You are on page 1of 5

Replacement Reg.

code Registration code


Collection: APC GA15-22/2006
Tab: 15
INDUSTRIAL AIR DIVISION Edition: 00
9820 4599 02 april/2006

Stationary compressors: GA15-22/ 10 bar/ 50 Hz

AML: Principal data


PRELIMINARY GA15 GA18 GA22
10 10 10

Reference conditions

1. Absolute inlet pressure bar 1 1 1


2. Relative air humidity % 0 0 0
3. Air inlet temperature °C 20 20 20
4. Effective working pressure at outlet package bar 9.5 9.5 9.5
5. Motor shaft speed r/min 2940 2940 2940
6. Oil type Atlas Copco Roto-injectfluid
7. Setpoint thermostatic valve °C 40 40 40

Limitations for operations

1. Maximum effective working pressure at outlet package


- Pack bar 10.0 10.0 10.0
- Full Feature bar 9.75 9.75 9.75
2. Minimum effective working pressure at outlet package bar 4.0 4.0 4.0
3. Maximum allowable inlet temperature °C 46 46 46
4. Minimum ambient temperature °C 0 0 0

Performance data compressor (1)

1. Free Air Delivery (2)


at reference conditions l/s 36.3 43.5 51.7
at effective working pressure stated
- Pack at 10.0 bar / Full Feature at 9.75 bar l/s 36.2 43.4 51.6
- Pack / Full Feature 8.0 bar l/s 36.8 44.0 52.2
- Pack / Full Feature 6.0 bar l/s 37.2 44.4 52.6
- Pack / Full Feature 4.0 bar l/s 37.5 44.7 52.9

2. Power data

2.1. Performance data based on shaft input

2.1.1. Shaft power input (excl. fan)


at reference conditions
- Pack kW 16.7 20.3 23.7
- Full Feature kW 16.9 20.4 23.8
at effective working pressure stated
- Pack 10.0 bar kW 17.2 20.5 24.4
- Full Feature 9.75 bar kW 17.4 20.6 24.5

- Pack 8.0 bar kW 15.6 18.2 21.8


- Full Feature 8.0 bar kW 15.8 18.3 21.9

- Pack 6.0 bar kW 13.8 16.1 18.2


- Full Feature 6.0 bar kW 14.0 16.2 18.3

- Pack 4.0 bar kW 11.9 13.8 15.6


- Full Feature 4.0 bar kW 12.1 13.9 15.7

9820 4599 02 Ed. 00 Page 1/5


GA15 GA18 GA22
10 10 10

2.1.2. Specific Energy Requirement (excl. fan)


at reference conditions
- Pack J/l 461 466 459
- Full Feature J/l 466 468 461
at effective working pressure stated
- Pack 10.0 bar J/l 475 473 472
- Full Feature 9.75 bar J/l 480 476 474

- Pack 8.0 bar J/l 425 413 418


- Full Feature 8.0 bar J/l 431 415 420

- Pack 6.0 bar J/l 370 362 345


- Full Feature 6.0 bar J/l 375 365 348

- Pack 4.0 bar J/l 319 309 295


- Full Feature 4.0 bar J/l 324 311 297

2.1.3. Shaft input at no load (excl. fan) kW 3.5 3.9 4.9

2.1.4. Shaft input cooling fan kW 0.50 0.85 0.85

2.2. Performance based on packaged compressor (electrical) power input


Integrated Dryer Type (**) A6X A7X A7X

2.2.1. Power input


at reference conditions
- Pack kW 19.1 23.2 27.0
- Full Feature kW 20.1 24.2 28.0
at effective working pressure stated
- Pack 10.0 bar kW 19.6 23.5 27.7
- Full Feature 9.75 bar kW 20.6 24.5 28.7

- Pack 8.0 bar kW 17.9 20.9 24.9


- Full Feature 8.0 bar kW 18.9 21.9 25.9

- Pack 6.0 bar kW 15.8 18.6 20.9


- Full Feature 6.0 bar kW 16.8 19.6 21.9

- Pack 4.0 bar kW 13.8 16.1 18.1


- Full Feature 4.0 bar kW 14.8 17.1 19.1

2.2.2. Specific Energy Requirement (2)


at reference conditions
- Pack J/l 526 533 522
- Full Feature J/l 554 556 542
at effective working pressure stated
- Pack 10.0 bar J/l 541 541 537
- Full Feature 9.75 bar J/l 569 565 556

- Pack 8.0 bar J/l 486 475 477


- Full Feature 8.0 bar J/l 514 498 496

- Pack 6.0 bar J/l 425 419 397


- Full Feature 6.0 bar J/l 452 441 416

- Pack 4.0 bar J/l 368 360 342


- Full Feature 4.0 bar J/l 395 383 361

2.2.3. Power input at no load (2)


- Pack kW 4.8 5.6 6.8
- Full Feature kW 5.3 6.2 7.4

9820 4599 02 Ed. 00 Page 2/5


GA15 GA18 GA22
10 10 10

3. Compressed air temperature at outlet valve


- Pack a+ °C 8 8 8
- Full Feature a+ °C 0 0 0

4. Typical oil consumption l/100hrs 0.015 0.027 0.042


at reference conditions

5. Typical oil content of compressed air mg/m³ <2 <2 <2


at reference conditions

6. Mean sound pressure level (2) dB (A) 72 / 3 73 / 3 74 / 3

Design data (1)

