You are on page 1of 213

MES SCHEDULE OF RATES-2021

REPRINTED IN July 2021


Prepared by: Sub Engr Muhammad Imtiaz & Wazir Khan

Description Unit Sl No Rate (Rs)

Buildings
Foundation, Trenches, Wells etc

Excavation as in Ordinary Soil upto 1.5 M depth, in Cum 1-1 221


foundation and pipe trenches upto 1.5 M wide, in shafts,
wells and independent holes upto 30 sqm each and throw
earth clear of edges of excavation within 10m. Timbering to
be paid extra (Foundation and Trench over 1.5 M widths will
be treated as Areas).
Same as item 1-1, but in Hard Soil. Cum 1-2 260

Same as item 1-1, but in Rock not requiring blasting. Cum 1-3 2053

Same as item 1-1, but in Rock requiring blasting. Cum 1-4 1718

Same as item 1-1, but in Rock requiring blasting but blasting Cum 1-5 3501
is prohibited.
Add to item 1-1 to 1-05 for each additional 1.5 M lift or part Cum 1-6 225
thereof
Excavation over areas as in Ordinary/Hard Soil upto 1.5 M Cum 1-7 207
depth, in foundation / excavations, throw earth clear of
edges of excavation within 50 M.
Same as item 1-7 but 1.5 M to 3 M depth. Cum 1-8 404
Same as item 1-7 but 3 M and upto 6 M depth. Cum 1-9 448
Same as item 1-7 but 6 M and upto 9 M depth. Cum 1-10 477
Same as item 1-7 but 9 M and upto 12 M depth. Cum 1-11 527
Excavation over areas as in Rock upto 1.5 M depth, in Cum 1-12 1454
foundation / to obtain earth for filling under floors / areas
etc., or for shafts, wells exceeding 30 sqm each, throw earth
clear of edges of excavation within 50 M.
Same as item 1-12, but in Rock through blasting. Cum 1- 13 710
Same as item 1-12, but in Rock requiring blasting but blasting Cum 1-14 2824
prohibited.

Add to item 1-7 to 1-14 for each additional 1.5 M lift or part Cum 1-15 150
thereof
Earth Filling

Earth filling as in Ordinary or hard soil, filling in foundation, Cum 1-16 240
pipe trenches, shafts, wells, independent holes, under floors
or around plinths etc., 1.5 M below or above Ground Level
(GL), with spoil obtained from excavation in trenches/over
areas within 50M including watering and compaction in 150
mm layer and dressing to required profile and shape.

Add to item 01-16, for each additional 1.5 M or part thereof, Cum 1- 17 48
above / below GL.
Lead

Load "materials" (like excavated soil / rock, demolished brick Cum 1-18 339
bats, bricks, sand and bitumen etc.), by any means (specified
in items 1-1 to 1-15) upto 1000 M, unload and stack or
spread.
Add for carrying soil / rock demolished brick bats, bricks, sand Cum 1- 19 78
and bitumen etc.), by any means, for each subsequent 1000
M or part thereof (specified in items 1-1 to 1-15), unload and
stack or spread.
Miscellaneous

Excavate hill side slips, or similar loose material of any Cum 1- 20 286
description and remove to a distance not exceeding 25M and
deposit where directed, (loose or packed measure to be
converted into solid measure).
Finish the surface of existing embankments in repair to a neat Sqm 1- 21 11
and finished profile including making up where necessary,
(earth utilized from borrow pits for making up be paid for
extra).
Compaction / Ramming Earth in 150mm layers except Cum 1- 22 36
watering.
Compaction / Ramming Earth in 150mm layers with Cum 1-23 43
Watering.
Brick bats or other approved filling in soakage pits etc. Cum 1-24 6128
Taking out brick bats, boulders, rubbish etc, from Soakage Cum 1- 25 678
pits and dispose off as ordered (supply and filling of brick-
bats or other approved filling not included).

Pumping out water from excavation etc, including all labour, Cum 1-26 271
use of pumps, plants etc (The net quantity raised to be paid
for). The lift not to exceeding 12 M. Conversion Factor 1000
lit = one Cum.
Roads and Runways etc
Clearing and Grubbing, all as specified. Sqm 1-27 17
Compaction of Natural Ground upto 95% Modified AASHTO Sqm 1-28 12
density all as specified.
Same as item 1-28 but 93% Modified AASHTO density. Sqm 1-29 12
Same as item 1-28 but 90% Modified AASHTO density. Sqm 1-30 10

Making Embankment, with the specified /approved soil Cum 1-31 445
obtained from borrow excavation including Loading within
Five KM, compaction in 150mm layers upto 95% Modified
AASHTO density, and dressing to required profile and shape
as specified.
Same as item 1-31 but upto 93% Modified AASHTO density. Cum 1-32 374

Same as item 1-31 but 90% Modified AASHTO density. Cum 1-33 347

Cutting of ordinary / hard soil of roadway / Runway / Hard Cum 1-34 221
standing stripping etc, and dispose off / collect spoil within 5
KM, complete, all as specified.
Cutting of Rock not requiring blasting of roadway etc. and Cum 1-35 3123
dispose off / collect spoil within Five (5) KM , complete, all as
specified.
Same as item 1-35 but as in Rock requiring blasting. Cum 1-36 1606

Same as item 1-35 but as in Rock requiring blasting, but Cum 1-37 6342
blasting prohibited.
Add for carrying material obtained as specified in items 1-35 Cum 1-38 230
to 1-37, for each sub sequent Five(5) KM or part thereof.

Description Unit SI No Rate (Rs)


Collection of Materials
Collection of sand, and crushed stones within a radius of 25 Cum 2-1 422
M and stacking to template (1/12th to be deducted from
measured quantum of stack).
Screening of crushed stones as directed and stacking to Cum 2-2 289
template (Measurement to be taken before screening) Using
one screen.
Cut or Fill
Cut or fill in Granular Soil not exceeding 150 mm, compact Sqm 2-3 12
formation surface by compacting equipment and roller upto
100% Modified AASHTO density, including filling in
depression with hard soil.
Same as item 02-03, but 95% Modified AASHTO density. Sqm 2-4 12
Same as item 02-03, but 90% Modified AASHTO density. Sqm 2-5 11

Cut or fill in soft or hard soil not exceeding 150 mm, dry roll Sqm 2-6 11
and compact formation surface by power roller including
filling in depression with hard soil.
Compaction
Roll and compact, Granular Soil formation surface / Cum 2-7 77
embankments upto 150 mm layers, by compaction
equipment and roller upto 100% Modified AASHTO density,
including filling in depression with hard soil.
Roll and compact, Cohesive Soil formation Cum 2-8 75
surfaces/embankments upto 150 mm layer, by compaction
equipment and roller upto 95% Modified AASHTO density,
including filling in depression with hard soil.

Same as item No. 02-8, but 90% Modified AASHTO density. Cum 2-9 71

Roll and compact, Formation Surface, embankment upto 150 Cum 2-10 71
mm layers, by roller, including filling in depression, with hard
soil.
Bottoming /Sub Base
Bottoming /sub base of any thickness as specified using Soil Cum 2-11 2551
Aggregates of CBR 30%, laid and compacted to 100%
Modified AASHTO density by appropriate compaction
equipment and roller.
Same as item 2-11 but with Granular Sub Base material, all as Cum 2-12 2714
specified.
Bottoming /sub base of any thickness as specified using Soil Cum 2-13 2399
Aggregates of CBR 30%, compacted, including rolling by
appropriate compaction equipment and roller and filling in
depression.
Base Course
Water Bound Macadam (WBM), Base Course of CBR 100%, Cum 2-14 3146
any thickness as specified, laid and compacted to 100%
Modified AASHTO density by appropriate compaction
equipment and roller.
Aggregate Base Course, of any thickness as specified, laid and Cum 2-15 2840
compacted to 100% Modified AASHTO density, by
appropriate compaction equipment and roller.

WBM, of any thickness as specified, including rolling, Cum 2-16 2374


compacting, filling in depression and watering during rolling.

Hot Surface Treatment


Hot Surface Dressing, Two Coat work, on WBM surface, not Sqm 2-17 572
previously treated with Hot Dressing, using Broken or
Crushed stone, all as specified.
Same as item 2-17 but , Three Coat work, all as specified. Sqm 2-18 702

Repairs
Scarifying WBM surface, by hand or by power, not exceeding Sqm 2-19 30
50 mm deep including removing not exceeding 50 M and
stacking for re-use.
Add to item 02-19, for every 25 mm or part thereof beyond Sqm 2-20 15
50 mm deep including removing not exceeding 50 M and
stacking for re-use.
Repair Pot-holes not exceeding one sqm each in surface of Sqm 2-21 724
roads by scarifying surfaces, cutting edges at least 25 mm
deep, sweeping free from dust and mud, coating surface with
Hot Dressing and filling with premix of crushed stones,
asphalt bitumen, and ramming it well.

Same as item 2-21 but by using with Asphalt cement, all as Sqm 2-22 741
specified.
Premix Carpet (Bit-Mac) On Asphaltic Surface
Providing and laying Premix Carpet of any thickness, Cum 2-23 21410
compacted on asphaltic surface, as specified, using asphalt
cement 60/70 or 80/100 and Broken / Crushed stone
including tack coat.
Premix Carpet (Bit-Mac) On WBM Surface
Providing and laying, Premix carpet of any thickness, Cum 2-24 22996
compacted on WBM surface, as specified, using asphalt
cement 60/70 or 80/100 and Broken or Crushed stone,
including prime coat.
Asphaltic Courses (Plant Mix)
Providing and laying, Asphaltic Base Course of any thickness, Ton 2-25 7485
as specified, with asphalt cement 60/70 or 80/100 using JMF
(except prime coat).
Providing and laying, Asphaltic Wearing Course of any Ton 2-26 8044
thickness, as specified, with asphalt cement 60/70 or 80/100,
using JMF (except tack coat).
Prime Coat / Tack Coat / Seal Coat
Prime Coat, on Base Course surface. Sqm 2-27 144
Tack Coat, on asphaltic surface. Sqm 2-28 77
Providing and laying Seal Coat using sand and asphalt Sqm 2-29 170
cement, all as specified.
Concrete – Roads, Hard Standings and Runways etc.

Providing and laying PCC with 4000 psi compressive Cum 2-30 13735
cylindrical strength all as specified in slabs for roads, hard
standings, etc., of any thickness, using Crushed stone,
including use and waste of form work (steel) and finishing
surface even and fair (not smooth).
Same as item 02-30, but PCC with 3000 psi compressive Cum 2-31 11845
cylindrical strength all as specified.
Providing Sand Cushion in layers as specified, under concrete Cum 2-32 1231
roads, hard standings and Runways etc.
Providing and Laying PQC Flexural Strength of 600 psi for Cum 2-33 17435
Runway, Taxiway Links, Lead-ins and Tarmac of any thickness
using Concrete Mix Design laid Manually all as specified.

Same as 2-33 but laid with fixed-form, mechanical paver, all Cum 2-34 22064
as Specified.
Same as 2-33 but laid with slip-form, mechanical paver, all as Cum 2-35 26661
Specified.
Wire Mattresses
Supply No 8 SWG, GI wire made up into mattress 100 x100 Sqm 2-36 979
mm mesh, fix and bind with 14 SWG wire (mattresses and
laps measured).
Same as item 02-36 but mattress 150 x 150 mm mesh. Sqm 2-37 799
Rapid Runway Repair
Lifting and placing of pre-cast RCC slabs, with a special lifting Sqm 2-38 772
beam including carriage as required, for Rapid Runway
Repairs.
Filling Sand between joints (3-6 mm thick) of pre-cast RCC Sqm 2-39 15
slabs for Rapid Runway Repairs and rolling with 6-8 ton roller
to make the surface perfectly level with adjacent surface.

Expansion Joints
Labour and necessary material for forming of Expansion joint Sqm 2-40 448
13 mm wide and leaving the joint clear for filling (length of
joint multiplied by thickness of joint). The filling of the joint
with requisite filler will be carried out by the specialists.

Providing and fixing, Expansion Cap 25 mm to 40 mm dia for Each 2-41 306
movement of dowels all as specified.
Speed Breakers / Studs
Providing and fixing Road speed Breaker with reflectorized Metre 2-42 10530
plastic, 350 mm wide and 50 mm high including end pieces
both sides complete with Bolts and plugs.

Same as 2-42 but with reflectorized EPM Rubber, all as Metre 2-43 8130
specified.
Same as 2-42 but with reflectorized Metal, all as specified. Metre 2-44 16530

Reflectorized Plastic Pavement Stud (10cm x 7.5 cm x 2 cm), Each 2-45 462
Raised type.
Same as 2-45 but having size (10 cm x 20 cm x 2 cm), Flush Each 2-46 726
type.
Same as 2-45 but Aluminum. Each 2-47 834
Jersey Barriers
Supply and Fix RCC pre-cast jersey barrier including lifting Metre 2-48 8793
and erection, all as specified.
Providing and laying new jersey barrier (PCC 4000 Psi), cast in Metre 2-49 4517
situ with slip form paver, all as specified.

Description Unit SI No Rate (Rs)


Plain Cement Concrete (PCC)
Providing and laying of lean concrete using crushed or Cum 3-1 6360
broken stone graded; 1:6:12, all as specified.
Same as 3-1 but PCC 1:4:8, all as specified. Cum 3-2 7075
Same as 3-1 but PCC 1:3:6, all as specified. Cum 3-3 7696
Providing and laying of PCC 1:3:6 all as specified in walls, Cum 3-4 9483
partitions, slabs, sills, copings, channels, steps, string courses,
corbels, pier caps, hinge stones, mantel pieces, louvers,
chimney tops etc., including setting, jointing and pointing.

Providing and laying of PCC with 3000 psi compressive Cum 3-5 8922
cylindrical strength in all non- structural elements except
formwork.
Same as item 3-5 including formwork and fair faces to Cum 3-6 10852
exposed surfaces.
Providing and laying of RCC with 3000 psi compressive Cum 3-7 10095
cylindrical strength in different structural elements
(foundation etc.) including form work all as specified.
Reinforcement measured and paid separately.

Same as item 3-7 except form work. Reinforcement Cum 3-8 8731
measured and paid separately.
Same as item 3-7 but in roof slabs, landings, walls, plinth Cum 3-9 13547
beams and bands etc. all as specified including form work
(reinforcement measured and paid separately).

Same as item 3-7 but columns, beams, stairs, posts, struts, Cum 3-10 13921
piers, lintels, and the like including form work, all as specified.
Reinforcement measured and paid separately.

Providing and laying of RCC with 3500 psi compressive Cum 3-11 15781
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.

Same as item 3-11 but in beams, columns, stairs, posts, Cum 3-12 16047
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-11 but in foundations, independent column Cum 3-13 12595
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.

Providing and laying of RCC with 4000 psi compressive Cum 3-14 16239
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.

Same as item 3-14 but in beams, columns, stairs, posts, Cum 3-15 16613
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-14 but in foundations, independent column Cum 3-16 13053
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.

Providing and laying of RCC with 5000 psi compressive Cum 3-17 16490
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.

Same as item 3-17 but in beams, columns, stairs, posts, Cum 3-18 16864
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-17 but in foundations, independent column Cum 3-19 13304
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.

Providing and laying of RCC with 6000 psi compressive Cum 3-20 17028
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.

Same as item 3-20 but in beams, columns, stairs, posts, Cum 3-21 17402
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-20 but in foundations, independent column Cum 3-22 13843
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.

Providing and fixing of PVC water stopper 250mm wide and Metre 3-23 2331
12 mm thick.
Same as 3-23 but 10 mm thick. Metre 3-24 2134
Same as 3-23 but 225 mm wide and 8 mm thick. Metre 3-25 1543
Same as 3-23 but 225 mm wide and 5 mm thick. Metre 3-26 952
Pre Cast Solid / Hollow Blocks
Providing and laying of PCC Solid Blocks for load bearing Cum 3-27 11188
walls as specified in building blocks walls including setting
and jointing in CM 1:6 upto Basement / GF roof level.

Same as item 3-27, but upto 1st floor roof level / Basement. Cum 3-28 11325
(1st lower ground level)
Same as item 3-27, but upto 2nd floor roof level / Basement. Cum 3-29 11462
(2nd lower ground level)
Providing and laying of PCC Solid Blocks for non - load Cum 3-30 10437
bearing walls as specified in building blocks walls including
setting and jointing in CM 1:6 upto GF roof level.

Same as item 3-30, but upto 1st floor roof level / Basement Cum 3-31 10725
(1st Lower Ground level).
Same as item 3-30, but upto 2nd floor roof level / Basement Cum 3-32 10711
(2nd Lower Ground level).
Providing and laying of PCC Hollow Blocks, for load bearing Cum 3-33 10868
walls, as specified in building blocks walls, including setting
and jointing in CM 1:6 upto Basement.
(1st Lower Ground) / GF roof level.

Same as item 03-33, but upto 1st floor roof level / Basement Cum 3-34 11005
st
(1 Lower Ground level).
Same as item 03-33, but upto 2nd floor roof level/ Basement Cum 3-35 11142
(2nd Lower Ground level).
Providing and laying of PCC Hollow Blocks, for non-load Cum 3-36 10112
bearing walls, as specified in building blocks walls, including
setting and jointing in CM 1:6 upto Basement / GF roof level

Same as item 03-36, but upto 1st floor roof level / Basement. Cum 3-37 10306
st
(1 lower ground level)
Same as item 03-36, but upto 2nd floor roof level / Cum 3-38 10386
Basement. (2nd lower ground level)
Pointing to PCC Solid / Hollow Blocks in CM (1:4). Sqm 3-39 171
Additional Labour Cost
Add labour cost for hoisting / lowering of concrete (Cast in Cum 3-40 118
situ) for each storey beyond 12 M above or below GL.

Same as item 03-40, but Pre-cast PCC Solid / Hollow blocks. Cum 3-41 186

RCC Jali
Supply and fix, 38mm thick Precast RCC jali, including setting Sqm 3-42 888
and jointing in CM 1:1, all as specified.
Same as item 03-42, but 50 mm thick. Sqm 3-43 1082
Same as item 03-42, but 75 mm thick. Sqm 3-44 1293
Fixing only of item 03- 42 to 03-44. Sqm 3-45 406
Add to item 03-42 to 03-45, if fixed in repair. Sqm 3-46 107
Kerb Stone
Providing and laying Precast PCC Kerb-stone, size 300 x 300 x Metre 3-47 473
150 mm including setting, jointing and pointing in CM 1:4 all
as specified.
Same as item 03-47, but size 350 × 300 × 150 mm. Metre 3-48 550
Same as item 03-47, but size 450 × 300 × 150 mm. Metre 3-49 574
Expansion Joints
Form expansion joint 13mm thick in RCC roof or floor slabs Sqm 3-50 2647
etc., and fill in with bitumen grade 10-20.
Supply and fix, Copper sheet 24 gauge in expansion joint Sqm 3-51 7116
(girth measurement).
Same as item 03-51, but using 26 gauge. Sqm 3-52 5825
Supply and fix, GI sheet 24 gauge in expansion joints (girth Sqm 3-53 5569
measurement).
Supply and fix Aluminium cover strip 60mm wide and 2mm Metre 3-54 342
thick with all fittings complete for all joints.
Same as above 3-54 but 100 mm wide. Metre 3-55 338
Same as item 03-54, but fixed in sections. Metre 3-56 617
Extra for lead beyond 10 Km to 15 Km or part thereof for Cum 3-57 260
weigh batch concrete.
Add to item 3-7 to 3-10, if crystalline water proofing chemical Cum 3-58 6336
material is added to cement at the rate of 2% by weight.

Add to item 3-11 to 3-13, if crystalline water proofing Cum 3-59 8064
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-14 to 3-16, if crystalline water proofing Cum 3-60 8218
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-17 to 3-19, if crystalline water proofing Cum 3-61 9120
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-20 to 3-22, if crystalline water proofing Cum 3-62 9216
chemical material is added to cement at the rate of 2% by
weight.

Description Unit SI No. Rate (Rs)


Brickwork (Ground Floor)
Burnt brick work, in walls 115 mm thick, laid and jointed in Cum 4-1 13523
CM 1:3, straight or to curve with inner radius of 6m and over,
upto G.F roof level.
Same as item 04-1, but CM 1:4. Cum 4-2 13236
Same as item 04-1, but CM 1:6. Cum 4-3 12905
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-4 12315
in CM 1:3, straight or to curve with inner radius of 6m and
over, upto G.F roof level.
Same as item 04-4, but CM 1:4. Cum 4-5 12027
Same as item 04-4, but CM 1:6. Cum 4-6 11699
Brickwork (First Floor)
Burnt brick work, in wall 115 mm thick, laid and jointed in CM Cum 4-7 13720
1:3, straight or to curve with inner radius of 6m and over,
upto Ist floor roof level.
Same as item 04-7, but CM 1:4. Cum 4-8 13429
Same as item 04-7, but CM 1:6. Cum 4-9 13106
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-10 12467
in CM 1:3, straight or to curve with inner radius of 6m and
st
over, upto 1 floor roof level.
Same as item 04-10, but CM 1:4. Cum 4-11 12179
Same as item 04-10, but CM 1:6. Cum 4-12 11855
Brickwork (Second Floor)
Burnt brick work, in walls 115 mm thick, laid and jointed in Cum 4-13 13916
CM 1:3, straight or to curve with inner radius of 6m and over,
upto 2nd floor roof level.
Same as item 04-13, but CM 1:4. Cum 4-14 13627
Same as item 04-13, but CM 1:6. Cum 4-15 13302
Burnt brick work, in walls over 115 mm thick, laid and jointed Cum 4-16 12621
in CM 1:3, straight or to curve with inner radius of 6m and
over, upto 2nd floor roof level.
Same as item 04-16, but CM 1:4. Cum 4-17 12332
Same as item 04-16, but CM 1:6. Cum 4-18 12006
Brickwork (Below Ground)
Burnt brick work, in wall 115 mm thick, laid and jointed in CM Cum 4-19 14308
1:3, straight or to curve with inner radius of 6m and over,
upto 4.25 m depth.
Same as item 04-19, but CM 1:4. Cum 4-20 14019
Same as item 04-19, but CM 1:6. Cum 4-21 13694
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-22 13214
in CM 1:3, straight or to curve with inner radius of 6m and
over, upto 4.25 m depth.
Same as item 04-22, but CM 1:4. Cum 4-23 12925
Same as item 04-22, but CM 1:6. Cum 4-24 12600
Burnt brickwork, in wall 115 mm thick, laid and jointed in CM Cum 4-25 14544
1:3, straight or to curve with inner radius of 6m and over,
from 4.25m to 8.25 m depth.
Same as item 04-25, but CM 1:4. Cum 4-26 14277
Same as item 04-25, but CM 1:6. Cum 4-27 13929
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-28 13182
in CM 1:3 straight or to curve with inner radius of 6m and
over, from 4.25 m to 8.25 m depth.
Same as item 04-28, but CM 1:4. Cum 4-29 12893
Same as item 04-28, but CM 1:6. Cum 4-30 12567
Burnt brick work, in wall 115 mm thick, laid and jointed in CM Cum 4-31 14792
1:3, straight or to curve with inner radius of 6m and over,
from 8.25 m to 12 m depth.
Same as item 04-31, but CM 1:4. Cum 4-32 14503
Same as item 04-31, but CM 1:6. Cum 4-33 14177
Burnt brick work, in walls over 115 mm thick, laid and jointed Cum 4-34 13397
in CM 1:3 straight or to curve with inner radius of 6m and
over, from 8.25 m to 12 m depth.
Same as item 04-34, but CM 1:4. Cum 4-35 13092
Same as item 04-34, but CM 1:6. Cum 4-36 12767
Additional Labour Cost
Additional labour cost, for each story of building above 2nd Cum 4-37 379
floor roof level, for burnt brick work, straight or curve with
inner radius 6m and over, in any mortar.
Brickwork (Well etc.)
Burnt brick work, in wall 115 mm thick, laid and jointed in CM Cum 4-38 16352
1:3, straight or to curve with inner radius of less than 6m and
upto 4.25 m depth.
Same as item 04-38, but CM 1:4. Cum 4-39 16063
Same as item 04-38, but CM 1:6. Cum 4-40 15737
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-41 14580
in CM 1:3 straight or to curve with inner radius less than 6m,
upto 4.25 m depth.
Same as item 04-41, but CM 1:4. Cum 4-42 14291
Same as item 04-41, but CM 1:6. Cum 4-43 13965
Burnt brick work, in wall 115 mm thick laid and jointed in CM Cum 4-44 16800
1:3, straight or to curve with inner radius less than 6m, above
4.25m to 8.25 m depth.
Same as item 04-44, but CM 1:4. Cum 4-45 16512
Same as item 04-44, but CM 1:6. Cum 4-46 16186
Burnt brick work in wall over 115 mm thick laid and jointed in Cum 4-47 14853
CM 1:3 straight or curve with inner radius less than 6m,
above 4.25 m to 8.25 m depth.
Same as item 04-47, but CM 1:4. Cum 4-48 14566
Same as item 04-47, but CM 1:6. Cum 4-49 14239
Burnt brick work in wall 115 mm thick laid and jointed in CM Cum 4-50 17243
1:3 straight or to curve with inner radius of less than 6m,
above 8.25 m to 12 m depth.
Same as item 04-50, but CM 1:4. Cum 4-51 16955
Same as item 04-50, but CM 1:6. Cum 4-52 16629
Burnt brick work, in wall over 115 mm thick, laid and jointed Cum 4-53 15127
in CM 1:3, straight or to curve with inner radius of less than
6m, above 8.25 m to 12 m depth.
Same as item 04-53, but CM 1:4. Cum 4-54 14838
Same as item 04-53, but CM 1:6. Cum 4-55 14512
Arches
Cut or rubbed brick work, in arches and vaults etc., laid and Cum 4-56 30766
jointed in CM 1:3.
Same as item 04-56, but CM 1:4. Cum 4-57 30478
Cavity Walls
Extra to brick for forming cavity, 57 mm wide, laid and jointed Sqm 4-58 663
in CM 1:3, as specified, one face of the wall to be measured.

Facing with machine tiles built in CM(1:3) (228 x 114 x 43mm Sqm 4-59 3306
to 47mm thick)
Pointing to Brickwork
Pointing, flush or recessed in CM 1:3, to old or new brick Sqm 4-60 383
work, built in any mortar.
Same as item 04-60, but in CM 1:4. Sqm 4-61 377
Same as item 04-60, but in CM 1:6. Sqm 4-62 371
Tuck pointing, in CM 1:3, to old or new brick work, built in Sqm 4-63 436
any mortar.
Same as item 04-63, but in CM 1:4. Sqm 4-64 431
Same as item 04-63, but in CM 1:6. Sqm 4-65 425
Struck pointing, in CM 1:1, to old or new brick work, built in Sqm 4-66 479
any mortar.
Same as item 04-66, but in CM 1:2. Sqm 4-67 455
Racking out joints of old walls, built in any mortar, including Sqm 4-68 200
preparing surface for re-pointing.
Damp Proof Course (DPC)
13mm thick DPC of CM 1:3 mixed with approved water Sqm 4-69 449
resistant material 3% by weight.
Same as item 04-69, but 20 mm thick. Sqm 4-70 624
50mm thick P.C.C 1:2:4, using 3mm aggregate and finished Sqm 4-71 872
smooth with steel float, covered with two coats, each of hot
bitumen @ 0.75 kg per Sqm and blinded with 0.012 cum of
sand per Sqm.
Miscellaneous
Cutting out, in any mortar, and facing up with brick work in Sqm 4-72 1518
CM 1:3, where old walls had been binded in and removed.

Cutting out, Decayed brick work in any mortar, and re-facing Sqm 4-73 1745
with new bricks (any bond) in CM 1:3 and pointing/ striking in
same mortar 115 mm thick.
Brick Shuttering
Shuttering for slabs, landing, lintels, beams, columns and the Sqm 4-74 672
like etc.

Description Unit SI No. Rate (Rs)


Stone Walling
Random Rubble - Stone Masonry Brought Upto Course

Random Rubble stone masonry brought upto Courses, every Cum 5-1 3874
45 cm to 105 cm and 110 cm, roughly hammer dressed
stone, well bonded, faced with hammer dressed selected
stone, with square quoins and jambs, any thickness in
building work and laid dry.
Same as item 05-1, but laid and jointed in CM 1:4. Cum 5-2 6222
Same as item 05-1, but laid and jointed in CM 1:6. Cum 5-3 5880
Same as item 05-1, but in retaining wall. Cum 5-4 4311
Same as item 05-4, but laid and jointed in CM 1:4. Cum 5-5 6813
Same as item 05-4, but laid and jointed in CM 1:6. Cum 5-6 6471
Pointing
Pointing struck, flush or recessed to old or new stone Sqm 5-7 575
masonry, any type, in CM 1:3.
Same as item 05-7, but Coloured, CM 1:3. Sqm 5-8 618
Same as item 05-7, but in CM 1:4. Sqm 5-9 570
Same as item 05-9, but Coloured, CM 1:4. Sqm 5-10 606
Tuck pointing to old or new stone masonry, any type, in CM Sqm 5-11 581
1:3.
Same as item 05-11, but Coloured, CM 1:3. Sqm 5-12 620
Same as item 05-11, but in CM 1:4. Sqm 5-13 572
Same as item 05-13, but Coloured, CM 1:4. Sqm 5-14 608
Struck pointing to old or new stone masonry, any type, in CM Sqm 5-15 617
1:1.
Same as item 05-15, but Coloured, CM 1:1. Sqm 5-16 653
Dressed Stonework
Stone in blocks, with faces, beds and joints on One-Line Cum 5-17 9950
Dressed as in bands, string and plinth courses, blocking
courses pilaster, cornice, columns, caps, bases, copings,
kneelers, lintels etc., (measured net), built in CM 1:4.

Same as per item 05-17, but built in CM 1:6. Cum 5-18 9608
Boulders in Crates, Pitching, etc.
Boulder filling dry hand packed as filling behind retaining Cum 5-19 1734
walls in pitching and bunds.
Boulder filling in crates including laying readymade wire Cum 5-20 1914
mattress in position hand packing boulders folding wire
mattress and lying its edges so as to form crates of the
required shape and size etc. but excluding wire mattress and
anchorage of crates, which are to be paid separately.

Miscellaneous Repairs
Racking out Only, joints of stone masonry, in any mortar, Sqm 5-21 42
including preparation of surface for re-pointing, in any
mortar.
Refastening or re-securing, ends of balusters, newels, rag Each 5-22 100
bolts let into stone, re-cutting of mortices and re-running
with cement.
Boulders laid, jointed and pointed in CM 1:4 in pitching. Cum 5-23 6262

Description Unit SI No. Rate (Rs)


Wood Work
Supply and fix timber in scantling, 1st Class softwood Cum 6-1 192665
(Deodar), complete.
Same as item 06-1, but 1st Class hardwood (Sheesham). Cum 6-2 134018

Supply and fix timber in scantling framed, 1st Class softwood Cum 6-3 203290
(Deodar), complete, all as specified.
Same as item 06-3, but 1st Class hardwood (Sheesham). Cum 6-4 144287

Supply and fix, timber in scantling wrought and framed, 1st Cum 6-5 203385
Class softwood (Deodar), complete.
Same as item 06-5, but 1st Class hardwood (Sheesham). Cum 6-6 146838

Fillets
Supply and fix, fillets not exceeding 12.90sqcm sectional area Metre 6-7 210
of 1st Class softwood (Deodar) wrought and fixed with
screws.
Same as item 06-7, but 1st Class hardwood (Sheesham). Metre 6-8 164

Supply and fix fillets exceeding 12.90 sqcm but not exceeding Metre 6-9 346
25.80 sqcm sectional area of 1st Class softwood (Deodar),
wrought and fixed with screws.
Same as item 06-9, but 1st Class hardwood (Sheesham). Metre 6-10 265

Supply and fix fillets exceeding 25.80 sqcm but not exceeding Metre 6-11 539
38.70 sqcm in sectional area of 1st Class softwood (Deodar),
wrought and fixed with screws.
Same as item 06-11, but 1st Class hardwood (Sheesham). Metre 6-12 396

Boarding
Supply and fix, chipboard (600 density), 13 mm thick. Sqm 6-13 700
Same as item 06-13, but 19 mm thick. Sqm 6-14 840
Same as item 06-13, but 25 mm thick. Sqm 6-15 1051
Supply and fix, ply wood 3 mm thick commercial ply in any Sqm 6-16 587
position.
Same as item 06-16, but Sheesham ply. Sqm 6-17 604
Same as item 06-16, but Teak ply. Sqm 6-18 643
Add to item 06-16, 06-17, and 06-18, if fixed in repairs. Sqm 6-19 66
Supply and fix 19 mm thick Chip board veneered both sides Sqm 6-20 1228
of specified pattern in any position Commercial.
Same as item 06-20, but Sheesham veneered. Sqm 6-21 1228
Same as item 06-20, but Teak veneered. Sqm 6-22 1291
Supply and fix 10 mm thick MDF laminated sheet of specified Sqm 6-23 923
pattern in any position.
Same as item 6-23 but 16 mm thick all as specified. Sqm 6-24 1367
Same as item 6-23 but 24 mm thick all as specified. Sqm 6-25 2158
Old Roof Trusses
Taking down, old timber trusses upto 8 M span. Each 6-26 1440
Same as item 06-26, but exceeding 8M, not exceeding 11 M Each 6-27 2100
span.
Hoisting and fixing old timber trusses upto 8 M span. Each 6-28 2820
Same as item 06-28, but exceeding 8M and not exceeding 11 Each 6-29 3480
M span.
Trellis Work
Supply and fix 40 mm x 10 mm first class soft wood (Deodar), Sqm 6-30 4558
wrought trellis work two way, square or diagonal at 50 mm
space and 75 mm x 25 mm fillet framing all around fixed,
complete.
Moulding and Turned work
Supply and fix 1st Class softwood (Deodar), moulding and Metre 6-31 600
turned work exceeding 75 mm but not exceeding 150 mm, 25
mm thick.
Same as item 06-31, but 40 mm thick. Metre 6-32 1060
Same as item 06-31, but 50 mm thick. Metre 6-33 1330
Workmanship, Plugging etc.
Labour only beads, chamfers, splay, rebate, rounded angles, Metre 6-34 198
tongues, grooves, rounded nosings, staff beads, flutes, each
exc. 6mm and not exceeding 75 mm width or girth,
mouldings and turned work not exceeding 75mm girth,
where not otherwise provided. Rate per 25 mm turned girth
or part thereof, 1st Class softwood (Deodar).

Same as item 06-34, but 1st Class hardwood (Sheesham). Metre 6-35 231

Supply and fix Rawal plug 25 mm long for boards etc. not Metre 6-36 85
exceeding 200 mm c/c (in any wall, in any mortar or
concrete)
Same as item 06-36, but 50mm long. Metre 6-37 86
Jobbing Work for all items in 1st Class soft wood (Deodar)/
hard wood (Sheesham)
Resecuring of wire gauze (fly and mosquito netting with fillet Sqm 6-38 114
and or framing), hard / soft wood.
Taking up or down and refixing of wire gauze (fly and Sqm 6-39 180
mosquito netting with fillet and / or framing), hard / soft
wood.
Taking up or down wire gauze (fly and mosquito netting with Sqm 6-40 66
fillets and / or framing) and removing to store, (hard / soft
wood).
Taking up or down and refixing of shelves including brackets, Sqm 6-41 213
fillets and window board with beads etc., (hard / soft wood).

Taking up or down shelves including brackets, fillets and Sqm 6-42 99


window boards with beads etc., and removing to store (hard
/ soft wood).
Taking up or down and refixing of skirting wood, any width Sqm 6-43 213
including grounds if required, (hard / soft wood).
Taking up or down skirting wood, any width including Sqm 6-44 66
grounds and removing to store, (hard / soft wood).
Taking up or down and refixing boarding flooring in area not Sqm 6-45 278
exceeding 4.65 sqm super, (hard / soft wood).
Same as item 06-45 but in patches, in repairs to existing Sqm 6-46 327
floors, including cutting to joints etc., (hard / soft wood).

Re-securing of casings (box) to pipes, any girth, (hard / soft Sqm 6-47 66
wood).
Taking up or down and refixing of casing (box) to pipes any Metre 6-48 132
girth, (hard / soft wood).
Taking up or down and removing to store of casing (box) to Metre 6-49 33
pipes any girth, (hard / soft wood).
Re-securing of fillets, mouldings, quadrant skirting, hand rails, Metre 6-50 72
peg rails, etc, (hard / soft wood).
Taking up and down and refixing of fillets, mouldings, Metre 6-51 105
quadrant skirting, hand rails, peg rails, etc., (hard / soft
wood).
Taking up or down fillets, moldings, quadrant skirting, hand Metre 6-52 33
rails, peg rails etc., and removing to store, (hard / soft wood).

Taking up or down and refixing of scantling in any position, Cum 6-53 9000
(hard / soft wood).

Description Unit SI No. Rate (Rs)


Solid Wooden Doors
Supply and fix, 1st Class Soft Wood (Deodar) Framed and Sqm 7-1 13763
Panelled Doors, gates etc., including chowkats, hold fasts,
and mongery, all as specified, 32 mm thick.
Same as item 7-1, but 38 mm thick. Sqm 7-2 14808
Supply and fix, 1st Class Hard Wood (Ash wood) Framed and Sqm 7-3 19826
Panelled Doors, gates including chowkats, hold fasts and
mongery, all as specified, 32 mm thick.
Same as item 7-3, but 38 mm thick. Sqm 7-4 20514
Supply and fix, 1st Class Hard Wood (Mahogany) Framed and Sqm 7-5 19562
Panelled Doors, gates etc., including chowkats, hold fasts and
monger, all as specified, 32 mm thick.

Same as item 7-5, but 38 mm thick. Sqm 7-6 20239


Supply and fix, 1st Class Hard Wood (Sheesham) Framed and Sqm 7-7 12771
Panelled Doors, gates etc. including chowkats, hold fasts and
mongery, all as specified , 32 mm thick.

Same as item 7-7, but 38 mm thick. Sqm 7-8 13724


Deduct from item 7-1 and 7-2, if chowkat 1st Class Soft wood Sqm 7-9 4675
(Deodar) not supplied and fixed.
Deduct from item 7-3, 7-4, 7-5, and 7-6 if chowkat 1st Class Sqm 7-10 7099
Hardwood (Ashwood / Mahogany) not supplied and fixed.

Deduct from item 7-7 and 7-8, if chowkat 1st Class Hardwood Sqm 7-11 4100
(Sheesham) not supplied and fixed.
Glazed / Gauzed Doors
Supply and fix, 1st Class Soft Wood (Deodar), Glazed doors, Sqm 7-12 12927
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with hinges or pivots
and mongery all as specified, 32 mm thick.

Same as item 7- 12, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-13 13211
Same as item 7-12, but 38 mm thick. Sqm 7-14 13280
Same as item 7-14, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-15 13224
Deduct from item 7-12 to 7-15, if chowkats not supplied and Sqm 7-16 7264
fixed.
Supply and fix, 1st Class Hard Wood (Ash wood), Glazed Sqm 7-17 18630
doors with moulded or chamfered bars, panels filled in with
glass including chowkats, holdfasts and hung with hinges or
pivots and mongery all as specified, 32 mm thick.

Same as item 7-17, but gauzed, 9x9 mesh, 24 BG. Sqm 7-18 18507
Same as item 7-17, but 38 mm thick. Sqm 7-19 19186
Same as item 7-19, but gauzed, 9x9 mesh 24 BG. Sqm 7-20 19156
Deduct from item 7-17 to 7-20, if chowkats not supplied and 7-21 10023
fixed.
Supply and fix, 1st Class Hard Wood (Mahogany), Glazed Sqm 7-22 17381
doors with moulded or chamfered bars, panels filled in with
glass including chowkats, holdfasts and hung with hinges or
pivots and mongery all as specified, 32 mm thick.

Same as item 7-22, but gauzed 9x9 mesh 24 gauge. Sqm 7-23 17339
Same as item 7- 22, but 38 mm thick. Sqm 7-24 18066
Same as item 7-24, but gauzed 9x9 mesh 24 BG. Sqm 7-25 18527
Deduct from item 7-22 to 7-25, if chowkats not supplied and Sqm 7-26 9854
fixed.
Supply and fix 1st class Hard Wood (Sheesham), Glazed doors Sqm 7-27 11855
with moulded or chamfered bars, angels filled in with glass
including chowkats, holdfasts hung with hinges or pivots and
mongery all as specified, 32 mm thick.

Same as item 7-27, but gauzed, 9X9 mesh, 24 BG. Sqm 7-28 11832
Same as item No 7-27, but 38 mm thick. Sqm 7-29 12532
Same as item 7-29, but gauzed, 9x9 mesh, 24 BG. Sqm 7-30 12511
Deduct from item 7-27 to 7- 30, if chowkats not supplied and Sqm 7-31 5410
fixed.
Deduct from item 7-13, 7-15, 7-18, 7-20, 7-23, 7-25, 7-28, Sqm 7-32 561
and 7-30, if mosquito proof gauze, 16 x 16 mesh, 26 gauge is
used.
Supply and fix, 1st Class Soft Wood (Deodar) Framed and Sqm 7-33 14086
Panelled doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fast and mongery, all as
specified, 32 mm thick.
Same as item 7-33, but 38 mm thick. Sqm 7-34 14161
Supply and fix, 1st Class Hard Wood (Ash wood), Framed and Sqm 7-35 18895
Panelled doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fasts, and monger, all as
specified, 32 mm thick.
Same as item 7-35, but 38 mm thick. Sqm 7-36 19483
Supply and fix, 1st Class Hard Wood (Mahogany) Framed and Sqm 7-37 18658
Panelled Doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fasts and mongery, all as
specified , 32 mm thick.
Same as item 7-37, but 38 mm thick. Sqm 7-38 19233
Deduct from item 7-33 and 7-34, if chowkat 1st Class Soft Sqm 7-39 4675
wood (Deodar) not supplied and fixed.
Deduct from item 7-35, 7-36, 7-37 and 7-38 if chowkat 1st Sqm 7-40 7099
Class Hardwood (Ashwood / Mahogany ) not supplied and
fixed.
Supply and fix, Solid Flush door, Teak veneered, 38 mm thick Sqm 7-41 13183
including mongery, without chowkats.
Same as item 7-41, but Sheesham veneered. Sqm 7-42 13104
Same as item 7-41, but Commercial veneered. Sqm 7-43 13072
Supply and fix, Solid Flush door, Teak veneered, 32 mm thick Sqm 7-44 11798
including mongery, without chowkats.
Same as item 7-44, but Sheesham veneered. Sqm 7-45 11720
Same as item 7-44, but Commercial veneered. Sqm 7-46 11687
Supply and fix, Solid Flush door, Teak veneered, 25 mm thick Sqm 7-47 10399
including mongery, without chowkats.
Same as item 7-47, but Sheesham veneered. Sqm 7-48 10321
Same as item 7-47, but Commercial veneered. Sqm 7-49 10288
Same as item 7-47 to 7-49 but Fixing only. Sqm 7-50 492
Add to item 7-47 to 7-50, if fixed in Repairs. Sqm 7-51 33
Supply and fix, Hollow Flush Door, Teak Veneered, 38 mm Sqm 7-52 9380
thick including mongery, all as specified, without chowkats.

Same as item 7-52, but Sheesham veneered. Sqm 7-53 9329


Same as item 7-52, but Commercial veneered. Sqm 7-54 9238
Supply and fix, Hollow Flush Door, Teak Veneered, 32 mm Sqm 7-55 7863
thick including mongery, all as specified, without chowkats.

Same as item 7-55, but Sheesham veneered. Sqm 7-56 7785


Same as item 7-55, but Commercial veneered. Sqm 7-57 7719
Supply and fix, Hollow Flush door, MDF (Medium Density Sqm 7-58 5392
Fibre board), 38 mm thick with Malaysian ply 3mm thick with
panels on both sides including internal, 1st Class Soft Wood
(Deodar) frame, 75mm x 32 mm, hydraulically hot pressed
with glue, in any design, shape and pattern, complete,
including iron mongery, except chowkat.

Supply and fix Tubular Particle Board Engineered door, 38 Sqm 7-59 9324
mm thick including mongery, all as specified, without
chowkats.
Add to 7-41 to 7-49 and 7-52 to 7-59, if chowkat 1st Class Sqm 7-60 4675
Soft Wood (Deodar) supplied and fixed.
Aluminium Doors
Supply Aluminium Sliding Door, Deluxe Quality, of Anodized Sqm 7-61 8768
Aluminium extruded section in any size, colour and texture,
including fixing on concrete, wood or steel frames, complete
except glass, lock and handle.

Same as item 7-61 but Premium Quality, all as specified. Sqm 7-62 9368

Supply Aluminium Swing door, Single shutter, Deluxe Quality Sqm 7-63 8960
of Anodized Aluminium extruded section in any size, colour
and texture as specified including fixing on concrete, wooden
or steel frames, complete except glass, lock and handle.

Same as item 7-63 but Premium Quality, all as specified. Sqm 7-64 10112

Supply Aluminium Swing door, Double shutter, Deluxe Quality Sqm 7-65 9428
of Anodized Aluminium extruded section in any size, colour
and texture as specified including fixing on concrete, wooden
or steel frames, complete except glass, lock and handle.

Same as item 7-65 but Premium Quality, all as specified. Sqm 7-66 10328
Fixing only, Aluminium door any type on concrete, wooden or Sqm 7-67 495
steel frames, complete, except glass, lock and handle.

uPVC Doors
Supply and fix, uPVC Sliding Door, 37 mm thick shutter with Sqm 7-68 10372
frame 80mm x 50mm exceeding 3.5 sqm each in white colour
including all necessary fittings, mongery, fly proof netting
except glass, complete all as specified.
Same as item 7-68, but coloured. Sqm 7-69 18377
Supply and fix, uPVC Door, 60 mm thick shutter for full glass Sqm 7-70 15286
with frame complete exceeding 1.9 sqm each, in white colour
including necessary fittings, mongery except glass, complete
all as specified.
Same as item 7-70, but coloured. Sqm 7-71 16935
Same as item 7-70, but with groove panel 20 mm thick, filled Sqm 7-72 21164
instead of glass, as specified complete in white colour.

Same as item 7-72, but coloured. Sqm 7-73 23760


Chowkats
Supply and fix 1st class soft wood (Deodar) Dolly frame Sqm 7-74 6549
chowkat using 57 mm x 57 mm fillets on edge sides of wall
and @ 381 mm c/c cross fillets, covered with 3mm
commercial ply, including architrave on both sides (inside/
outside), not exceeding 12.90 sqcm in any design/shape, hold
fasts, bitumen coating on wall side of frame and wood
preservative on remaining sides of frame, gaps filled with PCC
1:2:4 for 230mm wall, complete, all as specified.
(Single/Double rebate).
Same as item 7-74 but sheesham ply. Sqm 7-75 6563
Same as item 7-74 but teak ply. Sqm 7-76 6581
Same as item 7-74 but for 345 mm wall, complete, all as Sqm 7-77 7277
specified.
Same as item 7-77 but sheesham ply. Sqm 7-78 7294
Same as item 7-77 but teak ply. Sqm 7-79 7333
Supply and fix, Steel Chowkat press-moulded 16 SWG, for Metre 7-80 949
115 mm walls, single leaf, complete, including hold fast, ties
for lateral movement, PCC 1:2:4 cavity filling etc, including
one coat of anti-Creosote paint (internal surface) and Red
oxide paint (external surface).
Same as item 7-80, but 230 mm wall, (Single/Double Leaf). Metre 7-81 1280

Same as item 7-80, but 342 mm wall, (Single/Double Leaf). Metre 7-82 1729

Same as item 7-80, but 18 SWG. Metre 7-83 801


Same as item 7-81, but 18 SWG. Metre 7-84 1095
Same as item 7-80, but 18 SWG. Metre 7-85 1472
Windows / Sashes/CSWs
Supply and fix, 1st Class Soft wood (Deodar), wrought, Sqm 7-86 12024
sashes, glazed with moulded or chamfered bars, panels filled
in with glass including chowkats, holdfasts and fixed with
screws to frames, 32 mm thick.
Same as item 7-86, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-87 11981
Same as item 7-86, but 38 mm thick, glazed. Sqm 7-88 12412
Same as item 7- 88, but wire gauzed, 9x9 mesh, 24 gauge. Sqm 7-89 12391

Deduct from item 7-86 to 7-89, if chowkats not supplied and 7-90 7250
fixed.
Supply and fix, 1st Class Hard wood (Sheesham), wrought, Sqm 7-91 10716
sashes, glazed with moulded or chamfered bars, panels filled
in with glass including chowkats, holdfasts and fixed with
screws to frames, 32 mm thick.

Same as item 7-91, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-92 10981
Same as item 7-91, but 38 mm thick, glazed. Sqm 7-93 10716
Same as item 7-93, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-94 10693
Deduct from item 7-91 to 7-94, if chowkats not supplied and Sqm 7-95 5410
fixed.
Supply and fix, 1st class Soft wood (Deodar), CSWs glazed, Sqm 7-96 15605
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with pivots and
mongery all as specified, 32 mm thick.
Same as item 7-96, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-97 15588
Same as item 7-96, but 38 mm thick. Sqm 7-98 15875
Same as item 7-98, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-99 15926
Deduct from item 7-96 to 7-99, if chowkats not supplied and Sqm 7-100 10924
fixed.
Supply and fix, 1st class Hard wood (Sheesham), CSWs glazed Sqm 7-101 11217
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with pivots and
mongery all as specified, 32 mm thick.
Same as item 7-101, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-102 11200
Same as item 7-101, but 38 mm thick. Sqm 7-103 11486
Same as item 7-103, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-104 11395
Deduct from item 7-101 to 7-104, if chowkats not supplied Sqm 7-105 7048
and fixed.
Deduct from item 7-97, 7-99, 7-102 and 7-104, if mosquito Sqm 7-106 409
proof gauze is used.
Supply and fix, Venetian shutter for windows made of 1st Sqm 7-107 13512
class Soft wood (Deodar), 100 mm wide rail and styles and
Hard wood (Sheesham) Venetian, including chowkats 75 mm
x 125 mm, holdfasts and fixed with screws to frame, 32 mm
thick.
Same as item 7-107, but 38 mm thick. Sqm 7-108 14301
Deduct from item 7-107 and 7-108, if chowkats 1st class Soft Sqm 7-109 6325
wood (Deodar) not supplied and fixed.
Aluminium Windows
Supply of Aluminium Sliding window, Deluxe Quality, of Sqm 7-110 8567
Anodized Aluminium extruded section in any size, colour and
texture as specified, including fixing on concrete, wood or
steel frames, complete with all necessary fittings except glass.

Same as item 7-110 but Premium Quality. Sqm 7-111 8927


Supply of Aluminium Fixed window, Deluxe Quality, of Sqm 7-112 6527
Anodized Aluminium extruded section in any size, colour and
texture as specified, including fixing on concrete, wood or
steel frames, complete with all necessary fittings except glass.

Same as item 7-112 but Premium Quality. Sqm 7-113 6895


Supply of Aluminium Side Hung window, Deluxe Quality, of Sqm 7-114 7727
Anodized Aluminium extruded section in any size, colour and
texture as specified, including fixing on concrete, wood or
steel frames, complete with all necessary fittings except glass.

Same as item 7-114 but Premium Quality. Sqm 7-115 8095


Steel Windows
Supply and fix, Box type steel sliding/fixed window or CSW Sqm 7-116 6759
using 16 gauge frame section 75 mm x 30 mm and panel
section 25 mm x 50 mm and 10 mm x 10 mm square gola,
with all necessary steel fitting / mongery hold fast etc. and
two coats of SE paint in addition to one coat of primer/ rust
proof paint, except glass panes, grill and wire gauze.

Supply and fix, Box Pipe type open-able and fixed side-hung Sqm 7-117 7289
window or CSW using 16 gauge frame section 50mm x 25mm
and panel Z shape 38 mm x 31 mm x 38 mm and 10mm x
10mm square gola, not exceeding 1.48 Sqm each, with all
necessary fittings/mongery, hold fast etc. and two coats of SE
paint in addition to one coat of primer / rust proof paint,
except wire gauze and glass panes and grill.

Same as item 7-117 but exceeding 1.48 Sqm, all as specified. Sqm 7-118 7287

uPVC Windows
Supply and fix uPVC sliding window in white colour 37 mm Sqm 7-119 10843
thick shutter with , frame 80 mm x 50 mm complete
exceeding 2.23 Sqm each in white colour including necessary
fittings, mongery, fly proof netting, except glass.

Same as item 7-119, but coloured. Sqm 7-120 19894


Supply and fix, uPVC open able window, 60 mm thick shutter Sqm 7-121 11986
with frame complete, exceeding 2.23 sqm each in white
colour including necessary fittings, mongery, except glass.

Same as item 7-121, but coloured. Sqm 7-122 19127


Supply and fix, uPVC 37mm thick fixed window, with frame Sqm 7-123 7578
complete exceeding 2.23 sqm each, in white colour including
necessary fittings, mongery except glass.

Same as item 7-123, but coloured. Sqm 7-124 12010


Partitions
Supply and fix, 1st Class Soft Wood (deodar) framed and Sqm 7-125 6732
panelled partitions and dados, 32 mm thick.
Same as item 7-125, but 38 mm thick. Sqm 7-126 7101
Supply and fix, 1st Class Hard Wood (Sheesham) Framed and Sqm 7-127 6017
Panelled partitions and dados, 32 mm thick.

Same as item 7-127, but 38 mm thick. Sqm 7-128 6340


Supply and fix, 1st Class Hard wood (Ash Wood) framed and Sqm 7-129 10621
panelled partitions and dados 32 mm thick all as specified.

Same as item 7-129 but 38 mm thick all as specified. Sqm 7-130 11357
Supply and fix,1st Class Hard wood (Mohagany), framed and Sqm 7-131 10466
panelled partition and dados 32 mm thick, all as specified.

Same as item 7-131 but 38 mm thick all as specified. Sqm 7-132 11189
Supply and fix,12mm thick Plate Glass partition/door in any Sqm 7-133 10316
size including all necessary accessories i.e. pivot machine,
handle lock etc.
Kitchen Cabinets
Supply and fix, Kitchen Floor / Sink Floor Cabinet, 600 mm Metre 7-134 14209
wide and 862 mm high with First Class Soft wood (Deodar)
frame, 19 mm thick Teak Veneered board shutter, drawers
including all necessary Chromium plated (CP) mongery, RCC
slab, 25 mm thick white / coloured marble slab, complete as
per IS Arch 17,18 and 19.

Supply and fix, Kitchen Wall Cabinet 381mm wide and 610 Metre 7-135 7596
mm high, 19 mm thick Teak Veneered board shutter
complete as per IS Arch 17, 18 and 19, including all necessary
CP monger, fixture and deodar wood edging provided to door
cabinets.
Supply and fix, Kitchen Exhaust Hood made of Teak Veneered Metre 7-136 6721
board with 22BG, PGI sheet fixed on inner side complete as
per Information Sheet IS Arch No 17, 18 and 19, including all
fitting / fixture as specified.
Venetian Blinds
Supply and fix, Venetian blinds (Horizontal) having metallic, Sqm 7-137 2193
plastic strip, upto 25mm width, complete with all accessories.

Supply and fix, Venetian blind (Vertical) having fabric strip, Sqm 7-138 3691
upto 90 mm width, of desired shades, complete with all
accessories.
Same as item 7-138, but strip width exceeding 90mm upto Sqm 7-139 4078
127 mm.
Supply any fix, Venetian blinds (horizontal) having wooden Sqm 7-140 4338
strip, complete with all accessories.
Wire Gauze
Supply Iron tinned wire gauze fly proof 9x9 mesh, 24 gauge Sqm 7-141 1435
and fixed with cover fillets to window chowkats etc.

Same as item 7-141, but 22 gauge. Sqm 7-142 1543


Same as item 7-141 or 7-142, but except cost of wire gauze. Sqm 7-143 608

Add to item 7-141 to 7-143, if fixed in repairs. Sqm 7-144 111


Supply of Iron tinned wire gauze mosquito proof 18 x 18 Sqm 7-145 822
mesh, 28 gauge and fixed with cover fillets to window
chowkats etc.
Same as item 7-145, but except cost of wire gauze. Sqm 7-146 527
Add to item 7-145 or 7-146, if fixed in repairs. Sqm 7-147 111
Supply Iron tinned wired gauze fly proof 9 x 9 mesh, 22 gauge Sqm 7-148 1468
and fixed with flat iron 13 mm x 3 mm to steel window
frames with screws 75 mm c/c, complete.
Same as item 7-148, but 24 gauge. Sqm 7-149 1359
Same as item 7-148 or 7-149, but except cost of wire gauze. Sqm 7-150 528

Add to item 7-148 or 7-149 or 7-150, if fixed in repairs. Sqm 7-151 71


Supply of Iron tinned wire gauze, 18 x 18 mesh, 26 gauge and Sqm 7-152 744
fixed with flat iron 13 mm x 3 mm to steel window frames
with screws 75 mm c/c complete.
Same as item 7-152, but except cost of wire gauze. Sqm 7-153 528
Add to item 7-152 or 7-153, if fixed in repairs. Sqm 7-154 71
Supply of Aluminium wire gauze 16x16 mesh, 26 gauge and Sqm 7-155 1141
fixed with flat iron 13 mm x 3 mm to steel window frames
with screws 75 mm c/c, complete.
Same as item 7-155, but except cost of wire gauze. Sqm 7-156 528
Add to item 7-155 or 7-156, if fixed in repairs. Sqm 7-157 71
Supply of Aluminium fly/ insects screening with mesh (Deluxe Sqm 7-158 4555
and premium model), of Anodized extruded section including
fixing on concrete, wood or steel frames with all necessary
fittings, complete all as specified.

Same as item 7-158 but fixing only. Sqm 7-159 33


Jobbing works
Re-securing without taking down window chowkats including Each 7-160 248
window boards, if any, (Hard/Soft wood).
Taking down window chowkats including window boards, if Each 7-161 436
any, (Hard/Soft wood) and refixing in same opening.

Same as item 7-161, but refixing in other opening. Each 7-162 523
Taking down window chowkats including window boards, if Each 7-163 105
any, (Hard/Soft wood).
Removing to or from store window chowkats including Each 7-164 69
window boards, if any, (Hard/Soft wood).
Re-securing without taking down window chowkats including Each 7-165 175
Sashes (Hard/Soft wood).
Taking down window chowkats including sashes (Hard/Soft Each 7-166 415
wood) and re-fixing in same opening.
Same as item 7-166, but re-fixing in other opening. Each 7-167 601
Taking down window chowkats, including sashes (Hard/Soft Each 7-168 62
wood).
Removing to or from store, window chowkats including Each 7-169 40
sashes (Hard/Soft wood).
Re-securing without taking down casement window fanlights Each 7-170 122
etc. (sashes only) (Hard/Soft wood).
Taking down casement, window, fanlights etc. (sashes only) Each 7-171 229
(Hard/Soft wood) and re-fixing same opening.
Same as item 7-171, but re-fixing in other openings. Each 7-172 275
Taking down casement, windows, fanlights etc. (sashes only), Each 7-173 53
Hard /Soft wood.
Removing to or from store, casement, window, fanlights etc. Each 7-174 20
(sashes only) Hard/ Soft wood.
Re-securing without taking down door chowkats (not Each 7-175 249
exceeding 2.60 m each) including architraves if any,
(Hard/Soft wood).
Taking down door chowkats (not exceeding 2.60 m each) Each 7-176 415
including architraves if any, Hard/Soft wood and refixing in
same opening.
Same as item 7-176, but re-fixing in other opening. Each 7-177 506
Taking down door chowkats (not exceeding 2.60 m each) Each 7-178 125
including architraves, if any, Hard/Soft wood.
Removing to or from store door chowkats (not exceeding Each 7-179 50
2.60 m super each) incl architraves, if any, Hard/Soft wood.

Re-securing without taking down door chowkats (exceeding Each 7-180 436
2.60m each) including architraves if any, Hard/Soft wood.

Taking down door chowkats (exceeding 2.60m each) Each 7-181 601
including architraves if any, Hard / Soft wood and re-fixing in
same opening.
Same as item 7-181, but re-fixing in other opening. Each 7-182 634
Taking down door chowkats (exceeding 2.60 m each) Each 7-183 270
including architraves if any, Hard /Soft wood.
Removing to or from store, door chowkats (exceeding 2.60 m Each 7-184 83
each) including architraves if any, Hard /Soft wood.

Re-securing without taking down door or gates, leaves only Each 7-185 56
(single or folding) of any pattern or thickness not exceeding
2.60 m each, Hard /Soft wood.
Taking down door or gates, leaves only (single or folding) of Each 7-186 146
any pattern or thickness not exceeding 2.60 m each, Hard /
Soft wood and re-fixing in same opening.

Same as item 7-186, but re-fixing in the other opening. Each 7-187 201
Taking down door or gates, leaves only (single or folding) of Each 7-188 55
any pattern or thickness not exceeding 2.60 m each.

Removing to or from store door or gates, leaves only (single Each 7-189 30
or folding) of any pattern or thickness exceeding 2.60 m
each. Hard / Soft wood.
Re-securing without taking down partitions, framing, Sqm 7-190 125
cupboard front, wall panelling and similar woodwork,
including doors exceeding 2.60 m each, Hard / Soft wood.

Taking down partitions, framing, cupboard front, wall Sqm 7-191 435
panelling and similar woodwork, including doors exceeding
2.60 m each Hard / Soft wood and re-fixing in same opening.

Same as item 7-191, but re-fixing in other opening. Sqm 7-192 1058
Taking down partitions, framing, cupboard front, wall Sqm 7-193 259
panelling and similar woodwork, including doors exceeding
2.60 m each, Hard / Soft wood.
Removing to or from store, partitions, framing, cupboard Sqm 7-194 240
front, wall panelling and similar woodwork, including doors
exceeding 2.60 m each, Hard / Soft wood.

Door or gates (any description) cramped up, reweighed with Each 7-195 666
new wedges in glue (or white lead repined if in external work)
not exceeding 2.60 m each, including taking down and re-
hanging, taking off and re-fixing hinges (any description) and
removing to and from workshop.

Same as item 7-195, but exceeding 2.60 m each. Each 7-196 691
Door or gates (any description) cramped up, reweighed with Each 7-197 728
new wedges in glue (or white lead repined if in external work)
not exceeding 2.60 m each, including taking down and re-
hanging, taking off and re-fixing hinges (any description) and
renewal of defective parts and removing to and from
workshop.
Same as item 7-197, but exceeding 2.60 m each. Each 7-198 1047

Description Unit SI No. Rate (Rs)


Tower Bolts
Supply and fix, 100 mm long, CP tower bolts with bright Each 8-1 146
shoots, and fixed with sockets or let into any material.

Same as item 8-1, but fixing only. Each 8-2 98


Same as item 8-1 to 8-2, if fixed in repairs. Each 8-3 42
Supply and fix, 100 mm long, Brass tower bolts with Brass Each 8-4 274
shoots, and fixed with sockets or let into any material.

