You are on page 1of 4

Manufacturer’s review of data from APT

1 APT key data


APT case number 40856
APT sign off (date) 2023-11-24
APT data received 2023-11-27
Vessel name ROSA DINI
IMO number 9240718
MMSI number 525119081
VDR Model DM400 – VDR
VDR serial number A06971-002000
Technicians ID # 12776
Technicians name heru setyawan
Technicians company Jason Electronics PTE Ltd
Technicians certificate number D127270-2 Valid Yes

2 Data items to be recorded


Data item VDR (2014) VDR S-VDR Note
MSC.333(90) A.861(20) MSC.163(78)
Date and time YES
Ship’s position YES
Speed YES
Heading YES
Bridge audio YES
Communication audio YES
Radar data YES
ECDIS NO
AIS YES
Echo sounder YES
Rudder order and response YES
Engine order and response YES
Hull opening (doors) status NO
Watertight and fire door status NO
BNWAS YES
Main Alarms / Bridge alert YES
management
Electronic logbook NO
Inclinometer NO
Acceleration and hull stresses NO
Wind speed and direction NO
Optional input.
For VDR (MSC.333(90): Inclinometer with an electronic output must be recorded if fitted. Electronic logbook must be recorded if fitted.
For VDR (A.861(20)): Recording of AIS is optional.
For all VDR: Acceleration and hull stresses must be recorded where ship is fitted with IMO mandated monitoring equipment. Wind speed
and direction must be recorded where ship is fitted with suitable sensor.
For S-VDR: Must be recorded if sensor data is available in accordance with IEC61162).

Radar data may be substituted by AIS if the radar for technical reasons cannot be connected to an S-VDR.

Page 1 of 4
3 Check of report from manual check
Passed

4 Check of verification report


4.1 APT
4.1.1 Rudder
The data from the equipment is unreadable. The output of the equipment, cabling and
communication parameters on the VDR configuration must be checked

4.1.2 Fixed capsule orange foil


The capsule orange foil has faded/been damaged. Use P/N: 3302200 Orange foil, replacement for
Danelec MK3 capsule.
This issue was also found during the last APT. All issues described in the latest APT review report
must be corrected.

4.1.3 APT Tool


Latest APT tool version 2.13 should be used. New APT tool can be downloaded from the partner
site. (This is not accord to the terms set in Danelec Service Policy Commitment)

4.1.4 VDR status


The auxiliary fan in the right side of the DPU is switched on regularly. This indicates that the
primary fan located in the lid of the DPU is defective or alternatively that the environmental
temperature where the DAU is installed is high. The primary fan located in the lid of the DPU must
be checked.

Page 2 of 4
4.2 VDR Explorer
4.2.1 AMS
The AMS data should be decoded with suitable objects. Refer to equipment documentation on the
ship for info, otherwise inform owner/crew to seek manufacturers for relevant NMEA decoding list
to interpret the data.

Page 3 of 4
5 Danelec Marine’s acceptance
A major issue and a number of minor issues (which must be fixed latest at the next APT) were
discovered during the review.

Danelec Marine has reviewed the APT data and will issue a certificate when issue described in
section 4.1.1 is resolved.

Danelec Marine A/S


Copenhagen
30. November 2023

Page 4 of 4