You are on page 1of 12

ENVILAB SDN BHD

Our ref KN(IECS)/TCP/04102023

4th October 2023

INDUSTRIAL EFFLUENT
CHARACTERIZATION STUDY

FOR

KONTENA NASIONAL BHD

NO 249, JALAN TEMBAGA 1,


KAWASAN PERINDUSTRIAN PASIR
GUDANG,
81750 PASIR GUDANG,
JOHOR

On

5th – 7th SEPTEMBER 2023


ENVILAB SDN BHD

Our ref KN(IECS)/TCP/04102023

4th October 2023

INDUSTRIAL EFFLUENT CHARACTERIZATION STUDY

FOR

KONTENA NASIONAL BHD


******************************************************************************
SECTION I – GENERAL PROCEDURE

1.0 INTRODUCTION

Upon requested by Kontena Nasional Bhd, an industrial effluent characterization study was
conducted on 5th until 7th September 2023, of which raw effluent samples were collected from
the sampling location. The study was conducted over a period of three (3) days during the
factory operation hours as the samples were collected as per client’s specified time and
sampling points. Samples were collected without any dilution from other sources of water.

Effluent samples were collected and analyse on parameters as specified under the
Environmental Quality (Industrial Effluent) Regulations 2009. In-situ measurement was
carried out on pH, temperature (ºC) and flowrate (m3/hr). The daily samples were preserved,
composite and tested for DOE listed parameters.

2.0 SAMPLING INFORMATION

2.1 Sampling Site


No 249, Jalan Tembaga 1, Kawasan Perindustrian Pasir Gudang, 81750 Pasir
Gudang, Johor

2.2 Sampling Point


i) Raw effluent

2.3 Sampling Date


5th – 7th September 2023

2.4 Sampling Representative


Envilab Sdn Bhd : Tan Cher Pin

Kontena Nasional Bhd : Shafiq

1
ENVILAB SDN BHD

3.0 ANALYSIS INFORMATION

3.1 In-Situ Measurements


In-situ measurement was carried out on the following parameters:
i) pH
ii) Temperature (°C)
iii) Flowrate (m3/hr)

3.2 Individual Samples


The samples were composited and tested on parameters listed under the Fifth and
Seventh Schedule of the Environmental Quality Act 1974, Environmental Quality
(Industrial Effluent) Regulations 2009, Standard B.

3.3 Testing Procedure


Testing procedures were as described in APHA 21st Edition methods.

4.0 DEFINITION OF THE PARAMETERS

4.1 Biochemical Oxygen Demand


BOD is the most commonly used parameter to define the strength (or concentration) of
an organic industrial waste.

BOD is by definition of quantity of oxygen utilised by a mixed population of micro-


organisms.

4.2 Chemical Oxygen Demand


COD is widely used to characterise the organic strength of wastewater and pollution of
natural waters.

The test measures the amount of oxygen required for chemical oxidation of organic
matter in the sample to carbon dioxide and water.

4.3 Solids
Suspended and dissolved solids, both organic and inert, are common tests polluted
waters.

4.4 pH
The acidic nature of water is related to the concentration of hydrogen ions in water
solution by used of the symbol pH, where:
1
pH = log
H+
The pH scale, ranging from 0 to 14, is acid from 0 to 7 and base from 7 - 14.

2
ENVILAB SDN BHD

5.0 SAMPLES PRESERVATION

Under DOE 31 parameters there are twelve types of sample handling and preservations
mainly for the BOD and Chromium VI, COD, Metals, Oil and Grease, Phenol, Cyanide,
Sulfide, Boron, Chlorine Formaldehyde, Fluoride, Colour and Ammoniacal Nitrogen.
The methods of preservation are summarized as follows:

No. of Parameter Volume (ml) Method of preservation


bottle
Bottle 1 Metals, Silver, 1000 Filter immediately, add
(Plastic) Aluminium, Barium, HNO3 to pH < 2
Selenium, General
Bottle 2 BOD, 1000 Refrigerate
(Plastic) Chromium VI, NO3-, P
Bottle 3 COD, 1000 Add H2SO4,
(Plastic) Phenols pH < 2, Refrigerate
Bottle 4 Oil & Grease 1000 Add H2SO4,
(Glass) pH < 2, Refrigerate
Bottle 5 Cyanide 500 Add NaOH to pH > 12,
(Plastic) Refrigerate in dark
Bottle 6 Sulphide 500 Refrigerate, add 4 drops
(Plastic) Zinc acetate/100ml
Add NaOH to pH > 9
Bottle 7 Boron 500 Not required
(Plastic)
Bottle 8 Chlorine 500 Analyze immediately
(Plastic)
Bottle 9 Formaldehyde 500 Not required
(Plastic)
Bottle 10 Fluoride 300 Not required
(Plastic)
Bottle 11 Colour 500 Refrigerate
(Plastic)
Bottle 12 Ammoniacal Nitrogen 500 Add pH < 2 with H2SO4,
(Plastic) refrigerate

3
ENVILAB SDN BHD

SECTION II – ANALYSIS

1.0 IN-SITU MEASUREMENT


1.1 Final Discharge (DAY 1-3)
1.1.1 Parameter: pH

Day 1 Day 2 Day 3


Time
(5/9//2023) (6/9/2023) (7/9/2023)
0900 10.1 4.2 10.0
1000 9.6 4.2 9.8
1100 9.3 4.2 9.5
1200 9.2 7.0 9.4
1300 8.6 6.9 9.8
1400 7.9 9.8 9.9
1500 6.4 10.3 9.9
1600 5.8 10.5 9.9
Average 8.3 7.1 9.7

pH vs Time For Raw Effluent Point


12

10

8
Day 1
pH

6 Day 2

4 Day 3
pH Min
2
pH Max

0
9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM

Time

4
ENVILAB SDN BHD

1.1.2 Parameter: Temperature (°C)

Day 1 Day 2 Day 3


Time
(5/9//2023) (6/9/2023) (7/9/2023)
0900 38.1 31.3 34.3
1000 37.3 31.3 34.5
1100 36.1 31.5 38.6
1200 35.8 31.6 38.5
1300 33.6 32.0 40.1
1400 32.5 31.8 44.3
1500 32.9 32.2 41.0
1600 32.8 38.6 41.1
Average 34.9 32.5 39.1

50 Temperature vs Time For Raw Effluent


Temperature (°C)

45
40
Day 1
35
Day 2
30
Day 3
25
T Max
20
9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM
Time

5
ENVILAB SDN BHD

1.1.3 Parameter: Flowrate (m3/hr)

Day 1 Day 2 Day 3


Time
(5/9//2023) (6/9/2023) (7/9/2023)
0900 0.9 2.0 0.5
1000 1.5 2.0 1.0
1100 1.5 2.0 1.0
1200 1.5 1.0 0.5
1300 0.5 0.5 0.5
1400 0.5 0.5 2.0
1500 2.0 2.0 2.0
1600 2.0 2.0 2.0
Average 1.3 1.5 1.1
Peak 2.0 2.0 2.0

Flowrate vs Time For Raw Effluent


2.5

2
Flowrate (m3/hr)

1.5

Day 1

1 Day 2
Day 3

0.5

0
9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM
Time

6
ENVILAB SDN BHD

2.0 LABORATORY ANALYSIS OF INDUSTRIAL EFFLUENT SAMPLES


2.1 Industrial Effluent Characterization Study Composited Final Discharge Sample.
Laboratory analysis is based on the DOE Standard B Limits. All parameters are
expressed in mg/L, except for pH and temperature.

