You are on page 1of 74

TCON ERROR CODES & DESCRIPTIONS

Revision 2.54 - Firmware Version 2.04


Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

The TCON is protecting the transmission Apply the service brakes, and allow the retarder Check the retarder temperature and the
Analog Input function: Transmission retarder and does not allow that the retarder / transmission oil to cool down. Once the The measured value of the retarder retarder temperature sensor.
temperature : Data Valid but Above Normal Operational temperature exceeds its limit. The retarder temperature is below the critical temperature, temperature is above the critical If operating in dirty environment clean out
84.00 120 0 Amber warning Flashing Range - Most Severe function will be gradually to fully disabled resume normal operation. temperature. radiator fins to allow maximum air flow.

- Check the wiring between the TCON and the


device connected to this analog input.
The retarder temperature value will be - Check installation and operation of the device
Analog Input function: Transmission retarder replaced by an appropriate default value. connected.
temperature : Voltage Above Normal, or Shorted To High The TCON will disable the retarder The input most likely has a loose connection - refer to the other reported errors to identify
84.03 120 3 Amber warning Flashing Source functionality. Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.
- Check the tranmission oil level
- Check the wiring between the TCON and the
Input function: Transmission oil level detection: Data oil level sensor
Valid but Above Normal Operational Range - Most The TCON is detected that the transmission Check service manual how to drain oil from the - Check installation and operation of the oil level
85.00 3027 0 Amber warning Flashing Severe oil level is too high. transmission. Oil level in the transmission is too high sensor
- Check the tranmission oil level
- Check the wiring between the TCON and the
oil level sensor
Input function: Transmission oil level detection: Data The TCON is detected that the transmission Check service manual how to add oil to the - Check installation and operation of the oil level
85.01 3027 1 Amber warning Flashing Valid but Below Normal Operational Range - Most Severe oil level is too low. transmission. Oil level in the transmission is too low sensor
- Check the wiring between the TCON and the
oil level sensor
Input function: Transmission oil level detection: Data The TCON has detected that the - Check installation and operation of the oil level
85.02 3027 2 Amber warning Flashing Erratic, Intermittent, or Incorrect transmission oil level sensor are not in line. Check oil level sensors. Oil level sensors are in fault sensor

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to resistive analogue device connected to this analog input.
input 0 will be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On Analogue input 0 (resistive) (ANIA0): Data Valid but vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
32.00 520208 0 Corresponding Functional Error Above Normal Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to resistive analogue device connected to this analog input.
input 0 will be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On Analogue input 0 (resistive) (ANIA0): Data Valid but vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
32.01 520208 1 Corresponding Functional Error Below Normal Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to resistive analogue input 0 will - Check installation and operation of the device
be replaced by an appropriate default value. connected.
Lamp Status Depending On Analogue input 0 (resistive) (ANIA0): Voltage Above The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
32.03 520208 3 Corresponding Functional Error Normal, or Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to resistive analogue input 0 will - Check installation and operation of the device
be replaced by an appropriate default value. connected.
Lamp Status Depending On Analogue input 0 (resistive) (ANIA0): Voltage Below The TCON action depends on configured - refer to the other reported errors to identify
32.04 520208 4 Corresponding Functional Error Normal, or Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input 1 (resistive) (ANIA1): Data Valid but vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
33.00 520209 0 Corresponding Functional Error Above Normal Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input 1 (resistive) (ANIA1): Data Valid but vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
33.01 520209 1 Corresponding Functional Error Below Normal Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input 1 (resistive) (ANIA1): Voltage Above The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
33.03 520209 3 Corresponding Functional Error Normal, or Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input 1 (resistive) (ANIA1): Voltage Below The TCON action depends on configured - refer to the other reported errors to identify
33.04 520209 4 Corresponding Functional Error Normal, or Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

TCON will continue normal operation, but


the value of the analogue input function
connected to analogue input 0 will be
replaced by an appropriate default value. An analogue input function that needs to be - Perform a calibration of the connected device.
Lamp Status Depending On analogue input 1 (resistive) (ANIA1): Current Below This may result in reduced operation of the Contact maintenance for troubleshooting or calibrated is activated on analogue input 0 - Refer to the other reported errors to identify
33.05 520209 5 Corresponding Functional Error Normal, or Open Circuit vehicle. Perform a calibration of the connected device. and it has not been calibrated yet. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C0 (ANIC0): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
34.00 520210 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C0 (ANIC0): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
34.01 520210 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C0 (ANIC0): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
34.03 520210 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C0 (ANIC0): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
34.04 520210 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input C0 (ANIC0): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
34.0F 520210 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input C0 (ANIC0): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
34.11 520210 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C1 (ANIC1): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
35.00 520211 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C1 (ANIC1): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
35.01 520211 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C1 (ANIC1): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
35.03 520211 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C1 (ANIC1): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
35.04 520211 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input C1 (ANIC1): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
35.0F 520211 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input C1 (ANIC1): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
35.11 520211 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C2 (ANIC2): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
36.00 520212 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C2 (ANIC2): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
36.01 520212 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C2 (ANIC2): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
36.03 520212 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C2 (ANIC2): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
36.04 520212 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input C2 (ANIC2): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
36.0F 520212 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input C2 (ANIC2): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
36.11 520212 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C3 (ANIC3): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
37.00 520213 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C3 (ANIC3): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
37.01 520213 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C3 (ANIC3): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
37.03 520213 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C3 (ANIC3): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
37.04 520213 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input C3 (ANIC3): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
37.0F 520213 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input C3 (ANIC3): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
37.11 520213 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C4 (ANIC4): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
38.00 520214 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input 0 will device connected to this analog input.
be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input C4 (ANIC4): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
38.01 520214 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C4 (ANIC4): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
38.03 520214 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input 0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input C4 (ANIC4): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
38.04 520214 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input C4 (ANIC4): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
38.0F 520214 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input 0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input C4 (ANIC4): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
38.11 520214 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input A0 device connected to this analog input.
will be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input A0 (ANIA0): Data Valid but Above Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
3B.00 520217 0 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input function.

TCON will continue normal operation but - Recalibrate the input, if the problem persists,
the measurement of the analogue input check the wiring between the TCON and the
function connected to analogue input A0 device connected to this analog input.
will be affected. - Check installation and operation of the device
This may result in reduced operation of the connected.
Lamp Status Depending On analogue input A0 (ANIA0): Data Valid but Below Normal vehicle, the TCON action depends on Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
3B.01 520217 1 Corresponding Functional Error Operational Range - Most Severe configured analog input fiunction Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input A0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input A0 (ANIA0): Voltage Above Normal, or The TCON action depends on configured The input most likely has a loose connection - refer to the other reported errors to identify
3B.03 520217 3 Corresponding Functional Error Shorted To High Source analog input fiunction Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


The value of the analogue input function device connected to this analog input.
connected to analogue input A0 will be - Check installation and operation of the device
replaced by an appropriate default value. connected.
Lamp Status Depending On analogue input A0 (ANIA0): Voltage Below Normal, or The TCON action depends on configured - refer to the other reported errors to identify
3B.04 520217 4 Corresponding Functional Error Shorted To Low Source analog input fiunction Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input A0 will be - refer to the functional error of the attached
clipped to the highest value allowed. The device.
Lamp Status Depending On analogue input A0 (ANIA0): Data Valid but Above Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
3B.0F 520217 15 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
The value of the analogue input function connected device.
connected to analogue input A0 will be - refer to the functional error of the attached
clipped to the lowest value allowed. The device.
Lamp Status Depending On analogue input A0 (ANIA0): Data Valid but Below Normal TCON action depends on configured analog Contact maintenance for troubleshooting - Perform a calibration of the device attached to
3B.11 520217 17 Corresponding Functional Error Operational Range - Least Severe input fiunction The input is out of calibration. the input.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 0: Data Valid but Above Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% below the value if and which clutch is slipping. Check the
3C.00 520218 0 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 0: Data Valid but Below Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% above the value if and which clutch is slipping. Check the
3C.01 520218 1 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

Contact maintenance for troubleshooting Direction reporting error of the speed - Check the speed sensor
3C.02 520218 2 Stop Lamp Solid Speed input 0: Data Erratic, Intermittent, or Incorrect TCON will revert to limphome mode. sensor. - Check the wiring of the speed sensor
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate The measured current in the speed sensor - Check installation and operation of the speed
default value. circuit is below normal. The input most sensor connected.
Lamp Status Depending On The TCON action depends on the assigned Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
3C.05 520218 5 Corresponding Functional Error Speed input 0: Current Below Normal, or Open Circuit speed function. to battery plus (high source). the affected speed input function.

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate - Check installation and operation of the speed
default value. The measured current in the speed sensor sensor connected.
Lamp Status Depending On Speed input 0: Current Above Normal or Grounded The TCON action depends on the assigned Contact maintenance for troubleshooting circuit is above normal. The input is most - refer to the other reported errors to identify
3C.06 520218 6 Corresponding Functional Error Circuit speed function. likely shorted to ground (low source). the affected speed input function.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 1: Data Valid but Above Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% below the value if and which clutch is slipping. Check the
3D.00 520219 0 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 1: Data Valid but Below Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% above the value if and which clutch is slipping. Check the
3D.01 520219 1 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

Contact maintenance for troubleshooting Direction reporting error of the speed - Check the speed sensor
3D.02 520219 2 Stop Lamp Solid Speed input 1: Data Erratic, Intermittent, or Incorrect TCON will revert to limphome mode. sensor. - Check the wiring of the speed sensor

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate The measured current in the speed sensor - Check installation and operation of the speed
default value. circuit is below normal. The input most sensor connected.
Lamp Status Depending On The TCON action depends on the assigned Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
3D.05 520219 5 Corresponding Functional Error Speed input 1: Current Below Normal, or Open Circuit speed function. to battery plus (high source). the affected speed input function.

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate - Check installation and operation of the speed
default value. The measured current in the speed sensor sensor connected.
Lamp Status Depending On Speed input 1: Current Above Normal or Grounded The TCON action depends on the assigned Contact maintenance for troubleshooting circuit is above normal. The input is most - refer to the other reported errors to identify
3D.06 520219 6 Corresponding Functional Error Circuit speed function. likely shorted to ground (low source). the affected speed input function.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 2: Data Valid but Above Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% below the value if and which clutch is slipping. Check the
3E.00 520220 0 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 2: Data Valid but Below Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% above the value if and which clutch is slipping. Check the
3E.01 520220 1 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

Contact maintenance for troubleshooting Direction reporting error of the speed - Check the speed sensor
3E.02 520220 2 Stop Lamp Solid Speed input 2: Data Erratic, Intermittent, or Incorrect TCON will revert to limphome mode. sensor. - Check the wiring of the speed sensor

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate The measured current in the speed sensor - Check installation and operation of the speed
default value. circuit is below normal. The input most sensor connected.
Lamp Status Depending On The TCON action depends on the assigned Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
3E.05 520220 5 Corresponding Functional Error Speed input 2: Current Below Normal, or Open Circuit speed function. to battery plus (high source). the affected speed input function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate - Check installation and operation of the speed
default value. The measured current in the speed sensor sensor connected.
Lamp Status Depending On Speed input 2: Current Above Normal or Grounded The TCON action depends on the assigned Contact maintenance for troubleshooting circuit is above normal. The input is most - refer to the other reported errors to identify
3E.06 520220 6 Corresponding Functional Error Circuit speed function. likely shorted to ground (low source). the affected speed input function.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 3: Data Valid but Above Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% below the value if and which clutch is slipping. Check the
3F.00 520221 0 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

This message is given as additional The transmission ratio measured by the Check the transmission, in order to understand
Lamp Status Depending On Speed input 3: Data Valid but Below Normal Operational information for transmission ratio faults. Contact maintenance for troubleshooting controller is more than 5% above the value if and which clutch is slipping. Check the
3F.01 520221 1 Corresponding Functional Error Range - Most Severe The action is taken by ratio fault monitoring. of what is should be. transmission ratio settings of the controller.

Contact maintenance for troubleshooting Direction reporting error of the speed - Check the speed sensor
3F.02 520221 2 Stop Lamp Solid Speed input 3: Data Erratic, Intermittent, or Incorrect TCON will revert to limphome mode. sensor. - Check the wiring of the speed sensor

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate The measured current in the speed sensor - Check installation and operation of the speed
default value. circuit is below normal. The input most sensor connected.
Lamp Status Depending On The TCON action depends on the assigned Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
3F.05 520221 5 Corresponding Functional Error Speed input 3: Current Below Normal, or Open Circuit speed function. to battery plus (high source). the affected speed input function.

- Check the wiring between the TCON and the


The value of the assigned speed input device connected to this speed input.
function, will be replaced by an appropriate - Check installation and operation of the speed
default value. The measured current in the speed sensor sensor connected.
Lamp Status Depending On Speed input 3: Current Above Normal or Grounded The TCON action depends on the assigned Contact maintenance for troubleshooting circuit is above normal. The input is most - refer to the other reported errors to identify
3F.06 520221 6 Corresponding Functional Error Circuit speed function. likely shorted to ground (low source). the affected speed input function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 0: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
46.03 520224 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 0: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
46.04 520224 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
46.05 520224 5 Corresponding Functional Error Analog Output 0: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 0: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
46.06 520224 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 0: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
46.08 520224 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 1: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
47.03 520225 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 1: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
47.04 520225 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
47.05 520225 5 Corresponding Functional Error Analog Output 1: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 1: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
47.06 520225 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 1: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
47.08 520225 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 2: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
48.03 520226 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 2: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
48.04 520226 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
48.05 520226 5 Corresponding Functional Error Analog Output 2: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 2: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
48.06 520226 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 2: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
48.08 520226 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 3: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
49.03 520227 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 3: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
49.04 520227 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
49.05 520227 5 Corresponding Functional Error Analog Output 3: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 3: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
49.06 520227 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 3: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
49.08 520227 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 4: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
4A.03 520228 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 4: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
4A.04 520228 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
4A.05 520228 5 Corresponding Functional Error Analog Output 4: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 4: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
4A.06 520228 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 4: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
4A.08 520228 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

- Check the battery voltage


- Check the wiring between the TCON and the
devices connected to the analog outputs.
- Check installation and operation of the
Apply brakes and stop the vehicle. Turn power connected actuators.
off and restart the vehicle. If the problem A critical error on one or more of the analog - refer to the other reported errors to get more
Analog Outputs: Voltage Below Normal, or Shorted To persists, contact maintenance for outputs exists, which requires to shut off all information about the configured output
4B.04 520229 4 Stop Lamp Flashing Low Source TCON will revert to shutdown mode troubleshooting outputs. function.

- Check the wiring between the TCON and the


devices connected to the analog outputs.
- Check installation and operation of the
Apply brakes and stop the vehicle. Turn power connected actuators.
off and restart the vehicle. If the problem A critical error on one or more of the analog - refer to the other reported errors to get more
persists, contact maintenance for outputs exists, which requires to shut off all information about the configured output
4B.0B 520229 11 Stop Lamp Flashing Analog Outputs: Root Cause Not Known TCON will revert to shutdown mode troubleshooting outputs. function.

