.410881923886) Annual


Location 393.1 MWh
(GMT 5.5) Production

Profile Default Commercial Performance


81.3%
Ratio

kWh/kWp 1,710.9

TMY, 10km Grid, meteonorm/suny high resolution


Weather Dataset
(meteonorm)

Production
Energy Consumption System Loss
50K
AC System: 0.3% Shading: 1.1%
Inverter: 1.5%
40K
Clipping: 0.0% Reflection: 3.1%

Wiring: 0.9%
30K
kWh

Mismatch: 3.2%
20K
Soiling: 2.0%

10K
Irradiance: 0.3%

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Production Temperature: 7.9%

Annual Production Condition Set

Description Output % Delta Description Condition Set 1

Irradiance Annual Global Horizontal Irradiance 2,054.2 - Weather Dataset TMY10km Gridmeteonorm/suny high resolution(meteonorm)
(kWh/m2)
Adjusted Global Horizontal Irradiance 2,054.2 0.0% Solar Angle Location Meteo Lat/Lng

POA Irradiance 2,105.2 2.5% Transposition Model Perez Model

Shaded Irradiance 2,083.0 -1.1% Temperature Model Sandia Model

Irradiance After Reflection 2,018.3 -3.1% Rack Type a b Temperature Delta

Irradiance After Soiling 1,977.9 -2.0% Fixed Tilt -3.56 -0.08 3.0°C

Total Collector Irradiance 1,977.9 -0.0% Temperature Model Parameters Flush Mount -2.81 -0.05 0.0°C

Nameplate 454,511.0 - East-West -3.56 -0.08 3.0°C

Output at Irradiance Levels 453,050.5 -0.3% Carport -3.56 -0.08 3.0°C

Output at Cell Temperature Derate 417,176.7 -7.9% J F M A M J J A S O N D


Soiling (%)
Energy Output After Mismatch 403,883.7 -3.2% 2 2 2 2 2 2 2 2 2 2 2 2
(kWh) Optimal DC Output 400,169.6 -0.9% Irradiation Variance 5.0%

Constrained DC Output 400,164.4 -0.0% Cell Temperature Spread 4.0°C

Inverter Output 394,159.6 -1.5% Module Binning Range -2.5% to 2.5%

Energy to Grid 393,107.1 -0.3% AC System Derate 0.50%

Temperature Metrics Type Component Characterization

Avg. Operating Ambient Temp 28.5°C TSM-DE21 640 (Trina Spec Sheet
Module
Solar) Characterization,PAN
Avg. Operating Cell Temp 40.7°C
TSM-DE21 640 (Trina Spec Sheet
Simulation Metrics Module
Solar) Characterization,PAN
Operating Hours 4,579
TSM-DE21 640 (Trina Spec Sheet
Module
Solved Hours 4,579 Solar) Characterization,PAN

Pending Hours - TSM-DE21 640 (Trina Spec Sheet


Module
Solar) Characterization,PAN
Error Hours -
Annual Production Report produced by Shanu Kannoth

Design BOM Monthly Shading

Component Type Quantity Month GHI (kWh/m2) POA (kWh/m2) Shaded (kWh/m2) Nameplate (kWh) Grid (kWh)

240 mm2 (Aluminum) AC Home Runs 4 January 184.2 204.4 199.0 43,641.4 37,219.3

MAC 50KTL3-X LV Inverters 4 February 187.7 201.3 199.8 43,790.5 37,466.3

TSM-DE21 640 Modules 359 March 207.9 213.0 212.1 46,452.8 39,688.2

10 AWG (Copper) Strings 17 April 187.0 184.1 183.1 39,946.2 34,388.7

May 176.6 168.8 167.8 36,424.9 31,590.7

June 143.2 136.1 135.2 29,320.8 25,809.0

July 147.6 141.1 140.1 30,404.1 26,819.4

August 165.4 161.1 160.1 34,859.1 30,555.4

September 171.0 172.1 171.1 37,265.9 32,487.2

October 158.7 165.5 164.2 35,761.7 31,122.8

November 159.8 173.5 171.1 37,359.2 32,269.6

December 165.1 184.3 179.5 39,284.2 33,690.5

Design Render
Annual Production Report produced by Shanu Kannoth

Project Location Design Wiring Zone

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 6 - 23 Along Racking

Field Segments

Description Racking Orientation Tilt Azimuth Intrarow Spacing Frame Size Frames Modules Power