Same as item 8-4, but fixing only. Each 8-5 93


Same as item 8-4 or 8-5, if fixed in repairs. Each 8-6 42
Supply and fix 150 mm long, CP tower bolts with bright Each 8-7 196
shoots, and fixed with sockets or let into any material.
Same as item 8-7, but fixing only. Each 8-8 124
Same as 8-7 or 8-8, if fixed in repairs. Each 8-9 53
Supply and fix, 150 mm long, Brass tower bolts with Brass Each 8-10 322
shoots, and fixed with sockets or let into any material.

Same as item 8-10, but fixing only. Each 8-11 117


Add to item 8-10 or 8-11, if fixed in repairs. Each 8-12 53
Supply and fix, 200 mm long, CP tower bolts with bright Each 8-13 242
shoots, and fixed with sockets or let into any material.

Same as item 8-13, but fixing only. Each 8-14 145


Add to item 8-13 or 8-14, if fixed in repairs. Each 8-15 63
Supply and fix, 200 mm long, Brass tower bolts with Brass Each 8-16 476
shoots, and fixed with sockets or let into any material.

Same as item 8-16, but fixing only. Each 8-17 138


Same as item 8-16 or 8-17, if fixed in repairs. Each 8-18 63
Bolts (All Drops)
Supply and fix, 300 mm long CP, sliding and locking bolts with Each 8-19 512
staple (Plate thickness 16- 18 gauge).
Same as item 8-19, but fixing only. Each 8-20 182
Add to item 8-19 or 8-20, if fixed in repairs. Each 8-21 126
Supply and fix, 300 mm long, Brass sliding and locking bolts Each 8-22 1619
with staple (Plate thickness 16 -18 gauge).
Same as item 8-22, but fixing only. Each 8-23 171
Same as item 8-22 or 8-23, if fixed in repairs. Each 8-24 63
Supply and fixing, 450 mm long, CP, sliding and locking bolts Each 8-25 848
with staple (Plate thickness 16 - 18 gauge).
Same as item 8-25, but fixing only. Each 8-26 226
Add to item 8-25 or 8-26, if fixed in repairs. Each 8-27 63
Supply and fix, 450 mm long, Brass sliding and locking bolts Each 8-28 2055
with staple (plate thickness 16 -18 gauge).
Same as item 8-28, but fixing only. Each 8-29 210
Add to item 8-28 or 8-29, if fixed in repairs. Each 8-30 63
Hinges
Supply and fix, hinges, Butt, Steel, 50mm long. Each 8-31 152
Same as item 8-31, but 75 mm long. Each 8-32 224
Same as item 8-31, but 100 mm long. Each 8-33 298
Same as item 8-31, but 125 mm long. Each 8-34 400
Same as item 8-31 to 8-34, if fixing only. Each 8-35 67
Add to item 8-31 to 8-35, if fixed in repairs. Each 8-36 48
Supply and fix, hinges, Butt, Brass, 50 mm long. Each 8-37 194
Same as item 8-37, but 75 mm long. Each 8-38 346
Same as item 8-37, but 100 mm long. Each 8-39 418
Same as item 8-37, but 125 mm long. Each 8-40 640
Same as item 8-37 to 8-40, but fixing only. Each 8-41 60
Add to item 8-37 to 8-41, if fixed in repairs. Each 8-42 48
Supply and fix, hinges, Parliament, Steel, 75mm long. Each 8-43 563
Same as item 8-43, but 100 mm long. Each 8-44 606
Same as item 8-43, but 125 mm long. Each 8-45 171
Same as item 8-43 to 8-45, but fixing only. Each 8-46 51
Add to item 8-43 to 8-46, if fixed in repairs. Each 8-47 42
Supply and fix, CP hinges, 16 mm wide and 1800 mm long Each 8-48 305
(Piano Type).
Same as item 8-48, but 19 mm wide and 1800 mm long Each 8-49 249
(Piano Type).
Same as item 8-48, but 25 mm wide and 1800 mm long Each 8-50 516
(Piano Type).
Same as item 8-48 or 8-49 or 8-50, but fixing only. Each 8-51 184
Add to item 8-48 to 8-51, if fixing in repairs. Each 8-52 42
Supply and fix CP hinges, 25 mm wide and 2025 mm long Each 8-53 538
(Piano Type).
Same as item 8-53, but fixing only. Each 8-54 207
Add to item 8-53 or 8-54, if fixed in repairs. Each 8-55 42
Supply and fix, Brass hinges, 13 mm wide and 1800 mm long Each 8-56 630
(Piano type).
Same as item 8-56, but 16 mm wide and 1800 mm long Each 8-57 684
(Piano type).
Same as item 8-56, but 19 mm wide and 1800 mm long Each 8-58 721
(Piano type).
Same as item 8-56, but 25 mm wide and 1800 mm long Each 8-59 901
(Piano type).
Same as item 8-56 to 8-60, but fixing only. Each 8-60 128
Add to item 8-56 to 8-60, but fixed in repairs. Each 8-61 42
Supply and fix, Brass hinges 25 mm wide and 2025 mm long Each 8-62 1045
(Piano type).
Same as item 8-62, but fixing only. Each 8-63 164
Add to item 8-62 or 8-63, if fixed in repairs. Each 8-64 63
Spring Hinges
Supply and fix, 100mm long, Double action, Brass spring Per set 8-65 1189
hinges.
Same as item 8-65, but 115 mm long. Per set 8-66 1654
Same as item 8-65, but 125 mm long. Per set 8-67 1849
Same as item 8-65, but 150 mm long. Per set 8-68 2036
Same as item 8-65 to 8-68, but fixing only. Per set 8-69 117
Same as item 8-65 to 8-69, if fixed in repair. Per set 8-70 105
Supply and fix, 100mm Brass spring hinges. Each 8-71 527
Same as item 8-71, but 115 mm long. Each 8-72 659
Same as item 8-71, but 125 mm long. Each 8-73 741
Same as item 8-71 to 8-73, but fixing only. Each 8-74 136
Add to item 8-71 to 8-74, if fixed in repairs. Each 8-75 122
Supply and fix, Hydraulic door closer, Standard. Each 8-76 937
Same as item 8-76, but Deluxe. Each 8-77 2472
Same as item 8-76, but fixing only. Each 8-78 231
Add to item 8-76 to 8-78, if fixed in repairs. Each 8-79 147
Latches
Supply and fix, Japanned Pressed Steel latch, 100 mm long Each 8-80 873
strong brass bolt and knob with 2 brass levers.
Same as item 8-80, but fixing only. Each 8-81 194
Add to item 8-80 or 8-81, if fixed in repairs. Each 8-82 42
Locks
Supply and fix, CP lock or latch, 150 mm with two bolts and Each 8-83 798
two levers, in any pattern/shape.
Supply and fix Rim / Alpha lock Standard Quality, all as Each 8-84 1152
specified.
Same as item 8-84 but Deluxe Quality, all as specified. Each 8-85 1629
Same as item 8-84 but Premium Quality, all as specified. Each 8-86 2600

Same as item 8-83 to 8-86, but fixing only. Each 8-87 195
Add to item 8-83 to 8-87, if fixed in repairs. Each 8-88 42
Locks (Cupboards)
Supply and fix, CP locks for cupboard 50 mm, complete. Each 8-89 154

Supply and fix, Brass locks for cupboard 50 mm, complete. Each 8-90 266

Same as item 8-89 to 8-90, but fixing only. Each 8-91 48


Same as item 8-89 to 8-91, if fixed in repair. Each 8-92 42
Catches Spring
Supply and fix, catch spring, Deluxe 50 / 63 mm with Each 8-93 137
projecting ring, and staples or skirting plate (fan light, hung at
bottom opening inwards or hung at top opening outwards).

Same as item 8-93, but Premium. Each 8-94 271


Same as item 8-93 or 8-94, but fixing only. Each 8-95 35
Add to item 8-93 to 8-95, if fixing in repairs. Each 8-96 11
Fastener, Cockspur
Supply and fix, Steel fastener, cockspur medium size, with Each 8-97 117
slot (or staples) for casements.
Same as item 8-97, but Brass. Each 8-98 126
Same as item 8-97 or 8-98, but fixing only. Each 8-99 35
Same as item 8-97 or 8-99, if fixed in repairs. Each 8-100 21
Supply and fix, Steel fastener and stays (casement) 300mm Each 8-101 247
with hinged joint and two plates with studs complete.

Same as item 8-101, but Brass Each 8-102 313


Same as item 8-101 or 8-102, but fixing only. Each 8-103 135
Add to item 8-101 to 8-103, if fixed in repairs. Each 8-104 63
Supply and fix, Steel fastener and stays (casement) 380mm Each 8-105 293
with hinged joint and two plates with studs complete.

Same as item 8-105, but Brass. Each 8-106 253


Same as item 8-105 or 8-106, but fixing only. Each 8-107 132
Same as item 8-105 to 8-107, if fixed in repairs. Each 8-108 63
Supply and fix, Steel studs on plate (when ordered Each 8-109 35
separately).
Same as item 8-109, but Brass. Each 8-110 124
Same as item 8-109 or 8-110, but fixing only. Each 8-111 31
Add to item 8-109 or 8-111, if fixed in repairs. Each 8-112 13
Cleat Hinges
Supply and fix, Cleats, wooden not exceeding 442 cucm, Each 8-113 147
wrought and splayed to doors and windows, including 75mm
pressed steel butt hinges and fixing with screws.

Same as item 8-113, but fixing only. Each 8-114 56


Same as item 8-113 or 8-114, if fixed in repairs. Each 8-115 21
Supply and fix, steel handle bow, 150mm overall. Each 8-116 200
Same as item 8-116, but Brass. Each 8-117 280
Same as item 8-116, but C P. Each 8-118 212
Same as item 8-116 or 8-117 or 8-118, but fixing only. Each 8-119 114
Same as item 8-116 to 8-119, if fixed in repairs. Each 8-120 42
Supply and fix, CP bow handle 250 mm overall for Swing Each 8-121 414
door.
Same as item 8-121, but Brass. Each 8-122 623
Same as item 8-121 or 8-122, but fixing only. Each 8-123 124
Same as item 8-121 to 8-123, if fixed in repair. Each 8-124 42
Supply and fix, CP drawer handle, 75mm grip. Each 8-125 174
Same as item 8-125, but Brass. Each 8-126 170
Same as item 8-125 or 8-126, but fixing only. Each 8-127 72
Same as item 8-125 to 8-127, if fixed in repairs. Each 8-128 32
Supply and fix, CP drawer handle, 100mm over all. Each 8-129 134
Same as item 8-129, but Brass. Each 8-130 182
Same as item 8-129 or 8-130, but fixing only. Each 8-131 72
Same as item 8-129 to 8-131, if fixed in repairs. Each 8-132 32
Supply and fix, CP Flush pattern handle with dished plated Each 8-133 177
75mm grip.
Same as item 8-133, but Brass. Each 8-134 254
Same as item 8-133 or 8-134, but fixing only. Each 8-135 72
Same as item 8-133 to 8-135, but fixed in repairs. Each 8-136 32
Hooks
Supply and fix, CP hat pegs, 125 mm or over. Each 8-137 82
Same as item 8-137, but Brass. Each 8-138 87
Same as item 8-137 or 8-138, but fixing only. Each 8-139 30
Add to item 8-137 to 8-139, if fixed in repairs. Each 8-140 25
Supply and fix, CP hat and coat hooks, 175 mm or over. Each 8-141 132

Same as item 8-141, but Brass. Each 8-142 276


Same as item 8-141 or 8-142, but fixing only. Each 8-143 35
Add to item 8-141 to 8-143, if fixed in repairs. Each 8-144 15
Supply and fix, CP hook for wardrobe (Single), 56 mm long. Each 8-145 97

Same as item 8-145 but Brass. Each 8-146 132


Same as item 8-145 or 8-146, but fixing only. Each 8-147 36
Add as item 8-145 to 8-147, if fixed in repairs. Each 8-148 15
Screws – Wire Pattern
Supply and fix, Brass screw wire pattern, 50 mm. Each 8-149 64
Same as item 8-149 but , 100 mm. Each 8-150 80
Same as item 8-149 but, 150 mm. Each 8-151 126
Same as item 8-149 to 8-151 but fixing only. Each 8-152 32
Add to item 8-149 to 8-152, if fixed in repairs. Each 8-153 15
Knobs
Supply and fix, Steel knobs 30 mm for cupboard having Each 8-154 97
screwed end.
Same as item 8-154, but fixing only. Each 8-155 25
Add to item 8-154 or 8-155, if fixed in repairs. Each 8-156 13
Supply and fix, Brass knob 30 mm for cupboard with nut Each 8-157 146
screw and rose.
Same as item 8-157, but CP. Each 8-158 122
Same as item 8-157 or 8-158, but fixing only. Each 8-159 25
Add to item 8-157 or 8-158 or 8-159, if fixed in repairs. Each 8-160 13
Supply and fix, Brass knob 70 mm with screws bolt and nut Each 8-161 146
for front doors.
Same as item 8-161, but CP. Each 8-162 133
Same as item 8-161 or 8-162, but fixing only. Each 8-163 25
Add to item 8-161 to 8-163, if fixed in repairs. Each 8-164 13
Supply and fix, Wooden knob 50 mm or 56 mm having Each 8-165 82
polished hard wood tapped end with screws.
Same as item 8-165, but fixing only. Each 8-166 25
Add to items 8-165 or 8-166, if fixed in repairs. Each 8-167 13
Hasp and Staple
Supply and fix, CP Hasp and Staple, hinged to plate overall Each 8-168 176
length 100mm.
Same as item 8-168, but Brass. Each 8-169 182
Same as item 8-168 or 8-169, but fixing only. Each 8-170 67
Add to item 8-168 to 8-170, if fixed in repairs. Each 8-171 53
Spring For Doors
Supply and fix, 150 mm Helical steel spring for doors. Each 8-172 461
Same as item 8-172, but Brass. Each 8-173 552
Same as item 8-172, but CP. Each 8-174 411
Same as item 8-172 to 8-174, but fixing only. Each 8-175 98
Add to item 8-172 to 8-175, if fixed in repairs. Each 8-176 42
Turns - Cupboards
Supply and fix, Brass knob 40mm dia with rose spindle turns Each 8-177 191
and screws.
Same as item 8-177, but CP. Each 8-178 181
Same as item 8-177 or 8-178, but fixing only. Each 8-179 84
Add to item 8-177 to 08-179, if fixed in repairs. Each 8-180 42
Poles for Curtains etc.
Supply and fix, 1st class Soft wood (Deodar) ends 75 mm to Each 8-181 260
100 mm square for curtain poles including steel screws etc.

Supply and fix of 25 mm dia stainless steel pipe with any Metre 8-182 240
colour, design and texture fancy type for curtains with
brackets, ends, hooks etc. complete.
Same as item 8-181 to 8-182, but fixing only. Each 8-183 83
Add to item 8-181 to 8-183, if fixed in repairs. Each 8-184 50
Supply and fix, brackets strong cast Brass for curtain poles of Pair 8-185 785
any dia.
Same as item 8-185, but fixing only. Pair 8-186 90
Add to item 8-185 or 8-186, if fixed in repairs. Pair 8-187 42
Supply and fix Ring type curtain rods with suitable brackets Metre 8-188 203
and end fittings, complete all as specified.
Push and Kick Plates
Supply and fix, Brass or Copper push plate exceeding 160 Each 8-189 544
sqcm in area (16-18 gauge).
Same as item 8-189, but Stainless steel. Each 8-190 364
Same as item 8-189, but CP. Each 8-191 362
Same as item 8-189 to 8-191, but fixing only. Each 8-192 61
Add to item 8-189 to 8-192, if fixed in repairs. Each 8-193 25
Supply and fix, Brass or Copper kick plate (16-18 gauge). Sqm 8-194 9931

Same as item 8-194, but Stainless Steel. Sqm 8-195 3112


3ame as item 8-194, but CP. Sqm 8-196 6886
Same as item 8-194 to 8-196, but fixing only. Sqm 8-197 276
Add to item 8-194 to 8-197, if fixed in repairs. Sqm 8-198 222
Knob Lock
Supply and fix, knob lock CP, 150 mm long. Each 8-199 380
Same as item 8-199, but fixing only. Each 8-200 224
Add to item 8-199 or 8-200, if fixed in repairs. Each 8-201 32
Aluminium / uPVC Door Lock and Closer
Supply and fix, Aluminium door lock, Standard model, Each 8-202 415
Anodized Bronze.
Same as item 8-202 but Deluxe model. Each 8-203 457
Same as item 8-202 but Premium model. Each 8-204 608
Supply and fix, Aluminium door closer, Deluxe Model, Each 8-205 2658
Anodized Bronze.
Same as item 8-205 but Premium model. Each 8-206 3020
Supply and fix, Floor Concealed Door Closer (swing machine, Each 8-207 12197
single/double action), for door width upto1250mm with load
bearing range upto 150 kg, all as specified.

Supply and fix Aluminium door Handle, Anodized bronze in Each 8-208 525
any design and pattern.
Supply and fix uPVC door hinges, all as specified. Each 8-209 4431
Supply and fix uPVC door handle, all as specified. Each 8-210 1058
Supply and fix uPVC door lock, all as specified. Each 8-211 5025
Door Stopper/Linings
Supply and fix, rubber linings to door with screw etc. Metre 8-212 134
Supply and fix, Magnetic door stopper on wall or floor of any Each 8-213 202
type.

Description Unit SI No. Rate (Rs)


Structural Steel Works
Supply and fix, joist, channel, angle or tee sections, fixed Kg 9-1 159
independently without connecting plates etc., cut to ordinary
length.
Same as item 9-1, but erection only. Kg 9-2 12
Add to item 9-1 or 9-2, if fixed in repairs. Kg 9-3 7
Supply and fix purlins, hips and the like, main and cross Kg 9-4 167
beams or grids with angle cleats or other connecting plates,
cut to dead length where required.
Same as item 9-4, but erection only. Kg 9-5 16
Add to item 9-4 or 9-5, if fixed in repairs. Kg 9-6 10
Supply and fix, built up girders, ordinary and compound Kg 9-7 167
stanchion for wheel runs, platforms, gate/door coverings
including screws bolts and nuts etc., or welding etc.

Same as item 9-7, but erection only. Kg 9-8 16


Add to item 9-7 or 9-8, if fixed in repairs. Kg 9-9 10
Supply and fix, roof trusses, framed structure, walls, pieces, Kg 9-10 181
purlins, cleats, etc. and all connections including welding etc.

Same as item 9-10, but erection only. Kg 9-11 30


Add to item 9-10 or 9-11, if fixed in repairs. Kg 9-12 18
Supply and fix, framed stair cases, framed doors and gates Kg 9-13 206
prepared for attachment of coverings including hooks, hinges
sliding or hanging door fittings, fastenings (except locks),
hanging and fixed complete. (Coverings to be paid extra as
supply and fix) including welding in lieu of bolting etc.

Same as item 9-13, but erection only. Kg 9-14 38


Same as item 9-13 or 9-14, if fixed in repairs. Kg 9-15 23
General Steel Works
Supply and fix, holds fast, guard bars, straps or wooden Kg 9-16 237
trusses, holding down bolts with washers, ladders, railing,
brackets, pipe supports, tie rods and balusters, chimney bars,
chains, rings shackles, hinges any type, gratings or gullies,
etc., including forging, letting into stone or brick work etc.
complete by welding in lieu of bolting etc.

Same as item 9-16, but erection only. Kg 9-17 70


Same as item 0-16 or 0-17, if fixed in repairs. Kg 9-18 42
Supply and fix Wind ties including punching and fixing in any Kg 9-19 188
position complete.
Same as item 9-19, but erection only. Kg 9-20 41
Same as item 9-19 or 9-20, if fixed in repairs. Kg 9-21 25
Supply and fix, guard bars, grills, railing, ladders brackets, Kg 9-22 221
hooks hold fasts and frames etc., cut to dead length, reduced
to size, shape, figure etc., including punching/drilling holes if
necessary and fixing, assembling by welding or with the use
of bolts, nuts, rivets washers etc., and erection/fixing in
position including making good the disturbed surface.

Same as item 9-22, but erection only. Kg 9-23 64


Add to item 9-22 or 9-23, if fixed in repairs. Kg 9-24 38
Supply and fix, small articles, weighing under 1 Kg, hammered Kg 9-25 325
from the anvil, heated if necessary, reduced to any size or
figure required, including drilling, punching, welding and
roughly filled if necessary (Articles which cannot be measured
but can only be weighed).

Same as item 9-25, but weighting 1 Kg and over, upto 3 Kg. Kg 9-26 255

Same as item 9-25 or 9-26, but erection only. Kg 9-27 96


Add to item 9-25 or 9-26 or 9-27, if fixed in repairs. Kg 9-28 58
Welding
Gas welding of MS or WI, 9 Sq mm. Metre 9-29 476
Electric welding of MS or WI, 9 Sq mm Screw Bolts. Metre 9-30 180
Supply and fix, bolts not exceeding 10 mm dia and length not Each 9-31 31
exceeding 75 mm, with hexagon, including square, cup or
cheese heads, screwed one washer and one hexagon or
square nut.
Same as Item 9-31, but length exceeding 75 mm and not Each 9-32 36
exceeding 150mm.
Same as item 9-31 or 9-32, but length exceeding 150 mm and Each 9-33 78
not exceeding 300 mm.
Same as item 9-31 or 9-32 or 9-33, but fixing only. Each 9-34 6
Add to item 9-31 to 9-34, if fixed in repairs. Each 9-35 3
Supply and fix, bolts exceeding 10mm, but not exceeding 18 Each 9-36 77
mm dia and length not exceeding 75mm, with hexagon,
square, cup or cheese heads, screwed one or both ends, of
one end enlarged or jagged or lewised, each with one washer
and one hexagon or square nut.

Same as item 9-36, but length exceeding 75mm and not Each 9-37 83
exceeding 150mm.
Same as item 9-36, but length exceeding 150mm and not Each 9-38 114
exceeding 300mm.
Same as item 9-36 or 9-37 and 9-38, but fixing only. Each 9-39 7
Add to item 9-36 to 9-39, if fixed in repairs. Each 9-40 4
Supply and fix, bolts exceeding 18mm but not exceeding 25 Each 9-41 132
mm dia and length not exceeding 75mm with hexagon,
square, cup or cheese heads, screwed one or lewised each
with one washer and one hexagon/square nut.

Same as item 9-41, but length exceeding 75mm and not Each 9-42 216
exceeding 150mm.
Same as item 9-41, but length exceeding 150 mm and not Each 9-43 276
exceeding 300mm.
Same as item 9-41or 09-42 and 09-43, but fixing only. Each 9-44 11
Add to item 9-41 to 9-44, if fixed in repairs. Each 9-45 7
Galvanizing
Galvanizing light articles (weight not exceeding 3 Kg each). Kg 9-46 45

Galvanizing, iron/ steel work (not elsewhere provided) any Sqm 9-47 277
description, area galvanized measure flat (not girths).

Cast Iron (CI) work


Supply and fix, CI work weight not exceeding 6 Kg un- Kg 9-48 437
machined in brackets, gully traps gratings, frames, fire doors,
stop cock boxes, manhole covers and the like.
Same as item 9-48, but weight exceeding 6 Kg. Kg 9-49 462
Supply and fix, CI work weight not exceeding 6kg, machine Kg 9-50 557
turned, as in pulleys etc.
Same as item 9-50, but weight exceeding 6 Kg, as specified. Kg 9-51 687

Steel Reinforcement
Supply and fix, bars round, square or flat including cutting, Kg 9-52 146
bending, binding and placing reinforcement in position.

Same as item 9-52, except cost of bars. Kg 9-53 11


Supply and fix, bars round, using deformed bars Grade-40 Kg 9-54 151
including cutting, bending, binding and placing reinforcement
in position.
Same as item 9-54, except cost of bars. Kg 9-55 11
Supply and fix, bars round, using deformed bars Grade-60, Kg 9-56 154
including cutting, bending, binding and placing reinforcement
in position.
Same as item 9-56, except cost of bars. Kg 9-57 11
Supply and fix, bars round using ribbed, tor steel including Kg 9-58 152
cutting, bending, binding and placing reinforcement in
position.
Same as item 9-58, except cost of bars. Kg 9-59 11
Supply and fix, steel reinforcement for pre-stressed concrete Kg 9-60 361
as in beams, girders etc., including post-tensioning, all as
specified.
Same as item 9-60, except cost of bars. Kg 9-61 70
Add to item 9-52, 9-54, 9-56 and 9-58 for each additional lift Kg 9-62 7
for each storey above 2nd floor roof level, all as specified.

Supply and fix, XPM (expended metal), 38 mm x 44 mm mesh Sqm 9-63 368
(18 gauge) BRC fabric weld-mesh, max-weld etc., in
reinforcement or in other positions like doors, partition and
lathing for plaster, to shape and size as required, including
binding with 14 SWG wire, nails staples etc., and placing in
position, measured net.
Same as item 9-63, but 25 mm x 25 mm mesh. Sqm 9-64 504
Same as item 9-63 but (16 gauge). Sqm 9-65 449
Same as item 9-65 but 25 mm x 25 mm mesh. Sqm 9-66 613
Same as item 9-65 or 9-66, but except cost of fabric etc. Sqm 9-67 95

Plain Sheeting
Supply and fix, GI sheets, 24 BG in walls, floors, ceiling etc. Sqm 9-68 1197

Same as item 9-68, but 22 BG. Sqm 9-69 1442


Same as item 9-68, but 20 BG. Sqm 9-70 1694
Same as item 9-68, but 18 BG. Sqm 9-71 2053
Same as item 9-68 to 9-71, but fixing only. Sqm 9-72 145
Supply and fix, GI sheets 24 BG in hearts, troughs, protection Sqm 9-73 1379
sheets behind stoves, coverings to frames and doors
including edges sleeve pieces, curb to hearths, over wooden
cores, edges mangers etc.
Same as item 9-73, but 22 BG. Sqm 9-74 1640
Same as item 9-73, but 20 BG. Sqm 9-75 1904
Same as item 9-73, but 18 BG. Sqm 9-76 2267
Same as item 9-73 to 09-76, but fixing only. Sqm 9-77 283
Supply and fix, pipes of Galvanized sheets 20 BG, any dia, Sqm 9-78 1826
welded side joints (fixed length to nearest 15mm)
Same as item 9-78 but 18 BG. Sqm 9-79 2133
Same as item 9-78 and 9-79 but fixing only. Sqm 9-80 276
Supply and fix, cowl, elbows of Galvanized sheets 20 BG, Each 9-81 809
(canister with soot door) bends, taped, oval short pieces for
ranges.)
Same as item 9-81 but 18 BG. Each 9-82 833
Same as item 9-81 and 9-82 but fixing only. Each 9-83 85
Hoop Iron
Supply and fix, hoop iron, 25mm, 18 BG at 0.07 Kg/M in any Metre 9-84 83
position (not elsewhere stated) including laps etc., as
required.
Same as item 9-84, but of galvanized sheets. Metre 9-85 94
Same as item 9-84, but 40 mm, 16 BG at 0.15 Kg/ M. Metre 9-86 108
Wire for Fencing
Supply and fix, barbed wire, galvanized 12 gauge, 2 strands 4 Metre 9-87 91
points barbs at 75 mm apart fixed with staples, nails etc., and
connect up ends complete.
Same as item 9-87, but 14 gauge. Metre 9-88 73
Same as item 9-87 or 09-88, but fixing only. Metre 9-89 49
Restraining and re-securing, barbed wire fixed with staples, Metre 9-90 31
nails etc., and connect up ends complete or taking down and
removing to stores per strand.
Supply and fix, 16 SWG galvanized plain wire in any position. Metre 9-91 15

Same as item 9-91, but 14 SWG. Metre 9-92 17


Same as item 9-91, but 12 SWG. Metre 9-93 22
Same as item 9-91, but 8 SWG. Metre 9-94 32
Same as item 9-91 to 9-94, but fixing only. Metre 9-95 7
Add to item 9-91 to 9-95, if fixed in repairs. Metre 9-96 4
Woven Wire Work etc
Supply and fix, Wire Netting, Iron galvanized 50 mm x 50 mm Sqm 9-97 333
mesh, 14 SWG and fixed with tinned tacks, G.I staples etc., all
as required.
Same as item 9-97 but 40 mm x 40 mm mesh as specified. Sqm 9-98 572

Same as item 9-97 but 25 mm x 25 mm mesh as specified. Sqm 9-99 613

Supply and fix, Wire Netting, Iron galvanized 75 mm x 75 mm Sqm 9-100 383
mesh, 12 SWG and fixed with tinned tacks, G.I staples etc., as
required.
Same as item 9-100 but 50 mm x 50 mm mesh as specified. Sqm 9-101 449

Same as item 9-100 but 40 mm x 40 mm mesh as specified. Sqm 9-102 613

Same as item 9-100 but 25 mm x 25 mm mesh as specified. Sqm 9-103 845

Supply and fix, Wire Netting, Iron galvanized 75 mm x 75 mm Sqm 9-104 481
mesh, 10 SWG and fixed with tinned tacks, G.I staples etc., all
as required.
Same as item 9-104 but 50 mm x 50 mm of mesh as Sqm 9-105 443
specified.
Same as item 9-97 to 9-105, but fixing only. Sqm 9-106 40
Add item 9-97 or 9-106, if fixed in repair. Sqm 9-107 24
Concertina / Razor Wire
Supply and fix, Concertina Wire / Razor wire, single coil, 12 Metre 9-108 482
gauge galvanized wire, loop dia 0.452 to 0.990M, complete,
all as specified.
Same as item 9-108, but fixing only. Metre 9-109 6
Same as item 9-108 and 9-109, if fixed in repairs. Metre 9-110 4
MS Hollow pipe
Supply and fix 1”x1”, MS hollow pipe square, 16 gauge Metre 9-111 387
including welding/ jointing etc.
Same as item 9-111 but 1 ¼”x1 ¼”, all as specified. Metre 9-112 540
Same as item 9-111 but 1 ½”x1 ½”, all as specified. Metre 9-113 616
Same as item 9-111 but 2” x 2”, all as specified. Metre 9-114 700
Same as item 9-111 but 3”x3”, all as specified. Metre 9-115 1313
Supply and fix 1”x1”, MS hollow pipe square, 18 gauge Metre 9-116 424
including welding/ jointing etc.
Same as item 9-116 but 1 ¼”x1 ¼”, all as specified. Metre 9-117 464
Same as item 9-116 but 1 ½”x1 ½”, all as specified. Metre 9-118 530
Same as item 9-116 but 2” x 2”, all as specified. Metre 9-119 588
Same as item 9-116 but 3”x3”, all as specified. Metre 9-120 855
Supply and fix, 1 ½"x 1” MS hollow pipe rectangular, 16 gauge Metre 9-121 565
including welding/ jointing etc.
Same as item 9-121 but 2”x 1 ½", all as specified. Metre 9-122 686
Supply and fix, 1 ½"x 1” MS hollow pipe rectangular, 18 gauge Metre 9-123 488
including welding/ jointing etc.
Same as item 9-123 but 2”x 1 ½", all as specified. Metre 9-124 588
Stainless Steel Hand Railing
Supply and fix, Stainless steel Hand railing using ¾" to 2" Metre 9-125 3639
dia,16 to 18 Gauge pipe with all fittings etc. as per
specifications.

Description Unit SI No. Rate (Rs)


Sheets Roof (With End Laps)
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-1 1495
to timber framing or a purlins, with one and half corrugation
side laps and 150 mm end laps, fixed with screws, fibre and
galvanized, curved or limpet washers at centre not exceeding
380 mm.
Same as item 10-1 but 22 BG, all as specified. Sqm 10-2 1771
Same as item 10-1 and 10-2, but except cost of sheets. Sqm 10-3 129
Sheets Roof (Without End Laps)
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-4 1270
to timber framing or purlins with one and half corrugation
side laps and without end laps fixed with screws fibre and
galvanized, curved or limpet washers at centre not exceeding
380mm.
Same as item 10-4 but 22 BG all as specified. Sqm 10-5 1499
Same as item 10-4 to 10-5 but except cost of sheets. Sqm 10-6 124
Sheets with ‘U’ Bolts including End Laps
Supply and fix corrugated galvanized steel sheet 24 BG, fixed Sqm 10-7 1621
to timber framing or purlins with one and half corrugation
side laps and 150 mm end laps fixed with 'U' bolts 10 mm dia
fibre and galvanized, curved or limpet washers at centres not
exceeding 380 mm.
Same as item 10-7 but 22 BG all as specified. Sqm 10-8 1897
Same as item 10-7 to 10-8, but except cost of sheets. Sqm 10-9 255
Sheets with ‘U’ Bolts Without End Laps
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-10 1396
to timber/steel framing or purlins with one and half
corrugation side laps and without end laps fixed with 'U' bolts
10 mm dia fibre and galvanized, curved or limpet washers at
centres not exceeding 380 mm.

Same as item 10-10 but 22 BG, all as specified. Sqm 10-11 1625
Same as item 10-10 to 10-11, but except cost of sheets. Sqm 10-12 250

Sheet with ‘L’ Hooks


Supply and fix, corrugated galvanized iron (CGI) sheet 20 BG, Sqm 10-13 2104
fixed with 'L' hooks, limpet and bituminous washers end and
side laps.
Same as item 10-13, but 22 BG. Sqm 10-14 1851
Same as item 10-13, but 24 BG. Sqm 10-15 1576
Same as item 10-13, 10-14 and 10-15, but fixing only. Sqm 10-16 209
Aluminum Sheets
Supply and fix, Aluminum sheet, 20 BG, with nails and screws, Sqm 10-17 1689
End and Side laps.
Supply and fix of Aluminum corrugated sheets, 18BG fixed Sqm 10-18 3077
with bolts/ screws etc., all as specified.
Same as item 10-17 and 10-18, but fixing only. Sqm 10-19 129
Extra, for bolting, side laps, any gauge, at 225 mm centres. Sqm 10-20 203

Extra, for bolting, end laps, each corrugation. Sqm 10-21 287
Sloping Pattern Roofs
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-22 2272
complete in all respects with nails, screws, clips etc., in
Sloping pattern roofs, with rolled side joints, plain, 150mm
end laps etc., including wooden battens, 40mm x 50mm for
roll.
Same as item 10-22 but 22 BG, all as specified. Sqm 10-23 2568
Same as item 10-22 to 10-23, but except cost of sheets. Sqm 10-24 840

Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-25 2229
complete in all respects with nails, screws, clips etc., in
Sloping pattern roofs, with rolled side joints, plain, without
end laps, sheets, ridges, hips, valley, gutters etc.

Same as item 10-25 but 22 BG, all as specified. Sqm 10-26 2524
Same as item 10-25 to 10-26, but except cost of sheets. Sqm 10-27 833

Plain Galvanized Sheets


Supply and fix, Plain galvanized steel sheet 24 BG in ridges, Sqm 10-28 2269
hips valleys and straight and stepped flashing roof plates and
sleeve pieces etc., including wooden battens as required.

Same as item 10-28 but 22 BG, all as specified. Sqm 10-29 2595
Same as item 10-28 to 10-29 but except cost of sheets. Sqm 10-30 889

Supply and fix, Plain galvanized steel sheet 24 BG in ridges Sqm 10-31 1691
hips, valleys and straight and stepped flashing, roof plates
and sleeve pieces etc., without wooden battens as required.

Same as item 10-31 but 22 BG, all as specified. Sqm 10-32 2017
Same as item 10-31 to 10-32, but except cost of sheets. Sqm 10-33 311
Supply and fix, Plain galvanized steel sheet 20 BG, in Gutters Sqm 10-34 2721
etc. with rounded edge any pattern, (fixed length girth not
exceeding 450 mm wide) with support of galvanized , 19 mm
x 6 mm strap, spaced not exceeding one meter apart,
including angles outlet, stop ends etc.

Same as item 10-34, but 18 BG all as specified. Sqm 10-35 3270


Dismantling corrugated sheets for repair and re-fixing the Sqm 10-36 110
same with screws.
Same as item 10-36, but hook bolts or 'U' Bolts. Sqm 10-37 165
Single Tile Roofs
Providing and laying, single layer of 300 mm x 150 mm x 50 Sqm 10-38 990
mm Flat brick tiles in roof, jointed and pointed in CM 1:3.

Same as item 10-38, but size of Flat brick tiles Sqm 10-39 882
300mm × 150mm × 38mm.
Supply and fix, single layer of 300mm × 150mm × 50mm, PCC Sqm 10-40 1019
3000 psi, precast tiles on roof, jointed and pointed in CM 1:3.

Insulated Tile Roof


Providing and laying, one layer of 300 mm x 150 mm x 50 mm Sqm 10-41 1437
Flat brick tiles in roof, laid on half bricks on edge forming
space in between, bedded, jointed and pointed in CM 1:3
including 300 mm x 75 mm x 100 mm CC perforated tiles, set
in CM 1:3 all round, including two coats of white washing on
top, complete as shown in Figure 10-1 (Coat of hot bitumen
on the surface forming bed of half brick on the edge, to be
paid separately, if ordered).

Same as item 10-41, but size of flat brick tiles 300 mm x 150 Sqm 10-42 1424
mm x 38mm.
Providing and laying, one layer of 300 mm x 300 mm x 50 Sqm 10-43 1181
mm, PCC 3000 psi, Precast tiles on roof, laid on PCC 3000 psi
precast blocks 75mm x 75mm x 100mm forming space in
between, bedded, jointed and pointed in CM 1:3, and
including 300 mm x 75 mm x 100 mm PCC perforated tiles set
in CM 1:3 all round, two coats of white washing on top
complete as shown in Figure 10-2. (Coat of hot bitumen on
the surface forming bed of CC. Precast block, to be paid
separately, if ordered).

Mud Roofs
Providing and laying Mud plaster 25mm thick and leaping Sqm 10-44 278
over 50mm thick mud on roofs.
Same as item 10-44 but over 75 mm thick mud on roofs. Sqm 10-45 300
Same as item 10-44 but over 125 mm thick mud on roofs. Sqm 10-46 343

Providing and laying Mud plaster 25 mm thick including 3 mm Sqm 10-47 235
leaping on roof or floor.
Providing and laying 3 mm thick leaping on roof or floor. Sqm 10-48 102

Felt Work
Supply and fix, two ply bituminous Felt, in flashing and Sqm 10-49 477
concrete / brick work joint, joint wedged and tucked inside
end joints, stuck with approved bituminous adhesive.

Building Paper
Supply of water proofing building or insulating paper, Sqm 10-50 153
weighing 3.92 Kg per 10 sqm, and fix in any position with 50
mm side and 150 mm end laps and nailing, as described for
Felt.
Bitumen Coating
One coat of bitumen, applied hot on roof @ 0.75 Kg/sqm and Sqm 10-51 172
blinded with sand, at 0.012 cum per sqm (including cleaning
surface).
One coat of water proofing compound, using Bitumen 10/20, Sqm 10-52 150
applied hot @ 4.90 Kg /10sqm.
Same as 10-52, but @ 14.68kg /10sqm. Sqm 10-53 296
One coat of bitumen 10/20, @ 1.46 kg per sqm, blinded with Sqm 10-54 335
sand @ 0.012 cum per sqm.
Same as item 10-54, but @ 2.44 kg/sqm. Sqm 10-55 442
One coat of water proofing primer, cold sticker, (Bituminous Sqm 10-56 122
Emulsion) @ 0.75 Kg/sqm all as specified.
Water Proofing Treatments
Supply and laying, one layer of Polyester Based Roofing Sqm 10-57 653
Bitumen Felt, weighing 16 Kg to 18 Kg /10 Sqm with side lap,
end laps including water proofing bitumen primer 0.50 lit
/Sqm including bitumen sticking coat 10/20 @ 0.95 Kg/Sqm,
bitumen paint coat @ 0.95 Kg/Sqm over bitumen felt, blinded
with 3 mm aggregate @ 0.012 Cum /Sqm, complete all as
specified.

Same as item 10-57, but in double layer. Sqm 10-58 1033


Two coats of Elastomeric Cementitious Water Proofing Sqm 10-59 949
Coating, applied as per manufacturer's instructions, all as
specified.
Providing and laying, 3mm thick Torch Bonding Bituminous Sqm 10-60 1118
Membrane [Poly Propylene (PP) / Poly granular (PG)] with self-
adhesive side lap 75mm, end lap 100 mm, complete as
specified.
Same as item 10-60, but 4 mm thick. Sqm 10-61 1402
Supply and fix, Synthetic Vinyl (PVC) Flexible Membrane, 0.25 Sqm 10-62 258
mm thick with 75-100 mm side laps / end laps, seamed/
welded thermally /chemically, all as per manufacturer's
specification.
Same as item 10-62, but 0.50 mm thick. Sqm 10-63 516
Same as item 10-62, but 1 mm thick. Sqm 10-64 1045
Same as item 10-62, but 2 mm thick. Sqm 10-65 1821
Supply and fix, Poly Extruded board 50 mm thick density 32- Sqm 10-66 1024
35 Kg /m3, fixed on as roof insulation with ship lap edges
having any size of sheet, all as specified.
Providing and laying water proofing textile Geomembrane Sqm 10-67 829
0.25 mm thick.
Providing and laying Crystalline water proofing chemical Sqm 10-68 192
coating on concrete surface at rate of 1 kg/m2 as per
manufacturer specification, described in para 3.6.4 of
Section 3 .
Providing and laying Acrylic based rubberized liquid Sqm 10-69 893
membrane, all as per manufacturer’s specifications.
PVC Sheet Roofing
Supply and fix PVC 5 C twin hollow or single hollow Sqm 10-70 3064
corrugated sheet/ roofing coated weighing not less than 5.38
Kg/Sqm except framing all as specified.
Supply and fix PVC 5 C twin hollow or single hollow Sqm 10-71 4807
corrugated sheet/ roofing translucent weighing not less than
4.842 Kg/Sqm except framing all as specified.
Supply and fix PVC top ridge, hips/ valley and flashing plates Sqm 10-72 3013
etc. complete except framing all as specified.
Supply and fix PVC plain sheet/ roofing embedded (2 mm Sqm 10-73 2470
thick) complete except framing all as specified.

Description Unit SI No. Rate (Rs)


Termite proofing of New buildings with approved chemicals Sqm 11-1 248
except joinery.
Termite proofing of Old buildings with approved chemicals Sqm 11-2 223
except joinery.
Termite proofing of old wooden joinery, with approved Sqm 11-3 101
chemical.

Description Unit SI No. Rate (Rs)


Sub Floors
Providing and laying PCC 1:4:8, laid under floor using crushed Cum 12-1 6482
or broken stones.
Same as item 21-1 but PCC 1:6:12, all as specified. Cum 12-2 5845
Same as item 21-1 but PCC 1:3:6, all as specified. Cum 12-3 7107
Floors
Providing and laying burnt bricks, laid flat, in floors, roofs and Sqm 12-4 738
channels etc. laid, jointed in sand or mud.
Same as item 12-4 but, laid on edge, all as specified. Sqm 12-5 1067
Providing and laying burnt bricks, laid flat, in floors, roofs and Sqm 12-6 971
channels etc., laid, jointed and pointed in CM 1:4.

Same as item 12-6 but, laid on edge, all as specified. Sqm 12-7 1393
Providing and laying burnt bricks, laid flat, in floors, roofs and Sqm 12-8 935
channels, etc. laid, jointed and pointed in CM 1:6.

Same as item 12-8 but, laid on edge, all as specified. Sqm 12-9 1360
Providing and laying, PCC 1:3:6, as in floor, slabs, surface Cum 12-10 7013
finished smooth with neat cement and steel trowel, using
crushed or broken stone for Basement /ground floor.

Same as item 12-10 but PCC 1:2:4, all as specified. Cum 12-11 8139
Providing and laying, PCC 1:3:6 laid in floor, slabs as under Cum 12-12 6225
layer for Terrazzo / tiles top finished, using crushed or broken
stone. (for GF,1st,2nd floor and lower ground /basement 1st,
2nd, 3rd).
Same as item 12-12 but, PCC 1:2:4, all as specified. Cum 12-13 7353
Additional Labour Cost
Add to item 12-10, 12-11, 12-12 and 12-13 labour only for Cum 12-14 39
each storey above 2nd floor.
Paving Stones
Providing and laying, PCC Paving stone, 50 mm thick in Sqm 12-15 861
natural colour, as in floors, drive-way, walk-way etc., any
pattern and any shape, (Hydraulically compressed), laid and
jointed in sand, including 50mm thick sand bed as laying
course, all as specified.
Same as item 12-15 but, PCC Paving stone, 50 mm thick in Sqm 12-16 896
any colour (except natural colour), all as specified.

Providing and laying, PCC Paving stone, 60 mm thick in Sqm 12-17 912
natural colour, as in floors, streets, public parking etc., any
pattern and shape, (Hydraulically compressed), laid and
jointed in sand, including 50 mm thick sand bed as laying
course, all as specified.
Same as item 12-17 but, PCC Paving stone, 60 mm thick in in Sqm 12-18 940
any colour (except natural colour), all as specified.

Providing and laying, PCC Paving stone 80 mm thick, in Sqm 12-19 1120
natural colour, as in floors loading decks, highway petrol
pumps etc., any pattern and shape, (Hydraulically
compressed), laid and jointed in sand, including 50mm thick
sand bed as laying course, all as specified.
Same as item 12-19 but, PCC Paving stone 80 mm thick, in Sqm 12-20 1165
any colour (except natural colour), all as specified.

Dividing Strips In Floor


Supply and fix, 2 mm thick and 40 mm wide aluminium, as Metre 12-21 111
dividing strips, in floors.
Same as 12-21 but 25 mm wide dividing strips. Metre 12-22 110
Supply and fix, 8-10 mm thick and 40 mm wide marble patty, Metre 12-23 92
as dividing strips in floors.
Terrazzo Floors
Providing and laying, 20 mm thick Terrazzo floor using marble Sqm 12-24 884
chips (1:2) with ordinary cement, including cutting and
rubbing (except polishing) (for Basement, GF, FF and 2nd
floor )
Same as item 12-24 but with White/ Coloured cement. Sqm 12-25 1350
Providing and laying, 13 mm thick terrazzo floor, using Sqm 12-26 750
marble chips (1:2) with ordinary Cement including cutting
and rubbing, (except polishing). (for GF, 1st , 2nd floor and
lower ground /basement 1st, 2nd, 3rd).
Same as item 12-26 but with White/ Coloured cement. Sqm 12-27 1053
Providing and laying, 13 mm thick dados, skirting , using Sqm 12-28 825
marble chips (1:2) with ordinary Cement including cutting
and rubbing, including 10mm thick Cement plaster (1:3),
(except polishing). (for GF,1st,2nd floor and lower ground
/basement 1st, 2nd, 3rd).

Same as item 12-28 but with White/ Coloured cement. Sqm 12-29 1115
Add to item12-24 to 12-29 for labuor only above 2nd floor. Sqm 12-30 120

Grinding / rubbing of Terrazzo floor /dado. Sqm 12-31 152


Cleaning and wax polishing of Terrazo floor/ dado. Sqm 12-32 77
Cleaning and chemical polishing of terrazzo floor / Sqm 12-33 168
dado/Marble floors.
Providing and laying of sand cushion under floor. Cum 12-34 1352
Tile Work
Providing and laying Standard quality tiles of any make not Sqm 12-35 3197
exceeding 1600 Sq cm, including setting, jointing and
bonding, complete all as specified.
Same as item 12-35 but Deluxe quality tiles of any make, size Sqm 12-36 3975
exceeding 1600 sq cm but not exceeding 3700 sq cm.

Same as item 12-35 but Premium quality tiles of any make, Sqm 12-37 4378
size exceeding 3700 sq cm.
Providing and laying Standard quality marble tiles (Sunny Sqm 12-38 1451
grey, Badel, Ziarat grey, Sunny white, zebra, Taveera boticina,
Supreme white, Parlino stain boticina, Flower boticina), of
any size, 13 mm thick including setting, jointing , bonding
and chemical polishing, complete all as specified.

Same as item 12- 38 but 20 mm thick. Sqm 12-39 3531


Providing and laying Deluxe quality marble tiles (Fancy Royal Sqm 12-40 2189
boticina, Parlino crystal boticina, Ziarat water shade, Parlino
plane boticina, Parlino micro boticina,Ziarat white), of any
size, 13 mm thick including setting, jointing, bonding and
chemical polishing, complete all as specified

Same as item 12-40 but 20 mm thick. Sqm 12-41 6623


Providing and laying Premium quality marble tiles (Ziarat Sqm 12-42 6712
supreme white), of any size, 13 mm thick including setting,
jointing, bonding and chemical polishing, complete all as
specified.
Same as item 12-42 but 20 mm thick. Sqm 12-43 15434
Providing and laying Standard quality granite tiles (Indus gold, Sqm 12-44 3837
Tropical), of any size, 20 mm thick including setting, jointing,
pointing and chemical polishing complete all as specified.

Same as item 12-44 but Deluxe quality granite tiles (Black, Sqm 12-45 6634
Cobra, Rao silk, Sea green, Chagi pink, Paradizo), all as
specified.
Same as item 12-44 but Premium quality granite tiles (Chilly Sqm 12-46 9927
red, Coffe brown, Gibrana, Baltic brown, Red Rubi, Cherry
pink, Cherry brown), all as specified.
Mosaic Tiles
Providing and laying, Mosaic tiles, 300 mm x 300 mm x 25 Sqm 12-47 1713
mm of white cement, on walls and floors laid, set in CM (1:2)
and joints grouted with white / coloured cement, chemical
polished, complete.
Same as item 12-47 but in ordinary cement. Sqm 12-48 1555
Same as item 12-35 to 12-48 but fixing only. Sqm 12-49 670
Add to item 12-47 to 12-48 for labour only for each storey Sqm 12-50 120
above 2nd floor.
Providing and laying of dry bond, all as specified. Sqm 12-51 132
Pointing
Racking out joints of old floors, roofs etc. with brick laid on Sqm 12-52 141
edges, built in any mortar, including preparing surface for re-
pointing.
Same as item 12-52 but with bricks or tiles laid flat. Sqm 12-53 107
Pointing Flush in CM 1:3, to old or new brick floors laid on Sqm 12-54 305
edge.
Same as item 12-54, but bricks laid flat. Sqm 12-55 197
Three applications of Sodium Silicate on concrete surface. Sqm 12-56 103

Floor Toping
Providing and laying, Floor Toping 50 mm thick with PCC Sqm 12-57 747
3000psi compressive cylindrical strength all as specified (Steel
reinforcement to be paid under Section-9).

Providing and laying, Bond Breaking materials, using 0.102 Sqm 12-58 372
mm thick Polythene film, over normal thickness of concrete
floor.
Providing and laying, Screed bed 50 mm thick on bond Sqm 12-59 1235
breaking material as specified.
PVC Floor Tiles
Supply and fix, PVC Floor Plain / Textured Tiles, 2 mm thick. Sqm 12-60 1449

Same as item 12-60 but 3 mm thick. Sqm 12-61 1780


Same as item 12-60 but 5 mm thick. Sqm 12-62 2467
Supply and fix, PVC Floor Plain / Textured Sheet, 2 mm thick. Sqm 12-63 1648

Same as item 12-63 but 3 mm thick. Sqm 12-64 2312


Supply and fix, Anti-Static Tile, 3 mm thick (Copper strips Sqm 12-65 3246
measured and paid separately).
Carpet / Artificial Wooden/ Laminated Tiles
Supply and fix Carpet Tiles with glue as per manufacturer’s Sqm 12-66 3312
specifications.
Providing and laying artificial wooden / laminated tiles, 8 mm Sqm 12-67 2358
thick, all as specified.
Same as item 12-67 but 12 mm thick. Sqm 12-68 4829
Artificial Stone Facade Tiles
Providing and laying, Artificial Stone facade tiles, of any Sqm 12-69 1306
colour and size, all as specified.
Providing and laying, Gutka facade tiles of any colour and Sqm 12-70 1953
size, all as specified.
Plinth Protection
Providing and laying, 75 mm thick PCC 1:2:4 using crushed Sqm 12-71 541
stones, surface finished, smoothened with cement and steel
trowel, including form work as plinth protection.

Cladding / Panelling (Aluminium, PE, PVDF)


Providing and fixing, Aluminium Cladding upto any height Sqm 12-72 5665
with sheets of any size and shape using 0.5 mm thick
Aluminium sheet, 3 mm thick PE (polyethylene) or 0.5 mm
thick Aluminium sheet PVDF (Poly Vinyl Deni Flouride)
coated, in any colour / texture with framing, complete, all as
specified.
Same as item 12-72 but, using 0.4mm thick Aluminum sheet, Sqm 12-73 4855
3.20 mm thick PE (polyethylene) or 0.4 mm thick Aluminium
sheet PVDF (Poly Vinyl Deni Fluoride) coated, all as specified.

Description Unit SI No. Rate (Rs)


Mud Plaster
Mud Plaster, 19 mm thick including 3mm thick leaping. Sqm 13-1 348
Same as item 13-1 but 25 mm thick, all as specified. Sqm 13-2 430
Cement Plaster
Cement Plaster 1:3, 13 mm thick finished as specified Sqm 13-3 340
(Basement, GF, FF and 2nd floor).
Same as item 13-3 but 1:4, all as specified. Sqm 13-4 322
Same as item 13-3 but 1:6, all as specified. Sqm 13-5 302
Cement Plaster 1:3, 19 mm thick finished as specified Sqm 13-6 447
(Basement, GF, FF and 2nd floor).
Same as item 13-6 but 1:4, all as specified. Sqm 13-7 423
Same as item 13-6 but 1:6, all as specified. Sqm 13-8 397
Rough Cast Plaster 1:2, 6 mm thick using 3mm aggregate, all Sqm 13-9 378
as specified.
Same as item 13-9 but 12 mm thick, all as specified. Sqm 13-10 532
Add to item 13-3 to 13-10 for additional labour above 2nd Sqm 13-11 137
floor.
Deduct from item 13-3 to 13-8 if fair face not required, all as Sqm 13-12 33
specified.
Scraping Plaster
Hacking out Cement Plaster of walls or lathing, racking out Sqm 13-13 158
joints when required, or racking out cement jointing to walls,
roofs or floors of any description, or hacking out concrete to
form key, or dismantling, lathing with or without plaster.

Scraping, Leaping or Mud Plaster, any thickness. Sqm 13-14 38


Filleting exceeding 40 mm but not exceeding 75 mm wide Metre 13-15 62
and upto 50 mm deep, in any position, in CM 1:3.
Same as item 13-15, but exceeding 75 mm and not exceeding Metre 13-16 82
150 mm wide, all as specified.
Forming V-grooves 13mm wide and 10 mm deep in new Metre 13-17 110
plaster.
Forming 13 to 19 mm thick Drip Course 50 mm in cement Metre 13-18 167
plaster CM (1:3), all as specified.
Add to item 13-3 if water proof drying system material mixed Sqm 13-19 562
with cement at the rate of 12% by weight.
Add to item 13-4 if water proof drying system material mixed Sqm 13-20 374
with cement at the rate of 12% by weight.
Add to item 13-5 if water proof drying system material mixed Sqm 13-21 326
with cement at the rate of 12% by weight.
Add to item 13-6 if water proof drying system material mixed Sqm 13-22 749
with cement at the rate of 12% by weight.
Add to item 13-7 if water proof drying system material mixed Sqm 13-23 599
with cement at the rate of 12% by weight.
Add to item 13-8 if water proof drying system material mixed Sqm 13-24 434
with cement at the rate of 12% by weight.

Description Unit SI No. Rate (Rs)


Hard Board Ceiling
Supplying and fix, Hard board sheets not exceeding 4 mm Sqm 14-1 727
thick, fixed in ceiling and partitions with 1st Class Soft wood
(Deodar), beveled edge, cover fillets, 50 mm x 13 mm,
screwed on.
Same as item 14-1, but exceeding 4mm and not exceeding 6 Sqm 14-2 772
mm thick sheet.
Same as item 14-1 or 14-2, but except cost of Hard board Sqm 14-3 382
sheets.
Add to item 14-1, 14-2 and 14-3, if fixed in repair. Sqm 14-4 71
Soft Board Ceiling
Supply and fix, 13 mm thick Soft board sheet, fixed in ceiling Sqm 14-5 940
and partitions, with 1st Class Soft wood (Deodar), beveled
edge, cover fillet, 50 mm x 13 mm, screwed on.

Same as item 14-5, but except cost of Soft board sheet. Sqm 14-6 382

Same as item 14-5 or 14-6, if fixed in repair. Sqm 14-7 71


Supply and fix, 13 mm thick, Chip board sheets, fixed in Sqm 14-8 859
ceilings and partitions, with 1st Class Soft wood (Deodar),
beveled edge, cover fillets, 50 mm x 13 mm, screwed on.

Same as item 14-8, but 20 mm thick. Sqm 14-9 941


Same as item 14-8 or 14-9, but except cost of Chip board Sqm 14-10 392
sheets.
Add to item 14-8 to 14-10, if fixed in repairs. Sqm 14-11 71
Thermopore Ceiling
Supply and fix, Thermopore Tiles, fixed in ceiling, partitions Sqm 14-12 544
and dados etc., all as specified.
Add to item 14-12, if fixed in repair. Sqm 14-13 71
Supply and fix, Thermopore Ceiling, 600 mm x 600 mm x 20 Sqm 14-14 2021
mm tiles, along with Aluminium Tee and Aluminium angle, 25
mm x 25 mm x 1 mm, including hanger clips, jointing clips
and GI wire 14 SWG etc., complete all as specified.

Add to item 14-14, if fixed in repairs. Sqm 14-15 291


Replacement of Thermo-pore Ceiling tiles only, 600 mm x 600 Sqm 14-16 578
mm x 20 mm.
Dampa Ceiling
Supply and fix, Dampa Ceiling, along with necessary Sqm 14-17 3984
components for fixing direct or suspending from the soffit
complete, including provision of opening for light.
Add to item 14-17, if fixed in repairs. Sqm 14-18 729
Fibre Glass Ceiling
Supply and fix, Fibre Glass Ceiling (1200 mm x 600 mm) Sqm 14-19 2379
panels, single ply (not less than 1 mm thick), in any colour /
texture, including Aluminium Tee and angle, 25 mm x 25 mm
x 1 mm, hanger clips, jointing clips and GI 14 SWG wire etc.
complete, including provision of openings for lights.

Same as item 14-19, but 2 mm thick sheet. Sqm 14-20 3224


Same as item 14-19, but 3 mm thick sheet. Sqm 14-21 3979
Add to item 14-19 to 14-21, if fixed in repairs. Sqm 14-22 291
Replacement of Fibre Glass Sheet, single ply, (not less than Sqm 14-23 1038
1mm thick) ceiling panels only , 1200 mm x 600 mm.

Same as item 14-23, but 2 mm thick, Fibre Glass sheet. Sqm 14-24 2143
Same as item 14-23, but 3 mm thick, Fibre Glass sheet. Sqm 14-25 2906
Plaster of Paris (POP) Ceiling
Supply and fix, POP Tiles (600 mm x 600 mm x 20 mm), fixed Sqm 14-26 1211
in ceiling in any design, partitions and dados etc.
Add to item 14-26, if fixed in repairs. Sqm 14-27 291
Supply and fix, POP border, in any shape and design, girth not Metre 14-28 159
exceeding 150 mm, complete.
Same as item 14-28, but girth exceeding 150 mm but not Metre 14-29 221
exceeding 300 mm, complete.
Add to item 14-28 and 14-29, if fixed in repairs. Metre 14-30 30
Gypsum Ceiling
Supply and fix Gypsum sheet 1200 mm x 2400 mm x 12.5 Sqm 14-31 2027
mm thick, including Aluminium Tee and Aluminium angle, 25
mm x 25 mm x 1 mm, including hanger clips, jointing clips
and 14 SWG, GI wire etc., complete.

Same as item 14-31 but, Gypsum Ceiling 600 mm x 600 mm x Sqm 14-32 1571
7.5 mm thick, all as specified.
Add to item 14-31 and 14-32, if fixed in repairs. Sqm 14-33 291
Replacement of Gypsum Tiles only, 1200 mm x 2400 mm x Sqm 14-34 814
12.5 mm thick or 600 mm x 600 mm x 7.5 mm thick.

Mineral Acoustics Ceiling


Supply and fix, Mineral Acoustics Sheet Ceiling, 600 mm x 600 Sqm 14-35 2655
mm x 12 mm thick including Aluminium Tee and Aluminium
angle, framing 25 mm x 25 mm x 1 mm, including hanger
clips, jointing clips and 14 SWG GI wire etc., complete.

Add to item 14-35, if fixed in repairs. Sqm 14-36 291


Replacement of Mineral Acoustic Ceiling 600 mm x 600 mm x Sqm 14-37 2613
12 mm, tiles only.
PVC/uPVC Sheet - Ceiling/Paneling
Supply and fix, PVC/uPVC Sheet Ceiling / Paneling, 1.5 mm Sqm 14-38 2027
thick, as in wall paneling / ceiling (soffit of slab) including
fittings in any size, pattern, shape, colour / texture, complete
all as specified.
MDF Ceiling
Supply and fix, 10 mm thick MDF sheets ceiling, along with Sqm 14-39 2392
hanging arrangements, Aluminium 'Tee' and angle 25 mm x
25 mm x 1 mm, including hanger, clips, jointing clips etc.,
complete all as specified.
Same as item 14-39 but 16 mm thick MDF sheets. Sqm 14-40 2878
Add to item 14-39 and 14-40, if fixed in repairs. Sqm 14-41 291
Replacement of 10 mm or 16 mm thick MDF sheets only. Sqm 14-42 949

Description Unit SI No. Rate (Rs)


Cement Slurry wash, on new /old surface per coat. Sqm 15-1 19
White or Colour wash on new /old surface, 1st Coat. Sqm 15-2 20
Same as item 15-2, but 2nd and subsequent coats. Sqm 15-3 15
Distempering with Poly Vinyl Distemper or equivalent, on Sqm 15-4 61
new or old surface, 1st Coat.
Same as item 15-4, but 2nd and subsequent coats. Sqm 15-5 36
Whitening surface of soft board ceiling etc. with POP on new Sqm 15-6 21
or old surface, 1st Coat.
Same as item 15-6, but 2nd and subsequent coats. Sqm 15-7 16
Removing white / colour wash, distemper, plastic emulsion Sqm 15-8 53
paint and weather resistant paint from plastered / un-
plastered surface.
Tarring
Tarring on any plain surface, one coat. Sqm 15-9 119
Same as item 15-9, but two coats. Sqm 15-10 203
Painting Wood Work
Prime Coat on new wood work such as timber work in ceiling Sqm 15-11 140
timber boarding etc., of any description, as specified.

1st Coat of painting on new or old work such as timber work Sqm 15-12 97
ceiling and timber boarding etc. of any description with
synthetic enamel paint.
Same as item 15-12, but second and subsequent coat. Sqm 15-13 82
Prime coat on new work such as glazed or gauzed window Sqm 15-14 137
and fanlight, as specified.
1st Coat of painting on new or old work such as glazed or Sqm 15-15 114
gauzed window and fanlight, with Synthetic Enamel paint.