- Check the wiring between the TCON and the


devices connected to the analog outputs.
- Check installation and operation of the
Apply brakes and stop the vehicle. Turn power connected actuators.
off and restart the vehicle. If the problem A critical error on one or more of the analog - refer to the other reported errors to get more
persists, contact maintenance for outputs exists, which requires to shut off all information about the configured output
4B.1F 520229 31 Stop Lamp Flashing Analog Outputs: Failure exists TCON will revert to shutdown mode troubleshooting outputs. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 5: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
4C.03 520230 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 5: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
4C.04 520230 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
4C.05 520230 5 Corresponding Functional Error Analog Output 5: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 5: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
4C.06 520230 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 5: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
4C.08 520230 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 0: Voltage Above Normal, or Shorted activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
50.03 520231 3 Corresponding Functional Error To High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 0: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
50.04 520231 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 0: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
50.05 520231 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 1: Voltage Above Normal, or Shorted activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
51.03 520232 3 Corresponding Functional Error To High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 1: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
51.04 520232 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 1: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
51.05 520232 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 2: Voltage Above Normal, or Shorted activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
52.03 520233 3 Corresponding Functional Error To High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 2: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
52.04 520233 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 2: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
52.05 520233 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 3: Voltage Above Normal, or Shorted activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
53.03 520234 3 Corresponding Functional Error To High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 3: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
53.04 520234 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On High Side Output 3: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
53.05 520234 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 0: Voltage Above Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
54.03 520235 3 Corresponding Functional Error High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 0: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
54.04 520235 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 0: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
54.05 520235 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 1: Voltage Above Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
55.03 520236 3 Corresponding Functional Error High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 1: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
55.04 520236 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 1: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
55.05 520236 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 2: Voltage Above Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
56.03 520237 3 Corresponding Functional Error High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 2: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
56.04 520237 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 2: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
56.05 520237 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 3: Voltage Above Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. output detected the output is shorted to information about the configured output
57.03 520238 3 Corresponding Functional Error High Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. Dynamic checking by the TCON of the digital connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function output detected the output is shorted to - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 3: Voltage Below Normal, or Shorted To activated or deactivated state, possibly control will result in reduced vehicle operation. ground (low source), or the actuator wires information about the configured output
57.04 520238 4 Corresponding Functional Error Low Source resulting in reduced vehicle operation. Contact maintenance for troubleshooting. are shorted to each other. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
The assigned function can be blocked in the In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Low Side Output 3: Current Below Normal, or Open activated or deactivated state, possibly control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
57.05 520238 5 Corresponding Functional Error Circuit resulting in reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward clutch: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
94.03 520240 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward clutch: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
94.04 520240 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward clutch: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
94.05 520240 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: Forward clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
94.06 520240 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Forward clutch: Abnormal Frequency or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
94.08 520240 8 Stop Lamp Solid Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward High clutch: Voltage Above once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
95.03 520241 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward High clutch: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
95.04 520241 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Forward High clutch: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
95.05 520241 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: Forward High clutch: Current Above once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
95.06 520241 6 Stop Lamp Flashing Normal or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Forward High clutch: Abnormal mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
95.08 520241 8 Stop Lamp Solid Frequency or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Reverse clutch: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
96.03 520242 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Reverse clutch: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
96.04 520242 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Reverse clutch: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
96.05 520242 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: Reverse clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
96.06 520242 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Reverse clutch: Abnormal Frequency or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
96.08 520242 8 Stop Lamp Solid Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: stage1 clutch D: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
97.03 520243 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: stage1 clutch D: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
97.04 520243 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: stage1 clutch D: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
97.05 520243 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: stage1 clutch D: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
97.06 520243 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: stage1 clutch D: Abnormal Frequency mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
97.08 520243 8 Stop Lamp Solid or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 1st gear Clutch: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
98.03 520244 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 1st gear Clutch: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
98.04 520244 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 1st gear Clutch: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
98.05 520244 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: 1st gear Clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
98.06 520244 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: 1st gear Clutch: Abnormal Frequency or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
98.08 520244 8 Stop Lamp Solid Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 2nd gear Clutch: Voltage Above once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
99.03 520245 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 2nd gear Clutch: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
99.04 520245 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 2nd gear Clutch: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
99.05 520245 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: 2nd gear Clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
99.06 520245 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: 2nd gear Clutch: Abnormal Frequency mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
99.08 520245 8 Stop Lamp Solid or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 3rd gear Clutch: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
9A.03 520246 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 3rd gear Clutch: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
9A.04 520246 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 3rd gear Clutch: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
9A.05 520246 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: 3rd gear Clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
9A.06 520246 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: 3rd gear Clutch: Abnormal Frequency mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
9A.08 520246 8 Stop Lamp Solid or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 4th gear Clutch: Voltage Above Normal, once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
9B.03 520247 3 Stop Lamp Flashing or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 4th gear Clutch: Voltage Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
9B.04 520247 4 Stop Lamp Solid or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: 4th gear Clutch: Current Below Normal, mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
9B.05 520247 5 Stop Lamp Solid or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: 4th gear Clutch: Current Above Normal once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
9B.06 520247 6 Stop Lamp Flashing or Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: 4th gear Clutch: Abnormal Frequency mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
9B.08 520247 8 Stop Lamp Solid or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated Lockup: Voltage Above mode. Lockup will be disabled for further troubleshooting as soon as posible. analog output detected that the output is information about the configured output
9C.03 520248 3 Stop Lamp Solid Normal, or Shorted To High Source driving. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated Lockup: Voltage Below mode. Lockup will be disabled for further troubleshooting as soon as posible. output detected that the output is shorted information about the configured output
9C.04 520248 4 Stop Lamp Solid Normal, or Shorted To Low Source driving. Contact maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated Lockup: Current Below mode. Lockup will be disabled for further troubleshooting as soon as posible. analog output detected the output is in information about the configured output
9C.05 520248 5 Stop Lamp Solid Normal, or Open Circuit driving. Contact maintenance for troubleshooting. open circuit (loose connection). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for - refer to the other reported errors to get more
Output Function: Modulated Lockup: Current Above mode. Lockup will be disabled for further troubleshooting as soon as posible. Dynamic checking by the TCON ofthe analog information about the configured output
9C.06 520248 6 Stop Lamp Solid Normal or Grounded Circuit driving. Contact maintenance for troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Modulated Lockup: Abnormal mode. Lockup will be disabled for further troubleshooting as soon as posible. is out of range. This occurs when the load information about the configured output
9C.08 520248 8 Stop Lamp Solid Frequency or Pulse Width or Period driving. Contact maintenance for troubleshooting. has an incorrect impedance. function.
Output Function: Brake valve: Voltage Above Normal, or TCON will revert to transmission limphome
9D.03 520249 3 Stop Lamp Solid Shorted To High Source mode.
Output Function: Brake valve: Voltage Below Normal, or TCON will revert to transmission limphome
9D.04 520249 4 Stop Lamp Solid Shorted To Low Source mode.
Output Function: Brake valve: Current Below Normal, or TCON will revert to transmission limphome
9D.05 520249 5 Stop Lamp Solid Open Circuit mode.
Output Function: Brake valve: Current Above Normal or TCON will revert to transmission shutdown
9D.06 520249 6 Stop Lamp Solid Grounded Circuit mode.
Output Function: Brake valve: Abnormal Frequency or TCON will revert to transmission limphome
9D.08 520249 8 Stop Lamp Solid Pulse Width or Period mode.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated retarder output: Voltage once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
9E.03 520250 3 Stop Lamp Flashing Above Normal, or Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated retarder output: Voltage mode. The retarder will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
9E.04 520250 4 Stop Lamp Solid Below Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Modulated retarder output: Current mode. The retarder will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
9E.05 520250 5 Stop Lamp Solid Below Normal, or Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for - refer to the other reported errors to get more
Output Function: Modulated retarder output: Current mode. The retarder will be disabled for troubleshooting as soon as posible. Contact Dynamic checking by the TCON ofthe analog information about the configured output
9E.06 520250 6 Stop Lamp Solid Above Normal or Grounded Circuit further driving. maintenance for troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Modulated retarder output: Abnormal mode. The retarder will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
9E.08 520250 8 Stop Lamp Solid Frequency or Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Warning Light: Voltage Above Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A0.03 520252 3 Amber Warning Solid or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Warning Light: Voltage Below Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A0.04 520252 4 Amber Warning Solid or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Warning Light: Current Below Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A0.05 520252 5 Amber Warning Solid or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A0.09 520252 9 Amber Warning Solid Output Function: Warning Light: Abnormal Update Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Digital Temperature indication: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A1.03 520253 3 Amber Warning Solid Above Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Digital Temperature indication: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A1.04 520253 4 Amber Warning Solid Below Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Digital Temperature indication: Current TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A1.05 520253 5 Amber Warning Solid Below Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Digital Temperature indication: this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A1.09 520253 9 Amber Warning Solid Abnormal Update Rate over CAN. constructed.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
- Check if digital output has its expected value
and if the mechanical actuator has made the
switch.
Output Function: 4WD/2WD: Data Valid but Above Contact maintenance for troubleshooting The mechanical actuator is stuck engaged or - Check if the digital feedback is switched and
A2.00 520254 0 Amber warning Flashing Normal Operational Range - Most Severe TCON will try to actuate the output. the feedback line is faulty. still connected to the controller.
- Check if digital output has its expected value
and if the mechanical actuator has made the
switch.
Output Function: 4WD/2WD: Data Valid but Below Contact maintenance for troubleshooting The mechanical actuator is stuck - Check if the digital feedback is switched and
A2.01 520254 1 Amber warning Flashing Normal Operational Range - Most Severe TCON will try to actuate the output. disengaged or the feedback line is faulty. still connected to the controller.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: 4WD/2WD: Voltage Above Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A2.03 520254 3 Amber warning Flashing Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: 4WD/2WD: Voltage Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A2.04 520254 4 Amber warning Flashing Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: 4WD/2WD: Current Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A2.05 520254 5 Amber warning Flashing Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A2.09 520254 9 Amber warning Flashing Output Function: 4WD/2WD: Abnormal Update Rate over CAN. constructed.
- Check if digital output has its expected value
and if the mechanical actuator has made the
switch.
Output Function: Low/High range: Data Valid but Above Contact maintenance for troubleshooting The mechanical actuator is stuck engaged or - Check if the digital feedback is switched and
A3.00 520255 0 Amber warning Flashing Normal Operational Range - Most Severe TCON will try to actuate the output. the feedback line is faulty. still connected to the controller.
- Check if digital output has its expected value
and if the mechanical actuator has made the
switch.
Output Function: Low/High range: Data Valid but Below Contact maintenance for troubleshooting The mechanical actuator is stuck - Check if the digital feedback is switched and
A3.01 520255 1 Amber warning Flashing Normal Operational Range - Most Severe TCON will try to actuate the output. disengaged or the feedback line is faulty. still connected to the controller.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Low/High range: Voltage Above TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A3.03 520255 3 Amber warning Flashing Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Low/High range: Voltage Below TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A3.04 520255 4 Amber warning Flashing Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Low/High range: Current Below TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A3.05 520255 5 Amber warning Flashing Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Low/High range: Abnormal Update this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A3.09 520255 9 Amber warning Flashing Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Speed dependant output: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A4.03 520256 3 Amber Warning Solid Above Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Speed dependant output: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A4.04 520256 4 Amber Warning Solid Below Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Speed dependant output: Current TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A4.05 520256 5 Amber Warning Solid Below Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Speed dependant output: Abnormal this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A4.09 520256 9 Amber Warning Solid Update Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Parking brake: Voltage Above Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A5.03 520257 3 Amber warning Flashing or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Parking brake: Voltage Below Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A5.04 520257 4 Amber warning Flashing or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Parking brake: Current Below Normal, TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A5.05 520257 5 Amber warning Flashing or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A5.09 520257 9 Amber warning Flashing Output Function: Parking brake: Abnormal Update Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Parking brake light: Voltage Above TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A6.03 520258 3 Amber warning Flashing Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Parking brake light: Voltage Below TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A6.04 520258 4 Amber warning Flashing Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Parking brake light: Current Below TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A6.05 520258 5 Amber warning Flashing Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Parking brake light: Abnormal Update this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A6.09 520258 9 Amber warning Flashing Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Output Function: On/Off Lockup: Voltage Above Normal, mode. Lockup will be disabled for further troubleshooting as soon as posible. output detected that the output is shorted information about the configured output
A7.03 520259 3 Stop Lamp Solid or Shorted To High Source driving. Contact maintenance for troubleshooting. to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Output Function: On/Off Lockup: Voltage Below Normal, mode. Lockup will be disabled for further troubleshooting as soon as posible. output detected that the output is shorted information about the configured output
A7.04 520259 4 Stop Lamp Solid or Shorted To Low Source driving. Contact maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the digital - refer to the other reported errors to get more
Output Function: On/Off Lockup: Current Below Normal, mode. Lockup will be disabled for further troubleshooting as soon as posible. output detected the output is in open information about the configured output
A7.05 520259 5 Stop Lamp Solid or Open Circuit driving. Contact maintenance for troubleshooting. circuit (loose connection). function.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A7.09 520259 9 Amber warning Flashing Output Function: On/Off Lockup: Abnormal Update Rate over CAN. constructed.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Exhaust: Voltage Above Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A8.03 520260 3 Amber warning Flashing Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Exhaust: Voltage Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A8.04 520260 4 Amber warning Flashing Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Exhaust: Current Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A8.05 520260 5 Amber warning Flashing Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A8.09 520260 9 Amber warning Flashing Output Function: Exhaust: Abnormal Update Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Retarder On/Off - Selector: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
A9.03 520261 3 Amber warning Flashing Above Normal, or Shorted To High Source the retarder function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Retarder On/Off - Selector: Voltage TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
A9.04 520261 4 Amber warning Flashing Below Normal, or Shorted To Low Source the retarder function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Retarder On/Off - Selector: Current TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
A9.05 520261 5 Amber warning Flashing Below Normal, or Open Circuit the retarder function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Retarder On/Off: Abnormal Update this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
A9.09 520261 9 Amber warning Flashing Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Towing: Voltage Above Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
AA.03 520262 3 Amber warning Flashing Shorted To High Source this output function will be disabled. source). information about the digital output.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Towing: Voltage Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
AA.04 520262 4 Amber warning Flashing Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Towing: Current Below Normal, or TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
AA.05 520262 5 Amber warning Flashing Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
AA.09 520262 9 Amber warning Flashing Output Function: Towing: Abnormal Update Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Overspeeding Light: Voltage Above TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
AB.03 520263 3 Amber warning Flashing Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Overspeeding Light: Voltage Below TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
AB.04 520263 4 Amber warning Flashing Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Overspeeding Light: Current Below TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
AB.05 520263 5 Amber warning Flashing Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Overspeeding Light: Abnormal Update this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
AB.09 520263 9 Amber warning Flashing Rate over CAN. constructed.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward clutch selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AC.03 520264 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward clutch selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AC.04 520264 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward clutch selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
AC.05 520264 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward High clutch selector: Voltage mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AD.03 520265 3 Stop Lamp Solid Above Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward High clutch selector: Voltage mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AD.04 520265 4 Stop Lamp Solid Below Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Forward High clutch selector: Current mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
AD.05 520265 5 Stop Lamp Solid Below Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Reverse clutch selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AE.03 520266 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Reverse clutch selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AE.04 520266 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: Reverse clutch selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
AE.05 520266 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: stage1 clutch D selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AF.03 520267 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: stage1 clutch D selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
AF.04 520267 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: stage1 clutch D selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
AF.05 520267 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 1st gear Clutch selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B0.03 520268 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 1st gear Clutch selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B0.04 520268 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 1st gear Clutch selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
B0.05 520268 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 2nd gear Clutch selector: Voltage mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B1.03 520269 3 Stop Lamp Solid Above Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 2nd gear Clutch selector: Voltage mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B1.04 520269 4 Stop Lamp Solid Below Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 2nd gear Clutch selector: Current mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
B1.05 520269 5 Stop Lamp Solid Below Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 3rd gear Clutch selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B2.03 520270 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 3rd gear Clutch selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B2.04 520270 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 3rd gear Clutch selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
B2.05 520270 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 4th gear Clutch selector: Voltage Above mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B3.03 520271 3 Stop Lamp Solid Normal, or Shorted To High Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 4th gear Clutch selector: Voltage Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted - Check installation and operation of the
B3.04 520271 4 Stop Lamp Solid Normal, or Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). connected actuator.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can


still operate the vehicle (reduced vehicle - Check the wiring between the TCON and the
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the device connected to this output.
Output Function: 4th gear Clutch selector: Current Below mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected the output is in open - Check installation and operation of the
B3.05 520271 5 Stop Lamp Solid Normal, or Open Circuit further driving. maintenance for troubleshooting. circuit (loose connection). connected actuator.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch Low: Voltage Above Normal, or once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
B4.03 520272 3 Stop Lamp Flashing Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch Low: Voltage Below Normal, or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
B4.04 520272 4 Stop Lamp Solid Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch Low: Current Below Normal, or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
B4.05 520272 5 Stop Lamp Solid Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: Clutch Low: Current Above Normal or once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
B4.06 520272 6 Stop Lamp Flashing Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Clutch Low: Abnormal Frequency or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
B4.08 520272 8 Stop Lamp Solid Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch High: Voltage Above Normal, or once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
B5.03 520273 3 Stop Lamp Flashing Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch High: Voltage Below Normal, or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact output detected that the output is shorted information about the configured output
B5.04 520273 4 Stop Lamp Solid Shorted To Low Source further driving. maintenance for troubleshooting. to ground (low source). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for Dynamic checking by the TCON of the - refer to the other reported errors to get more
Output Function: Clutch High: Current Below Normal, or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact analog output detected the output is in information about the configured output
B5.05 520273 5 Stop Lamp Solid Open Circuit further driving. maintenance for troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Output Function: Clutch High: Current Above Normal or once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
B5.06 520273 6 Stop Lamp Flashing Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
In transmission limphome mode, the driver can - Check installation and operation of the
still operate the vehicle (reduced vehicle connected actuator.
TCON will revert to transmission limphome operation). Return to a service center for The TCON detected that the output current - refer to the other reported errors to get more
Output Function: Clutch High: Abnormal Frequency or mode. This clutch will be disabled for troubleshooting as soon as posible. Contact is out of range. This occurs when the load information about the configured output
B5.08 520273 8 Stop Lamp Solid Pulse Width or Period further driving. maintenance for troubleshooting. has an incorrect impedance. function.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Reverse Alert output: Voltage Above TCON will continue normal operation, but Contact maintenance for troubleshooting function is shorted to battery plus (high - Refer to the other reported errors to get more
B8.03 520276 3 Amber warning Flashing Normal, or Shorted To High Source this output function will be disabled. source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
connection.
Output Function: Reverse Alert output: Voltage Below TCON will continue normal operation, but Contact maintenance for troubleshooting The digital output assigned to this output - Refer to the other reported errors to get more
B8.04 520276 4 Amber warning Flashing Normal, or Shorted To Low Source this output function will be disabled. function is shorted to ground (low source). information about the digital output.

