You are on page 1of 1

Domestic + CE Mark PRODUCT TESTING PLAN

QUALITY CONTROL & CONFORMANCE TESTING


CEG mass per unit area dimensions* rib tensile wide width tensile seams permeability AOS cbr drop cone abrasion Junction
Existing and DOMESTIC DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC
planned
product line GRI D5261 - D5199 - D6637 rib tensile D6637/4595 EN 10319 D4884 EN 10321 D4491 EN 11058 D4751 EN 12956 - EN 12236 - EN 918 D4886 EN 13427 GG2
Character. QC QC QC QC QC QC Conform. Correlate - Conform. - Conform. - Conform. - Conform. - Conform. - Conform. Conform.

Grid 1 yarn in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1


Grid 2 - in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1
Grid 3 - in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1
Grid 4 - in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1
Grid 5 - in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1
Grid 6 - in-house in-house in-house in-house in-house in-house 1 1 - - - - - - - 1 - 1 - 1 1

PRODUCT PERFORMANCE CHARACTERIZATION TESTING


Existing and MW install damage weathering-uv creep chemical resist biological resist hydrolysis protective eff direct shear pullout connection
planned
product line DOMESTIC DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK
GRI D5818/TRI EN 10722-1 D4355 EN 12224 D5262/GS10 EN 13431 - EN 12960 - EN12225 - EN 12447 - EN 1897 D5321 EN 12957-1 D6706 - D6638 - Status
Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character.

Grid 1 yarn 1 1 1 1 1 1 - 1 - 1 - 1 - - 3 1 3 - 2 - X,Y


Grid 2 - - 1 - - - - - - - - - - - - - - - - - -
Grid 3 - 1 1 - - 1 - - - - - - - - - 3 1 3 - 2 - X,Y
Grid 4 - - 1 - - - - - - - - - - - - - - - - - -
Grid 5 - - 1 - - - - - - - - - - - - - - - - - -
Grid 6 - 1 1 1 - 1 - - - - - - - - - 3 1 3 - 2 - X,Y
6 additional tests planned

Test ASTM EN Test ASTM EN QC - Quality control testing done routinely at the plant.
mass per unit area - - Installation Damage 3000 650
dimensions* - - weathering-uv 750 850 Conform. - Conformance testing done annually to document primary property
rib tensile - - creep 6500 250 R&H, 20%/min
wide width tensile 125 125 chemical resistance - 850 Character. - Charaterization testing done on a one-time basis, unless structure changed.
seams 100 185 biological resistance - 575
permeability 75 125 hydrolysis - 675
AOS 110 250 protective efficiency - 1300 Tests Complete
cbr - 175 direct shear 650 650
drop cone - 250 pullout 1350 - (1) = Block Type X * rib spacing, thickness, aperture size, open area, coating wt.
abrasion - 550 connection 900 - (2) = Block Type Y
junction strength 110 -
CEG 400 -
MW 300 -
Domestic + CE Mark PRODUCT TESTING COSTS - 2003
QUALITY CONTROL & CONFORMANCE TESTING
CEG mass per unit area dimensions* rib tensile wide width tensile seams permeability AOS cbr drop cone abrasion Junction
Existing and DOMESTIC DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC
planned
product line GRI D5261 - D5199 - D6637 rib tensile D6637/4595 EN 10319 D4884 EN 10321 D4491 EN 11058 D4751 EN 12956 - EN 12236 - EN 918 D4886 EN 13427 GG2
Character. QC QC QC QC QC QC Conform. Correlate - Conform. - Conform. - Conform. - Conform. - Conform. - Conform. Conform.

Grid 1 400 in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
Grid 2 - in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
Grid 3 - in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
Grid 4 - in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
Grid 5 - in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
Grid 6 - in-house in-house in-house in-house in-house in-house 125 125 - - - - - - - 175 - 250 - 550 110
400 0 0 0 0 0 0 750 750 0 0 0 0 0 0 0 1050 0 1500 0 3300 660
Subtotal 8410

PRODUCT PERFORMANCE CHARACTERIZATION TESTING


Existing and MW install damage weathering-uv creep chemical resist biological resist hydrolysis protective eff direct shear pullout connection
planned
product line DOMESTIC DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK DOMESTIC CE MARK
GRI D5818/TRI EN 10722-1 D4355 EN 12224 D5262/GS10 EN 13431 - EN 12960 - EN12225 - EN 12447 - EN 1897 D5321 EN 12957-1 D6706 - D6638 - Status
Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character. Character.

Grid 1 300 3000 650 750 850 6500 250 - 850 - 575 - 675 - - 1950 650 4050 - 1800 - X,Y
Grid 2 - - 650 - - - - - - - - - - - - - - - - - -
Grid 3 - 3000 650 - - 6500 - - - - - - - - - 1950 650 4050 - 1800 - X,Y
Grid 4 - - 650 - - - - - - - - - - - - - - - - - -
Grid 5 - - 650 - - - - - - - - - - - - - - - - - -
Grid 6 - 3000 650 750 - 6500 - - - - - - - - - 1950 650 4050 - 1800 - X,Y
300 9000 3900 1500 850 19500 250 0 850 0 575 0 675 0 0 5850 1950 12150 0 5400 additional tests planned
Subtotal 62750

Total 71160