Same as item 15-15, but second and subsequent coat. Sqm 15-16 103
Primer Coat on new work such as doors of any type and Sqm 15-17 153
description as specified.
1st Coat of painting to new or old work such as doors of any Sqm 15-18 110
type and description with synthetic enamel paint.

Same as item 15-18, but 2nd and subsequent coat. Sqm 15-19 95
Primer coat on new work such as fillets, framings, skirting and Metre 15-20 13
similar work not exceeding 150 mm in girth as specified.

1st coat of painting on new or old work such as fillets, Metre 15-21 7
framings, skirting and similar work not exceeding 150 mm
girth with Synthetic Enamel Paint.
Same as item 15-21, but second and subsequent coat. Metre 15-22 5
Primer coat on new work such as detached articles not C.No 15-23 682
exceeding 900 Sqcm, as specified.
1st coat of painting on new or old work such as detached C.No 15-24 492
articles not exceeding 900 Sqcm with Synthetic Enamel Paint.

Same as item 15-24, but 2nd and subsequent coat. C.No 15-25 354
Painting Steel and Iron Work
1st Coat of painting on new or old work such as steel doors, Sqm 15-26 87
windows and CSWs of any type and description with
Synthetic Enamel paint.
Same as item 15-26, but 2nd and subsequent coat. Sqm 15-27 61
1st Coat of painting on new or old work such as iron guard Sqm 15-28 67
bars, iron bars gates, railing and similar open work with
Synthetic Enamel paint.
Same as item 15-28, but 2nd and subsequent coat. Sqm 15-29 46
1st Coat of painting on new or old work such as plain and Sqm 15-30 95
corrugated sheets in roofs, partitions etc. with Synthetic
Enamel paint. (measured flat not girthed).
Same as item 15-30, but 2nd and subsequent coat. Sqm 15-31 65
1st Coat of painting on new or old work such as pipes, gutters Metre 15-32 14
and similar work not exceeding 150mm in girth with
Synthetic Enamel paint.
Same as item 15-32, but 2nd and subsequent coat. Metre 15-33 10
1st Coat of painting on new or old work such as detached C.No 15-34 855
articles not exceeding 900 Sqcm with Synthetic Enamel paint.

Same as item 15-34, but 2nd and subsequent coat. C.No 15-35 586
1st Coat of painting on new or old surfaces of any description Sqm 15-36 95
of steel with Red Oxide paint.
Same as item 15-36, but 2nd and subsequent coat. Sqm 15-37 83
1st Coat of painting on new or old work such as iron guard Sqm 15-38 70
bars, iron bar gates, gratings, railings and similar open work,
with Red Oxide paint.
Same as item 15-38, but 2nd and subsequent coat. Sqm 15-39 65
1st Coat of painting on new or old work such as pipes, gutters Metre 15-40 14
and similar work not exceeding 150 mm in girth with Red
Oxide paint.
Same as item 15-40, but 2nd and subsequent coat. Metre 15-41 12
1st Coat of painting of new or old work such as detached C.No 15-42 855
articles not exceeding 900 Sq cm with Red Oxide paint.

Same as item 15-42, but 2nd and subsequent coat. C.No 15-43 750
Aluminium Painting
1st Coat of painting on new or old work such as steel doors Sqm 15-44 95
and window with Aluminium paint.
Same as item 15-44, but 2nd and subsequent coat. Sqm 15-45 67
1st Coat of painting on new or old such as corrugated sheets Sqm 15-46 87
in roofs, partitions, etc., (measured flat and not girthed) with
Aluminium paint.
Same as item 15-46, but 2nd and subsequent coat. Sqm 15-47 71
1st Coat of painting on new or old work such as pipes, Metre 15-48 14
gutters, and similar work not exceeding 150 mm internal dia
with Aluminium paint.
Same as item 15-48, but 2nd and subsequent coat. Metre 15-49 10
1st Coat of painting on new or old work such as detached C.No 15-50 851
articles not exceeding 900 Sq cm with Aluminium paint.

Same as item 15-50, but 2nd and subsequent coat. C.No 15-51 598
Painting on Plastered Walls
Surface preparation (for dampness) by provision of a film Sqm 15-52 101
with Alkali Resisting primer on plastered wall or ceiling.

1st Coat of painting on new or old work such as walls Sqm 15-53 81
including all detached attachment with Plastic Emulsion paint.

Same as item 15-53, but 2nd and subsequent coat. Sqm 15-54 57
1st Coat of painting on new or old pipes, picture rails, dados Metre 15-55 14
etc. 150mm in girth with Plastic emulsion paint.
Same as item 15-55, but 2nd and subsequent coat. Metre 15-56 10
1st Coat of Weather Resistant paint on exterior wall for old Sqm 15-57 158
surface.
1st Coat of Weather Resistant paint on exterior wall on new Sqm 15-58 125
surface.
Same as item 15-57 and 15-58, but 2nd and subsequent coat. Sqm 15-59 93

1st coat of texture paint on any surface complete all as Sqm 15-60 61
specified.
Same as item 15-60 but 2nd and subsequent coat. Sqm 15-61 58
Add to item 15-57 to 15-61; additional labour for 2nd and Sqm 15-62 39
each subsequent storey for painting of exterior surfaces only.

One Coat of painting with varnish on surface of any Sqm 15-63 94


description.
Same as item 15-63 but on linear work not exceeding 150 Metre 15-64 14
mm girth.
Same as item 15-63 but to small detached articles as locks, C.No 15-65 843
latches, soot doors and frames, casement fasteners, etc.

Burning Old Paint


Burning off old paint (or removing by chemicals where Sqm 15-66 92
burning is not allowed).
Washing down old wood work. Sqm 15-67 66
Polishing
Wax polishing to wood work (complete rate). Sqm 15-68 281
Spirit polishing to new wood work (complete rate). Sqm 15-69 201
Same as item 15-69, but old wood work. Sqm 15-70 183
Spirit polishing to sashes glazed or gauzed, new work Sqm 15-71 151
(complete rate).
Same as item 15-71, but old work. Sqm 15-72 137
Matt Lacquer polishing with two coats as per specification. Sqm 15-73 336

Lacquer polish to wood work (complete rate). Sqm 15-74 399


Road Marking
Road Marking paint on any new or old surface by using Sqm 15-75 166
mechanical means, 1st coat.
Same as item 15-75, but 2nd and subsequent coat. Sqm 15-76 121
Providing and spreading of glass sphere on top surface of Sqm 15-77 35
road marking paint.
Runway Marking quick rubber based paint on any new or old Sqm 15-78 788
surface all as specified, 1st coat.
Same as item 15-78 but 2nd and subsequent coat. Sqm 15-79 421
Camouflaging Paint
Camouflaging paint on new or old work, 1st Coat. Sqm 15-80 132
Same as item 15-80, but 2nd and subsequent coat. Sqm 15-81 118
Supply and fix Wallpaper, plain or decorative, best quality, all Sqm 15-82 1851
as specified.
Epoxy Paint
1st Coat of Epoxy Red Oxide Zinc Chromate primer on steel Sqm 15-83 156
surface, new or old work, as specified.
Same as item 15-83, but 2nd and subsequent coat. Sqm 15-84 143
1st Coat of Epoxy finish on steel surface, new or old work, as Sqm 15-85 166
specified.
Same as item 15-85, but 2nd and subsequent coat. Sqm 15-86 143
One Coat of Epoxy protective primer on blast cleaned surface Sqm 15-87 148
of new / old work.
1st Coat of Epoxy Coal tar to concrete or steel work new or Sqm 15-88 191
old work as specified.
Same as item 15-88, but 2nd and subsequent coat. Sqm 15-89 155
1st Coat of Epoxy Concrete Finish, to concrete or plastered Sqm 15-90 187
surface, new / old work as specified.
Same as item 15-90, but 2nd Coat. Sqm 15-91 155
1st Coat of Epoxy finish on steel surface, new or old work, as Sqm 15-92 287
specified.
Same as item 15-92, but 2nd and subsequent coat. Sqm 15-93 251
Filling / Sealing of cracks in concrete or plastered surface, Metre 15-94 114
with Epoxy sand mortar.
Wall Coatings
Wall finish, coat of Acrylic based Marble chips coating (Mesh- Sqm 15-95 799
16 large) 1.00 mm to 2.00 mm thick, in any colour. (No extra
coating of water repellent is required).
Wall finish, coat of Roll-on Wall Coating 1.00 mm thick, Sqm 15-96 907
including a base coat in any colour.
Wall finish, coat of Graffito Wall coating 1.5 mm to 3.00 mm Sqm 15-97 710
thick, in any colour, (straight and swirl).
Wall finish, coat of Venetian grain, Wall coating 1.5 mm to Sqm 15-98 752
3.00 mm thick (straight and girth) in any colour.
Wall Finish, Spray coat (like Zola etc.) single colour, complete Sqm 15-99 348
all as specified.
Same as item 15-99 but multi-colour, complete all as Sqm 15-100 396
specified.
Surface preparation by using putty on plastered wall or Sqm 15-101 59
ceiling to form smooth base for distemper, plastic emulsion
paint etc., all as specified.
Epoxy Painting (Pol Tanks)
Cleaning of fuel tank including removal of settled Lit 15-102 2
material/fuel particles from inner surface all as specified.

Abrasive / Sand Blasting of Fuel Tank for new un-painted (un- Sqm 15-103 779
corroded) steel surface all as specified.
Same as item 15-103 but corroded un-painted steel surface. Sqm 15-104 1147

Same as item 15-103 but previously painted (old work) steel Sqm 15-105 1044
surface.
Primer coat imported (USA or Europe) to steel surface buff or Sqm 15-106 4028
ivory colour, minimum 125 micron dry film thickness,
complete as specified.
Finish coat imported (USA or Europe) to steel surface white Sqm 15-107 1147
colour, minimum 125 micron film thickness complete as
specified.

Description Unit SI No. Rate (Rs)


Glazing
Supply and fix, Plain Sheet glass 3 mm thick, fixed to timber Sqm 16-1 1123
or steel sashes with putty as specified.
Same as item 16-1, but 5mm thick. Sqm 16-2 1523
Supply and fix, Frosted Sheet glass 3 mm thick, fixed to Sqm 16-3 1294
timber or steel sashes with putty as specified.
Same as item 16-3, but 5mm thick. Sqm 16-4 1680
Supply and fix, Tinted Sheet glass 5 mm thick, fixed to timber Sqm 16-5 1680
or steel sashes with putty as specified.
Supply and fix, Milky glass 5 mm thick, fixed to timber or steel Sqm 16-6 2094
sashes with putty as specified.
Supply and fix, Plain Sheet glass 3 mm thick, fixed to timber Sqm 16-7 1208
or steel sashes with hard /soft wood beads and screws as
specified.
Same as Item 16-07, but 5mm thick. Sqm 16-8 1608
Supply and fix, Plate glass 8 mm thick, fixed to timber or steel Sqm 16-9 2666
sashes with Hard /Soft wood beads and screws as specified.

Same as Item 16-9, but 10 mm thick. Sqm 16-10 3593


Same as Item 16-9, but 12 mm thick. Sqm 16-11 4405
Supply and fix, Frosted glass 3 mm thick, fixed to timber or Sqm 16-12 1380
steel sashes with hard /soft wood beads and screws as
specified.
Same as Item 16-12, but 5mm thick. Sqm 16-13 1765
Supply and fix, Tinted glass 5 mm thick, fixed to timber or Sqm 16-14 1765
steel sashes with hard/softwood beads and screws or by the
use of rubber lining.
Same as item 16-14, but 8 mm thick. Sqm 16-15 4164
Supply and fix, Milky glass 5 mm thick, fixed to timber or steel Sqm 16-16 2179
sashes with hard /soft wood beads and screws as specified.

Supply and fix, Double Glazing glass 5 mm thick tinted, fixed Sqm 16-17 2436
to timber or steel sashes with hard/ soft wood beads and
screws or by use of rubber lining.
Supply and fix, Re-inforced glass sheet 5 mm thick, fixed to Sqm 16-18 3839
timber/ steel sashes with hard/ soft wood beeds and screws
etc.
Supply and fix Frosted paper of any design/ pattern over plain Sqm 16-19 1595
glass complete, all as specified.
Hacking Out
Hacking out old broken glass from sashes, remove any Sqm 16-20 473
serviceable portions to store and dispose of rubbish.
Tempering
Tempering to any thickness of glass sheet, all as specified. Sqm 16-21 1949

Glass Blocks
Supply and fix, Glass blocks, size 190 mm x 190 mm x 80 mm, Each 16-22 665
as specified.
Same as item 16-22, but fixing only. Each 16-23 102
Add to item 16-22 and 16-23, if fixed in repairs. Each 16-24 60

Description Unit SI No. Rate (Rs)


Water Closet (WC) and Urinals
Supply and Fix Water Closet (WC) of standard quality, Each 17-1 13604
European pattern complete (coupled) all as specified.
Same as item 17-1 but deluxe quality. Each 17-2 16784
Same as item 17-1 but premium quality. Each 17-3 22832
Same as item 17-1 to 17-3, but fixing only Each 17-4 738
Add to item 17-1 to 17-4, if fixed in repair. Each 17-5 382
Supply and Fix, Water Closet (WC) wall mounted including Each 17-6 16206
fittings / fixtures complete all as specified.
Supply and Fix Flush tank concealed type complete all as Each 17-7 21675
specified.
Supply and Fix, flushing cistern glazed, complete all as Each 17-8 3677
specified, (for replacement/ maintenance only).
Supply and Fix, Water Closet (WC), European pattern only, Each 17-9 4813
complete all as specified, (for replacement/ maintenance
only).
Supply and Fix, WC Asiatic pattern not less than 550 mm with Each 17-10 6667
flushing system complete all as specified.
Same as item 17-10, but fixing only. Each 17-11 738
Add to item 17-10 and 17-11, if fixed in repair. Each 17-12 382
Supply and fix, Urinal comprising basin, flushing cistern, flush Each 17-13 6311
pipe etc. complete all as specified.
Same as item 17-13, but fixing only. Each 17-14 912
Add to item 17-13 and 17-14, if fixed in repair. Each 17-15 464
Supply and fix, Closet Pan only, Asiatic pattern, including Each 17-16 3955
connection complete all as specified.
Same as item 17-16, but fixing only in repair. Each 17-17 872
Supply and fix, Low down plastic flushing cistern, with Each 17-18 2806
connection to flushing pipe etc. complete all as specified.

Same as item 17-18, but fixing only. Each 17-19 366


Sink Scullery
Supply and fix, Sink Scullery of Stainless Steel, with single Each 17-20 8063
drainage board, shallow or deep upto 6000 sqcm, including
all fixing, fittings, accessories etc.
Same as item 17-20 but with double drainage board with Each 17-21 12011
single bowl all as specified.
Same as item 17-20 but with single drainage board, with Each 17-22 9692
double bowl exceeding 6000 sqcm upto 7500 sqcm, all as
specified.
Same as item 17-20 but with double drainage board and Each 17-23 14281
double bowl, exceeding 6000 sqcm upto 9300 sqcm, all as
specified.
Fixing only, of Sink Scullery, single drainage board and single Each 17-24 1603
bowl, including all fittings, accessories etc.
Add to item 17-24, for fix in repair. Each 17-25 464
Fixing only of 17-24 but double drainage board and single Each 17-26 1602
bowl, all as specified.
Add to item 17-26, but if fixed in repairs. Each 17-27 464
Fixing only of 7-23 but double drainage board and double Each 17-28 1654
bowl, all as specified.
Add to item 17-28, if fixed in repairs. Each 17-29 464
Supply and fix, Chromium Plated (CP) shower rose of any dia, Each 17-30 807
fixed or adjustable.
Fixing only, Shower rose. Each 17-31 83
Add to item 17-30, and 17-31, if fixed in repairs. Each 17-32 66
Wash Hand Basin (WHB)
Supply and Fix Wash Hand Basin (WHB) of standard quality, Each 17-33 8278
including pedestal, waste pipe, bolts / bracket and coupling
etc., complete all as specified.
Same as item 17-33 but deluxe quality. Each 17-34 10462
Same as item 17-33 but premium quality. Each 17-35 13444
Fixing only, of WHB, including all fittings, except mixer and Each 17-36 1059
pedestal.
Fixing only, of WHB with pedestal, including all necessary Each 17-37 1059
fittings except Mixer.
Add to item 17-36 to 17-37, if fixed in repair. Each 17-38 464
Supply and Fix, wash hand basin of any colour/ size except Each 17-39 4098
pedestal and mixer, complete all as specified, (for
replacement/ maintenance only).
Supply and Fix, pedestal for wash hand basin in any colour, Each 17-40 2337
complete all as specified, (for replacement/ maintenance
only).
Mirrors
Supply and fix , Mirror, (any shape and pattern, circular, Each 17-41 972
rectangular, oval etc.) upto 2700 sqcm, 5 mm thick, with
plastic frame of any colour edges ground, complete all as
specified.
Same as tem 17-41, but fixing only. Each 17-42 247
Add to Item 17-41 and 17-42, if fixed in repair. Each 17-43 108
Supply and fix, Mirror, (any shape and pattern), 5 mm thick, Sqm 17-44 1727
edges ground, complete all as specified.
Same as item 17-44, but fixing only. Sqm 17-45 460
Same as item 17-44 and 17-45, if fixed in repair. Sqm 17-46 100
Bath Accessories
Supply and fix, Plastic shelf, in any size and shape, with plugs Each 17-47 726
and screws, complete all as specified.
Same as item 17-47, but fixing only. Each 17-48 139
Same as item 17-47 and 17-48, if fixed in repair. Each 17-49 55
Supply and fix, Toilet paper holder, any shape, pattern, size Each 17-50 719
with plugs, screws etc., complete all as specified.
Supply and fix, Corner Shelf in any size, shape with plugs and Each 17-51 2054
screw complete all as specified.
Supply and fix, Soap / sponge tray any shape, pattern and size Each 17-52 497
with plugs, screws etc. complete all as specified.

Same as item 17-52, but Brush holder. Each 17-53 642


Same as item 17-52 to 17-53, but fixing only. Each 17-54 122
Add to item 17-52 to 17-54, if fixed in repairs. Each 17-55 76
Supply and fix, Towel rail, CP, single rod, any pattern, shape Each 17-56 1399
and size with plugs, screws etc. complete all as specified.

Same as item 17-56, but double rod. Each 17-57 1510


Same as item 17-56 to 17-57, but fixing only. Each 17-58 203
Same as item 17-56 to 17-58, if fixed in repairs. Each 17-59 108
Supply and fix, Plastic Bath cabinet, 450 mm x 450 mm x 100 Each 17-60 3524
mm, complete all as specified.
Same as item 17-60, but fixing only. Each 17-61 203
Supply and fix, Bath curtain (1.78 m x1.78 m) with plastic Each 17-62 1117
rings etc. complete all as specified.
Supply and fix, 100 mm dia floor trap, including reducer etc. Each 17-63 2185
complete all as specified.
Supply and fix, Casted Grating CP, 100 mm x 100 mm. Each 17-64 619
Same as item 17-64, but 150 mm x150 mm. Each 17-65 813
Supply and fix, Bottle trap, complete all as specified. Each 17-66 1675
Supply and fix, Plastic float valve, for 15 mm dia pipe Each 17-67 385
complete all as specified.
Supply and fix, Copper float valve, for 20 mm dia pipe Each 17-68 542
complete all as specified.
Supply and fix, Plastic connection with brass, C.P or Each 17-69 135
Aluminium union at both ends, 15mm dia from 300mm to
450mm.
Same as item 17-69, but with plastic union, at both end. Each 17-70 252

Same as item 17-69, but 20 mm dia. Each 17-71 252


Supply and fix, CP Copper connection, with brass union on Each 17-72 542
both ends, 20 mm dia upto 450 mm long.
Supply and fix, Vanity bowl, glazed ware, one hole, with Each 17-73 6307
bottle trap, waste coupling etc. complete all as specified.
(except mixer).
Same as item 17-73, but fixing only. Each 17-74 554
Supply and fix, 25 mm thick, marble slab around vanity Sqm 17-75 3177
bowel, with brackets etc including cutting in any shape with
machine, rubbing, polishing and making the joints water
tight.
Supply and Fix, Toilet shower, 15 mm dia. Each 17-76 1493
Fixing only, Toilet shower , 15 mm dia. Each 17-77 165
Fixing only, Wall shower of any type. Each 17-78 330
Supply and fix, Seat cover. Each 17-79 1532
Supply and Fix, Hydraulic seat cover. Each 17-80 3378
Supply and Fix Accessories bath set plastic consisting of shelf, Each 17-81 7162
towel rail, ring, brush holder, toilet paper holder, soap dish
and mirror, complete as specified.
Same as item 17-81 but CP , complete as specified. Each 17-82 11962
Fixing only Accessories bath set consisting of shelf, towel rail, Each 17-83 1162
ring, brush holder, toilet paper holder, soap dish and mirror,
complete as specified.

Description Unit SI No. Rate (Rs)


Water Tubing – GI / MS
Tube, Water Quality (GI) with all fittings (i.e sockets, bends, Metre 18-1 440
tees, elbows where required) and laid complete in trenches,
(excluding excavation) or fixed to wall, floor (surface or
concealed) and ceiling etc, including caps and plugs as
required 15mm dia (light), supply and fixing.

Same as item 18-1, but 20 mm dia. Metre 18-2 585


Same as item 18-1, but 25 mm dia. Metre 18-3 614
Same as item 18-1, but 32 mm dia. Metre 18-4 732
Same as item 18-1, but 40 mm dia. Metre 18-5 933
Same as item 18-1, but 50 mm dia. Metre 18-6 1173
Same as item 18-1, but 65 mm dia. Metre 18-7 1590
Same as item 18-1, but 80 mm dia. Metre 18-8 1898
Same as item 18-1, but 100 mm dia. Metre 18-9 2498
Tube, Water Quality (GI) with all fittings (i.e. sockets, bends, Metre 18-10 485
tees, elbows where required) and laid complete in trenches
(excluding excavation) or fixed to wall, floor (surface or
concealed) and ceiling etc., including caps and plugs as
required 15mm dia (medium), supply and fixing.

Same as item 18-10, but 20 mm dia. Metre 18-11 613


Same as item 18-10, but 25 mm dia. Metre 18-12 697
Same as item 18-10, but 32 mm dia. Metre 18-13 863
Same as item 18-10, but 40 mm dia. Metre 18-14 980
Same as item 18-10, but 50 mm dia. Metre 18-15 1407
Same as item 18-10, but 65 mm dia. Metre 18-16 1696
Same as item 18-10, but 80 mm dia. Metre 18-17 2215
Same as item 18-10, but 100 mm dia. Metre 18-18 3195
Same as item 18-10, but 150 mm dia. Metre 18-19 5454
Same as item, 18-1 or 18-10, but fixing only. Metre 18-20 114
Same as item, 18-2 or 18-11, but fixing only. Metre 18-21 114
Same as item, 18-3 or 18-12, but fixing only. Metre 18-22 140
Same as item 18-4 or 18-13, but fixing only. Metre 18-23 140
Same as item 18-5 or 18-14, but fixing only. Metre 18-24 142
Same as item 18-6 or 18-15, but fixing only. Metre 18-25 163
Same as item 18-7 or 18-16, but fixing only. Metre 18-26 168
Same as item 18-8 or 18-17, but fixing only. Metre 18-27 168
Same as item 18-9 or 18-18, but fixing only. Metre 18-28 208
Same as item 18-19, but fixing only. Metre 18-29 248
Add to item 18-1, 18-10 or 18-20 if removal only. Metre 18-30 104
Add to item 18-2 or 18-11 or 18-21 if removal only. Metre 18-31 104
Add to item 18-3 or 18-12 or 18-22 if removal only. Metre 18-32 78
Add to item 18-4, 18-13 or 18-23 if removal only. Metre 18-33 78
Add to item 18-5 or 18-14 or 18-24, if removal only. Metre 18-34 93
Add to item 18-6 or 18-15 or 18-25 if removal only. Metre 18-35 106
Add to item 18-7 or 18-16 or 18-26 if removal only. Metre 18-36 106
Add to item 18-8 or 18-17 or 18-27 if removal only Metre 18-37 106
Add to item 18-9 or 18-18 or 18-28 if removal only. Metre 18-38 129
Add to item 18-9 or 18-29 if removal only. Metre 18-39 153
Tubes, Water Quality (GI) with all fittings (i.e sockets, bends, Metre 18-40 7151
tees, elbows, where required) and laid complete in trenches
(excluding excavation) or fixed to walls, ceilings and floors
etc, including caps and plugs as required, 200mm dia (4.8mm
thickness), supply and fixing.

Same as item 18-40 but 6.40 mm thickness, supply and fixing. Metre 18-41 8862

Same as item 18-40 or 18-41, but fixing only. Metre 18-42 302
Add to item 18-40, 18-41 or 18-42 if removal only. Metre 18-43 181
Same as item 18-40 but 250 mm dia. (thickness 4.8mm) Metre 18-44 7855

Same as item 18-44 but 6.40 mm thickness. Metre 18-45 11023


Same as item 18-44, 18-45 but fixing only. Metre 18-46 551
Add to item 18-44 , 18-45 or 18-46 if removal only Metre 18-47 207
Same as item, 18-40 but 300 mm dia (6.4 mm thickness). Metre 18-48 13161

Same as item 18-48 but 7.10 mm thickness. Metre 18-49 17267


Same as item, 18-48, 18-49, but fixing only. Metre 18-50 400
Add to item, 18-48, 18-49 or 18-50 if removal only. Metre 18-51 233
Tube MS Sch 40 without socket (weld less) BS specifications Metre 18-52 509
20 mm dia supply and fixing
Same as item 18-52, but 25 mm dia Metre 18-53 733
Same as item 18-52 , but 32 mm dia Metre 18-54 964
Same as item 18-52, but 40 mm dia Metre 18-55 1138
Same as item 18-52, but 50 mm dia Metre 18-56 1498
Same as item 18-52, but 65 mm dia Metre 18-57 2208
Same as item 18-52, but 80 mm dia Metre 18-58 2928
Same as item 18-52, but 100 mm dia Metre 18-59 4071
Same as item 18-52, but 150 mm dia Metre 18-60 6957
Same as item 18-52, but fixing only Metre 18-61 146
Same as item 18-53, but fixing only Metre 18-62 190
Same as item 18-54, but fixing only Metre 18-63 232
Same as item 18-55, but fixing only Metre 18-64 268
Same as item 18-56, but fixing only Metre 18-65 384
Same as item 18-57, but fixing only Metre 18-66 456
Same as item 18-58, but fixing only. Metre 18-67 672
Same as item 18-59, but fixing only. Metre 18-68 672
Same as item 18-60, but fixing only. Metre 18-69 957
Add to item 18-52 or 18-61 if removal only Metre 18-70 66
Add to item 18-53 or 18-62 if removal only Metre 18-71 71
Add to item 18- 54 or18-63 if removal only Metre 18-72 83
Add to item 18-55 or 18-64 if removal only Metre 18-73 89
Add to item 18- 56 or18-65 if removal only. Metre 18-74 96
Add to item 18- 57 or 18-66 if removal only. Metre 18-75 106
Add to item 18-58 or 18-67 if removal only. Metre 18-76 112
Add to item 18-59 or 18-68 if removal only. Metre 18-77 119
Add to item 18-60 or 18-69 if removal only. Metre 18-78 129
MS – Pipes / Fittings
MS pipe, Water Quality (heavy), 20 mm dia, with all fittings Metre 18-79 490
i.e. sockets, bends, tees, elbows etc where required, laid
complete in trenches, as specified in para 18-1-4 (excluding
cost of excavation), supply and fixing.

Same as item 18-79 but 25 mm dia Metre 18-80 600


Same as item 18-79 but 40 mm dia Metre 18-81 891
Same as item 18-79 but 50 mm dia Metre 18-82 888
Same as item 18-79 but 65 mm dia Metre 18-83 1568
Same as item 18-79 but 80 mm dia Metre 18-84 1806
Same as item 18-79 but 100 mm dia Metre 18-85 2843
Same as item 18-79 but 150 mm dia Metre 18-86 4632
Same as item 18-79 but fixing only Metre 18-87 86
Same as item 18-80 but fixing only Metre 18-88 104
Same as item 18-81 but fixing only Metre 18-89 124
Same as item 18-82 but fixing only Metre 18-90 141
Same as item 18-83 but fixing only Metre 18-91 155
Same as item 18-84 or 18-85 but fixing only. Metre 18-92 173
Same as item 18-86 but fixing only. Metre 18-93 204
Add to item 18-79 or 18-87 if removal only. Metre 18-94 65
Add to item, 18-80 or 18-88 if removal only. Metre 18-95 78
Add to item 18-81 or 18-89 if removal only. Metre 18-96 93
Add to item 18-82 or 18-90 if removal only. Metre 18-97 106
Add to item 18-83 or 18-91 or if removal only. Metre 18-98 116
Add to item 18-84 or 18-85 18-92 if removal only. Metre 18-99 129
Add to item 18-86 or 18-93 if removal only. Metre 18-100 153
Tubes, Steam Quality, without socket (weld-less), BS Metre 18-101 414
Specifications, 15mm dia, supply and fixing.
Same as item 18-101 but 20 mm dia. Metre 18-102 543
Same as item 18-101 but 25 mm dia. Metre 18-103 761
Same as item 18-101 but 40 mm dia. Metre 18-104 1186
Same as item 18-101 but 50 mm dia. Metre 18-105 1529
Same as item 18-101 but 65 mm dia. Metre 18-106 2203
Same as item 18-101 but 80 mm dia. Metre 18-107 2990
Same as item 18-101 but fixing only. Metre 18-108 140
Same as item 18-102 but fixing only. Metre 18-109 181
Same as item 18-103 but fixing only. Metre 18-110 221
Same as item 18-104 but fixing only. Metre 18-111 312
Same as item 18-105 but fixing only. Metre 18-112 389
Same as item 18-106 but fixing only. Metre 18-113 499
Same as item 18-107 but fixing only. Metre 18-114 590
Add to item 18-101or 18-108 if removal only. Metre 18-115 25
Add to item 18-102 or 18-109 if removal only. Metre 18-116 30
Add to item 18-103 or18-110 if removal only. Metre 18-117 35
Add to item 18-104 or 18-111 if removal only. Metre 18-118 40
Add to item 18-105 or 18-112 if removal only. Metre 18-119 54
Add to item 18-106 or 18-113 if removal only. Metre 18-120 74
Add to item 18-107 or 18-114 if removal only. Metre 18-121 74
Prepare surface clean of all dust, dirt etc, of MS pipe 15mm Metre 18-122 59
dia and applying two coats of bitumen solution and then
wrap all around with bitumen paper duly dipped in bitumen
solution with overlap of 100mm (excluding cost of pipe).

Same as item 18-122 but 20 mm dia pipe. Metre 18-123 74


Same as item 18-122 but 25 mm dia pipe. Metre 18-124 90
Same as item 18-122, but 32 mm dia pipe. Metre 18-125 94
Same as item 18-122 but 40 mm dia pipe. Metre 18-126 127
Same as item 18-122 but 50 mm dia pipe. Metre 18-127 154
Same as item 18-122 but 65 mm dia pipe. Metre 18-128 201
Same as item 18-122 but 80 mm dia pipe. Metre 18-129 223
Same as item 18-122 but 100 mm dia pipe. Metre 18-130 282
Same as item 18-122 but 150 mm dia pipe. Metre 18-131 375
Socket - GI
Socket GI, 15 mm dia, supply and fixing. Each 18-132 49
Same as item 18-132 but 20 mm dia. Each 18-133 91
Same as item 18-132 but 25 mm dia. Each 18-134 115
Same as item 18-132, but 32 mm dia. Each 18-135 160
Same as item 18-132 but 40 mm dia. Each 18-136 187
Same as item 18-132 but 50 mm dia. Each 18-137 303
Same as item 18-132 but 65 mm dia. Each 18-138 548
Same as item 18-132 but 80 mm dia. Each 18-139 890
Same as item 18-132 but 100 mm dia. Each 18-140 1310
Same as item 18-132 but 150 mm dia. Each 18-141 4032
Socket Reducing – GI
Socket reducing GI, 20 mm x 15 mm dia, supply and fixing. Each 18-142 79

Same as item 18-142 but 25 x 20 mm dia. Each 18-143 118


Same as item 18-142, but 32 x 25 mm dia. Each 18-144 182
Same as item 18-142 but 40 x 25 mm dia. Each 18-145 215
Same as item 18-142 but 50 x 40 mm dia. Each 18-146 320
Same as item 18-142 but 65 x 50 mm dia. Each 18-147 615
Same as item 18-142 but 80 x 65 mm dia. Each 18-148 1031
Same as item 18-142 but 100 x 80 mm dia. Each 18-149 1673
Same as item 18-142 but 150 x 100 mm dia Each 18-150 4760
Bend GI 45o/ 90o
o o Each 18-151 109
Bend GI 45 / 90 , 15 mm dia, supply and fixing.
Same as item 18-151 but 20 mm dia. Each 18-152 145
Same as item, 18-151 but 25 mm dia. Each 18-153 244
Same as item 18-151, but 32 mm dia. Each 18-154 401
Same as item 18-151 but 40 mm dia. Each 18-155 530
Same as item 18-151 but 50 mm dia. Each 18-156 899
Same as item 18-151 but 65 mm dia. Each 18-157 1661
Same as item 18-151 but 80 mm dia. Each 18-158 2370
Same as item 18-151 but 100 mm dia. Each 18-159 4519
Same as item 18-151 but 150 mm dia. Each 18-160 15737
Elbow – GI
Elbow GI, 15 mm dia, supply and fixing. Each 18-161 55
Same as item 18-161 but 20 mm dia. Each 18-162 82
Same as item 18-161 but 25 mm dia. Each 18-163 177
Same as item 18-161, but 32 mm dia. Each 18-164 195
Same as item 18-161 but 40 mm dia. Each 18-165 249
Same as item 18-161 but 50 mm dia. Each 18-166 432
Same as item 18-161 but 65 mm dia. Each 18-167 734
Same as item 18-161 but 80 mm dia. Each 18-168 1352
Same as item 18-161 but 100 mm dia. Each 18-169 2264
Same as item 18-161 but 150 mm dia. Each 18-170 6819
Same as item 18-132, 18-151, or 18-161 but fixing only. Each 18-171 11

Same as item 18-133, 18-142, 18-152 or 18-162 but fixing Each 18-172 13
only.
Same as item, 18-134, 18-143, 18-153 or 18-163 but fixing Each 18-173 14
only.
Same as item 18-135, 18-144, 18-154 or 18-164 but fixing Each 18-174 9
only.
Same as item 18-136, 18-145, 18-155, or18-165 but fixing Each 18-175 18
only.
Same as item 18-137, 18-146, 18-156 or 18-166 but fixing Each 18-176 23
only.
Same as item, 18-138, 18-147, 18-157, or 18-167 but fixing Each 18-177 24
only.
Same as item 18-139, 18-148, 18-158 or 18-168 but fixing Each 18-178 35
only.
Same as item 18-140, 18-149, 18-159 or 18-169 but fixing Each 18-179 35
only.
Same as item 18-141, 18-150, 18-160 or 18-170 but fixing Each 18-180 42
only.
Add to item 18-132, 18-151,18-161or 18-171 if removal only. Each 18-181 4

Add to item 18-133,18-142, 18-152, 18-162, or 18-172 if Each 18-182 5


removal only
Add to item 18-134, 18-143,18-153, 18-163 or 18-173 if Each 18-183 8
removal only.
Add to item 18-,135, 18-144, 18-154, 18-164 or 18-174 if Each 18-184 6
removal only.
Add to item 18-136, 18-145, 18-155 , 18-165 or 18-175 if Each 18-185 8
removal only
Add to item 18-137, 18-146, 18-156, 18-166, 18-176 if Each 18-186 11
removal only.
Add to item 18-138, 18-147, 18-157, 18-167 or 18-177 if Each 18-187 11
removal only.
Add to item 18-139, 18-148, 18-158, 18-168 or 18-178 if Each 18-188 16
removal only.
Add to item 18-140, 18-149, 18-159, 18-169 or 18-179 if Each 18-189 18
removal only.
Add to item 18-141, 18-150, 18-160, 18-170 or 18-180 if Each 18-190 18
removal only.
Tee Equal - GI
Tee equal GI 15 mm dia, supply and fixing Each 18-191 71
Same as item 18-191 but 20 mm dia. Each 18-192 116
Same as item 18-191 but 25 mm dia. Each 18-193 187
Same as item 18-191 but 32 mm dia. Each 18-194 257
Same as item 18-191 but 40 mm dia. Each 18-195 322
Same as item 18-191 but 50 mm dia. Each 18-196 475
Same as item 18-191 but 65 mm dia. Each 18-197 1133
Same as item 18-191 but 80 mm dia. Each 18-198 1634
Same as item 18-191 but 100 mm dia. Each 18-199 2642
Same as item 18-191 but 150 mm dia. Each 18-200 11044
Tee Reducing - GI
Tee reducing GI, 20x15 mm dia, supply and fixing. Each 18-201 129
Same as item 18-201 but 25 x 20 mm dia Each 18-202 212
Same as item 18-201 but 32 x 15 mm dia Each 18-203 310
Same as item 18-201 but 32 x 25 mm dia Each 18-204 316
Same as item 18-201 but 40 x 25 mm dia Each 18-205 411
Same as item 18-201 but 50 x 40 mm dia Each 18-206 583
Same as item 18-201 but 65 x 50 mm dia Each 18-207 1289
Same as item 18-201 but 80 x 65 mm dia. Each 18-208 2018
Same as item 18-201 but 100 x 80 mm dia Each 18-209 3074
Same as item 18-201 but 150 x100 mm dia Each 18-210 12485
Union Socket – GI
Union socket GI, screwed BSS, 15 mm dia, supply and fixing. Each 18-211 162

Same as item, 18-211 but 20 mm dia. Each 18-212 213


Same as item, 18-211 but 25 mm dia. Each 18-213 284
Same as item 18-211, but 32 mm dia. Each 18-214 395
Same as item, 18-211 but 40 mm dia. Each 18-215 535
Same as item 18-211 but 50 mm dia. Each 18-216 764
Same as item 18-211 but 65 mm dia. Each 18-217 1559
Same as item 18-211 but 80 mm dia. Each 18-218 2072
Same as item 18-211 but 100 mm dia. Each 18-219 3856
Same as item 18-191, 18-201, 18-211 but fixing only. Each 18-220 14
Same as item 18-192, 18-202, 18-212 but fixing only. Each 18-221 17
Same as item 18-193, 18-203, 18-213 but fixing only. Each 18-222 20
Same as item 18-194, 18-204, 18-214 but fixing only Each 18-223 22
Same as item 18-195, 18-205, 18-215 but fixing only Each 18-224 24
Same as item 18-196, 18-206, 18-216 but fixing only. Each 18-225 30
Same as item 18-197, 18-207, 18-217 but fixing only. Each 18-226 31
Same as item 18-198, 18-208, 18-218 but fixing only. Each 18-227 40
Same as item 18-199, 18-209, 18-219 but fixing only. Each 18-228 46
Same as item 18-200, 18-210 but fixing only. Each 18-229 54
Add to item 18-191, 18-201, 18-211 or 18-220 if removal Each 18-230 6
only.
Add to item 18-192, 18-202, 18-212, 18-221 if removal only. Each 18-231 8

Add to item 18-193, 18-203, 18-213, or 18-222 if removal Each 18-232 10


only.
Add to item 18-194, 18-204, 18-214 or 18-223 if removal Each 18-233 11
only.
Add to item 18-195, 18-205, 18-215, 0r 18-224 if removal Each 18-234 12
only.
Add to item 18-196, 18-206, 18-216, or 18-225 if removal Each 18-235 16
only.
Add to item 18-197, 18-207, 18-217 or 18-226 if removal Each 18-236 16
only.
Add to item 18-198, 18-208, 18-218, or 18-227 if removal Each 18-237 19
only.
Add to item 18-199, 18-209, 18-219 or 18-228 if removal Each 18-238 23
only.
Add to item 18-200, 18-210, or 18-229 if removal only. Each 18-239 27

Nipple-GI
Nipple, 15 mm dia, supply and fixing Each 18-240 58
Same as item 18-240, but 20 mm dia Each 18-241 91
Same as item 18-240, but 25 mm dia Each 18-242 110
Same as item 18-240, but 32 mm dia Each 18-243 141
Same as item 18-240, but 40 mm dia Each 18-244 197
Same as item 18-240, but 50 mm dia Each 18-245 304
Same as item 18-240, but 65 mm dia Each 18-246 456
Same as item 18-240, but 80 mm dia Each 18-247 838
Same as item 18-240, but 100 mm dia Each 18-248 1240
Same as item 18-240 but 150 mm dia Each 18-249 4186
Same as item 18-240, but fixing only. Each 18-250 12
Same as item 18-241 but fixing only. Each 18-251 12
Same as item 18-242 but fixing only. Each 18-252 14
Same as item 18-243, but fixing only. Each 18-253 17
Same as item 18-244, but fixing only. Each 18-254 18
Same as item 18-245, but fixing only. Each 18-255 23
Same as item 18-246, but fixing only. Each 18-256 24
Same as item 18-247, but fixing only. Each 18-257 32
Same as item 18-248, but fixing only. Each 18-258 36
Same as item 18-249, but fixing only. Each 18-259 42
Add to item 18-240 or 18-250 if removal only. Each 18-260 6
Add to item 18-241 or 18-251 if removal only. Each 18-261 7
Add to item 18-242 or 18-252 if removal only. Each 18-262 8
Add to item 18-243 or 18-253 if removal only. Each 18-263 9
Add to item 18-244 or 18-254 if removal only. Each 18-264 14
Add to item 18-245 or 18-255 if removal only. Each 18-265 14
Add to item 18-246 or 18-256 if removal only. Each 18-266 14
Add to item 18-247 or 18-257 if removal only. Each 18-267 17
Add to item 18-248 or 18-258 if removal only. Each 18-268 18
Add to item 18-249 or 18-259 if removal only. Each 18-269 24
Check Nut – GI
Check nut GI, 15 mm dia, supply and fixing. Each 18-270 29
Same as item 18-270 but 20 mm dia. Each 18-271 38
Same as item 18-270 but 25 mm dia. Each 18-272 44
Same as item 18-270 but 32 mm dia. Each 18-273 40
Same as item 18-270 but 40 mm dia. Each 18-274 62
Same as item 18-270 but 50 mm dia. Each 18-275 84
Same as item 18-270 but 65 mm dia. Each 18-276 144
Same as item 18-270 but 80 mm dia. Each 18-277 196
Same as item 18-270 but 100 mm dia. Each 18-278 361
Same as item 18-270 but 150 mm dia. Each 18-279 740
Plugs – GI / MS
GI/MS plug screwed BSS, 15 mm dia, supply and fixing. Each 18-280 17
Same as item 18-280 but 20 mm dia. Each 18-281 26
Same as item 18-280 but 25 mm dia. Each 18-282 28
Same as item 18-280 but 32 mm dia. Each 18-283 79
Same as item 18-280 but 40 mm dia. Each 18-284 56
Same as item 18-280 but 50 mm dia. Each 18-285 75
Same as item 18-280 but 65 mm dia. Each 18-286 157
Same as item 18-280 but 80 mm dia. Each 18-287 184
Same as item 18-280 but 100 mm dia. Each 18-288 331
Same as item 18-270 or 18-280 but fixing only. Each 18-289 6
Same as item 18-271 or 18-281 but fixing only. Each 18-290 8
Same as item 18-272 or 18-282 but fixing only. Each 18-291 8
Same as item 18-273 or 18-283, but fixing only. Each 18-292 4
Same as item 18-274 or 18-284 but fixing only. Each 18-293 11
Same as item 18-275 or 18-285 but fixing only Each 18-294 12
Same as item 18-276 or 18-286 but fixing only. Each 18-295 12
Same as item 18-277 or 18-287 but fixing only. Each 18-296 16
Same as item 18-278 or 18-288 but fixing only. Each 18-297 19
Same as item 18-279 but fixing only. Each 18-298 16
Add to item 18-270, 18-280 or 18-289 if removal only. Each 18-299 2
Add to item 18-271, 18-281 or 18-290 if removal only. Each 18-300 4
Add to item 18-272, 18-282 or 18-291 if removal only. Each 18-301 3
Add to item 18-273, 18-283 or 18-292 if removal only. Each 18-302 3
Add to item 18-274 18-284 or 18-293 if removal only. Each 18-303 4
Add to item 18-275, 18-285 or 18-294 if removal only. Each 18-304 5
Add to item 18-276, 18-286 or 18-295 if removal only. Each 18-305 5
Add to item 18-277, 18-287 or 18-296 if removal only. Each 18-306 6
Add to item 18-278, 18-288 or 18-297 if removal only. Each 18-307 8
Add to item 18-279 or 18-298 if removal only. Each 18-308 9
Canvas pipe of 40 mm dia, supply and fixing. Metre 18-309 323
Same as item 18-309, but 50 mm dia. Metre 18-310 361
Same as item 18-309, but 65 mm dia. Metre 18-311 421
Same as item 18-309, but 75 / 80mm dia. Metre 18-312 461
Same as item 18-309 to 18-312 but fixing only. Metre 18-313 86
Add to item 18-309 to 18-312 or 18-313, if removal only. Metre 18-314 65

Bib Cocks – (Brass, Bright)


Bib cock, Brass, CP, fancy type, screwed down, BSS, 15 mm Each 18-315 740
dia,
Supply and fixing.
Same as item 18-315, but with long head. Each 18-316 902
Same as item 18-315, but toilet bib cock (Double). Each 18-317 1334
Same as item 18-315, but Ordinary type. Each 18-318 758
Same as item 18-315, to 18-318, but fixing only. Each 18-319 38
Add to item 18-315 to 18-319, if removal only. Each 18-320 26
CP Nipple 15x150 mm for CP bib cock and shower, supply Each 18-321 278
and fixing.
Same as item 18-321, but 15 x 125 mm. Each 18-322 211
Same as item 18-321, but 15 x 80 mm. Each 18-323 176
Same as item 18-321, but 15 x 50 mm. Each 18-324 109
Same as item 18-321 to 18-324, but fixing only. Each 18-325 38
Add to item 18-321 to 18-324, or 18-325, if removal only. Each 18-326 26

Bath and Lavatory Cocks – (CP)


CP Pillar cock, high neck fancy head, screw down, high Each 18-327 1510
pressure, lettered Hot or Cold, with long screw, shank and fly
nuts, fixed on iron pipe 15mm dia, supply and fixing.

CP Mixer, 15mm dia, fancy head, any pattern and shape, Each 18-328 2425
screw down, high pressure, lettered Hot and cold with long
screw channels and fly nuts complete, supply and fixing.

Same as 18-327 to 18-328, but fixing only. Each 18-329 157


Add to item 18-327, 18-328 or 18-329, if removal only. Each 18-330 114

Stop Cock
Stop cock brass, CP, screw down, high pressure, fancy type, Each 18-331 743
15mm dia, supply and fixing.
Same as item 18- 331 but concealed type. Each 18-332 966
Same as item 18-331, but tee stop cock. Each 18-333 743
Same as item 18-331 to 18-333, but fixing only. Each 18-334 41
Add to item 18-331 to 18-333 or 18-334, if removal only. Each 18-335 26

Water Meters Digital


Electromagnetic smart water meter, 20 mm dia for cold Each 18-336 21648
water +0.1oC, water nominal pressure 16 bar, length 190
mm, threaded ends G-1¼”, R800, LCD, m3 reading, 433 MhZ
wM-Bus & Sensus RF radio protocol, battery life, max 15
years, supply & fixing.
Same as item 18-336, but 25 mm dia length 198 mm Each 18-337 26456
Same as item 18-336, but 40 mm dia length 300 mm Each 18-338 38472
Same as item 18-336, but 50 mm dia length 270 mm Each 18-339 67290
Same as item 18-336 but 65 mm dia, Flow sensor MAG 5100 Each 18-340 360297
W, Length 200 mm for water upto 70oC, Flanged type,
Coating grey, LCD indicator.
Same as item 18-336, but 80 mm dia length 200 mm Each 18-341 384297
Same as item 18-336, but 100 mm dia length 200 mm Each 18-342 408354
Same as item 18-336 to 18-342 but fixing only. Each 18-343 173
Add to item 18-336 to 18-342 or 18-343 if removal only. Each 18-344 121

Valves
Valves, "Peet" pattern, strong gunmetal, high pressure, "Full- Each 18-345 551
way" with iron wheel head, screwed both ends for iron pipe,
15 mm dia, supply and fixing.
Same as item 18-345, but 20 mm dia. Each 18-346 816
Same as item 18-345, but 25 mm dia. Each 18-347 1231
Same as item 18-345, but 40 mm dia. Each 18-348 2111
Same as item 18-345, but 50 mm dia. Each 18-349 3805
Same as item 18-345, but 65 mm dia. Each 18-350 4647
Globe valves, gunmetal, screwed both ends, complete with Each 18-351 1205
steel handle Class-150, 15 mm dia, supply and fixing.

Same as item 18-351, but 20 mm dia. Each 18-352 1488


Same as item 18-351, but 25 mm dia. Each 18-353 2215
Same as item 18-351, but 40 mm dia. Each 18-354 3311
Same as item 18-351, but 50 mm dia. Each 18-355 5185
Same as item 18-351, but 65 mm dia. Each 18-356 7887
Globe valves, gunmetal, flanged and drilled to BS Table 18-1- Each 18-357 11397
10, complete with steel handle Class-150, 80mm dia, supply
and fixing.
Same as item 18-357, but 100mm dia, with CI body. Each 18-358 16021
Same as item 18-357, but 150mm dia, with CI body. Each 18-359 25856
Sluice Valves
Sluice Valve, according to BSS-3464 class 150,(Table 18-1-6) Each 18-360 11397
flanged and drilled to BS, Table 18-1-10, complete with
rubber packing, 80 mm dia, supply and fixing.
Same as item 18-360, but 100 mm dia Each 18-361 14221
Same as item 18-360, but 150 mm dia Each 18-362 23012
Same as item 18-360, but 200 mm dia. Each 18-363 36305
Same as item 18-360, but 250 mm dia. Each 18-364 66885
Same as item 18-360, but 300 mm dia. Each 18-365 101092
Sluice Valve, according to BSS-5150/5163, PN-16, (Table 18-1- Each 18-366 11637
8) flanged and drilled to BS Table 18-1-10, complete with
rubber packing, 80 mm dia, supply and fixing.

Same as item 18-366, but 100 mm dia. Each 18-367 19261


Same as item 18-366, but 150 mm dia. Each 18-368 24056
Same as item 18-366, but 200 mm dia. Each 18-369 38465
Same as item 18-366, but 250 mm dia. Each 18-370 70485
Same as item 18-366, but 300 mm dia. Each 18-371 108232
Non Return Valves
Non return valve or reflux valve, screwed, 15 mm dia, supply Each 18-372 1060
and fixing.
Same as item 18-372 but 20 mm dia. Each 18-373 1304
Same as item 18-372, but 25 mm dia. Each 18-374 1855
Same as item 18-372, but 40 mm dia. Each 18-375 2711
Same as item 18-372, but 50 mm dia. Each 18-376 5845
Same as item 18-372, but 65 mm dia. Each 18-377 7287
Same as item 18-372, flanged and drilled to BS Table 18-1-10, Each 18-378 11877
80 mm dia.
Same as item 18-378, but 100 mm dia. Each 18-379 15901
Same as item 18-378, but 150 mm dia. Each 18-380 21656
Same as item 18-378, but 200 mm dia. Each 18-381 34489
Same as item 18-345, 18-351, 18-372, but fixing only. Each 18-382 37
Same as item 18-346, 18-352, or18-373, but fixing only. Each 18-383 48

Same as item 18-347, 18-353, or 18-374, but fixing only. Each 18-384 55

Same as item 18-348, 18-354, or18-375, but fixing only. Each 18-385 71

Same as item 18-349, 18-355, or 18-376, but fixing only. Each 18-386 85

Same as item 18-350, 18-356 or 18-377 but fixing only. Each 18-387 87

Same as item 18-357, 18-360, 18-366, or 18-378 but fixing Each 18-388 357
only.
Same as item 18-358, 18-361, 18-367or 18-379 but fixing Each 18-389 421
only.
Same as item 18-359, 18-362, 18-368 or 18-380, but fixing Each 18-390 656
only.
Same as item 18-363, 18-369, or 18-381, but fixing only. Each 18-391 785

Same as item 18-364 or 18-370, but fixing only. Each 18-392 885
Same as item 18-365 or, 18-371, but fixing only. Each 18-393 1432
Add to item 18-345, 18-351, 18-372 or 18-382, if removal Each 18-394 26
only.
Add to item 18-346, 18-352, 18-373, or 18-383 if removal Each 18-395 31
only.
Add to item 18-347, 18-353, 18-374, or 18-384 if removal Each 18-396 36
only.
Add to item 18-348, 18-354, 18-375, or 18-385, if removal Each 18-397 47
only.
Add to item 18-349, 18-355, 18-376, or 18-386 if removal Each 18-398 57
only.
Add to item 18-350, 18-356, 18-377, or 18-387 if removal Each 18-399 57
only.
Add to item 18-357, 18-360, 18-366, 18-378 or 18-388, if Each 18-400 129
removal only.
Add to item 18-358, 18-361, 18-367, 18-379 or 18-389, if Each 18-401 195
removal only.
Add to item 18-359, 18-362, 18-368, 18-380 or 18-390, if Each 18-402 307
removal only.
Add to item 18-363, 18-369, 18-381 or 18-391, if removal Each 18-403 369
only.
Add to item 18-364 or 18-370 or 18-392, if removal only. Each 18-404 395

Add to item 18-365, 18-371 or 18-393, if removal only Each 18-405 661

Ball / Float Valves


Ball valves, brass (Corydon) or other approved pattern, with Each 18-406 727
plastic ball screwed for iron (brass ferrule), 15mm dia supply
and fixing.
Same as item 18-406, but 20mm dia. Each 18-407 1234
Same as item 18-406, but 25mm dia. Each 18-408 1673
Same as item 18-406, with copper ball, but 40mm dia. Each 18-409 3857
Same as item 18-406, but 50 mm dia. Each 18-410 5485
Foot Valve
Foot valve complete with strainer screwed 25mm dia, supply Each 18-411 783
and fixing.
Same as item 18-411, but 40 mm dia. Each 18-412 2052
Same as item 18-411, but 50 mm dia. Each 18-413 2727
Same as item 18-411, but 65 mm dia. Each 18-414 4143
Same as item 18-411, but flanged and drilled to BS Table 18-1- Each 18-415 5179
10, 80 mm dia.
Same as item 18-415, but 100 mm dia Each 18-416 7474
Same as item 18-415, but 150 mm dia Each 18-417 11333
Same as item 18-415, but 200 mm dia Each 18-418 18038
Same as item 18-406 to 18-408 or 18-411, but fixing only. Each 18-419 57

Same as item 18-409 or 18-412, but fixing only. Each 18-420 72


Same as item 18-410 or 18-413, but fixing only. Each 18-421 87
Same as item 18-414, but fixing only. Each 18-422 183
Same as item 18-415, but fixing only. Each 18-423 295
Same as item 18-416, but fixing only. Each 18-424 341
Same as item 18-417, but fixing only. Each 18-425 533
Same as item 18-418, but fixing only. Each 18-426 437
Add to item 18-406 to 18-408, 18-411 or 18-419, if removal Each 18-427 36
only.
Add to item 18-409, 18-412 or 18-420, if removal only. Each 18-428 47

Add to item 18-410, 18-413 or 18-421, if removal only. Each 18-429 57

Add to item 18-414 or 18-422, if removal only. Each 18-430 129


Add to item 18-415 or 18-423, if removal only. Each 18-431 174
Add to item 18-416 or 18-424, if removal only. Each 18-432 195
Add to item 18-417 or 18-425, if removal only. Each 18-433 307
Add to item 18-418 or 18-426, if removal only. Each 18-434 369
Air Valves
Air valve automatic, 50 mm size, single acting, supply and Each 18-435 6085
fixing.
Same as item 18-435, but double acting. Each 18-436 17965
Same as item 18-435 or 18-436, but fixing only. Each 18-437 85
Add to item 18-435, 18-436 or 18-437, if removal only. Each 18-438 57

Fire Hydrant
Fire Hydrant flanged and drilled to BS Table 18-1-10, Each 18-439 19670
complete with rubber packing, 65 mm dia, supply and fixing.

Same as 18-439, but 80 mm dia. Each 18-440 22670


Same as item 18-439 or 18-440, but fixing only. Each 18-441 470
Add to item 18-439, 18-440 or 18-441, if removal only. Each 18-442 259

Flange – MS / GI Screwed
Flanges MS/GI, drilled to B.S Table 18-1-10, for screwed pipe, Each 18-443 443
25 mm dia, supply and fixing.
Same as item 18-443, but 40mm dia. Each 18-444 515
Same as item 18-443, but 50mm dia. Each 18-445 522
Same as item 18-443, but 65mm dia. Each 18-446 709
Same as item 18-443, but 80mm dia. Each 18-447 797
Same as item 18-443, but 100mm dia. Each 18-448 1470
Same as item 18-443, but 150mm dia. Each 18-449 2113
Same as item 18-443, but 200mm dia. Each 18-450 4110
Same as item 18-443, but 250mm dia. Each 18-451 5887
Same as item 18-443, but 300mm dia. Each 18-452 7307
Same as item 18-443, but fixing only. Each 18-453 83
Same as item 18-444, but fixing only. Each 18-454 95
Same as item 18-445, but fixing only. Each 18-455 102
Same as item 18-446, but fixing only. Each 18-456 166
Same as item 18-447, but fixing only. Each 18-457 197
Same as item 18-448, but fixing only. Each 18-458 211
Same as item 18-449, but fixing only. Each 18-459 313
Same as item 18-450, but fixing only. Each 18-460 429
Same as item 18-451, but fixing only. Each 18-461 487
Same as item 18-452, but fixing only. Each 18-462 689
Add to item 18-443 or 18-453, if removal only. Each 18-463 18
Add to item 18-444 or 18-454, if removal only. Each 18-464 23
Add to item 18-445 or 18-455, if removal only. Each 18-465 28
Add to item 18-446 or 18-456, if removal only. Each 18-466 52
Add to item 18-447 or 18-457, if removal only. Each 18-467 65
Add to item 18-448 or 18-458, if removal only. Each 18-468 98
Add to item 18-449 or 18-459 if removal only. Each 18-469 122
Add to item 18-450 or 18-460, if removal only. Each 18-470 184
Add to item 18-451 or 18-461, if removal only. Each 18-471 197
Add to item 18-452 or 18-462, if removal only. Each 18-472 276
Flange – MS / GI Welded
Flanges MS/GI, drilled to B.S, Table 18-1-10, for Welded pipe, Each 18-473 388
25mm dia, supply and fixing.
Same as item 18-473, but 40mm dia. Each 18-474 585
Same as item 18-473, but 50mm dia. Each 18-475 683
Same as item 18-473, but 65mm dia. Each 18-476 791
Same as item 18-473, but 80mm dia. Each 18-477 902
Same as item 18-473, but 100mm dia. Each 18-478 1397
Same as item 18-473, but 150mm dia. Each 18-479 2142
Same as item 18-473, but 200mm dia. Each 18-480 3089
Same as item 18-473, but 250mm dia. Each 18-481 4335
Same as item 18-473, but 300mm dia. Each 18-482 5702
Same as item 18-473, but fixing only. Each 18-483 150
Same as item 18-474, but fixing only. Each 18-484 225
Same as item 18-475, but fixing only. Each 18-485 299
Same as item 18-476, but fixing only. Each 18-486 370
Same as item 18-477, but fixing only. Each 18-487 445
Same as item 18-478, but fixing only. Each 18-488 592
Same as item 18-479, but fixing only. Each 18-489 881
Same as item 18-480, but fixing only. Each 18-490 1168
Same as item 18-481, but fixing only. Each 18-491 1455
Same as item 18-482, but fixing only. Each 18-492 1743
Add to item 18-473 or 18-483, if removal only. Each 18-493 6
Add to item 18-474 or 18-484, if removal only. Each 18-494 10
Add to item 18-475 or 18-485, if removal only. Each 18-495 14
Add to item 18-476 or 18-486, if removal only. Each 18-496 13
Add to item 18-477 or 18-487, if removal only. Each 18-497 17
Add to item 18-478 or 18-488, if removal only. Each 18-498 20
Add to item 18-479 or 18-489 if removal only. Each 18-499 23
Add to item 18-480 or 18-490, if removal only. Each 18-500 23
Add to item 18-481 or 18-491, if removal only. Each 18-501 23
Add to item 18-482 or 18-492, if removal only. Each 18-502 23
Brass Spindles
Brass Spindle with nuts, for 80 mm dia, Gate valves, supply Each 18-503 2246
and fixing.
Same as item 18-503, but 100 mm dia. Each 18-504 3086
Same as item 18-503, but 150 mm dia. Each 18-505 4646
Same as item 18-503, but 200 mm dia. Each 18-506 5573
Same as item 18-503, but 250 mm dia. Each 18-507 6533
Same as item 18-503, but 300 mm dia. Each 18-508 11573
Same to item 18-503 to 18-505, but fixing only. Each 18-509 86
Same as item 18-506 to 18-508, but fixing only. Each 18-510 173
Add to item 18-503 to 18-505 or 18-509 if removal only. Each 18-511 65

Add to item 18-506 to 18-508 or 18-510 if removal only. Each 18-512 129

Water Tanks – Polyethylene (PE)


Water tank Polyethylene (PE) vertical, 50 gallons capacity, Each 18-513 3465
supply and fixing.
Same as item 18-513 but, 150 gallons capacity. Each 18-514 5865
Same as item 18-513 but, 200 gallons capacity. Each 18-515 6825
Same as item 18-513 but, 250 gallons capacity. Each 18-516 7665
Same as item 18-513 but, 300 gallons capacity. Each 18-517 9518
Same as item 18-513 but, 400 gallons capacity. Each 18-518 11678
Same as item 18-513 but, 500 gallons capacity. Each 18-519 14078
Same as item 18-513 but, 1000 gallons capacity. Each 18-520 55720
Water tank Polyethylene (PE) horizontal, 150 gallons Each 18-521 5865
capacity, supply and fixing.
Same as item 18-521 but, 200 gallons capacity. Each 18-522 6825
Same as item 18-521 but, 250 gallons capacity. Each 18-523 7665
Same as item 18-521 but, 300 gallons capacity. Each 18-524 9518
Same as 18-513 to 18-516 or 18-521 to 18-523, but fixing Each 18-525 465
only.
Same as 18-517 to 18-519 or 18-524, but fixing only. Each 18-526 878
Same as 18-520, but fixing only. Each 18-527 2115
Add to item 18-513 to 18-516, 18-521 to 18-523 or 18-525, if Each 18-528 349
removal only.
Add to item 18-517 to 18-519, 18-524 or 18-526 if removal Each 18-529 658
only.
Add to item 18-520 or 18-527, if removal only. Each 18-530 1586
Water Coolers
Electric Water Cooler, SP, 220/240V, cooling capacity 30 to Each 18-531 38385
40 Lit/hr, complete, supply and fixing.
Same as item 18-531, but 60 Lit/hr, capacity. Each 18-532 43785
Same as item 18-531, but 80 Lit/hr capacity. Each 18-533 51998
Same as item 18-531, but 100 Lit/hr capacity. Each 18-534 62198
Same as item 18-531, but 200 Lit/hr capacity. Each 18-535 152250
Same as item 18-531 to 18-532, but fixing only. Each 18-536 345
Same as item 18-533 to 18-534, but fixing only. Each 18-537 518
Same as item 18-535 but fixing only. Each 18-538 690
Add to item 18-531 to 18-532 or 18-536, if removal only. Each 18-539 259

Add to item 18-533 to 18-534 or 18-537, if removal only. Each 18-540 388

Add to item 18-535 or 18-538, if removal only. Each 18-541 518


Water Filters
Water filter, 3 stage, consisting of polypropylene fiber Each 18-542 9906
cartridge 5 micron, granular activated carbon cartridge 1
micron, and size of cartridge 10" with ultra violet lamp, water
flow rate 2 GPM complete, supply and fixing.