Field Segment 1 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 22 22 14.08 kW

Field Segment 2 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 40 40 25.60 kW

Field Segment 3 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW

Field Segment 4 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW

Field Segment 5 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 45 45 28.80 kW

Field Segment 6 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 40 40 25.60 kW

Field Segment 7 Fixed Tilt Portrait (Vertical) 10° 180° 6.0 ft 2x1 18 36 23.04 kW

Field Segment 8 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW

Field Segment 8 (copy) Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW

Field Segment 10 Fixed Tilt Landscape (Horizontal) 10° 180° 0.5 ft 1x1 80 80 51.20 kW
Shading Report produced by Shanu Kannoth

PDDP site 200kw PDDP Project, 5CG6+89C, Nedumbassery, Kerala 683546, India
Shading Heatmap

2,124, (100%)

1,964, (93%)

1,805, (85%)

1,646, (78%)

1,487, (70%)

© 2023 Aurora Solar 1/3 August 12, 2023


Shading Report produced by Shanu Kannoth

Shading by Field Segment


2
Description Tilt Azimuth Modules Nameplate Shaded Irradiance AC Energy TOF2 Solar Access Avg TSRF

Field Segment 1 10.0° 180.0° 34 21.8 kWp 2,093.0kWh/m2 37.3 MWh1 99.1% 99.4% 98.6%

Field Segment 1 (copy) 10.0° 180.0° 33 21.1 kWp 2,093.0kWh/m 2


36.2 MWh 1
99.1% 99.4% 98.6%

Field Segment 3 10.0° 180.0° 33 21.1 kWp 2,092.8kWh/m2 36.2 MWh1 99.1% 99.4% 98.5%

Field Segment 4 10.0° 180.0° 30 19.2 kWp 2,092.9kWh/m2 32.9 MWh1 99.1% 99.4% 98.6%

Field Segment 5 10.0° 180.0° 36 23.0 kWp 2,094.0kWh/m2 39.5 MWh1 99.1% 99.5% 98.6%

Field Segment 8 10.0° 180.0° 24 15.4 kWp 2,091.4kWh/m 2


26.3 MWh 1
99.1% 99.3% 98.5%

Field Segment 8 (copy) 10.0° 180.0° 24 15.4 kWp 2,091.8kWh/m 2


26.3 MWh 1
99.1% 99.4% 98.5%

Field Segment 7 10.0° 180.0° 33 21.1 kWp 2,076.7kWh/m 2


36.0 MWh 1
99.1% 98.6% 97.8%

Field Segment 6 10.0° 180.0° 30 19.2 kWp 2,085.9kWh/m 2


32.8 MWh 1
99.1% 99.1% 98.2%

Field Segment 10 10.0° 180.0° 36 23.0 kWp 2,079.8kWh/m2 39.3 MWh1 99.1% 98.8% 97.9%

Totals, weighted by kWp 313 200.3 kWp 2,089.0kWh/m2 342.7 MWh 99.1% 99.2% 98.4%
1
approximate, varies based on inverter performance
2
based on location Optimal POA Irradiance of 2,123.6kWh/m2 at 18.9° tilt and 175.0° azimuth

Solar Access by Month

Description jan feb mar apr may jun jul aug sep oct nov dec

Field Segment 1 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%

Field Segment 1 (copy) 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%

Field Segment 3 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%

Field Segment 4 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%

Field Segment 5 100% 99% 100% 100% 100% 99% 99% 100% 100% 99% 99% 99%

Field Segment 8 100% 99% 100% 100% 100% 99% 99% 100% 100% 99% 99% 98%

Field Segment 8 (copy) 100% 99% 100% 100% 100% 100% 99% 100% 100% 99% 99% 98%

Field Segment 7 95% 99% 100% 99% 99% 99% 99% 99% 99% 99% 98% 97%

Field Segment 6 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 98% 97%

Field Segment 10 96% 99% 100% 100% 99% 99% 99% 99% 99% 99% 98% 97%

Solar Access, weighted by kWp 98.7% 99.2% 99.6% 99.5% 99.5% 99.4% 99.3% 99.4% 99.4% 99.3% 99.0% 98.6%

