You are on page 1of 1

PO Box 7257, Nelson 7042

90 St. Vincent Street, Nelson 7010


NEW ZEALAND
Phone: 64 3 548 4225
Fax: 64 3 546 8425
Email: enquiry@generation-global.com

Form 5 - Flammability Test Datasheet, Rev 25


FLAME TEST REPORT
ISSUED IN CONFORMANCE WITH NZCAA CERTIFICATE NUMBER MO48534
CUSTOMER: Generation Global, Date: 24/03/2023
90 St Vincent Street, Order:
Nelson
Job:
Test Plan No:
Description: Label material White Reg:
Quantity: 1 Sample Part No: DC-69075
Notes: Flame Test No: NAT-240323(d)

C. 14 CFR Part 25 Appendix F Part I(a)(1)(i) Amdt. 25-132, 60 second vertical Bunsen burner
D. 14 CFR Part 25 Appendix F Part I(a)(1)(ii) Amdt. 25-132, 12 second vertical Bunsen burner
E. 14 CFR Part 25 Appendix F Part I(a)(1)(iv) Amdt. 25-132, 15 second horizontal (2.5'/Min) Bunsen burner
F. 14 CFR Part 25 Appendix F Part I(a)(1)(v) Amdt. 25-132, 15 second horizontal (4'/Min) Bunsen burner

Test Procedure: D Fuel Type: Methane Gas Flame Temp: 866

VERTICAL 1 2 3 AVERAGE
Flame Time (sec) 13.0 12.0 13.0 12.7
Burn Length (mm) 100.0 107.0 112.0 106.3 C

Glow Time (sec) 0.0 0.0 0.0 0.0


Drip Ext. (sec) 0.0 0.0 0.0 0.0

TEST COMMENTS: PASSED

Certified by: Uros Radmanovic Auth by: NAI 1032 Date: 24/03/2023

The above signature indicates that the activity(s) recorded above have been carried out in accordance with the FAA Aircraft Materials Fire Test
Handbook DOT/FAA/AR-00/12 and Generation Global's Exposition procedures and the tested part meets the requirements.