Same as item 18-542, but 3 GPM. Each 18-543 16362


Same as item 18-542, but 8 GPM. Each 18-544 17086
Same as item 18-542 to 18-544, but fixing only. Each 18-545 162
Add to item 18-542 to 18-545, if removal only. Each 18-546 122
PE – Pipes
Polyethylene Pipe (PE-100), 20 mm dia, Class PN-10 / SDR-17 Metre 18-547 140
(excluding cost of excavation), supply and fixing.

Same as item 18-547, but 25 mm dia. Metre 18-548 146


Same as item 18-547, but 32 mm dia. Metre 18-549 172
Same as item 18-547, but 40 mm dia. Metre 18-550 249
Same as item 18-547, but 50 mm dia. Metre 18-551 321
Same as item 18-547, but 63 mm dia. Metre 18-552 440
Same as item 18-547, but 75 mm dia. Metre 18-553 623
Same as item 18-547, but 90 mm dia. Metre 18-554 821
Same as item 18-547, but 110 mm dia, complete with fusion Metre 18-555 1090
joint.
Same as item 18-555, but 125 mm dia Metre 18-556 1356
Same as item 18-555, but 160 mm dia Metre 18-557 2151
Same as item 18-555, but 180 mm dia Metre 18-558 2710
Same as item 18-555, but 200 mm dia Metre 18-559 3316
Same as item 18-555, but 250 mm dia Metre 18-560 5115
Same as item 18-555, but 280 mm dia Metre 18-561 6950
Same as item 18-555, but 315 mm dia Metre 18-562 8850
Same as item 18-555, but 355 mm dia Metre 18-563 11212
Same as item 18-555, but 400 mm dia Metre 18-564 14013
Same as item 18-555, but 450 mm dia Metre 18-565 17533
Polyethylene Pipe (PE-100), 20 mm dia, Class PN-12.5/SDR- Metre 18-566 133
13.6 (excl cost of excavation), supply and fixing.

Same as item 18-566, but 25 mm dia. Metre 18-567 152


Same as item 18-566, but 32 mm dia. Metre 18-568 188
Same as item 18-566, but 40 mm dia. Metre 18-569 280
Same as item 18-566, but 50 mm dia. Metre 18-570 367
Same as item 18-566, but 63 mm dia. Metre 18-571 515
Same as item 18-566, but 75 mm dia. Metre 18-572 732
Same as item 18-566, but 90 mm dia. Metre 18-573 976
Same as item 18-566, but 110 mm dia, complete with fusion Metre 18-574 1608
joint.
Same as item 18-574, but 125 mm dia Metre 18-575 1953
Same as item 18-574, but 160 mm dia Metre 18-576 2797
Same as item 18-574, but 180 mm dia Metre 18-577 3648
Same as item 18-574, but 200 mm dia Metre 18-578 4377
Same as item 18-574, but 250 mm dia Metre 18-579 6764
Same as item 18-574, but 280 mm dia Metre 18-580 10138
Same as item 18-574, but 315 mm dia Metre 18-581 10921
Same as item 18-574, but 355 mm dia Metre 18-582 13810
Same as item 18-574, but 400 mm dia Metre 18-583 17345
Same as item 18-574, but 450 mm dia Metre 18-584 21744
Polyethylene Pipe (PE-100), 20 mm dia Class PN-16 / SDR-11 Metre 18-585 138
(excluding cost of excavation), supply and fixing.
Same as item 18-585, but 25 mm dia. Metre 18-586 161
Same as item 18-585, but 32 mm dia. Metre 18-587 212
Same as item 18-585, but 40 mm dia. Metre 18-588 314
Same as item 18-585, but 50 mm dia. Metre 18-589 421
Same as item 18-585, but 63 mm dia. Metre 18-590 598
Same as item 18-585, but 75 mm dia. Metre 18-591 840
Same as item 18-585, but 90 mm dia. Metre 18-592 1860
Same as item 18-585, but 110 mm dia complete with fusion Metre 18-593 2195
joint.
Same as item 18-593, but 125 mm dia. Metre 18-594 2284
Same as item 18-593, but 160 mm dia. Metre 18-595 3336
Same as item 18-593, but 180 mm dia. Metre 18-596 4319
Same as item 18-593, but 200 mm dia. Metre 18-597 5219
Same as item 18-593, but 250 mm dia. Metre 18-598 8057
Same as item 18-593, but 280 mm dia. Metre 18-599 10420
Same as item 18-593, but 315 mm dia. Metre 18-600 13074
Same as item 18-593, but 355 mm dia. Metre 18-601 16551
Same as item 18-593, but 400 mm dia. Metre 18-602 20840
Same as item 18-593, but 450 mm dia. Metre 18-603 26187
Same as item 18-547 to 18-549,18-566 to 18-568, 18-585 to Metre 18-604 86
18-587 but fixing only.
Same as item 18-550 to 18-552, 18-569 to 18-571, 18-588 to Metre 18-605 121
18-590 but fixing only.
Same as item 18-553 to 18-554, 18-572 to18-573, 18-591 to Metre 18-606 173
18-592but fixing only.
Same as item 18-555 to 18-557, 18-574 to18-576, 18-593 to Metre 18-607 421
18-595 but fixing only.
Same as item 18-558 to 18-559, 18-577 to 18-578, 18-596 to Metre 18-608 458
18-597 but fixing only.
Same as item 18-560 to 18-562, 18-579 to 18-581, 18-598 to Metre 18-609 632
18-600 but fixing only.
Same as item 18-563 to 18-565, 18-582 to 18-584, 18-601 to Metre 18-610 839
18-603 but fixing only.
Add to item 18-547 to 18-549,18-566 to 18-568, 18-585 to Metre 18-611 65
18-587 or 18-604 if removal only.
Add to item 18-550 to 18-552, 18-569 to 18-571, 18-588 to Metre 18-612 91
18-590 or 18-605 if removal only.
Add to item 18-553 to 18-554, 18-572 to18-573, 18-591 to Metre 18-613 129
18-592 or 18-606 if removal only.
Add to item 18-555 to 18-557, 18-574 to18-576, 18-593 to Metre 18-614 91
18-595 or 18-607 if removal only.
Add to item 18-558 to 18-559, 18-577 to 18-578, 18-596 to Metre 18-615 104
18-597 or 18-608 if removal only.
Add to item 18-560 to 18-562, 18-579 to 18-581, 18-598 to Metre 18-616 129
18-600 or 18-609 if removal only.
Add to item 18-563 to 18-565, 18-582 to 18-584, 18-601 to Metre 18-617 173
18-603 or 18-610 if removal only.
Butt fusion joint 110 mm to 160 mm dia complete. Each 18-618 1800
Same as item 18-618 but 180 mm to 200 mm dia Each 18-619 1920
Same as item 18-618 but 225 mm to 315 mm dia Each 18-620 2760
Same as item 18-618 but 355 mm to 450 mm dia Each 18-621 3600
Coupler / Socket
Coupler/Socket, 20 mm dia, for PE pipe supply and fixing. Each 18-622 110

Same as item 18-622, but 25 mm dia. Each 18-623 145


Same as item 18-622, but 32 mm dia. Each 18-624 195
Same as item 18-622, but 40 mm dia. Each 18-625 370
Same as item 18-622, but 50 mm dia. Each 18-626 568
Same as item 18-622, but 63 mm dia. Each 18-627 896
Same as item 18-622, but 75 mm dia. Each 18-628 1218
Same as item 18-622, but 90 mm dia. Each 18-629 2101
Same as item 18-622 but 110 mm dia. Each 18-630 2306
Reducing Coupler / Socket
Reducing Coupler/Socket 25 x 20 mm dia, for PE pipe, supply Each 18-631 156
and fixing.
Same as item 18-631, but 32 x 20 mm dia. Each 18-632 185
Same as item 18-631, but 32 x 25 mm dia. Each 18-633 206
Same as item 18-631, but 40 x 25 mm dia. Each 18-634 323
Same as item 18-631, but 40 x 32 mm dia. Each 18-635 355
Same as item 18-631, but 50 x 25 mm dia. Each 18-636 335
Same as item 18-631, but 50 x 32 mm dia. Each 18-637 469
Same as item 18-631 but 50 x 40 mm dia. Each 18-638 559
Same as item 18-631, but 63 x 32 mm dia. Each 18-639 670
Same as item 18-631, but 63 x 50 mm dia. Each 18-640 872
Same as item 18-631, but 75 x 50 mm dia or 75 x 63 mm Each 18-641 890

Same as item 18-631, but 90 x 63 mm dia or but 90 x 75 mm Each 18-642 908


dia
Same as item 18-631, but 110 x 63 mm or 110 x 90mm dia, Each 18-643 954
110 x 75 mm dia. Butt Fusion fitting.
Same as item 18-643, but 125 x90 mm or 125mm x 110mm Each 18-644 1310
dia.
Same as item 18-643, but 160 x 90 mm dia or 160 x110 mm Each 18-645 1707
dia
Same as item 18-643, but 160 x 125 mm or 180 x 90 mm dia. Each 18-646 2060

Same as item 18-643, but 180 x 110mm, 180 x 125 mm or Each 18-647 3163
180 x 160 mm dia.
Same as item 18-643, but 200 x 160 mm or 200 x 180 mm Each 18-648 3843
dia.
Same as item 18-643 but 200 x 90 mm dia, Each 18-649 3843
Same as item 18-643, but 200 x 110 mm dia. Each 18-650 4188
Same as item 18-643, but 200 x 160 mm dia. Each 18-651 4188
Same as item 18-643 but 250 x 90 mm dia, Each 18-652 8416
Same as item 18-643 but 250 x 110 mm dia, Each 18-653 8416
Same as item 18-643 but 250 x 160 mm dia, Each 18-654 7577
Same as item 18-643, but 250 x 180 mm dia. Each 18-655 7914
Same as item 18-643 but 250 x 200 mm dia, Each 18-656 7927
Same as item 18-643 but 280 x 110 mm dia, Each 18-657 10175
Same as item 18-643 but 280 x 160 mm dia, Each 18-658 10175
Same as item 18-643 but 280 x 200 mm dia, Each 18-659 11523
Same as item 18-643 but 315 x 90 mm dia, Each 18-660 12050
Same as item 18-643 but 315 x 110 mm dia, Each 18-661 12188
Same as item 18-643 but 315 x 160 mm dia, Each 18-662 12435
Same as item 18-643 but 315 x 250 mm dia, Each 18-663 12615
Same as item 18-643 but 355 x 160 mm dia, Each 18-664 13147
Same as item 18-643 but 400 x 315 mm dia. Each 18-665 15914
Same as item 18-643 but 450 x 200 mm dia, Each 18-666 28591
Same as item 18-618 to 18-620, 18-627 to 18-629, but fixing Each 18-667 35
only.
Same as item 18-621 to 18-623, 18-630 to 18-635 but fixing Each 18-668 69
only.
Same as item 18-624 to 18-626, 18-636 to 18-640, but fixing Each 18-669 86
only.
Same as item 18-641 to 18-646, but fixing only. Each 18-670 121
Same as item 18-647 to 18-651 but fixing only. Each 18-671 342
Same as item 18-652 to 18-663, but fixing only. Each 18-672 342
Same as item 18-664 to 18-666, but fixing only. Each 18-673 442
Add to item 18-618 to 18-620, 18-627 to 18-629 or 18-667 if Each 18-674 26
removal only.
Add to item 18-621 to 18-623, 18-630 to 18-635 or 18-668 if Each 18-675 52
removal only.
Add to item 18-624 to 18-626, 18-636 to 18-640 or 18-669, if Each 18-676 65
removal only.
Add to item 18-641 to 18-646 or 18-670, if removal only. Each 18-677 91

Add to item 18-647 to 18-651 or 18-671, if removal only. Each 18-678 138

Add to item 18-652 to 18-663 or 18-672, if removal only. Each 18-679 173

Add to item 18-664 to 18-666 or 18-673, if removal only. Each 18-680 206

Tee Equal
Tee Equal, 20 mm dia, for PE pipe, supply and fixing. Each 18-681 175
Same as item 18-681, but 25 mm dia. Each 18-682 271
Same as item 18-681, but 32 mm dia. Each 18-683 354
Same as item 18-681, but 40 mm dia. Each 18-684 624
Same as item 18-681, but 50 mm dia. Each 18-685 686
Same as item 18-681, but 63 mm dia. Each 18-686 830
Same as item 18-681, but 75 mm dia. Each 18-687 960
Same as item 18-681, but 90 mm dia. Each 18-688 1256
Same as item 18-681, but 110 mm dia, with Butt Fusion Each 18-689 1599
fitting.
Same as item 18-689, but 125 mm dia. Each 18-690 2886
Same as item 18-689, but 160 mm dia. Each 18-691 3504
Same as item 18-689, but 180 mm dia. Each 18-692 6439
Same as item 18-689, but 200 mm dia Each 18-693 6518
Same as item 18-689, but 250 mm dia. Each 18-694 14292
Same as item 18-689, but 280 mm dia. Each 18-695 27023
Same as Item 18-689, but 315 mm dia. Each 18-696 28525
Same as Item 18-689, but 355 mm dia. Each 18-697 34432
Same as Item 18-689, but 400 mm dia. Each 18-698 48709
Same as Item 18-689, but 450 mm dia. Each 18-699 79646
Reducing Tee
Reducing Tee 25 x 20 mm dia for PE pipe, supply and fixing. Each 18-700 297

Same as item 18-700, but 32 x 20 mm dia. Each 18-701 316


Same as item 18-700, but 32 x 25 mm dia. Each 18-702 324
Same as item 18-700, but 40 x 32 mm dia. Each 18-703 526
Same as item 18-700, but 50 x 25 mm dia. Each 18-704 849
Same as item 18-700, but 50 x 32 mm dia. Each 18-705 907
Same as item 18-700, but 50 x 40 mm dia. Each 18-706 977
Same as item 18-700, but 63 x 32 mm dia. Each 18-707 1398
Same as item 18-700, but 63 x 50 mm dia. Each 18-708 1486
Same as item 18-700, but 75 x 63 mm dia. Each 18-709 1723
Same as item 18-700, but 90 x 63 mm dia. Each 18-710 1891
Same as item 18-700, but 90 x 75 mm dia. Each 18-711 2083
Same as item 18-700 but 125 x 90 mm dia, with Butt Fusion Each 18-712 2552
fitting.
Same as item 18-712, but 160 x 90 mm dia. Each 18-713 3027
Same as item 18-712, but 160 x110 mm dia. Each 18-714 3027
Same as item 18-712, but 180 x 125 mm dia. Each 18-715 5329
Same as item 18-712, but 200 x 90 mm dia. Each 18-716 8162
Same as item 18-712, but 200 x 110 mm dia. Each 18-717 8372
Same as item 18-712, but 200 x 160 mm dia. Each 18-718 8558
Same as item 18-712, but 250 x 90 mm dia. Each 18-719 12968
Same as item 18-712, but 250 x 110 mm dia. Each 18-720 12968
Same as item 18-712, but 250 x 160 mm dia. Each 18-721 14556
Same as item 18-712, but 250 x 200 mm dia. Each 18-722 14556
Same as item 18-712, but 280 x 110 mm dia. Each 18-723 15761
Same as item 18-712, but 280 x 250 mm dia. Each 18-724 18569
Same as item 18-712, but 315 x 90 mm dia. Each 18-725 19314
Same as item 18-712, but 315 x 110 mm dia. Each 18-726 19314
Same as item 18-712, but 315 x 160 mm dia. Each 18-727 21298
Same as item 18-712, but 315 x 250 mm dia. Each 18-728 21298
Same as item 18-712, but 355 x 160 mm dia. Each 18-729 25660
Same as item 18-712, but 355 x 250 mm dia. Each 18-730 32845
Same as item 18-712, but 400 x 110 mm dia. Each 18-731 32845
Same as item 18-712, but 400 x 315 mm dia. Each 18-732 47917
Same as item 18-712, but 450 x 160 mm dia. Each 18-733 47917
Same as item 18-712, but 450 x 250 mm dia. Each 18-734 63781
Same as item 18-681 to 18-683, 18-700 to 18-703,but fixing Each 18-735 52
only.
Same as item 18-684 to 18-686 or 18-704 to 18-707, but Each 18-736 86
fixing only.
Same as item 18-687 to 18-688 or 18-708 to 18-711, but Each 18-737 104
fixing only.
Same as item 18-689 to 18-691 or 18-712 to 18-714, but Each 18-738 173
fixing only.
Same as item 18-692 to 18-693 or 18-715 to 18-718, but Each 18-739 690
fixing only.
Same as item 18-694 to 18-695 or 18-719 to 18-728, but Each 18-740 690
fixing only.
Same as item 18-696 to 18-699 or 18-729 to 18-734, but Each 18-741 690
fixing only.
Add to item 18-681 to 18-683, 18-700 to 18-703, or 18-735 if Each 18-742 39
removal only.
Add to item 18-684 to 18-686, 18-704 to 18-707 or 18-736 if Each 18-743 65
removal only.
Add to item 18-687 to 18-688, 18-708 to 18-711 or 18-737 if Each 18-744 78
removal only.
Add to item 18-689 to 18-691, 18-712 to 18-714 or 18-738 if Each 18-745 129
removal only.
Add to item 18-692 to 18-693, 18-715 to 18-718 or 18-739 if Each 18-746 345
removal only.
Add to item 18-694 to 18-695, 18-719 to 18-728 or 18-740 if Each 18-747 345
removal only.
Add to item 18-696 to 18-699, 18-729 to 18-734 or 18-741 if Each 18-748 345
removal only.
Male / Female Tee
Male /Female Tee 20 mm x 15mm dia, for PE pipe, Supply Each 18-749 196
and Fixing.
Same as item 18-749, but 20 x 20 mm dia. Each 18-750 217
Same as item 18-749, but 25 x 25 mm dia. Each 18-751 288
Same as item 18-749, but 25 x 20 mm dia. Each 18-752 281
Same as item 18-749, but 32 x 25 mm dia Each 18-753 421
Same as item 18-749, but 32 x 20 mm dia Each 18-754 329
Same as item 18-749, but 50 x 32 mm dia. Each 18-755 802
Same as item 18-749, but 50 x 40 mm dia. Each 18-756 1025
Same as item 18-749, but 63 x 50 mm dia. Each 18-757 1415
Same as item 18-749, but 90 x 75 mm dia. Each 18-758 2792
Same as item 18-749 to 18-752, but fixing only. Each 18-759 52
Same as item 18-753 to 18-756, but fixing only. Each 18-760 86
Same as item 18-757 to 18-758, but fixing only. Each 18-761 104
Add to item 18-749 to 18-752 or 18-759, if removal only. Each 18-762 39

Add to item 18-753 to 18-756 or 18-760, if removal only. Each 18-763 65

Add to item 18-757 to 18-758 or 18-761, if removal only. Each 18-764 78

Bend
Bend 20 mm dia for PE pipe, supply and fixing. Each 18-765 121
Same as item 18-765, but 25 mm dia. Each 18-766 171
Same as item 18-765, but 32 mm dia. Each 18-767 225
Same as item 18-765, but 40 mm dia. Each 18-768 430
Same as item 18-765, but 50 mm dia. Each 18-769 663
Same as item 18-765, but 63 mm dia. Each 18-770 1047
Same as item 18-765, but 75 mm dia. Each 18-771 1641
Same as item 18-765, but 90 mm dia. Each 18-772 1982
Elbow
Elbow, 110 mm dia, for PE pipe, with Butt Fusion joint, supply Each 18-773 1196
and fixing.
Same as item 18-773, but 125 mm dia. Each 18-774 2588
Same as item 18-773, but 160 mm dia. Each 18-775 2738
Same as item 18-773, but 180 mm dia. Each 18-776 4483
Same as item 18-773, but 200 mm dia. Each 18-777 5038
Same as item 18-773, but 250 mm dia. Each 18-778 8449
Same as item 18-773, but 280 mm dia Each 18-779 18673
Same as Item18-773, but 315 mm dia Each 18-780 20267
Same as Item18-773, but 355 mm dia Each 18-781 26501
Same as Item18-773, but 400 mm dia Each 18-782 34432
Same as Item18-773, but 450 mm dia Each 18-783 47124
Male / Female Bend
Male / Female Bend, 20 x 15 mm dia, for PE pipe, supply and Each 18-784 93
fixing
Same as item 18-784, but 20 x 20 mm dia Each 18-785 133
Same as item 18-784, but 25 x 25 mm dia Each 18-786 129
Same as item 18-784, but 25 x 20 mm dia Each 18-787 196
Same as item 18-784, but 25 x 15 mm dia Each 18-788 129
Same as item 18-784, but 32 x 20 mm dia Each 18-789 193
Same as item 18-784, but 32 x 25 mm dia Each 18-790 249
Same as item 18-784, but 40 x 32 mm dia Each 18-791 434
Same as item 18-784, but 50 x 32 mm dia Each 18-792 499
Same as item 18-784, but 50 x 40 mm dia Each 18-793 536
Same as item 18-784, but 63 x 50 mm dia Each 18-794 722
Same as item 18-784, but 90 x 75 mm dia Each 18-795 2069
Same as item 18-765 to 18-767, 18-784 to 18-787, but fixing Each 18-796 35
only.
Same as item 18-768 to 18-770, 18-788 to 18-791, but fixing Each 18-797 69
only.
Same as item 18-771 to 18-772, 18-792 to 18-795, but fixing Each 18-798 86
only.
Same as item 18-773 to 18-775, but fixing only. Each 18-799 121
Same as item 18-776 to 18-777, but fixing only. Each 18-800 121
Same as item 18-778 to 18-780, but fixing only. Each 18-801 121
Same as item 18-781 to 18-783, but fixing only. Each 18-802 690
Add to item 18-765 to 18-767, 18-784 to 18-787 or 18-796 if Each 18-803 26
removal only.
Add to item 18-768 to 18-770, 18-788 to 18-791, or 18-797 if Each 18-804 52
removal only.
Add to item 18-771 to 18-772, 18-792 to 18-795, or 18-798 if Each 18-805 65
removal only.
Add to item 18-773 to 18-775, or 18-799 if removal only. Each 18-806 91

Add to item 18-776 to 18-777, or 18-800 if removal only. Each 18-807 93

Add to item 18-778 to 18-780, or 18-801 if removal only. Each 18-808 93

Add to item 18-781 to 18-783, or 18-802 if removal only. Each 18-809 518

Male Threaded Adapter


Male Threaded Adapter, 20 x 15 mm dia, for PE pipe, supply Each 18-810 106
and fixing.
Same as item 18-810, but 20 x 20 mm dia. Each 18-811 109
Same as item 18-810, but 25 x 25 mm dia Each 18-812 141
Same as item 18-810, but 25 x 20 mm dia. Each 18-813 135
Same as item 18-810, but 25 x 15 mm dia Each 18-814 171
Same as item 18-810, but 32 x 15 mm dia Each 18-815 198
Same as item 18-810, but 32 x 20 mm dia Each 18-816 201
Same as item 18-810, but 32 x 25 mm dia Each 18-817 204
Same as item 18-810, but 40 x 25 mm dia Each 18-818 273
Same as item 18-810, but 40 x 32 mm dia Each 18-819 288
Same as item 18-810, but 40 x 40 mm dia Each 18-820 291
Same as item 18-810, but 50 x 32 mm dia Each 18-821 425
Same as item 18-810, but 50 x 40 mm dia Each 18-822 428
Same as item 18-810, but 63 x 50 mm dia. Each 18-823 641
Same as item 18-810, but 75 x 63 mm dia. Each 18-824 905
Same as item 18-810, but 90 x 75 mm dia. Each 18-825 1306
Same as item 18-810, but 110 x100 mm dia. Each 18-826 2266
Female Threaded Adapter
Female Threaded Adapter, 20 x 15 mm dia, for PE pipe, Each 18-827 145
supply and fixing.
Same as item 18-827, but 20 x 20 mm dia. Each 18-828 149
Same as item 18-827, but 25 x 25 mm dia Each 18-829 172
Same as item 18-827, but 25 x 20 mm dia Each 18-830 169
Same as item 18-827, but 25 x 15 mm dia Each 18-831 200
Same as item 18-827, but 32 x 20 mm dia Each 18-832 236
Same as item 18-827, but 32 x 25 mm dia Each 18-833 242
Same as item 18-827, but 40 x 25 mm dia Each 18-834 348
Same as item 18-827, but 40 x 32 mm dia Each 18-835 91
Same as item 18-827, but 50 x 32 mm dia Each 18-836 416
Same as item 18-827, but 50 x 40 mm dia Each 18-837 530
Same as item 18-827, but 63 x 50 mm dia Each 18-838 765
Same as item 18-827, but 75 x 63 mm dia Each 18-839 1035
Same as item 18-827, but 90 x 75 mm dia Each 18-840 1661
Same as item 18-810 to 18-813, 18-827 to 18-830, but fixing Each 18-841 52
only
Same as item 18-814 to 18-818, 18-831 to 18-834, but fixing Each 18-842 86
only
Same as item 18-819 to 18-826, 18-835 to 18-840, but fixing Each 18-843 104
only
Add to item 18-810 to 18-813, 18-827 to 18-830 or 18-841, if Each 18-844 39
removal only
Add to item 18-814 to 18-818, 18-831 to 18-834 or 18-842 if Each 18-845 65
removal only
Add to item 18-819 to 18-826, 18-835 to 18-840 or 18-843, if Each 18-846 78
removal only
Flange Adapter PE
Flange Adapter stub end with steel ring, rubber packing, Nut Each 18-847 821
bolts etc 50 mm dia for PE Pipe, Supply & Fixing

Same as Item 18-847 but 63 mm dia. Each 18-848 981


Same as Item 18-847 but 75 mm dia. Each 18-849 1084
Same as Item 18-847 but 90 mm dia. Each 18-850 1156
Same as Item 18-847 but 110 mm dia. Each 18-851 1636
Same as Item 18-847 but 125 mm dia. Each 18-852 2131
Same as Item 18-847 but 160 mm dia. Each 18-853 2488
Same as Item 18-847 but 180 mm dia. Each 18-854 3636
Same as Item 18-847 but 200 mm dia. Each 18-855 4338
Same as Item 18-847 but 250 mm dia. Each 18-856 5677
Same as Item 18-847 but 280 mm dia. Each 18-857 7105
Same as Item 18-847 but 315 mm dia. Each 18-858 7535
Same as Item 18-847 but 355 mm dia. Each 18-859 9939
Same as Item 18-847 but 400 mm dia. Each 18-860 13940
Same as Item 18-847 but 450 mm dia. Each 18-861 17907
Same as item 18-847 to 18-850 but fixing only. Each 18-862 584
Same as item 18-851 to 18-853 but fixing only. Each 18-863 1021
Same as item 18-854 to 18-855 but fixing only. Each 18-864 1098
Same as item 18-856 to 18-858 but fixing only. Each 18-865 1553
Same as item 18-859 to 18-861 but fixing only. Each 18-866 2007
Add to item 18-847 to 18-850, or 18-862, if removal only. Each 18-867 78

Add to item 18-851 to 18-853, or 18-863, if removal only. Each 18-868 90


Add to item 18-854 to 18-855, or 18-864, if removal only. Each 18-869 104

Add to item 18-856 to 18-858, or 18-865, if removal only. Each 18-870 129

Add to item 18-859 to 18-861, or 18-866, if removal only. Each 18-871 155

End Cap
End Cap 20 mm dia, for PE pipe, supply and fixing. Each 18-872 92
Same as item 18-872, but 25 mm dia. Each 18-873 113
Same as item 18-872, but 32 mm dia. Each 18-874 139
Same as item 18-872, but 40 mm dia. Each 18-875 229
Same as item 18-872, but 50 mm dia. Each 18-876 370
Same as item 18-872, but 63 mm dia. Each 18-877 473
Same as item 18-872, but 75 mm dia. Each 18-878 494
Same as item 18-872, but 90 mm dia. Each 18-879 524
Same as item 18-872, but 110 mm dia. Each 18-880 545
Same as item 18-872, but 125 mm dia Butt Fusion fitting. Each 18-881 1038

Same as item 18-881, but 160 mm dia. Each 18-882 1196


Same as item 18-881, but 180 mm dia. Each 18-883 1435
Same as item 18-881, but 200 mm dia. Each 18-884 1886
Same as item 18-872 to 18-874, but fixing only. Each 18-885 35
Same as item 18-875 to 18-877, but fixing only. Each 18-886 52
Same as item 18-878 to 18-880, but fixing only. Each 18-887 69
Same as item 18-881 to 18-884, but fixing only. Each 18-888 86
Add to item 18-872 to 18-874 or 18-885, if removal only. Each 18-889 26

Add to item 18-875 to 18-877 or 18-886, if removal only. Each 18-890 39

Add to item 18-878 to 18-880 or 18-887, if removal only. Each 18-891 52

Add to item 18-881 to 18-884 or 18-888, if removal only. Each 18-892 65

PPR (Poly Propylene Random) – Pipes


PPR pipe, with all fittings i.e. socket, bend, tee, elbow, where Metre 18-893 239
required, 20 mm dia, Class PN-20 (excluding excavation),
supply and fixing.
Same as item 18-893, but 25 mm dia. Metre 18-894 259
Same as item 18-893, but 32 mm dia. Metre 18-895 379
Same as item 18-893, but 40 mm dia. Metre 18-896 589
Same as item 18-893, but 50 mm dia. Metre 18-897 946
Same as item 18-893 but 63 mm dia. Metre 18-898 1390
Same as item 18-893, but 75 mm dia. Metre 18-899 2322
Same as item 18-893, but 90 mm dia. Metre 18-900 3351
Same as item 18-893, but 110 mm dia. Metre 18-901 4205
Same as item 18-893 to 18-895, but fixing only. Metre 18-902 86
Same as item 18-896 to 18-898, but fixing only. Metre 18-903 121
Same as item 18-899 to 18-901, but fixing only. Metre 18-904 173
Add to item 18-893 to 18-895 or 18-902, if removal only. Metre 18-905 65

Add to item 18-896 to 18-898 or 18-903, if removal only. Metre 18-906 91

Add to item 18-899 to 18-901 or 18-904, if removal only. Metre 18-907 129

Coupler / Socket
PPR Coupler / Socket, 20 mm dia, supply and fixing. Each 18-908 55
Same as item 18-908, but 25 mm dia. Each 18-909 54
Same as item 18-908, but 32 mm dia. Each 18-910 68
Same as item 18-908, but 40 mm dia. Each 18-911 127
Same as item 18-908, but 50 mm dia. Each 18-912 185
Same as item 18-908, but 63 mm dia. Each 18-913 280
Same as item 18-908, but 75 mm dia. Each 18-914 553
Same as item 18-908, but 90 mm dia. Each 18-915 957
Same as item 18-908, but 110 mm dia Each 18-916 1417
Reducing Coupler / Socket
PPR Reducing Coupler / Socket 25 x 20 mm dia, supply and Each 18-917 65
fixing.
Same as item 18-917, but 32 x 20 mm dia. Each 18-918 73
Same as item 18-917, but 32 x 25 mm dia. Each 18-919 80
Same as item 18-917, but 40 x 20 mm, 40 x 25 mm or 40 x 32 Each 18-920 153
mm dia.
Same as item 18-917, but 50 x 25 mm, 50 x 32 mm or 50 x 40 Each 18-921 154
mm dia.
Same as item 18-917, but 63 x 25 mm dia. Each 18-922 202
Same as item 18-917, but 63 x 35 mm, 63 x 40 mm or 63 x 50 Each 18-923 312
mm dia.
Same as item 18-917, but 75 x 63 mm dia. Each 18-924 1622
Same as item 18-917, but 90 x 63 mm or 90 x 75mm dia. Each 18-925 1622

Same as item 18-917, but 110 x 90 mm dia. Each 18-926 2146


Same as item 18-908 to 18-910, 18-917 to 18-919, but fixing Each 18-927 35
only.
Same as item 18-911 to 18-913, 18-920 to 18-922, but fixing Each 18-928 69
only.
Same as item 18-914 to 18-916, 18-923 to 18-926, but fixing Each 18-929 86
only.
Add to item 18-908 to 18-910, 18-917 to 18-919 or 18-927, if Each 18-930 26
removal only.
Add to item 18-911 to 18-913, 18-920 to 18-922 or 18-928, if Each 18-931 52
removal only.
Add to item 18-914 to 18-916, 18-923 to 18-926 or 18-929, if Each 18-932 65
removal only.
Tee Equal
Tee Equal, 20 mm dia for PPR pipe, supply and fixing. Each 18-933 91
Same as item 18-933, but 25 mm dia. Each 18-934 85
Same as item 18-933, but 32 mm dia. Each 18-935 115
Same as item 18-933, but 40 mm dia. Each 18-936 187
Same as item 18-933, but 50 mm dia. Each 18-937 345
Same as item 18-933, but 63 mm dia. Each 18-938 572
Same as item 18-933, but 75 mm dia. Each 18-939 1222
Same as item 18-933, but 90 mm dia. Each 18-940 2000
Same as item 18-933, but 110 mm dia. Each 18-941 3274
Reducing Tee
Reducing Tee, 25mm x 20mm x 25mm dia for PPR pipe, Each 18-942 83
supply and fixing.
Same as item 18-942, but 32 x 20 x 32mm dia. Each 18-943 123
Same as item 18-942, but 32 x 25 x 32mm dia. Each 18-944 150
Same as item 18-942, but 40 x 20 x 40 mm, 40 x 25 x 40 mm Each 18-945 192
or 40 x 32 x 40 mm dia.
Same as item 18-942, but 50 x 25 x 50 mm, 50 x 32 x 50 mm Each 18-946 455
or 50 x 40 x 50 mm dia.
Same as item 18-942, but 63 x 25 x 63 mm dia. Each 18-947 698
Same as item 18-942, but 63 x 32 x 63 mm dia. Each 18-948 712
Same as item 18-942, but 63 x 40 x 63 mm or 63 x 50 x 63 Each 18-949 741
mm dia.
Same as item 18-942 but 75 x 63 x 75 mm dia. Each 18-950 1307
Same as item 18-933 to 18-935, 18-942 to 18-944, but fixing Each 18-951 52
only.
Same as item 18-936 to 18-938, 18-945 to 18-946, but fixing Each 18-952 86
only.
Same as item 18-939 to 18-941, 18-947 to 18-950, but fixing Each 18-953 104
only.
Add to item 18-933 to 18-935, 18-942 to 18-944 or 18-951, if Each 18-954 39
removal only.
Add to item 18-936 to 18-938, 18-945 to 18-946 or 18-952 if Each 18-955 65
removal only.
Add to item 18-939 to 18-941, 18-947 to 18-950 or 18-953, if Each 18-956 78
removal only.
Male Threaded - Tee
Male Threaded Tee, 20 mm x 15 mm dia for PPR pipe, supply Each 18-957 335
and fixing.
Same as item 18-957, but 20 x 20 mm dia. Each 18-958 507
Same as item 18-957, but 25 x 15 mm dia. Each 18-959 245
Same as item 18-957, but 25 x 20 mm dia. Each 18-960 322
Same as item 18-957, but 32 x 20 mm dia. Each 18-961 372
Same as item 18-957, but 32 x 25 mm dia. Each 18-962 509
Female Threaded - Tee
Female Threaded Tee, 20 mm x 15 mm dia for PPR pipe, Each 18-963 210
supply and fixing.
Same as item 18-963, but 20 x 20 mm dia. Each 18-964 253
Same as item 18-963, but 25 x 15 mm dia. Each 18-965 195
Same as item 18-963, but 25 x 20 mm dia. Each 18-966 243
Same as item 18-963, but 32 x 20 mm dia. Each 18-967 335
Same as item 18-963 but 32 x 25 mm dia. Each 18-968 425
Same as item 18-957 to18-960, 18-963 to 18-966, but fixing Each 18-969 52
only.
Same as item 18-961 to18-962, 18-967 to 18-968, but fixing Each 18-970 86
only.
Add to item 18-957 to18-960, 18-963 to 18-966 or 18-969, if Each 18-971 39
removal only.
Add to item 18-961 to18-962, 18-967 to 18-968 or 18-970, if Each 18-972 65
removal only.
Elbow
Elbow 20mm dia 90° for PPR pipe, supply and fixing. Each 18-973 60
Same as item 18-973, but 25 mm dia. Each 18-974 62
Same as item 18-973, but 32 mm dia. Each 18-975 84
Same as item 18-973, but 40 mm dia. Each 18-976 151
Same as item 18-973, but 50 mm dia. Each 18-977 277
Same as item 18-973, but 63 mm dia. Each 18-978 471
Same as item 18-973, but 75 mm dia. Each 18-979 992
Same as item 18-973, but 90 mm dia. Each 18-980 1891
Same as item 18-973, but 110 mm dia. Each 18-981 2705
Elbow 20 mm dia, 45° for PPR pipe, supply and fixing. Each 18-982 62
Same as item 18-982, but 25 mm dia. Each 18-983 84
Same as item 18-982, but 32 mm dia. Each 18-984 87
Same as item 18-982, but 40 mm dia. Each 18-985 151
Same as item 18-982, but 50 mm dia. Each 18-986 277
Same as item 18-982, but 63 mm dia. Each 18-987 471
Same as item 18-982, but 75 mm dia. Each 18-988 865
Same as item 18-982, but 90 mm dia. Each 18-989 1572
Male Threaded - 90° Elbow
Male Threaded 90° Elbow, 20 x 15 mm dia for PPR pipe, Each 18-990 257
supply and fixing.
Same as item 18-990, but 20 x 20 mm dia. Each 18-991 300
Same as item 18-990, but 25 x 15 mm dia. Each 18-992 330
Same as item 18-990, but 25 x 20 mm dia. Each 18-993 340
Same as item 18-990, but 32 x 20 mm dia. Each 18-994 355
Same as item 18-990, but 32 x 25 mm dia. Each 18-995 491
Female Threaded - 90° Elbow
Supply and fixing of Female Threaded 90° Elbow, 20 x 15 mm Each 18-996 187
dia, for PPR pipe,
Same as item 18-996, but 20 x 20 mm dia. Each 18-997 237
Same as item 18-996, but 25 x 15 mm dia. Each 18-998 162
Same as item 18-996, but 25 x 20 mm dia. Each 18-999 233
Same as item 18-996 but 32 x 20 mm dia. Each 18-1000 317
Same as item 18-996 but 32 x 25 mm dia. Each 18-1001 398
Same as item 18-973 to 18-975, 18-982 to 18-984, 18-990 to Each 18-1002 35
18-992, or 18-996 to 18-998, but fixing only.

Same as item 18-976 to 18-978, 18-985 to 18-987, 18-993 to Each 18-1003 69


18-995 or 18-999 to 18-1001, but fixing only.

Same as item 18-979 to 18-981 or 18-988 to 18-989, but Each 18-1004 86


fixing only
Add to item 18-973 to 18-975, 18-982 to 18-984, 18-990 to Each 18-1005 26
18-992, 18-996 to 18-998 or 18-1002, if removal only.

Add to item 18-976 to 18-978, 18-985 to 18-987, 18-993 Each 18-1006 52


to18-995, 18-999 to 18-1001 or 18-1003, if removal only.

Add to item 18-979 to 18-981, 18-988 to 18-989 or 18-1004, Each 18-1007 65


if removal only.
Ball Tap With Handle
Ball Tap with handle, 20 mm dia for PPR pipe, supply and Each 18-1008 541
fixing.
Same as item 18-1008, but 25 mm dia. Each 18-1009 689
Same as item 18-1008, but 32 mm dia. Each 18-1010 1125
Same as item 18-1008, but 40 mm dia. Each 18-1011 2015
Same as item 18-1008, but 50 mm dia. Each 18-1012 4735
Same as item 18-1008, but 63 mm dia. Each 18-1013 4831
Screw Tap With Handle
Screw tap with handle, 20 mm dia for PPR pipe, supply and Each 18-1014 786
fixing.
Same as item 18-1014, but 25 mm dia. Each 18-1015 805
Same as item 18-1014, but 32 mm dia. Each 18-1016 1175
Same as item 18-1014, but 40 mm dia. Each 18-1017 1993
Same as item 18-1014, but 50 mm dia. Each 18-1018 5348
Same as item 18-1014, but 63 mm dia. Each 18-1019 7389
Same as item 18-1008 to 18-1010 or 18-1014 to 18-1016, but Each 18-1020 35
fixing only.
Same as item 18-1011 to 18-1013 or 18-1017 to 18-1019, but Each 18-1021 69
fixing only.
Add to item 18-1008 to 18-1010, 18-1014 to 18-1016 or 18- Each 18-1022 26
1020, if removal only.
Add to item 18-1011 to 18-1013, 18-1017 to 18-1019 or 18- Each 18-1023 52
1021, if removal only.
Male Threaded - Adapter
Male Threaded Adaptor, 20 x 15 mm dia for PPR pipe, supply Each 18-1024 196
and fixing.
Same as item 18-1024, but 20 x 20 mm dia. Each 18-1025 208
Same as item 18-1024, but 25 x 15 mm dia. Each 18-1026 221
Same as item 18-1024, but 25 x 20 mm dia. Each 18-1027 263
Same as item 18-1024, but 32 x 20 mm dia. Each 18-1028 345
Same as item 18-1024, but 32 x 25 mm dia. Each 18-1029 467
Same as item 18-1024, but 40 x 32 mm dia. Each 18-1030 1225
Same as item 18-1024, but 50 x 40 mm dia. Each 18-1031 1914
Same as item 18-1024, but 63 x 50 mm dia. Each 18-1032 3062
Same as item 18-1024, but 63 x 40 mm dia. Each 18-1033 2368
Female Threaded – Adapter
Female Threaded Adaptor, 20 x 15 mm dia for PPR pipe, Each 18-1034 193
supply and fixing.
Same as item 18-1034, but 20 x 20 mm dia. Each 18-1035 239
Same as item 18-1034, but 25 x 15 mm dia. Each 18-1036 174
Same as item 18-1034, but 25 x 20 mm dia. Each 18-1037 205
Same as item 18-1034, but 32 x 25 mm dia. Each 18-1038 387
Same as item 18-1034, but 40 x 32 mm dia. Each 18-1039 642
Same as item 18-1034, but 50 x 40 mm dia. Each 18-1040 1196
Same as item 18-1034, but 63 x 50 mm dia. Each 18-1041 1953
Same as item 18-1034, but 63 x 40 mm dia. Each 18-1042 1464
Same as item 18-1034, but 75 x 63 mm dia. Each 18-1043 2732
Same as item 18-1024 to 18-1027, 18-1034 to 18-1037, but Each 18-1044 52
fixing only.
Same as item 18-1028 to 18-1031, 18-1038 to 18-1040, but Each 18-1045 86
fixing only.
Same as item 18-1032 to 18-1033 or 18-1041, 18-1043 but Each 18-1046 104
fixing only.
Add to item 18-1024 to 18-1027, 18-1034 to 18-1037 or 18- Each 18-1047 39
1044, if removal only.
Add to item 18-1028 to 18-1031, 18-1038 to 18-1040 or 18- Each 18-1048 65
1045, if removal only.
Add to item 18-1032 to 18-1033, 18-1041 to 18-1043, or 18- Each 18-1049 78
1046 if removal only.
Cross piece, 20 mm dia for PPR pipe, supply and fixing. Each 18-1050 113
Same as item 18-1050, but 25 mm dia. Each 18-1051 129
Cross Tee, 20 mm dia for PPR pipe, supply and fixing Each 18-1052 129
Same as Item 18-1052 but 25 mm dia. Each 18-1053 161
Same as Item 18-1052 but 32 mm dia. Each 18-1054 214
Shut Off Valve with Handle
Shut off valve with handle, 20 mm dia for PPR pipe, supply Each 18-1055 3189
and fixing.
Same as item 18-1055, but 25 mm dia. Each 18-1056 5032
Same as item 18-1050 to 18-1056, but fixing only. Each 18-1057 52
Add to item 18-1050 to 18-1056 or 18-1057, if removal only. Each 18-1058 39

Steel Sch 40 Gate, valve flanged and drilled to B.S Table 18-1- Each 18-1059 10467
10, Rising Steam, complete with packing sheet 40mm dia,
supply and fixing.
Same as item 18-1059 but 50mm dia. Each 18-1060 12467
Same as item 18-1059 but 80mm dia. Each 18-1061 18611
Same as item 18-1059 but 100mm dia. Each 18-1062 24113
Same as item 18-1059 but 150mm dia. Each 18-1063 41113
Same as item 18-1059 to 18-1063 but fixing only. Each 18-1064 288
Add to item 18-1059 to 18-1063 or 18-1064, if removal only. Each 18-1065 144

Description Unit SI No. Rate (Rs)


Centrifugal Pumping Set
Centrifugal Pumping set, AC, electric motor driven, 400 volts, Each 19-1 40189
3 phase, 50 cycles, 1 HP, mounted on a common channel
base, total head 20/25 Motor, efficiency IE-2, Insulation class
’F’, enclosure characteristics IP-55, supply and fixing.

Same as item 19-1, but 2 HP motor, for 25/30 M head. Each 19-2 41630
Centrifugal Pumping set, AC, electric motor driven, 220 /230 Each 19-3 36541
V, SP, 1 HP, 50 cycles, mounted on a common channel base,
total head 20/25 Motor efficiency IE-2, insulation class ’F’,
enclosure characteristics IP-55, supply and fixing.

Same as item 19-3, but with 1/2 HP motor for 10/15 M head. Each 19-4 31790

Same as item 19-1, but fixing only. Each 19-5 518


Same as item 19-2, but fixing only. Each 19-6 638
Same as item 19-3, but fixing only. Each 19-7 518
Same as item 19-4, but fixing only. Each 19-8 518
Add to item 19-1 or 19-5, if removal only. Each 19-9 388
Add to item 19-2 or 19-6, if removal only. Each 19-10 478
Add to item 19-3 or 19-7, if removal only. Each 19-11 388
Add to item 19-4 or 19-8, if removal only. Each 19-12 388
Centrifugal Pumping set with A.C electric motor, 400V, 3 Each 19-13 405423
phase, 5 HP, 50 cycles, motor and pump directly coupled and
mounted on common bed plate/ channel base, duly aligned,
head 10-13 M, Capacity 100 - 200 GPM, 1450 RPM,
Complete, with anchoring bolts/nuts, Motor efficiency IE-2,
Insulation class ’F’, enclosure characteristics IP-55, supply and
fixing.
Same as item 19-13, but capacity above 200 upto 300 GPM, Each 19-14 487923
head 11-15 M 10 HP.
Same as item 19-13, but capacity above 300 upto 550 GPM, Each 19-15 574901
head 12-17 M, 15 HP.
Same as item 19-13, but capacity 100 to 210 GPM, head 27- Each 19-16 461232
33M, 2850/2900 RPM, 15 HP.
Same as item 19-16, but capacity 150 to 250 GPM, head 38 - Each 19-17 465177
41 M, 15 HP.
Same as item 19-16, but capacity 300 GPM, head 35 M, 15 Each 19-18 477363
HP.
Same as item 19-13, but fixing only. Each 19-19 1380
Same as item 19-14, but fixing only. Each 19-20 1380
Same as item 19-15, but fixing only. Each 19-21 1898
Same as item 19-16, but fixing only. Each 19-22 1553
Same as item 19-17, but fixing only. Each 19-23 1898
Same as item 19-18, but fixing only. Each 19-24 2243
Add to item 19-13 or 19-19, if removal only. Each 19-25 1035
Add to item 19-14 or 19-20, if removal only. Each 19-26 1035
Add to item 19-15 or 19-21, if removal only. Each 19-27 1423
Add to item 19-16 or 19-22, if removal only. Each 19-28 1164
Add to item 19-17 or 19-23, if removal only. Each 19-29 1423
Add to item 19-18 or 19-24, if removal only. Each 19-30 1682
Tube Well Boring
In any soil, drilling bore hole, 375 mm dia, employing Reverse Metre 19-31 4330
Rotary, Hydraulic Percussion method, bore upto 50 M depth,
complete.
Same as item 19-31, but 450 mm dia bore hole. Metre 19-32 4920
Same as item 19-31, but 600 mm dia bore hole. Metre 19-33 5820
In any soil, drilling bore hole, 375 mm dia, employing Reverse Metre 19-34 5117
Rotary, Hydraulic / Percussion method, bore more than 50M
but upto 100 M depth, complete.
Same as item 19-34, but 450 mm dia bore hole. Metre 19-35 5700
Same as item 19-34, but 600 mm dia bore hole. Metre 19-36 6593
In any soil, drilling a bore hole 375 mm dia, employing Metre 19-37 5820
Reverse Rotary, Hydraulic / Percussion method, bore more
than 100 M but upto 150M depth complete.
Same as item 19-37, but 450 mm dia bore hole. Metre 19-38 6396
Same as item 19-37, but 600 mm dia bore hole. Metre 19-39 7080
In any soil, drilling bore hole 375 mm dia, employing Reverse Metre 19-40 6494
Rotary/ Hydraulic / Percussion method, bore beyond 150 M
depth, complete.
Same as item 19-40, but 450 mm dia bore hole. Metre 19-41 6684
Same as item 19-40, but 600 mm dia bore hole. Metre 19-42 7860
In any soil, drilling Trial bore hole 150 mm dia, bore up to 50 Metre 19-43 3780
M depth.
Same as item 19-43, but bore above 50 M and upto 100 M Metre 19-44 4200
depth
Same as item 19-43, but bore above 100 M and upto 150 M Metre 19-45 4740
depth
Same as item 19-43, but bore beyond 150 M depth. Metre 19-46 5040
Supply and installation, MS Blind pipe 5 mm thick, 200mm dia Metre 19-47 7042
with welding joints, complete.
Same as item 19-47, but 250 mm dia and 5.5 mm thick. Metre 19-48 9590

Same as item 19-47, but 300 mm dia and 6.35 mm thick. Metre 19-49 12965
Supply and Lowering in Predrilled bore hole 200 mm dia V- Metre 19-50 30605
WIRE V-WEDGE continuous slot, stainless steel, water well
screen proper welded with MS pipe complete in all respect.

Same as item 19-50, but 250 mm dia. Metre 19-51 41047


Same as item 19-50, but 300 mm dia. Metre 19-52 56443
Supply and Lowering in Predrilled bore hole 200mm dia V- Metre 19-53 26058
WIRE V-WEDGE continuous slot, Low Carbon Galvanized Iron
(LCGI), water well screen proper welded with MS pipe
complete in all respect.
Same as item 19-53, but 250 mm dia. Metre 19-54 30915
Same as item 19-53, but 300 mm dia. Metre 19-55 35710
Supply and installation of Bail Plug, 200 mm dia of approved Each 19-56 9872
specifications.
Same as item 19-56, but 250 mm dia. Each 19-57 12685
Same as item 19-56, but 300 mm dia. Each 19-58 15537
Supply and Pouring of Shrouding Gravel of requisite grade, in Metre 19-59 199
annular space between blind pipe/strainer and bore hole
according to specifications for 200 mm dia blind
pipe/strainer.
Same as item 19-59, but for 250 mm dia blind pipe/strainer. Metre 19-60 270

Same as item 19-59, but for 300 mm dia blind pipe/strainer. Metre 19-61 476

Provision of Sanitary Seal of approved design and Metre 19-62 1028


specification for 200 mm dia blind pipe.
Same as item 19-62, but for 250 mm dia blind pipe. Metre 19-63 1398
Same as item 19-62, but for 300 mm dia blind pipe. Metre 19-64 2610
Develop, Test and Sterilize tube well in accordance with Each 19-65 132000
approved procedure, 200 mm dia
Same as item 19-65, but 250 mm dia. Each 19-66 168000
Same as item 19-65, but 300 mm dia. Each 19-67 168000
Deep Well – Turbine / Pump
Pumping set Deep Well Turbine, hollow shaft, AC electric Each 19-68 1264665
motor driven, 400 volts 3 phase, 50 cycles, complete with
shafts, column pipes, motor and auto star delta starter, pump
capacity 0.50-0.70 cusec, upto 46 M head, pump setting
upto 18 M with electric motor, 15 HP, motor efficiency IE2,
insulation class ’F’, enclosure characteristics IP-55, supply and
fixing.
Same as item 19-68, but pump capacity above 0.7 and upto Each 19-69 1359195
1.0 cusec at 46 M head, pump setting upto 18 M, with 20 HP
motor.
Same as item 19-68, but pump capacity 1.0-1.25 cusec at 35- Each 19-70 1504875
47 M head, pump setting upto 18 M with 30 HP motor.
Same as item 19-68, but pump capacity above 1.0 cusec upto Each 19-71 1505328
1.5 cusec at 46 M head, pump setting upto 18 M with 30 HP
motor.
Same as item 19-68, but pump capacity above 0.5 cusec upto Each 19-72 1608798
0.75 cusec at 47-61 M head, pump setting upto 46 M, with
motor 30 HP.
Same as item 19- 68, but pump capacity upto 0.5-0.8 cusec at Each 19-73 1800765
60-78 M head, pump setting upto 46 M with 30 HP motor.

Same as item 19-68, but pump capacity above 1.0 and upto Each 19-74 2783686
1.5 cusec, 63-92 M head, pump setting upto 46 M with
motor 60 HP.
Same as item 19-68, but pump capacity above 1.5 and upto Each 19-75 2667588
2.0 cusec, 40-62 M head, pump setting upto 46 M, with
motor 50 HP
Same as item 19-68, but pump capacity above 1.0 and upto Each 19-76 2541648
1.5 cusec, 47-70 M head, pump setting upto 46 M with
motor 40 HP.
Same as item 19-68, but pump capacity above 0.80 and upto Each 19-77 2289918
1.0 cusec, 68-85 M head, pump setting upto 46 M with
motor 30 HP.
Same as item 19-68, but pump capacity above 2.0 and upto Each 19-78 2676628
2.25 cusec, 40-50 M head, pump setting upto 46 M with
motor 60 HP.
Same as item 19-68, but pump capacity above 2.0 and upto Each 19-79 3019008
2.25 cusec, 58-78 M head, pump setting up to 46 M with
motor 100 HP.
Same as item 19-68, but pump capacity above 0.75 and upto Each 19-80 2315565
1.0 cusec, 66-88 M head, pump setting upto 46 M with
motor 40 HP.
Same as item 19-68, but fixing only. Each 19-81 3945
Same as item 19-69, but fixing only. Each 19-82 4875
Same as item 19-70, but fixing only. Each 19-83 4875
Same as item 19-71, but fixing only. Each 19-84 5805
Same as item 19-72, but fixing only. Each 19-85 5805
Same as item 19-73, but fixing only. Each 19-86 5805
Same as item 19-74, but fixing only. Each 19-87 5805
Same as item 19-75, but fixing only. Each 19-88 7665
Same as item 18-76, but fixing only. Each 19-89 5805
Same as item 19-77, but fixing only. Each 19-90 4875
Same as item 19-78, but fixing only. Each 19-91 7665
Same as item 19-79, but fixing only. Each 19-92 5805
Same as item 19-80, but fixing only. Each 19-93 5805
Add to item 19-68 or 19-81, if removal only. Each 19-94 2959
Add to item 19-69 or 19-82, if removal only. Each 19-95 3656
Add to item 19-70 or 19-83, if removal only. Each 19-96 3656
Add to item 19-71 or 19-84, if removal only. Each 19-97 4354
Add to item 19-72 or 19-85, if removal only. Each 19-98 3656
Add to item 19-73 or 19-86, if removal only. Each 19-99 4354
Add to item 19-74 or 19-87, if removal only. Each 19-100 4354
Add to item 19-75 or 19-88, if removal only. Each 19-101 5749
Add to item 19-76 or 19-89, if removal only. Each 19-102 4354
Add to item 19-77 or 19-90, if removal only. Each 19-103 3656
Add to item 19-78 or 19-91, if removal only. Each 19-104 5749
Add to item 19-79 or 19-92, if removal only. Each 19-105 4354
Add to item 19-80 or 19-93, if removal only. Each 19-106 4354
Extra Column Pipe
Extra column pipe, with motor shaft (3 M length each), Each 19-107 57210
complete with bearing sockets, threaded coupling shaft,
sleeve and rubber bearing, complete set (125 mm x 3 m x 25
mm), supply and fixing.
Same as item 19-107, but size (150 mm x 3 m x 30 mm). Each 19-108 78690

Same as item 19-107, but size (150 mm x 3 m x 35 mm). Each 19-109 78690

Same as item 19-107, but size (175 mm x 3 m x 35 mm). Each 19-110 110805

Same as item 19-107, but size (175 mm x 3 m x 45 mm). Each 19-111 142065

Same as item 19-107, but fixing only. Each 19-112 930


Same as item 19-108, but fixing only. Each 19-113 930
Same as item 19-109, but fixing only. Each 19-114 930
Same as item 19-110, but fixing only. Each 19-115 1395
Same as item 19-111, but fixing only. Each 19-116 1395
Add to item 19-107 or 19-112, if removal only. Each 19-117 698

Add to item 19-108 or 19-113, if removal only. Each 19-118 698

Add to item 19-109 or 19-114, if removal only. Each 19-119 698

Add to item 19-110 or 19-115, if removal only. Each 19-120 1046

Add to item 19-111 or 19-116, if removal only. Each 19-121 1046

Submersible Pump
Pumping set submersible, with AC electric motor driven, 400 Each 19-122 1533075
V, 3 phase, 50 cycles, complete with pump, motor, cable,
column pipes, motor control unit, pump capacity 0.5 cusec
upto 97 M head, pump setting 60 M with 25 HP motor, 2900
RPM, motor efficiency IE2, insulation class ’F’, enclosure
characteristics IP-68, supply and fixing.
Same as item 19-122, but pump capacity 0.5 cusec at 97-106 Each 19-123 1482675
M head, pump setting 60 M, with 30 HP motor, 2900 RPM.

Same as item 19-122, but pump capacity 1.0 cusec at 88-97 Each 19-124 2118476
M head, pump setting 50 M, with 50 HP motor, 2900 RPM.

Same as item 19-122, but pump capacity 1.0 cusec at 97-105 Each 19-125 2668556
M head, pump setting 60 M with 60 HP motor, 2900 RPM.

Same as item 19-122, but pump capacity 1.0 to 1.25 cusec, Each 19-126 2668556
96-110 M head, pump setting 60 M, with 60 HP motor, 2900
RPM.
Same as item 19-122, but pump capacity 1.50 cusec and upto Each 19-127 3017988
88 M head, pump setting 60 M with 75 HP motor, 2900 RPM.

Same as item 19-122, but pump capacity 1.25-1.50 cusec at Each 19-128 3017988
95-105 M head, pump setting 60 M with 75 HP motor 2900
RPM.
Same as item 19-122, but pump capacity 1.50 to 1.75 cusec Each 19-129 3018453
at 88-102 M head, pump setting 60 M with 75 HP motor,
2900 RPM.
Same as item 19-122, but pump capacity 1.75 cusec at 82-91 Each 19-130 3018453
M head, pump setting 60 M with 85 HP motor 2900 RPM.

Same as item 19-122, but fixing only. Each 19-131 3015


Same as item 19-123, but fixing only. Each 19-132 3015
Same as item 19-124, but fixing only. Each 19-133 3248
Same as item 19-125, but fixing only. Each 19-134 3248
Same as item 19-126, but fixing only. Each 19-135 3248
Same as item 19-127, but fixing only. Each 19-136 3480
Same as item 19-128, but fixing only. Each 19-137 3480
Same as item 19-129, but fixing only. Each 19-138 3945
Same as item 19-130, but fixing only. Each 19-139 3945
Add to item 19-122 or 19-131, if removal only. Each 19-140 2261

Add to item 19-123 or 19-132, if removal only. Each 19-141 2261

Add to item 19-124 or 19-133, if removal only Each 19-142 2436

Add to item 19-125 or 19-134, if removal only Each 19-143 2436

Add to item 19-126 or 19-135, if removal only Each 19-144 2436

Add to item 19-127 or 19-136, if removal only Each 19-145 2610

Add to item 19-128 or 19-137, if removal only Each 19-146 2610


Add to item 19-129 or 19-138, if removal only Each 19-147 2959

Add to item 19-130 or 19-139, if removal only Each 19-148 2959

Chlorinators
Gas Chlorinator "Imported" direct cylinder mounted, all Each 19-149 266499
vacuum operated, max capacity 25-50 pounds per day (ppd),
feed gas chlorination ratio 20:1, with all operational standard
accessories, make Pennsylvania USA , Model 201-CI, supply
and fixing.
Same as item 19-149, but Model 481-CI Each 19-150 169576
Same as item 19-149, but fixing only. Each 19-151 345
Same as item 19-150, but fixing only. Each 19-152 345
Add to item 19-149 or 19-151, if removal only. Each 19-153 259

Add to item 19-150 or 19-152, if removal only. Each 19-154 259

Multistage Centrifugal mono-block chlorinator, booster Each 19-155 67035


pumping set, size 40 mm x 32 mm dia suction /delivery
having gunmetal impellers, stainless steel shaft, stuffing box,
fitted to 3 HP 380/400 V, 50 cycles, 3 phase, AC electric
motor on common shaft, capacity 15 gpm at 41 M total
discharge head, motor efficiency IE2, insulation class ’F’,
enclosure characteristics IP-55 supply and fixing.

Same as item 19-155, but motor capacity 5 HP. Each 19-156 85035

Same as item 19-155, but fixing only. Each 19-157 1035


Same as item 19-156, but fixing only. Each 19-158 1035
Add to item 19-155, 19-156, 19-157 or 19-158, if removal Each 19-159 776
only.
Gas Chlorinator cylinder mounted all vacuum operated, feed Each 19-160 77268
ratio 20:1, capacity and measuring upto 100 ppd, consisting
of vacuum regulator with chlorine gas flow meter, gate valve,
chlorine supply indicator and vent, manually adjustable flow
rate, vent and vacuum tubing, vacuum ejector with diffuser
and water back-flow, check valve, complete all as specified,
supply and fixing.