- Check the wiring between the TCON and the


device connected to this digital output.
- Check installation and operation of the
The digital output assigned to this output connection.
Output Function: Reverse Alert output: Current Below TCON will continue normal operation, but Contact maintenance for troubleshooting function is in open circuit (loose - Refer to the other reported errors to get more
B8.05 520276 5 Amber warning Flashing Normal, or Open Circuit this output function will be disabled. connection). information about the digital output.
TCON will continue normal operation, but CAN message containing value for the Check if the CAN message containing the output
Output Function: Reverse Alert output: Abnormal Update this output function will not be broadcasted Contact maintenance for troubleshooting output function cannot be broadcasted or function is configured.
B8.09 520276 9 Amber warning Flashing Rate over CAN. constructed.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will force the torque limiter clutch - Check installation and operation of the
open. This will result in inoperability of the connected actuator.
vehicle. TCON will only resume normal - refer to the other reported errors to get more
Torque Limiter: Data Valid but Above Normal operation after the shiftlever is cycled Contact maintenance for troubleshooting The slip in the torque limiter has exceeded information about the configured output
B9.00 520277 0 Amber warning Flashing Operational Range - Most Severe through neutral. the maximum allowed time. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Torque Limiter: Clutch High: Voltage Above Normal, or once the error is cleared and TCON is posible. Contact maintenance for analog output detected that the output is information about the configured output
B9.03 520277 3 Stop Lamp Flashing Shorted To High Source restarted. troubleshooting. shorted to battery plus (high source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Torque Limiter: Clutch High: Voltage Below Normal, or once the error is cleared and TCON is posible. Contact maintenance for output detected that the output is shorted information about the configured output
B9.04 520277 4 Stop Lamp Flashing Shorted To Low Source restarted. troubleshooting. to ground (low source). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as Dynamic checking by the TCON of the - refer to the other reported errors to get more
Torque Limiter: Clutch High: Current Below Normal, or once the error is cleared and TCON is posible. Contact maintenance for analog output detected the output is in information about the configured output
B9.05 520277 5 Stop Lamp Flashing Open Circuit restarted. troubleshooting. open circuit (loose connection). function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as - refer to the other reported errors to get more
Torque Limiter: Clutch High: Current Above Normal or once the error is cleared and TCON is posible. Contact maintenance for Dynamic checking by the TCON ofthe analog information about the configured output
B9.06 520277 6 Stop Lamp Flashing Grounded Circuit restarted. troubleshooting. output detected an overcurrent. function.

- Check the wiring between the TCON and the


device connected to this analog output.
TCON will revert to shutdown mode. This In transmission shutdown mode, the driver can - Check installation and operation of the
will result in inoperability of the vehicle. no longer operate the vehicle. Return to a connected actuator.
TCON will only resume normal operation service center for troubleshooting as soon as The TCON detected that the output current - refer to the other reported errors to get more
Torque Limiter: Clutch High: Abnormal Frequency or once the error is cleared and TCON is posible. Contact maintenance for is out of range. This occurs when the load information about the configured output
B9.08 520277 8 Stop Lamp Flashing Pulse Width or Period restarted. troubleshooting. has an incorrect impedance. function.

TCON will force the transmission in neutral


as protection mechanism, as too much
torque going through the transmission can Engine speed or torque is above
Engine speed / torque exceeds allowed max speed / cause damage. TCON will only resume Reduce engine speed or power. Recycle commanded engine speed or torque limit - Check if engine control is following engine
torque: Data Valid but Above Normal Operational Range - normal operation after the shiftlever is shiftlever through neutral to reset the for too long. Transmission protection forced command provided by TCON
BA.00 520278 0 Amber warning Flashing Most Severe. cycled through neutral. protection mechanism. neutral - check CAN communication

Engine speed / torque exceeds allowed max speed / TCON will continue normal operation. If the Engine speed or torque is above - Check if engine control is following engine
torque: Data Valid but Above Normal Operational Range - overtorque or overspeed condition persists, commanded engine speed or torque limit command provided by TCON
BA.0F 520278 15 Protection Lamp Least Severe. TCON will escalate this warning into FMI 0. Reduce engine speed or power. for limited duration. - check CAN communication
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle.
TCON will only resume normal operation
direction selection: shift lever: Data Erratic, Intermittent, once the error is cleared and TCON is Contact maintenance for troubleshooting The expected value for the direction Check the wiring between the TCON and the
28.02 520286 2 Stop Lamp Flashing or Incorrect restarted. selection contains an invalid pattern. shiftlever concerning the direction signals.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. CAN message containing value for the - Check if CAN message containing the shiftlever
TCON will only resume normal operation shiftelver function not received within the function value is sent correctly on the CAN bus.
once the error is cleared and TCON is Contact maintenance for troubleshooting expected timeframe or not present on the - Check if the repetition rate of the CAN
28.09 520286 9 Stop Lamp Flashing direction selection: shift lever: Abnormal Update Rate restarted. CAN bus. message is fast enough.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the shiftlever
TCON will only resume normal operation function received by the corresponding CAN Check the source signal from the CAN message
direction selection: shift lever: Received Network Data in once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the shiftlever function for requesting
28.13 520286 19 Stop Lamp Flashing Error restarted. value. a valid value.
TCON will continue normal operation, but
the value of the gear shift lever will be
replaced by the closest corresponding
value.
gear selection: shift lever: Data Erratic, Intermittent, or This may result in reduced operation of the Contact maintenance for troubleshooting The expected value for the gear selection Check the wiring between the TCON and the
29.02 520287 2 Amber warning Flashing Incorrect vehicle. contains an invalid pattern. shiftlever concerning the gear signals.
TCON will continue normal operation, but
the value of the gear shift lever will be
replaced by the closest corresponding CAN message containing value for the - Check if CAN message containing the shiftlever
value. shiftelver function not received within the function value is sent correctly on the CAN bus.
This may result in reduced operation of the Contact maintenance for troubleshooting expected timeframe or not present on the - Check if the repetition rate of the CAN
29.09 520287 9 Amber warning Flashing gear selection: shift lever: Abnormal Update Rate vehicle. CAN bus. message is fast enough.
TCON will continue normal operation, but
the value of the gear shift lever will be
replaced by the closest corresponding The expected value for the shiftlever
value. function received by the corresponding CAN Check the source signal from the CAN message
gear selection: shift lever: Received Network Data in This may result in reduced operation of the Contact maintenance for troubleshooting message contains an invalid or unavailable containing the shiftlever function for requesting
29.13 520287 19 Amber warning Flashing Error vehicle. value. a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Shift lever Selection Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
2D.09 520288 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function will be The expected value for the input function
replaced by the default value. received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Shift lever Selection Received This will result in reduced operation of the message contains an invalid or unavailable containing the input function for requesting a
2D.13 520288 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting value. valid value.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 6: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
4D.03 520294 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 6: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
4D.04 520294 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
4D.05 520294 5 Corresponding Functional Error Analog Output 6: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 6: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
4D.06 520294 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 6: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
4D.08 520294 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 7: Voltage Above Normal, or Shorted To control will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected that the output is information about the configured output
4E.03 520295 3 Corresponding Functional Error High Source reduced vehicle operation. Contact maintenance for troubleshooting. shorted to battery plus (high source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 7: Voltage Below Normal, or Shorted To will be disabled, possibly resulting in control will result in reduced vehicle operation. output detected that the output is shorted information about the configured output
4E.04 520295 4 Corresponding Functional Error Low Source reduced vehicle operation. Contact maintenance for troubleshooting. to ground (low source). function.

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function Dynamic checking by the TCON of the - refer to the other reported errors to get more
Lamp Status Depending On will be disabled, possibly resulting in control will result in reduced vehicle operation. analog output detected the output is in information about the configured output
4E.05 520295 5 Corresponding Functional Error Analog Output 7: Current Below Normal, or Open Circuit reduced vehicle operation. Contact maintenance for troubleshooting. open circuit (loose connection). function.

In transmission shutdown mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission no longer operate the vehicle. Return to a device connected to this analog output.
control function assigned to it, TCON will service center for troubleshooting as soon as - Check installation and operation of the
revert to transmission shutdown mode. posible. connected actuator.
In all other cases the assigned function In all other cases disabling the assigned function - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 7: Current Above Normal or Grounded control will be disabled, possibly resulting in control will result in reduced vehicle operation. Dynamic checking by the TCON ofthe analog information about the configured output
4E.06 520295 6 Corresponding Functional Error Circuit reduced vehicle operation. Contact maintenance for troubleshooting. output detected an overcurrent. function.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

In transmission limphome mode, the driver can - Check the wiring between the TCON and the
If the output has a critical transmission still operate the vehicle (reduced vehicle device connected to this analog output.
control function assigned to it, TCON will operation). Return to a service center for - Check installation and operation of the
revert to transmission limphome mode. troubleshooting as soon as posible. connected actuator.
In any case the assigned function control In all other cases disabling the assigned function The TCON detected that the output current - refer to the other reported errors to get more
Lamp Status Depending On Analog Output 7: Abnormal Frequency or Pulse Width or will be disabled, possibly resulting in control will result in reduced vehicle operation. is out of range. This occurs when the load information about the configured output
4E.08 520295 8 Corresponding Functional Error Period reduced vehicle operation. Contact maintenance for troubleshooting. has an incorrect impedance. function.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B0 (ANIB0): Data Valid but Above Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
15.00 520297 0 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B0 (ANIB0): Data Valid but Below Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
15.01 520297 1 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B0 (ANIB0): Voltage Above Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
15.03 520297 3 Corresponding Functional Error Shorted To High Source functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B0 (ANIB0): Voltage Below Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
15.04 520297 4 Corresponding Functional Error Shorted To Low Source functional error of the configured input. configured input. input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B0 (ANIB0): Data Valid but Above Normal the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
15.0F 520297 15 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B0 (ANIB0): Data Valid but Below Normal the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
15.11 520297 17 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B1 (ANIB1): Data Valid but Above Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
16.00 520298 0 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B1 (ANIB1): Data Valid but Below Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
16.01 520298 1 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B1 (ANIB1): Voltage Above Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
16.03 520298 3 Corresponding Functional Error Shorted To High Source functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B1 (ANIB1): Voltage Below Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
16.04 520298 4 Corresponding Functional Error Shorted To Low Source functional error of the configured input. configured input. input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B1 (ANIB1): Data Valid but Above Normal the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
16.0F 520298 15 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B1 (ANIB1): Data Valid but Below Normal the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
16.11 520298 17 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B2 (ANIB2): Data Valid but Above Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
17.00 520299 0 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B2 (ANIB2): Data Valid but Below Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
17.01 520299 1 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B2 (ANIB2): Voltage Above Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
17.03 520299 3 Corresponding Functional Error Shorted To High Source functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B2 (ANIB2): Voltage Below Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
17.04 520299 4 Corresponding Functional Error Shorted To Low Source functional error of the configured input. configured input. input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B2 (ANIB2): Data Valid but Above Normal the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
17.0F 520299 15 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B2 (ANIB2): Data Valid but Below Normal the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
17.11 520299 17 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B3 (ANIB3): Data Valid but Above Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
18.00 520300 0 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B3 (ANIB3): Data Valid but Below Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
18.01 520300 1 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B3 (ANIB3): Voltage Above Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
18.03 520300 3 Corresponding Functional Error Shorted To High Source functional error of the configured input. configured input. input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B3 (ANIB3): Voltage Below Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
18.04 520300 4 Corresponding Functional Error Shorted To Low Source functional error of the configured input. configured input. input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B3 (ANIB3): Data Valid but Above Normal the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
18.0F 520300 15 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B3 (ANIB3): Data Valid but Below Normal the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
18.11 520300 17 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B4 (ANIB4): Data Valid but Above Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
19.00 520301 0 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B4 (ANIB4): Data Valid but Below Normal will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
19.01 520301 1 Corresponding Functional Error Operational Range - Most Severe functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B4 (ANIB4): Voltage Above Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
19.03 520301 3 Corresponding Functional Error Shorted To High Source functional error of the configured input. configured input. input.

Depending on the configurated input, TCON


Lamp Status Depending On Analog input B4 (ANIB4): Voltage Below Normal, or will take the necessary action. Refer to the Contact maintenance for troubleshooting Refer to the functional error of the Refer to the functional error of the configured
19.04 520301 4 Corresponding Functional Error Shorted To Low Source functional error of the configured input. configured input. input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B4 (ANIB4): Data Valid but Above Normal the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
19.0F 520301 15 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Lamp Status Depending On Analog input B4 (ANIB4): Data Valid but Below Normal the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
19.11 520301 17 Corresponding Functional Error Operational Range - Least Severe this analog input. The input is out of calibration. the input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. Measured pressure on this sensor is too
TCON will only resume normal operation high: - Check lube pressure at engine idle.
Input Function: Lube Pressure: Data Valid but Above once the error is cleared and TCON is Contact maintenance for troubleshooting - Bad wire Log pressure (CAN trace or other measurement
09.00 520303 0 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Hydraulic failure equipment) when problem occurs.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check oil level.


- Check supply pressure to the transmission at
TCON will revert to shutdown mode. This engine idle.
will result in inoperability of the vehicle. Measured pressure on this sensor is too - Check clutch pressure at engine idle when
TCON will only resume normal operation low: clutch is selected.
Input Function: Lube Pressure: Data Valid but Below once the error is cleared and TCON is Contact maintenance for troubleshooting - Bad wire Log pressure (CAN trace or other measurement
09.01 520303 1 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Hydraulic failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Lube Pressure: Voltage Above Normal, or once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
09.03 520303 3 Stop Lamp Flashing Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Lube Pressure: Voltage Below Normal, or once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
09.04 520303 4 Stop Lamp Flashing Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
09.09 520303 9 Stop Lamp Flashing Input Function: Lube Pressure: Abnormal Update Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Lube Pressure: Received Network Data in once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
09.13 520303 19 Stop Lamp Flashing Error restarted. value. valid value.