AC Power (kWh) 32,905.0 32,517.0 34,490.0 29,908.5 27,467.3 22,442.9 23,322.9 26,570.1 28,257.1 27,070.9 28,099.7 29,601.0

© 2023 Aurora Solar 2/3 August 12, 2023


Shading Report produced by Shanu Kannoth

Monthly Production Sources of System Loss

40k
AC System: 0.3% Shading: 0.8%
Inverters: 1.5% Reflection: 3.1%
30k
Clipping: 0.0%
Wiring: 1.1%
kWh

20k Mismatch: 3.3%


Soiling: 2.0%

Irradiance: 0.3%
10k

0
Temperature: 7.9%
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

GHI POA Shaded Nameplate Grid


Month
(kWh/m2) (kWh/m2) (kWh/m2) (kWh) (kWh)

January 184.2 204.4 201.9 38,575.2 32,905.0


February 187.7 201.3 199.7 38,166.7 32,517.0
March 207.9 213.0 212.1 40,498.7 34,490.0
April 187.0 184.1 183.2 34,830.4 29,908.5
May 176.6 168.8 167.9 31,760.6 27,467.3
June 143.2 136.1 135.2 25,567.1 22,442.9
July 147.6 141.1 140.1 26,511.9 23,322.9
August 165.4 161.1 160.2 30,396.0 26,570.1
September 171.0 172.1 171.1 32,494.1 28,257.1
October 158.7 165.5 164.3 31,195.9 27,070.9
November 159.8 173.5 171.7 32,693.3 28,099.7
December 165.1 184.3 181.7 34,671.3 29,601.0

Southwestern Angle Southeastern Angle

© 2023 Aurora Solar 3/3 August 12, 2023


Mono Multi Solutions

PRODUCT: TSM-DEG21C.20
BIFACIAL DUAL GLASS MONOCRYSTALLINE MODULE POWER RANGE: 640-665W

665W 0~+5W 21.4%


MAXIMUM POWER OUTPUT POSITIVE POWER TOLERANCE MAXIMUM EFFICIENCY

High customer value


• Lower LCOE (Levelized Cost Of Energy), reduced BOS (Balance of
System) cost, shorter payback time
• Lowest guaranteed first year and annual degradation;
• Designed for compatibility with existing mainstream system
components

High power up to 665W


• Up to 21.4% module efficiency with high density interconnect
technology
• Multi-busbar technology for better light trapping effect, lower series
resistance and improved current collection

High reliability
• Minimized micro-cracks with innovative non-destructive cutting
technology
• Ensured PID resistance through cell process and module material
control
• Resistant to harsh environments such as salt, ammonia, sand, high
temperature and high humidity areas
• Mechanical performance up to 5400 Pa positive load and 2400 Pa
negative load

High energy yield


• Excellent IAM (Incident Angle Modifier) and low irradiation
performance, validated by 3rd party certifications
• The unique design provides optimized energy production under
inter-row shading conditions
• Lower temperature coefficient (-0.34%) and operating temperature
• Up to 25% additional power gain from back side depending on albedo

Trina Solar’s Vertex Bifacial Dual Glass Performance Warranty


100% 98.0%
Guaranteed Power

90%

85.0%

Years 5 10 15 20 25 30

Comprehensive Products and System Certificates


IEC61215/IEC61730/IEC61701/IEC62716/UL61730
ISO 9001: Quality Management System
ISO 14001: Environmental Management System
××××××××××

ISO14064: Greenhouse Gases Emissions Verification


RECYCLABLE
PACKAGING
EU-28 WEEE
COMPLIANT
ISO45001: Occupational Health and Safety Management System
BIFACIAL DUAL GLASS MONOCRYSTALLINE MODULE

DIMENSIONS OF PV MODULE(mm) I-V CURVES OF PV MODULE(645 W)