Hypo-Chlorinator, Solenoid type having Liquid chlorine Each 19-161 93688


feeding capacity 20 gpd at 150 psi fitted with flow rate
control knob manually adjustable 0-100%, operated at 220 /
240V, 50 Hz, diaphragm type of non-corrosive material with
standard suction/discharge tubing, injector, pressure auto
relief valve, anti-siphon valve, solution storage tank of 50 gal
capacity PE/PVC with stand duly painted as specified, supply
and fixing.
Same as item 19-160, but fixing only. Each 19-162 345
Same as item 19-161, but fixing only Each 19-163 1380
Add to item 19-160 or 19-162 if removal only. Each 19-164 259
Add to item 19-161 or 19-163, if removal only. Each 19-165 690

Chlorine Gas Cylinder


Chlorine Gas cylinder, Imported Approved Type 68 kg Each 19-166 107749
capacity, bottle type, with first filling of liquid chlorine after
Hydraulic testing, supply and fixing.
Same as item 19-166 but fixing only. Each 19-167 56
Add to item 19-166 or 19-167, if removal only. Each 19-168 42

Reciprocating Pump
Reciprocating pump (donkey pump) 1450 RPM, driven with Each 19-169 11123
single phase electric motor 1/2 HP, mounted on frame and
fixed complete head 15-40 M, discharge 34-29 lit/min, supply
and fixing.
Same as item 19-169, but heavy duty driven by electric motor Each 19-170 31823
2 HP, SP head 30-70 M, discharge 50-39 lit/min.

Same items as 19-169 or 19-170, but fixing only. Each 19-171 803
Add to item 19-169, 19-170 or 19-171, if removal only. Each 19-172 602

Motor Electric
Motor electric, Motor Efficiency, single phase, 220V, 1/2 HP, Each 19-173 11153
1425 /1450 RPM, supply and fixing.
Motor electric, Motor Efficiency IE-2, Insulation Class F, Each 19-174 16673
Enclosure characteristic IP-55, single phase, 220V, 2 HP, 1425
/1450 RPM, supply and fixing.
Same as item 19-173 or 19-174, but fixing only. Each 19-175 173
Add to item 19-173, 19-174 or 19-175, if removal only. Each 19-176 129

Sluice Valve – Oil Quality


Cast Steel Gate/Sluice valve, flanged and drilled to BS, Table Each 19-177 14670
18-1-10, rising stem, oil quality, Class-150 lbs complete with
packing sheet, 25 mm dia, supply and fixing.

Same as item 19-177, but 40 mm dia. Each 19-178 16707


Same as item 19-177, but 50 mm dia. Each 19-179 17830
Same as item 19-177, but 62 mm dia. Each 19-180 23759
Same as item 19-177, but 75/80 mm dia. Each 19-181 29094
Same as item 19-177, but 100 mm dia. Each 19-182 35880
Same as item 19-177, but 150 mm dia. Each 19-183 49352
Same as item 19-177 to 19-179, but fixing only. Each 19-184 561
Same as item 19-180 to 19-181, but fixing only. Each 19-185 733
Same as item 19-182 to 19-183, but fixing only. Each 19-186 1336
Add to item 19-177 to 19-179 or 19-184, if removal only. Each 19-187 259

Add to items 19-180 to 19-181 or 19-185, if removal only. Each 19-188 388

Add to items 19-182 to 19-183 or 19-186, if removal only. Each 19-189 698

Disinfection of Water Pipe Line


Disinfection of water pipe line, 25 mm dia with mixture of Metre 19-190 10
clear water and liquid Chlorine, as specified in Para 18.2.9.

Same as item 19-190, but 40 mm dia. Metre 19-191 10


Same as item 19-190, but 50 mm dia. Metre 19-192 12
Same as item 19-190, but 65 mm dia. Metre 19-193 14
Same as item 19-190, but 80 mm dia. Metre 19-194 16
Same as item 19-190, but 100 mm dia. Metre 19-195 20
Same as item 19-190, but 150 mm dia. Metre 19-196 34
Same as item 19-190, but 200 mm dia. Metre 19-197 53
Same as item 19-190, but 250 mm dia. Metre 19-198 77
Same as item 19-190, but 300 mm dia. Metre 19-199 107
Mono Block Pumping Set
Mono Block Pumping Set (cast iron body) single Phase, Each 19-200 11603
electric Motor, with copper winding, 1/2 HP, max suction 6
M, head 8-20 Metre, discharge 20-55 Lit/Min, supply and
fixing.
Mono Block Pumping Set (cast iron body) single Phase, Each 19-201 15545
electric Motor Efficiency IE-2, Insulation Class F, Enclosure
characteristic IP-55, with copper winding, 1 HP, max suction 6
M, Head 10-24 Metre and discharge 25-70 Ltr/Min supply
and fixing.
Same as item 19-200, 19-201 but fixing only. Each 19-202 803

Add to Item 19-200, 19-201 or 19-202, if removal only. Each 19-203 602

Water purification System


Supply, Fixing testing and commission of water purification Each 19-204 698430
plant system plant capacity 1000 GPH with multimedia filter,
Granular activated carbon filter, Back wash pump, Fine
sediment filter Ultraviolet+sterilizer and stainless steel header
all as specified.
Same as Item 19-204 but 500 GPH. Each 19-205 558510
Same as Item 19-204 but fixing only. Each 19-206 9810
Same as Item 19-205 but fixing only. Each 19-207 4965
Add to item 19-204 to 19-207 if removal only. Each 19-208 4905
Pressure switch complete with all accessories for pumping set Each 19-209 12585
up to 1 HP, supply and fixing.
Same as Item 19-209 but fixing only. Each 19-210 375
Add to item 19-209 to 19-210 if removal only. Each 19-211 188
Description Unit SI No. Rate (Rs)
Soil Waste and Ventilation, Pipes (CI – Spun)
Supply and fix, CI SWV pipe 75 mm bore, all as specified. Metre 20-1 2327

Same as item 20-1, but 100 mm bore. Metre 20-2 2833


Same as item 20-1, but 150 mm bore. Metre 20-3 5202
Supply and fixing CI SWV pipe 75 mm bore but except cost of Metre 20-4 506
pipes.
Same as item 20-4, but 100 mm bore. Metre 20-5 553
Same as item 20-4, but 150 mm bore. Metre 20-6 758
Add to item 20-1 to 20-6 or, if fixed in repair. Metre 20-7 139
Fittings – (CI-Spun) Bends
Supply and fix, CI plain bend 75 mm bore joints filled with Each 20-8 1961
lead, all as specified.
Same as item 20-8, but 100 mm bore. Each 20-9 2500
Same as item 20-8, but 150 mm bore. Each 20-10 5694
Supply and fix, CI plug bend 75 mm bore joints filled with Each 20-11 2291
lead, as specified.
Same as item 20-11 but 100 mm bore. Each 20-12 2680
Same as item 20-11 but 150 mm bore. Each 20-13 6295
Supply and fix, CI plain and plug bends 75 mm bore joints Each 20-14 791
filled with lead, but except cost of plain and plug bends, all as
specified.
Same as item 20-14, but 100 mm bore. Each 20-15 1000
Same as item 20-14, but 150 mm bore. Each 20-16 1525
Supply and fix, CI plain T 75 mm bore joint filled with lead, all Each 20-17 2472
as specified.
Same as item 20-17, but 100 mm bore. Each 20-18 3559
Same as item 20-17, but 150 mm bore. Each 20-19 7669
Supply and fix, CI, plug T 75 mm joint filled with lead, all as Each 20-20 2804
specified.
Same as item 20-20, but 100 mm bore. Each 20-21 3829
Same as item 20-20, but 150 mm bore. Each 20-22 8419
Supply and fix, CI, Y-T 75 mm bore joint filled with lead, all as Each 20-23 3281
specified.
Same as item 20-23, but 100 mm bore. Each 20-24 3949
Same as item 20-23, but 150 mm bore. Each 20-25 8419
Supply and fix, CI, plain T, plug T and Y-T 75mm bore, joints Each 20-26 1272
filled with lead, but except cost of plain tee, plug tee and Yee
tee.
Same as item 20-26, but 100 mm bore. Each 20-27 1579
Same as item 20-26, but 150 mm bore. Each 20-28 2449
Reduced Fittings (CI – Spun)
Supply and fix, CI reducer socket 100 mm x 50 mm bore, Each 20-29 2372
joints filled with lead, as specified.
Same as item 20-29 but 100 mm x 75 mm bore. Each 20-30 2641
Supply and fix, CI reducer socket 100 mm x 50 mm / 75 mm Each 20-31 1000
bore, joints filled with lead, but except cost of reducer socket
to item 20-29 and 20-30, as specified.
Supply and fix, CI reducer plain T 100 mm x 50 mm / 75 mm Each 20-32 3252
bore, joints filled with lead, as specified.
Same as item 20-32 but plug T. Each 20-33 3522
Same as item 20-32 but Y-T. Each 20-34 3642
Supply and fix, CI reducer T 100 mm x 50 mm / 75 mm bore, Each 20-35 1272
joints filled with lead, but except cost of reducer T to item 20-
32, 20-33 and 20-34, as specified.
Cowls – (CI – Spun)
Supply and fix, Vent guard / Cowl over out let of down pipes Each 20-36 1100
or top of ventilating pipes etc., fixed complete, dome or
balloon pattern, 75 mm bore.
Same as item 20-36, but 100 mm bore. Each 20-37 1227
Same as item 20-36 or 20-37, but fixing only. Each 20-38 50
Add to item 20-36 to 20-38 if fixed in repair. Each 20-39 30
P/S Traps (CI – Spun)
Supply and fix CI Spun P-trap, 100 mm dia, all as specified. Each 20-40 2527

Same as item 20-40, but 75 mm dia. Each 20-41 1923


Supply and fix CI Spun S-trap, 100 mm dia. Each 20-42 4042
Same as item 20-42, but 75 mm dia. Each 20-43 3957
Same as item 20-42, but 50 mm dia. Each 20-44 3868
uPVC – Soil and Waste Pipes
Supply and fix, u-PVC Soil and waste pipe 50 mm dia, Metre 20-45 360
complete with Z joint and rubber ring, all as specified.
Same as item 20-45 but 75 mm dia. Metre 20-46 512
Same as item 20-45 but 110 mm dia. Metre 20-47 727
Same as item 20-45 but 160 mm dia. Metre 20-48 1028
Supply and fix, u-PVC, Soil and waste pipe 50 mm dia, Metre 20-49 363
complete, with plain end and solvent cement joint, all as
specified.
Same as item 20-49, but 75 mm dia. Metre 20-50 587
Same as item 20-49, but 110 mm dia. Metre 20-51 773
Same as item 20-49, but 160 mm dia. Metre 20-52 1420
Same as item 20-49, but 200 mm dia. Metre 20-53 1552
Same as item 20-49, but 300 mm dia. Metre 20-54 2374
uPVC – Vent Pipes
Supply and fix, u-PVC Vent pipe 50 mm dia, complete with Z Metre 20-55 337
joint and rubber ring, all as specified.
Same as item 20-55 but 75 mm dia. Metre 20-56 512
Same as item 20-55, but 110 mm dia. Metre 20-57 727
Supply and fix, u-PVC Vent pipe 50 mm dia, complete with Metre 20-58 363
plain end and solvent cement joint, all as specified.
Same as item 20-58, but 75 mm dia. Metre 20-59 587
Same as item 20-58, but 110 mm dia. Metre 20-60 817
Same as item 20-45, 20-49, 20-55, 20-58 but fixing only 50 Metre 20-61 43
mm dia.
Same as item 20-46, 20-50, 20-56, 20-59, but fixing only 75 Metre 20-62 50
mm dia.
Same as item 20-47, 20-51, 20-57, 20-60, but fixing only, 110 Metre 20-63 59
mm dia.
Same as item 20-48, 20-52, 20-53 and 20-54, but fixing only Metre 20-64 79
160 mm, 200 mm, 300 mm dia.
Add to item 20-45, 20-49, 20-55, 20-58, 20-61, if fixed in Metre 20-65 26
repair, 50 mm dia.
Add to item 20-46, 20-50, 20-56, 20-59, 20-62, if fixed in Metre 20-66 30
repair, 75 mm dia.
Add to item 20-47, 20-51, 20-57, 20-60, 20-63, if fixed in Metre 20-67 36
repair, 110 mm dia.
Add to item 20-48, 20-52, 20-53, 20-54, 20-64, if fixed in Metre 20-68 48
repair, 160 mm dia, 200 mm dia, 300 mm dia.
Fittings (uPVC)
Supply and fix, uPVC Elbow/bend, 90° 50 mm dia, complete Each 20-69 175
with Z joint and rubber ring, all as specified.
Same as item 20-69, but 75 mm dia. Each 20-70 298
Same as item 20-69, but 110 mm dia. Each 20-71 447
Same as item 20-69, but 160 mm dia. Each 20-72 1085
Supply and fix, uPVC Elbow/bend, 45° 50 mm, complete with Each 20-73 165
Z joint and rubber ring, all as specified.
Same as item 20-73, but 75 mm dia. Each 20-74 273
Same as item 20-73, but 110 mm dia. Each 20-75 416
Same as item 20-73 , but 160 mm dia. Each 20-76 920
Supply and fix, uPVC Elbow/bend, 90° 50 mm dia, complete Each 20-77 168
with solvent cement joint, all as specified.
Same as item 20-77, but 75 mm dia. Each 20-78 376
Same as item 20-77, but 110 mm dia. Each 20-79 621
Same as item 20-77, but 160 mm dia. Each 20-80 2128
Supply and fix, uPVC Elbow/bend 45°, 50 mm dia., complete Each 20-81 127
with solvent cement joint, all as specified.
Same as item 20-81, but 75 mm dia. Each 20-82 213
Same as item 20-81, but 110 mm dia. Each 20-83 325
Same as item 20-81, but 160 mm dia. Each 20-84 787
Supply and fix, Socket 50 mm dia, complete with Z joint and Each 20-85 147
rubber ring, all as specified.
Same as item 20-85, but 75 mm dia. Each 20-86 248
Same as item 20-85, but 110 mm dia. Each 20-87 339
Same as item 20-85, but 160 mm dia. Each 20-88 769
Supply and fix, Socket 50 mm dia complete with solvent Each 20-89 109
cement joint, as specified.
Same as item 20-89, but 75 mm dia. Each 20-90 188
Same as item 20-89, but 110 mm dia. Each 20-91 248
Same as item 20-89, but 160 mm dia. Each 20-92 636
Supply and fix, Eccentric Reducer 50 mm x 75 mm dia, Each 20-93 208
complete with solvent cement joint, all as specified.
Same as item 20-93 but 50 mm x 110 mm dia. Each 20-94 237
Same as item 20-93 but 75 mm x 110 mm dia. Each 20-95 231
Same as item 20-93 but 110 mm x 160 mm dia. Each 20-96 806
Supply and fix, uPVC Equal T 50 mm dia, complete with Z joint Each 20-97 320
and rubber ring, all as specified.
Same as item 20-97, but 75 mm dia. Each 20-98 573
Same as item 20-97, but 110 mm dia. Each 20-99 745
Supply and fix uPVC Y-T, 50 mm dia, complete with Z joint Each 20-100 389
and rubber ring all as specified.
Same as item 20-100, but 75 mm dia. Each 20-101 616
Same as item 20-100, but 110 mm dia. Each 20-102 814
Same as item 20-100, but 160 mm dia. Each 20-103 2614
Supply and fix, uPVC Equal T, 50 mm dia, complete with Each 20-104 226
solvent cement joint, all as specified.
Same as item 20-104, but 75 mm dia. Each 20-105 438
Same as item 20-104, but 110 mm dia. Each 20-106 563
Same as item 20-104, but 160 mm dia. Each 20-107 2114
Supply and fix, uPVC, Access/ door T 75 mm dia, complete Each 20-108 788
with solvent cement joint, all as specified.
Same as item 20-108, but 110 mm dia. Each 20-109 1824
Supply and fix, uPVC, Y-T, 50 mm dia, complete with solvent Each 20-110 374
cement joint, all as specified.
Same as item 20-110, but 75 mm dia. Each 20-111 780
Same as item 20-110, but 110 mm dia. Each 20-112 1355
Same as item 20-110, but 160 mm dia. Each 20-113 3464
Supply and fix, uPVC Reducer T, 75 mm to 110 mm dia, Each 20-114 704
complete with Z joint and rubber ring, all as specified.
Same as item 20-114 but Reducer Y-T, 75 mm x 110 mm dia. Each 20-115 704

Same as item 20-114 but Reducer Y-T 110 mm x 160 mm dia. Each 20-116 2348

Supply and fix, uPVC Reducer T, 75 mm x 110 mm dia, Each 20-117 390
complete with solvent cement, all as specified.
Same as item 20-117 but 110 mm x 160 mm dia. Each 20-118 902
Supply and fix, uPVC Reducer Y-T, 110 mm x 160 mm dia, Each 20-119 1502
complete with solvent cement joint, all as specified.

Same as item 20-119 but 75 mm x 110 mm dia. Each 20-120 522


Same as item 20-119 but 75 mm x 160 mm dia. Each 20-121 1318
Fixing only uPVC, bend elbow, socket, eccentric reducer etc. Each 20-122 43
50 mm dia.
Same as item 20-122, but 75 mm dia. Each 20-123 50
Same as item 20-122, but 110 mm dia. Each 20-124 60
Same as item 20-122, but 160 mm dia. Each 20-125 79
Add to item 20-122, but if fixed in repair. Each 20-126 26
Add to item 20-123, but if fixed in repair. Each 20-127 30
Add to item 20-124, but if fixed in repair. Each 20-128 36
Add to item 20-125, but if fixed in repair. Each 20-129 48
Fixing only, uPVC, Equal T, Y-T, Reducer T and T etc. 50 mm Each 20-130 86
dia.
Same as item 20-130, but 75 mm dia. Each 20-131 99
Same as item 20-130, but 110 mm dia. Each 20-132 119
Same as item 20-130, but 160 mm dia. Each 20-133 158
Add to item 20-130, but if fixed in repair. Each 20-134 51
Add to item 20-131, but if fixed in repair. Each 20-135 59
Add to item 20-132, but if fixed in repair. Each 20-136 71
Add to item 20-133, but if fixed in repair. Each 20-137 96
Supply and fix, uPVC Vent Cowl 50 mm dia on top of Each 20-138 107
ventilating pipes.
Same as item 20-138 but 75 mm dia. Each 20-139 125
Same as item 20-138 but 110 mm dia. Each 20-140 143
Same as item 20-138 to 20-140, but fixing only. Each 20-141 50
Add to item 20-138 to 20-141, if fixed in repair. Each 20-142 30
Supply and fix, uPVC Floor Trap, 100 mm dia. Each 20-143 876
Supply and fix, uPVC P-trap 75 mm dia. Each 20-144 550
Same as item 20-144 but 100 mm dia. Each 20-145 697
Deduct from items, if rubber ring/ gasket not used, all as Metre 20-146 107
specified.
Deduct from items, if lead not used, all as specified. Metre 20-147 150

Description Unit SI No. Rate (Rs)


RCC - Pipes (BS Specifications)
Supply and fix, RCC pipes 100 mm bore, laid and jointed with Metre 21-1 475
spigot socket or collars, as specified.
Same as item 21-1, but except cost of pipe, collars fittings. Metre 21-2 108

Supply and fix, RCC pipes, 150 mm bore, laid and jointed with Metre 21-3 517
spigot socket or collars, as specified.
Same as Item 21-3, but except cost of pipes, collars fittings. Metre 21-4 175

Supply and fix, RCC pipes 230 mm bore, laid and jointed with Metre 21-5 713
spigot socket or collars, as specified.
Same as Item 21-5, but except cost of pipes, collars fitting. Metre 21-6 218

RCC – Pipes (ASTM Specifications)


Supply and fix, RCC pipes 300 mm bore, laid and jointed with Metre 21-7 1289
spigot socket or tongue and groove joint, include rubber ring,
as specified.
Same as Item 21-7, but 375 mm bore. Metre 21-8 1622
Same as item 21-7, but 450 mm bore. Metre 21-9 1848
Same as item 21-7, but 525 mm bore. Metre 21-10 2442
Same as item 21-7, but 600 mm bore. Metre 21-11 2587
Same as item 21-7, but 675 mm bore. Metre 21-12 3617
Same as item 21-7, but 750 mm bore. Metre 21-13 5243
Same as item 21-7, but 825 mm bore. Metre 21-14 5918
Same as item 21-7, but 900 mm bore. Metre 21-15 7560
Same as item 21-7, but 1050 mm bore. Metre 21-16 9791
Same as item 21-7, but 1200 mm bore. Metre 21-17 13383
Cleaning Eyes
Extra over drains and fittings for surrounding, up turned Each 21-18 998
junction in 450 x 450 x 600 mm of PCC 1:4:8, provide 450mm
x 450 mm x 75 mm PCC 1:4:8 or 65mm self face of cover
stone, set and jointed in CM 1:3.

Surface Gullies
Excavate, to dispose off surplus spoil on site, make good the Each 21-19 2020
surface disturbed, supply (230 mm x 230 mm x 100 mm out
let), surface gullies and bed, and surround in 100mm of PCC
1:4:8, provide 100 mm x 125 mm rounded PCC 1:4:8, curb or
900 mm x 900 mm x100 mm dished PCC 1:4:8, top and 250 x
250 mm galvanized CI, loose grating, complete.

Testing Drains
Provide water and temporary apparatus, test drains till Each 21-20 700
perfect testing using (600 mm to 1800 mm head).
Provide water and temporary apparatus, test manholes, full Each 21-21 1431
depth of manholes, but not exceeding 1800 mm.

Provide apparatus, material, labour etc. and smoke test till Each 21-22 983
perfect testing of soil waste, ventilating pipes and connecting
drain to nearest manhole.
Clearing drains by rodding and well flushing between Each 21-23 1140
manholes not exceeding 30M.
Same as item 21-23, but manholes exceeding 30 M and not Each 21-24 1230
exceeding 92 M.
Manholes
Manholes, complete, rectangular or circular as described, not Cum 21-25 36267
exceeding 600 mm deep from invert to surface of cover,
including main channel, set in CM 1:1, 230 mm thick brick
walls (except manhole cover).
Same as item 21-25, but 300 mm thick stone walls. Cum 21-26 41574
Same as item 21-25, but 230 mm thick poured Concrete Cum 21-27 36230
walls.
Same as item 21-25, but 150 mm thick RCC walls. Cum 21-28 33058
Manholes, complete, rectangular or circular as described, Cum 21-29 30071
exceeding 600 mm deep but not exceeding 1800 mm deep,
with iron steps (in angles 380 mm centres), 230mm thick
brick walls (Except manhole cover).

Same as item 21-29, but 300 mm thick stone walls. Cum 21-30 30499
Same as item 21-29, but 230 mm thick poured Concrete Cum 21-31 29223
walls.
Same as item 21-29, but 150 mm thick RCC walls. Cum 21-32 24184
Manhole Covers
Supply and fix, Manhole CI cover with frame, 450 mm, Each 21-33 3346
circular or rectangular exceeding 7.50kg each, but not
exceeding 10kg/each, set in CM and haunching in Concrete,
as specified.
Taking up or down, manhole cover and frame, and removing Each 21-34 240
to store.
Providing and laying, RCC 1:2:4 Manhole cover (precast) Each 21-35 5960
complete with angle iron frame, embedded in concrete, all as
per Information Sheet # Svcs-341
Supply and fix, siphon traps, glazed ware in PCC 1:4:8, P or S Each 21-36 766
traps, 100 mm dia
Sinking of Well
Sinking of Well, 2.15 M dia, upto 3 M depth, below sub soil Metre 21-37 31750
water level.
Cutting into existing Manholes, for connecting new drains, Each 21-38 533
making good to pipe and rendering, cutting out existing
benching and reforming of benching as required for new
drain, making good to existing wall etc., complete, 100 mm
bore of pipes.
Same as item 21-38, but 150 mm bore of pipes. Each 21-39 610
Same as item 21-38, but 230 mm bore pipes. Each 21-40 687
Cutting into existing manholes for removing branch drains, Each 21-41 441
making good to walls and rendering, cutting out branch
channel, and making good benching complete, 100 mm bore
of pipes.
Same as item 21-41, but 150 mm bore of pipes. Each 21-42 481
Same as item 21-41, but 230 mm bore of pipes. Each 21-43 584
Taking up CC or Glazed ware pipes with or without collars, Metre 21-44 65
including fittings, removing to store or cleaning, and stacking
for relaying, 100 mm bore pipes.
Same as item 21-44, but 150 mm bore pipes. Metre 21-45 101
Same as item 21-44, but 230 mm bore pipes. Metre 21-46 125
Breaking up Glazed ware or RCC drain pipes set in CM and Metre 21-47 47
removing off the Mindef premises, if required, 100 mm bore
of pipes.
Same as item 21-47, but 150 mm bore of pipes. Metre 21-48 72
Same as item 21-47, but 230 mm bore of pipes. Metre 21-49 89
Taking up carefully, drain pipes fit for subsequent reuse, Metre 21-50 47
cleaning and stacking within 30M, 100 mm bore of pipes.

Same as item 21-50, but 150 mm bore of pipes. Metre 21-51 87


Same as item 21-50, but 230 mm bore of pipes. Metre 21-52 107
Breaking up gully traps, disconnecting traps etc., set in Each 21-53 83
Concrete and removing off the Mindef premises, if required,
100 mm bore of pipes.
Same as item 21-53, but 150 mm bore of pipes. Each 21-54 124
Same as item 21-53, but 230 mm bore of pipes. Each 21-55 186
Taking up carefully, cleaning gulley traps, disconnecting traps Each 21-56 124
etc., jointed in CM and stacking within 30M (only traps etc.)
fit for subsequent reuse, 100mm bore of pipes.

Same as item 21-56, but 150 mm bore of pipes. Each 21-57 186
Same as item 21-56, but 230 mm bore of pipes. Each 21-58 278
Sludge Pumps
Pumping set, submersible, Sewerage type, with AC electric Each 21-59 228300
motor 400V, 3phase, 50 cycles, capacity 14 cum / hour, head
30ft/9.14M, supply and fixing.
Same as item 21-59, but discharge 15 cum / hour, head Each 21-60 422177
60ft/18.30M.
Same as item 21-59, but discharge 16 cum / hour, head Each 21-61 767484
100ft/30M.
Same as item 21-59 to 21-61, but fixing only. Each 21-62 1155
Same as item 21-59 to 21-62, if removal only. Each 21-63 866

Description Unit SI No. Rate (Rs)


Slabs
Providing and laying, Pre-cast, RCC slab, length 0.914 M to Sqm 22-1 1828
1.398 M and width 0.457 M, including hoisting, setting and
jointing in CM (1:4), all as specified.
Same as item 22-1, but length exceeding 1.398 M and not Sqm 22-2 2296
exceeding 1.981 M, width 0.457 M.
Same as item 22-1, but length 0.914 M to 1.398 M, width Sqm 22-3 1885
0.304 M.
Same as item 22-1, but length 1.524 M to 1.981 M, width Sqm 22-4 2486
0.304 M.
Girders
Providing and laying, Pre-cast pre-stressed, R.C.C girders size Metre 22-5 1304
102 mm x 228 mm, including setting and hoisting, all as
specified for span 2.438 M to 4.877 M.
Same as item 22-5, but size 114 x 280 mm (for span 5.182 M Metre 22-6 1886
to 6.172 M).
Same as item 22-5, but size 127 x 337 mm (for span 5.182 M Metre 22-7 2231
to 6.782 M).
Same as item 22-5, but size 127 x 356 mm (for span 5.486 M Metre 22-8 2423
to7.391 M).
Same as item 22-5, but size 152 x 368 mm (for span 6.096 M Metre 22-9 2519
to 8.306 M).
Same as item 22-5, but size 178 x 457mm (for span 7.315 M Metre 22-10 3720
to 10.058 M).
Same as item 22-5, but size 203 x 483 mm (for span 8.534 M Metre 22-11 4252
to11.278 M).
Same as item 22-5, but size 203 x 508 mm (for span 9.754 M Metre 22-12 5408
to 12.69 M).
Same as item 22-5, but size 203 x 610 mm (for span 5.182 M Metre 22-13 5908
to 9.449 M).
Same as item 22-5 but size 203 x 686 mm (for span 5.486 M Metre 22-14 6738
to 10.973 M).
Same as item 22-5 but size 203 x 762 mm (for span 5.791 M Metre 22-15 7314
to 11.582 M).
Double Tees
Providing and laying, precast pre-stressed, RCC, Double Tee, Sqm 22-16 5236
size 3.048 M x 0.712 M, RCC roof panel (having web size
101mm x 171mm and slab thickness 51mm), for span from
9.754 M to 12.802 M including hoisting, complete, all as
specified.
Same as item 22-16, but for span from 13.410 M to 15.240 Sqm 22-17 5586
M.
Same as item 22-16, but for span from 15.850 M to 17.678 Sqm 22-18 5984
M.
Same as item 22-16, but for span from 18.288 M to 18.898 Sqm 22-19 7006
M.
Same as item 22-16 but for span from 19.507 M to 21.336 M. Sqm 22-20 6637

Providing and laying, pre-cast pre-stressed, RCC, Double Tee, Sqm 22-21 5152
size 1.524 M x 0.406 M, RCC roof panel (having web size
64mm x114mm and slab thickness 35 mm) span from 6.096
M to 7.925 M, including hoisting, complete, all as specified.

Same as item 22-21, but for span from 8.534 M to 9.754 M. Sqm 22-22 5152

Same as item 22-21 but for span from 10.363 M to 10.973 M. Sqm 22-23 5293

Same as item 22-21 but for span from 11.582 M to 12.192 M. Sqm 22-24 5433

Inverted Tee Beams


Providing and laying, pre-cast pre-stressed, RCC, Inverted Tee Metre 22-25 19167
beam, size 0.305 M x 0.699 M x 0.254. For Double Tee, size
1.524 M x 0.406 M, for span from 3.658 M to 6.096 M,
including hoisting, complete, all as specified.
Same as item 22-25, but for span from 6.401 M to 8.534 M. Metre 22-26 19448

Providing and laying, pre-cast pre-stressed, RCC, Inverted Tee Metre 22-27 18254
beam, size 0.305 M x 0.406 M x 0.254 M. For Double Tee
size, 1.524 M x 0.406 M, for span from 3.658 M to 6.096 M,
including hoisting, complete, all as specified.

Same as item 22-27, but for span from 6.401M to 8.534M. Metre 22-28 18815

‘L’ Beams
Providing and laying, pre-cast pre-stressed, RCC, L beam, size Metre 22-29 17332
0.305 M x 0.686 M x 0.254M. For Double Tee, size 3.048 M x
0.686M, for span from 3.658 M to 6.096 M, including
hoisting, complete, all as specified.
Same as item 22-29, but for span from 6.401 M to 8.534 M. Metre 22-30 17613

Providing and laying, pre-cast, pre-stressed, RCC, 'L' beam Metre 22-31 15829
size 0.305 M x 0.406 M x 0.254 M. For Double Tee, size 1.524
M x 0.406 M, for span from 3.658 M to 6.096 M, including
hoisting, complete, all as specified.
Same as item 22-31, but for span from 6.401 M to 8.534 M. Metre 22-32 16110

Boundary Wall
Providing and laying, pre-cast pre-stressed, RCC, "H" Section Metre 22-33 828
boundary wall, column size 102 mm x 229 mm, length 2.438
M to 3.658 M, complete, all as specified.

Same as item 22-33 but , column size 140 mm x 203 mm. Metre 22-34 1462

Providing and laying, pre-cast RCC boundary wall, coloured Metre 22-35 420
strip, 76 mm wide and 64 mm thick, all as specified.

Providing and laying, RCC pre-cast boundary wall column Each 22-36 472
caps, all as specified.
Steel ‘K’-Span
Supply and fix, Pre-Painted Galvanized Iron (PPGI) steel Sqm 22-37 1603
sheets for Steel 'K - Span from 6.096 M to 7.620 M using 0.5
mm, thick sheet @ 4.166 kg/sqm, complete, all as specified.

Same as item 22-37, but for span from 7.925 M to 9.144 M, Sqm 22-38 1887
using 0.6 mm thick sheet @ 4.941 kg/sqm
Same as item 22-37, but for span from 9.449 M to 10.668 M, Sqm 22-39 2148
using 0.7 mm thick sheet @ 5.705 kg/sqm.
Same as item 22-37, but for span from 10.973 M to 12.192 M Sqm 22-40 2416
using 0.8 mm thick sheet @ 6.480 kg/sqm.
Same as item 22-37, but for span from 12.497 M to 19.812 Sqm 22-41 2675
M, using 0.9 mm thick sheet @ 7.244kg/sqm.
Same as item 22-37, but for span from 20.117 M to 22.860 Sqm 22-42 2952
M, using 1.00 mm thick sheet @ 8.019kg/sqm.
Same as item 22-37, but for span from 22.860M to 25.908 M, Sqm 22-43 3457
using 1.2 mm thick sheet @ 9.548kg/sqm.
Same as item no. 22-37, but for span from 26.213 M to Sqm 22-44 3701
32.004 M using 1.3 mm thick sheet @ 10.323kg /sqm

Add to item 22-01 to 22-32, for hoisting for each subsequent Kg 22-45 4
4M or part thereof.
Add to item 22-37 to 22-44, for hoisting for each subsequent Kg 22-46 44
4M or part thereof.
Add to item 22-37 to 24-44, for transportation, for each Kg 22-47 44
subsequent 100 km or part thereof.
Providing and erecting Precast Hollow core slab size 1.292 M Sqm 22-48 4976
x 0.2 M for span 5.79 M to 6.4 M including hoisting, setting
and jointing in CM (1:4) all as specified.

Same as item 22-48 but for span 7.01 M to 8.23 M. Sqm 22-49 6258
Same as item 22-48 but for size 1.2192 M x 0.265 M for span Sqm 22-50 5675
7.01 M to 8.23 M, all as specified.
Same as item 22-50 but for span 8053 M to 9.75 M. Sqm 22-51 6661
Supply and fixing, fabrication and errection of LGS structure Sqm 22-52
upto required height and floor area as per user requirements
/ manufactures specifications, (Rate will be decided after
design / specifications).

Description Unit SI No. Rate (Rs)


Concrete
Demolition of Plain Cement Concrete. Cum 23-1 2174
Demolition of Premix Carpet / Bituminous Pavements. Cum 23-2 2254
Add to item 23-1 and 23-2, if dismantled in portions. Cum 23-3 225
Demolition of RCC floor or beams / roof slabs etc., separating Cum 23-4 2429
reinforcement from concrete, cleaning and straightening the
same.
Same as item 23-4 but when reinforcement is not required to Cum 23-5 2254
be separated from concrete.
Walls, Foundations
Demolition of walls, built in brick work, or Concrete blocks, or Cum 23-6 957
in stone masonry, built in any CM, including pillars, lintels,
struts etc.
Add to item 23-6, if dismantled in portions. Cum 23-7 225
Mud on Roofs
Removing mud from roofs, including plastering and leaping, if Cum 23-8 226
any.
Take up, Stone or Pre-cast concrete slab, floors, of any Cum 23-9 882
thickness, laid in any mortar.
Add to item 23-9, if dismantled in portions. Cum 23-10 38
Cutting Openings
Cutting through walls etc, for doors, windows or other Cum 23-11 3312
opening, or enlarging existing openings and form reveals, as
specified, in burnt brick work, Stone masonry or Concrete
block laid in any mortar.
Same as item 23-11, but RCC, including cutting Cum 23-12 4278
reinforcement.
Cutting small openings, for pipes etc., where surface area Cum 23-13 2326
does not exceeding 900 sq cm, and make good around the
same, in Burnt brick work, Stone masonry or Concrete blocks
in any mortar.
Same as item 23-13, but in RCC including cutting Cum 23-14 4430
reinforcement.
Wood Work
Cut out and demolish timber in scantling, in any position, not Cum 23-15 2640
elsewhere provided for, clear out nails etc., remove and stack
at site.
Cut out and demolish timber boarding, including flooring or Sqm 23-16 79
other position, not elsewhere provided, and stack on site

Cut out and demolish ballies, any dia. Metre 23-17 26


Iron and Steel Work
Take down CI, Iron or AC flue (or smoke) pipes, eaves, Metre 23-18 83
gutters, rain water pipes, valley gutters or flashing ridges and
hips including bends, swan necks, shoes etc., and any
supports or brackets, there to, (gutters, flashing ridges and
hips to be measured in this item only when not taken down
as part of roofing).
Dismantle Steel or Iron work of any description, and in any Kg 23-19 14
position, not elsewhere provided for.
Any position, not elsewhere provided for, dismantle to Sqm 23-20 50
remove, iron or steel sheeting in hearths covering to doors,
frames, curbs, mangers and similar fittings any description or
gauge.
Roof
Dismantle, AC corrugated sheets or corrugated iron plain Sqm 23-21 54
sheeting to walls, ceilings etc., including any ridges, hips,
valleys, wind ties, barge and eaves boarding (net area of roof
and or walls measured).
Miscellaneous
Dismantling single tiling of brick or PCC in roof or floor, laid in Sqm 23-22 120
CM, including half bricks or blocks on edge, in any portion.
Same as item 23-22, but of any other description including Sqm 23-23 180
ridges, hips or valleys (net area of roof surface measured, no
additional allowance for ridges, hips and valleys).

Dismantle double tiling of brick or PCC in roof laid in CM, Sqm 23-24 216
including half bricks or blocks on edge, in any position.

Same as item 23-24, but of any other description, including Sqm 23-25 324
ridges, hips and valleys (net surface of roof area measured).

Finishing
Taking up or down, tiles / Marble / granite work of any type Sqm 23-26 180
laid in floors / walls etc.
Plumbing and Drains
Take down sheet lead in flats, gutters, dormers, flashing, Kg 23-27 4
ridges, hips cisterns, etc. and similar work (not to be paid
when gutters, ridges and hips are taken down as part of
roofing).

Description Unit SI No. Rate (Rs)


Wiring
One fan point or one light point or one bell point, controlled Point 24-1 2289
by one switch, wiring complete with PVC, single core cable 1
2
mm , with PVC Channel patty, supply and fixing.

Same as item 24- 1 but 1.5 mm2 Point 24-2 2464


Same as item 24-1 or 24-2 but, fixing only. Point 24-3 690
Add to item 24-1, 24-2, or 24-3, if removal only. Point 24-4 173
One fan point or one light point or one bell point, controlled Point 24-5 3883
by one switch, wiring complete, with PVC single core cable 1
mm², in Surface conduit, stove enamelled, supply and fixing.

Same as item 24-5, but in Surface Flame proof conduit. Point 24-6 5270
Same as item 24-5, but in Concealed PVC conduit. Point 24-7 1627
Same as item 24-5, but in Surface PVC conduit. Point 24-8 2005
One fan point or one light point or one bell point, controlled Point 24-9 4058
by one switch, wiring complete, with PVC single core cable
1.5 mm², in Surface conduit, stove enamelled, supply and
fixing.
Same as item 24-9, but in Surface flame proof conduit. Point 24-10 5445
Same as item 24-9, but in Concealed PVC conduit. Point 24-11 1802
Same as item 24-9, but in Surface PVC conduit. Point 24-12 2180
Same as item 24-5 or 24-9, but fixing only. Point 24-13 1035
Same as item 24-6 or 24-10, but fixing only. Point 24-14 1035
Same as item 24-7 or 24-11, but fixing only. Point 24-15 375
Same as item 24-8 or 24-12, but fixing only. Point 24-16 690
Add to item 24-5, 24-9 or 24-13, if removal only. Point 24-17 345
Add to item 24-6, 24-10 or 24-14, if removal only. Point 24-18 345
Add to item 24-7, 24-11 or 24-15, if removal only. Point 24-19 289
Add to item 24-8, 24-12 or 24-16, if removal only. Point 24-20 345
One fan point or one light point or one bell point controlled Point 24-21 447
by one switch, wiring complete with PVC single/ core cable 1
mm2, but without PVC channel patty supply and fixing.

Same as item 24-21, but 1.5 mm2 Point 24-22 622


Same as item 24-21, 24-22, but fixing only. Point 24-23 173
Add to item 24-21, 24-22 or 24-23, if removal only. Point 24-24 173
One fan point or one light point or one bell point controlled Point 24-25 619
by one switch, wiring complete with PVC single core cable 1
mm², in surface or concealed conduit, but without conduit,
supply and fixing.
Same as item 24-25, but fixing only. Point 24-26 345
Add to item 24-25, or 24-26, if removal only. Point 24-27 150
One fan point or one light point or one bell point controlled Point 24-28 794
by one switch, wiring complete with PVC single core cable 1.5
mm,² in Concealed or surfaced conduit, stove enamelled, but
without conduit, supply and fixing.

Same as item 24-28, but fixing only. Point 24-29 345


Add to item 24-28 to 24-29, if removal only Point 24-30 173
Add for each additional light point on same switch circuit/ Point 24-31 1076
additional circuit, controlled by more than one switch, wiring,
2
complete with PVC single core cable 1 mm , with PVC
Channel patty , supply and fixing.
2 Point 24-32 1251
Same as item 24-31, but 1.5 mm
Same as item 24-31, 24-32 but fixing only. Point 24-33 518
Add to item 24-31, 24-32 or 24-33, if removal only Point 24-34 173
Add for each additional light point , one bell point on same Point 24-35 1035
switch circuit/ additional circuit, controlled by more than one
push switch, wiring complete with PVC single core cable 1
mm,² in Surface conduit, stove enamelled, supply and fixing.

Same as item 24-35, but in Surface Flame proof conduit. Point 24-36 1429

Same as item 24-35, but in concealed PVC conduit. Point 24-37 747
Same as item 24-35, but in surface PVC conduit. Point 24-38 758
Add for each additional light point, bell point on same switch Point 24-39 1210
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1.5 mm²
in Surface conduit, stove enamelled, supply and fixing.
Same as item 24-39, but in Surface Flame proof conduit. Point 24-40 1604

Same as item 24-39, but in Concealed PVC conduit. Point 24-41 922
Same as item 24-39, but in Surface PVC conduit. Point 24-42 933
Same as item 24-35 or 24-39, but fixing only Point 24-43 259
Same as item 24-36 or 24-40, but fixing only Point 24-44 345
Same as item 24-37 or 24-41, but fixing only Point 24-45 345
Same as item 24-38 or 24-42, but fixing only. Point 24-46 345
Add to item 24-35, 24-39 or 24-43, if removal only. Point 24-47 129
Add to item 24-36, 24-40 or 24-44, if removal only. Point 24-48 173
Add to item 24-37, 24-41 or 24-45, if removal only. Point 24-49 173
Add to item 24-38, 24-42 or 24-46, if removal only. Point 24-50 173
Add for each additional light point, bell point on same switch Point 24-51 447
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1 mm2 ,
but without PVC Channel patty, supply and fixing.

Same as item 24-51, but 1.5 mm2 Point 24-52 622


Same as item 24-51, 24-52 but fixing only Point 24-53 173
Add to item 24-51, 24-52 or 24-53 if removal only Point 24-54 115
Add for each additional light point, bell point on same switch Point 24-55 533
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1 mm² in
Surface conduit, stove enamelled but without conduit, supply
and fixing.
Same as item 24-55, but in Surface Flame proof conduit. Point 24-56 533

Same as item 24-55, but in concealed PVC conduit. Point 24-57 533
Same as item 24-55, but in surface PVC conduit Point 24-58 533
Add for each additional light point, bell point on same switch Point 24-59 708
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1.5 mm,²
in Surface conduit, stove enamelled, but without conduit,
supply and fixing
Same as item 24-59, but in Surface, Flame proof conduit. Point 24-60 708

Same as item 24-59, but in Concealed PVC conduit. Point 24-61 708
Same as item 24-59, but in Surface PVC conduit. Point 24-62 708
Same as item 24-55 to 24-62, but fixing only. Point 24-63 259
Add to item 24-55 to 24-62 or 24-63, if removal only. Point 24-64 86
One light point, controlled by two ways switch, wiring Point 24-65 2314
2
complete with PVC single core cable 1 mm , on PVC Channel
patty, supply and fixing
Same as item 24-65, but 1.5 mm2 Point 24-66 2524
Same as item 24-65, 24-66 but fixing only. Point 24-67 1484
Add to item 24-65, 24-66 or 24-67, if removal only. Point 24-68 682
One light point controlled by two way switch, wiring Point 24-69 3353
complete with PVC single core cable 1 mm2 in Surface
conduit stove enamelled, supply and fixing.
Same as item 24-69, but in Surface Flame proof conduit. Point 24-70 4740

Same as item 24-69, but in Concealed PVC conduit. Point 24-71 1247
Same as item 24-69, but in Surface PVC conduit. Point 24-72 1593
One light point controlled by two way switch, wiring Point 24-73 3563
complete with PVC single core cable 1.5 mm² Surface
conduits, stove enamelled, supply and fixing.
Same as item 24-73, but in Surface Flame proof conduit. Point 24-74 4951

Same as item 24-73, but in Concealed PVC conduit. Point 24-75 1457
Same as item 24-73, but in Surface PVC conduit. Point 24-76 1803
Same as item 24-69, or 24-73, but fixing only. Point 24-77 1035
Same as item 24-70, or 24-74, but fixing only. Point 24-78 1035
Same as item 24-71, or 24-75, but fixing only. Point 24-79 375
Same as item 24-72 or 24-76, but fixing only. Point 24-80 690
Add to item 24-69, 24-73 or 24-77, if removal only. Point 24-81 345
Add to item 24-70, 24-74 or 24-78, if removal only. Point 24-82 345
Add to item 24-71, 24-75 or 24-79, if removal only. Point 24-83 465
Add to item 24-72, 24-76 or 24-80, if removal only. Point 24-84 345
One light point, controlled by two way switch, wiring, Point 24-85 674
complete, with PVC single core cable 1 mm2, but without
PVC Channel patty, supply and fixing
Same as item 24-85 but1.5 mm2 Point 24-86 884
Same as item 24-85, 24-86 but fixing only. Point 24-87 345
Add to item 24-85, 24-86 or 24-87 if removal only. Point 24-88 173
One light point controlled by two-way switch, wiring Point 24-89 674
complete with PVC single core cable 1 mm² in Concealed or
surface conduit but without conduit, supply and fixing.

One light point controlled by two way switch, wiring Point 24-90 794
complete with PVC single core cable 1.5 mm² in Concealed or
surface conduit, but without conduit, supply and fixing.

Same as item 24-89, 24-90 but fixing only. Point 24-91 345
Add to item 24-89, 24-90 or 24-91, if removal only. Point 24-92 173
Add for each additional light point on same switch circuit, Point 24-93 1555
wiring complete with PVC single core cable 1 mm2, with PVC
Channel patty, supply and fixing.
Same as item 24-93, but 1.5 mm2 24-94 1730
Same as item 24-93, 24-94 but fixing only. Point 24-95 690
Add to item 24-93, 24-94 or 24-95, if removal only Point 24-96 345
Add for each additional light point on same switch two way Point 24-97 1232
circuit, wiring complete with PVC single core cable 1 mm² in
Surface conduit, stove enamelled, supply and fixing.

Same as item 24-97, but in Surface flame proof conduit. Point 24-98 1804

Same as item 24-97, but in Concealed PVC conduit. Point 24-99 830
Same as item 24-97, but in Surface, PVC conduit. Point 24-100 811
Add for each additional light point on same switch 2 way Point 24-101 1517
circuit, wiring complete with PVC single core cable 1.5 mm² in
Surface conduit , stove enamelled, supply and fixing.

Same as item 24-101, but in Flame proof conduit. Point 24-102 1979
Same as item 24-101, but in Concealed PVC conduit. Point 24-103 1005
Same as item 24-101, but in Surface PVC conduit. Point 24-104 986
Same as item 24-97 or 24-101, but fixing only. Point 24-105 345
Same as item 24-98 or 24-102, but fixing only. Point 24-106 345
Same as item 24-99 or 24-103, but fixing only. Point 24-107 375
Same as item 24-100 or 24-104, but fixing only. Point 24-108 345
Add to item 24-97, 24-101 or 24-105, if removal only. Point 24-109 173
Add to item 24-98, 24-102 or 24-106, if removal only. Point 24-110 173
Add to item 24-99, 24-103 or 24-107, if removal only. Point 24-111 173
Add to item 24-100, 24-104 or 24-108, if removal only. Point 24-112 173

Add for each additional light point on same switch 2 way Point 24-113 674
2
circuit, wiring complete with PVC single core cable 1 mm ,
but without PVC Channel patty, supply and fixing.

Same as item 24-113, but1.5 mm2 Point 24-114 794


Same as item 24-113, 24-114 but fixing only. Point 24-115 345
Add to item 24-113, 24-114 or 24-115, if removal only Point 24-116 173
Add for each additional light point on same switch 2-way Point 24-117 619
circuit, wiring complete with PVC single core cable 1 mm², in
Surface conduit stove enamelled, but without conduit, supply
and fixing.
Same as item 24-117, but in Surface Flame proof conduit. Point 24-118 619

Same as item 24-117, but in Concealed PVC conduit. Point 24-119 619
Same as item 24-117, but in Surface PVC conduit. Point 24-120 619
Add for each additional light point on Same switch 2-way Point 24-121 794
circuit, wiring complete with PVC single core cable 1.5 mm² in
Surface conduit, stove enamelled but without conduit, supply
and fixing.
Same as item 24-121, but in Surface Flame proof conduit. Point 24-122 794

Same as item 24-121, but in Concealed PVC conduit. Point 24-123 794
Same as item 24-121, but in Surface PVC conduit. Point 24-124 794
Same as item 24-117 to 24-124, but fixing only. Point 24-125 345
Add to item 24-117 to 24-124, or 24-125 if removal only. Point 24-126 173

One three pin socket outlet, 5 A, point controlled by one Point 24-127 2232
switch, wiring complete with PVC single core Cable 1 mm2 ,
with PVC Channel patty, including earth wire, supply and
fixing.
Same as item 24-129, but 1.5 mm2 Point 24-128 2407
Same as item 24-129, 24-130 but fixing only. Point 24-129 1035
Add to item 24-129, 24-130 or 24-131, if removal only Point 24-130 173
One three pin socket outlet, 5A, point controlled by one Point 24-131 3564
switch, wiring complete with PVC single core cable 1 mm², in
Surface conduit, enamelled including earth wire, supply and
fixing.
Same as item 24-131, but in Surface flame proof conduit. Point 24-132 4477

Same as item 24-131, but in Concealed PVC conduit. Point 24-133 2265
Same as item 24-131, but in Surface PVC conduit. Point 24-134 2112
One three pin socket outlet, 5 A, point controlled by one Point 24-135 3740
switch, wiring complete PVC with single core cable 1.5 mm²
in Surface conduit, stove enamelled, including earth wire,
supply and fixing.
Same as item 24-135, but in Surface Flame proof conduit. Point 24-136 4652

Same as item 24-135, but in Concealed PVC conduit. Point 24-137 2440
Same as item 24-135, but in Surface PVC conduit. Point 24-138 2287
One three pin socket outlet, 5 A, point controlled by one Point 24-139 792
switch, wiring complete with PVC single core cable, 1 mm2 ,
including earth wire, on PVC Channel patty, but without PVC
Channel patty, supply and fixing.
Same as item 24-139, but 1.5 mm2 Point 24-140 967
Same as item 24-139, 24-140 but fixing only. Point 24-141 518
Add to item 24-139, 24-140 or 24-141, if removal only Point 24-142 173
One three pin socket outlet, 5 A, point controlled by one Point 24-143 620
switch, wiring complete with PVC single core cable 1 mm², in
Concealed or Surface conduit, but without conduit and earth
wire, supply and fixing.
Same as item 24-143, but fixing only. Point 24-144 345
Add to item 24-143, or 24-144, if removal only. Point 24-145 173
One three pin socket outlet, 5 A, point controlled by one Point 24-146 794
switch, wiring complete with PVC single core cable 1.5 mm²,
in Concealed or Surface conduit but without conduit and
earth wire, supply and fixing.
Same as item 24-146 but fixing only. Point 24-147 345
Add to item 24-146 or 24-147, if removal only Point 24-148 173
One three pin socket outlet, 15 A, point controlled by one Point 24-149 2708
switch, wiring complete with PVC single core cable 2.5 mm2 ,
on PVC Channel Patty, including earth wire, supply and fixing.

Same as item 24-149, but fixing only. Point 24-150 1035


Add to item 24-149 or 24-150, if removal only. Point 24-151 690
One three pin socket outlet, 15 A, point controlled by one Point 24-152 3921
switch, wiring complete with PVC single core cable 2.5 mm²,
in Surface conduit stove enamelled, including earth wire,
supply and fixing.
Same as item 24-152, but in Surface Flame proof conduit. Point 24-153 4541

Same as item 24-152, but in Concealed PVC conduit. Point 24-154 3127
Same as item 24-152, but in Surface PVC conduit. Point 24-155 3054
Same as item 24-131, 24-135 or 24-152, but fixing only. Point 24-156 1035

Same as item 24-132, 24-136 or 24-153, but fixing only. Point 24-157 1500

Same as item 24-133, 24-137 or 24-154 but fixing only. Point 24-158 1725

Same as item 24-134, 24-138 or 24-155, but fixing only. Point 24-159 1035

Add to item 24-131, 24-135, 24-152 or 24-156, if removal Point 24-160 690
only.
Add to item 24-132, 24-136, 24-153 or 24-157, if removal Point 24-161 690
only.
Add to item 24-133, 24-137, 24-154 or 24-158, if removal Point 24-162 690
only.
Add to item 24-134, 24-138, 24-155 or 24-159, if removal Point 24-163 690
only.
One three pin socket outlet, 15 A, point controlled by one Point 24-164 1279
switch, wiring complete with PVC single core cable 2.5 mm2 ,
but without PVC Channel Patty and earth wire,, supply and
fixing.
Same as item 24-164, but fixing only. Point 24-165 517
Add to item 24-164 or 24-165, if removal only. Point 24-166 172
One three pin socket outlet, 15 A, point controlled by one Point 24-167 1279
switch, wiring complete with PVC single core cable 2.5 mm²
copper conductor in Concealed or Surface conduit but
without conduit, and earth wire, supply and fixing.

Same as item 24-167, but fixing only. Point 24-168 690


Add to item 24-167 or 24-168, if removal only Point 24-169 345
Copper conductor 14 SWG for 3 pin 5 A, or 3 pin, 15 A, socket Point 24-170 364
outlet points, in Concealed or Surface conduit, but without
conduit, supply and fixing.
Same as item 24-170, but fixing only. Point 24-171 86
Add to item 24-170 or 24-171, if removal only. Point 24-172 43
Cable unsheathed for earth continuity conductor, 1 mm² Point 24-173 180
used for light/ fan/ bell 5A socket outlet points, where
metallic boards/ housings, in Concealed or Surface conduit,
but without conduit, supply and fixing.

Same as item 24-173, but fixing only. Point 24-174 86


Add to item 24-173 or 24-174, if removal only. Point 24-175 43
Cable for earth continuity conductor 1.5 mm² used for 15 A Point 24-176 266
socket outlet points, where metallic boards/housings are
used, in Concealed or Surface conduit, but without conduit,
supply and fixing.
Same as item 24-176, but fixing only. Point 24-177 86
Add to item 24-176 or 24-177, if removal only Point 24-178 43
Fittings and Accessories For Pendants
Pendant, ordinary, comprising ceiling rose, lamp holder Each 24-179 370
Bakelite, BC, CG, with shade carrier ring and twin core 0.75
mm2 flexible cord upto 3 M in length, supply and fixing.

Same as item 24-179, but without lamp holder Each 24-180 318
Same as item 24-179, but fixing only. Each 24-181 86
Same as item 24-180, but fixing only. Each 24-182 76
Same as item 24-179 to 24-182, if removal only. Each 24-183 52
Lamp Holder
Lamp holder, batten BC, with shade carrier ring, 20 mm, all Each 24-184 87
insulated reinforced linear, supply and fixing.
Same as item 24-184, but 45° angle Each 24-185 87
Lamp holder ES, CG, supply and fixing Each 24-186 87
Lamp holder ES, threaded 20 mm dia, ET, supply and fixing. Each 24-187 102

Lamp holder brass screw type for 500/300W Lamp, supply Each 24-188 184
and fixing
Same as item 24-184 to 24-188, but fixing only. Each 24-189 61
Add to item 24-184 to 24-188, or 24-189 if removal only. Each 24-190 30

LED Lights
LED strip light 2 feet, 18 watt 220/240 volts for wall or ceiling Each 24-191 786
mounted approved type Standard, Supply and fixing.

Same as item 24-191 but Deluxe Each 24-192 1158


Same as item 24-191 but Premium Each 24-193 2610
LED strips light 4 feet, 36 watt 220/240 volts for wall or Each 24-194 1482
ceiling mounted approved type Standard, Supply and fixing.

Same as item 24-194 but Deluxe Each 24-195 1998


Same as item 24-194 but Premium Each 24-196 3918
Same as item 24-191 to 24-196, but fixing only. Each 24-197 138
Add to item 24-191, 24-196 or 24-197, if removal only. Each 24-198 104

LED Recessed panel light, 6 watts 220/240 volts, round or Each 24-199 735
Square approved type Standard Supply and fixing.
Same as item 24-199 but Deluxe. Each 24-200 1005
Same as item 24-199 but Premium. Each 24-201 1289
LED Recessed panel light, 12 watts 220/240 volts, round or Each 24-202 1071
Square, approved type, Standard, Supply and fixing.

Same as item 24-202 but Deluxe. Each 24-203 1395


Same as item 24-202 but Premium. Each 24-204 1779
LED Recessed panel light 18 watts, 220/240 volts, round or Each 24-205 1341
Square, approved type, Standard Supply and fixing.

Same as item 24-205 but Deluxe. Each 24-206 1865


Same as item 24-205 but Premium. Each 24-207 2295
LED Recessed panel light 24 watts, 220/240 volts, round or Each 24-208 2025
Square, approved type, Standard Supply and fixing.

Same as item 24-208 but Deluxe. Each 24-209 2073


Same as item 24-208 but Premium. Each 24-210 4021
Same as item 24-199 to 24-210, but fixing only. Each 24-211 345
Add to item 24-199 to 24-210 or 24-211, if removal only. Each 24-212 173

LED Surface Mounted panel light, 6 watts 220/240 volts, Each 24-213 657
round or Square, approved type Standard, Supply and fixing

Same as item 24-213 but Deluxe. Each 24-214 873


Same as item 24-213 but Premium. Each 24-215 1436
LED Surface Mounted panel light, 12 watts 220/240 volts, Each 24-216 1099
round or Square, approved type Standard, Supply and fixing

Same as item 24-216 but Deluxe. Each 24-217 1395


Same as item 24-216 but Premium. Each 24-218 1863
LED Surface Mounted panel light, 18 watts 220/240 volts, Each 24-219 1375
round or Square complete, approved type Standard, Supply
and fixing
Same as item 24-219 but Deluxe. Each 24-220 1395
Same as item 24-219 but Premium. Each 24-221 2235
LED Surface Mounted panel light, 24 watts 220/240 volts, Each 24-222 2205
round or Square, approved type Standard, Supply and fixing.

Same as item 24-222 but Deluxe. Each 24-223 3813


Same as item 24-222 but Premium. Each 24-224 4801
Same as item 24-213 to 24-224, but fixing only. Each 24-225 345
Add to item 24-213 to 24-224 or 24-225, if removal only. Each 24-226 173

LED Down light, 7 watts, 220/240 volts, approved type, Each 24-227 690
Standard, Supply and fixing.
Same as item 24-227 but Deluxe. Each 24-228 780
Same as item 24-227 but Premium. Each 24-229 840
LED Down light, 12 watts, 220/240 volts, approved type, Each 24-230 960
Standard Supply and fixing.
Same as item 24-230 but Deluxe Each 24-231 1146
Same as item 24-230 but Premium Each 24-232 1158
LED Down light, 18 watts, 220/240 volts, approved type, Each 24-233 1230
Standard. Supply and fixing.
Same as item 24-233 but Deluxe Each 24-234 1398
Same as item 24-233 but Premium Each 24-235 1758
Same as item 24-227 to 24-235, but fixing only. Each 24-236 259
Add to item 24-227 to 24-235 or 24-236, if removal only. Each 24-237 173

LED/SMD Bulb, 5 watts, 220/240 volts, approved type supply Each 24-238 203
and fixing
Same as item 24-238 but, 7 watts. Each 24-239 186
Same as item 24-238 but, 12 watts Each 24-240 207
Same as item 24-238 but, 18 watts Each 24-241 400
Same as item 24-238 but, 30 watts Each 24-242 609
Same as item 24-238 but, 50 watts Each 24-243 1175
Same as item 24-212 to 24-217, but fixing only. Each 24-244 35
Add to item 24-212 to 24-217 or 24-218, if removal only. Each 24-245 28

Switch SP, 5 A, Piano type single or two way mounted in cast Each 24-246 107
or malleable iron galvanize conduit box, with solid metal or
Bakelite plate, supply and fixing.
Same as item 24-246, but fixing only Each 24-247 76
Add to item 24-246 or 24-247, if removal only. Each 24-248 38
Switch water tight, SP, 5 A, galvanized, front side operated, Each 24-249 433
screwed, 20 mm, conduit terminal or through pattern, one
way, supply and fixing.
Same as item 24-249, but fixing only Each 24-250 121
Add to item 24-249 or 24-250, if removal only Each 24-251 61
Switch, SP, socket outlet 3 pin, 5 A, Universal/Multiple Each 24-252 183
Bakelite, shuttered pattern, complete, supply and fixing.

Same as item 24-252, but in galvanized, cast or malleable Each 24-253 378
iron, in lieu of Bakelite box
Same as item 24-252, 24-253, but fixing only. Each 24-254 121
Add to item 24-252, 24-253 or 24-254, if removal only. Each 24-255 61

Plug 3 pin, 5 A, supply and fixing. Each 24-256 71


Same as item 24-256, but 15 A Each 24-257 123
Same as item 24-256 or 24-257, but fixing only. Each 24-258 30
Add to item 24-256, 24-257 or 24-258, if removal only. Each 24-259 15

Switch, SP, socket out let 3 pin, 15 A, shuttered pattern, Each 24-260 271
mounted in Bakelite box complete, supply and fixing.

Switch, SP, Socket outlet, 3 pins, 20 A, shuttered pattern, Each 24-261 348
mounted in Bakelite box, complete, supply and fixing.