DOE Day 1 Day 2 Day 3


Parameter
Standard B 18 Oct 2022 10 Oct 2022 20 Oct 2022
Temperature, 0 C In Situ < 40 34.9 32.5 39.1
pH In Situ 5.5 – 9.0 8.3 7.1 9.7
Biological Oxygen Demand
≤ 50 493 658 640
(BOD5), 20oC
Chemical Oxygen Demand
≤ 200 1480 1980 1980
(COD)
Suspended Solids (SS) ≤100 394 224 344
Mercury (as Hg) ≤ 0.05 ND<0.001 ND <0.001 ND <0.001
Cadmium (as Cd) ≤ 0.02 ND<0.01 ND <0.01 ND <0.01
Chromium (as Cr VI) ≤ 0.05 ND <0.05 ND <0.05 ND <0.05
Chromium (as Cr III) ≤ 1.0 ND <0.05 ND <0.05 ND <0.05
Arsenic (as As) ≤ 0.10 ND <0.001 ND <0.001 ND <0.001
Cyanide (as CN) ≤ 0.10 ND <0.01 ND <0.01 ND <0.01
Lead (as Pb) ≤ 0.50 ND <0.10 ND <0.10 ND <0.10
Copper (as Cu) ≤ 1.0 ND <0.01 ND <0.01 ND <0.01
Manganese (as Mn) ≤ 1.0 ND <0.01 0.1 ND <0.01
Nickel (as Ni) ≤ 1.0 ND <0.05 ND <0.05 ND <0.05
Tin (as Sn) ≤ 1.0 ND <0.001 ND <0.001 ND <0.001
Zinc (as Zn) ≤ 2.0 ND <0.01 ND <0.01 ND <0.01
Boron (as B) ≤ 4.0 ND <0.10 ND <0.10 ND <0.10
Iron (as Fe) ≤ 5.0 1.30 2.58 1.80
Silver ≤ 1.0 ND <0.05 ND <0.05 ND <0.05
Aluminium ≤ 15 22.6 85.2 19.8
Selenium ≤ 0.5 ND <0.001 ND <0.001 ND <0.001
Barium ≤ 2.0 ND <1.0 0.7 ND <1.0
Fluoride ≤ 5.0 ND <0.02 2.9 ND <0.02
Formaldehyde ≤ 2.0 ND <0.1 ND <0.1 ND <0.1
Phenol ≤ 1.0 ND <0.10 ND <0.10 ND <0.10
Free Chlorine ≤ 2.0 ND <1.0 ND <1.0 ND <1.0
Sulphide ≤ 0.50 ND <0.10 ND <0.10 ND <0.10
Oil & Grease ≤ 10 100 8 126
Ammoniacal Nitrogen ≤ 20 ND <0.1 ND <0.1 ND <0.1
Colour, ADMI * ≤ 200 38 182 244

*ADMI – American Dye Manufacturers Institute

7
ENVILAB SDN BHD

SECTION III - DISCUSSION & CONCLUSION

1) Raw Effluent
Based on the chemical analysis results and in-situ measurement obtained from the three (3) days
Industrial Effluent Characterization Study (IECS), the following parameters were found to be non-
compliance with the government stipulated Standard B limits under the Fifth Schedule and Seventh
Schedule of the Environmental Quality Act 1974, Environmental Quality (Industrial Effluent)
Regulations 2009.

a) pH
Values obtained for Day 3 (9.7) before treatment has exceeded the DOE Standard B treated effluent
discharge limit which is in the range of pH 5.5 – 9.0

b) BOD (Biological Oxygen Demand)


Values obtained for Day 1 (493), Day 2 (658) & Day 3 (640) before treatment have exceeded the DOE
Standard B treated effluent discharge limit which is ≤ 50

c) COD (Chemical Oxygen Demand)


Values obtained for Day 1 (1480), Day 2 (1980) & Day 3 (1980) before treatment have exceeded the
DOE Standard B treated effluent discharge limit which is ≤ 200

d) SS (Suspended Solid)
Values obtained for Day 1 (394), Day 2 (224) & Day 3 (344) before treatment have exceeded the DOE
Standard B treated effluent discharge limit which is ≤ 100

e) Al (Aluminium)
Values obtained for Day 1 (22.6), Day 2 (85.2) & Day 3 (19.8) before treatment have exceeded the
DOE Standard B treated effluent discharge limit which is ≤ 15

f) Oil & Grease


Values obtained for Day 1 (100) & Day 3 (126) before treatment have exceeded the DOE Standard B
treated effluent discharge limit which is ≤ 10

g) Colour (ADMI)
Values obtained for Day 3 (244) before treatment has exceeded the DOE Standard B treated effluent
discharge limit which is ≤ 200

8
ENVILAB SDN BHD

Certificate of analysis for composited samples

APPENDIX I

9
ENVILAB SDN BHD

Photograph of the sampling

APPENDIX II

11
ENVILAB SDN BHD

SAMPLING PHOTO

Figure 2: Raw Effluent Samples for Day 1

Figure 1: Sampling Point for Raw effluent

Figure 3: Raw Effluent Samples for Day 2


Figure 4: Raw Effluent Samples for Day 3

12

You might also like