Default action: TCON will revert to


shutdown mode. This will result in - Check clutch pressure at engine idle when
inoperability of the vehicle. TCON will only Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
resume normal operation once the error is high in comparison with the commanded - Check clutch pressure at engine idle when
cleared and TCON is restarted. pressure by TCON: clutch is selected.
Input Function: Forward Clutch Pressure: Data Valid but Alternative action: The TCON will revert to Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0A.00 520304 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe transmission limphome mode. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: Forward Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0A.01 520304 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Forward Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0A.03 520304 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Forward Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0A.04 520304 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Forward Clutch Pressure: Abnormal once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0A.09 520304 9 Stop Lamp Flashing Update Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Forward Clutch Pressure: Received once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0A.13 520304 19 Stop Lamp Flashing Network Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: Reverse Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0B.00 520305 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: Reverse Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0B.01 520305 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Reverse Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0B.03 520305 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Reverse Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0B.04 520305 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Reverse Clutch Pressure: Abnormal once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0B.09 520305 9 Stop Lamp Flashing Update Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Reverse Clutch Pressure: Received once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0B.13 520305 19 Stop Lamp Flashing Network Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: Forward High Clutch Pressure: Data Valid once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0C.00 520306 0 Stop Lamp Flashing but Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: Forward High Clutch Pressure: Data Valid once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0C.01 520306 1 Stop Lamp Flashing but Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Forward High Clutch Pressure: Voltage once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0C.03 520306 3 Stop Lamp Flashing Above Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Forward High Clutch Pressure: Voltage once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0C.04 520306 4 Stop Lamp Flashing Below Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Forward High Clutch Pressure: Abnormal once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0C.09 520306 9 Stop Lamp Flashing Update Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Forward High Clutch Pressure: Received once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0C.13 520306 19 Stop Lamp Flashing Network Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: 1st Clutch Pressure: Data Valid but Above once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0D.00 520307 0 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: 1st Clutch Pressure: Data Valid but Below once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0D.01 520307 1 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 1st Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0D.03 520307 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 1st Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0D.04 520307 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: 1st Clutch Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0D.09 520307 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: 1st Clutch Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0D.13 520307 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: 2nd Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0E.00 520308 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: 2nd Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0E.01 520308 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 2nd Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0E.03 520308 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 2nd Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0E.04 520308 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: 2nd Clutch Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0E.09 520308 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: 2nd Clutch Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0E.13 520308 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: 3rd Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
0F.00 520309 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: 3rd Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
0F.01 520309 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 3rd Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
0F.03 520309 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 3rd Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
0F.04 520309 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: 3rd Clutch Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
0F.09 520309 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: 3rd Clutch Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
0F.13 520309 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: 4th Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
10.00 520310 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: 4th Clutch Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
10.01 520310 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 4th Clutch Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
10.03 520310 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: 4th Clutch Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
10.04 520310 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: 4th Clutch Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
10.09 520310 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: 4th Clutch Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
10.13 520310 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

By using the retarder diagnostic mode:


TCON will revert to shutdown mode. This Measured pressure on this sensor is too - Check pressure when retarder is NOT selected
will result in inoperability of the vehicle. high in comparison with the commanded (+-0 bar required).
TCON will only resume normal operation pressure by TCON: - Check pressure when retarder is selected.
Input Function: Retarder Pressure: Data Valid but Above once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
11.00 520311 0 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low


in comparison with the commanded By using the retarder diagnostic mode:
TCON will revert to shutdown mode. This pressure by TCON: - Check pressure when retarder is NOT selected
will result in inoperability of the vehicle. - Supply pressure to transmission too low. (+-0 bar required).
TCON will only resume normal operation - Proportional solenoid stuck. - Check pressure when retarder is selected.
Input Function: Retarder Pressure: Data Valid but Below once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
11.01 520311 1 Stop Lamp Flashing Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. check wiring and voltage state of the pins of the
TCON will only resume normal operation retarder pressure sensor
Input Function: Retarder Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection Log pressure (CAN trace or other measurement
11.03 520311 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. equipment) when problem occurs.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. check wiring and voltage state of the pins of the
TCON will only resume normal operation retarder pressure sensor
Input Function: Retarder Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting Log pressure (CAN trace or other measurement
11.04 520311 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. equipment) when problem occurs.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Retarder Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
11.09 520311 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Retarder Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
11.13 520311 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

Measured pressure on this sensor is too - Check clutch pressure at engine idle when
TCON will continue normal operation but high in comparison with the commanded clutch is NOT selected (+-0 bar required).
lockup will be unavailable. TCON will only pressure by TCON: - Check clutch pressure when clutch is selected.
Lockup Pressure: Data Valid but Above Normal try to reactivate lockup when TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
45.00 520312 0 Amber warning Flashing Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
pressure by TCON: engine idle.
TCON will continue normal operation but - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
lockup will be unavailable. TCON will only - Proportional solenoid stuck. clutch is selected.
Lockup Pressure: Data Valid but Below Normal try to reactivate lockup when TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
45.01 520312 1 Amber warning Flashing Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the TCON and the


pressure sensor connected to this analog input.
TCON will continue normal operation but - Check installation and operation of the
lockup will be unavailable. TCON will only connected pressure sensor.
Lockup Pressure: Voltage Above Normal, or Shorted To try to reactivate lockup when TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
45.03 520312 3 Amber warning Flashing High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


pressure sensor connected to this analog input.
TCON will continue normal operation but - Check installation and operation of the
lockup will be unavailable. TCON will only connected pressure sensor.
Lockup Pressure: Voltage Below Normal, or Shorted To try to reactivate lockup when TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
45.04 520312 4 Amber warning Flashing Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will continue to use the lockup logic. - The lockup valve has no sufficient
Lockup engaged but turbine and impeller have speed However, this might result in reduced Contact maintenance for troubleshooting pressure. -Check pressure lockup valve
45.07 520312 7 Amber warning Flashing difference operability of the vehicle. - lockup clutch failure - Check lockup actuator

The expected value for the input function, Check the source signal from the CAN message
received by the corresponding CAN containing the input function for requesting a
TCON will continue normal operation but Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
45.09 520312 9 Amber warning Flashing Lockup Pressure: Abnormal Update Rate lockup will be unavailable. value. Check the can bus communication.

The expected value for the input function


received by the corresponding CAN Check the source signal from the CAN message
TCON will continue normal operation but Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
45.13 520312 19 Amber warning Flashing Lockup Pressure: Received Network Data in Error lockup will be unavailable. value. valid value.

- probably no servicing action needed, just


temporary reduction of vehicle usage intensity
Release the inching pedal and cycle the to allow transmission to cool down.
Inching torque: Data Valid but Above Normal Operational TCON will open or close the inching clutch shiftlever via neutral back in the selected The transmission has exceeded the - if problem persists, Check functioning of
2E.0F 520313 15 Amber Warning Solid Range - Least Severe depending of the GDE parameter selection. direction in order to get drive again. maximum torque during inching. transmission cooler.
- Check the wiring between the TCON and CAN
interface.
The auxiliary motor speed is too low to - Check the source controller that is sending this
Speed Sensor Input Function: Auxiliary motor speed: guarantee safe operation. Transmission can signal.
Data Valid but Below Normal Operational Range - Most TCON will revert to transmission shutdown become damaged due to insufficient - refer to the other reported errors to identify
75.01 520314 1 Stop Lamp Flashing Severe mode. Contact maintenance for troubleshooting auxiliary motor speed. the affected speed input.

- Check if CAN message containing the


The auxiliary motor speed is missing and intermediate speed value is sent correctly on
therefore the TCON can't guarantee safe the CAN bus.
operation. Transmission can become - Check if the repetition rate of that CAN
Speed Sensor Input Function: Auxiliary motor speed: TCON will revert to transmission shutdown damaged due to insufficient auxiliary motor message is fast enough.
75.09 520314 9 Stop Lamp Flashing Abnormal Update Rate mode. Contact maintenance for troubleshooting speed. - Check CAN connection to the controller.

The auxiliary motor speed is missing and


therefore the TCON can't guarantee safe
operation. Transmission can become
Speed Sensor Input Function: Auxiliary motor speed: TCON will revert to transmission shutdown damaged due to insufficient auxiliary motor - Check source of broadcast.
75.13 520314 19 Stop Lamp Flashing Received Network Data in Error mode. Contact maintenance for troubleshooting speed. - Check CAN connection to the controller.

TCON detected overspeeding conditions.


Depending on the settings, the controller
migth upshift to a higher gear and
eventualy go to a neutral zero state. The
Transmission limit: Data Valid but Above Normal error code remains active until the Transmission input or output speed is too -slow down vehicle by applying brakes or
2F.00 520315 0 Amber warning Flashing Operational Range - Most Severe corrective action is reset. Release the throttle pedal, and apply brakes. high. releasing throttle pedal
The value of the engine speed sensor, will
be replaced by an appropriate calculated
value. Check can connection to the VSM. Run trace
Speed Sensor Input Function: Engine speed: Data Valid The TCON will revert to transmission Engine speed is above commanded engine when problem occurs. Check for engine speed
41.00 520316 0 Stop Lamp Solid but Above Normal Operational Range - Most Severe limphome mode. Contact maintenance for troubleshooting speed limit for 2 seconds. response on limit request by controller.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
The value of the engine speed sensor, will
be replaced by an appropriate calculated - Check the transmission and speed sensors.
value. - Check the speed sensor position.
Speed Sensor Input Function: Engine speed: Data Valid The TCON will revert to transmission Turbine speed was detected but no engine - Check the can signal containing engine speed
41.01 520316 1 Stop Lamp Solid but Below Normal Operational Range - Most Severe limphome mode. Contact maintenance for troubleshooting speed was measured. (if configured via can)
The value of the engine speed sensor, will
be replaced by an appropriate calculated The measured current in the speed sensor - Check the transmission and speed sensors.
value. circuit is below normal. The input most - Check the speed sensor position.
Speed Sensor Input Function: Engine speed: Current The TCON will revert to transmission likely has a loose connection or it is shorted - Check the can signal containing engine speed
41.05 520316 5 Stop Lamp Solid Below Normal, or Open Circuit limphome mode. Contact maintenance for troubleshooting to battery plus (high source). (if configured via can)

- Check the wiring between the TCON and the


The value of the engine speed sensor, will device connected to this speed input.
be replaced by an appropriate calculated - Check installation and operation of the speed
value. The measured current in the speed sensor sensor connected.
Speed Sensor Input Function: Engine speed: Current The TCON will revert to transmission circuit is above normal. The input is most - refer to the other reported errors to identify
41.06 520316 6 Stop Lamp Solid Above Normal or Grounded Circuit limphome mode. Contact maintenance for troubleshooting likely shorted to ground (low source). the affected speed input.

The value of the engine speed sensor, will - Check if CAN message containing the engine
be replaced by an appropriate calculated speed value is sent correctly on the CAN bus.
value. No engine speed information available, as - Check if the repetition rate of that CAN
Speed Sensor Input Function: Engine speed: Abnormal The TCON will revert to transmission the EEC1 or CVC2TC message is missing on message is fast enough.
41.09 520316 9 Stop Lamp Solid Update Rate limphome mode. Contact maintenance for troubleshooting the CAN bus. - Check CAN connection to the controller.
The value of the engine speed sensor, will
be replaced by an appropriate calculated
value. The contents of the engine speed field in
Speed Sensor Input Function: Engine speed: Received The TCON will revert to transmission the EEC1 or CVC2TC message is set to error - Check engine controller.
41.13 520316 19 Stop Lamp Solid Network Data in Error limphome mode. Contact maintenance for troubleshooting or not available. - Check CAN connection to the controller.

The turbine rpm is 100 rpm above what it


should be. This can be determined using
drum and output speed combined with the
This message is given as additional gear ratios. This check can only be done Check the transmission, in order to understand
Speed Sensor Input Function: Turbine speed: Data Valid information for transmission ratio faults. Contact maintenance for troubleshooting when the turbine is connected to the if and which clutch is slipping. Check the
42.00 520317 0 Amber Warning Solid but Above Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.

The turbine rpm is 100 rpm below what it


should be. This can be determined using
drum and output speed combined with the
This message is given as additional gear ratios. This check can only be done Check the transmission, in order to understand
Speed Sensor Input Function: Turbine speed: Data Valid information for transmission ratio faults. Contact maintenance for troubleshooting when the turbine is connected to the if and which clutch is slipping. Check the
42.01 520317 1 Amber Warning Solid but Below Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.

Speed Sensor Input Function: Turbine speed: Data Contact maintenance for troubleshooting Direction reporting error of the speed - Check the speed sensor
42.02 520317 2 Stop Lamp Solid Erratic, Intermittent, or Incorrect TCON will revert to limphome mode. sensor. - Check the wiring of the speed sensor
- Check the wiring between the TCON and the
turbine speed sensor.
The value of the turbine speed sensor, will The measured current in the speed sensor - Check installation and operation of the speed
be replaced by an appropriate calculated circuit is below normal. The input most sensor connected.
Speed Sensor Input Function: Turbine speed: Current value. Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
42.05 520317 5 Amber Warning Solid Below Normal, or Open Circuit The TCON will disable inching to battery plus (high source). the affected speed input.
- Check the wiring between the TCON and the
turbine speed sensor.
The value of the turbine speed sensor, will - Check installation and operation of the speed
be replaced by an appropriate calculated The measured current in the speed sensor sensor connected.
Speed Sensor Input Function: Turbine speed: Current value. Contact maintenance for troubleshooting circuit is above normal. The input is most - refer to the other reported errors to identify
42.06 520317 6 Amber Warning Solid Above Normal or Grounded Circuit The TCON will disable inching likely shorted to ground (low source). the affected speed input.
The intermediate rpm is 100 rpm above
what it should be. This can be determined
using output and turbine speed combined
Speed Sensor Input Function: intermediate speed: Data This message is given as additional with the gear ratios. To be able to check this Check the transmission, in order to understand
Valid but Above Normal Operational Range - Most information for transmission ratio faults. Contact maintenance for troubleshooting the turbine needs to be connected to the if and which clutch is slipping. Check the
43.00 520318 0 Amber Warning Solid Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
The intermediate rpm is 100 rpm below
what it should be. This can be determined
using output and turbine speed combined
This message is given as additional with the gear ratios. To be able to check this Check the transmission, in order to understand
Speed Sensor Input Function: intermediate speed: Data information for transmission ratio faults. Contact maintenance for troubleshooting the turbine needs to be connected to the if and which clutch is slipping. Check the
43.01 520318 1 Amber Warning Solid Valid but Below Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.
- Check the wiring between the TCON and the
turbine speed sensor.
The measured current in the speed sensor - Check installation and operation of the speed
The value of the intermediate speed sensor, circuit is below normal. The input most sensor connected.
Speed Sensor Input Function: intermediate speed: will be replaced by an appropriate Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
43.05 520318 5 Amber Warning Solid Current Below Normal, or Open Circuit calculated value. to battery plus (high source). the affected speed input.
- Check the wiring between the TCON and the
intermediate speed sensor.
- Check installation and operation of the speed
The value of the intermediate speed sensor, The measured current in the speed sensor sensor connected.
Speed Sensor Input Function: intermediate speed: will be replaced by an appropriate circuit is above normal. The input is most - refer to the other reported errors to identify
43.06 520318 6 Amber Warning Solid Current Above Normal or Grounded Circuit calculated value. Contact maintenance for troubleshooting likely shorted to ground (low source). the affected speed input.
The output rpm is 100 rpm above what it
should be. This can be determined using
drum and turbine speed combined with the
This message is given as additional gear ratios. To be able to check this the Check the transmission, in order to understand
Speed Sensor Input Function: Output speed: Data Valid information for transmission ratio faults. turbine needs to be connected to the if and which clutch is slipping. Check the
44.00 520319 0 Amber Warning Solid but Above Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. Contact maintenance for troubleshooting output. transmission ratio settings of the controller.
The output rpm is 100 rpm below what it
should be. This can be determined using
drum and turbine speed combined with the
This message is given as additional gear ratios. To be able to check this the Check the transmission, in order to understand
Speed Sensor Input Function: Output speed: Data Valid information for transmission ratio faults. turbine needs to be connected to the if and which clutch is slipping. Check the
44.01 520319 1 Amber Warning Solid but Below Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. Contact maintenance for troubleshooting output. transmission ratio settings of the controller.
- Check the wiring between the TCON and the
output speed sensor.
The value of the output speed sensor, will The measured current in the speed sensor - Check installation and operation of the speed
be replaced by an appropriate calculated circuit is below normal. The input most sensor connected.
Speed Sensor Input Function: Output speed: Current value. likely has a loose connection or it is shorted - refer to the other reported errors to identify
44.05 520319 5 Amber Warning Solid Below Normal, or Open Circuit The TCON will disable inching Contact maintenance for troubleshooting to battery plus (high source). the affected speed input.
- Check the wiring between the TCON and the
output speed sensor.
The value of the output speed sensor, will - Check installation and operation of the speed
be replaced by an appropriate calculated The measured current in the speed sensor sensor connected.
Speed Sensor Input Function: Output speed: Current value. circuit is above normal. The input is most - refer to the other reported errors to identify
44.06 520319 6 Amber Warning Solid Above Normal or Grounded Circuit The TCON will disable inching Contact maintenance for troubleshooting likely shorted to ground (low source). the affected speed input.

