You are on page 1of 7

APPENDIX ‘X’

DETAILS OF ELECTRICAL CONTRACTOR


Specialist Sub-Contractor

1. The tenderer is required to fulfil his Mechanical/Electrical Contractors for this tender, whose
particulars shall be given below.
2. The tenderer must ensure that the nominated Mechanical/Electrical Contractors are registered
with UPKJ under the correct Head and Class as stated in Clause A.1 of this specification, and that
at the time of tendering, no disciplinary action has been imposed on them by the Chief Electrical
Inspector. Failure to comply with the above will cause the whole tender to be rejected.
3. The tenderer shall note that once accepted, the Mechanical/Electrical Contractors shall not be
changed unless with the prior written approval of the Superintending Officer.
4. (a) Name of Mechanical/Electrical Contractor : …………………………………………

(b) Address: ………………………………………………………………..…

(c) Registration with UPKJ (Head/Class) : …………………………………..


(enclose certified copy of UPKJ registration)

(d) Tel. :……………………….. Fax.: ………………………………………

Signature And Sealed Mechanical/Electrical Contractor : .................................................................................

Date : ..................................................

SCHEDULE ‘A’
SUMMARY OF WORKS

PROPOSED CONSTRUCTION OF NEW PONTOON INTAKE AND JETTY AT NANGA SEKUAU WATER
TREATMENT PLANT, SIBU DIVISION, SARAWAK

The amount entered shall include supply and delivery, erection and installation, testing and commissioning, and all duties and
taxes necessary to complete the whole installation as per drawing and specification. Claims due to omissions of item shall not be
entertained. Remarks: Source of electricity supply from Sesco and Genset.
Unit rate Amount
Item Scope of works Qty (RM) (RM)

General and Preliminaries Lump


(including insurances, transportation,modified base for pump, Sum
cabling, piping if necessary & etc. )

A GENSET ROOM

Supply and install SSB-wall mounted; for details (see drawing


1 1 lot
no: SWA/02/05

2 35mm sq PVC/ELPE/PVC Cable from MSB to New SSB Panel 3 Meter

3 16mm sq armoured PVC/SWA/PVC cable from SSB Panel to 20 Meter


2 unit new Auto-Trans Starter.

25mm sq armoured PVC/SWA/PVC cable from Auto-Trans


4 Starter to termination box at Pontoon. The cable shall be laid 260 Meter
in proper cable tray.

Supply , deliver, installation, c/w testing and


B commissioning ( New Pontoon)

Submersible Pump : 11KW/ 3phase, 50hz, 960 L/Min , 27


1 meter head c/w, including bracket, cable, fitting, litereture, all 2 unit
auxiliary equipments connection cabling to termination box .
Supply and Install weather proof termination panel box c/w
2 all the associated electrical components for the raw water 2 nos
pump.

Supply and Install 2 unit auto-trans starter 11KW (install at


3 Genset room)c/w ammeter, voltmeter, magnetic contactor, 2 nos
and all necessary accessories

Supply and install navigation light & safety reflective board at


4 4 unit
side of pontoon and jetty for river navigation guide.

Control & Treated Water Pump Room


C

Supply and install SSB-wall mounted; for details (see drawing


1 1 lot
no: SWA/02/09

4x6 mm sq PVC/SWA/PVC cable from SSB to Push Button


2 20 Meter
ON/OFF metering pump.

Supply and install control box (push button ON/OFF)c/w all


3 2 nos
necessary accessories

4x6 mm PVC/SWA/PVC from (push button ON/OFF) to


4 10 Meter
Dosing Pump.( Alum/Soda)

5 16mm sq armoured PVC/SWA/PVC cable from SSB-Panel to 10 Meter


Auto-Trans stater for existing 22KW treated water pump No.3

6 Supply and install 16mm sq armoured PVC/SWA/PVC cable 10 Meter


from auto-trans starter to treated pump no.3

Renovation & Improvement Works for Existing Treated


D Water Pumpset

Install existing 1 unit 30HP Treated Water Pump set at the


clear water well reservoir, make foundation and concrete
1 1 lot
plinth, footvalve 4” suction inlet pipe and 3'' outlet pipe for
supply water to Stapang High Level Tank.