1303 20
1303
35 1264 18 1000W/mS

Se rial
16
num be r

14 800W/mS

12

Current (A)
600W/mS
10

8
4-Φ9×14 400W/mS
6
Installing Hole
4
200W/mS
A A 2

0 10 20 30 40 50
4-Φ7×10
Installing Hole Voltage(V)

P-V CURVES OF PV MODULE(645W)


2384

2384
1400
700
400
600
1000W/mS
500

Power (W)
800W/mS
400

600W/mS
300

200 400W/mS

8-Φ4.3 100 200W/mS


Grounding Hole
B

0 10 20 30 40 50
12-Drain Hole
Voltage(V)
B

Front View Back View


Silicon Sealant I-V CURVES OF PV MODULE(645 W)
Silicon Sealant
20
Laminate Laminate
18

16

14
12

Current (A)
Cell temp.=10℃
35

35

10
Cell temp.=25℃
8
Frame Frame Cell temp.=40℃
6
Cell temp.=55℃
4
Cell temp.=70℃
2

30 30
0 10 20 30 40 50

A-A B-B Voltage(V)

ELECTRICAL DATA (STC) MECHANICAL DATA

Peak Power Watts-PMAX (Wp)* 640 645 650 655 660 665 Solar Cells Monocrystalline

No. of cells 132 cells


Power Tolerance-PMAX (W) 0 ~ +5
Module Dimensions 2384×1303×35 mm (93.86×51.30×1.38 inches)
Maximum Power Voltage-VMPP (V) 37.3 37.5 37.7 37.9 38.1 38.3
Weight 38.7 kg (85.3 lb)
Maximum Power Current-IMPP (A) 17.19 17.23 17.27 17.31 17.35 17.39
Front Glass 2.0 mm (0.08 inches), High Transmission, AR Coated Heat Strengthened Glass
Open Circuit Voltage-VOC (V) 45.1 45.3 45.5 45.7 45.9 46.1 Encapsulant material POE/EVA

Short Circuit Current-ISC (A) 18.26 18.31 18.35 18.40 18.45 18.50 Back Glass 2.0 mm (0.08 inches), Heat Strengthened Glass (White Grid Glass)

Module Efficiency η m (%) 20.6 20.8 20.9 21.1 21.2 21.4 Frame 35mm(1.38 inches) Anodized Aluminium Alloy

J-Box IP 68 rated
STC: Irrdiance 1000W/m2, Cell Temperature 25ºC, Air Mass AM1.5. *Measuring tolerance: ±3%.

Electrical characteristics with different power bin (reference to 10% Irradiance ratio) Cables Photovoltaic Technology Cable 4.0mmS (0.006 inchesS),
Portrait: 280/280 mm(11.02/11.02 inches)
Total Equivalent power -PMAX (Wp) 685 690 696 701 706 712 Length can be customized
Maximum Power Voltage-VMPP (V) 37.3 37.5 37.7 37.9 38.1 38.3
Connector MC4 EVO2 / TS4*
Maximum Power Current-IMPP (A) 18.39 18.44 18.48 18.52 18.56 18.60 *Please refer to regional datasheet for specified connector.

Open Circuit Voltage-VOC (V) 45.1 45.3 45.5 45.7 45.9 46.1
TEMPERATURE RATINGS MAXIMUMRATINGS
Short Circuit Current-ISC (A) 19.54 19.59 19.63 19.69 19.74 19.79
NOCT(Nominal Operating Cell Temperature) 43°C (±2°C) Operational Temperature -40~+85ºC
Irradiance ratio (rear/front) 10% Temperature Coefficient of PMAX - 0.34%/°C Maximum System Voltage 1500V DC (IEC)
Power Bifaciality:70±5%. Temperature Coefficient of VOC - 0.25%/°C 1500V DC (UL)

ELECTRICAL DATA (NOCT) Temperature Coefficient of ISC 0.04%/°C Max Series Fuse Rating 35A