- check oil level


TCON will revert to shutdown mode. This Transmission Gear Ratio calculated from - check transmission system pressure
will result in inoperability of the vehicle. measured speed signals is above expected - check clutch pressure of all clucthes with
TCON will only resume normal operation value for current gear. different gears engaged
transmission ratio: Data Valid but Above Normal once the error is cleared and TCON is Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.00 520320 0 Stop Lamp Flashing Operational Range - Most Severe restarted. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


TCON will revert to shutdown mode. This Transmission Gear Ratio calculated from - check transmission system pressure
will result in inoperability of the vehicle. measured speed signals is below expected - check clutch pressure of all clucthes with
TCON will only resume normal operation value for current gear. different gears engaged
transmission ratio: Data Valid but Below Normal once the error is cleared and TCON is Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.01 520320 1 Stop Lamp Flashing Operational Range - Most Severe restarted. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


Forward Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is above expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.14 520320 20 Stop Lamp Solid transmission ratio: Forward Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- check oil level


Reverse Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is below expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.15 520320 21 Stop Lamp Solid transmission ratio: Reverse Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


Forward High Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is above expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
transmission ratio: Forward High Clutch Slip - Most standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.16 520320 22 Stop Lamp Solid Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


Stage 1 clutch D Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is below expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.17 520320 23 Stop Lamp Solid transmission ratio: Stage 1 clutch D Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


1st Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is above expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.18 520320 24 Stop Lamp Solid transmission ratio: 1st Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


2nd Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is above expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.19 520320 25 Stop Lamp Solid transmission ratio: 2nd Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


3rd Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is below expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.1A 520320 26 Stop Lamp Solid transmission ratio: 3rd Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


4th Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is below expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.1B 520320 27 Stop Lamp Solid transmission ratio: 4th Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


High Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is above expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.1C 520320 28 Stop Lamp Solid transmission ratio: High Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors

- check oil level


Low Clutch Slip - Most Severe Transmission Gear Ratio calculated from - check transmission system pressure
TCON will revert to limphome mode. measured speed signals is below expected - check clutch pressure of all clucthes with
Transmission will go into neutral untill value for current gear. different gears engaged
standstill. After that, the lowest safe gear Uncontrolled slip in one or more clutches is - check stall speed with different gears engaged
2A.1D 520320 29 Stop Lamp Solid transmission ratio: Low Clutch Slip - Most Severe can be engaged. Contact maintenance for troubleshooting possible. - check speed signals of all speed sensors
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
throttle pedal.
- Check installation and operation of the throttle
TCON will continue normal operation but pedal.
Analog Input Function: Throttle Pedal: Data Valid but the value for the throttle pedal will be Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
2C.00 520321 0 Amber Warning Solid Above Normal Operational Range - Most Severe clipped to the hightest value allowed. Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
throttle pedal.
- Check installation and operation of the throttle
TCON will continue normal operation but pedal.
Analog Input Function: Throttle Pedal: Data Valid but the value for the throttle pedal will be Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
2C.01 520321 1 Amber Warning Solid Below Normal Operational Range - Most Severe clipped to the lowest value allowed. Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
The value of the throttle pedal will be throttle pedal.
replaced by an appropriate default value. - Check installation and operation of the throttle
This will result in reduced vehicle operation, pedal.
Analog Input Function: Throttle Pedal: Voltage Above possibly no shifting or inching will be The input most likely has a loose connection - refer to the other reported errors to identify
2C.03 520321 3 Amber warning Flashing Normal, or Shorted To High Source allowed. Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
The value of the throttle pedal will be throttle pedal.
replaced by an appropriate default value. - Check installation and operation of the throttle
This will result in reduced vehicle operation, pedal.
Analog Input Function: Throttle Pedal: Voltage Below possibly no shifting or inching will be - refer to the other reported errors to identify
2C.04 520321 4 Amber warning Flashing Normal, or Shorted To Low Source allowed. Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input.

The TCON will flag the fault and the TSC1


message will send the idle possition to the
engine controller. The value of the throttle - Check if CAN message containing the throttle
pedal will be replaced by an appropriate pedal value is sent correctly on the CAN bus.
default value. This will result in reduced No throttle pedal information available, as - Check if the repetition rate of that CAN
Analog Input Function: Throttle Pedal: Abnormal Update vehicle operation, possibly no shifting or the EEC2 message is missing on the CAN message is fast enough.
2C.09 520321 9 Amber warning Flashing Rate inching will be allowed. Contact maintenance for troubleshooting bus. - Check CAN connection to the controller.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Throttle Pedal: Data Valid but the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
2C.0F 520321 15 Amber Warning Solid Above Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Throttle Pedal: Data Valid but the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
2C.11 520321 17 Amber Warning Solid Below Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

The TCON will flag the fault and the TSC1


message will send the idle possition to the
engine controller. The value of the throttle
pedal will be replaced by an appropriate The contents of the throttle pedal field in
Analog Input Function: Throttle Pedal: Received Network default value. This will result in reduced the EEC2 message is set to error or not - Check throttle pedal broadcast source.
2C.13 520321 19 Amber warning Flashing Data in Error vehicle operation, possibly no shiftin Contact maintenance for troubleshooting available. - Check CAN connection to the controller.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
throttle pedal.
- Check installation and operation of the throttle
TCON will continue normal operation but pedal.
Analog Input Function: Hydro Lever: Data Valid but the value for the hydro lever will be clipped Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
70.00 520322 0 Amber Warning Solid Above Normal Operational Range - Most Severe to the hightest value allowed. Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
hydro lever.
- Check installation and operation of the hydro
TCON will continue normal operation but lever.
Analog Input Function: Hydro Lever: Data Valid but the value for the hydro lever will be clipped Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
70.01 520322 1 Amber Warning Solid Below Normal Operational Range - Most Severe to the lowest value allowed. Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
The TCON will flag the fault and the value of hydro lever.
the hydro lever will be replaced by an - Check installation and operation of the hydro
appropriate default value. This will result in lever.
Analog Input Function: Hydro Lever: Voltage Above reduced vehicle operation, no engine The input most likely has a loose connection - refer to the other reported errors to identify
70.03 520322 3 Amber warning Flashing Normal, or Shorted To High Source control for hydro lever will be available. Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
The TCON will flag the fault and the value of hydro lever.
the hydro lever will be replaced by an - Check installation and operation of the hydro
appropriate default value. This will result in lever.
Analog Input Function: Hydro Lever: Voltage Below reduced vehicle operation, no engine - refer to the other reported errors to identify
70.04 520322 4 Amber warning Flashing Normal, or Shorted To Low Source control for hydro lever will be available. Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input.

The TCON will flag the fault and the value of - Check if CAN message containing the hydro
the hydro lever will be replaced by an lever value is sent correctly on the CAN bus.
appropriate default value. This will result in No hydro lever information available, as the - Check if the repetition rate of that CAN
Analog Input Function: Hydro Lever: Abnormal Update reduced vehicle operation, no engine required CVC2TC message is missing on the message is fast enough.
70.09 520322 9 Amber warning Flashing Rate control for hydro lever will be available. Contact maintenance for troubleshooting CAN bus. - Check CAN connection to the controller.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Hydro Lever: Data Valid but the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
70.0F 520322 15 Amber Warning Solid Above Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Hydro Lever: Data Valid but the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
70.11 520322 17 Amber Warning Solid Below Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

The TCON will flag the fault and the value of


the hydro lever will be replaced by an
appropriate default value. This will result in The contents of the hydro lever field in the
Analog Input Function: Hydro Lever: Received Network reduced vehicle operation, no engine CVC2TC message is set to error or not - Check hydro lever broadcast source.
70.13 520322 19 Amber warning Flashing Data in Error control for hydro lever will be available. Contact maintenance for troubleshooting available. - Check CAN connection to the controller.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
throttle pedal.
- Check installation and operation of the throttle
TCON will continue normal operation but pedal.
Analog Input Function: Brake Pedal: Data Valid but Above the value for the brake pedal will be clipped Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
71.00 520323 0 Amber Warning Solid Normal Operational Range - Most Severe to the hightest value allowed. Perform a calibration of the connected device. above the maximum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
brake pedal.
- Check installation and operation of the brake
TCON will continue normal operation but pedal.
Analog Input Function: Brake Pedal: Data Valid but Below the value for the brake pedal will be clipped Contact maintenance for troubleshooting or The measured value of the analog input is - refer to the other reported errors to identify
71.01 520323 1 Amber Warning Solid Normal Operational Range - Most Severe to the lowest value allowed. Perform a calibration of the connected device. below the minimum allowed range. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
brake pedal.
The value of the brake pedal will be - Check installation and operation of the brake
replaced by an appropriate default value. pedal.
Analog Input Function: Brake Pedal: Voltage Above This will result in reduced vehicle operation, The input most likely has a loose connection - refer to the other reported errors to identify
71.03 520323 3 Amber warning Flashing Normal, or Shorted To High Source possibly no inching will be allowed. Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input.
- Recalibrate the input, if the problem persists,
check the wiring between the TCON and the
brake pedal.
The value of the brake pedal will be - Check installation and operation of the brake
replaced by an appropriate default value. pedal.
Analog Input Function: Brake Pedal: Voltage Below This will result in reduced vehicle operation, - refer to the other reported errors to identify
71.04 520323 4 Amber warning Flashing Normal, or Shorted To Low Source possibly no inching will be allowed. Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input.

The TCON will flag the fault and the value of - Check if CAN message containing the brake
the brake pedal will be replaced by an pedal value is sent correctly on the CAN bus.
appropriate default value. This will result in No brake pedal information available, as the - Check if the repetition rate of that CAN
Analog Input Function: Brake Pedal: Abnormal Update reduced vehicle operation, possibly no required CVC2TC message is missing on the message is fast enough.
71.09 520323 9 Amber warning Flashing Rate inching will be allowed. Contact maintenance for troubleshooting CAN bus. - Check CAN connection to the controller.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Brake Pedal: Data Valid but Above the highest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
71.0F 520323 15 Amber Warning Solid Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the
connected device.
- refer to the functional error of the attached
TCON will show the error code, and will use device.
Analog Input Function: Brake Pedal: Data Valid but Below the lowest clipped value in its settings for Contact maintenance for troubleshooting - Perform a calibration of the device attached to
71.11 520323 17 Amber Warning Solid Normal Operational Range - Least Severe this analog input. The input is out of calibration. the input.

The TCON will flag the fault and the value of


the brake pedal will be replaced by an
appropriate default value. This will result in The contents of the brake pedal field in the
Analog Input Function: Brake Pedal: Received Network reduced vehicle operation, possibly no CVC2TC message is set to error or not - Check brake pedal broadcast source.
71.13 520323 19 Amber warning Flashing Data in Error inching will be allowed. Contact maintenance for troubleshooting available. - Check CAN connection to the controller.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
- Check the wiring between the TCON and the
sump temperature sensor.
- Check installation and operation of the sump
temperature sensor.
Analog Input Function: Transmission Sump Temperature: The TCON will flag the fault, and take the - refer to the other reported errors to identify
Data Valid but Above Normal Operational Range - Most configured action (either no action, force the configured analogue input.
72.00 520324 0 Amber warning Flashing Severe neutral or reduce engine revs) Contact maintenance for troubleshooting Transmission sump temperature too hot. - Check the operation of the cooler.
- Check the wiring between the TCON and the
sump temperature sensor.
- Check installation and operation of the sump
The TCON will flag the fault and will use a temperature sensor.
Analog Input Function: Transmission Sump Temperature: default value in its settings (which results in The input most likely has a loose connection - refer to the other reported errors to identify
72.03 520324 3 Amber warning Flashing Voltage Above Normal, or Shorted To High Source bad temperature compensation) Contact maintenance for troubleshooting or is shorted to battery plus. the configured analogue input.
- Check the wiring between the TCON and the
sump temperature sensor.
- Check installation and operation of the sump
The TCON will flag the fault and will use a temperature sensor.
Analog Input Function: Transmission Sump Temperature: default value in its settings (which results in - refer to the other reported errors to identify
72.04 520324 4 Amber warning Flashing Voltage Below Normal, or Shorted To Low Source bad temperature compensation) Contact maintenance for troubleshooting The input is most likely shorted to ground. the configured analogue input.
Analog Input function: Transmission Sump out The measured value of the sump
temperature : Data Valid but Above Normal Operational TCON will flag the fault in order to indicate Take notice of the fault, and try to bring the temperature is above the warning level Check the sump temperature and the converter
72.0F 520324 15 Protection Lamp Range - Least Severe the warning level to the driver. sump temperature to a lower level. temperature. out temperature sensor.
Stop the vehicle, select neutral and apply full
throttle (limited to 1500 rpm) in order to cool
The TCON is protecting the transmission the transmission oil until the fault disappears. Check the converter out temperature and the
Analog Input function: Transmission convertor out and does not allow that the converter out Once the converter out temperature is below The measured value of the convertor out converter out temperature sensor.
temperature : Data Valid but Above Normal Operational temperature exceeds its limit. The engine the critical temperature, resume normal temperature is above the critical If operating in dirty environment clean out
2B.00 520325 0 Amber warning Flashing Range - Most Severe will be limited to 1500 rpm. operation. temperature. radiator fins to allow maximum air flow.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the device
Analog Input function: Transmission convertor out The convertor out temperature value will be connected.
temperature : Voltage Above Normal, or Shorted To High replaced by an appropriate default value. The input most likely has a loose connection - refer to the other reported errors to identify
2B.03 520325 3 Amber warning Flashing Source The TCON will continue normal operation. Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input function.

- Check the wiring between the TCON and the


device connected to this analog input.
- Check installation and operation of the device
Analog Input function: Transmission convertor out The convertor out temperature value will be connected.
temperature : Voltage Below Normal, or Shorted To Low replaced by an appropriate default value. - refer to the other reported errors to identify
2B.04 520325 4 Amber warning Flashing Source The TCON will continue normal operation. Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input function.

- replace the filter


TCON will disable inching. Other actions - check the wiring between the TCON and the
depends on parameter setting: - Filter is contaminated filter indicator.
- either TCON will limit the engine speed to - The measured value of the analog input is - Check installation and operation of the filter
a lower value until the filter clogging input above the maximum allowed range. indicator.
Input Function: Filter Clogging: Data Valid but Above becomes inactive. Replace filter or Contact maintenance for - The digital inputs (NO and NC) are both in - refer to the other reported errors to identify
73.00 520326 0 Amber warning Flashing Normal Operational Range - Most Severe - either TCON will take no further action troubleshooting the on state the affected analogue input.

TCON will disable inching. Other actions - check the wiring between the TCON and the
depends on parameter setting: filter indicator.
- either TCON will limit the engine speed to - Check installation and operation of the filter
a lower value until the filter clogging input indicator.
Input Function: Filter Clogging: Voltage Above Normal, or becomes inactive. The input most likely has a loose connection - refer to the other reported errors to identify
73.03 520326 3 Amber warning Flashing Shorted To High Source - either TCON will take no further action Contact maintenance for troubleshooting or is shorted to battery plus. the affected analogue input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will disable inching. Other actions - check the wiring between the TCON and the
depends on parameter setting: filter indicator.
- either TCON will limit the engine speed to - Check installation and operation of the filter
a lower value until the filter clogging input indicator.
Input Function: Filter Clogging: Voltage Below Normal, or becomes inactive. - refer to the other reported errors to identify
73.04 520326 4 Amber warning Flashing Shorted To Low Source - either TCON will take no further action Contact maintenance for troubleshooting The input is most likely shorted to ground. the affected analogue input.

TCON will disable inching. Other actions


depends on parameter setting:
- either TCON will limit the engine speed to The measured value of the analog input is
a lower value until the filter clogging input above the allowed range. This can be a
Input Function: Filter Clogging: Data Valid but Above becomes inactive. normal condition due to cold operating - heat the transmission and check if the fault
73.0F 520326 15 Amber warning Flashing Normal Operational Range - Least Severe - either TCON will take no further action Heat the transmission temperature. code dissapears.
The intermediate rpm is 100 rpm above
what it should be. This can be determined
using output and turbine speed combined
Speed Sensor Input Function: Intermediate 2 speed: Data This message is given as additional with the gear ratios. To be able to check this Check the transmission, in order to understand
Valid but Above Normal Operational Range - Most information for transmission ratio faults. Contact maintenance for troubleshooting the turbine needs to be connected to the if and which clutch is slipping. Check the
74.00 520327 0 Amber Warning Solid Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.
The intermediate rpm is 100 rpm below
what it should be. This can be determined
using output and turbine speed combined
This message is given as additional with the gear ratios. To be able to check this Check the transmission, in order to understand
Speed Sensor Input Function: Intermediate 2 speed: Data information for transmission ratio faults. Contact maintenance for troubleshooting the turbine needs to be connected to the if and which clutch is slipping. Check the
74.01 520327 1 Amber Warning Solid Valid but Below Normal Operational Range - Most Severe The action is taken by ratio fault monitoring. output. transmission ratio settings of the controller.
- Check the wiring between the TCON and the
turbine speed sensor.
The measured current in the speed sensor - Check installation and operation of the speed
The value of the intermediate speed sensor, circuit is below normal. The input most sensor connected.
Speed Sensor Input Function: Intermediate 2 speed: will be replaced by an appropriate Contact maintenance for troubleshooting likely has a loose connection or it is shorted - refer to the other reported errors to identify
74.05 520327 5 Amber Warning Solid Current Below Normal, or Open Circuit calculated value. to battery plus (high source). the affected speed input.
- Check the wiring between the TCON and the
intermediate speed sensor.
- Check installation and operation of the speed
The value of the intermediate speed sensor, The measured current in the speed sensor sensor connected.
Speed Sensor Input Function: Intermediate 2 speed: will be replaced by an appropriate circuit is above normal. The input is most - refer to the other reported errors to identify
74.06 520327 6 Amber Warning Solid Current Above Normal or Grounded Circuit calculated value. Contact maintenance for troubleshooting likely shorted to ground (low source). the affected speed input.

