This document contains three shear design problems from the chapter on reinforced concrete design. Problem 1 involves calculating the required spacing of vertical U-stirrups in a rectangular beam for different required shear strengths. Problem 2 calculates the required spacing of 10mm vertical U-stirrups in a beam supporting service dead and live load shear. Problem 3 determines the spacing of vertical stirrups near the support of a beam loaded with distributed service dead and live loads. The document provides the beam dimensions, material properties, and loads for each problem.
This document contains three shear design problems from the chapter on reinforced concrete design. Problem 1 involves calculating the required spacing of vertical U-stirrups in a rectangular beam for different required shear strengths. Problem 2 calculates the required spacing of 10mm vertical U-stirrups in a beam supporting service dead and live load shear. Problem 3 determines the spacing of vertical stirrups near the support of a beam loaded with distributed service dead and live loads. The document provides the beam dimensions, material properties, and loads for each problem.
This document contains three shear design problems from the chapter on reinforced concrete design. Problem 1 involves calculating the required spacing of vertical U-stirrups in a rectangular beam for different required shear strengths. Problem 2 calculates the required spacing of 10mm vertical U-stirrups in a beam supporting service dead and live load shear. Problem 3 determines the spacing of vertical stirrups near the support of a beam loaded with distributed service dead and live loads. The document provides the beam dimensions, material properties, and loads for each problem.
PROBLEM 1 A rectangular beam has the following properties: bw = 320 mm d = 570mm stirrups diameter, dt = 10mm fc’ = 24 Mpa fyt = 275 Mpa Determine the required spacing vertical U-stirrup when the required shear strength Vu is: a) 50 kN b) 90 kN c) 130 kN d) 290 kN e) 360 kN f) 570 kN Use the 2010 NSCP. PROBLEM 2 A rectangular beam has bw= 300mm and d = 580 mm. The beam is supported to service dead load shear of 126kN and live load shear of 138 kN at critical section. Use fc’ = 21 MPa and fyt = 275 Mpa. Determine the required spacing of 10mm vertical U-stirrups using NSCP 2015. PROBLEM 3 Determine the spacing of vertical stirrups near the left support of the beam loaded as shown in the figure. Given the following data: bw = 305 mm d = 590mm stirrups diameter, dt = 10mm fc’ = 25 Mpa fyt = 275 Mpa Service loads: wD = 30kN/m (including beam weight) and wL = 34kN/m L = 3m Use NSCP 2015. THANK YOU!