Professional Documents
Culture Documents
kWh/kWp 1,710.9
Production
Energy Consumption System Loss
50K
AC System: 0.3% Shading: 1.1%
Inverter: 1.5%
40K
Clipping: 0.0% Reflection: 3.1%
Wiring: 0.9%
30K
kWh
Mismatch: 3.2%
20K
Soiling: 2.0%
10K
Irradiance: 0.3%
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Irradiance Annual Global Horizontal Irradiance 2,054.2 - Weather Dataset TMY10km Gridmeteonorm/suny high resolution(meteonorm)
(kWh/m2)
Adjusted Global Horizontal Irradiance 2,054.2 0.0% Solar Angle Location Meteo Lat/Lng
Irradiance After Soiling 1,977.9 -2.0% Fixed Tilt -3.56 -0.08 3.0°C
Total Collector Irradiance 1,977.9 -0.0% Temperature Model Parameters Flush Mount -2.81 -0.05 0.0°C
Avg. Operating Ambient Temp 28.5°C TSM-DE21 640 (Trina Spec Sheet
Module
Solar) Characterization,PAN
Avg. Operating Cell Temp 40.7°C
TSM-DE21 640 (Trina Spec Sheet
Simulation Metrics Module
Solar) Characterization,PAN
Operating Hours 4,579
TSM-DE21 640 (Trina Spec Sheet
Module
Solved Hours 4,579 Solar) Characterization,PAN
Component Type Quantity Month GHI (kWh/m2) POA (kWh/m2) Shaded (kWh/m2) Nameplate (kWh) Grid (kWh)
240 mm2 (Aluminum) AC Home Runs 4 January 184.2 204.4 199.0 43,641.4 37,219.3
TSM-DE21 640 Modules 359 March 207.9 213.0 212.1 46,452.8 39,688.2
Design Render
Annual Production Report produced by Shanu Kannoth
Field Segments
Description Racking Orientation Tilt Azimuth Intrarow Spacing Frame Size Frames Modules Power
Field Segment 1 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 22 22 14.08 kW
Field Segment 2 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 40 40 25.60 kW
Field Segment 3 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW
Field Segment 4 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW
Field Segment 5 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 45 45 28.80 kW
Field Segment 6 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 40 40 25.60 kW
Field Segment 7 Fixed Tilt Portrait (Vertical) 10° 180° 6.0 ft 2x1 18 36 23.04 kW
Field Segment 8 Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW
Field Segment 8 (copy) Fixed Tilt Portrait (Vertical) 10° 180° 3.0 ft 1x1 24 24 15.36 kW
Field Segment 10 Fixed Tilt Landscape (Horizontal) 10° 180° 0.5 ft 1x1 80 80 51.20 kW
Shading Report produced by Shanu Kannoth
PDDP site 200kw PDDP Project, 5CG6+89C, Nedumbassery, Kerala 683546, India
Shading Heatmap
2,124, (100%)
1,964, (93%)
1,805, (85%)
1,646, (78%)
1,487, (70%)
Field Segment 1 10.0° 180.0° 34 21.8 kWp 2,093.0kWh/m2 37.3 MWh1 99.1% 99.4% 98.6%
Field Segment 3 10.0° 180.0° 33 21.1 kWp 2,092.8kWh/m2 36.2 MWh1 99.1% 99.4% 98.5%
Field Segment 4 10.0° 180.0° 30 19.2 kWp 2,092.9kWh/m2 32.9 MWh1 99.1% 99.4% 98.6%
Field Segment 5 10.0° 180.0° 36 23.0 kWp 2,094.0kWh/m2 39.5 MWh1 99.1% 99.5% 98.6%
Field Segment 10 10.0° 180.0° 36 23.0 kWp 2,079.8kWh/m2 39.3 MWh1 99.1% 98.8% 97.9%
Totals, weighted by kWp 313 200.3 kWp 2,089.0kWh/m2 342.7 MWh 99.1% 99.2% 98.4%
1
approximate, varies based on inverter performance
2
based on location Optimal POA Irradiance of 2,123.6kWh/m2 at 18.9° tilt and 175.0° azimuth
Description jan feb mar apr may jun jul aug sep oct nov dec
Field Segment 1 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%
Field Segment 1 (copy) 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%
Field Segment 3 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%
Field Segment 4 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 100% 100%
Field Segment 5 100% 99% 100% 100% 100% 99% 99% 100% 100% 99% 99% 99%
Field Segment 8 100% 99% 100% 100% 100% 99% 99% 100% 100% 99% 99% 98%
Field Segment 8 (copy) 100% 99% 100% 100% 100% 100% 99% 100% 100% 99% 99% 98%
Field Segment 7 95% 99% 100% 99% 99% 99% 99% 99% 99% 99% 98% 97%
Field Segment 6 100% 99% 100% 99% 99% 99% 99% 99% 99% 99% 98% 97%
Field Segment 10 96% 99% 100% 100% 99% 99% 99% 99% 99% 99% 98% 97%
Solar Access, weighted by kWp 98.7% 99.2% 99.6% 99.5% 99.5% 99.4% 99.3% 99.4% 99.4% 99.3% 99.0% 98.6%
AC Power (kWh) 32,905.0 32,517.0 34,490.0 29,908.5 27,467.3 22,442.9 23,322.9 26,570.1 28,257.1 27,070.9 28,099.7 29,601.0
40k