- Check if CAN message containing the


intermediate speed value is sent correctly on
the CAN bus.
The value of the intermediate speed sensor, No intermediate speed information - Check if the repetition rate of that CAN
Speed Sensor Input Function: Intermediate 2 speed: will be replaced by an appropriate available, as the message containing this message is fast enough.
74.09 520327 9 Amber Warning Solid Abnormal Update Rate calculated value. Contact maintenance for troubleshooting information is missing on the CAN bus. - Check CAN connection to the controller.
The value of the intermediate speed sensor, The contents of the intermediate speed
Speed Sensor Input Function: Intermediate 2 speed: will be replaced by an appropriate field in the CAN message is set to error or - Check source of broadcast.
74.13 520327 19 Amber Warning Solid Received Network Data in Error calculated value. Contact maintenance for troubleshooting not available. - Check CAN connection to the controller.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: Clutch Low Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
12.00 520328 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: Clutch Low Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
12.01 520328 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Clutch Low Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
12.03 520328 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Clutch Low Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
12.04 520328 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Clutch Low Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
12.09 520328 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Clutch Low Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
12.13 520328 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

- Check clutch pressure at engine idle when


TCON will revert to shutdown mode. This Measured pressure on this sensor is too clutch is NOT selected (+-0 bar required).
will result in inoperability of the vehicle. high in comparison with the commanded - Check clutch pressure at engine idle when
TCON will only resume normal operation pressure by TCON: clutch is selected.
Input Function: Clutch High Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Proportional solenoid stuck. Log pressure (CAN trace or other measurement
13.00 520329 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

Measured pressure on this sensor is too low - Check oil level.


in comparison with the commanded - Check supply pressure to the transmission at
TCON will revert to shutdown mode. This pressure by TCON: engine idle.
will result in inoperability of the vehicle. - Supply pressure to transmission too low. - Check clutch pressure at engine idle when
TCON will only resume normal operation - Proportional solenoid stuck. clutch is selected.
Input Function: Clutch High Pressure: Data Valid but once the error is cleared and TCON is Contact maintenance for troubleshooting - Oil level too low. Log pressure (CAN trace or other measurement
13.01 520329 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. - Clutch failure equipment) when problem occurs.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Clutch High Pressure: Voltage Above once the error is cleared and TCON is Contact maintenance for troubleshooting The input most likely has a loose connection - refer to the other reported errors to identify
13.03 520329 3 Stop Lamp Flashing Normal, or Shorted To High Source restarted. or is shorted to battery plus. the configured analog input.

- Check the wiring between the TCON and the


TCON will revert to shutdown mode. This pressure sensor connected to this analog input.
will result in inoperability of the vehicle. - Check installation and operation of the
TCON will only resume normal operation connected pressure sensor.
Input Function: Clutch High Pressure: Voltage Below once the error is cleared and TCON is Contact maintenance for troubleshooting - refer to the other reported errors to identify
13.04 520329 4 Stop Lamp Flashing Normal, or Shorted To Low Source restarted. The input is most likely shorted to ground. the configured analog input.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function, Check the source signal from the CAN message
TCON will only resume normal operation received by the corresponding CAN containing the input function for requesting a
Input Function: Clutch High Pressure: Abnormal Update once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable valid value.
13.09 520329 9 Stop Lamp Flashing Rate restarted. value. Check the can bus communication.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. The expected value for the input function
TCON will only resume normal operation received by the corresponding CAN Check the source signal from the CAN message
Input Function: Clutch High Pressure: Received Network once the error is cleared and TCON is Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function for requesting a
13.13 520329 19 Stop Lamp Flashing Data in Error restarted. value. valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This may result in message contains an invalid or unavailable valid value.
79.09 520330 9 Amber warning Flashing Digital Input Function: Declutch: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function declutch will The expected value for the input function
be replaced by the default value. declutch received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Declutch: Received Network Data This will result in reduced operation of the Contact maintenance for troubleshooting message contains an invalid or unavailable containing the input function declutch for
79.13 520330 19 Amber warning Flashing in Error vehicle. value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Automatic Shifting: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
7A.09 520331 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function
Manual/Automatic shifting will be replaced The expected value for the input function Check the source signal from the CAN message
by the default value. Manual/Automatic shifting received by the containing the input function
Digital Input Function: Automatic Shifting: Received This will result in reduced operation of the Contact maintenance for troubleshooting corresponding CAN message contains an Manual/Automatic shifting for requesting a valid
7A.13 520331 19 Amber warning Flashing Network Data in Error vehicle. invalid or unavailable value. value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Inching Enable: Abnormal Update appropriate default value. This may result in message contains an invalid or unavailable valid value.
7B.09 520332 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Inching The expected value for the input function
enable will be replaced by the default value. Inching enable received by the Check the source signal from the CAN message
Digital Input Function: Inching Enable: Received Network This will result in reduced operation of the Contact maintenance for troubleshooting corresponding CAN message contains an containing the input function Inching enable for
7B.13 520332 19 Amber warning Flashing Data in Error vehicle. invalid or unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Parking Brake: Abnormal Update appropriate default value. This may result in message contains an invalid or unavailable valid value.
7C.09 520333 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Parking The expected value for the input function
Brake will be replaced by the default value. Parking Brake received by the Check the source signal from the CAN message
Digital Input Function: Parking Brake: Received Network This will result in reduced operation of the Contact maintenance for troubleshooting corresponding CAN message contains an containing the input function Parking Brake for
7C.13 520333 19 Amber warning Flashing Data in Error vehicle. invalid or unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Seat Orientation: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
7D.09 520334 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will continue normal operation, but
the value of the input function Seat
Orientation will be replaced by the default The expected value for the input function
value. Seat Orientation received by the Check the source signal from the CAN message
Digital Input Function: Seat Orientation: Received This will result in reduced operation of the Contact maintenance for troubleshooting corresponding CAN message contains an containing the input function Seat Orientation
7D.13 520334 19 Amber warning Flashing Network Data in Error vehicle. invalid or unavailable value. for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Reduced vehicle speed: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
7E.09 520335 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function Reduced
vehicle speed will be replaced by the The expected value for the input function
default value. Reduced vehicle speed received by the Check the source signal from the CAN message
Digital Input Function: Reduced vehicle speed: Received This will result in reduced operation of the corresponding CAN message contains an containing the input function Reduced vehicle
7E.13 520335 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. speed for requesting a valid value.
Digital Input Function: Redundant Vehicle reduced
7F.09 520336 9 Amber warning Flashing speed: Abnormal Update Rate

TCON will continue normal operation, but


the value of the input function Redundant
Reduced Vehicle speed will be replaced by The expected value for the input function Check the source signal from the CAN message
the default value. Redundant Reduced Vehicle speed received containing the input function Redundant
Digital Input Function: Redundant Reduced Vehicle This will result in reduced operation of the by the corresponding CAN message Reduced Vehicle speed for requesting a valid
7F.13 520336 19 Amber warning Flashing speed: Received Network Data in Error vehicle. Contact maintenance for troubleshooting contains an invalid or unavailable value. value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Start 1st/2nd: Abnormal Update appropriate default value. This may result in message contains an invalid or unavailable valid value.
80.09 520337 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function Start
1st/2nd will be replaced by the default The expected value for the input function
value. Start 1st/2nd received by the corresponding Check the source signal from the CAN message
Digital Input Function: Start 1st/2nd: Received Network This will result in reduced operation of the CAN message contains an invalid or containing the input function Start 1st/2nd for
80.13 520337 19 Amber warning Flashing Data in Error vehicle. Contact maintenance for troubleshooting unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Operator Seated: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
81.09 520338 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Operator The expected value for the input function
Seated will be replaced by the default value. Operator Seated received by the Check the source signal from the CAN message
Digital Input Function: Operator Seated: Received This will result in reduced operation of the corresponding CAN message contains an containing the input function Operator Seated
81.13 520338 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: 4WD/2WD feedback loop: appropriate default value. This may result in message contains an invalid or unavailable valid value.
26.09 520339 9 Amber warning Flashing Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function 4WD/2WD
will be replaced by the default value. Check the source signal from the CAN message
Digital Input Function: 4WD/2WD: Data Valid but Below This will result in reduced operation of the The feedback shows 2WD but 4WD output containing the input function 4WD/2WD for
26.11 520339 17 Amber warning Flashing Normal Operational Range - Least Severe vehicle. Contact maintenance for troubleshooting is activated requesting a valid value.

The TCON will flag the fault and the state of Check the source signal from the CAN message
the function will be replaced by an containing the input function for requesting a
Digital Input Function: 4WD/2WD: Data Valid but Above appropriate default value. This may result in The feedback shows 4WD but 2WD output valid value.
26.0F 520339 15 Amber warning Flashing Normal Operational Range - Least Severe reduced vehicle operation. Contact maintenance for troubleshooting is activated Check the can bus communication.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will continue normal operation, but
the value of the input function 4WD/2WD
feedback loop will be replaced by the The expected value for the input function
default value. 4WD/2WD feedback loop received by the Check the source signal from the CAN message
Digital Input Function: 4WD/2WD feedback loop: This will result in reduced operation of the corresponding CAN message contains an containing the input function 4WD/2WD
26.13 520339 19 Amber warning Flashing Received Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. feedback loop for requesting a valid value.

The TCON will flag the fault and the state of


Digital Input Function: Low/High Range selection the function will be replaced by an Check the source signal from the input function
feedback loop: Data Valid but Above Normal Operational appropriate default value. This may result in The feedbacks shows high range but the low for requesting a valid value.
27.00 520341 0 Amber warning Flashing Range - Most Severe reduced vehicle operation. Contact maintenance for troubleshooting output is activated Check the can bus communication.

The TCON will flag the fault and the state of


Digital Input Function: Low/High Range selection the function will be replaced by an Check the source signal from the input function
feedback loop: Data Valid but Below Normal Operational appropriate default value. This may result in The feedbacks shows low range but the high for requesting a valid value.
27.01 520341 1 Amber warning Flashing Range - Most Severe reduced vehicle operation. Contact maintenance for troubleshooting output is activated Check the can bus communication.

The TCON will flag the fault and the state of


the function will be replaced by an Check the source signal from the input function
Digital Input Function: Low/High Range selection appropriate default value. This may result in The expected value for the input function, for requesting a valid value.
27.02 520341 2 Amber warning Flashing feedback loop: Data Erratic, Intermittent, or Incorrect reduced vehicle operation. Contact maintenance for troubleshooting contains an invalid or unavailable value. Check the can bus communication.

The TCON will flag the fault and the state of


Digital Input Function: Low/High Range selection the function will be replaced by an The feedback shows a position or request Check the source signal from the input function
feedback loop: Data Valid but Above Normal Operational appropriate default value. This may result in for neutral and the corresponding state is for requesting a valid value.
27.0F 520341 15 Amber warning Flashing Range - Least Severe reduced vehicle operation. Contact maintenance for troubleshooting higher Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Low/High
Range selection feedback loop will be The expected value for the input function Check the source signal from the CAN message
replaced by the default value. Low/High Range selection received by the containing the input function Low/High Range
Digital Input Function: Low/High Range selection This will result in reduced operation of the corresponding CAN message contains an selection feedback loop for requesting a valid
27.13 520341 19 Amber warning Flashing feedback loop: Received Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. value.

TCON will continue normal operation, but


the value of the input function Lockup The expected value for the input function, Check the source signal from the CAN message
Enable will be replaced by the default value. received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Lockup Enable: Abnormal Update This will result in reduced operation of the message contains an invalid or unavailable valid value.
86.09 520343 9 Amber warning Flashing Rate vehicle. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Lockup The expected value for the input function
Enable will be replaced by the default value. Lockup Enable received by the Check the source signal from the CAN message
Digital Input Function: Lockup Enable: Received Network This will result in reduced operation of the corresponding CAN message contains an containing the input function Lockup Enable for
86.13 520343 19 Amber warning Flashing Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This may result in message contains an invalid or unavailable valid value.
87.09 520344 9 Amber warning Flashing Digital Input Function: Exhaust: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Exhaust will The expected value for the input function
be replaced by the default value. Exhaust received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Exhaust: Received Network Data This will result in reduced operation of the message contains an invalid or unavailable containing the input function Exhaust for
87.13 520344 19 Amber warning Flashing in Error vehicle. Contact maintenance for troubleshooting value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This will make message contains an invalid or unavailable valid value.
88.09 520345 9 Amber warning Flashing Digital Input Function: Retarder: Abnormal Update Rate the retarder functionality unavailable. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

The TCON will flag the fault and the state of The expected value for the input function
the function will be replaced by an Retarder received by the corresponding Check the source signal from the CAN message
Digital Input Function: Retarder: Received Network Data appropriate default value. This will make CAN message contains an invalid or containing the input function Retarder for
88.13 520345 19 Amber warning Flashing in Error the retarder functionality unavailable. Contact maintenance for troubleshooting unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This may result in message contains an invalid or unavailable valid value.
89.09 520346 9 Amber warning Flashing Digital Input Function: Towing: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Towing will The expected value for the input function
be replaced by the default value. Towing received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Towing: Received Network Data in This will result in reduced operation of the message contains an invalid or unavailable containing the input function Towing for
89.13 520346 19 Amber warning Flashing Error vehicle. Contact maintenance for troubleshooting value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Towing Feedback 1: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
8A.09 520347 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function Towing
Feedback 1 will be replaced by the default The expected value for the input function
value. Towing Feedback 1 received by the Check the source signal from the CAN message
Digital Input Function: Towing Feedback 1: Received This will result in reduced operation of the corresponding CAN message contains an containing the input function Towing Feedback
8A.13 520347 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. 1 for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Towing Feedback 2: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
8B.09 520348 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function Towing
Feedback 2 will be replaced by the default The expected value for the input function
value. Towing Feedback 2 received by the Check the source signal from the CAN message
Digital Input Function: Towing Feedback 2: Received This will result in reduced operation of the corresponding CAN message contains an containing the input function Towing Feedback
8B.13 520348 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. 2 for requesting a valid value.

The expected value for the input function,


The value of the shiftlever function will be received by the corresponding CAN
Digital Input Function: Redundant neutral: Data Erratic, overrruled by neutral selection. TCON will Stop the vehicle and contact maintenance for message or digital input contains an invalid Check the shift lever signals
8C.02 520349 2 Stop Lamp Flashing Intermittent, or Incorrect revert to shutdown mode. troubleshooting or unavailable value. Check the redundant neutral signal.

The expected value for the input function, Check the source signal from the CAN message
The value of the shiftlever function will be received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Redundant neutral: Abnormal overrruled by neutral selection. TCON will Stop the vehicle and contact maintenance for message contains an invalid or unavailable valid value.
8C.09 520349 9 Stop Lamp Flashing Update Rate revert to shutdown mode. troubleshooting value. Check the can bus communication.

The expected value for the input function


The value of the shiftlever function will be Redundant Neutral received by the Check the source signal from the CAN message
Digital Input Function: Redundant neutral: Received overrruled by neutral selection. TCON will Stop the vehicle and contact maintenance for corresponding CAN message contains an containing the input function Redundant
8C.13 520349 19 Stop Lamp Flashing network dara in Error revert to shutdown mode. troubleshooting invalid or unavailable value. Neutral for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This may result in message contains an invalid or unavailable valid value.
8D.09 520350 9 Amber warning Flashing Digital Input Function: Eco Mode: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function "Eco Mode" The expected value for the input function
will be replaced by the default value. "Eco Mode" received by the corresponding Check the source signal from the CAN message
Digital Input Function: Eco Mode: Received Network Data This will result in reduced operation of the CAN message contains an invalid or containing the input function Eco Mode for
8D.13 520350 19 Amber warning Flashing in Error vehicle. Contact maintenance for troubleshooting unavailable value. requesting a valid value.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Enhanced vehicle speed appropriate default value. This may result in message contains an invalid or unavailable valid value.
8E.09 520351 9 Amber warning Flashing resolution: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function "Enhanced The expected value for the input function
vehicle speed resolution" will be replaced "Enhanced vehicle speed resolution"
by the default value. received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Enhanced vehicle speed This will result in reduced operation of the message contains an invalid or unavailable containing the input function Enhanced vehicle
8E.13 520351 19 Amber warning Flashing resolution: Received Network Data in Error vehicle. Contact maintenance for troubleshooting value. speed resolution for requesting a valid value.
- download a valid and compatible firmware file
During intialization the TCON detected that (XML file) with the correct corresponding DANA
the firmware present is not compatible with tool.
this TCON. - if the problem persists, the program and/or
Configuration Error: Incompatible Firmware: Failure TCON is stuck in shutdown mode until this is dataflash in the TCON is defective: replace the
5A.0C 520352 12 Stop Lamp Flashing Condition Exists TCON will revert to TCON shutdown mode Contact maintenance for troubleshooting. solved TCON.