Compressor
1. Number of compression stages 1 1 1
2. Male rotor speed r/min 3791 4583 5406

Motors
1. Drive motor efficiency at full load 90.2% 91.0% 91.0%
at no load 84.0% 85.0% 85.0%

Unit
1. Oil capacity (approx.) l 6.75 7.25 7.75
2. Blow off volume l 8.0 8.0 8.0
3. Time to reach 80% blow-off s 30.0 30.0 30.0
4. Cooling air flow referred to air inlet grating m³/s 1.1 1.15 1.2
5. Dimension of compressed air outlet valve (threaded) G 3/4 3/4 3/4
6. Condensate drainpipes
- Manual drain OD / ID mm/mm 6/4 6/4 6/4
- Automatic drain OD / ID mm/mm 8 / 5.5 8 / 5.5 8 / 5.5
- Manual drain air receiver G 1/4 1/4 1/4
7. Electrical cable passage M 50 50 50
8. Canopy dimensions
8.1 Floor mounted Pack
- Length mm 1285 1285 1285
- Width mm 680 680 680
- Height mm 922 922 922
8.2 Floor mounted FF
- Length mm 1770 1770 1770
- Width mm 680 680 680
- Height mm 932 932 932
8.3 Tank mounted Pack / FF
- Length mm 1853 1853 1853
- Width mm 680 680 680
- Height mm 1538 1538 1538
9. Net mass (approx.) - Workplace/ Workplace FF
9.1 Net mass (approx.) - Floor mounted
- Pack kg 375 395 410
- Full Feature kg 440 470 485
9.2 Net mass (approx.) - Tank mounted
- Pack kg 500 520 535
- Full Feature kg 565 595 610

9820 4599 02 Ed. 00 Page 3/5


GA15 GA18 GA22
10 10 10
10. Shipping dimensions - Workplace/ Workplace FF IFD
10.1 Floor mounted Pack
- Length m 1.39 1.39 1.39
- Width m 0.82 0.82 0.82
- Height m 1.17 1.17 1.17
10.2 Floor mounted FF
- Length m 1.88 1.88 1.88
- Width m 0.82 0.82 0.82
- Height m 1.17 1.17 1.17
10.3 Tank mounted Pack / FF
- Length m 1.99 1.99 1.99
- Width m 0.82 0.82 0.82
- Height m 1.8 1.8 1.8
11. Shipping volume (approx.) - Workplace/ Workplace FF IFD
11.1 Floor mounted Pack m³ 1.3 1.3 1.3
11.2 Floor mounted FF m³ 1.8 1.8 1.8
11.3 Tank mounted Pack / FF m³ 2.9 2.9 2.9
12. Shipping mass (approx.) - Workplace/ Workplace FF IFD
12.1. Europe
12.1.1. Floor mounted
- Pack kg 400 420 435
- Full Feature kg 470 500 515
12.1.2. Tank mounted
- Pack kg 535 555 570
- Full Feature kg 600 630 645
12.2. Overseas
12.2.1. Floor mounted
- Pack kg 445 465 480
- Full Feature kg 520 550 565
12.2.2. Tank mounted
- Pack kg 600 620 635
- Full Feature kg 665 695 710

9820 4599 02 Ed. 00 Page 4/5


GA15 GA18 GA22
10 10 10

Integrated Dryer (IFD) (*)

1. Integrated Dryer type A6X A7X A7X


2. Pressure dew point Workplace FF IFD at a = 20°C and Rh = 100% °C 5 5 5
3. Pressure drop over dryer bar 0.25 0.20 0.20
4. Total power consumption
at full load (a = 20°C and Rh = 100%, including fan) kW 0.7 0.8 0.8
at no load (a = 20°C and Rh = 0%, fan stopped) kW 0.5 0.6 0.6
5. Compressed air outlet temperature (a = 20°C, Rh = 100%) °C 20 20 20
6. Cooling air flow m³/min 14.0 18.2 18.2
7. Heat dissipated by cooling air (a = 20°C, Rh = 100%) kW 1.4 3.2 3.2
8. Refrigerant type R404a R404a R404a
Total amount kg 0.38 0.60 0.60

Note : (*) symbols


a: ambient temperature, Rh: relative humidity
(**) The data of 2.2.1 and 2.2.2 prevail for an Integrated Dryer at full load
(ambient a = 20°C and relative humidity Rh = 100%)

(1) Unless otherwise stated, at reference conditions


All values given with a tolerance according to specified
codes are guaranteed; all other values are to be considered typical.

(2) Data Code Tolerance


Free Air Delivery ISO 1217 ed. 1996 5%

Specific Energy Requirement ISO 1217 ed. 1996 6%

Power consumption at zero flow ISO 1217 ed. 1996 20%


Mean sound level ISO 2151

The international ISO 1217 ed. 1996 standard refers to following standards :
- ISO 5167 - British BS 1571 Part 2
- ISO 9300 - American ASME PTC9
- German DIN 1950

Ed.: 00

9820 4599 02 Ed. 00 Page 5/5

You might also like