Installation and rectify of 1 unit existing auto-trans starter


2 22KW/30HP for treated water pump set no.3 1 lot

3 Install existing metering pump for alum and soda 1 lot

Supply and install 1 no 1 ton electrical powered chain hoist


(up&down) c/w cable connection and to make support for 6
4 1 lot
feet x 6 feet metal roofing at the existing Raw Water Intake
Sump.

Rectify and reconnection existing circuit for lighting, socket,


5 c/w 2 unit auto-trans starter for pump No.1&2 and etc; form 1 lot
old SSB connection to new SSB Panel ( Control room).

Rectify and reconnection existing 2 unit auto-trans starter for


6 raw water pump set (old intake) and etc; to new SSB Panel 1 lot
( Genset room)

7 Testing & Commissioning 1 lot

Miscellaneous not include in the item above but are deemed


to be necessary to complete the whole installation (state
detailed if applicable)
8 1 lot
1...............................................................................

2................................................................................

Sub - Total Carried Forward To Summary Of Tender

Signature and Chop of Contractor: ..................................................................................

Name of Firm: ..................................................................................................................

Address :............................................................................................................................

............................................................................................................................

Telephone No. : ........................................... Date : .................................


SCHEDULE ‘B’

PROPOSED CONSTRUCTION OF NEW PONTOON INTAKE AND JETTY AT NANGA SEKUAU WATER
TREATMENT PLANT, SIBU DIVISION, SARAWAK

Schedule of Technical Details

To be completed by all tenderers. The Tender not accompanied by


the properly completed Schedule shall be rejected

Pump
Manufacturer
Country of Manufacture
Brand/Model
Suction Size (mm)
Delivery Size (mm)
Impeller Size (mm)
Speed (RPM)
Discharge (l/s)
Total Head (m)
Efficiency
Shaft Power
Casing Material
Impeller Material
Shaft Material
Mechanical Seal Material

Schedule of Technical Details

To be completed by all tenderers. The Tender not accompanied by


the properly completed Schedule shall be rejected

Motor
Manufacturer
Country of Manufacture
Brand/Model
Type
Type of Enclosure IP
Rated Power kW
Full Load Speed RPM
Voltage/Cycle/Phase
Full Load Current
Insulation Class
Efficiency At :
100%
75%
50%
Power Factor at :
100%
75%
50%
Bearing Type DE/NDE
Cooling Jacket Provided
Pump Control Panel
Manufacture of Switch Board
MCCB Manufacturer
Type
Short Circuit Capacity Kit
TPN Rating (A)
Auto Transformer Manufacturer
Power Rating (kW)
Protection Class
Type of Motor Projection

SCHEDULE ‘C’

TECHNICAL DATA AND UNIT RATE SCHEDULE

Failure to complete this schedule may render the tenderer to be rejected. Once this schedule is
accepted, the contractor shall not change any item. Its acceptance does not relieve the Contractor of
responsibility to ensure that equipment concerned meets the characteristic and performance specified.
The unit rate shall refer to the brand of item and model offered and shall fairly represent its market
value. Otherwise the Contractor may require adjusting the rate. Unit rate shall include delivery,
installation and testing.

ELECTRICAL INSTALLATION:

1. Sub Switchboard – Wall – mounted SSB


a) Manufacturer :…………………………………
Address :…………………………………
CEI Lisence :…………………………………

2. Auto Transformer Starter Panel


a) Manufacturer :…………………………………
Address :…………………………………
CEI Lisence :…………………………………

3. Distribution Boards Make/Model Unit Rate (RM)

a) MCCB ................................. ................................

b) RCCB …………………….. …………………….

c) ELR ................................. ................................

d) MCB …………………….. …………………….

e) D.O.L Starter …………………….. …………………….


4. Underground cable & Submain Cable Make/Model Unit Rate (RM)/M

a) 4C 6mm2 PVC/SWA/PVC ..................................... ..............................

b) 4C 16mm2 PVC/SWA/PVC ..................................... ...............................

c) 4C 25mm2 PVC/SWA/PVC ..................................... ..............................

d) 4C 35mm2 PVC/SWA/PVC ..................................... ...............................

SCHEDULE ‘D’

LIST OF EQUIPMENT / CATALOGUES

The original catalogues for the following equipment must be attached with the Tender Document:

1. Main Switchboard, Sub-Switchboard, Distribution Board & accessories

2. Electronic Surge Protection System Installation

You might also like