A controlled power down of the TCON should


be performed. If the error still persists, activate
a working APT with the appropriate Dana tool,
During intialization the TCON detected that and perform a controlled power down again. If
the flashsector 0 and/or 1 definitions-check the error still persists, the TCON is probably
Perform controlled power down and restart the does not correspond with what is expected. damaged : replace the TCON. Refer to the other
Configuration Error: Incompatible Data File: Failure Refer to the other reported errors to get vehicle. If the problem persists, contact This might be due to a firmware upgrade. reported errors to get more information about
5A.1F 520352 31 Stop Lamp Flashing Condition Exists more information about the TCON action. maintenance for troubleshooting. the nature of the problem.

The TCON will flag the fault and the state of The expected value for the input function Check the source signal from the CAN message
the function will be replaced by an "Loader Mode", received by the containing the input function for requesting a
Digital Input Function: Loader Mode: Abnormal Update appropriate default value. This may result in corresponding CAN message contains an valid value.
8F.09 520354 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting invalid or unavailable value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function "Loader The expected value for the input function
Mode" will be replaced by the default value. "Loader Mode" received by the Check the source signal from the CAN message
Digital Input Function: Loader Mode Received Network This will result in reduced operation of the corresponding CAN message contains an containing the input function Exhaust for
8F.13 520354 19 Amber warning Flashing Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function Check the source signal from the CAN message
the function will be replaced by an "Kickdown", received by the corresponding containing the input function for requesting a
appropriate default value. This may result in CAN message contains an invalid or valid value.
90.09 520355 9 Amber warning Flashing Digital Input Function: Kickdown Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting unavailable value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function "Kickdown" The expected value for the input function
will be replaced by the default value. "Kickdown" received by the corresponding Check the source signal from the CAN message
Digital Input Function: Kickdown Received Network Data This will result in reduced operation of the CAN message contains an invalid or containing the input function "Kickdown" for
90.13 520355 19 Amber warning Flashing in Error vehicle. Contact maintenance for troubleshooting unavailable value. requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Inching Mode Selection Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
91.09 520356 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON will continue normal operation, but
the value of the input function "Inching
Mode Select" will be replaced by the default The expected value for the input function
value. "Inching mode select" received by the Check the source signal from the CAN message
Digital Input Function: Inching Mode Selection Received This will result in reduced operation of the corresponding CAN message contains an containing the input function "inching mode
91.13 520356 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. select" for requesting a valid value.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: declutch enable/disable Selection appropriate default value. This may result in message contains an invalid or unavailable valid value.
92.09 520357 9 Amber warning Flashing Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function will be The expected value for the input function
replaced by the default value. received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Declutch enable/disable Selection This will result in reduced operation of the message contains an invalid or unavailable containing the input function for requesting a
92.13 520357 19 Amber warning Flashing Received Network Data in Error vehicle. Contact maintenance for troubleshooting value. valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Inhibit Upshift: Abnormal Update appropriate default value. This may result in message contains an invalid or unavailable valid value.
93.09 520358 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function will be The expected value for the input function
replaced by the default value. received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Inhibit Upshift: Received Network This will result in reduced operation of the message contains an invalid or unavailable containing the input function for requesting a
93.13 520358 19 Amber warning Flashing Data in Error vehicle. Contact maintenance for troubleshooting value. valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Neutral Lock: Abnormal Update appropriate default value. This may result in message contains an invalid or unavailable valid value.
82.09 520359 9 Amber warning Flashing Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Operator The expected value for the input function
Seated will be replaced by the default value. Operator Seated received by the Check the source signal from the CAN message
Digital Input Function: Neutral Lock: Received Network This will result in reduced operation of the corresponding CAN message contains an containing the input function Operator Seated
82.13 520359 19 Amber warning Flashing Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
appropriate default value. This may result in message contains an invalid or unavailable valid value.
83.09 520360 9 Amber warning Flashing Digital Input Function: New Idle: Abnormal Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function Operator The expected value for the input function
Seated will be replaced by the default value. Operator Seated received by the Check the source signal from the CAN message
Digital Input Function: New Idle: Received Network Data This will result in reduced operation of the corresponding CAN message contains an containing the input function Operator Seated
83.13 520360 19 Amber warning Flashing in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. for requesting a valid value.

The TCON will flag the fault and the state of The expected value for the input function, Check the source signal from the CAN message
the function will be replaced by an received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Upshift Command: Abnormal appropriate default value. This may result in message contains an invalid or unavailable valid value.
60.09 520363 9 Amber warning Flashing Update Rate reduced vehicle operation. Contact maintenance for troubleshooting value. Check the can bus communication.

TCON will continue normal operation, but


the value of the input function "Eco Mode" The expected value for the input function
will be replaced by the default value. "Upshift Command" received by the Check the source signal from the CAN message
Digital Input Function: Upshift Command: Received This will result in reduced operation of the corresponding CAN message contains an containing the input functionUpshift Command
60.13 520363 19 Amber warning Flashing Network Data in Error vehicle. Contact maintenance for troubleshooting invalid or unavailable value. for requesting a valid value.

The expected value for the input function, Check the source signal from the CAN message
received by the corresponding CAN containing the input function for requesting a
Digital Input Function: Motor status bit: Abnormal TCON will revert to transmission shutdown message contains an invalid or unavailable valid value.
61.09 520364 9 Stop Lamp Flashing Update Rate mode. Contact maintenance for troubleshooting value. Check the can bus communication.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

The expected value for the input function


received by the corresponding CAN Check the source signal from the CAN message
Digital Input Function: Motor status bit: Received TCON will revert to transmission shutdown message contains an invalid or unavailable containing the input functionUpshift Command
61.13 520364 19 Stop Lamp Flashing Network Data in Error mode. Contact maintenance for troubleshooting value. for requesting a valid value.

Power supply to the controller too high:


Supply power for controller: Data Valid but Above APC300 12V supply version: > 18 V - Check power supply
1E.00 520368 0 Stop Lamp Flashing Normal Operational Range - Most Severe TCON will revert to recovery mode. Contact maintenance for troubleshooting APC300 24V supply version: > 32 V - Check if a jump start setup is still connected.
- Check power supply to the controller.
- Check alternator
- Check the connection cables between the
Supply power for controller: Data Valid but Below Power supply to the controller too low battery and the alternator
1E.01 520368 1 Stop Lamp Flashing Normal Operational Range - Most Severe TCON will revert to recovery mode. Contact maintenance for troubleshooting (<10V) - Check the battery.
- Check power supply to the controller.
- Check alternator
- Check the connection cables between the
Supply power for controller: Data Valid but Above Power supply to the controller too high, but battery and the alternator
1E.0F 520368 15 Amber Warning Solid Normal Operational Range - Least Severe TCON will continue normal operation. Contact maintenance for troubleshooting not affecting normal operation - Check the battery.
- Check power supply to the controller.
- Check alternator
- Check the connection cables between the
Supply power for controller: Data Valid but Below Power supply to the controller too low, but battery and the alternator
1E.11 520368 17 Amber Warning Solid Normal Operational Range - Least Severe TCON will continue normal operation. Contact maintenance for troubleshooting not affecting normal operation - Check the battery.
- Check power supply.
- check speed sensor connections
Supply power for sensors 8V: Data Valid but Above TCON will revert to transmission limphome APC Internal voltage supply for the speed - Send back controller for troubleshooting to
1F.00 520369 0 Stop Lamp Solid Normal Operational Range - Most Severe mode. Contact maintenance for troubleshooting sensors : Vsense (8V) is below 7,2 V Dana Belgium N.V.
- Check power supply.
- check speed sensor connections
Supply power for sensors 8V: Data Valid but Below TCON will revert to transmission limphome APC Internal voltage supply for the speed - Send back controller for troubleshooting to
1F.01 520369 1 Stop Lamp Solid Normal Operational Range - Most Severe mode. Contact maintenance for troubleshooting sensors : Vsense (8V) is above 8,8 V Dana Belgium N.V.

APC Internal Sensor Reference exceeded - Check power supply.


the alarm limit. - check connected sensors to the 5V supply
Supply power for sensors 5V: Data Valid but Above TCON will revert to transmission shutdown Correct measurement of TCON.L input - Send back controller for troubleshooting to
77.00 520370 0 Stop Lamp Flashing Normal Operational Range - Most Severe mode. Contact maintenance for troubleshooting signals can not be guaranteed anymore. Dana Belgium N.V.

APC Internal Sensor Reference exceeded - Check power supply.


the alarm limit. - check connected sensors to the 5V supply
Supply power for sensors 5V: Data Valid but Below TCON will revert to transmission shutdown Correct measurement of TCON.L input - Send back controller for troubleshooting to
77.01 520370 1 Stop Lamp Flashing Normal Operational Range - Most Severe mode. Contact maintenance for troubleshooting signals can not be guaranteed anymore. Dana Belgium N.V.

APC Sensor Reference ground faulty.


Ground sense fault: Current Below Normal, or Open TCON will revert to transmission shutdown Correct measurement of TCON input signals Check ground pins, make sure ground sense is
76.05 520372 5 Stop Lamp Flashing Circuit mode. Contact maintenance for troubleshooting can not be guaranteed anymore. wired correctly.
- Check the wiring between the controller and
redundant shutdown path sensors (RSP): Failure TCON will revert to transmission limphome the speed sensors.
22.1F 520379 31 Stop Lamp Flashing Condition Exists mode. Contact maintenance for troubleshooting One or more speed channel failures - Check the speed sensors,

TCON will revert to shutdown mode. This - Check the wiring between the controller and
will result in inoperability of the vehicle. the speed sensors.
TCON will only resume normal operation - Check the speed sensors.
redundant shutdown path turbine (RSP): Data Valid but once the error is cleared and TCON is Stop the vehicle and contact maintenance for Speed sensor failure, - Check the speed sensor positions.
22.01 520379 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. troubleshooting Supply pressure to transmission too low - Check supply pressure to the transmission.
TCON will revert to shutdown mode. This
will result in inoperability of the vehicle. - Check the wiring between the controller and
TCON will only resume normal operation Speed sensor failure, the speed sensors.
redundant shutdown path drum (RSP): Data Valid but once the error is cleared and TCON is Stop the vehicle and contact maintenance for Too much drag because of thick oil, - Check the speed sensors.
22.00 520379 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. troubleshooting Sticking or burnt clutch - Check the speed sensor positions.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the wiring between the controller and


TCON will revert to shutdown mode. This the speed sensors.
will result in inoperability of the vehicle. - Check the speed sensors.
TCON will only resume normal operation Speed sensor failure, RSP drive solenoid - Check the speed sensor positions.
redundant shutdown path pressure (RSP): Data Valid but once the error is cleared and TCON is Stop the vehicle and contact maintenance for failure. - Check supply pressure to the transmission,
22.00 520379 0 Stop Lamp Flashing Above Normal Operational Range - Most Severe restarted. troubleshooting Supply pressure to transmission too low - Check the RSP drive solenoid.
TCON will revert to shutdown mode. This - Check the wiring between the controller and
will result in inoperability of the vehicle. Speed sensor failure, RSP drive solenoid the speed sensors.
TCON will only resume normal operation failure. - Check the speed sensors.
redundant shutdown path pressure (RSP): Data Valid but once the error is cleared and TCON is Stop the vehicle and contact maintenance for Too much drag because of thick oil, - Check the speed sensor positions.
22.01 520379 1 Stop Lamp Flashing Below Normal Operational Range - Most Severe restarted. troubleshooting Sticking or burnt clutch - Check the RSP drive solenoid.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C1.09 520385 9 Amber warning Flashing Can Message CVC_to_TC_1: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C2.09 520386 9 Amber warning Flashing Can Message CVC_to_TC_2: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C3.09 520387 9 Amber warning Flashing Can Message CVC_to_TC_6: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C4.09 520388 9 Amber warning Flashing Can Message CVC_to_TC_4: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C5.09 520389 9 Amber warning Flashing Can Message CVC_to_TC_5: Abnormal Update Rate expected timeframe. message is fast enough.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C6.09 520390 9 Amber warning Flashing Can Message EEC1: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


all the input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C7.09 520391 9 Amber warning Flashing Can Message EEC2: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but all the
input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C8.09 520392 9 Amber warning Flashing Can Message TC1: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but all the
input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
C9.09 520393 9 Amber warning Flashing Can Message CCVS1: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but all the
input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CA.09 520394 9 Amber warning Flashing Can Message ERC1: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but all the
input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CB.09 520395 9 Amber warning Flashing Can Message SSI: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but all the
input functions contained in this CAN
message will not be available.
Refer to the other reported errors to see
which functions are missing. These will - Check if the CAN message is sent correctly on
determine the appropriate action taken by the CAN bus.
the TCON. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CC.09 520396 9 Amber warning Flashing Can Message EPD: Abnormal Update Rate expected timeframe. message is fast enough.
TCON will continue operation, but the oil
level measurement request will not be - Check if the CAN message is sent correctly on
available. the CAN bus.
Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CD.09 520397 9 Amber warning Flashing Can Message CM3: Abnormal Update Rate expected timeframe. message is fast enough.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI
TCON will revert to shutdown. As this
message contains critical data, the vehicle - Check if the CAN message is sent correctly on
cannot be driven until the message the CAN bus.
becomes available again. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CE.09 520398 9 Stop Lamp Flashing Can Message EM_to_TC_1: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will revert to shutdown, as the


auxiliary motor speed is a critical signal. The - Check if the CAN message is sent correctly on
vehicle cannot be driven until the message the CAN bus.
becomes available again. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
CF.09 520399 9 Stop Lamp Flashing Can Message AUXEM_to_TC_1: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact At fill area calibration, timeout on full
D0.00 520400 0 Amber warning Flashing reach a minimum value. for this clutch will have failed maintenance for troubleshooting turbine pulldown.

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase
D0.02 520400 2 Amber warning Flashing Transmission failure during calibration. for this clutch will have failed restart controller and check error reporting. Transmission error detected restart controller and check error reporting.

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase retry calibration, if still not successfull contact
D0.07 520400 7 Amber warning Flashing At start of P2mA, the pressure signal is too high. for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase retry calibration, if still not successfull contact
D0.08 520400 8 Amber warning Flashing Measured pressure points do not allow interpolation. for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can
During P2mA routine a pressure drop of more than 1 bar continue after this command, but this phase retry calibration, if still not successfull contact
D0.0C 520400 12 Amber warning Flashing is detected. for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact
D0.10 520400 16 Amber warning Flashing decrease. for this clutch will have failed maintenance for troubleshooting Turbine speed doesn't decrease

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase retry calibration, if still not successfull contact
D0.11 520400 17 Amber warning Flashing Pressure range for P2mA is too small. (< 2 bar) for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can fill area calibration, at start of filling of
during calibration the turbine speed signal is too low to continue after this command, but this phase retry calibration, if still not successfull contact clutch, the turbine speed is below
D0.12 520400 18 Amber warning Flashing start calibration. for this clutch will have failed maintenance for troubleshooting parameter "Fill-TPD<SPD".

TCON will hold calibration until the continue


command is issued. Calibration can
maximum number of retries reached during P2mA for continue after this command, but this phase retry calibration, if still not successfull contact
D0.1F 520400 31 Amber warning Flashing the peak to peak pressure. for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact At fill area calibration, timeout on full
D1.00 520401 0 Amber warning Flashing reach a minimum value. for this clutch will have failed maintenance for troubleshooting turbine pulldown.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will hold calibration until the continue


command is issued. Calibration can
Turbine speed signal does not reach a high enough value continue after this command, but this phase retry calibration, if still not successfull contact turbine speed <= 5 rpm at end of release
D1.01 520401 1 Amber warning Flashing during release phase of the touch pressure calibration. for this clutch will have failed maintenance for troubleshooting phase

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase
D1.02 520401 2 Amber warning Flashing Transmission failure during calibration. for this clutch will have failed restart controller and check error reporting. Transmission error detected restart controller and check error reporting.

TCON will hold calibration until the continue


command is issued. Calibration can
Turbine speed does not reach value = 0 rpm at end of continue after this command, but this phase retry calibration, if still not successfull contact during touch pressure when at full pressure,
D1.07 520401 7 Amber warning Flashing closing phase of the touch pressure calibration for this clutch will have failed maintenance for troubleshooting the turbine speed > 5 rpm.

TCON will hold calibration until the continue


command is issued. Calibration can timeout on detection of touch. ( measured
continue after this command, but this phase retry calibration, if still not successfull contact torque > (drag torque + parameter
D1.0B 520401 11 Amber warning Flashing No touch detection. for this clutch will have failed maintenance for troubleshooting TouchTorq))

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact
D1.10 520401 16 Amber warning Flashing decrease. for this clutch will have failed maintenance for troubleshooting Turbine speed doesn't decrease

TCON will hold calibration until the continue


command is issued. Calibration can fill area calibration, at start of filling of
during calibration the turbine speed signal is too low to continue after this command, but this phase retry calibration, if still not successfull contact clutch, the turbine speed is below
D1.12 520401 18 Amber warning Flashing start calibration. for this clutch will have failed maintenance for troubleshooting parameter "Fill-TPD<SPD".

