Professional Documents
Culture Documents
4
Zone: AGUA AMARGA CORRIENTE 12 Zone: AGUA AMARGA CORRIENTE 12 Zone: AGUA AMARGA CORRIENTE 12 Zone: AGUA AMARGA CORRIENTE 12
Ø: 6 in Ø: 6 in Ø: 6 in Ø: 6 in
Flow: 612.7 gpm Flow: 612.7 gpm Flow: 612.7 gpm Flow: 612.7 gpm
Re: 1.175E+06 Re: 1.175E+06 Re: 1.175E+06 Re: 1.175E+06
dP Total: -32.86 psi dP Total: 18.37 psi dP Total: -14.99 psi dP Total: 49.11 psi
P in Total: 99.88 psi g P in Total: 111.4 psi g P in Total: 75.48 psi g P in Total: 65.47 psi g
P out Total: 132.7 psi g P out Total: 93.06 psi g P out Total: 90.47 psi g P out Total: 16.36 psi g
3 14 6 8 2
Orifice Meter 3
Fixed dP Device 1 Control Valve 3 DA-01
Descarga DA-01 Ø: 2.454 in
Fixed dP: 16.36 psi Op: dP Total @ 25 psi Op: P Total @ 16.36 psi g
Op: Flow Rate @ 612.7 gpm Flow: 612.7 gpm
Flow: 612.7 gpm Flow: 612.7 gpm Flow: 612.7 gpm
Type: Flow in dP Total: 21.31 psi
dP Total: 16.36 psi dP Total: 25 psi P Total: 16.36 psi g
Flow: 612.7 gpm dP Static: 21.31 psi
P in Total: 93.06 psi g HL: 67.12 ft P Static: 16.03 psi g
P Total: 99.88 psi g HL: 57.21 ft
P out Total: 75.48 psi g P in Total: 90.47 psi g P Dynamic: 0.3292 psi
P Static: 99.55 psi g P in Total: 132.7 psi g
P out Total: 111.4 psi g P out Total: 65.47 psi g
P Dynamic: 0.3292 psi Flow Coefficient: 115.2 Cv
Beta: 0.426
Cd: 0.6018 Position: 23.03%
Y: -- % Deviation: 0%
PR: --
Dissipated Energy: 49748 kWh
Dissipated Energy Cost: $4974.83
% Deviation: 0%