Switch, SP socket outlet 3 pin, 15 A, shuttered pattern, Each 24-262 511


mounted in a weather proof CI case, drilled and tapped 20
mm, ET with screw on type, metal cap attached by chain,
complete, supply and fixing.
Same as item 24-260 to 24-262 but fixing only Each 24-263 121
Add to item 24-260 to 24-262 or 24-263, if removal only. Each 24-264 61

Socket Outlet, Industrial 380/400 V, 3 phase, neutral and Each 24-265 1543
earth, water proof 16A, supply and fixing.
Same as item 24-265, but 32A. Each 24-266 1867
Same as item 24-265, but 63A. Each 24-267 5326
Same as item 24-265 to 24-267 but fixing only. Each 24-268 607
Add to item 24-265 to 24-267 or 24-268, if removal only. Each 24-269 304

Plug for Socket Outlet, Industrial 380/400 V, 3 phase, neutral Each 24-270 776
and earth, water proof, 16 A, supply and fixing.
Same as item 24-270, but 32 A Each 24-271 1124
Same as item 24-270, but 63 A Each 24-272 2975
Same as item 24-270 to 24-271, but fixing only. Each 24-273 182
Same as item 24-272, but fixing only Each 24-274 455
Add to item 24-270 to 24-271 or 24-273, if removal only. Each 24-275 91

Add to item 24-272 or 24-274 if removal only. Each 24-276 227


Bulk head Fittings
Bulk head fittings CI, without guard, tapped, 20 mm ET, Each 24-277 751
according to BSS, supply and fixing
Same as item 24-277, but with guard Each 24-278 818
Bulk head fitting plastic body without guard, tapped 20 mm Each 24-279 562
ET, according to BSS, complete approved type supply and
fixing.
Same as item 24-279 but with guard. Each 24-280 634
Same as item 24-277 to 24-280, but fixing only. Each 24-281 152
Add to item 24-277 to 24-280 or 24-281, if removal only. Each 24-282 76

Earthing
Earth, complete as described in Para 24.16 of the Each 24-283 5540
Specifications, with 8 SWG copper conductor, supply and
fixing.
Same as item 24-283, but with 6 SWG. Each 24-284 5989
Same as item 24-283, but with 2 SWG. Each 24-285 7406
Same as item 24-283, but with 3/0 SWG. Each 24-286 9769
Same as item 24-283 to 24-286, but fixing only. Each 24-287 2199
Add to item 24-283 to 24-286 or 24-287, if removal only. Each 24-288 379

Lightning Conductor
Air termination for Lightning Conductor, with 15 mm dia Each 24-289 3381
copper rod, 150 cm long, with gunmetal copper base, 75 mm
x 40 mm x 30 mm, fixed complete, with brass bolts, supply
and fixing.
Same as item 24-289, but fixing only. Each 24-290 304
Add to item 24-289 or 24-290, if removal only. Each 24-291 152
Down conductor, roof conductor and conductor required for Metre 24-292 1020
bonding exposed metal work to earthing conductor with
copper strips, 25 mm x 3 mm, supply and fixing.

Same as item 24-292, but fixing only. Metre 24-293 121


Add to item 24-292 or 24-293, if removal only. Metre 24-294 61
Inspection joints, cross, tee, straight as per site requirement, Each 24-295 628
supply and fixing.
Same as item 24-295, but fixing only Each 24-296 76
Add to item 24-295 or 24-296, if removal only. Each 24-297 38
Earth for Lightning conductor, complete as described in Para Each 24-298 7310
24.19.6(2) of the Specifications, inclusive of copper strip upto
test joint, supply and fixing.
Same as item 24-298, but as described in Para 24.19.6(1) of Each 24-299 8414
the Specifications.
Same as item 24-298 or 24-299, but fixing only. Each 24-300 2350
Add to item 24-298, 24-299 or 24-300 if removal only. Each 24-301 607
Energy Meter
Analogue Electric Meter AC 220/250 V, single phase, 50 cycle Each 24-302 2659
upto 30 A, supply and fixing
Digital Electric Meter AC 220/250 V, single phase, 50 cycle Each 24-303 5153
upto
30 A, supply and fixing
Same as item 24-302, 24-303, but fixing only Each 24-304 380
Add to item 24-302, 24-303 or 24-304, if removal only. Each 24-305 190

Meter electric AC 400 volts, 3 phase, 50 cycle, 4 wire, 15-90 Each 24-306 10117
A, supply and fixing.
Same as item 24-306, but 100 A Each 24-307 10117
Same as item 24-306, but 200 A complete with CTs Each 24-308 23351
Digital Electric Meter (TOU) AC 400 volts, 3 phase, 50 cycle, 4 Each 24-309 19471
wire, 15-90 A, supply and fixing.
Same as item 24-309, but 100 A. Each 24-310 19471
Same as item 24-309 but 200 A, complete with CTs. Each 24-311 28991
Same as item 24-306, to 24-307 or 24-309 to 24-310, but Each 24-312 759
fixing only.
Same as item 24-308 or 24-311, but fixing only. Each 24-313 911
Add to item 24-306 to 24-313, if removal only. Each 24-314 380
Smart Meters
Supply and fixing of Static 3-Phase, whole current Smart Each 24-315 20111
energy meter DLMS/COSEM complaint (TOD/TOU) with built
in GSM/GPRS communication Module, Measuring the
parameters i.e active power KWH, reactive power KVARH,
Phase volts, Phase current, MDI, etc Power factor and
demand/schedual automatic meter reading i.e hourly, daily
weekly monthly, 440 volt, 3 Phase, four wire, 50HZ all as
specified.

Same as item 24-315, but single Phase 220/240 volts Each 24-316 10511
Same as item 24-315, 24-316 but fixing only Each 24-317 911
Add to item 24-315, 24-316 or 24-317, if removal only. Each 24-318 455

Flame Proof Fittings


Switch Flame proof, SP, 5 A, drilled and tapped on both sides, Each 24-319 1126
solid brass threaded plug for fitting the hole not required.
The switch and cover be completely inter-locked, supply and
fixing. (The complete unit should comply with BSS No.229,
542 and 889)
Switch socket flame proof, 3 pin 5 A, complete as specified, Each 24-320 6048
supply and fixing.
Same as item 24-319, but 15 A Each 24-321 9895
Flame proof Plug & Socket Outlet, industrial 380/400 V, 3 Each 24-322 31698
phase, neutral and earth, water protected 16A complete,
approved type supply and fixing.
Same as Item 24-322 but 32 A. Each 24-323 34559
Same as Item 24-322 but 63 A. Each 24-324 40110
Same as item 24-319 to 24-324, but fixing only. Each 24-325 152
Add to item 24-319 to 24-324 or 24-325, if removal only Each 24-326 76

Switch fuse Flame proof, SP, 250 V, 15 A, terminal chamber Each 24-327 6190
drilled and tapped, 25 mm ET on both sides, solid brass
threaded plug for sealing hole not required, supply and fixing
(The complete unit should comply with BSS No 229, 542 and
889).
Same as item 24-327, but 250/500 V, 30 A Each 24-328 7210
Same as item 24-327, but TPNL, 500 V, 15 A Each 24-329 10207
Same as item 24-327, but TPNL, 500 V, 30 A Each 24-330 17407
Same as item 24-327, but TPNL, 500 V, 60 A Each 24-331 25063
Same as item 24-327, but TPNL, 500 V, 100 A Each 24-332 36447
Same as item 24-327, but TPNL, 500 V, 200 A Each 24-333 62544
Same as item 24-327, but TPNL, 500 V, 300 A Each 24-334 79980
Same as item 24-327, but fixing only Each 24-335 190
Same as item 24-328, but fixing only Each 24-336 190
Same as item 24-329, but fixing only Each 24-337 607
Same as item 24-330, but fixing only Each 24-338 607
Same as item 24-331 or 24-332, but fixing only Each 24-339 1063
Same as item 24-333 or 24-334, but fixing only Each 24-340 1518
Add to item 24-327, 24-328, 24-335 or 24-336, if removal Each 24-341 95
only
Add to item 24-329, 24-330, 24-336 or 24-337, if removal Each 24-342 304
only
Add to item 24-331 to 24-332 or 24-338, if removal only Each 24-343 531

Add to item 24-333, 24-334 or 24-339, if removal only Each 24-344 759
Flame proof fitting, 20 mm ET tapped entry, CI body, grey Each 24-345 4203
painted, with heavy glass cemented to fixed ring, strong wire
guard and lamp holder with terminal chamber, internal
connections of solid metal passing through insulating sleeves
dispersive or angle type, vitreous enamelled reflector, over all
height 300 mm and overall dia 175 mm, suitable for 60/100
W lamp, supply and fixing.

Same as item 24-345, but rectangular, approved type, Each 24-346 7172
suitable to take upto 150W lamp.
Same as item 24-345 or 24-346, but fixing only. Each 24-347 152
Add to item 24-345, 24-346 or 24-347 if removal only. Each 24-348 76
Spare glass and ring for item 24-345 or 24-346, supply and Each 24-349 796
fixing.
Same as item 24-349, but fixing only. Each 24-350 76
Add to item 24-349 or 24-350, if removal only. Each 24-351 38
Switch Fuses

Change over switch, 15 A, SP, 250 V, 50 cycles, DP, wall Each 24-352 1052
mounted type, supply and fixing.
Same as item 24-352 but 30 A Each 24-353 1652
Change over switch, 30 A, TP with NL, wall mounted type, Each 24-354 3900
supply and fixing.
Same as item 24-354, but 60 A. Each 24-355 5594
Same as item 24-354, but 100 A. Each 24-356 8798
Same as item 24-354, but 200 A. Each 24-357 16361
Same as item 24-354, but 300 A. Each 24-358 18641
Same as item 24-354, but 400 A. Each 24-359 33813
Same as item 24-354, but 500 A. Each 24-360 42717
Same as item 24-352 to 24-355, but fixing only. Each 24-361 345
Same as item 24-356 to 24-358, but fixing only. Each 24-362 518
Same as item 24-359 to 24-360, but fixing only. Each 24-363 690
Add to item 24-352 to 24-355 or 24-360, if removal only. Each 24-364 259
Add to item 24-356 to 24-360 or 24-362, 24-363, if removal Each 24-365 455
only.
MCCBs SP
MCCB, SP, 6 to 63 A. (Breaking capacity 6 KA), supply and Each 24-366 540
fixing
Same as item 24-366 but double pole. Each 24-367 1383
Circuit breaker, built in plug type, 3 pin (Breaking capacity 6 Each 24-368 898
KA) 6 to 20 A, supply and fixing.
Same as item 24-366 to 24-368, but fixing only. Each 24-369 86
Add to item 24-366 to 24-368 or 24-369 if removal only. Each 24-370 57

MCCB 3 Pole
MCCB, 3 Pole 500/600 V, 50/60 cycles, complete with Each 24-371 4853
thermal and magnetic trips, 3 to 30 A, (breaking capacity 2.5
KA), supply and fixing.
Same as item 24-371, but 40 to 50 A. Each 24-372 5086
Same as item 24-371, but 15 to 60 A (breaking capacity 5 KA). Each 24-373 5213

Same as item 24-371, but 75 to 100 A (breaking capacity 5 Each 24-374 6078
KA).
Same as item 24-371, but 125 to 225 A (breaking capacity 18 Each 24-375 11958
KA).
Same as item 24-371, but 250 to 400 A (breaking capacity 25 Each 24-376 14167
KA).
Same as item 24-371, but 500 to 600 A (breaking capacity 25 Each 24-377 55118
KA)
Same as item 24-371, but 800 A with external handle Each 24-378 59970
(breaking capacity 45 KA).
Same as item 24-371, but 1000 A with external handle Each 24-379 164490
(breaking capacity 85 KA)
Same as item 24-371, but 1250 A with external handle Each 24-380 181290
(breaking capacity 85 KA)
Same as item 24-371, 24-372 or 24-373, but fixing only. Each 24-381 173

Same as item 24-374 or 24-375, but fixing only. Each 24-382 259
Same as item 24-376 or 24-377, but fixing only. Each 24-383 518
Same as item 24-378 to 24-380, but fixing only Each 24-384 690
Add to item 24-371 to 24-373 or 24-381, if removal only. Each 24-385 114

Add to item 24-374 to 24-375, or 24-382, if removal only. Each 24-386 171

Add to item 24-376 to 24-377 or 24-383, if removal only. Each 24-387 342

Add to item 24-378 to 24-380 or 24-384, if removal only. Each 24-388 342

MCCB 4 Pole
MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with Each 24-389 8378
thermal and magnetic trip 3 to 30 A (Breaking capacity 2.5
KV), supply and fixing.
Same as item 24-389 but 40 to 50 A. Each 24-390 8378
Same as item 24-389 but 60 to 100 A. Each 24-391 8378
Same as item 24-389 but 125 A. Each 24-392 10515
Same as item 24-389 but 160 to 250 A breaking capacity. Each 24-393 14618

Same as item 24-389 but 300 to 400 A (Breaking capacity 50 Each 24-394 36415
KA).
Same as item 24-389 but 500 to 630 A (Breaking capacity 50 Each 24-395 51800
KA).
Same as item 24-389 but 800 A with external handle Each 24-396 87869
(Breaking capacity 50 KA).
Same as item 24-396 but 1000 A (Breaking capacity 70 KA). Each 24-397 144280

Same as item 24-397 but 1250 A. Each 24-398 185305


Same as item 24-389 to 24-391 but fixing only. Each 24-399 173
Same as item 24-392 to 24-393 but fixing only. Each 24-400 259
Same as item 24-394 to 24-395 but fixing only. Each 24-401 518
Same as item 24-396 to 24-398 but fixing only. Each 24-402 690
Add to item 24-389 to 24-391 or 24-399 if removal only. Each 24-403 114

Add to item 24-392 to 24-393 or 24-400 if removal only. Each 24-404 171

Add to item 24-394 to 24-395 or 24-401 if removal only. Each 24-405 342

Add to item 24-396 to 24-398 or 24-402 if removal only. Each 24-406 449

Earth leakage circuit breakers, 4 pole, 500/660 V, 50/60 Each 24-407 37781
cycle, complete with earth leakage, over load and short
circuit protection, 15 to 100 A (breaking capacity 14 KA, at
415 V), supply and fixing.
Same as item 24-407, but 200 A (breaking capacity 35 KA). Each 24-408 62191

Same as item 24-407, but fixing only. Each 24-409 345


Same as item 24-408, but fixing only. Each 24-410 345
Add to item 24-407 or 24-409, if removal only. Each 24-411 121
Add to item 24-408 or 24-410, if removal only. Each 24-412 114
Bus Bar Chamber
Bus bar chamber, 600/610 mm long, steel sheet / CI with Each 24-413 11410
hinged cover, hard drawn copper bus bars mounted on well
insulated with micanite or other approved insulating material
frames, complete with main and branch cables, socket and
terminals, enamel paint inside and black outside, 500 V,
60/100 A, 4 bars, 400 mm height, 175-225 mm depth, supply
and fixing.

Same as item 24-413, but 500 V, 200 A. Each 24-414 12743


Same as item 24-413, but 500 V, 300 A. Each 24-415 13769
Same as item 24-413, but 500 V, 500 A. Each 24-416 16025
Same as item 24-413 to 24-416, but fixing only. Each 24-417 518
Add to item 24-413 to 24-416 or 24-417, if removal only. Each 24-418 342

Conduit
Conduit 20 mm dia, heavy gauge Class-"B", screwed, Metre 24-419 248
complete with bends, tees, boxes, saddles etc, stove
enamelled for Surface wiring, supply and fixing.
Same as item 24-419, but 25 mm dia. Metre 24-420 290
Same as item 24-419, but 40 mm dia. Metre 24-421 426
Same as item 24-419, but 50 mm dia. Metre 24-422 675
Same as item 24-419, or 24-420, but fixing only Metre 24-423 86
Same as item 24-421 or 24-422, but fixing only. Metre 24-424 104
Add to item 24-419, 24-420 or 24-423, if removal only. Metre 24-425 57

Add to item 24-421, 24-422 or 24-424, if removal only. Metre 24-426 68

Conduit 20 mm dia, heavy gauge Class "B" screwed complete Metre 24-427 523
with all bends, tees, boxes, saddles etc, stove enamelled for
Concealed wiring, supply and fixing.
Same as item 24-427, but 25 mm dia. Metre 24-428 565
Same as item 24-427, but 40 mm dia. Metre 24-429 695
Same as item 24-427, but 50 mm dia. Metre 24-430 943
Same as item 24-427 or 24-428, but fixing only. Metre 24-431 328
Same as item 24-429 or 24-430, but fixing only. Metre 24-432 328
Add to item 24-427, 24-428 or 24-431, if removal only. Metre 24-433 178

Add to item 24-429 to 24-430 or 24-432, if removal only. Metre 24-434 196

PVC conduit, 20 mm dia, complete with all bends, tees, Metre 24-435 134
boxes, saddles etc for Surface wiring, and concealed wiring,
supply and fixing.
Same as item 24-435, but 25 mm dia. Metre 24-436 154
Same as item 24-435, but 40 mm dia. Metre 24-437 270
Same as item 24-435, but 50 mm dia. Metre 24-438 357
Same as item 24-435 or 24-436, but fixing only Metre 24-439 72
Same as item 24-437 or 24-438, but fixing only. Metre 24-440 86
Add to item 24-435, 24-436 or 24-439, if removal only. Metre 24-441 45

Add to item 24-437, 24-438 or 24-440, if removal only. Metre 24-442 55

Add to Item 24-435 to 24-438 if grooving/cut is required Metre 24-443 298


including refilling and dressing of groves / cuts.

Conduit, 20 mm dia, heavy gauge Class-"B", screwed, solid Metre 24-444 456
drawn, complete with all bends, tees, boxes saddels etc.,
stove enamelled for surface wiring, supply and fixing (fittings
shall be flame proof and conform to BS No. 229 and 889).

Same as item 24-444, but 25 mm dia. Metre 24-445 548


Same as item 24-444, but 40 mm dia. Metre 24-446 770
Same as item 24-444, but 50 mm dia. Metre 24-447 1061
Same as item 24-444 to 24-447 but fixing only. Metre 24-448 86
Add to item 24-444 to 24-447 or 24-448, if removal only. Metre 24-449 55

Bell Push, 3A, 250 V, supply and fixing. Each 24-450 140
Same as item 24-450, but fixing only. Each 24-451 35
Add to item 24-450 or 24-451, if removal only. Each 24-452 21
Electric bell, AC/DC, Bakelite case, pressed iron frame, steel Each 24-453 326
contact spring and nickel plated, brass contact pillars both
having silver contact points round and nickel / CP steel gong,
supply and fixing.
Same as item 24-453, but fixing only. Each 24-454 52
Add to item 24-453 or 24-454, if removal only. Each 24-455 34
Buzzer, Bakelite case, suitable for operation on AC/DC, main Each 24-456 218
supply 100/110 V and 200/250 V, supply and fixing.

Same as item 24-456, but fixing only. Each 24-457 52


Add to item 24-456 or 24-457, if removal only. Each 24-458 34
Fan Works
Take down fan, clean externally, bearings, dust field coils, Each 24-459 568
armature, commutater, provide fresh clean lubricant (oil or
grease as required), adjust for sweep running, fix blades and
re-fix complete in position
Same as item 24-459, but fixing only. Each 24-460 518
Clamp hook for fan, ordinary type, supply and fixing. Each 24-461 254
Same as item 24-461, but box concealed or for girder. Each 24-462 259
Same as item 24-461 or 24-462, but fixing only. Each 24-463 86
Add to item 24-461, 24-462 or 24-463, if removal only. Each 24-464 55

Fan electric with copper winding, blades, canopy and rod Each 24-465 5247
including connection, provision of cable and ceiling rose, for
fan 140 cm and 120 cm sweep, without regulator “Standard”,
supply and fixing.
Same as item 24-465 but Deluxe. Each 24-466 5606
Same as item 24-465, but Premium. Each 24-467 7842
Same as item 24-465, but 90 cm sweep. Each 24-468 3530
Fan electric, Water proof with copper winding blades, Each 24-469 4864
canopy and rod including connection, provision of cable and
ceiling rose for fan, 140 and 120 cm sweep, (without
regulator) of approved type, supply and fixing.

Fan electric, Energy Efficient with remote control, AC/DC 220 Each 24-470 5873
V, copper winding, blades, canopy and rod including
connection, provision of cable and ceiling rose for fan, 140
and 120 cm sweep, (without regulator) of approved type,
supply and fixing.
Same as item 24-465 to 24-470, but fixing only. Each 24-471 259
Add to item 24-465 to 24-470 or 24-471, if removal only. Each 24-472 169

Wall Bracket Fan


Wall Bracket Fan Fancy with copper winding, plastic body 12” Each 24-473 3177
& 14” “Standard” Supply & fixing.
Same as item 24-473 but Deluxe. Each 24-474 3503
Same as item 24-473 but Premium. Each 24-475 3697
Wall Bracket Fan Fancy with copper winding, plastic body 20” Each 24-476 4954
& 24” “Standard” Supply & fixing.
Same as item 24-476, but Deluxe. Each 24-477 5825
Same as item 24-476, but Premium. Each 24-478 7461
Same as item 24-473 to 24-478, but fixing only. Each 24-479 86
Add to item 24-473 to 24-478 or 24-479, if removal only. Each 24-480 35

Cassette Fan AC
Cassette type fan 2’ x 2’ with copper winding & remote Each 24-481 7755
control, including connection, provision of cable best quality
supply and fixing.
Same as item 24-481, but fixing only. Each 24-482 104
Add to item 24-481 or 24-482, if removal only. Each 24-483 52
Switch/Socket
Switch, SP, Bakelite, Piano type, 5 A, all insulated, one way, Each 24-484 102
supply and fixing.
Switch, SP, Bakelite, Piano type, 5 A, all insulated two ways, Each 24-485 94
supply and fixing.
Socket outlet, 5 A, Bakelite, 2-pin, concealed type, supply and Each 24-486 88
fixing.
Dimmer, for ceiling fan, any sweep supply and fixing. Each 24-487 196
Same as item 24-484 to 24-487, but fixing only. Each 24-488 52
Add to item 24-484 to 24-487 or 24-488, if removal only. Each 24-489 26

Electric Motors
Motor electric AC, 400 V, 3 phase, 50 cycles, 1450 / 2900 Each 24-490 44624
RPM, 1 HP, solid shaft horizontal, motor efficiency class IE-2,
Insulation class F & Enclosure class IP55, supply and fixing.

Same as item 24-490, but 2 HP. Each 24-491 60068


Same as item 24-490, but 3 HP. Each 24-492 80706
Same as item 24-490, but 5 HP. Each 24-493 107526
Same as item 24-490, but 7.5 HP. Each 24-494 131198
Same as item 24-490, but 10 HP. Each 24-495 157946
Same as item 24-490, but 15 HP. Each 24-496 207746
Same as item 24-490, but 20 HP. Each 24-497 274130
Same as item 24-490, but 25 HP. Each 24-498 356348
Same as item 24-490, but 30 HP. Each 24-499 419828
Same as item 24-490, but 40 HP. Each 24-500 507428
Same as item 24-490, but 60 HP. Each 24-501 776228
Same as item 24-490, but 75 HP. Each 24-502 936428
Same as item 24-490, but 100 HP. Each 24-503 1274565
Same as item 24-490, but 125 HP. Each 24-504 1501365
Same as item 24-490 but 150 HP. Each 24-505 1841670
Same as item 24-490, but 180 HP. Each 24-506 2213670
Same as item 24-490 to 24-494, but fixing only. Each 24-507 398
Same as item 24-495 to 24-497, but fixing only. Each 24-508 986
Same as item 24-498 to 24-500, but fixing only. Each 24-509 2228
Same as item 24-501 or 24-502, but fixing only. Each 24-510 2250
Same as item 24-503 or 24-504, but fixing only. Each 24-511 2565
Same as item 24-505 or 24-506, but fixing only. Each 24-512 3270
Add to item 24-490 to 24-494 or 24-507, if removal only. Each 24-513 262

Add to item 24-495 to 24-497 or 24-508, if removal only. Each 24-514 654

Add to item 24-498 to 24-500 or 24-509, if removal only. Each 24-515 1480

Add to item 24-501 to 24-502 or 24-510, if removal only. Each 24-516 1480

Add to item 24-503 to 24-504 or 24-511, if removal only Each 24-517 1705

Add to item 24-505 to 24-506 or 24-512, if removal only. Each 24-518 2158

Rewinding
Rewinding of electric motor, SP, 50 cycle, 220/230 V, with Each 24-519 2564
copper insulated conductor complete, upto 1/2 HP.

Same as item 24-519, but over 1/2 HP and upto 1 HP. Each 24-520 4200
Same as item 24-519, but over 1 HP and upto 2 HP. Each 24-521 6000
Rewinding of electric motor, AC, 400 V, 3 phase, 50 cycles, Each 24-522 4200
1450/2900 RPM, complete as per original winding with
copper insulated conductor upto 1 HP.
Same as item 24-522, but over 1 HP and upto 3 HP. Each 24-523 6000
Same as item 24-522, but over 3 HP and upto 5 HP. Each 24-524 7200
Same as item 24-522 but over 5 HP and upto 7.5 HP. Each 24-525 12000
Same as item 24-522 but over 7.5 HP and upto 10 HP. Each 24-526 15385
Same as item 24-522 but over 10 HP and upto 15 HP. Each 24-527 21026
Same as item 24-522 but over 15 HP and upto 20 HP. Each 24-528 25128
Same as item 24-522 but over 20 HP and upto 25 HP. Each 24-529 29231
Same as item 24-522 but over 25 HP upto 30 HP. Each 24-530 37436
Same as item 24-522 but over 30 HP upto 40 HP. Each 24-531 44615
Same as item 24-522 but over 40 HP upto 50 HP. Each 24-532 55897
Same as item 24-522 but over 50 HP upto 60 HP. Each 24-533 64821
Same as item 24-522 but over 60 HP upto 70 HP. Each 24-534 75590
Same as item 24-522 but over 70 HP upto 80 HP. Each 24-535 86400
Rewinding of Ceiling fan, AC 220/ 230 V, 50 cycles, 140 cm Each 24-536 1920
sweep, complete as per original winding with copper
insulated conductor.
Same as item 24-536, but 120 cm sweep. Each 24-537 1846
Same as item 24-536, but 90 cm sweep. Each 24-538 1846
Starters
Direct Online starter, for motor, AC 400 V, 3 phase, 50 cycles, Each 24-539 5745
upto 5HP incl connecting up with incoming and outgoing
cables, supply and fixing.
Same as item 24-539, but fixing only. Each 24-540 345
Add to item 24-539 or 24-540, if removal only. Each 24-541 173
Auto Star Delta starter, for electric motor, AC 400 V, 3 phase, Each 24-542 40953
50 cycles, 7.5 to 10 HP, including connecting up with
incoming and outgoing cables, supply and fixing.
Same as item 24-542 but for 15 HP. Each 24-543 42518
Same as item 24-542, but for 20 HP. Each 24-544 44744
Same as item 24-542 but for 25 HP. Each 24-545 47692
Same as item 24-542 but for 30 HP. Each 24-546 53589
Same as item 24-542, but for 40 HP. Each 24-547 57897
Same as item 26-503, but for 50 HP. Each 24-548 66742
Same as item 24-542, but for 60 HP Each 24-549 71797
Same as item 24-542, but for 80 HP Each 24-550 95805
Same as item 24-542 but for 100 /125 HP. Each 24-551 127035
Same as item 24-542 to 24-546, but fixing only. Each 24-552 518
Same as item 24-547 to 24-551, but fixing only. Each 24-553 1035
Add to item 24-542 to 24-551 or 24-552, 24-553, if removal Each 24-554 431
only.
Conduit System
Bend / elbow, 20 mm dia, any type, cast or malleable iron, Each 24-555 109
stove enamelled or galvanized, supply and fixing.
Same as item 24-555, but 25 mm dia. Each 24-556 129
Same as item 24-555, but 40 mm dia. Each 24-557 222
Same as item 24-555, but 50 mm dia. Each 24-558 278
Junction Box circular, cast or malleable iron, stove enamelled Each 24-559 118
or galvanized, complete with cover, any number of outlets,
20 mm dia, supply and fixing.
Same as item 24-559, but 25 mm dia. Each 24-560 142
Same as item 24-559, but 40 mm dia. Each 24-561 250
Same as item 24-559, but 50 mm dia. Each 24-562 316
Junction Boxes/Board, rectangular 75x75 mm, cast or Each 24-563 160
melleable iron, stove enamelled or galvanized, complete with
cover, supply and fixing.
Same as item 24-563 but 75 x 100 mm. Each 24-564 184
Same as item 24-563 but 75 x 150 mm. Each 24-565 202
Same as item 24-563, but 100 x 175 mm. Each 24-566 202
Same as item 24-563, but 200 x 250 mm. Each 24-567 243
Same as item 24-563, but 250 x 300 mm. Each 24-568 261
Same as item 24-555 to 24-558, but fixing only. Each 24-569 52
Same as item 24-559 to 24-566, but fixing only. Each 24-570 52
Same as item 24-567 or 24-568, but fixing only. Each 24-571 69
Add to item 24-555 to 24-558 or 24-569, if removal only. Each 24-572 31

Add to item 24-559 to 24-566 or 24-570, if removal only. Each 24-573 31

Add to item 24-567 to 24-568 or 24-571, if removal only. Each 24-574 41

Lock nut, 12 mm dia, supply and fixing. Each 24-575 67


Same as item 24-575, but 20 mm dia. Each 24-576 82
Same as item 24-575, but 25 mm dia. Each 24-577 82
Same as item 24-575, but 30 mm dia. Each 24-578 94
Tee inspection, 20 mm dia, supply and fixing Each 24-579 106
Same as item 24-579, but 25 mm dia. Each 24-580 184
Same as item 24-579, but 40 mm dia. Each 24-581 316
Same as item 24-579, but 50 mm dia. Each 24-582 388
Saddles, 20 mm pressed steel system, supply and fixing. Each 24-583 94

Same as item 24-583, but 25 mm dia. Each 24-584 100


Same as item 24-583 but 40 mm dia. Each 24-585 138
Same as item 24-583, but 50 mm dia. Each 24-586 166
Same as item 24-575 to 24-586, but fixing only. Each 24-587 52
Add to item 24-575 to 24-586 or 24-587, if removal only. Each 24-588 35

Thimble cable socket, for single core cable, 6 mm², to 16 Each 24-589 91
mm2 supply and fixing.
Same as item 24-589, but for 25 mm² Each 24-590 97
Same as item 24-590, but for 35 mm Each 24-591 105
Same as item 24-591, but for 50 mm² Each 24-592 143
Same as item 24-591, but for 70 mm² Each 24-593 161
Same as item 24-591, but for 95 mm² Each 24-594 230
Same as item 24-591, but for 120 mm² Each 24-595 248
Same as item 24-591, but for 150 mm² Each 24-596 361
Same as item 24-591, but for 185 mm² Each 24-597 420
Same as item 24-591, but for 240 mm² Each 24-598 612
Same as item 24-591, but for 300 mm² Each 24-599 836
Same as item 24-589 to 24-591 but fixing only. Each 24-600 69
Same as item 24-592 to 24-593 but fixing only. Each 24-601 86
Same as item 24-594 to 24-595 but fixing only. Each 24-602 104
Same as item 24-596 to 24-597 but fixing only. Each 24-603 121
Same as item 24-598 to 24-599, but fixing only. Each 24-604 138
Add to item 24-589 to 24-593 or 24-600, 24-601 if removal Each 24-605 35
only.
Add to item 24-594 to 24-595 or 24-602, if removal only. Each 24-606 52

Add to item 24-596 to 24-597 or 24-603, if removal only. Each 24-607 62

Add to item 24-598 to 24-599 or 24-604, if removal only. Each 24-608 69

Wiring
Wiring in conduit surface, concealed, flame proof, with single Metre 24-609 46
core PVC insulated cable, installed and connected complete
(excluding conduit) single core cable, 1 mm², supply and
fixing.
Same as item 24-609, but 1.5 mm² cable. Metre 24-610 58
Same as item 24-609, but 2.5 mm² cable. Metre 24-611 78
Same as item 24-609, but 4mm² cable. Metre 24-612 99
Same as item 24-609, but 6 mm² cable. Metre 24-613 131
Same as item 24-609, but 10 mm² cable. Metre 24-614 203
Same as item 24-609, but 16mm² cable. Metre 24-615 289
Same as item 24-609, but 25 mm² cable. Metre 24-616 442
Same as item 24-609, but 35 mm² cable. Metre 24-617 575
Same as item 24-609, but 50 mm² cable. Metre 24-618 773
Same as item 24-609, but 70 mm² cable. Metre 24-619 1101
Same as item 24-609 to 24-614, but fixing only. Metre 24-620 28
Same as item 24-616 to 24-619, but fixing only. Metre 24-621 86
Add to item 24-609 to 24-614 or 24-620, if removal only. Metre 24-622 14

Add to item 24-616 to 24-619 or 24-621, if removal only. Metre 24-623 41

Multi Core Cable


Twin core cable 1 mm2 copper conductor, PVC insulated cable Metre 24-624 84
complete (excluding conduit), supply and fixing.

Same as item 24-624, but 1.5 mm² 24-625 108


Same as item 24-624, but 2.5 mm² Metre 24-626 143
Same as item 24-624, but 4 mm² Metre 24-627 228
Same as item 24-624, but 6 mm² Metre 24-628 261
Same as item 24-624, but 10 mm² Metre 24-629 421
Same as item 24-624 to 24-629, but fixing only. Metre 24-630 35
Add to item 24-624 to 24-629 or 24-630, if removal only. Metre 24-631 17

2
Cable 3 core 1 mm copper conductor PVC insulated cable Metre 24-632 126
complete (excluding conduit), supply and fixing.
2 Metre 24-633 165
Same as item 24-632 but 1.5 mm
Same as item 24-632 but 2.5 mm² Metre 24-634 218
Same as item 24-632 but 4 mm² Metre 24-635 303
Same as item 24-632, but 6 mm² Metre 24-636 417
Same as item 24-632, but 10 mm² Metre 24-637 666
Same as item 24-632 to 24-637, but fixing only. Metre 24-638 35
Add to item 24-632 to 24-637 or 24-639, if removal only. Metre 24-639 17

Cable 4 core PVC insulated cable complete, (excluding of Metre 24-640 186
conduit) 1.5 mm2.
Same as item 24-640 but 2.5 mm² Metre 24-641 285
Same as item 24-640 but 4 mm² Metre 24-642 421
Same as item 24-640 but 6 mm² Metre 24-643 539
Same as item 24-640 but 10 mm² Metre 24-644 847
Same as item 24-640 to 24-644, but fixing only. Metre 24-645 35
Add to item 24-640 to 24-644 or 24-645, if removal only. Metre 24-646 17

Flexible Cable Twin Core 300/500 V 23/0.0076. Metre 24-647 95


Same as item 24-647 but, 40/0.0076. Metre 24-648 110
Same as item 24-647 but, 70/0.0076. Metre 24-649 125
Same as item 24-647 but, 110/0.0076 Metre 24-650 175
Same as item 24-647 but, 162/0.0076 Metre 24-651 257
Same as item 24-647 to 24-651, but fixing only. Metre 24-652 35
Add to item 24-647 to 24-651 or 24-652, if removal only. Metre 24-653 17

Flexible Cable 3 Core 300/500 V 23/0.0076 supply and fixing Metre 24-654 114

Same as item 24-654 but k40/0.0076 Metre 24-655 138


Same as item 24-654 but 70/0.0076 Metre 24-656 174
Same as item 24-654 but 110/0.0076 Metre 24-657 224
Same as item 24-654 but 162/0.0076 Metre 24-658 337
Same as item 24-654 to 24-658, but fixing only. Metre 24-659 35
Add to item 24-654 to 24-658 or 24-659, if removal only. Metre 24-660 17

Flexible Cable 4 Core 300/500 V 23/0.0076 supply and fixing Metre 24-661 129

Same as item 24-661 but 40/0.0076 Metre 24-662 155


Same as item 24-661 but 70/0.0076 Metre 24-663 193
Same as item 24-661 but 110/0.0076 Metre 24-664 291
Same as item 24-661 but 162/0.0076 Metre 24-665 435
Same as item 24-661 to 24-665, but fixing only. Metre 24-666 35
Add to item 24-661 to 24-665 or 24-666, if removal only. Metre 24-667 17

Telephone cable, 2 pairs copper conductor 0.6 mm dia, PE Metre 24-668 58


insulated, PVC sheathed, supply and fixing.
Same as item 24-668, but 3 pairs. Metre 24-669 76
Same as item 24-668, but 4 pairs Metre 24-670 105
Same as item 24-668, but 5 pairs. Metre 24-671 127
Same as item 24-668 but 6 Pair Metre 24-672 143
Same as item 24-668 but 8 Pair Metre 24-673 180
Same as item 24-668 but 10 Pair Metre 24-674 218
Same as item 24-668 to 24-674, but fixing only. Metre 24-675 35
Add to item 24-668 to 24-674 or 24-675, if removal only. Metre 24-676 17

Television Coaxial cable 0.8mm2 SC, 2V, 75 ohm, RG 6 Supply Metre 24-677 67
& fixing.
Same as item 24-677 but RG 7 Metre 24-678 135
Same as item 24-677 but RG 11 Metre 24-679 160
Same as item 24-677 to 24-679, but fixing only. Metre 24-680 52
Add to item 24-677 to 24-679 or 24-680, if removal only. Metre 24-681 35

Step light Led, Aluminium die cast body, with grill and milky Metre 24-682 2236
glass 220/240 V, 3 watt, complete, supply & fixing.

Same as item 24-682, but fixing only. Metre 24-683 52


Add to item 24-682 or 24-683, if removal only. Metre 24-684 35
Exhaust Fan AC
Fan electric, AC, Exhaust, metal body with copper winding 25 Each 24-685 3102
cm & 30 cm, 220/230 V, with shutter, Metal duly enamel
painted, “Standard” supply and fixing.

Same as item 24-685 but Deluxe Each 24-686 3136


Same as item 24-686 but Premium Each 24-687 3497
Fan electric, AC, Exhaust, metal body with copper winding 40 Each 24-688 4619
cm & 45 cm, 220/230 V, with shutter, Metal enamel painted,
“Standard” supply and fixing.
Same as item 24-688 but Deluxe Each 24-689 4724
Same as item 24-688 but Premium Each 24-690 5084
Fan electric, AC, Exhaust, metal body with copper winding 50 Each 24-691 5606
cm & 60 cm 220/230 V, with shutter, Metal enamel painted,
“Standard” supply and fixing.
Same as item 24-691 but Deluxe Each 24-692 5704
Same as item 24-691 but Premium Each 24-693 6165
Same as item 24-685 to 24-690 but fixing only. Each 24-694 431
Same as item 24-691 to 24-694, but fixing only. Each 24-695 518
Add to item 24-685 to 24-694 or 24-695, if removal only. Each 24-696 242
Shutter Metal for Exhaust fan any size, enamel painted, Each 24-697 407
supply and fixing.
Same as item 24-697, but fixing only. Each 24-698 35
Add to item 24-697 or 24-698, if removal only. Each 24-699 25
Fan electric, AC, Exhaust, with copper winding, 220/230 V, Each 24-700 3017
SP, single/double way, 50 cycle, having plastic frame body
and blades, complete with cord operated switch, shutter and
fixing screws 20 cm & 25 cm “Standard” supply and fixing.

Same as item 24-700 but Deluxe. Each 24-701 3143


Same as item 24-700 but Premium. Each 24-702 3359
Fan electric, AC, Exhaust, with copper winding, 220/230 V, 24-703 3378
SP, double way 50 cycle, having plastic frame body and
blades, complete with cord operated switch, shutter and
fixing screws, 30 cm “Standard” supply and fixing.

Same as item 24-703 but Deluxe. Each 24-704 3480


Same as item 24-703 but Premium. Each 24-705 3810
Fan electric, AC. Exhaust with copper winding fresh air Each 24-706 2955
circulation (single way), 220/230 V, SP, 50 cycle, having
plastic frame, body and blades, complete with cord operated
switch, shutter and fixing screw, 30 cm “Standard”, supply
and fixing.
Same as item 24-706, but “Deluxe”. Each 24-707 3059
Same as item 24-706, but “Premium”. Each 24-708 3368
Same as item 24-700 to 24-708, but fixing only. Each 24-709 443
Add to item 24-700 to 24-708 or 24-709, if removal only. Each 24-710 114

Fan electric, AC, Exhaust, with copper winding, 30 cm, Flame Each 24-711 9664
proof, 220/230 V, SP, complete, supply and fixing.

Same as item 24-711, but 45 cm. Each 24-712 18064


Same as item 24-711, but 60 cm. Each 24-713 28864
Same as item 24-711 to 24-713, but fixing only. Each 24-714 664
Add to item 24-711 to 24-713 or 24-714, if removal only. Each 24-715 190

Air Compressors
Air compressor, single stage air cooled, mounted with Each 24-716 194310
horizontal receiving tank 300 lit capacity, max pressure 10
Kg/Cm2 (142 Psi), 3 cylinders, piston displacement 54.30 cfm,
fitted with auto pressure switch, pressure gauge and AC
electric motor 10 HP, 400 V, 3 phase, 50 cycles, supply and
fixing.
Same as item 24-716 but tank capacity 250 lit, 2 cylinders, Each 24-717 146310
displacement 39.50 cfm, with 7.5 HP electric motor.
Same as item 24-716, but tank capacity 160 lit, 3 cylinders, Each 24-718 116310
displacement 26.50 cfm, with 5 HP electric motor.

Same as item 24-716, but tank capacity 120 lit, 2 cylinders, Each 24-719 80310
displacement 16.40 cfm, with 3 HP electric motor.

Same as item 24-716, but tank capacity 100 lit, 2 cylinders, Each 24-720 76710
displacement 10.60 cfm, with 2 HP electric motor.

Same as item 24-716, but tank capacity 90 lit, 2 cylinders, Each 24-721 51810
displacement 8.50 cfm, with 1 HP electric motor single phase.

Same as item 24-721, but tank capacity 60 lit, 2 cylinders, Each 24-722 40710
displacement 3.7 cfm, with 0.5 HP electric motor.

Same as item 24-721, but tank capacity 300 lit, pressure 16 Each 24-723 170310
Kg/Cm2 (228 Psi) 3 cylinders, piston displacement 38.50 cfm
with 10 HP electric motor.
Same as item 24-723, but tank capacity 300 lit, 2 cylinders, Each 24-724 170310
displacement 26.30 cfm, 7.5 HP, Electric motor.

Same as item 24-724, but tank capacity 160 lit, 2 cylinders, Each 24-725 116310
displacement 20.40 cfm, 5 HP, Electric motor.

Same as item 24-716 to 24-725, but fixing only. Each 24-726 2310
Add to item 24-716 to 24-725 or 24-726, if removal only. Each 24-727 923

Pumping Set For Fuels


Pumping set, Centrifugal, multistage, for fuel, CI body and Each 24-728 1719240
impeller, stainless steel shaft and mechanical seal, capacity
300 gpm, 48.75M head, directly coupled with explosion proof
AC electric motor, 400 V, 3 phase, 50 cycles, 20 HP, mounted
on common base steel frame, with foundation bolts/nuts,
supply and fixing.
Same as item 24-728, but capacity 300 gpm, 43 M head, with Each 24-729 1546320
electric motor, 3 Phase, 20 HP.
Same as item 24-728, but capacity 200 gpm, 57 M head, with Each 24-730 1546320
electric motor, 3 Phase, 20 HP.
Same as item 24-730, but capacity 200 gpm, 49 M head, with Each 24-731 1304490
electric motor, 3 Phase, 15 HP.
Same as item 24-731, but capacity 200 gpm, 36 M head, with Each 24-732 987030
motor electric motor, 3 Phase, 10 HP.
Same as item 24-728 to 24-730, but fixing only. Each 24-733 3240
Same as item 24-731 to 24-732, but fixing only. Each 24-734 2310
Add to item 24-679 to 24-728 or 24-733, if removal only. Each 24-735 1620
Add to item 24-682 to 24-731 or 24-734, if removal only. Each 24-736 1155

Electric Geyser
Electric Geyser, 27 lit capacity, complete with thermostat, Each 24-737 11955
safety valve, supply and fixing.
Same as item 24-737, but 36 lit capacity. Each 24-738 12138
Same as item 24-737, but 45 lit capacity. Each 24-739 13242
Same as item 24-733 to 24-739, but fixing only. Each 24-740 915
Add to item 24-735 to 24-739 or 24-740, if removal only. Each 24-741 686

Instant Electric Water Geyser, capacity 6 lit/min, complete Each 24-742 12195
supply & fixing.
Same as item 24-742 but 8 liters. Each 24-743 15075
Same as item 24-742 but 10 liters. Each 24-744 15315
Same as item 24-742 to 24-744 but fixing only. Each 24-745 915
Add to item 24-742 to 24-744 or 24-745 if removal only. Each 24-746 630

Distribution Board, steel sheet (16 BG) with hinged over, Sqm 24-747 28118
having locking arrangement, enamel painted, suitable for
housing of different capacities of MCCBs etc (as required),
supply and fixing.
Same as item 24-747, but fixing only. Sqm 24-748 518
Add to item 24-747 or 24-748, if removal only. Sqm 24-749 345
Wiring in PVC Channels
PVC channel rectangular, 20 mm complete for (surface Metre 24-750 192
wiring), supply and fixing.
Same as item 24-750, but 25 mm. Metre 24-751 287
Same as item 24-750 but 40 mm Metre 24-752 352
Same as item 24-750, but 50 mm. Metre 24-753 520
Same as item 24-750, but 65 mm. Metre 24-754 610
Same as item 24-750, but 75 mm. Metre 24-755 697
Same as item 24-750, but 100 mm. Metre 24-756 925
Same as item 24-750 to 24-753 but fixing only. Metre 24-757 86
Same as item 24-754 to 24-756 but fixing only. Metre 24-758 173
Add to item 24-750 to 24-756 or 24-757, 24-758 if removal Metre 24-759 69
only.
Gang Switch Series (Standard)
One gang switch, 10 A, 250 V, including PVC/steel back box Each 24-760 338
with proper screws supply and fixing.
Same as item 24-760, but 2 gang, 10 A. Each 24-761 454
Same as item 24-761, but 3 gang, 10 A. Each 24-762 535
Same as item 24-762, but 4 gang, 10 A. Each 24-763 614
Same as item 24-763, but 6 gang, 10 A. Each 24-764 835
Same as item 24-764, but 8 gang, 10 A. Each 24-765 1087
One gang switch, 2 way 10 A, 250 V, including PVC/steel back Each 24-766 404
box with proper screws supply and fixing.
Gang fan dimmer 10 A, 250 V, including PVC/steel back box Each 24-767 336
with proper screws supply and fixing.
Gang TV/ Telephone socket, shuttered, including PVC/steel Each 24-768 470
back box with proper screws supply and fixing.

Twin TV/ Telephone socket, shuttered, including PVC/steel Each 24-769 525
back box with proper screws supply and fixing.

Single switch, one way, 10 A, 250 V gang type, including Each 24-770 217
PVC/steel back box with proper screws supply and fixing.

Same as item 24-770, but 2 ways, 10 A. Each 24-771 315


Bell push, single switch 10 A, 250 V, gang type, including Each 24-772 441
PVC/steel back box with proper screws supply and fixing.

One socket 2 pin 10 A, 250 V, gang type, including PVC/steel Each 24-773 378
back box with proper screws supply and fixing.

Dimmer for fan 250 V, including PVC/steel back box with Each 24-774 217
proper screws supply and fixing
TV / Telephone socket (gang type), including PVC/steel back Each 24-775 464
box with proper screws supply and fixing.
Ten gang switch 10 A 250 volts Complete, including PVC/steel Each 24-776 1207
back box with proper screws Supply & fixing
Same as item 24-776, but , 9 Switch +1 socket Each 24-777 1133
Same as item 24-776, but 8 Switch +2 socket Each 24-778 1133
Same as item 24-776, but 7 Switch +1 socket Each 24-779 1016
Same as item 24-776, but , 6 Switch +2 socket Each 24-780 1016
Same as item 24-776, but 5 Switch +1 socket Each 24-781 905
Same as item 24-776, but 4 Switch +2 socket Each 24-782 905
Same as item 24-776, but 3 Switch +3 socket Each 24-783 1010
Same as item 24-776, but 4 Switch +4 socket Each 24-784 1150
Same as item 24-776, but 1 Switch +1 socket Each 24-785 565
Same as item 24-776, but 2 Switch +1 socket Each 24-786 551
Same as item 24-776, but 1 Switch +2 socket Each 24-787 649
Same as item 24-776, but 2 Switch +2 socket Each 24-788 649
Same as item 24-776, but 3 Switch +1 socket Each 24-789 649
Same as item 24-760 to 24-789, but fixing only. Each 24-790 173
Add to item 24-760 to 24-789 or 24-790, if removal only. Each 24-791 104

Multi socket Light Plug, 10A, 250 V including PVC / steel back Each 24-792 693
box with proper screws Complete, supply and fixing.

Gang Power Socket, 15A, 250 V including PVC/steel back box Each 24-793 594
with proper screws complete, supply & fixing.
Gang Single Telephone Socket Complete, including PVC/steel Each 24-794 468
back box with proper screws supply & fixing.
Gang Double Telephone Socket Complete, including Each 24-795 474
PVC/steel back box with proper screws, supply & fixing.
Gang Single T V Socket Complete, including PVC/steel back Each 24-796 489
box with proper screws, supply & fixing.
Gang Double T V Socket Complete, including PVC/steel back Each 24-797 594
box with proper screws supply & fixing.
Gang Switch 2-pole 20 A, 250 V, Complete, including Each 24-798 672
PVC/steel back box with proper screws supply & fixing.
Same as item 24-792 to 24-799, but fixing only. Each 24-799 104
Add to item 24-792 to 24-790 or 24-799, if removal only. Each 24-800 69

Gang Switch Series Premium


One gang switch, 10A, 250 V, complete, including PVC/steel Each 24-801 320
back box with proper screws, supply & fixing.
Same as item 24-801, but Two gang switch. Each 24-802 450
Same as item 24-801, but Three gang switch. Each 24-803 668
Same as item 24-801, but Four gang switch. Each 24-804 1064
Same as item 24-801, but Five gang switch. Each 24-805 1262
Same as item 24-801, but Six gang switch. Each 24-806 1305
Same as item 24-801, but Eight gang switch. Each 24-807 1500
Same as item 24-801, but One gang switch 2 way, 10 A, 250 Each 24-808 424
V.
Same as item 24-801, but One gang Bell switch. Each 24-809 502
Same as item 24-801 to 24-809, but fixing only. Each 24-810 119
Add to item 24-801 to 24-809 or 24-810, if removal only. Each 24-811 104

Gang Telephone socket shuttered, including PVC/steel back Each 24-812 594
box with proper screws complete, supply & fixing.
Gang TV socket shuttered, including PVC/steel back box with Each 24-813 560
proper screws complete, supply & fixing.
Gang Twin TV/ Telephone socket shuttered, including Each 24-814 885
PVC/steel back box with proper screws complete, supply &
fixing.
Gang One gang switch + One Socket including PVC/steel back Each 24-815 711
box with proper screws complete, supply & fixing.

Same as item 24-815, but Two gang switch + One Socket Each 24-816 1103

Same as item 24-815, Three gang switch + One Socket Each 24-817 1190
Same as item 24-815, Four gang switch + One Socket Each 24-818 1388
Same as item 24-815, Five gang switch + One Socket Each 24-819 1718
Same as item 24-815, Six gang switch + One Socket Each 24-820 1849
Same as item 24-815, One gang switch + One Dimmer Each 24-821 1234
Same as item 24-815, Two gang switch + One Dimmer Each 24-822 1364
Same as item 24-815, Three gang switch + One Dimmer Each 24-823 1691

Same as item 24-815, Four gang switch + One Dimmer Each 24-824 1867
Same as item 24-815, Six gang switch + One Dimmer Each 24-825 2066
Same as item 24-815, Three gang Switch + one Dimmer + One Each 24-826 2197
Socket
Same as item 24-815, 5 Step Fan speed controller including Each 24-827 1169
PVC / steel back box with proper screws.
Same as item 24-815, Fan speed controller with Switch. Each 24-828 1082

Same as item 24-815, 5 Amp 3 Pin Switch Multi Socket. Each 24-829 690

Same as item 24-815, 10 Amp 3 Pin Switch Socket. Each 24-830 537
Same as item 24-815, 15 Amp 3 Pin Switch Socket. Each 24-831 624
Same as item 24-815, 20 Amp 3 Pin Switch Socket. Each 24-832 650
Same as item 24-812 to 24-832, but fixing only. Each 24-833 173
Add to item 24-812 to 24-832 or 24-833, if removal only. Each 24-834 104

Lawn / Garden light, complete with 23W, LED Bulb, plastic Each 24-835 6945
cover and mounting bracket (without pipe post), supply and
fixing.
Same as item 24-835, but fixing only Each 24-836 345
Add to item 24-835or 24-836, if removal only. Each 24-837 173
Wall Bracket, fancy, single, complete with holder and lamp, Each 24-838 2229
supply and fixing.
Same as item 24-838, but Double. Each 24-839 2709
Porch light, fancy, complete with holder and lamp, supply and Each 24-840 1509
fixing.
Gate light, fancy, complete with holder and lamp of approved Each 24-841 2941
type, supply and fixing.
Same as item 24-840 to 24-841, but fixing only. Each 24-842 69
Add to item 24-840 to 24-841 or 24-842, if removal only. Each 24-843 52

Obstruction light, with Red glass, holder, bracket, lamp and Each 24-844 6213
rod etc complete, supply and fixing.
Same as item 24-844, but fixing only. Each 24-845 345
Add to item 24-844 or 24-845, if removal only. Each 24-846 259
Phase Sequence Relay for electric motor, 3 Phase, 50 Cycles Each 24-847 10590
supply and fixing.
Same as item 24-847 but fixing only. Each 24-848 690
Add to item 24-847 or 24-848 if removal only. Each 24-849 345
Digital Ampere meter 600 A for LT panel, CT Operated supply Each 24-850 7269
& fixing
Analog Ampere meter 600 A for LT panel, CT Operated supply Each 24-851 2469
& fixing
Digital Volt meter 220/440 V for LT panel, CT Operated with Each 24-852 6669
selector switch, supply & fixing
Analog Volt meter 220/440 V for LT panel, CT Operated with Each 24-853 2469
Selector switch, supply & fixing
Same as item 24-850 to 24-853, but fixing only. Each 24-854 69
Add to item 24-850 to 24-853 or 24-854, if removal only. Each 24-855 35

Exit Light LED Complete with steel sheet powder coated, Each 24-856 9208
suitable operation on single phase with lithium battery for 12
hours back up, supply & Fixing.
Same as item 24-856, but fixing only. Each 24-857 80
Add to item 24-856 or 24-857, if removal only. Each 24-858 35
Magnetic Contactor 4 Pole
Magnetic Contactor operational Current 40 to 60 Amps 3 Each 24-859 9143
phase, 4 pole, 440 volts, complete approved type, supply and
fixing
Same as item 24-859 but, 50 to 80 Amps Each 24-860 13432
Same as item 24-859 but, 65 to 100 Amps Each 24-861 17358
Same as item 24-859 but 75 to 110 Amps Each 24-862 21234
Same as item 24-859 but 85 to 135 Amps Each 24-863 22518
Same as item 24-859 but 100 to 150 Amps Each 24-864 37638
Same as item 24-859 but 130 to 150 Amps Each 24-865 44779
Same as item 24-859 but 150 to 200 Amps Each 24-866 53438
Same as item 24-859 but 185 to 230 Amps Each 24-867 57697
Same as item 24-859 but 225 to 260 Amps Each 24-868 68312
Same as item 24-859 but 265 to 300 Amps Each 24-869 109235
Same as item 24-859 to 24-864, but fixing only. Each 24-870 259
Same as item 24-865 to 24-869, but fixing only. Each 24-871 345
Add to item 24-859to 24-864 or 24-870, if removal only. Each 24-872 138

Add to item 24-865 to 24-869 or 24-871, if removal only. Each 24-873 276

Magnetic Contactor 3 Pole


Magnetic Contactor, operational Current 9 to 20 Amps, 3 Each 24-874 2062
phase, 440 volts, 3 pole, complete approved type, supply and
fixing.
Same as item 24-874 but 12 to 20 Amps Each 24-875 2146
Same as item 24-874 but, 18 to 25 Amps Each 24-876 2776
Same as item 24-874 but, 22 to 32 Amps Each 24-877 3700
Same as item 24-874 but, 32 to 50 Amps Each 24-878 5128
Same as item 24-874 but, 40 to 60 Amps Each 24-879 6808
Same as item 24-874 but, 50 to 80 Amps Each 24-880 9428
Same as item 24-874 but, 65 to 100 Amps Each 24-881 10772
Same as item 24-874 but, 75 to 110 Amps Each 24-882 12438
Same as item 24-874 but, 85 to 135 Amps Each 24-883 14118
Same as item 24-874 but, 100 to 150 Amps Each 24-884 19158
Same as item 24-874 but, 130 to 150 Amps Each 24-885 23025
Same as item 24-874 but, 150 to 200 Amps Each 24-886 29918
Same as item 24-874 but, 185 to 230 Amps Each 24-887 37724
Same as item 24-874 but, 225 to 260 Amps Each 24-888 45705
Same as item 24-874 but, 265 to 300 Amps Each 24-889 60825
Same as item 24-874 to 24-880 but fixing only. Each 24-890 173
Same as item 24-881 to 24-885 but fixing only. Each 24-891 259
Same as item 24-886 to 24-889 but fixing only. Each 24-892 345
Add to item 24-874 to 24-880 or 24-890, if removal only. Each 24-893 138

Add to item 24-881 to 24-885 or 24-891, if removal only. Each 24-894 207

Add to item 24-886 to 24-889 or 24-892, if removal only. Each 24-895 276

Description Unit SI No. Rate (Rs)


Steel Tubular Pole
Digging holes, in ordinary soil, provision and erection in Each 25-1 35963
position and setting in 150 mm thick PCC 1:4:8 foundation
and 80 mm thick PCC 1:4:8, muffler all round for Steel tubular
un-galvanized pole 9 M long, complete with base plate, as
specified.
Same as item, 25-1, but galvanized. Each 25-2 46344
Same as item 25-1, but 12 M long, un-galvanized. Each 25-3 49489
Same as item 25-3, but 12 M long, galvanized. Each 25-4 64423
Same as item 25-1 or 25-2, but fixing only. Each 25-5 6550
Same as item 25-3 or 25-4, but fixing only. Each 25-6 7663
Add to item 25-1, 25-2 or 25-5, if removal only. Each 25-7 1138
Add to item 25-3, 25-4 or 25-6, if removal only. Each 25-8 1779
Digging holes, in ordinary soil, provision and erections in Each 25-9 41556
position and setting in 150 mm thick PCC 1:4:8 foundation
and 80 mm thick PCC 1:4:8 mufflers all round for steel
tubular, un-galvanized, single arm steel pole, 10.792 M long,
complete with base plate, as specified (figure 25-2).

Same as item 25-09, but galvanized. Each 25-10 47556


Same as item 25-09, but double arm 10.792 M long, un- Each 25-11 44372
galvanized (Figure 25-3).
Same as item 25-09, but double arm 10.792 M long, Each 25-12 51812
galvanized.
Same as item 25-9 or 25-10, but fixing only. Each 25-13 6756
Same as item 25-11 or 25-12, but fixing only. Each 25-14 7172
Add to item 25-9, 25-10 or 25-13 but fixing only. 25-15 2079
Add item 25-11, 25-12 or 25-14, if removal only. Each 25-16 2495
Add to item 25-1 to 25-16 if fixing in hard soil. Each 25-17 228
Add to item 25-1 to 25-16, if fixing in rock. Each 25-18 1670
Digging holes, in ordinary soil, provision and erection in Each 25-19 57385
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Round conical galvanized, 9 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-9, 25-10).
Same as item 25-19, but Double Arm (figure 25-8, 25-10). Each 25-20 60985

Digging holes, in ordinary soil, provision and erection in Each 25-21 65785
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but round conical, galvanized 10 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-9, 25-10).

Same as item 25-21, but Double Arm (figure 25-8, 25-10). Each 25-22 69385

Digging holes, in ordinary soil, provision and erection in Each 25-23 82945
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but round conical, galvanized, 12 metre
long, including “J” bolt set, single arm pole complete with
base plate as specified (figure 25-9, 25-10).

Same as item 25-23, but Double Arm (figure 25-8, 25-10). Each 25-24 85825

Digging holes, in ordinary soil, provision and erection in Each 25-25 58333
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 9 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).

Same as item 25-25, but Double Arm (figure 25-6, 25-10). Each 25-26 59929

Digging holes, in ordinary soil, provision and erection in Each 25-27 62089
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 10 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).

Same as item 25-27, but Double Arm (figure 25-6, 25-10). Each 25-28 73142

Digging holes, in ordinary soil, provision and erection in Each 25-29 80905
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 12 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).

Same as item 25-29, but Double Arm (figure 25-6, 25-10). Each 25-30 83905

Same as item 25-19, 25-25 but fixing only. Each 25-31 6985
Same as item 25-20, 25-26 but fixing only. Each 25-32 6985
Same as item 25-21, 25-27 but fixing only. Each 25-33 6985
Same as item 25-22 or 25-28 but fixing only. Each 25-34 6985
Same as item 25-23 or 25-29 but fixing only. Each 25-35 6985
Same as item 25-24 or 25-30 but fixing only. Each 25-36 6985
Add to item 25-19, 25-25 or 25-31 if removal only. Each 25-37 2079
Add to item 25-20, 25-26 or 25-32 if removal only. Each 25-38 2079
Add to item 25-21, 25-27 or 25-33 if removal only. Each 25-39 2079
Add to item 25-22, 25-28 or 25-34 if removal only. Each 25-40 2079
Add to item 25-23, 25-29 or 25-35 if removal only. Each 25-41 2079
Add to item 25-24, 25-30 or 25-36 if removal only. Each 25-42 2079
“L” Type Lattice Steel Pole
Digging hole, in ordinary soil, provision and erection of "L"- Each 25-43 29697
Type Lattice Steel pole, un-galvanized, including provision of
PCC 1:2:4, all as per WAPDA Drawing No. PDW/DF-10 (figure
25-11).
Same as item 25-43, but galvanized. Each 25-44 35097
Same as item 25-43 or 25-44, but fixing only. Each 25-45 6297
Add to item 25-43, 25-44 or 25-45, if removal only. Each 25-46 2079
Add to item 25-43 to 25-46, if fixed in hard soil. Each 25-47 228
Add to item 25-43 to 25-46, if fixed in rock. Each 25-48 1670
“H” Type Lattice Steel Pole
Digging hole in ordinary soil, provision and erection of "H" Each 25-49 42444
Type Lattice Steel pole, un-galvanized, including provision of
PCC 1:2:4, all as per WAPDA Drawing no. PDW/DF 11 (figure
25-12).
Same as item 25-49, but galvanized. Each 25-50 47244
Same as item 25-49 or 25-50, but fixing only. Each 25-51 8844
Add to item 25-49 to 25-50, 25-51 if removal only. Each 25-52 2079
Add to item 25-49 to 25-51, if fixed in hard soil. Each 25-53 228
Add to item 25-49 to 25-51, if fixed in rock. Each 25-54 1670
Digging hole in ordinary soil, provision and erection of "H" Each 25-55 120756
Type Lattice Steel pole 45 ft, un-galvanized, including
provision of PCC 1:2:4, all as specified.
Same as item 25-55, but galvanized. Each 25-56 136200
Same as item 25-55 or 25-56, but fixing only. Each 25-57 16860
Add to item 25-55 to 25-56, if removal only. Each 25-58 4568
Add to item 25-55 to 25-57, if fixed in hard soil. Each 25-59 270
Add to item 25-55 to 25-57, if fixed in rock. Each 25-60 3000
Cross Arm
Cross arms galvanized channels iron with clamp, washers, Each 25-61 4489
bolts and nuts etc Type "A", supply and fixing (figure 25-15).