AC System: 0.3% Shading: 0.8%
Inverters: 1.5% Reflection: 3.1%
30k
Clipping: 0.0%
Wiring: 1.1%
kWh
Irradiance: 0.3%
10k
0
Temperature: 7.9%
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
PRODUCT: TSM-DEG21C.20
BIFACIAL DUAL GLASS MONOCRYSTALLINE MODULE POWER RANGE: 640-665W
High reliability
• Minimized micro-cracks with innovative non-destructive cutting
technology
• Ensured PID resistance through cell process and module material
control
• Resistant to harsh environments such as salt, ammonia, sand, high
temperature and high humidity areas
• Mechanical performance up to 5400 Pa positive load and 2400 Pa
negative load
90%
85.0%
Years 5 10 15 20 25 30
Se rial
16
num be r
14 800W/mS
12
Current (A)
600W/mS
10
8
4-Φ9×14 400W/mS
6
Installing Hole
4
200W/mS
A A 2
0 10 20 30 40 50
4-Φ7×10
Installing Hole Voltage(V)
2384
1400
700
400
600
1000W/mS
500
Power (W)
800W/mS
400
600W/mS
300
200 400W/mS
0 10 20 30 40 50
12-Drain Hole
Voltage(V)
B
16
14
12
Current (A)
Cell temp.=10℃
35
35
10
Cell temp.=25℃
8
Frame Frame Cell temp.=40℃
6
Cell temp.=55℃
4
Cell temp.=70℃
2
30 30
0 10 20 30 40 50
Peak Power Watts-PMAX (Wp)* 640 645 650 655 660 665 Solar Cells Monocrystalline
Short Circuit Current-ISC (A) 18.26 18.31 18.35 18.40 18.45 18.50 Back Glass 2.0 mm (0.08 inches), Heat Strengthened Glass (White Grid Glass)
Module Efficiency η m (%) 20.6 20.8 20.9 21.1 21.2 21.4 Frame 35mm(1.38 inches) Anodized Aluminium Alloy
J-Box IP 68 rated
STC: Irrdiance 1000W/m2, Cell Temperature 25ºC, Air Mass AM1.5. *Measuring tolerance: ±3%.
Electrical characteristics with different power bin (reference to 10% Irradiance ratio) Cables Photovoltaic Technology Cable 4.0mmS (0.006 inchesS),
Portrait: 280/280 mm(11.02/11.02 inches)
Total Equivalent power -PMAX (Wp) 685 690 696 701 706 712 Length can be customized
Maximum Power Voltage-VMPP (V) 37.3 37.5 37.7 37.9 38.1 38.3
Connector MC4 EVO2 / TS4*
Maximum Power Current-IMPP (A) 18.39 18.44 18.48 18.52 18.56 18.60 *Please refer to regional datasheet for specified connector.
Open Circuit Voltage-VOC (V) 45.1 45.3 45.5 45.7 45.9 46.1
TEMPERATURE RATINGS MAXIMUMRATINGS
Short Circuit Current-ISC (A) 19.54 19.59 19.63 19.69 19.74 19.79
NOCT(Nominal Operating Cell Temperature) 43°C (±2°C) Operational Temperature -40~+85ºC
Irradiance ratio (rear/front) 10% Temperature Coefficient of PMAX - 0.34%/°C Maximum System Voltage 1500V DC (IEC)
Power Bifaciality:70±5%. Temperature Coefficient of VOC - 0.25%/°C 1500V DC (UL)
ELECTRICAL DATA (NOCT) Temperature Coefficient of ISC 0.04%/°C Max Series Fuse Rating 35A
NOCT: Irradiance at 800W/mS, Ambient Temperature 20°C, Wind Speed 1m/s. (Please refer to product warranty for details)
CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.
© 2021 Trina Solar Co.,Ltd, All rights reserved, Specifications included in this datasheet are subject to change without notice.
Version number: TSM_EN_2021_A www.trinasolar.com
MAC 30~60KTL3-X LV
· 3 MPPTs
· Smart diagnosis
· High efficiency up to 98.8%
· Local WIFI connection
· OLED display and touch button
· AC&DC type II SPD
· Data storage up to 25 years
· DC side 2 in 1 connection enabled
www.ginverter.com
Longteng
Community,
Shiyan, Baoan
District,
Shenzhen,
Datasheet MAC 30KTL3-X LV MAC 40KTL3-X LV MAC 50KTL3-X LV P.R.China.MAC
T: + 60KTL3-X LV
86 755 2747
1900 F: + 86 755 2749 1460 E: info
Inputu data (DC)
Max. recommended PV
power(for module STC) 45000W 60000W 75000W 90000W
THDi <3%
AC grid connection type 3W+N+PE
Efficiency
Max. efficiency 98.7% 98.7% 98.7% 98.8%
European efficiency 98.4% 98.5% 98.5% 98.5%
MPPT efficiency 99.9%
Protection devices
DC reverse polarity protection Yes
DC switch Yes
AC/DC surge protection Type II / Type II
Insulation resistance monitoring Yes
AC short-circuit protection Yes
Ground fault monitoring Yes
Grid monitoring Yes
Anti-islanding protection Yes
Residual-current monitoring unit Yes
General data
Dimensions(W / H / D) 680/508/281mm
Weight 52kg
Operating temperature range –25°C ... +60°C
Altitude 4000m
DC connection H4/MC4(Optional)
Display OLED+LED/WIFI+APP
Interfaces: RS485 / USB
Yes/Yes /Optional/Optional/Optional
/WiFi/ GPRS / RF