After filling phase and 2 seconds wait, the


TCON will hold calibration until the continue measured torque is bigger than parameter
command is issued. Calibration can "DragTorqMax" or is bigger than parameter
continue after this command, but this phase retry calibration, if still not successfull contact "TouchTorq". (if TouchTorq is bigger than 0.
D1.1F 520401 31 Amber warning Flashing Early touch detection. Too much drag. for this clutch will have failed maintenance for troubleshooting This is set to zero for TE30)

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact At fill area calibration, timeout on full
D2.00 520402 0 Amber warning Flashing reach a minimum value. for this clutch will have failed maintenance for troubleshooting turbine pulldown.

TCON will hold calibration until the continue


command is issued. Calibration can
continue after this command, but this phase
D2.02 520402 2 Amber warning Flashing Transmission failure during calibration. for this clutch will have failed restart controller and check error reporting. Transmission error detected restart controller and check error reporting.

TCON will hold calibration until the continue


command is issued. Calibration can
At start of fill area calibration, there's a timeout on continue after this command, but this phase retry calibration, if still not successfull contact
D2.07 520402 7 Amber warning Flashing closing the clutch in the other stage. for this clutch will have failed maintenance for troubleshooting

TCON will hold calibration until the continue


command is issued. Calibration can
During calibration the turbine speed signal does not continue after this command, but this phase retry calibration, if still not successfull contact Turbine speed doesn't decrease to start
D2.10 520402 16 Amber warning Flashing decrease. for this clutch will have failed maintenance for troubleshooting with turbine pulldown detection.

TCON will hold calibration until the continue


command is issued. Calibration can fill area calibration, at start of filling of
during calibration the turbine speed signal is too low to continue after this command, but this phase retry calibration, if still not successfull contact clutch, the turbine speed is below
D2.12 520402 18 Amber warning Flashing start calibration. for this clutch will have failed maintenance for troubleshooting parameter "Fill-TPD<SPD".
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

TCON will revert to restricted mode until


the message becomes available. The electro
motor ready state is defaulted to "not - Check if the CAN message is sent correctly on
ready" and this means error reporting is put the CAN bus.
on hold and no driving is possible. Contact maintenance for troubleshooting The CAN message is not received within the - Check if the repetition rate of the CAN
DA.09 520410 9 Amber warning Flashing Can Message Em_Ready: Abnormal Update Rate expected timeframe. message is fast enough.

TCON will continue normal operation, but


the calibration values of the transmission The transmission calibration in the TCON
will be replaced by the default values. has not been performed yet. The
Exceed Transmission Calibration Interval: Out of This may result in reduced performance Perform a transmission calibration or corresponding exceed code is reported to
E5.0D 520416 13 Amber Warning Solid Calibration quality of the vehicle. Contact maintenance for troubleshooting. indicate this situation to the driver. Perform a transmission calibration.

TCON will continue normal operation, but


the calibration values of the transmission The transmission calibration in the TCON
are not up to date. has not been performed yet or has expired.
Exceed Transmission Calibration Interval: Data Valid but This may result in reduced performance The corresponding exceed code is reported
E5.0F 520416 15 Amber Warning Solid Above Normal Operational Range - Least Severe quality of the vehicle. Perform a transmission calibration. to indicate this situation to the driver. Perform a transmission calibration.

An operational limit was exceeded during


No special action taken by the TCON. normal operation. The corresponding
Exceed Downshift Vehicle Speed: Data Valid but Above Normal application logics are active to Slow down the vehicle to decrease the speed exceed code is reported to indicate this
E0.0F 520417 15 Protection Lamp Normal Operational Range - Least Severe handle the situation. until the requested downshift is allowed. situation to the driver. none

An operational limit was exceeded during


No special action taken by the TCON. normal operation. The corresponding
Exceed Direction Change Vehicle Speed: Data Valid but Normal application logics are active to Slow down the vehicle to decrease the speed exceed code is reported to indicate this
E1.0F 520418 15 Protection Lamp Above Normal Operational Range - Least Severe handle the situation. until the requested direction change is allowed. situation to the driver. none

An operational limit was exceeded during


No special action taken by the TCON. normal operation. The corresponding
Exceed Direction Change Engine Speed: Data Valid but Normal application logics are active to Lower the engine speed until the requested exceed code is reported to indicate this
E2.0F 520419 15 Protection Lamp Above Normal Operational Range - Least Severe handle the situation. direction change is allowed. situation to the driver. none
TCON is limiting the vehicle speed to the set
vehicle speed limit. Speed is within 85%-
105% range of set speed limit. (the 85% is a
Exceed Reduced vehicle speed : Data Valid but Above configurable, and may deviate on some No action is requested, the vehicle speed is
E3.0F 520420 15 Protection Lamp Normal Operational Range - Least Severe applications) limited due to request. The vehicle speed limitation is active. none

TCON is limiting the vehicle speed to the Slow down the vehicle, until that the vehicle
Exceed Reduced vehicle speed : Data Valid but Above maximum or reduced vehicle speed limit, speed comes below the maximum or reduced The vehicle speed is above the maximum
E3.10 520420 16 Protection Lamp Normal Operational Range - Moderately Severe but detects a higher vehicle speed. vehicle speed limit. vehicle speed limit. none
The controller detected an abnormal
accelleration, and will disable the
Exceed Abnormal Accelaration/Deceleration: Data Valid The driver should slow down the engine, in automatiic shifting for a certain time.
E4.0F 520421 15 Protection Lamp but Above Normal Operational Range - Least Severe An abnormal acceleration is detected. order that the wheels can not spin any more. none
The controller detected an abnormal
decelleration, and will disable the
Exceed Abnormal Accelaration/Deceleration: Data Valid The driver should slow down, in order that the automatiic shifting for a certain time.
E4.11 520421 17 Protection Lamp but Below Normal Operational Range - Least Severe An abnormal decelleration is detected. wheels can not slip any more. none
The driver should take place in the operator seat
Operator is not seated with shiftlever not in and confirm his presence (cycle the shiftlever The controller detected that the operator is - Check operator seat switch
Exceed Operator seated conditions: Special Instruction neutral and/or the parking brake not through neutral and/or release the throttle not seated with the shiftlever not in neutral - Check parking brake
E6.0E 520422 14 Protection Lamp (consult documentation) activated. pedal) and/or the parking brake not activated. - Check shift lever
TCON detects that the turbine,
Exceed transmission speed limits: Data Valid but Above TCON will force engine idle to prevent Slow down the vehicle, in order that the speed intermediate or output speed is above its
E7.0F 520423 15 Protection Lamp Normal Operational Range - Least Severe damage. drops below the maximum speed limit. limit. none

Exceed Low High range conditions: Data Valid but Above Condition to change low high range selector Brake and stop the vehicle until this exceed code TCON detected that the vehicle is still
E8.0F 520424 15 Protection Lamp Normal Operational Range - Least Severe not furfilled. Vehicle has to stand still. is no longer present. moving. none
Condition to change from 4wd to 2wd or
Exceed 4WD/2WD drive conditions: Data Valid but Above visa versa not furfilled. Vehicle has to stand Brake and stop the vehicle until this exceed code TCON detected that the vehicle is still
E9.0F 520425 15 Protection Lamp Normal Operational Range - Least Severe still. is no longer present. moving. none
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

Depending on the clutch state, the


Exceed Cutch Energy: Data Valid but Above Normal TCON.H312 has closed or opened the clutch Clutch closing/slipping/inching took too
EA.0F 520426 15 Protection Lamp Operational Range - Least Severe without further modulation. No action needed long. none
Exceed code temperature not in operating range; Data
Valid but Below Normal Operational Range - Least Operating temperature not reached. Engine
EB.11 520427 17 Protection Lamp Severe throttle is limited. Heat up transmission. Operating temperature not reached none

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
- If the problem persists, Download an APT file
compatible with the active firmware into the
F0.00 520432 0 Turn power off and restart the vehicle. If the TCON.H.
- - - problem persists, contact maintenance for The controller encountered an unexpected - If the error code still persists, the data flash
F2.1F 520434 31 Stop Lamp Flashing Assert codes. TCON reverts to shutdown mode. troubleshooting. error. may be corrupt (contact Dana Belgium N.V.)
- If this occurs right after performing a firmware
update of the TCON.H, this should be solved by
Turn power off and restart the vehicle. If the The controller encountered an unexpected performing a normal power down of the
problem persists, contact maintenance for error. Most likely this is due to a bad ground TCON.H.
F0.12 520432 18 Stop Lamp Flashing Controller boots in restricted mode. TCON reverts to shutdown mode. troubleshooting. sense. - Check the Ground Sense line (pin 60)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 0 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.00 520435 0 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 0. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 1 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.01 520435 1 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 1. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 2 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.02 520435 2 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 2. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 3 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.03 520435 3 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 3. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 4 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.04 520435 4 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 4. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 5 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.05 520435 5 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 5. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 6 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.06 520435 6 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 6. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 7 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.07 520435 7 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 7. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 8 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.08 520435 8 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 8. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)

- If this occurs right after performing a firmware


update of the TCON, this should be solved by
performing a normal power down of the TCON.
During initialization the TCON detected that - If the problem persists, Download an APT file
flashgroup 9 is incomplete or partially compatible with the active firmware into the
Turn power off and restart the vehicle. If the corrupt. TCON.
problem persists, contact maintenance for TCON is stuck in shutdown mode until this is - If the error code still persists, the data flash
F3.09 520435 9 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 9. TCON reverts to shutdown mode. troubleshooting. solved. may be corrupt (contact Dana Belgium N.V.)
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

During initialization the TCON detected that - If this occurs right after performing a firmware
the logging part of the data flash is corrupt. update of the TCON, this should be solved by
Turn power off and restart the vehicle. If the All functional logging data (like travelled performing a normal power down of the TCON.
problem persists, contact maintenance for distance etc..) but also error logging data - if the problem persists, contact Dana Belgium
F3.0A 520435 10 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 10. TCON reverts to shutdown mode. troubleshooting. will be lost and reset to zero. N.V.

During initialization the TCON detected that - If this occurs right after performing a firmware
the logging part of the data flash is corrupt. update of the TCON, this should be solved by
Turn power off and restart the vehicle. If the All functional logging data (like travelled performing a normal power down of the TCON.
problem persists, contact maintenance for distance etc..) but also error logging data - if the problem persists, contact Dana Belgium
F3.0B 520435 11 Stop Lamp Flashing APC Data Flash partially corrupt: parameter group 11. TCON reverts to shutdown mode. troubleshooting. will be lost and reset to zero. N.V.

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 0 is - If the error code still persists, the data flash
F4.00 520436 0 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 0. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 1 is - If the error code still persists, the data flash
F4.01 520436 1 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 1. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 2 is - If the error code still persists, the data flash
F4.02 520436 2 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 2. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 3 is - If the error code still persists, the data flash
F4.03 520436 3 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 3. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 4 is - If the error code still persists, the data flash
F4.04 520436 4 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 4. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 5 is - If the error code still persists, the data flash
F4.05 520436 5 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 5. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 6 is - If the error code still persists, the data flash
F4.06 520436 6 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 6. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 7 is - If the error code still persists, the data flash
F4.07 520436 7 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 7. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 8 is - If the error code still persists, the data flash
F4.08 520436 8 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 8. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)

- Download an APT file compatible with the


During initialization the TCON detected that active firmware into the TCON.
a critical part of the data flash group 9 is - If the error code still persists, the data flash
F4.09 520436 9 Stop Lamp Flashing APC Data Flash permanently corrupt: parameter group 9. TCON reverts to shutdown mode. Contact maintenance for troubleshooting. corrupt. TCON is stuck in shutdown mode. may be corrupt (contact Dana Belgium N.V.)
This could mean that an invalid Check the activated configuration set for this
F5.00 520437 0 Stop Lamp Flashing Dana Configuration Error TCON reverts to shutdown mode. Contact maintenance for troubleshooting. configuration set is selected. vehicle.
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

- Check the voltage connections on the TCON.


Most likely pin 60 (ground) is not connected or
faulty.
This can be the result of a faulty wiring. The - If the error code still persists, the data flash
F5.12 520437 18 Stop Lamp Flashing ECU state unsafe TCON reverts to shutdown mode. Contact maintenance for troubleshooting. power supply for the ECU is not correct. may be corrupt (contact Dana Belgium N.V.)

F7.00 520439 0 Amber warning Flashing Severe engine limitation active due to low temperature. TCON limits the engine to the lowest limit. Heat up transmission.
F7.01 520439 1 Amber warning Flashing Engine limitation active due to low temperature. TCON limits the engine. Heat up transmission.

TCON prevents direction engagement until


the converter out and sump temperature is
F8.00 520440 0 Amber warning Flashing Direction selection not available due to low temperature. in the operating range. Heat up transmission.
Shut down the engine, heat up transmission by
F8.01 520440 1 Stop Lamp Flashing No transmission oil pressure. TCON engine shutdown request. heater. insufficient oil pressure was detected.

Action will depend on the type of Stop the vehicle, turn power off and restart the
(configuration) error, but in most cases vehicle. If the problem persists, contact An unexpected event occured that was Take note of the reported error code and
FX.XX 520432 - 520447 XX Stop Lamp Flashing Assert error: DANA reserved code TCON.L will revert to shutdown mode maintenance for troubleshooting detected by the TCON.L firmware. contact a DANA representative.

CALIBRATION
ERROR CODE EXPLANATION

x = 0 Pressure to current
Calibration.
Ex.06 [DEC] x = 1 Touch pressure Calibration During calibration the turbine speed signal does not At fill area calibration, timeout on full
Ex.06 [HEX] x = 2 Optimise fill time reach a minimum value. turbine pulldown.

x = 0 Pressure to current
Error detected, during P2mA, TchPrs or
Calibration.
fillArea.
Ex.10 [DEC] x = 1 Touch pressure Calibration
Ex.0A [HEX] x = 2 Optimise fill time Transmission failure during calibration.

x = 0 Pressure to current At fill area calibration, turbine speed


Calibration. doesn't decrease to start with turbine
Ex.14 [DEC] x = 1 Touch pressure Calibration During calibration the turbine speed signal does not pulldown detection.
Ex.0E [HEX] x = 2 Optimise fill time decrease.

x = 0 Pressure to current fill area calibration, at start of filling of


during calibration the turbine speed signal is too low to
Calibration. clutch, the turbine speed is below
start calibration.
Ex.16 [DEC] x = 1 Touch pressure Calibration parameter "Fill-TPD<SPD".
Ex.10 [HEX] x = 2 Optimise fill time

After filling phase and 2 seconds wait, the


measured torque is bigger than parameter
"DragTorqMax" or is bigger than parameter
E1.25 [DEC] "TouchTorq". (if TouchTorq is bigger than 0.
E1.19 [HEX] Touch pressure calibration. Early touch detection. Too much drag. This is set to zero for TE30)
timeout on detection of touch. ( measured
E1.26 [DEC] torque > (drag torque + parameter
E1.1A [HEX] Touch pressure calibration. No touch detection. TouchTorq))

E1.27 [DEC] Turbine speed does not reach value = 0 rpm at end of during touch pressure when at full pressure,
E1.1B [HEX] Touch pressure calibration. closing phase of the touch pressure calibration the turbine speed > 5 rpm.
E1.28 [DEC] turbine speed <= 5 rpm at end of touch
E1.1C [HEX] Release pressure calibration. Clutch does not close before release calibration runs. phase
TCON ERROR CODES & DESCRIPTIONS
Revision 2.54 - Firmware Version 2.04
Date: 3/3/2021

ERROR CODE
DANA [HEX] SAE J1939 DM 1 STATUS LAMP ERROR DESCRIPTION TCON ACTION DRIVER ACTION FAILURE CAUSE TROUBLESHOOTING
SPN FMI

E1.29 [DEC] Turbine speed signal does not reach a high enough value turbine speed <= 5 rpm at end of release
E1.1D [HEX] Touch pressure calibration. during release phase of the touch pressure calibration. phase
E0.27 [DEC]
E0.1B [HEX] Pressure to current Calibration. Measured pressure points do not allow interpolation.
E0.30 [DEC] maximum number of retries reached during P2mA for
E0.1E [HEX] Pressure to current Calibration. the peak to peak pressure.
E0.31 [DEC] During P2mA routine a pressure drop of more than 1 bar
E0.1F [HEX] Pressure to current Calibration. is detected.
E0.32 [DEC]
E0.20 [HEX] Pressure to current Calibration. At start of P2mA, the pressure signal is too high.