Same as item 25-61, but Type 'B'. Each 25-62 4047


Same as item 25-61, but Type 'C'. Each 25-63 3687
Same as item 25-61, but Type 'D'. Each 25-64 2586
Same as item 25-61, but Type 'E'. Each 25-65 1397
Same as item 25-61, but 610 mm (for service bracket). Each 25-66 1345
Same as item 25-61, but fixing only. Each 25-67 409
Same as item 25-62 or 25-63, but fixing only. Each 25-68 327
Same as item 25-64, 25-65 or 25-66, but fixing only. Each 25-69 205
Add to item 25-61 to 25-63 or 25-67 to 25-68, if removal Each 25-70 327
only.
Add to item 25-64 to 25-66 or 25-69, if removal only. Each 25-71 205
Wooden Cross Arm, 2.44 M x 125 mm x 100 mm, complete Each 25-72 3032
with bracket and bolt/nuts, oil dipped, as specified for HT,
supply and fixing.
Same as item 25-72, but fixing only. Each 25-73 512
Add to item 25-72 or 25-73, if removal only. Each 25-74 512
Painting
Painting of steel pole, tubular and other type, excluding cross Each 25-75 1084
arms up to 12 M long, including anti corrosive paint, first
coat, (new or old work).
Same as item 25-75, but without anti corrosive paint. Each 25-76 716
Same as item 25-75, for second and subsequent coat, new or Each 25-77 534
old work.
Same as item 25-76, for second and subsequent coat, new or Each 25-78 506
old work.
Painting of service pole, first coat, (new or old work). Each 25-79 411
Same as item 25-79, for second and subsequent coat, (new Each 25-80 355
or old work).
Aerial Lines / Overhead Lines Insulators
Insulators, pin type LT, complete with pin, nuts and washers, Each 25-81 423
supply and fixing.
Same as item 25-81, but for HT upto 11 KV. Each 25-82 991
Insulator shackle, complete with "D" iron or suitable Each 25-83 516
arrangements /strap, LT, supply and fixing.
Disc insulator HT, complete with pin, nuts washers etc, 11 KV, Each 25-84 1767
supply and fixing.
Double Disc insulator HT, complete with pin etc, 11 KV, Each 25-85 2809
supply and fixing.
Same as item 25-81, but fixing only. Each 25-86 123
Same as item 25-82, but fixing only. Each 25-87 164
Same as item 25-83, but fixing only. Each 25-88 204
Same as item 25-84, but fixing only. Each 25-89 327
Same as item 25-85, but fixing only. Each 25-90 409
Add to item 25-81 or 25-86, if removal only. Each 25-91 93
Add to item 25-82, 25-83, 25-87 or 25-88, if removal only. Each 25-92 163

Add to item 25-84, 25-85, 25-89 or 25-90, if removal only. Each 25-93 327

Stays
Provision and fixing of stay assembly, stay wire (7/10 SWG), Each 25-94 6508
stay clamps, insulated including setting in earth, with PCC
1:3:6, complete, upto 13.75 M length.
Provision and fixing of stay flying, complete with stay wire Each 25-95 6219
(7/10 SWG), stay assembly, stay clamps, upto 15 M length.
Same as item 25-94, but fixing only. Each 25-96 2668
Same as item 25-94, but fixing only. Each 25-97 2668
Add to item 25-94 to 25-97, if removal only. Each 25-98 1023
Copper Conductor
Stringing, straining, tensioning and binding Copper Metre 25-99 137
conductor, bare solid or stranded 10 SWG, supply and fixing.

Same as item 25-99, but 8 SWG. Metre 25-100 193


Same as item 25-99, but 6 SWG. Metre 25-101 267
Same as item 25-99, but 4 SWG. Metre 25-102 369
Same as item 25-99, but 2 SWG. Metre 25-103 501
Same as item 25-99, but 1 SWG. Metre 25-104 586
Same as item 25-99, but 1/0 SWG. Metre 25-105 669
Same as item 25-99, but 2/0 SWG. Metre 25-106 779
Same as item 25-99, but 3/0 SWG. Metre 25-107 895
Same as item 25-99, but 4/0 SWG. Metre 25-108 1023
Same as item 25-99, but 70 mm2. Metre 25-109 909
Same as item 25-99, but 95 mm2. Metre 25-110 1258
Same as item 25-99, but 120 mm2. Metre 25-111 1527
Same as item 25-99, but 150 mm2. Metre 25-112 1888
Same as item 25-99, but MS, medium drawn galvanized wire, Metre 25-113 87
10 SWG.
Same as item 25-113, but 8 SWG. Metre 25-114 105
Same as item 25-113, but 6 SWG. Metre 25-115 132
Aluminium Conductor
Stringing, straining, tensioning and binding, Aluminium Metre 25-116 121
Conductor Steel Reinforced (ACSR) 6/0.083 aluminium and
1/0.083 steel (Squirrel), supply and fixing.
Same as item 25-116 but size 6/.132 aluminium and 1/.132 Metre 25-117 171
steel (Rabbit).
Same as item 25-116, but size 6/.183 aluminium and 1/.183 Metre 25-118 296
steel (Dog).
Same as item 25-99 to 25-103, but fixing only. Metre 25-119 74
Same as item 25-104 to 25-106, but fixing only. Metre 25-120 102
Same as item 25-107 to 25-112, but fixing only. Metre 25-121 147
Same as item 25-113 to 25-115, but fixing only. Metre 25-122 57
Same as item 25-116 to 25-118, but fixing only. Metre 25-123 123
Add to item 25-99 to 25-103 or 25-119, if removal only. Metre 25-124 73

Add to item 25-104 to 25-106 or 25-120, if removal only. Metre 25-125 102

Add to item 25-107 to 25-112 or 25-121, if removal only. Metre 25-126 147

Add to item 25-113 to 25-115 or 25-122, if removal only. Metre 25-127 57

Add to item 25-116 to 25-118 or 25-123, if removal only. Metre 25-128 123
Cable Electric aluminium - HT (3 core)
Cable electric HT, 11 KV stranded aluminium conductor, XLPE Metre 25-129 1991
insulated, extruded, PVC bedded, steel wire armoured and
PVC sheathed overall 3 core, 16 mm2, laid in trenches
complete with bricks, sand (excluding cost of excavation),
supply and fixing.
Same as item 25-129, but 25 mm². Metre 25-130 2227
Same as item 25-129, but 35 mm². Metre 25-131 2362
Same as item 25-129, but 50 mm². Metre 25-132 2610
Same as item 25-129, but 70 mm². Metre 25-133 2916
Same as item 25-129, but 95 mm². Metre 25-134 3300
Same as item 25-129, but 120 mm². Metre 25-135 3623
Same as item 25-129, but 150 mm². Metre 25-136 4216
Same as item 25-129, but 185 mm². Metre 25-137 4633
Same as item 25-129, but 240 mm². Metre 25-138 5234
Same as item 25-129, but 300 mm². Metre 25-139 5898
Cable electric HT, 11 KV stranded aluminium conductor XLPE Metre 25-140 1716
insulated, extruded PVC bedded, steel wire armoured and
2
PVC sheathed overall, 3 core 16 mm laid in GI/RCC Pipe/duct
(excluding cost of pipe/duct), supply and fixing.

Same as item 25-140, but 25 mm². Metre 25-141 1941


Same as item 25-140, but 35 mm². Metre 25-142 2065
Same as item 25-140, but 50 mm². Metre 25-143 2280
Same as item 25-140, but 70 mm². Metre 25-144 2586
Same as item 25-140, but 95 mm². Metre 25-145 2971
Same as item 25-140, but 120 mm². Metre 25-146 3293
Same as item 25-140, but 150 mm². Metre 25-147 3872
Same as item 25-140, but 185 mm². Metre 25-148 4288
Same as item 25-140, but 240 mm². Metre 25-149 4890
Same as item 25-140, but 300 mm². Metre 25-150 5554
Same as item 25-129 to 25-139 but fixing only. Metre 25-151 404
Same as item 25-140 to 25-150, but fixing only. Metre 25-152 74
Add to item 25-129 to 25-139, or 25-151, if removal only. Metre 25-153 83

Add to item 25-140 to 25-150, or 25-152, if removal only. Metre 25-154 74

Cable Electric aluminium - HT (Single core) aluminium


conductor
Cable electric HT 11 KV stranded aluminium conductor XLPE Metre 25-155 888
insulated, extruded PVC bedded, steel wire armoured and
PVC sheathed overall single core, 25 mm2 laid in trenches
complete with bricks, sand ( excluding cost of excavation)
supply and fixing.
Same as item 25-155, but 35 mm². Metre 25-156 921
Same as item 25-155, but 50 mm². Metre 25-157 985
Same as item 25-155, but 70 mm². Metre 25-158 1059
Same as item 25-155, but 95 mm². Metre 25-159 1209
Same as item 25-155, but 120 mm². Metre 25-160 1284
Same as item 25-155, but 150 mm². Metre 25-161 1386
Same as item 25-155, but 185 mm². Metre 25-162 1515
Same as item 25-155, but 240 mm². Metre 25-163 1684
Same as item 25-155, but 300 mm². Metre 25-164 1865
Cable electric HT, 11 KV stranded aluminium conductor XLPE Metre 25-165 577
insulated, extruded PVC bedded, steel wire-armoured and
2
PVC sheathed overall Single core, 25 mm Laid in GI/ RCC
pipe/duct (excluding cost of pipe/duct), supply and fixing.

Same as item 25-165, but 35 mm². Metre 25-166 610


Same as item 25-165, but 50 mm². Metre 25-167 673
Same as item 25-165, but 70 mm². Metre 25-168 754
Same as item 25-165, but 95 mm². Metre 25-169 904
Same as item 25-165, but 120 mm². Metre 25-170 993
Same as item 25-165, but 150 mm². Metre 25-171 1086
Same as item 25-165, but 185 mm². Metre 25-172 1210
Same as item 25-165, but 240 mm². Metre 25-173 1379
Same as item 25-165, but 300 mm². Metre 25-174 1560
Same as item 25-155 to 25-164, but fixing only. Metre 25-175 360
Same as item 25-165 to 25-174, but fixing only. Metre 25-176 74
Add to item 25-155 to 25-164 or 25-175, if removal only. Metre 25-177 49

Add to item 25-165 to 25-174 or 25-176, if removal only. Metre 25-178 41

Cable Electric Copper - HT (3 core)


Cable electric HT, 11 KV stranded copper conductor, XLPE Metre 25-179 2658
insulated, extruded, PVC bedded steel wire armoured and
PVC sheathed overall, 3 core 16 mm² laid in trenches
complete with bricks, sand, (excluding cost of excavation),
supply and fixing.
Same as item 25-179, but 3 core, 25 mm². Metre 25-180 3290
Same as item 25-179, but 3 core, 35 mm². Metre 25-181 3865
Same as item 25-179, but 3 core, 50 mm². Metre 25-182 4633
Same as item 25-179, but 3 core, 70 mm². Metre 25-183 5870
Same as item 25-179, but 3 core, 95 mm². Metre 25-184 7422
Same as item 25-179, but 3 core, 120 mm². Metre 25-185 8868
Same as item 25-179, but 3 core, 150 mm². Metre 25-186 10661
Same as item 25-179, but 3 core, 185 mm². Metre 25-187 13259
Same as item 25-179, but 3 core, 240 mm². Metre 25-188 15899
Same as item 25-179, but 3 core, 300 mm². Metre 25-189 19295
Cable electric HT, 11 KV stranded copper conductor XLPE Metre 25-190 2343
insulated, extruded, PVC bedded, steel wire armoured and
PVC sheathed overall, 3 core, 16 mm² laid in GI / RCC pipe/
duct (excluding cost of pipe/duct), supply and fixing.

Same as item 25-190, but 3 core, 25 mm². Metre 25-191 2981


Same as item 25-190, but 3 core, 35 mm². Metre 25-192 3543
Same as item 25-190, but 3 core, 50 mm². Metre 25-193 4309
Same as item 25-190, but 3 core, 70 mm². Metre 25-194 5545
Same as item 25-190, but 3 core, 95 mm². Metre 25-195 7106
Same as item 25-190, but 3 core, 120 mm². Metre 25-196 8538
Same as item 25-190, but 3 core, 150 mm². Metre 25-197 10316
Same as item 25-190, but 3 core, 185 mm². Metre 25-198 12476
Same as item 25-190, but 3 core, 240 mm². Metre 25-199 15555
Same as item 25-190, but 3 core, 300 mm². Metre 25-200 18984
Same as item 25-179 to 25-189, but fixing only. Metre 25-201 404
Same as item 25-190 to 25-200, but fixing only. Metre 25-202 74
Add to item 25-179 to 25-189, or 25-201, if removal only. Metre 25-203 83

Add to item 25-190 to 25-200, or 25-202, if removal only. Metre 25-204 74

Cable Electric Copper - HT (Single core)


Cable electric HT, 11 KV stranded Copper conductor XLPE Metre 25-205 1153
insulated, extruded PVC bedded, steel wire armoured and
2
PVC sheathed overall Single core, 16 mm laid in trenches
complete with bricks, sand (excluding cost of excavation)
supply and fixing.
Same as item 25-205, but 25 mm². Metre 25-206 1244
Same as item 25-205, but 35 mm². Metre 25-207 1415
Same as item 25-205, but 50 mm². Metre 25-208 1634
Same as item 25-205, but 70 mm². Metre 25-209 2045
Same as item 25-205, but 95 mm². Metre 25-210 2570
Same as item 25-205, but 120 mm². Metre 25-211 3020
Same as item 25-205, but 150 mm². Metre 25-212 3509
Same as item 25-205, but 185 mm². Metre 25-213 4174
Same as item 25-205, but 240 mm². Metre 25-214 5178
Same as item 25-205, but 300 mm². Metre 25-215 6258
Cable electric HT, 11 KV stranded copper conductor, XLPE Metre 25-216 854
insulated, extruded, PVC bedded, steel wire armoured and
PVC sheathed overall, Single core, 16 mm2 Laid in GI/ RCC
pipe/duct (excluding cost of pipe/duct), supply and fixing.

Same as item 25-216, but 25 mm². Metre 25-217 933


Same as item 25-216, but 35 mm². Metre 25-218 1107
Same as item 25-216, but 50 mm². Metre 25-219 1348
Same as item 25-216, but 70 mm². Metre 25-220 1734
Same as item 25-216, but 95 mm². Metre 25-221 2265
Same as item 25-216, but 120 mm². Metre 25-222 2715
Same as item 25-216, but 150 mm². Metre 25-223 3204
Same as item 25-216, but 185 mm². Metre 25-224 3869
Same as item 25-216, but 240 mm². Metre 25-225 4878
Same as item 25-216, but 300 mm². Metre 25-226 5953
Same as item 25-205 to 25-215, but fixing only. Metre 25-227 379
Same as item 25-216 to 25-226, but fixing only. Metre 25-228 74
Add to item 25-205 to 25-215 or 25-227, if removal only. Metre 25-229 60

Add to item 25-216 to 25-226 or 25-228, if removal only. Metre 25-230 74

Cable Electric – LT 4 Core


Cable electric LT PVC insulated, PVC sheathed, steel wire Metre 25-231 1515
armoured, overall PVC 600/1000 V, with stranded copper
conductor, 16 mm², 4 core, laid in trenches, complete with
bricks, sand (excluding cost of excavation), supply and fixing.

Same as item 25-231, but 4 core, 25 mm². Metre 25-232 2130


Same as item 25-231, but 4 core, 35 mm². Metre 25-233 2770
Same as item 25-231, but 4 core, 50 mm². Metre 25-234 3639
Same as item 25-231, but 4 core, 70 mm². Metre 25-235 4978
Same as item 25-231, but 4 core, 95 mm². Metre 25-236 6658
Same as item 25-231, but 4 core, 120 mm². Metre 25-237 8333
Same as item 25-231, but 4 core, 150 mm². Metre 25-238 10167
Same as item 25-231, but 4 core, 185 mm². Metre 25-239 12503
Same as item 25-231, but 4 core, 240 mm². Metre 25-240 16172
Same as item 25-231, but 4 core, 300 mm². Metre 25-241 20220
Cable electric LT PVC insulated, PVC sheathed, steel wire Metre 25-242 1240
armoured, overall PVC 600/1000 V, with stranded Copper
conductor, 16 mm², 4 core, laid in GI/RCC pipe/duct
(excluding cost of pipe/duct), supply and fixing.

Same as item 25-242, but 4 core, 25 mm². Metre 25-243 1844


Same as item 25-242, but 4 core, 35 mm². Metre 25-244 2474
Same as item 25-242, but 4 core, 50 mm². Metre 25-245 3342
Same as item 25-242, but 4 core, 70 mm². Metre 25-246 4670
Same as item 25-242, but 4 core, 95 mm². Metre 25-247 6350
Same as item 25-242, but 4 core, 120 mm². Metre 25-248 8014
Same as item 25-242, but 4 core, 150 mm². Metre 25-249 9848
Same as item 25-242, but 4 core, 185 mm². Metre 25-250 12173
Same as item 25-242, but 4 core, 240 mm². Metre 25-251 15841
Same as item 25-242, but 4 core, 300 mm². Metre 25-252 19878
Same as item 25-231 to 25-241, but fixing only. Metre 25-253 404
Same as item 25-242 to 25-252, but fixing only. Metre 25-254 74
Add to item 25-231 to 25-241 or 25-253, if removal only. Metre 25-255 74
Add to item 25-242 to 25-252 or 25-254, if removal only. Metre 25-256 74

Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-257 1426
overall PVC 600/1000 V, with stranded copper conductor 16
mm², 4 core laid in trenches complete with bricks, sand
(excluding cost of excavation), supply and fixing.

Same as item 25-257, but 4 core, 25 mm². Meter 25-258 2017


Same as item 25-257, but 4 core, 35 mm². Metre 25-259 2615
Same as item 25-257, but 4 core, 50 mm². Metre 25-260 3380
Same as item 25-257, but 4 core, 70 mm². Metre 25-261 4679
Same as item 25-257, but 4 core, 95 mm². Metre 25-262 6308
Same as item 25-257, but 4 core, 120 mm². Metre 25-263 7840
Same as item 25-257, but 4 core, 150 mm². Metre 25-264 9625
Same as item 25-257, but 4 core, 185 mm². Metre 25-265 11883
Same as item 25-257, but 4 core, 240 mm². Metre 25-266 15302
Same as item 25-257, but 4 core, 300 mm². Metre 25-267 19440
Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-268 1096
overall PVC 600/1000 V, with stranded Copper conductor, 16
mm², 4 core, laid in GI/RCC pipe/duct (excluding cost of
pipe/duct), supply and fixing.

Same as item 25-268, but 4 core, 25 mm². Metre 25-269 1687


Same as item 25-268, but 4 core, 35 mm². Metre 25-270 2285
Same as item 25-268, but 4 core, 50 mm². Metre 25-271 3050
Same as item 25-268, but 4 core, 70 mm². Metre 25-272 4349
Same as item 25-268, but 4 core, 95 mm². Metre 25-273 5978
Same as item 25-268, but 4 core, 120 mm². Metre 25-274 7510
Same as item 25-268, but 4 core, 150 mm². Metre 25-275 9295
Same as item 25-268, but 4 core, 185 mm². Metre 25-276 11554
Same as item 25-268, but 4 core, 240 mm². Metre 25-277 14972
Same as item 25-268, but 4 core, 300 mm². Metre 25-278 19111
Same as item 25-257 to 25-267, but fixing only. Metre 25-279 404
Same as item 25-268 to 25-278, but fixing only. Metre 25-280 74
Add to item 25-257 to 25-267 or 25-279, if removal only. Metre 25-281 83

Add to item 25-268 to 25-278 or 25-280, if removal only. Metre 25-282 74

Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-283 1982
armoured overall PVC 600/1000 V, with stranded copper
conductor, 25 mm², 3½ core, laid in trenches, complete with
bricks, sand (excluding cost of excavation), supply and fixing.

Same as item 25-283, but 3½ core, 35 mm². Metre 25-284 2479


Same as item 25-283, but 3½ core, 50 mm². Metre 25-285 3207
Same as item 25-283, but 3½ core, 70 mm². Metre 25-286 4441
Same as item 25-283, but 3½ core, 95 mm². Metre 25-287 5914
Same as item 25-283, but 3½ core, 120 mm². Metre 25-288 7516
Same as item 25-283, but 3½ core, 150 mm². Metre 25-289 8907
Same as item 25-283, but 3½ core, 185 mm². Metre 25-290 11067
Same as item 25-283, but 3½ core, 240 mm². Metre 25-291 14236
Same as item 25-283, but 3½ core, 300 mm². Metre 25-292 17927
Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-293 1696
armoured overall PVC 600/1000 V, with stranded Copper
conductor, 25 mm², 3½ core, laid in GI/RCC pipe/duct
(excluding cost of pipe/ duct), supply and fixing.

Same as item 25-293, but 3½ core, 35 mm². Metre 25-294 2182


Same as item 25-293, but 3½ core, 50 mm². Metre 25-295 2910
Same as item 25-293, but 3½ core, 70 mm². Metre 25-296 4133
Same as item 25-293, but 3½ core, 95 mm². Metre 25-297 5606
Same as item 25-293, but 3½ core, 120 mm². Metre 25-298 7197
Same as item 25-293, but 3½ core, 150 mm². Metre 25-299 8588
Same as item 25-293, but 3½ core, 185 mm². Metre 25-300 10737
Same as item 25-293, but 3½ core, 240 mm². Metre 25-301 13906
Same as item 25-293, but 3½ core, 300 mm². Metre 25-302 17585
Same as item 25-283 to 25-292, but fixing only. Metre 25-303 404
Same as item 25-293 to 25-302, but fixing only. Metre 25-304 74
Add to item 25-283 to 25-292 or 25-303, if removal only. Metre 25-305 74

Add to item 25-293 to 25-302 or 25-304, if removal only. Metre 25-306 74

Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-307 1863
overall PVC 600/1000 V, with stranded copper conductor 25
mm², but 3½ core, laid in trenches complete with bricks, sand
(excluding cost of excavation), supply and fixing.

Same as item 25-307, but 3½ core, 35 mm². Metre 25-308 2321


Same as item 25-307, but 3½ core, 50 mm². Metre 25-309 3041
Same as item 25-307, but 3½ core, 70 mm². Metre 25-310 4178
Same as item 25-307, but 3½ core, 95 mm². Metre 25-311 5581
Same as item 25-307, but 3½ core, 120 mm². Metre 25-312 7054
Same as item 25-307, but 3½ core, 150 mm². Metre 25-313 8398
Same as item 25-307, but 3½ core, 185 mm². Metre 25-314 10498
Same as item 25-307, but 3½ core, 240 mm². Metre 25-315 13575
Same as item 25-307, but 3½ core, 300 mm². Metre 25-316 17132
Cable electric LT, 600/1000 V, PVC insulated, un-armoured Metre 25-317 1533
overall stranded copper conductor 25 mm², 3½ core, laid in
GI/RCC pipe/duct (excluding cost of pipe/duct), supply and
fixing.
Same as item 25-317, but 3½ core, 35 mm². Metre 25-318 1991
Same as item 25-317, but 3½ core, 50 mm². Metre 25-319 2711
Same as item 25-317, but 3½ core, 70 mm². Metre 25-320 3848
Same as item 25-317, but 3½ core, 95 mm². Metre 25-321 5250
Same as item 25-317, but 3½ core, 120 mm². Metre 25-322 6724
Same as item 25-317, but 3½ core, 150 mm². Metre 25-323 8068
Same as item 25-317, but 3½ core, 185 mm². Metre 25-324 10168
Same as item 25-317, but 3½ core, 240 mm². Metre 25-325 13245
Same as item 25-317, but 3½ core, 300 mm². Metre 25-326 16802
Same as item 25-307 to 25-316, but fixing only. Metre 25-327 404
Same as item 25-317 to 25-326, but fixing only. Metre 25-328 74
Add to item 25-307 to 25-316 or 25-327, if removal only. Metre 25-329 83

Add to item 25-317 to 25-326 or 25-328, if removal only. Metre 25-330 74

Cable Electric LT single core copper conductor


Cable electric LT, 600/1000 V, stranded copper conductor Metre 25-331 633
insulated extruded PVC bedded, steel wire armoured and PVC
sheathed overall Single core, 16 mm2 laid in trenches
complete with bricks, sand (excluding cost of excavation)
supply and fixing.
Same as item 25-331, but 25 mm². Metre 25-332 774
Same as item 25-331, but 35 mm². Metre 25-333 923
Same as item 25-331, but 50 mm². Metre 25-334 1100
Same as item 25-331, but 70 mm². Metre 25-335 1425
Same as item 25-331, but 95 mm². Metre 25-336 1813
Same as item 25-331, but 120 mm². Metre 25-337 2190
Same as item 25-331, but 150 mm². Metre 25-338 2622
Same as item 25-331, but 185 mm². Metre 25-339 3170
Same as item 25-331, but 240 mm². Metre 25-340 4038
Same as item 25-331, but 300 mm². Metre 25-341 5399
Cable electric LT, 600/1000 V, stranded copper conductor Metre 25-342 322
insulated extruded PVC bedded, steel wire armoured and PVC
sheathed overall single core, 16 mm2 Laid in GI/ RCC
pipe/duct (excluding cost of pipe/duct), supply and fixing.

Same as item 25-342, but 25 mm². Metre 25-343 462


Same as item 25-342, but 35 mm². Metre 25-344 611
Same as item 25-342, but 50 mm². Metre 25-345 800
Same as item 25-342, but 70 mm². Metre 25-346 1114
Same as item 25-342, but 95 mm². Metre 25-347 1509
Same as item 25-342, but 120 mm². Metre 25-348 1878
Same as item 25-342, but 150 mm². Metre 25-349 2310
Same as item 25-342, but 185 mm². Metre 25-350 2859
Same as item 25-342, but 240 mm². Metre 25-351 3726
Same as item 25-342, but 300 mm². Metre 25-352 4684
Same as item 25-331 to 25-341, but fixing only. Metre 25-353 384
Same as item 25-342 to 25-352, but fixing only. Metre 25-354 74
Add to item 25-331 to 25-341 or 25-353, if removal only. Metre 25-355 67
Add to item 25-342 to 25-352 or 25-354, if removal only. Metre 25-356 74

Cable electric LT, 600/1000 V, stranded copper conductor Metre 25-357 597
insulated, extruded, PVC un-armoured and PVC sheathed
2
overall, single core, 16 mm laid in trenches complete with
bricks, sand (excluding cost of excavation) supply and fixing.

Same as item 25-357, but 25 mm². Metre 25-358 761


Same as item 25-357, but 35 mm². Metre 25-359 877
Same as item 25-357, but 50 mm². Metre 25-360 1074
Same as item 25-357, but 70 mm². Metre 25-361 1385
Same as item 25-357, but 95 mm². Metre 25-362 1770
Same as item 25-357, but 120 mm². Metre 25-363 2135
Same as item 25-357, but 150 mm². Metre 25-364 2570
Same as item 25-357, but 185 mm². Metre 25-365 3123
Same as item 25-357, but 240 mm². Metre 25-366 3983
Same as item 25-357, but 300 mm². Metre 25-367 4905
Cable electric LT, 600/1000 volts stranded copper conductor Metre 25-368 311
insulated, extruded, PVC Un-armoured and PVC sheathed
overall, single core, 16 mm2 laid in GI/ RCC pipe/duct
(excluding cost of pipe/duct), supply and fixing.

Same as item 25-368, but 25 mm². Metre 25-369 449


Same as item 25-368, but 35 mm². Metre 25-370 580
Same as item 25-368, but 50 mm². Metre 25-371 778
Same as item 25-368, but 70 mm². Metre 25-372 1089
Same as item 25-368, but 95 mm². Metre 25-373 1478
Same as item 25-368, but 120 mm². Metre 25-374 1828
Same as item 25-368, but 150 mm². Metre 25-375 2270
Same as item 25-368, but 185 mm². Metre 25-376 2812
Same as item 25-368, but 240 mm². Metre 25-377 3671
Same as item 25-368, but 300 mm². Metre 25-378 4619
Same as item 25-357 to 25-367 but fixing only. Metre 25-379 364
Same as item 25-368 to 25-378, but fixing only. Metre 25-380 74
Add to item 25-357 to 25-367 or 25-379, if removal only. Metre 25-381 49

Add to item 25-368 to 25-378 or 25-380, if removal only. Metre 25-382 74

Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-383 964
armoured, overall PVC, 600/1000 V with stranded aluminium
conductor, 25 mm2, 4 core, laid in trenches, complete with
bricks, sand (excluding cost of excavation), supply and fixing.

Same as item 25-383, but 35 mm². Metre 25-384 1094


Same as item 25-383, but 50 mm². Metre 25-385 1370
Same as item 25-383, but 70 mm². Metre 25-386 1625
Same as item 25-383, but 95 mm². Metre 25-387 1983
Same as item 25-383, but 120 mm². Metre 25-388 2371
Same as item 25-383, but 150 mm². Metre 25-389 2756
Same as item 25-383, but 185 mm². Metre 25-390 3219
Same as item 25-383, but 240 mm². Metre 25-391 3812
Same as item 25-383, but 300 mm². Metre 25-392 4454
Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-393 634
armoured, overall, PVC 600/1000 V, with stranded aluminium
conductor, 25 mm2, 4 core laid in GI / RCC pipe / duct
(excluding cost of pipe/duct), supply and fixing.

Same as item 25-393, but 35 mm². Metre 25-394 764


Same as item 25-393, but 50 mm². Metre 25-395 1040
Same as item 25-393, but 70 mm². Metre 25-396 1295
Same as item 25-393, but 95 mm². Metre 25-397 1653
Same as item 25-393, but 120 mm². Metre 25-398 2040
Same as item 25-393, but 150 mm². Metre 25-399 2426
Same as item 25-393, but 185 mm². Metre 25-400 2889
Same as item 25-393, but 240 mm². Metre 25-401 3482
Same as item 25-393, but 300 mm². Metre 25-402 4124
Same as item 25-383 to 25-392, but fixing only. Metre 25-403 404
Same as item 25-393 to 25-402, but fixing only. Metre 25-404 74
Add to item 25-383 to 25-392 or 25-403, if removal only. Metre 25-405 74

Add to item 25-393 to 25-402 or 25-404, if removal only. Metre 25-406 74

Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-407 707
overall, PVC 600/1000 V, with stranded aluminium
conductor, 25 mm², 4 core laid in trenches complete with
bricks, sand (excluding cost of excavation), supply and fixing.

Same as item 25-407, but 35 mm². Metre 25-408 792


Same as item 25-407, but 50 mm². Metre 25-409 924
Same as item 25-407, but 70 mm². Metre 25-410 1107
Same as item 25-407, but 95 mm². Metre 25-411 1362
Same as item 25-407, but 120 mm². Metre 25-412 1575
Same as item 25-407, but 150 mm². Metre 25-413 1841
Same as item 25-407, but 185 mm². Metre 25-414 2166
Same as item 25-407, but 240 mm². Metre 25-415 2689
Same as item 25-407, but 300 mm². Metre 25-416 3197
Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-417 377
overall PVC, 600/1000 V, with stranded aluminium
conductor, 25 mm², 4 core laid in GI/ duct pipe/duct
(excluding cost of pipe / duct), supply and fixing.

Same as item 25-417, but 35 mm². Metre 25-418 462


Same as item 25-417, but 50 mm². Metre 25-419 594
Same as item 25-417, but 70 mm². Metre 25-420 777
Same as item 25-417, but 95 mm². Metre 25-421 1031
Same as item 25-417, but 120 mm². Metre 25-422 1245
Same as item 25-417, but 150 mm². Metre 25-423 1511
Same as item 25-417, but 185 mm². Metre 25-424 1836
Same as item 25-417, but 240 mm². Metre 25-425 2358
Same as item 25-417, but 300 mm². Metre 25-426 2867
Same as item 25-407 to 25-416, but fixing only. Metre 25-427 404
Same as item 25-417 to 25-426, but fixing only. Metre 25-428 74
Add to item 25-407 to 25-416 or 25-427, if removal only. Metre 25-429 74

Add to item 25-417 to 25-426 or 25-428, if removal only. Metre 25-430 74

Cable electric LT single core (Aluminium conductor )

Cable electric LT, 600/1000 V, stranded aluminium Metre 25-431 456


conductor, insulated extruded, PVC bedded, steel wire
armoured and PVC sheathed overall single core, 16 mm2 laid
in trenches complete with bricks, sand (excluding cost of
excavation) supply and fixing.
Same as item 25-431, but 25 mm². Metre 25-432 495
Same as item 25-431, but 35 mm². Metre 25-433 524
Same as item 25-431, but 50 mm². Metre 25-434 576
Same as item 25-431, but 70 mm². Metre 25-435 641
Same as item 25-431, but 95 mm². Metre 25-436 715
Same as item 25-431, but 120 mm². Metre 25-437 801
Same as item 25-431, but 150 mm². Metre 25-438 882
Same as item 25-431, but 185 mm². Metre 25-439 1006
Same as item 25-431, but 240 mm². Metre 25-440 1209
Same as item 25-431, but 300 mm². Metre 25-441 1365
Cable electric LT, 600/1000 V, stranded aluminium conductor Metre 25-442 144
insulated extruded, PVC bedded, steel wire armoured and
2
PVC sheathed overall Single core, 16 mm laid in GI/ RCC
pipe/duct (excluding cost of pipe/duct), supply and fixing.

Same as item 25-442, but 25 mm². Metre 25-443 184


Same as item 25-442, but 35 mm². Metre 25-444 213
Same as item 25-442, but 50 mm². Metre 25-445 264
Same as item 25-442, but 70 mm². Metre 25-446 329
Same as item 25-442, but 95 mm². Metre 25-447 418
Same as item 25-442, but 120 mm². Metre 25-448 504
Same as item 25-442, but 150 mm². Metre 25-449 586
Same as item 25-442, but 185 mm². Metre 25-450 695
Same as item 25-442, but 240 mm². Metre 25-451 897
Same as item 25-442, but 300 mm². Metre 25-452 1011
Same as item 25-431 to 25-441 but fixing only. Metre 25-453 404
Same as item 25-442 to 25-452 but fixing only. Metre 25-454 74
Add to item 25-431 to 25-441 or 25-453 if removal only. Metre 25-455 56

Add to item 25-442 to 25-452 or 25-454 if removal only. Metre 25-456 74

Cable electric LT, 600/1000 V stranded aluminium conductor, Metre 25-457 429
insulated extruded PVC Un-armoured and PVC sheathed
overall single core, 16 mm2 laid in trenches complete with
bricks, sand (excluding cost of excavation) supply and fixing.

Same as item 25-457, but 25 mm². Metre 25-458 450


Same as item 25-457, but 35 mm². Metre 25-459 474
Same as item 25-457, but 50 mm². Metre 25-460 497
Same as item 25-457, but 70 mm². Metre 25-461 561
Same as item 25-457, but 95 mm². Metre 25-462 624
Same as item 25-457, but 120 mm². Metre 25-463 660
Same as item 25-457, but 150 mm². Metre 25-464 740
Same as item 25-457, but 185 mm². Metre 25-465 812
Same as item 25-457, but 240 mm². Metre 25-466 941
Same as item 25-457, but 300 mm². Metre 25-467 1078
Cable electric LT, 600/1000 V, stranded aluminium conductor Metre 25-468 118
insulated, extruded, PVC Un-armoured and PVC sheathed
overall Single core, 16 mm2 Laid in GI/ RCC pipe/duct
(excluding cost of pipe/duct), supply and fixing.

Same as item 25-468, but 25 mm². Metre 25-469 143


Same as item 25-468, but 35 mm². Metre 25-470 164
Same as item 25-468, but 50 mm². Metre 25-471 201
Same as item 25-468, but 70 mm². Metre 25-472 250
Same as item 25-468, but 95 mm². Metre 25-473 312
Same as item 25-468, but 120 mm². Metre 25-474 364
Same as item 25-468, but 150 mm². Metre 25-475 429
Same as item 25-468, but 185 mm². Metre 25-476 515
Same as item 25-468, but 240 mm². Metre 25-477 644
Same as item 25-468, but 300 mm². Metre 25-478 781
Same as item 25-457 to 25-467 but fixing only. Metre 25-479 41
Same as item 25-468 to 25-478 but fixing only. Metre 25-480 90
Add to item 25-457 to 25-467 or 25-479 if removal only. Metre 25-481 55

Add to item 25-468 to 25-478 or 25-480 if removal only. Metre 25-482 90

PVC, Straight joint


PVC, Straight joint LT, consisting of mould resin, padding Each 25-483 4195
tape, funnels and ferrules etc as specified for PVC un-
armoured LT cable 4 core, 16 mm², supply and fixing.

Same as item 25-483, but 25 mm² to 35 mm². Each 25-484 5718


Same as item 25-483, but 50 mm² to 70 mm². Each 25-485 7518
Same as item 25-483, but 95 mm² to 150 mm². Each 25-486 10077
Same as item 25-483, but 185 mm² to 300 mm². Each 25-487 10557
Same as item 25-483 to 25-485, but fixing only. Each 25-488 1518
Same as item 25-486 to 25-487, but fixing only. Each 25-489 2277
Add to item 25-483 to 25-485 or 25-488, if removal only. Each 25-490 276

Add to item 25-486 to 25-487 or 25-489, if removal only. Each 25-491 414

PVC Straight Joint LT, complete with tapes, ferrules and heat Each 25-492 4732
tubes etc, as specified for PVC armoured, LT Cable 4 core 16
mm², supply and fixing.
Same as item 25-492, but 25 mm² to 35 mm². Each 25-493 8526
Same as item 25-492, but 50 mm² to 70 mm². Each 25-494 10310
Same as item 25-492, but 95 mm² to 150 mm². Each 25-495 13186
Same as item 25-492, but 185 mm² to 300 mm². Each 25-496 17826
Same as item 25-492 to 25-493, but fixing only. Each 25-497 1518
Same as item 25-494, but fixing only. Each 25-498 2277
Same as item 25-495 to 25-496, but fixing only. Each 25-499 3036
Add to item 25-492 to 25-499, if removal only. Each 25-500 414
PVC, T-Service Joint LT, comprising mould resin, padding Each 25-501 6899
tape, funnels and ferrules etc, as specified for LT cable, 4
core, 16 mm2, supply and fixing.
Same as item 25-501, but 25 mm² to 50 mm² x 16 mm² to 25 Each 25-502 8764
mm².
Same as item 25-501, but 70 mm2 to 95 mm² x 35 to 50 Each 25-503 11877
mm².
Same as item 25-501, but 120 mm2 to 185 mm² x 70 mm2 to Each 25-504 22913
95 mm².
Same as item 25-501, but fixing only. Each 25-505 1822
Same as item 25-502, but fixing only. Each 25-506 2277
Same as item 25-503, but fixing only. Each 25-507 3036
Same as item 25-504, but fixing only. Each 25-508 3795
Add to item 25-501 to 25-508, if removal only. Each 25-509 276
PVC Heat Shrink (HS) Termination Kit, LT indoor / outdoor, Each 25-510 6022
consisting of heat shrink, boot lugs, clips and earth wire etc,
suitable for LT cables, 4 core, 16 mm2, PVC un-armoured,
supply and fixing.
Same as item 25-510, but 25 mm2 to 35 mm². Each 25-511 6325
2 Each 25-512 8277
Same as item 25-510, but 50 mm to 70 mm2.
Same as item 25-510, but 95 mm2 to 150 mm². Each 25-513 10229
2 Each 25-514 12075
Same as item 25-510, but 185 mm to 300 mm².
Same as item 25-510, but fixing only. Each 25-515 1822
Same as item 25-511, but fixing only. Each 25-516 2125
Same as item 25-512, but fixing only. Each 25-517 2277
Same as item 25-513, but fixing only. Each 25-518 2429
Same as item 25-514, but fixing only. Each 25-519 3795
Add to item 25-510 to 25-519, if removal only. Each 25-520 414
PVC Heat Shrink (HS) Termination kit LT, 4 core, Each 25-521 6562
indoor/outdoor, consisting of heat shrink boot, lugs, clips and
earth wire etc suitable for LT Cable, armoured, 16 mm²,
supply and fixing.
2 Each 25-522 7885
Same as item 25-521, but 25 mm to 35 mm².
Same as item 25-521, but 50 mm² to 70 mm². Each 25-523 10077
Same as item 25-521, but 95 mm2 to 150 mm². Each 25-524 11249
Same as item 25-521, but 185 mm2 to 300 mm². Each 25-525 13995
Same as item 25-521, but fixing only. Each 25-526 1822
Same as item 25-522, but fixing only. Each 25-527 2125
Same as item 25-523, but fixing only. Each 25-528 2277
Same as item 25-524, but fixing only. Each 25-529 2429
Same as item 25-525, but fixing only. Each 25-530 3795
Add to item 25-521 to 25-530, if removal only. Each 25-531 414
PVC Termination kit, HT 11 KV, indoor heat shrink, complete Each 25-532 13474
with tubes, copper Lugs, HT and PIB tapes and earth wire,
suitable for HT cables, XLPE, 3 core, 16 mm2 to 35 mm²,
supply and fixing.
Same as item 25-532, but for HT cable XLPE, 3 core, 50 to 95 Each 25-533 15492
mm².
Same as item 25-532, but for HT cable XLPE, 3 core, 120 Each 25-534 20664
to185 mm².
Same as item 25-532, but for HT cable XLPE, 3 core, 240 to Each 25-535 22910
300 mm².
PVC Termination kit, HT, 11 KV outdoor, heat shrink, Each 25-536 13474
complete with tubes, copper lugs, HT and PIB tapes and earth
wire suitable for HT cable, XLPE, 3 core, 16 mm² to 35 mm²,
supply and fixing.
Same as item 25-536 but 50 mm² to 95 mm². Each 25-537 15492
Same as item 25-536 but 120 mm² to 185 mm². Each 25-538 20664
Same as item 25-536 but 240 mm² to 300 mm². Each 25-539 22910
Same as item 25-532 or 25-536, but fixing only. Each 25-540 3274
Same as item 25-533 or 25-237, but fixing only. Each 25-541 4092
Same as item 25-534 or 25-538, but fixing only. Each 25-542 4464
Same as item 25-535 or 25-539, but fixing only. Each 25-543 4910
Add to item 25-532 to 25-543, if removal only. Each 25-544 414
PVC, Straight joint, HT, 11 KV for XLPE cable, consisting of Each 25-545 22474
mould resin, HT tape, semi conducting tape, ferrules and
earth wire etc suitable for HT cables, 3 core, 16 mm² to 35
mm², supply and fixing.
Same as item 25-545, but for HT cable XLPE, 3 core, 50 mm² Each 25-546 28092
to 95 mm².
Same as item 25-545, but for HT cable XLPE, 120 mm² to 185 Each 25-547 34310
mm².
Same as item 25-545, but for HT cable XLPE, 240 mm² to 300 Each 25-548 38595
mm².
Same as item 25-545, but fixing only. Each 25-549 3274
Same as item 25-546, but fixing only. Each 25-550 4092
Same as item 25-547, but fixing only. Each 25-551 4910
Same as item 25-548, but fixing only. Each 25-552 5115
Add to item 25-545 to 25-552, if removal only. Each 25-553 558
PVC, Straight joint Single core
PVC, Straight joint LT, consisting of mould resin, padding Each 25-554 1094
tape, funnels and ferrules etc as specified for PVC
unarmoured LT cable, Single core, 16 mm², supply and fixing.

Same as item 25-554, but 25 mm² to 35 mm². Each 25-555 1859


Same as item 25-554, but 50 mm² to 70 mm². Each 25-556 2465
Same as item 25-554, but 95 mm² to 150 mm². Each 25-557 3180
Same as item 25-554, but 185 mm² to 300 mm². Each 25-558 4440
Same as item 25-554 to 25-556, but fixing only. Each 25-559 380
Same as item 25-557 to 25-558, but fixing only. Each 25-560 569
Add to item 25-554 to 25-556 or 25-559, if removal only. Each 25-561 138

Add to item 25-557 to 25-558 or 25-560, if removal only. Each 25-562 207

PVC Straight Joint LT, complete with tapes, ferrules and heat Each 25-563 1411
tubes etc, as specified for PVC armoured LT cable, Single
core, 16 mm², supply and fixing.
Same as item 25-563, but 25 mm² to 35 mm². Each 25-564 2241
Same as item 25-563, but 50 mm² to 70 mm². Each 25-565 3135
Same as item 25-563, but 95 mm² to 150 mm². Each 25-566 4023
Same as item 25-563, but 185 mm² to 300 mm². Each 25-567 6487
Same as item 25-563 to 25-564, but fixing only. Each 25-568 380
Same as item 25-565, but fixing only. Each 25-569 759
Same as item 25-566 to 25-567, but fixing only. Each 25-570 759
Add to item 25-563 to 25-570, if removal only. Each 25-571 518
PVC, T-Service Joint, LT comprising mould resin, padding Each 25-572 2137
tape, funnels and ferrules etc, as specified for LT cable, Single
core, 16 mm2, supply and fixing.
Same as item 25-572, but 25 mm² to 50 mm² x 16 mm² to 25 Each 25-573 2236
mm².
Same as item 25-572, but 70 mm2 to 95 mm² x 35 to 50 Each 25-574 3128
mm².
Same as item 25-572, but 120 mm2 to 185 mm² x 70 mm2 to Each 25-575 5856
95 mm².
Same as item 25-572, but fixing only. Each 25-576 455
Same as item 25-573, but fixing only. Each 25-577 569
Same as item 25-574, but fixing only. Each 25-578 759
Same as item 25-575, but fixing only. Each 25-579 949
Add to item 25-572 to 25-579, if removal only. Each 25-580 138
PVC Heat Shrink (HS) Termination Kit, LT indoor/outdoor, Each 25-581 1323
consisting of heat shrink, boot lugs, clips and earth wire etc,
suitable for LT cables, Single core, 16 mm2 PVC un-armoured,
supply and fixing.
Same as item 25-581, but 25 mm2 to 35 mm². Each 25-582 2215
2 Each 25-583 2762
Same as item 25-581, but 50 mm to 70 mm².
2 Each 25-584 4340
Same as item 25-581, but 95 mm to 150 mm².
2 Each 25-585 6515
Same as item 25-581, but 185 mm to 300 mm².
Same as item 25-581, but fixing only. Each 25-586 455
Same as item 25-582, but fixing only. Each 25-587 531
Same as item 25-583, but fixing only. Each 25-588 569
Same as item 25-584, but fixing only. Each 25-589 607
Same as item 25-585, but fixing only. Each 25-590 949
Add to item 25-581 to 25-590, if removal only. Each 25-591 207
PVC Heat Shrink (HS) Termination kit LT, indoor/outdoor, Each 25-592 1530
consisting of heat shrink, boot, lugs, clips and earth wire etc
suitable for LT cable, armoured, 16 mm², Single core supply
and fixing.
Same as item 25-592, but 25 mm2 to 35 mm². Each 25-593 2623
Same as item 25-592, but 50 mm² to 70 mm². Each 25-594 3375
Same as item 25-592, but 95 mm2 to 150 mm². Each 25-595 3821
2 Each 25-596 5631
Same as item 25-592, but 185 mm to 300 mm².
Same as item 25-592, but fixing only. Each 25-597 449
Same as item 25-593, but fixing only. Each 25-598 531
Same as item 25-594, but fixing only. Each 25-599 569
Same as item 25-595, but fixing only. Each 25-600 607
Same as item 25-596, but fixing only. Each 25-601 949
Add to item 25-592 to 25-601, if removal only. Each 25-602 207
PVC Termination kit, HT, 11 KV, indoor heat shrink, complete Each 25-603 7557
with tubes, copper Lugs, HT and PIB tapes and earth wire,
2
suitable for HT cables, XLPE, Single core, 16 mm to 35 mm²,
supply and fixing.
Same as item 25-603, but 50 to 95 mm². Each 25-604 8840
Same as item 25-603, but 120 to185 mm². Each 25-605 9680
Same as item 25-603, 3 core, 240 to 300 mm². Each 25-606 11111
PVC Termination kit, HT, 11 KV outdoor, heat shrink, Each 25-607 8125
complete with tubes, copper lugs, HT and PIB tapes and earth
wire suitable for HT cable, XLPE, Single core, 16 mm² to 35
mm², supply and fixing.
Same as item 25-607, but 50 mm² to 95 mm². Each 25-608 11773
Same as item 25-607, but 120 mm² to 185 mm². Each 25-609 13652
Same as item 25-607, but 240 mm² to 300 mm². Each 25-610 14792
Same as item 25-603, or 25-607 but fixing only. Each 25-611 1362
Same as item 25-604, or 25-608 but fixing only. Each 25-612 1362
Same as item 25-605, or 25-609 but fixing only. Each 25-613 1637
Same as item 25-606, or 25-610 but fixing only. Each 25-614 1702
Add to item 25-603 to 25-614, if removal only. Each 25-615 279
PVC Straight joint, HT, 11 KV for XLPE cable, consisting of Each 25-616 11392
mould resin, HT tape, semi conducting tape, ferrules and
earth wire etc suitable for HT cables, single core, 16 mm² to
35 mm², supply and fixing.
Same as item 25-616, but for HT cable XLPE, 50 mm² to 95 Each 25-617 12268
mm².
Same as item 25-616, but for HT cable XLPE, 120 mm² to 185 Each 25-618 15295
mm².
Same as item 25-616, but for HT cable XLPE, 240 mm² to 300 Each 25-619 17616
mm².
Same as item 25-616, but fixing only. Each 25-620 1088
Same as item 25-617, but fixing only. Each 25-621 1362
Same as item 25-618, but fixing only. Each 25-622 1637
Same as item 25-619, but fixing only. Each 25-623 1702
Add to item 25-616 to 25-623, if removal only. Each 25-624 279
Danger sign, for HT and LT, not less than 250 mm x 125 mm Each 25-625 736
size, enamelled as required, supply and fixing.
Same as item 25-625, but fixing only. Each 25-626 256
Add to item 25-625 or 25-626, if removal only. Each 25-627 179
Non Climbable Device, as specified, (Figure 25-13), supply Each 25-628 1525
and fixing.
Same as item 25-628, but fixing only. Each 25-629 409
Add to item 25-628 or 25-629, if removal only. Each 25-630 304
Phase Indicating sign, red, blue or yellow as required, supply Each 25-631 529
and fixing.
Same as item 25-631, but fixing only. Each 25-632 49
Add to item 25-631 or 25-632, if removal only. Each 25-633 49
GI clamp for shackle, insulator or stay wire etc, of approved Each 25-634 308
type, supply and fixing.
Same as item 25-634, but fixing only. Each 25-635 123
Add to item 25-634 or 25-635, if removal only. Each 25-636 91
Lightning Arrester set of three pieces, complete, with all Each 25-637 17286
accessories, for 11 KV line, supply and fixing.
Same as item 25-637, but fixing only. Each 25-638 2046
Add to item 25-637 or 25-638, if removal only. Each 25-639 1432
Fuse D-link/cut off fuses assembly, set of three, complete Each 25-640 19838
with fuse, angle iron, nut and bolt, etc for 11 KV (assembly
unit), supply and fixing.
Same as item 25-640, but fixing only. Each 25-641 4092
Add to item 25-640 or 25-641, if removal only. Each 25-642 2864
Service Connection, complete with PVC insulated and PVC Metre 25-643 239
sheathed cable, 250 V, twin core, run on GI wire No 8 SWG
with brass/iron tinned clips of appropriate size at 20 cm
interval, size 2.5 mm², supply and fixing.
Same as item 25-643, but size, 4 mm². Metre 25-644 323
Same as item 25-643 or 25-644, but fixing only. Metre 25-645 61
Add to item 25-643 to 25-645, if removal only. Metre 25-646 43
Service Connection, complete with PVC insulated and PVC Metre 25-647 399
sheathed, 4 cores copper conductor, cable 2.5 mm², run on
No 8 SWG GI wire with brass/iron tinned clips of appropriate
size, at 10 cm interval, supply and fixing.

Same as item 25-647, but 4 mm², 4 core cable. Metre 25-648 545
Same as item 25-647 or 25-648, but fixing only. Metre 25-649 82
Add to item 25-647 to 25-649, if removal only. Metre 25-650 57
Service Bracket, comprising 50 mm dia tubing, GI/MS, upto Each 25-651 9645
4.50 M long with 900 bends, 2 nos, with hard wood bushes at
both ends, necessary clamps, bolts etc, without cross arms,
supply and fixing.
Same as item 25-651, but 6 M long. Each 25-652 11280
Same as item 25-651, but fixing only. Each 25-653 3069
Same as item 25-652, but fixing only. Each 25-654 3274
Add to item 25-651 or 25-653, if removal only. Each 25-655 2277
Add to item 25-652 or 25-654, if removal only. Each 25-656 2429
Stay Wire 3/10 SWG or 7/16 SWG upto 7 metre in length, Each 25-657 2647
complete with clamp and anchor bolts for service bracket,
supply and fixing.
Same as item 25-657, but above 7 metre and upto 10 M. Each 25-658 3584

Same as item 25-657 or 25-658, but fixing only. Each 25-659 409
Add to item 25-657 to 25-659, if removal only. Each 25-660 286
Steel Box (16 BG) for main switch, distribution board and Each 25-661 8365
meter, Type A, as per drawing in Figure 25-14, duly painted
with primer and two coats of synthetic enamel paint, supply
and fixing.
Same as item 25-662, but Type B Each 25-662 4404
Same as item 25-662 to 25-663, but fixing only. Each 25-663 174
Add to item 25-662 to 25-664, if removal only. Each 25-664 122
Fuse Aerial Porcelain up to 30 A, supply and fixing. Each 25-665 538
Same as item 25-665, but 60 A. Each 25-666 564
Same as item 25-665 or 25-667, but fixing only. Each 25-667 205
Add to item 25-665 to 25-667, if removal only. Each 25-668 143
Box guard MS, 10 SWG, supply and fixing. Each 25-669 281
Same as item 25-669, but 8 SWG. Each 25-670 302
Same as item 25-669, but 6 SWG. Each 25-671 359
Same as item 25-669 to 25-671, but fixing only. Each 25-672 123
Add to item 25-669 to 25-672, if removal only. Each 25-673 86
Cradle guard, 8 SWG for HT, supply and fixing. Each 25-674 192
Same as item 25-674, but fixing only. Each 25-675 102
Add to item 25-674 or 25-675, if removal only. Each 25-676 72
Cable marker, supply and fixing. Each 25-677 1456
Same as item 25-677, but fixing only. Each 25-678 256
Add to item 25-677 or 25-678, if removal only. Each 25-679 179
Jumpring, 8 SWG copper conductor, supply and fixing. Each 25-680 340
Same as item 25-680, but 6 SWG. Each 25-681 466
Same as item 25-680, but 4 SWG. Each 25-682 583
Same as item 25-680, but 2 SWG. Each 25-683 779
Same as item 25-680, but 1 SWG. Each 25-684 916
Same as item 25-680, but 1/0 SWG. Each 25-685 1060
Same as item 25-680, but 2/0 SWG. Each 25-686 1172
Same as item 25-680, but 3/0 SWG. Each 25-687 1424
Same as item 25-680, but 4/0 SWG. Each 25-688 1523
Same as item 25-680, but 70 mm². Each 25-689 1390
Same as item 25-680, but 95 mm². Each 25-690 1918
Same as item 25-680, but 120 mm². Each 25-691 2357
Same as item 25-680, but 150 mm². Each 25-692 2992
Same as item 25-680 to 25-682, but fixing only. Each 25-693 205
Same as item 25-683 to 25-686, but fixing only. Each 25-694 348
Same as item 25-687 to 25-689, but fixing only. Each 25-695 409
Same as item 25-690, but fixing only. Each 25-696 512
Same as item 25-691, but fixing only. Each 25-697 614
Same as item 25-692, but fixing only. Each 25-698 819
Add to item 25-680 to 25-692 or 25-693 to 25-698, if removal Each 25-699 164
only.
Power Transformer
Supply and erection in position on steel / PCC platform and Each 25-700 286332
connecting up, including testing and commissioning Power
Transformer, step down 11000/400/230 V, 3 phase 50 cycles
indoor/outdoor, 25 KVA Type “A” (excluding cost of
platform).
Same as item 25-700, but 25 KVA Type “B”. Each 25-701 256812
Same as item 25-700, but 25 KVA Type “C”. Each 25-702 193632
Same as item 25-700, but 50 KVA, Type “A”. Each 25-703 436092
Same as item 25-700, but 50 KVA Type “B”. Each 25-704 355092
Same as item 25-700, but 50 KVA Type “C”. Each 25-705 284892
Same as item 25-700, but 100 KVA, Type “A”. Each 25-706 623292
Same as item 25-700, but 100 KVA Type “B”. Each 25-707 523572
Same as item 25-700, but 100 KVA Type “C”. Each 25-708 466092
Same as item 25-700, but 150 KVA, Type “A”. Each 25-709 838458
Same as item 25-700, but 150 KVA Type “B”. Each 25-710 673038
Same as item 25-700, but 150 KVA Type “C”. Each 25-711 567738
Same as item 25-700, but 200 KVA, Type “A”. Each 25-712 1051578
Same as item 25-700, but 200 KVA Type “B”. Each 25-713 799398
Same as item 25-700, but 200 KVA Type “C”. Each 25-714 680058
Same as item 25-700, but 250 KVA, Type “A”. Each 25-715 1264887
Same as item 25-700, but 250 KVA Type “B”. Each 25-716 865647
Same as item 25-700, but 250 KVA Type “C”. Each 25-717 781408
Same as item 25-700, but 300 KVA Type “A”. Each 25-718 1478196
Same as item 25-700, but 300 KVA Type “B”. Each 25-719 917856
Same as item 25-700, but 300 KVA Type “C”. Each 25-720 889776
Same as item 25-700, but 400 KVA, Type “A”. Each 25-721 1898676
Same as item 25-700, but 400 KVA Type “B”. Each 25-722 1374156
Same as item 25-700, but 400 KVA Type “C”. Each 25-723 1320276
Same as item 25-700, but 500 KVA, Type “A”. Each 25-724 2224788
Same as item 25-700, but 500 KVA Type “B”. Each 25-725 1544748
Same as item 25-700, but 500 KVA Type “C”. Each 25-726 1478388
Same as item 25-700, but 630 KVA, Type “A”. Each 25-727 2550900
Same as item 25-700, but 630 KVA Type “B”. Each 25-728 1673220
Same as item 25-700, but 630 KVA Type “C”. Each 25-729 1560900
Same as item 25-700, but 1000 KVA, Type “A”. Each 25-730 3040500
Same as item 25-700, but 1000 KVA Type “B”. Each 25-731 2059332
Same as item 25-700, but 1000 KVA Type “C”. Each 25-732 1930500
Same as item 25-700 to 25-702, but fixing only. Each 25-733 4092
Same as item 25-703 to 25-705, but fixing only. Each 25-734 4092
Same as item 25-706 to 25-708, but fixing only. Each 25-735 4092
Same as item 25-709 to 25-711, but fixing only. Each 25-736 6138
Same as item 25-712 to 25-714, but fixing only. Each 25-737 6138
Same as item 25-715 to 25-717, but fixing only. Each 25-738 9207
Same as item 25-718 to 25-720, but fixing only. Each 25-739 12276
Same as item 25-721 to 25-723, but fixing only. Each 25-740 12276
Same as item 25-724 to 25-726, but fixing only. Each 25-741 14433
Same as item 25-727 to 25-729, but fixing only. Each 25-742 16500
Same as item 25-730 to 25-732, but fixing only. Each 25-743 16500
Add to item 25-700 to 25-708 or 25-733 to 25-735 if removal Each 25-744 4092
only.
Add to item 25-709 to 25-714 or 25-736 to 25-737, if removal Each 25-745 6138
only.
Add to item 25-715 to 25-717 or 25-738, if removal only. Each 25-746 9207

Add to item 25-718 to 25-723 or 25-739 to 25-740, if removal Each 25-747 12276
only.
Add to item 25-724 to 25-726 or 25-741, if removal only. Each 25-748 16500

Add to item 25-727 to 25-732 or 25-742 to 25-743, if removal Each 25-749 16500
only.
Power Transformers – Pad Mounted
Supply, fixing, testing and commissioning of Power Each 25-750 831570
Transformer pad mounted type, oil immersed, naturally
cooled, step down 11000/400/230 volts 50 cycles, comprising
with High/Low Voltage compartments and controls, 25 KVA,
Type “A” (excluding pad), supply and fixing.

Same as item 25-750, but 25 KVA Type “B”. Each 25-751 408444
Same as item 25-750, but 25 KVA Type “C”. Each 25-752 322092
Same as item 25-728, but 50 KVA, Type “A”. Each 25-753 998332
Same as item 25-750, but 50 KVA Type “B”. Each 25-754 572712
Same as item 25-750, but 50 KVA Type “C”. Each 25-755 468492
Same as item 25-728, but 100 KVA, Type “A”. Each 25-756 1165650
Same as item 25-750, but 100 KVA Type “B”. Each 25-757 902652
Same as item 25-750, but 100 KVA Type “C”. Each 25-758 695292
Same as item 25-728, but 150 KVA, Type “A”. Each 25-759 1400695
Same as item 25-750, but 150 KVA Type “B”. Each 25-760 1057092
Same as item 25-750, but 150 KVA Type “C”. Each 25-761 1027608
Same as item 25-728, but 200 KVA, Type “A”. Each 25-762 1735334
Same as item 25-750, but 200 KVA Type “B”. Each 25-763 1269738
Same as item 25-750, but 200 KVA Type “C”. Each 25-764 1255698
Same as item 25-728, but 250 KVA, Type “A”. Each 25-765 2124492
Same as item 25-750, but 250 KVA Type “B”. Each 25-766 1353978
Same as item 25-750, but 250 KVA Type “C”. Each 25-767 1190538
Same as item 25-728, but 300 KVA, Type “A”. Each 25-768 2322150
Same as item 25-750, but 300 KVA Type “B”. Each 25-769 1437336
Same as item 25-750, but 300 KVA Type “C”. Each 25-770 1314276
Same as item 25-728, but 400 KVA, Type “A”. Each 25-771 2707048
Same as item 25-750, but 400 KVA Type “B”. Each 25-772 2048076
Same as item 25-750, but 400 KVA Type “C”. Each 25-773 1734276
Same as item 25-728 but 500 KVA, Type “A”. Each 25-774 3298907
Same as item 25-750, but 500 KVA Type “B”. Each 25-775 2415228
Same as item 25-750, but 500 KVA Type “C”. Each 25-776 1904388
Same as item 25-728, but 630 KVA, Type “A”. Each 25-777 3733461
Same as item 25-750, but 630 KVA Type “B”. Each 25-778 2613900
Same as item 25-750, but 630 KVA Type “C”. Each 25-779 2114100
Same as item 25-728, but 1000 KVA, Type “A”. Each 25-780 4523818
Same as item 25-750, but 1000 KVA Type “B”. Each 25-781 3173388
Same as item 25-750, but 1000 KVA Type “C”. Each 25-782 2892588
Same as item 25-750 to 25-752, but fixing only. Each 25-783 4092
Same as item 25-753 to 25-755,, but fixing only. Each 25-784 4092
Same as item 25-756 to 25-758, but fixing only. Each 25-785 4092
Same as item 25-759 to 25-761, but fixing only. Each 25-786 4092
Same as item 25-762 to 25-764, but fixing only. Each 25-787 6138
Same as item 25-765 to 25-767, but fixing only. Each 25-788 12276
Same as item 25-768 to 25-770, but fixing only. Each 25-789 12276
Same as item 25-771 to 25-773, but fixing only. Each 25-790 12276
Same as item 25-774 to 25-776, but fixing only. Each 25-791 14388
Same as item 25-777 to 25-779, but fixing only. Each 25-792 16350
Same as item 25-780 to 25-782, but fixing only. Each 25-793 16350
Add to item 25-750 to 25-761 or 25-783 to 25-786, if removal Each 25-794 3069
only.
Add to item 25-762 to 25-767 or 25-787 to 25-788, if removal Each 25-795 4092
only.
Add to item 25-768 to 25-770 or 25-789, if removal only. Each 25-796 9207

Add to item 25-771 to 25-773, or 25-790, if removal only. Each 25-797 9207

Add to item 25-774 to 25-776, or 25-791, if removal only. Each 25-798 10791

Add to item 25-777 to 25-782, or 25-792 to 25-793, if Each 25-799 12263


removal only.
DRY TYPE TRANSFORMER INSULATION CLASS "F" COPPER
WINDING
Supply, erection, Installation, Testing and Commissioning of Each 25-800 3088092
Dry type indoor, power transformer having continuous rating
of 11000/400/230 volt, 3 phase, 50 HZ, having off load tap
changing arrangement on high voltage side. The taping to be
provided for variation of high voltage from -10% to +5% in
seven step of 2.5% each, for "F" Class insulation, Copper
winding Capacity 100 KVA.

