You are on page 1of 2

RRU ApplNote002USv3_01 RRU ApplNote002USv3_01

Cable electric diagram


Cable
RRU - Remote Relay Unit
WTMD
5 pin
RRU
4 pin
connecting the Module of alarm signalling for CEIA Metal Detectors
9 pin 9-pin terminal terminal metal detector
D-sub female D-sub male board board
Vdc - 1 1 1 - Vdc N.C. - 4
through the
GND - 5 5 3 - GND N.O. - 2 communication Application note
BO OUT- 8 8 5 – BO IN C-1
port.

Cable
WTMD connecting the
RRU
6 pin 5 pin 4 pin metal detector
connector terminal terminal
board
directly to the
14 ~ board
13 +/~ 1 - Vdc N.C. - 4 control unit.
12 GND 3 - GND N.O. - 2
11 -/GND 5 – BO IN C-1
10 PP1
9 INIB
8 pin
connector
8 SERGND
7 BO
6 BUSY
5 SER OUT
4 SER IN
3 NA
2 NC
1C

CEIA USA Ltd


9155 DUTTON DRIVE • TWINSBURG OHIO
44087 USA Module RRU is a unit which can be connected to the CEIA Metal Detectors by
Tel. 330-405 3190 - Fax 330-405 3196
means of the top and bottom communication port, used for repeating the
detection alarms of the gate through a relay.
Web site: www.ceia.net

This document is property of CEIA which reserves all rights. Total or partial copy, modification and translation is forbidden. This document is property of CEIA which reserves all rights. Total or partial copy, modification and translation is forbidden
RRU ApplNote002USv3_01 RRU ApplNote002USv3_01

Description Connections
Kit composition
• Cable connecting the metal detector.

• RRU unit

• Application notes (this sheet)

84mm (3.3”) Output connector ATTENTION!


32mm (relay contacts) Do not use the lower
(1.3”) connection box!
23mm
(0.9”) ATTENTION!
Connect the wire inside
ø4mm (5/32”) the connection box!
Status LED

Technical features
• Directly powered by the metal detector.
• Connection to the Walk-Through Metal Detector via serial interface
• Connecting cable length (towards Metal Detector): 3m / 10ft or 10m / 33ft.
• Relay rating: 0.5A –30Vac/dc max.
STEP 1. Strip the end of the blue
wire connected to the RS 232
Operation socket.
WTMD status Output relay status LED status
Normal Pin C connected to pin N.C. OFF
Alarm Pin C connected to pin N.O. ON

Field of application
The RRU unit can be connected to all CEIA stand alone Metal Detectors, with the following
exceptions:
Model Hardware version Software version STEP 2. Insert the blue wire into
02PN20 All < 0151 the power supply connector (the
PMD2/EN column version < 7.0 All terminal to which a blue wire from
PMD2/EW column waterproof version < 6.0 All inside the antenna is already
MetCard All All connected).
Classic, SMD600, HI-PE (all models), 02PN7. All All

This document is property of CEIA which reserves all rights. Total or partial copy, modification and translation is forbidden. This document is property of CEIA which reserves all rights. Total or partial copy, modification and translation is forbidden