You are on page 1of 1

8 7 6 5 4 3 2 1

LEGEND
Proposed
Existing

D D

Equalization Blower Aeration Blower


1Duty+1Standby Return Sludge 1Duty+1Standby
Acid Caustic Coagulant From 2nd Clarifier
105m3/h Flocculant 700m3/h
FIT

FIT

Final Discharge
Dissolved Oxygen
Intake Pump pHIT AIT

Basket Screen
1Duty+1Standby

70m3/h Self Cleaning Filter


SCF Pump
Raw Wastewater 1Duty+1Standby
Break Tank
12m3 70m3/h
Dissolved Air Flotation
C 70m3/h C
Equalization Tank Wastewater Pump pH Adjustment Tank Coagulation Tank DAF Transfer Pump Aeration Tank Secondary Clarifier

180 m3 1Duty+1Standby 11.7m3 11.7m3 1Duty+1Standby 450m3 70m3h


*Including utilization of existing Aeration Tank
70m3/h 70m3/h Sludge Holding Tank
Equalization Tank
Existing Intake Sump Recirculation Pump Return & Waste Sludge Pump
1Duty 1Duty+1Standby
Waste Sludge
35m3/h From Aeration Tank 18m3/h
Air Compressor
1Duty
DAF Sludge Pump
9.5m3/h
1Duty

5m3/h

Sludge Holding Tank


pH Adjustment Tank pH Adjustment Tank Coagulation Tank DAF 10m3

Caustic Dosing Pump Acid Dosing Pump Coagulant Dosing Pump Flocculant Dosing Pump
1Duty 1Duty 1Duty 1Duty
Dewatered Sludge
20Lh 20Lh 65Lh 210Lh

Coagulant Tank Filter Press


Caustic Tank Acid Tank Flocculant Tank
B B
500L/cycle
1m3 1m3 2m3 2m 3
Filter Press Feed Pump
1Duty
Dewatered Sludge
5m3/h

Existing Filter Press


595L/cycle

A A

8 7 6 5 4 3 2 1

You might also like