You are on page 1of 2

AA Instrument/Software/PC/Printer Compatibility Chart

- Current Status -

Instrument Current PCs tested OP Systems tested Printers tested PCs/Printers Special Items
Software and supported and supported and supported tested not
Release (bi-directional cable compatible
[IEEE 1284] required)
AAnalyst AA WinLab Dell Optiplex GXi up to 166 MHz Windows 95 HP DeskJet 692C All GDI printers
100/300 rev. 3.20 Dell Optiplex GXa up to 233 MHz Windows NT 4.0 (SP3) HP DeskJet 694C HP DeskJet 970
Dell Optiplex GX1 up to 500 MHz HP DeskJet 695C
AAnalyst AA WinLab Dell Optiplex GXi up to 233 MHz Windows 95 HP DeskJet 810C Dell Optiplex Gn PCI-GPIB card is used, instructions
600/700/800 rev. 3.90 Dell Optiplex GXa up to 266 MHz (see SDB AAWL021C.STB) HP DeskJet 870Cxi HP LaserJet 5L for card/driver installation must be
Dell Optiplex GX1 up to 500 MHz Windows NT 4.0 (SP3) HP DeskJet 890Cxi HP LaserJet 6L followed exactly (see SDB
HP DeskJet 895Cxi All GDI printers 4200003B.STB).
HP LaserJet 6P HP DeskJet 970
SIMAA 6000 AA WinLab Dell Optiplex GXi up to 233 MHz Windows 3.11 HP LaserJet 1100 Dell Optiplex Gn PCs >200 MHz only run reliably if
rev. 2.50 Dell Optiplex GXa up to 266 MHz Windows 95 (Rel. A & B) HP LaserJet 4000 HP LaserJet 5L 32-bit GPIB Drivers are installed.
Dell Optiplex GX1 up to 500 MHz Windows NT 4.0 (SP3) HP LaserJet 6L Special install procedure for 32-bit
All GDI printers and NT GPIB drivers!).
HP DeskJet 970 (see SDBs AAWL017A.STB,
AAWL017B.STB, SIMA041A.STB
FIMS 100/400 AA WinLab Dell Optiplex GXi up to 233 MHz Windows 3.11 Dell Optiplex Gn PCs >200 MHz only run reliably if
rev. 2.50 Dell Optiplex GXa up to 266 MHz Windows 95 (Rel. A & B) HP LaserJet 5L 32-bit GPIB Drivers are installed.
Dell Optiplex GX1 up to 500 MHz Windows NT 4.0 (SP3) HP LaserJet 6L Special install procedure for 32-bit
All GDI printers and NT GPIB drivers!
HP DeskJet 970 (see SDBs AAWL017A.STB,
AAWL017B.STB, SIMA041A.STB
Multiwave N/A N/A N/A HP LaserJet 4
HP DeskJet 850C
Epson SQ 2500
Epson LQ 1050
Epson LQ 850
Epson EX 800
Mannesmann Tally

Windows 98 operating system is not supported

prepared by U. Trommer, AA Business Unit Last Updated: 30. March 2000 Page 1 of 2
AA Instrument/Accessories Compatibility Chart
- Current Status -

Accessories
HGA-850 FIAS 100/400 Autoprep-50 AS for FIMS/FIAS Stand – Alone Flame Autosampler MHS-10 USS-800
Spectrometer (FIMS used as AS-90 AS-90plus AS-90A
FIAS) (B050-8540) (B314-0291) (B314-0290)
AS-91 AS-93plus
(B050-9080) (B314-0330)
AAnalyst Yes, Yes, Yes, Not direct AS-90plus: Yes Not compatible Yes Not compatible
100/300 AA Cell holder AA WinLab compatible, Cell holder
WinLab B300-0350 or rev. 2.61 or FIMS/FIAS needed AS-93plus: Yes, B300-0350
rev 3.20 heated quartz cell higher and for full required
required assembly Windows compatibility AA
B010-2953 required 95/NT required WinLab 3.00 or
higher required
AAnalyst N/A Yes, AA 700/800: Not direct AS-90plus: Yes Yes, Yes Yes,
600/700/800 AA 700/800: Yes, compatible, AA WinLab rev. Cell holder AA WinLab rev.
heated quartz cell AA WinLab FIMS/FIAS needed AS-93plus: Yes, 3.71 or higher B300-0350 3.71 or higher
assembly rev. 3.71 or for full required required required
B312-0390 required higher required compatibility AA
AA 600: WinLab 3.90
heated quartz cell AA 600: required
assembly No
B300-1600 required
SIMAA 6000 N/A Yes, N/A Not direct N/A N/A Not Not compatible
heated quartz cell compatible, compatible
assembly FIMS/FIAS needed
B300-1600 required
FIMS 100/400 N/A N/A N/A Yes AS-90plus: No Not compatible N/A N/A

AS-93plus: No

prepared by U. Trommer, AA Business Unit Last Updated: 30. March 2000 Page 2 of 2