Maximum Power-PMAX (Wp) 484 488 492 495 499 504


WARRANTY PACKAGING CONFIGUREATION
Maximum Power Voltage-VMPP (V) 34.7 34.9 35.1 35.2 35.4 35.6
12 year Product Workmanship Warranty Modules per box: 31 pieces
Maximum Power Current-IMPP (A) 13.94 13.98 14.01 14.05 14.10 14.16
30 year Power Warranty Modules per 40’ container : 558 pieces
Open Circuit Voltage-VOC (V) 42.5 42.7 42.9 43.0 43.2 43.4
2% first year degradation
Short Circuit Current-ISC (A) 14.71 14.75 14.79 14.83 14.87 14.91 0.45% Annual Power Attenuation

NOCT: Irradiance at 800W/mS, Ambient Temperature 20°C, Wind Speed 1m/s. (Please refer to product warranty for details)

CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.
© 2021 Trina Solar Co.,Ltd, All rights reserved, Specifications included in this datasheet are subject to change without notice.
Version number: TSM_EN_2021_A www.trinasolar.com
MAC 30~60KTL3-X LV
· 3 MPPTs
· Smart diagnosis
· High efficiency up to 98.8%
· Local WIFI connection
· OLED display and touch button
· AC&DC type II SPD
· Data storage up to 25 years
· DC side 2 in 1 connection enabled

www.ginverter.com
Longteng
Community,
Shiyan, Baoan
District,
Shenzhen,
Datasheet MAC 30KTL3-X LV MAC 40KTL3-X LV MAC 50KTL3-X LV P.R.China.MAC
T: + 60KTL3-X LV
86 755 2747
1900 F: + 86 755 2749 1460 E: info
Inputu data (DC)
Max. recommended PV
power(for module STC) 45000W 60000W 75000W 90000W

Max.DC voltage 1100V

Start voltage 250V


Nominal voltage 600V

MPPT voltage range 200V-1000V

No. of MPP trackers 3

No. of PV strings per MPP tracker 3/3/2 3/3/3 4/3/3 4/4/4


Max. input current per MPP tracker 37.5A/37.5A/25A 37.5A/37.5A/37.5A 50A/37.5A/37.5A 50A/50A/50A
Max. short-circuit current
per MPP tracker 45A 45A 55A 55A

Output data (AC)


Rated AC output power 30000W 40000W 50000W 60000W
Max. AC apparent power 33300VA 44400VA 55500VA 66600VA
Nominal AC voltage(range*) 230V/400V (340-440V)
AC grid frequency(range*) 50/60 Hz (45-55Hz/55-65 Hz)
Max. output current 48.3A 64.4A 80.5A 96.6A

Adjustable power factor 0.8leading 0.8lagging

THDi <3%
AC grid connection type 3W+N+PE

Efficiency
Max. efficiency 98.7% 98.7% 98.7% 98.8%
European efficiency 98.4% 98.5% 98.5% 98.5%
MPPT efficiency 99.9%

Protection devices
DC reverse polarity protection Yes
DC switch Yes
AC/DC surge protection Type II / Type II
Insulation resistance monitoring Yes
AC short-circuit protection Yes
Ground fault monitoring Yes
Grid monitoring Yes
Anti-islanding protection Yes
Residual-current monitoring unit Yes

General data
Dimensions(W / H / D) 680/508/281mm
Weight 52kg
Operating temperature range –25°C ... +60°C

Noise emission(Typical) ≤60dB(A)

Nighttime power consumption < 1W


Topology Transformerless

Cooling Smart air cooling

Protection degree IP65

Relative humidity 0~100%

Altitude 4000m

DC connection H4/MC4(Optional)

AC connection Cable gland+OT terminal

Display OLED+LED/WIFI+APP
Interfaces: RS485 / USB
Yes/Yes /Optional/Optional/Optional
/WiFi/ GPRS / RF

Warranty: 5 years / 10 years Yes /Optional

CE, IEC62116, IEC61727, IEC 60068, IEC 61683, IEC60529, KSC8565

* The AC voltage range and frequency


range may vary depending on specific
country grid standard. All specifications
are subject to change without notice.

GROWATT NEW ENERGY TECHNOLOGY Co.,LTD A: No.28 Guangmming Road,