Same as Item 25-800 but capacity 200 KVA. Each 25-801 3414138
Same as Item 25-800 but capacity 400 KVA. Each 25-802 4488276
Same as Item 25-800 but capacity 500 KVA. Each 25-803 4814388
Same as Item 25-800 but capacity 630 KVA. Each 25-804 4934338
Same as Item 25-800 but capacity 800 KVA. Each 25-805 5222388
Same as Item 25-800 but capacity 1000 KVA. Each 25-806 6722388
DRY TYPE TRANSFORMER INSULATION CLASS "F" Aluminium
WINDING
Supply, erection, Installation, Testing and Commissioning of Each 25-807 2380092
Dry type indoor, power transformer having continuous rating
of 11000/400/230 volt, 3 phase, 50 HZ, having off load tap
changing arrangement on high voltage side. The taping to be
provided for variation of high voltage from -10% to +5% in
seven step of 2.5% each, for "F" Class insulation, Aluminium
winding Capacity 100 KVA.

Same as Item 25-807 but capacity 200 KVA. Each 25-808 2574138
Same as Item 25-807 but capacity 400 KVA. Each 25-809 2928276
Same as Item 25-807 but capacity 500 KVA. Each 25-810 3374388
Same as Item 25-807 but capacity 630 KVA. Each 25-811 3746388
Same as Item 25-807 but capacity 800 KVA. Each 25-812 4070388
Same as Item 25-807 but capacity 1000 KVA. Each 25-813 4238388
Same as Item 25-800 to 25-807 but fixing only. Each 25-814 4092
Same as Item 25-801 or 25-808 but fixing only. Each 25-815 6138
Same as Item 25-802 or 25-809 but fixing only. Each 25-816 12276
Same as Item 25-803 or 25-810 but fixing only. Each 25-817 14388
Same as Item 25-804 or 25-811 but fixing only. Each 25-818 16500
Same as Item 25-805 or 25-812 but fixing only. Each 25-819 16500
Same as Item 25-806 or 25-813 but fixing only. Each 25-820 16500
Add to item 25-800, 25-807 or 25-814 if removal only. Each 25-821 3039
Add to item 25-801, 25-808 or 25-815 if removal only. Each 25-822 4603
Add to item 25-802, 25-809 or 25-816 if removal only. Each 25-823 6138
Add to item 25-803, 25-810 or 25-817 if removal only. Each 25-824 10791
Add to item 25-804, 25-811 or 25-818 if removal only. Each 25-825 10791
Add to item 25-805, 25-812 or 25-819 if removal only. Each 25-826 10791
Add to item 25-806, 25-813 or 25-820 if removal only. Each 25-827 10791
Transformer Single Phase
Supply, fixing and erection in position on steel/PCC platform Each 25-828 244092
and connecting up, including testing and commissioning
Power Transformer, step down 11000/230 V, single phase,
50 cycles, indoor/outdoor, 25 KVA (excluding cost of
platform).
Same as item 25-828, but 50 KVA. Each 25-829 334092
Same as item 25-828, but 100 KVA. Each 25-830 502092
Same as item 25-828, but fixing only. Each 25-831 4092
Same as item 25-829, but fixing only. Each 25-832 4092
Same as item 25-830, but fixing only. Each 25-833 4092
Add to item 25-828 to 25-833 if removal only. Each 25-834 4092
Potential Transformer
Potential Transformer (PT), 11000 / 230 V or 110 V, for HT Each 25-835 73023
panel, supply and fixing.
Same as item 25-835, but fixing only. Each 25-836 1023
Add to item 25-835 or 25-836, if removal only. Each 25-837 716
HT / LT Current Transformers (CT)
Current Transformer (CT), Ratio 25/5, 35/5 or 75/5 A, for HT Each 25-838 57471
panel, supply and fixing.
Same as item 25-838, but CT Ratio 100/5 A Each 25-839 49983
Same as item 25-838, but CT Ratio 25/5 A for LT panel. Each 25-840 2432
Same as item 25-838 but CT Ratio 35/5 A to 1000/5 A, for LT Each 25-841 5792
panel.
Same as item 25-838 to 25-839, but fixing only Each 25-842 1023
Same as item 25-840 to 25-841, but fixing only. Each 25-843 512
Add to item 25-838 to 25-843, if removal only. Each 25-844 512
LT Switch Board with MCCB
LT Switch Board with 1250 A, MCCB, incoming switch, Each 25-845 612883
complete with thermal over current release, adjustable
magnetic short circuit release, shunt trip coil, CT ratio
1000/5, volt meter and Amp-meter with selector switches,
earth fault relays, complete with TP, neutral common bus
bar, including upto 06 outgoing with neutral link, 3-Phase
MCCB switches, switch board steel sheet factory wired,
painted and installed, complete including making connection,
supply and fixing.

Same as item 25-845, but 1000 A, upto 05 outgoings. Each 25-846 570307
Same as item 25-845, but 800 A, upto 04 outgoing. Each 25-847 457486
Same as item 25-845, but 600 A, upto 04 outgoing. Each 25-848 371889
Same as item 25-845, but 400 A, upto 03 outgoing. Each 25-849 276448
Same as item 25-845 to 25-848, but fixing only. Each 25-850 6204
Same as item 25-849, but fixing only. Each 25-851 4653
Add to item 25-845 to 25-851, if removal only. Each 25-852 3069
LT Panel without MCCB
LT Panel without MCCB, ACB etc complete with digital Each 25-853 29943
Ampere, volts meters, Selector switches, Indication lamps, 3 x
current transformers, cable Gland, copper bus bar, 3 phase
and neutral link, including proper nuts and bolts with spring
washers mounted on proper insulator, Electrical interlocking,
steel sheet powder coated 3 mm thick, switch for operation
on 3 phase, 4 wire, 50 cycles 400-600 volts, 100 Amps.
Supply & Fixing.

Same as Item 25-853, But up to 150 Amps. Each 25-854 31043


Same as Item 25-853, But up to 300 Amps. Each 25-855 41652
Same as Item 25-853, But up to 400 Amps. Each 25-856 41723
Same as Item 25-853, But up to 500 Amps. Each 25-857 47309
Same as Item 25-853, But up to 750 Amps. Each 25-858 125106
Same as Item 25-853, But up to 1000 Amps. Each 25-859 140038
Same as Item 25-853, But up to 1200 Amps. Each 25-860 149034
Same as item 25-853 to 25-854 but fixing only. Each 25-861 2925
Same as item 25-855 to 25-857 but fixing only. Each 25-862 3525
Same as item 25-858 to 25-859 but fixing only. Each 25-863 6204
Add to item 25-853 to 25-854 or 25-861 and if removal only. Each 25-864 1463

Add to item 25-855 to 25-857 or 25-862 if removal only. Each 25-865 2291

Add to item 25-858 to 25-859 or 25-863 if removal only. 25-866 4653

Voltage Regulator
Auto Voltage Regulator (AVR), AC 380-400/220-230 V, 3 Each 25-867 1960486
phase,
50 cycles, suitable for un-balanced load, capable of delivering
steady output voltage upto variation of + 1%, complete with
voltmeter and selection switch, pilot lamps and
potentiometer, capacity 30 KVA with upto + 20% variation on
input voltage, (EU Origin ), supply and fixing.

Same as item 25-867, but 72 KVA. Each 25-868 3594250


Same as item 25-867, but 100 KVA. Each 25-869 4974697
Same as item 25-867, but 150 KVA. Each 25-870 6122748
Same as item 25-867, but 220 KVA. Each 25-871 7037038
Same as item 25-867, but 300 KVA. Each 25-872 8390047
Same as item 25-867, but 450 KVA. Each 25-873 10096538
Same as item 25-867 to 25-868, but fixing only. Each 25-874 2046
Same as item 25-869 to 25-871, but fixing only. Each 25-875 3274
Same as item 25-872 to 25-873, but fixing only. Each 25-876 5640
Add to item 25-867 to 25-868 or 25-874 if removal only. Each 25-877 1432

Add to item 25-869 to 25-871 or 25-875 if removal only. Each 25-878 2292

Add to item 25-872 to 25-873 or 25-876 if removal only. Each 25-879 3948

Voltage Regulator
Auto Voltage Regulator (AVR) Servo Control Type, Input 3 Each 25-880 226174
Phase + neutral 380 VAC, Input voltage range ±25% (from
285 V, AC~475 VAC), output voltage, 3 phase, 380 V, AC, rms
stabilized, output voltage accuracy ±1~2%, frequency
50/60 Hz, 5% admitted load variation 0-100%, admitted load
unbalance upto 100%, correction speed 12ms/v, wave form
distortion, <1%, max failure range, <±1%, efficiency, >98%,
cooling, air cooled with fan, operating temperature -10ºC to
+60ºC, relative humidity not more than 90%, storage
temperature -20ºC to +60ºC, over load 200% for 02 Sec,
distortion less than 01%, power factor 0.8, Instrumentation
input & output complete with volt and amp meters with
selection switches, suitable rated input / output terminal
blocks / busbars, all standard protections at input & output
MCCBs (Eu Brand), paint colour light Grey (RAL 7035),
capacity 10 KVA, (Pak Made ), Supply and Fixing.

Same as item 25-880 but 15 KVA. Each 25-881 338494


Same as item 25-880 but 20 KVA. Each 25-882 415714
Same as item 25-880 but 30 KVA. Each 25-883 672846
Same as item 25-880 but 50 KVA. Each 25-884 928686
Same as item 25-880 but 72 KVA. Each 25-885 1249710
Same as item 25-880, but 100 KVA. Each 25-886 1572142
Same as item 25-880, but 150 KVA. Each 25-887 2259108
Same as item 25-880, but 220 KVA. Each 25-888 3197738
Same as item 25-880, but 300 KVA. Each 25-889 4181462
Same as item 25-880, but 400 KVA. Each 25-890 5587592
Same as item 25-880 to 25-882 but fixing only. Each 25-891 1535
Same as item 25-883 to 25-885 but fixing only. Each 25-892 2046
Same as item 25-886 to 25-888 but fixing only. Each 25-893 3274
Same as item 25-889 to 25-890 but fixing only. Each 25-894 5640
Add to item 25-880 to 25-882 or 25-891 if removal only. Each 25-895 1074

Add to item 25-883 to 25-885 or 25-892 if removal only. Each 25-896 1432

Add to item 25-886 to 25-888 or 25-893 if removal only. Each 25-897 2292

Add to item 25-889 to 25-890 or 25-894 if removal only. Each 25-898 3948

Road / Street Lights


Bracket for Road/Street/External light (MS/GI pipe), supply Each 25-899 2059
and fixing.
Same as item 25-899, but fixing only. Each 25-900 246
Add to item 25-899 or 25-900, if removal only. Each 25-901 172
Earth for Transformers
Special Earth for transformers, HT and LT, switchgear for Each 25-902 19039
areas having water table upto 3M depth, supply and fixing
vide Para 25.4 of Specifications.
Same as item 25-902, but for areas having water table more Each 25-903 22752
than 3 M depth, supply and fixing only.
Same as item 25-902, but for areas having water table more Each 25-904 53414
than 6 M upto 12 M depth, supply and fixing only.

Same as item 25-902 to 25-904, but fixing only. Each 25-905 7620
Add to item 25-902 to 25-905, if removal only. Each 25-906 930
VCBs
Vacuum Circuit Breaker (VCB), HT 11 KV, panel floor Each 25-907 1697208
mounting, 400/630 A, rating 25 KA, 17.5 KV complete with
selector switches, indicating lamps, spring Charging motor
220 V AC, 50ms DC closing coil 110 V DC, 50ms DC Trip Coil
110 V, CT, PT, Earth fault, over current, short circuit, current
digital relay, frequency meter, amp meter, volt meter,
capacitor trip unit, MCB 06 A, SP, charging handle, push
button, mounted in sheet steel cubicle, factory assembled
duly painted, single panel unit complete with energy meter,
MDI & KVARH complete in all respect.

Same as item 25-907 but one incoming and two outgoing (set Each 25-908 5066808
of three).
Same as item 25-907, but two incoming and one outgoing Each 25-909 5066808
(set of three) including all protections and arrangement for
incoming supply sources and locking device system, electrical
and mechanical interlocking as per manufacturer's
specifications.
Same as item 25-907 to 25-909, but fixing only. Each 25-910 12408
Add to item 25-907 to 25-909 or 25-910, if removal only. Each 25-911 5729

KWH + MDI and KVARH combined meter HT Panel, supply Each 25-912 72060
and fixing.
Same as item 25-912 but fixing only. Each 25-913 1860
Add to item 25-912 or 25-913 if removal only. Each 25-914 1395
Feeder Pillar Cabin, size 600 x 450 x 900 mm, made of steel Each 25-915 57204
sheet (14 BG) and angle iron frame size 38 x 38 mm, with
water resistance, hinged cover having locking arrangement,
duly painted of approved quality, consisting of hard drawn
insulated copper bus-bars 4 nos, capacity 800 -1000 A,
mounted on good quality porcelain base/cleats with brass nut
/ bolts off sizes, drilled holes of appropriate size for inlets and
outlets cables, earthing jointing system, foundation of PCC
1:2:4 and suitable arrangement for breakers incoming and
out-going, (excluding cost of breaker) , supply and fixing.

Same as item 25-915, but 400 - 600 A. Each 25-916 48,001.00


Same as item 25-915, but 200 - 300 A. Each 25-917 43,789.00
Same as item 25-915 to 25-917, but fixing only. Each 25-918 686.00
Add to item 25-915 to 25-917 or 25-918, if removal only. Each 25-919 259.00

PG Clamp
PG Clamp 25 mm size, Aluminium with proper GI nuts, bolts Each 25-920 183
and spring washer, Supply & Fixing.
Same as Item 25-920, but 50 mm. Each 25-921 247
Same as Item 25-921, but 75 mm. Each 25-922 531
PG Clamp 25 mm size Bimetal copper/Aluminium for jointing Each 25-923 987
of copper cable with Aluminium conductor or Aluminium
cable with copper, conductor of proper GI nuts, bolts and
spring washer, Supply & Fixing.
Same as Item 25-923 but 50 mm. Each 25-924 1280
Same as Item 25-923 but 75 mm. Each 25-925 1933
Same as Item 25-920 or 25-923 but fixing. Each 25-926 86
Same as Item 25-921 to 25-924 but fixing. Each 25-927 104
Same as Item 25-922 or 25-925 but fixing. Each 25-928 121
Add to item 25-920 to 25-928 if removal only. Each 25-929 86
Bus Tie Ducts
Bus Tie Ducts Copper, 1000 A, TP & N Made out of 14 SWG Metre 25-930 44414
M.S Sheet Steel painted with electro static powder coated
paint RAL-7032 Complete in all respect, supply and fixing.

Same as item 25-930 but 1250 A, TP & N. Metre 25-931 59439


Same as item 25-930 but 1600 A, TP & N. Metre 25-932 70824
Same as item 25-930 but 2000 A, TP & N. Metre 25-933 109108
Same as item 25-930 but 2500 A, TP & N. Metre 25-934 132544
Same as item 25-930 but 3200 A, TP & N. Metre 25-935 174698
Same as item 25-930, 25-933, but fixing only. Metre 25-936 465
Same as item 25-934, 25-935, but fixing only. Metre 25-937 698
Add to item 25-930 to 25-933 or 25-936 if removal only. Metre 25-938 349

Add to item 25-934 to 25-935 or 25-937 if removal only. Metre 25-939 512

ATS Panels
ATS Panel 10 KVA, ATP & N, Made out of 14 SWG M.S Sheet Each 25-940 96748
Steel painted with electro static powder coated (paint RAL-
7032ATS), Panel Complete in all respect. Supply & Fixing.

Same as item 25-940 but 15 KVA, ATS Panels. Each 25-941 100287
Same as item 25-940 but 20 KVA, ATS Panels. Each 25-942 105341
Same as item 29-940 but 30 KVA, ATS Panels. Each 25-943 116801
Same as item 25-940 but 40 KVA, ATS Panels. Each 25-944 124949
Same as item 25-940 but 50 KVA, ATS Panels. Each 25-945 139832
Same as item 25-940 but 60 KVA, ATS Panels Each 25-946 150221
Same as item 25-940 but 75 KVA, ATS Panels. Each 25-947 164658
Same as item 25-940 but 100 KVA, ATS Panels. Each 25-948 178137
Same as item 25-940 but 125 KVA, ATS Panels. Each 25-949 275208
Same as item 25-940 but 150 KVA, ATS Panels. Each 25-950 311548
Same as item 25-940 but 175 KVA, ATS Panels. Each 25-951 339628
Same as item 25-940 but 200 KVA, ATS Panels. Each 25-952 436644
Same as item 25-940 but 250 KVA, ATS Panels. Each 25-953 490229
Same as item 25-940 but 300 KVA, ATS Panels. Each 25-954 541163
Same as item 25-940 but 400 KVA, ATS Panels. Each 25-955 781163
Same as item 25-940 but 500 KVA, ATS Panels. Each 25-956 1802025
Same as item 25-940 but 600 KVA, ATS Panels. Each 25-957 1922025
Same as item 25-940 but 700 KVA, ATS Panels. Each 25-958 1955161
Same as item 25-940 to 25-943, but fixing only. Each 25-959 465
Same as item 25-944 to 25-946, but fixing only. Each 25-960 698
Same as item 25-947 to 25-949, but fixing only. Each 25-961 814
Same as item 25-950 to 25-952, but fixing only. Each 25-962 930
Same as item 25-953 to 25-955, but fixing only. Each 25-963 1162
Same as item 25-956 to 25-958, but fixing only. Each 25-964 2025
Add to item 25-940 to 25-943 or 25-959 if removal only. Each 25-965 349
Add to item 25-944 to 25-946 or 25-960 if removal only. Each 25-966 523

Add to item 25-947 to 25-949 or 25-961 if removal only. Each 25-967 608

Add to item 25-950 to 25-952 or 25-962 if removal only. Each 25-968 697

Add to item 25-953 to 25-955 or 25-963 if removal only. Each 25-969 870

Add to item 25-956 to 25-958 or 25-964 if removal only. Each 25-970 1418

CABLE TRAY
Cable tray out of 16 Guage, GI sheet, without cover, Metre 25-971 923
complete in jointing plates. Cable tray size 4” x 2”.
Same as item 25-971 but Cable tray size 6” x 2”. Metre 25-972 1071
Same as item 25-971 but Cable tray size 9” x 2”. Metre 25-973 1300
Same as item 25-971 but Cable tray size 12” x3”. Metre 25-974 1797
Same as item 25-971 but Cable tray size 15” x 3”. Metre 25-975 2027
Same as item 25-971 but Cable tray size 18” x 4”. Metre 25-976 2524
Same as item 25-971 but Cable tray size 24” x 4”. Metre 25-977 2981
Same as item 25-971 to 25-973, but fixing only. Metre 25-978 233
Same as item 25-974 to 25-975, but fixing only. Metre 25-979 349
Same as item 25-976 to 25-977, but fixing only. Metre 25-980 465
Add to item 25-971 to 25-973 or 25-978, but fixing only. Metre 25-981 140

Add to item 25-974 to 25-975 or 25-978, but fixing only. Metre 25-982 233

Add to item 25-976 to 25-977 or 25-980, but fixing only. Metre 25-983 349

Street Light
LED Road Street Light, 22 Watts, 220-240 Volts, “Standard”, Each 25-984 4428
complete supply and fixing.
Same as item 25-984 but Deluxe. Each 25-985 8928
Same as item 25-984 but Premium. Each 25-986 15948
Same as item 25-984 but 27 watt Standard. Each 25-987 5628
Same as item 25-987 but Deluxe. Each 25-988 9348
Same as item 25-987 but Premium. Each 25-989 17028
Same as item 25-984 but 50 watt Standard. Each 25-990 6828
Same as item 25-990 but Deluxe. Each 25-991 12768
Same as item 25-990 but Premium. Each 25-992 24228
Same as item 25-984 but 60 watt Standard. Each 25-993 11628
Same as item 25-993 but Deluxe. Each 25-994 13128
Same as item 25-993 but Premium. Each 25-995 19048
Same as item 25-984 but 70 watt Standard. Each 25-996 10428
Same as item 25-996 but Deluxe. Each 25-997 21228
Same as item 25-996 but Premium. Each 25-998 35428
Same as item 25-984 but 90 watt Standard. Each 25-999 13428
Same as item 25-999 but Deluxe. Each 25-1000 24892
Same as item 25-999 but Premium. Each 25-1001 36427
Same as item 25-984 but 100 & 110 watt Standard. Each 25-1002 31428
Same as item 25-1002 but Deluxe. Each 25-1003 32628
Same as item 25-1002 but Premium. Each 25-1004 44328
Same as item 25-984 but 120 & 130 watt Standard. Each 25-1005 21978
Same as item 25-1005 but Deluxe. Each 25-1006 34128
Same as item 25-1005 but Premium. Each 25-1007 41910
Same as item 25-984 but 140 & 150 watt Standard. Each 25-1008 25728
Same as item 25-1008 but Deluxe. Each 25-1009 38328
Same as item 25-1008 but Premium. Each 25-1010 56148
Same as item 25-984 but 160 & 170 watt Standard. Each 25-1011 27228
Same as item 25-1011 but Deluxe. Each 25-1012 43428
Same as item 25-1011 but Premium. Each 25-1013 66648
Same as item 25-984 but 180 watt Standard. Each 25-1014 38328
Same as item 25-1014 but Deluxe. Each 25-1015 38388
Same as item 25-1014 but Premium. Each 25-1016 67038
Same as item 25-984 to 25-1016 but fixing only. Each 25-1017 960
Add to item 25-984 to 25-1016 or 25-1017 if removal only. Each 25-1018 518

Flood Light
LED Flood Security Light, 30 Watts, 220-240 Volts, approved Each 25-1019 4118
type “Standard”, complete supply and fixing.
Same as item 25-1019 but Deluxe. Each 25-1020 5001
Same as item 25-1019 but Premium. Each 25-1021 15841
Same as item 25-1019 but 50 watt Standard. Each 25-1022 5541
Same as item 25-1022 but Deluxe. Each 25-1023 7261
Same as item 25-1022 but Premium. Each 25-1024 23271
Same as item 25-1019 but 70 watt Standard. Each 25-1025 10221
Same as item 25-1025 but Deluxe. Each 25-1026 12381
Same as item 25-1025 but Premium. Each 25-1027 24021
Same as item 25-1019 but 100 & 110 watt Standard. Each 25-1028 11142
Same as item 25-1028 but Deluxe. Each 25-1029 22322
Same as item 25-1028 but Premium. Each 25-1030 36473
Same as item 25-1019 but 120 watt Standard. Each 25-1031 12622
Same as item 25-1031 but Deluxe. Each 25-1032 20422
Same as item 25-1031 but Premium. Each 25-1033 27022
Same as item 25-1019 but 160 watt Standard. Each 25-1034 16822
Same as item 25-1034 but Deluxe. Each 25-1035 21782
Same as item 25-1034 but Premium. Each 25-1036 34222
Same as item 25-1019 but 200 watt Standard. Each 25-1037 18022
Same as item 25-1037 but Deluxe. Each 25-1038 28622
Same as item 25-1037 but Premium. Each 25-1039 45622
Same as item 25-1019 but 220 watt Standard. Each 25-1040 29422
Same as item 25-1040 but Deluxe. Each 25-1041 48022
Same as item 25-1040 but Premium. Each 25-1042 68422
Same as item 25-1019 but 245 watt Standard. Each 25-1043 45622
Same as item 25-1043 but Deluxe. Each 25-1044 63022
Same as item 25-1043 but Premium. Each 25-1045 91582
Same as item 25-1019 but 315 watt Standard. Each 25-1046 55822
Same as item 25-1046 but Deluxe. Each 25-1047 64222
Same as item 25-1046 but Premium. Each 25-1048 66022
Same as item 25-1019 but 350 watt Standard. Each 25-1049 66622
Same as item 25-1049 but Deluxe. Each 25-1050 72022
Same as item 25-1049 but Premium. Each 25-1051 78622
High Bay Light LED, 100 watt, stiff pendent 220-240 Volts, Each 25-1052 22582
approved type, ceiling mounted round type “Standard”,
complete supply and fixing.
Same as item 25-1052 but Deluxe. Each 25-1053 26062
Same as item 25-1052 but Premium. Each 25-1054 31702
Same as item 25-1052 but 150 watt Standard. Each 25-1055 22462
Same as item 25-1055 but Deluxe. Each 25-1056 42622
Same as item 25-1055 but Premium. Each 25-1057 43054
Same as item 25-1019 to 25-1057 but fixing only. Each 25-1058 388
Add to item 25-1019 to 25-1057 or 25-1058 if removal only. Each 25-1059 388

Description Unit SI No. Rate (Rs)


Sui Gas - Pipe Work
M.S Pipe for high pressure, including cleaning, applying Metre 26-1 823
primer, coating with BBES (Bitumen Binding Enamel Surface)
compound and wrapping with fibre glass, welding, complete
20 mm dia, laid in trenches (excluding excavation), supply
and fixing.
Same as item 26-1, but 25 mm dia. Metre 26-2 1080
Same as item 26-1, but 50 mm dia. Metre 26-3 1454
Same as item 26-1, but 100 mm dia, double wrapping with Metre 26-4 3300
fiber glass
Same as item 26-4, but 150 mm dia. Metre 26-5 4685
Same as item 26-1, but fixing only. Metre 26-6 203
Same as item 26-2, but fixing only. Metre 26-7 225
Same as item 26-3, but fixing only. Metre 26-8 248
Same as item 26-4, but fixing only. Metre 26-9 270
Same as item 26-5, but fixing only. Metre 26-10 293
Add to item 26-1 or 26-6, if removal only. Metre 26-11 152
Add to item 26-2 or 26-7, if removal only. Metre 26-12 169
Add to item 26-3 or 26-8, if removal only. Metre 26-13 186
Add to item 26-4 or 26-9, if removal only. Metre 26-14 203
Add to item 26-5 or 26-10, if removal only. Metre 26-15 219
Gas Valves / Cocks
Eclipse valve 20 mm dia, supply and fixing. Each 26-16 1094
Same as item 26-16, but 25 mm dia. Each 26-17 2568
Same as item 26-16, but fixing only. Each 26-18 41
Same as item 26-17, but fixing only. Each 26-19 48
Add to item 26-16 or 26-18, if removal only. Each 26-20 31
Add to item 26-17 or 26-19, if removal only. Each 26-21 36
Audco Valve, 20mm dia, supply and fixing. Each 26-22 1174
Same as item 26-22, but 25 mm dia. Each 26-23 1803
Same as item 26-22, but 50 mm dia. Each 26-24 6394
Same as item 26-22, but fixing only. Each 26-25 41
Same as item 26-23, but fixing only. Each 26-26 48
Same as item 26-24, but fixing only. Each 26-27 76
Add to item 26-22 or 26-25, if removal only. Each 26-28 31
Add to item 26-23 or 26-26, if removal only. Each 26-29 36
Add to item 26-24 or 26-27, if removal only. Each 26-30 57
Brass cock, Union type, gas quality, 15 mm dia, supply and Each 26-31 484
fixing.
Same as item 26-31, but 20 mm dia. Each 26-32 821
Same as item 26-31, but 25 mm dia. Each 26-33 1068
Same as item 26-31, but fixing only. Each 26-34 35
Same as item 26-32, but fixing only. Each 26-35 41
Same as item 26-33, but fixing only. Each 26-36 48
Add to item 26-31 or 26-34, if removal only. Each 26-37 26
Add to item 26-32 or 26-35, if removal only. Each 26-38 31
Add to item 26-33 or 26-36, if removal only. Each 26-39 36
Brass valve, ball type screwed both ends complete with steel Each 26-40 443
handle, washer/ nut 15 mm dia, supply and fixing.
Same as item 26-40, but 20 mm dia. Each 26-41 515
Same as item 26- 40, but 25 mm dia. Each 26-42 708
Same as item 26- 40, but 40 mm dia. Each 26-43 2119
Same as item 26- 40, but 50 mm dia. Each 26-44 2916
Same as item 26- 40, but 65 mm dia. Each 26-45 6584
Same as item 26-40, but fixing only. Each 26-46 35
Same as item 26-41, but fixing only. Each 26-47 41
Same as item 26-42, but fixing only. Each 26-48 48
Same as item 26-43, but fixing only. Each 26-49 69
Same as item 26-44, but fixing only. Each 26-50 86
Same as item 26-45, but fixing only. Each 26-51 104
Add to item 26-40 or 26-46, if removal only. Each 26-52 26
Add to item 26-41 or 26-47, if removal only. Each 26-53 31
Add to item 26-42 or 26-48, if removal only. Each 26-54 36
Add to item 26-43 or 26-49, if removal only. Each 26-55 52
Add to item 26-44 or 26-50, if removal only. Each 26-56 69
Add to item 26-45 or 26-51, if removal only. Each 26-57 86
Tandoor Burner
Tandoor burner (48 nozzles), complete with burner plate, Each 26-58 5798
regulator /manifold etc., supply and fixing.
Same as item 26-58, but fixing only. Each 26-59 518
Add to item 26-58 or 26-59, if removal only. Each 26-60 388
Plate for 48 nozzles Tandoor burner, supply and fixing. Each 26-61 2573
Same as item 26-61, but fixing only. Each 26-62 259
Add to item 26-61 or 26-62, if removal only. Each 26-63 194
Gas Water Heater
Gas water heater of 12 SWG Black Sheet (Inner tank), Each 26-64 20318
complete with burner pilot, thermostat and safety valve, 68
lit capacity, supply and fixing.
Same as item 26-64, but 136 lit capacity of 10 SWG Black Each 26-65 27758
Sheet (Inner tank).
Same as item 26-64, but 225 lit capacity of 10SWG Black Each 26-66 32280
sheet (inner tank).
Same as item 26-64, but 455 lit capacity of 10SWG Black Each 26-67 105990
sheet (inner tank).
Dual action Gas cum electric water heater of 12 SWG Black Each 26-68 28769
Sheet (Inner tank), complete with burner pilot, thermostat
and safety valve, with Electric Element & Electric thermostat
68 lit capacity, supply and fixing.
Same as item 26-64, but 136 lit capacity of 10 SWG Black Each 26-69 32303
Sheet (Inner tank).
Same as item 26-64, but 225 lit capacity of 10 SWG Black Each 26-70 36315
sheet (inner tank).
Same as item 26-64 to 26-65, 24-68, 24-69 but fixing only. Each 26-71 518

Same as item 26-66 to 26-67, 24-70, but fixing only. Each 26-72 690
Add to item 26-64 to 26-65 or 26-71, if removal only. Each 26-73 388
Add to item 26-66 to 26-67 or 26-72, if removal only. Each 26-74 518
Instant Gas water heater, complete with burner pilot, Ignition Each 26-75 11625
coil Operated DC 1.5 Volt Battery and safety valve, 6 lit per
min capacity, supply and fixing.
Same as item 26-75, but 8 lit per min. Each 26-76 15225
Same as item 26-75, but 10 lit per min. Each 26-77 17145
Same as item 26-75 to 26-77, but fixing only. Each 26-78 345
Add to item 26-75 to 26-77 or 26-78 if removal only. Each 26-79 259
Gas light best quality approved type supply and fixing. Each 26-80 753
Same as item 26-80, but fixing only. Each 26-81 86
Add to item 26-80 or 26-81 if removal only. Each 26-82 52
Gas Room Heater
Gas room heater of 20 SWG Black Sheet, complete with pilot, Each 26-83 6632
single burner, supply and fixing.
Gas room heater of 20SWG Black Sheet, complete with pilot, Each 26-84 8005
double burner, supply and fixing.
Same as item 26-83 to 26-84, but fixing only. Each 26-85 518
Add to item 26-83 to 26-85, if removal only. Each 26-86 388
Gas Burner (Chullah)
Gas burner (Chullah) of 20 SWG Black Sheet, single burner, Each 26-87 2257
supply and fixing.
Same as item 26-87, but double burner. Each 26-88 3638
Build in burner non Magnetic steel top, one Large super Each 26-89 18734
prime burner and 4 medium burner, non-stick paint coated,
auto ignition 3, volt battery operated, supply and fixing.

Same as item 26-89, but Glass Top. Each 26-90 19706


Build in burner non Magnetic Stainless steel Glass, 2 Large 26-91 13838
super prime burner and 1 medium burner, non stick paint
coated, auto ignition 3 volt battery operated, supply and
fixing.
Build in burner non Magnetic Stainless steel Glass, 2 Large Each 26-92 11030
super prime burner, non stick paint coated auto ignition 3
volt battery operated supply and fixing.
Same as item 26-87 to 26-92, but fixing only. Each 26-93 518
Add to item 26-87 to 26-93, if removal only. Each 26-94 403
Gas Cooking Range
Gas cooking range of 20 SWG Black Sheet, two burner 27, Each 26-95 20318
single door, complete with thermostat, oven, grill, rotisserie
and tempered (heat-proof) crystal glass, supply and fixing.

Same as item 26-95, but 34”, 3 burner, double door. Each 26-96 23678
Same as item 26-95, but 34”, 5 burner single door. Each 26-97 30704
Same as item 26-95, but 5 burners double door. Each 26-98 31958
Same as item 26-95, to 26-98, but fixing only. Each 26-99 518
Add to item 26-9 to 26-96, if removal only. Each 26-100 388
Micro hose (Fire resistant) 3 feet, long complete with brass Each 26-101 3773
coupling on both end supply & fixing.
Same as item 26-101 but 4 feet long. Each 26-102 4973
Same as item 26-101 but 6 feet long. Each 26-103 7373
Same as Item 26-101 to 26-102 but fixing only. Each 26-104 173
Add to Item 26-101 to 26-102 or 26-103 if removal only. Each 26-105 138

Miscellaneous
Thermostat of gas water heater complete with thermocouple Each 26-106 2678
wire and pilot tube, supply and fixing.
Same as item 26-106, but fixing only. Each 26-107 518
Add to item 26-106 or 26-107, if removal only. Each 26-108 388
Audco valve, high pressure, MW-13 type, 100 mm dia flanged Each 26-109 12696
with nuts and bolts, complete, supply and fixing.

Same as item 26-109, but 150 mm dia. Each 26-110 30282


Same as item 26-109 to 26-110, but fixing only. Each 26-111 690
Add to item 26-109 to 26-110 or 26-111, if removal only. Each 26-112 518

Muller Tee 20 mm dia welded, supply and fixing. Each 26-113 720
Same as item 26-113, but 25 mm dia. Each 26-114 1536
Same as item 26-113, but 50 mm dia. Each 26-115 3582
Same as item 26-113 or 26-114, but fixing only. Each 26-116 150
Same as item 26-115, but fixing only. Each 26-117 244
Add to item 26-113 to 26-117, if removal only. Each 26-118 112
Sui gas regulator, “Peeble type”, domestic, supply and fixing. Each 26-119 1119

Same as item 26-119, but 043 type. Each 26-120 2079


Same as item 26-119 to 26-120, but fixing only. Each 26-121 759
Add to item 26-119 to 26-120 or 26-121, if removal only. Each 26-122 569

Sui Gas Meter


Sui gas Meter, domestic, with brass coupling, supply and Each 26-123 6279
fixing.
Sui gas Meter, commercial, complete with brass coupling, Each 26-124 20559
supply and fixing.
Same as item 26-123 to 26-124, but fixing only. Each 26-125 759
Add to item 26-123 to 26-124 or 26-125, if removal only. Each 26-126 569

Gas Heater, flue pipe assembly, fabricated with 24 gauge, GI Each 26-127 360
sheet, supply and fixing.
Same as item 26-127, but fixing only. Each 26-128 61
Add to item 26-127 to 26-128, if removal only. Each 26-129 46
Locking cock brass, 20 mm dia, gas quality, supply and fixing. Each 26-130 691

Same as item 26-130, but fixing only. Each 26-131 76


Add to item 26-130 or 26-131, if removal only. Each 26-132 57
Poly Ethylene (PE) Gas Pipe
Poly Ethylene (PE) Gas Pipe, Class MDPE-80, Yellow pipe (SDR- Metre 26-133 149
11) 20mm dia, without Butt Fusion joint, (excluding cost of
excavation), supply and fixing.
Same as item 26-133, but 25 mm dia. Metre 26-134 199
Same as item 26-133, but 40 mm dia. Metre 26-135 309
Same as item 26-133, but 50 mm dia. Metre 26-136 505
Same as item 26-133, but 75 mm dia. Metre 26-137 1166
Same as item 26-133, but 100 mm dia. Metre 26-138 1691
Same as item 26-133, but 160 mm dia. Metre 26-139 3476
Same as item 26-133, 26-134, but fixing only. Metre 26-140 69
Same as item 26-135 to 26-137, but fixing only. Metre 26-141 86
Same as item 26-138, 26-139, but fixing only. Metre 26-142 173
Add to item 26-133 to 26-134 or 26-140 if removal only. Metre 26-143 52

Add to item 26-135 to 26-137 or 26-141 if removal only. Metre 26-144 65

Add to item 26-138 to 26-139 or 26-142 if removal only. Metre 26-145 129

Fitting
Butt Fusion joint, for pipe 20 mm dia, joint complete as Each 26-146 960
specified.
Same as item 26-146 but for pipe 25 mm dia. Each 26-147 960
Same as item 26-146 but for pipe 40 mm dia. Each 26-148 960
Same as item 26-146 but for pipe 50 mm or 75 mm dia. Each 26-149 1200

Same as item 26-146 but for pipe 100 mm dia. Each 26-150 1800
Same as item 26-146 but for pipe 160 mm dia. Each 26-151 1800
Elbow 20 mm for gas pipe MDPE 80, supply and fixing. Each 26-152 226
Same as item 26-152 but 25 mm dia. Each 26-153 635
Same as item 26-152 but 40 mm or 50 mm dia. Each 26-154 850
Same as item 26-152, but 75 mm dia. Each 26-155 4684
Same as item 26-152, but 100 mm dia. Each 26-156 6086
Same as item 26-152, but 160 mm dia. Each 26-157 20907
Cap, 20 mm or 25 mm dia, supply and fixing. Each 26-158 455
Same as item 26-158, but 40 mm to 50 mm dia. Each 26-159 635
Same as item 26-158, but 75 mm to 100 mm dia. Each 26-160 4269
Same as item 26-158, but 160 mm dia. Each 26-161 11966
Tee, 20mm or 25mm dia, supply and fixing. Each 26-162 370
Same as item 26-162, but 40 mm or 50 mm dia. Each 26-163 1269
Same as item 26-62, but 75 mm or 100 mm dia. Each 26-164 4702
Same as item 26-162 but 160 mm dia. Each 26-165 6753
Tapping Tee, Reducing, 25 x 20 mm or 50 x 20 mm dia, Each 26-166 1269
supply and fixing.
Same as item 26-166, but 100 x 20 mm dia. Each 26-167 4291
Same as item 26-166, but 100 x 25 mm dia. Each 26-168 5420
Same as item 26-166, but 100 x 50 mm dia. Each 26-169 5745
Same as item 26-166, but 160 x 25 mm dia. Each 26-170 5898
Same as item 26-166, but160 x 50 mm dia. Each 26-171 6001
Same as item 26-152, 26-153, 26-158 or 26-159, but fixing Each 26-172 35
only.
Same as item 26-154, 26-155, 26-160 to 26-163 or 26-166, Each 26-173 69
but fixing only.
Same as item 26-156, 26-157, 26-164, 26-165, 26-167 or 26- Each 26-174 86
168, but fixing only.
Same as item 26-169 to 26-171, but fixing only. Each 26-175 104
Add to item 26-152, 26-153, 26-158, 26-159 or 26-172, if Each 26-176 26
removal only.
Add to item 26-154, 26-155, 26-160 to 26-163, 26-166 or 26- Each 26-177 52
173, if removal only.
Add to item 26-156, 26-157, 26-164, 26-165, 26-167 or 26- Each 26-178 65
168 or 26-173, if removal only.
Add to item 26-169 to 26-171or 26-174, if removal only. Each 26-179 78

Multi Gas Detector with Control System to detect gas leakage Each 26-180 36414
and automatically shut down gas supply, Provision & fixing.

Non Industrial at home usage Natural Gas (Methane) Each 26-181 20350
Detector with LCD Display Alarm, Supply & Fixing.
Sensitive Gas Detector, plug in with LCD Display and alarm, Each 26-182 2920
supply and fixing.
Same as Item 26-180 to 26-182 but fixing only. Each 26-183 144
Add to item 26-180 to 26-182 if removal only. Each 26-184 72

Description Unit SI No. Rate (Rs)


Ducting
GI Sheet metal ducting, complete with hangers for ceiling Sqm 27-1 2597
suspended, proper support for duct running on roof and
bracing complete in all respect 26 SWG supply and fixing.

Same as Item 27-1, but 24 SWG. Sqm 27-2 2778


Same as Item 27-1, but 22 SWG. Sqm 27-3 3010
Same as Item 27-1, but 20 SWG. Sqm 27-4 3449
Same as Item 27-1, but 18 SWG. Sqm 27-5 3791
Same as Item 27-1, but fixing only. Sqm 27-6 705
Same as Item 27-2, but fixing only. Sqm 27-7 705
Same as Item 27-3, but fixing only. Sqm 27-8 705
Same as Item 27-4, but fixing only. Sqm 27-9 904
Same as Item 27-5, but fixing only. Sqm 27-10 904
Added to Item 27-1 or 27-6, if removal only. Sqm 27-11 404
Add to Item 27-2 or 27-7, if removal only. Sqm 27-12 404
Add to Item 27-3 or 27-8, if removal only. Sqm 27-13 404
Add to item 27-4 or 27-9, if removal only. Sqm 27-14 489
Add to item 27-5 or 27-10, if removal only. Sqm 27-15 489
Insulation
Fibre glass or rock wool insulation, for GI duct, 1 inch thick, Sqm 27-16 1482
supply and fixing.
Same as item 27-16, but 1.5 inch thickness. Sqm 27-17 1648
Vapour barrier for GI duct, consist of 2 ply Kraft foil, with Sqm 27-18 4407
internal fibre glass yarn reinforcement at maximum 1 inch
centre to centre.
External covering for GI duct, consist of coarse cloth covering. Sqm 27-19 260

Sound liner thickness 1 inch, for GI duct where required, Sqm 27-20 16350
supply and fixing.
Same as item 27-20, but 2 inch thickness. Sqm 27-21 28774
Same as item 27-16, but fixing only. Sqm 27-22 930
Same as item 27-17, but fixing only. Sqm 27-23 930
Same as item 27-18, but fixing only. Sqm 27-24 207
Same as item 27-19, but fixing only. Sqm 27-25 207
Same as item 27-20, but fixing only. Sqm 27-26 1350
Same as item 27-21, but fixing only. Sqm 27-27 1800
Added to item 27-16 or 27-22, if removal only. Sqm 27-28 698
Added to item 27-17 or 27-23, if removal only. Sqm 27-29 698
Added to item 27-18 or 27-24, if removal only. Sqm 27-30 155
Added to item 27-19 or 27-25, if removal only. Sqm 27-31 155
Added to item 27-20 or27-26, if removal only. Sqm 27-32 1013
Added to item 27-21 or 27-27, if removal only. Sqm 27-33 1013
Supply/ Returns Exhaust Air Diffusers
Supply air diffusers, supply and fixing. Sqm 27-34 21702
Return air diffusers, supply and fixing. Sqm 27-35 21702
Return air grill, supply and fixing. Sqm 27-36 20112
Exhaust air diffusers, supply and fixing. Sqm 27-37 21702
Same as item 27-34 to 27-37, but fixing only. Sqm 27-38 1035
Add to item 27-34 to 27-37 or 27-38, if removal only. Sqm 27-39 776
Balancing Valve for chilled/hot water, 25mm dia (KITZ Japan) Each 27-40 7279
supply and fixing.
Same as Item 27-40, but 32mm dia. Each 27-41 7758
Same as Item 27-40, but 40mm dia. Each 27-42 9678
Same as Item 27-40, but 50mm dia. Each 27-43 11958
Same as Item 27-40, but 65mm dia. Each 27-44 16878
Same as Item 27-40, but flanged and drilled BS Table 18-1-9 Each 27-45 23987
75mm dia.
Same as Item 27-45, but 100mm dia. Each 27-46 41168
Same as Item 27-45, but 125mm dia. Each 27-47 59967
Same as Item 27-45, but 150mm dia. Each 27-48 94767
Same as Item 27-45, but 200mm dia. Each 27-49 142767
Non-Return Valve screwed 75mm dia, (Kitz Japan) flanged Each 27-50 11852
and drilled B.S Table 18-1-9.
Same as Item 27-50, but 100mm dia. Each 27-51 15848
Same as Item 27-50, but 125mm dia. Each 27-52 19532
Same as Item 27-50, but 150mm dia. Each 27-53 21453
Same as Item 27-50, but 200mm dia. Each 27-54 34053
Y Strainer 75mm dia (Kitz Japan), flanged and drilled, B.S Each 27-55 11132
Table 18-1-9 supply and fixing.
Same as Item 27-55, but 100mm dia. Each 27-56 14648
Same as Item 27-55, but 125mm dia. Each 27-57 18368
Same as Item 27-55, but 150mm dia. Each 27-58 22053
Same as Item 27-55, but 200mm dia. Each 27-59 34053
Automatic Air Vent Valve, 20mm dia (Kitz Japan) supply and Each 27-60 1818
fixing.
Same as Item 27-60, but 25mm dia. Each 27-61 2958
Same as Item 27-40 to 27-44, 27-60 to 27-61, but fixing only. Each 27-62 78

Same as Item 27-45 to 27-49, 27-50 to 27-54, 27-55 to 27-59, Each 27-63 417
but fixing only.
Add to Item 27-40 to 27-44, 27-60 to 27-61 and 27-62 if Each 27-64 262
removal only.
Add to Item 27-45 to 27-49, 27-50 to 27-54, 27-55 to 27-59 Each 27-65 155
and 27-63, if removal only.
Pipe line digital thermostat, supply and fixing (Digital). Each 27-66 54431
Pipe line pressure gauge, supply and fixing. Each 27-67 18431
Same as item 27-66 and 27-67, but fixing only. Each 27-68 431
Added to item 27-66 and 27-67 or 27-68, if removal only. Each 27-69 324

Installation AC Unit, wall mounted split type upto 1.5 Ton Each 27-70 3578
(except cost of AC unit), kit and electric wiring.
Same as item 27-70, but 2 Ton capacity. Each 27-71 3578
Installation AC unit, floor mounted split type, 3 phase, 5 Ton Each 27-72 6705
capacity, (except cost of AC unit), kit, electric wiring and PCC
foundation.
Same as item 27-72, but upto 10 Ton capacity. Each 27-73 6705
Same as item 27-72, but upto 16 Ton capacity Each 27-74 18765
Same as item 27-72, but upto 20 Ton capacity. Each 27-75 23160
Same as item 27-72, but upto 25 Ton capacity. Each 27-76 27555
Refrigerant Piping
Copper tube ¼ “ dia, supply and fixing. Metre 27-77 357
Same as item 27-77, but ⅜ “ dia. Metre 27-78 538
Same as item 27-77, but ½ “ dia. Metre 27-79 808
Same as item 27-77, but ⅝ “ dia. Metre 27-80 1003
Same as item 27-77, but ¾” dia. Metre 27-81 1297
Same as item 27-77, but ⅞” dia. Metre 27-82 1526
Same as item 27-77, but 1-⅛” dia. Metre 27-83 2267
Same as item 27-77, but 1-⅜” dia. Metre 27-84 3005
Same as item 27-77, but 1-⅝” dia. Metre 27-85 3916
Same as item 27-77 to 27-85, but fixing only. Each 27-86 86
Add to item 27-77 to 27-85 or 27-86, if removal only. Each 27-87 69
Insulation elastomeric nitrite rubber Pipe for Copper tube ¼“ Metre 27-88 105
dia, as per complete specification, supply and fixing.

Same as item No. 27-88, but size 3/8 “ dia. Metre 27-89 111
Same as item 27-88 but ½“ dia. Metre 27-90 117
Same as item No.27-88, but size ⅝ “ dia supply. Metre 27-91 123
Same as item No.27-88, but size 3/4” dia. Metre 27-92 129
Same as item No.27-88, but size 7/8” dia. Metre 27-93 135
Same as item No.27-88, but size 1-1/8” dia. Metre 27-94 165
Same as item No.27-88, but size 1-3/8” dia. Metre 27-95 183
Same as item No.27-88, but size 1-5/8” dia supply and fixing. Metre 27-96 213

Same as item 27-88 to 27-96, but fixing only. Metre 27-97 69


Add to item 27-88 to 27-96 or 27-97, if removing only. Metre 27-98 52
Supply & Fixing, M.S Stand/wall bracket for outdoor unit 0.75 Each 27-99 2141
to 1.5 ton.
Same as item 27-99, but unit 2 to 4 ton. Each 27-100 2591
Same as item 27-99 to 27-100, but fixing only. Each 27-101 173
Add to item 27-99 to 27-101, 27-102, if removal only. Each 27-102 86
VRF (ASIAN ORIGIN)
Supply , fixing, testing and commissioning of heat & cool VRF, Complet 27-103 1021853
DC Inverter type system, with 1 x digital scroll enhance e
vapour injection compressor, including indoor unit,
communications cables, copper tubing from outdoor unit to
indoor unit with proper insulation, condensate drain UPVC
pipe, vacuuming of complete system, pressure/flushing of
complete network with nitrogen gas and charging of
refrigerant R-410-A, complete all as specifications,
manufacturer instructions, rated capacity 8HP suitable on
electric supply 410volts, 3ph, with NL, 50HZ, complete in all
respect with following protection:-
Compressor protection
a. Compressor suction
b. Exhaustion Pressure Protection
c. Compression Ratio Protection
d. Exhausting temperature protection
e. Oil Return protection
Inverter Protection
a. Inverter temperature protection
b. Voltage Protection
System Protection
a. Ventilator pressure protection
b. Four-way valve protection
c. Indoor and outdoor temperature protection
d. Sub cooling protection

Compressor protection
a. Compressor suction
b. Exhaustion Pressure Protection
c. Compression Ratio Protection
d. Exhausting temperature protection
e. Oil Return protection
Inverter Protection
a. Inverter temperature protection
b. Voltage Protection
System Protection
a. Ventilator pressure protection
b. Four-way valve protection
c. Indoor and outdoor temperature protection
d. Sub cooling protection
Electric Protection
a. Voltage phase-failure
b. Current protection
c. Motor protection
d. Protecting from Lightening
(Complete in all respects)
Same as item 27-103, but rated capacity 10HP. Complet 27-104 1241503
e Job
Same as item 27-103, but rated capacity 12HP. Complet 27-105 1453866
e Job
Same as item 27-103, but rated capacity 14HP. Complet 27-106 1657493
e Job
Same as item 27-103, but rated capacity 16HP. Complet 27-107 1803136
e Job
Same as item 27-103, but rated capacity 18HP, with 2 x Complet 27-108 1966319
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 20HP, with 2 x Complet 27-109 2132928
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 22HP, with 2 x Complet 27-110 2679346
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 24HP, with 2 x Complet 27-111 2898996
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 26HP, with 2 x Complet 27-112 3111359
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 28HP, with 2 x Complet 27-113 3314987
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 30HP, with 2 x Complet 27-114 3460628
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 32HP, with 2 x Complet 27-115 3623812
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 34HP, with 3 x Complet 27-116 4149234
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 36HP, with 3 x Complet 27-117 4361597
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 38HP, with 4 x Complet 27-118 4442036
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 40HP, with 4 x Complet 27-119 4710866
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 42HP, with 4 x Complet 27-120 4914494
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 44HP, with 4 x Complet 27-121 5060137
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 46HP, with 4 x Complet 27-122 5281303
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 48HP, with 4 x Complet 27-123 5426947
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 50HP, with 4 x Complet 27-124 5590130
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 52HP, with 4 x Complet 27-125 5735773
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 54HP, with 4 x Complet 27-126 5898956
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 56HP, with 4 x Complet 27-127 6065566
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 58HP, with 6 x Complet 27-128 6232175
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 60HP, with 6 x Complet 27-129 6398784
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 62HP, with 6 x Complet 27-130 7084440
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 64HP, with 6 x Complet 27-131 7247623
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103 to 27-114, but fixing only. Complet 27-132 24000
e Job
Same as item 27-115 to 27-123, but fixing only. Complet 27-133 36000
e Job
Same as item 27-124 to 27-127, but fixing only. Complet 27-134 42000
e Job
Same as item 27-128 to 27-131, but fixing only. Complet 27-135 48000
e Job
Add to item 27-103 to 27-114 or 27-132, if removal only. Complet 27-136 12000
e Job
Add to item 27-115 to 27-123 or 27-133, if removal only. Complet 27-137 18000
e Job
Add to item 27-124 to 27-127 or 27-134, if removal only. Complet 27-138 21000
e Job
Add to item 27-128 to 27-131 or 27-135, if removal only. Complet 27-139 24000
e Job
Indoor Unit
Supply & fixing, testing and commissioning of VRF indoor Complet 27-140 51600
unit, cassette type, 4-way, suitable operation on AC220 volts, e Job
50HZ, electric supply, complete in all respects, rated capacity
0.75 Ton.
Same as item 27-140, but rated capacity, 1 Ton. Complet 27-141 54000
e Job
Same as item 27-140, but rated capacity, 1.25 Ton. Complet 27-142 75600
e Job
Same as item 27-140, but rated capacity, 1.50 Ton. Complet 27-143 81000
e Job
Same as item 27-140, but rated capacity, 2 Ton. Complet 27-144 108000
e Job
Same as item 27-140, but rated capacity, 2.50 Ton. Complet 27-145 135000
e Job
Same as item 27-140, but rated capacity, 3 Ton. Complet 27-146 162000
e Job
Supply, fixing, testing and commissioning of VRF indoor unit Complet 27-147 38400
wall mounted type, suitable operation on AC220 volts, 50 HZ, e Job
electric supply, complete in all respects, rated capacity 0.75
Ton.
Same as item 27-147, but rated capacity, 1 Ton. Complet 27-148 42000
e Job
Same as item 27-147, but rated capacity, 1.25 Ton. Complet 27-149 57000
e Job
Same as item 27-147, but rated capacity, 1.50 Ton. Complet 27-150 63000
e Job
Same as item 27-147, but rated capacity, 2 Ton. Complet 27-151 84000
e Job
Same as item 27-147, but rated capacity, 2.50 Ton. Complet 27-152 105000
e Job
Same as item 27-147, but rated capacity, 3 Ton. Complet 27-153 126000
e Job
Same as item 27-140 to 27-143, 27-147 to 27-150, but fixing Complet 27-154 4000
only. e Job
Same as item 27-144 to 27-146, 27-151 to 27-153, but fixing Complet 27-155 4500
only. e Job
Add to item 27-140 to 27-143, 27-147 to 27-150 or 27-154,if Complet 27-156 2000
removal only. e Job
Add to item 27-144 to 27-146, 27-151 to 27-153 or 27-155, if Complet 27-157 2250
removal only. e Job
Air Cooled Self Contained Package Air – Conditioners

Supply, installation, testing and commissioning of Package Air Each 27-158 1125000
Conditioning Units with compressors, electrical controls,
temperature & pressured controls with special designed heat
exchange coils must be of USA / EU origin to work at high
ambient temperature perfectly. Unit must be completely
wired, piped, charged and run tested in the factory before
shipment to minimize installation time. Complete in all
respect, 5 ton capacity.

Same as item 27-158, but 7.5 ton Capacity. Each 27-159 1687500
Same as item 27-158, but 10 ton Capacity. Each 27-160 2250000
Same as item 27-158, but 12 TR Capacity. Each 27-161 2700000
Same as item 27-158, but 15 ton Capacity. Each 27-162 3375000
Same as item 27-158, but 20 ton Capacity. Each 27-163 4560000
Same as item 27-158, but 25 ton Capacity. Each 27-164 4980000
Same as item 27-158, but 30 ton Capacity. Each 27-165 5400000
Same as item 27-158, but 40 ton Capacity. Each 27-166 7200000
Same as item 27-158, but 50 ton Capacity. Each 27-167 9840000
Same as item 27-158, but 60 ton Capacity. Each 27-168 10560000
Same as item 27-158, but 70 ton Capacity. Each 27-169 11760000
Air Cooled Self Contained Package Air – Conditioners

(Asian Origin)
Supply, installation, testing and commissioning of Package Air Each 27-170 912000
Conditioning Units, with compressors, electrical controls,
temperature & pressured controls, with special designed heat
exchange coils, to work at high ambient temperature
perfectly. Unit must be completely wired, piped, charged and
run tested in the factory before shipment to minimize
installation time. Complete in all respect, 5 ton capacity.

Same as item 27-170, but 7.5 ton Capacity. Each 27-171 1176000
Same as item 27-170, but 10 ton Capacity. Each 27-172 1411200
Same as item 27-170, but 12 ton Capacity. Each 27-173 1881600
Same as item 27-170, but 15 ton Capacity. Each 27-174 2352000
Same as item 27-170, but 20 ton Capacity. Each 27-175 2822400
Same as item 27-170, but 25 ton Capacity. Each 27-176 3528000
Same as item 27-170, but 30 ton Capacity. Each 27-177 4704000
Same as item 27-170, but 40 ton Capacity. Each 27-178 5880000
Same as item 27-170, but 50 ton Capacity. Each 27-179 7056000
Same as item 27-170, but 60 ton Capacity. Each 27-180 8232000
Same as item 27-170, but 70 ton Capacity. Each 27-181 10584000
Same as item 27-158 to 27-161 or 27-170 to 27-173, but Each 27-182 9000
fixing only.
Same as item 27-162 to 27-165 or 27-174 to 27-177, but Each 27-183 22500
fixing only.
Same as item 27-166 to 27-169 or 27-178 to 27-182, but Each 27-184 52500
fixing only.
Add to item 27-158 to 27-161, 27-170 to 27-173 or 27-182, if Each 27-185 4500
removal only.
Add to item 27-162 to 27-165, 27-174 to 27-177 or 27-183, if Each 27-186 11250
removal only.
Add to item 27-166 to 27-169, 27-178 to 27-182 or 27-184, if Each 27-187 26250
removal only.
Air Handling Unit
Supply, installation, testing and commissioning of AHU Each 27-188 1285625
(Normal) with refrigerant, copper piping as specified of
EU/US origin with AHRI/ Euro-vent certified of 10 Ton,
suitable on AC supply 400V, 3 phase, 50 HZ complete all as
specified.
Same as item 27-188, but 15 ton Capacity. Each 27-189 1658914
Same as item 27-188, but 20 ton Capacity. Each 27-190 2081506
Same as item 27-188, but 25 ton Capacity. Each 27-191 2459550
Same as item 27-188, but 30 ton Capacity. Each 27-192 2820272
Same as item 27-188, but 35 ton Capacity. Each 27-193 3174115
Same as item 27-188, but 40 ton Capacity. Each 27-194 3510341
Same as item 27-188, but 45 ton Capacity. Each 27-195 3720267
Same as item 27-188, but 50 ton Capacity. Each 27-196 4074840
Same as item 27-188, but 55 ton Capacity. Each 27-197 4347608
Same as item 27-188, but 60 ton Capacity. Each 27-198 4652337
Supply, installation, testing and commissioning of AHU Each 27-199 1730794
(Hygiene) with refrigerant copper piping all as specified of
EU/US origin with AHRI/Euro-vent certified of 10Ton,
capacity, suitable on AC supply, 400V, 3ph, 50 HZs, complete
all spd.
Same as item 27-199, but 15 ton Capacity. Each 27-200 2381725
Same as item 27-199, but 20 ton Capacity. Each 27-201 2992384
Same as item 27-199, but 25 ton Capacity. Each 27-202 3673901
Same as item 27-199, but 30 ton Capacity. Each 27-203 4329264
Same as item 27-199, but 35 ton Capacity. Each 27-204 4944121
Same as item 27-199, but 40 ton Capacity. Each 27-205 5397824
Same as item 27-199, but 45 ton Capacity. Each 27-206 5930597
Same as item 27-199, but 50 ton Capacity. Each 27-207 6441742
Same as item 27-199, but 55 ton Capacity. Each 27-208 6861373
Same as item 27-199, but 60 ton Capacity. Each 27-209 7309340
Air Handling Unit ( Asian Origin)
Supply, installation, testing and commissioning of AHU Each 27-210 876000
(Normal) with refrigerant, copper piping as specified for Asian
Origin 10 Ton, suitable on AC supply 400V, 3phase, 50HZs,
complete all as specified.
Same as item 27-210, but 15 ton Capacity. Each 27-211 1404000
Same as item 27-210, but 20 ton Capacity. Each 27-212 1800000
Same as item 27-210, but 25 ton Capacity. Each 27-213 2196000
Same as item 27-210, but 30 ton Capacity. Each 27-214 2720640
Same as item 27-210, but 35 ton Capacity. Each 27-215 3054000
Same as item 27-210, but 40 ton Capacity. Each 27-216 3384000
Same as item 27-210, but 45 ton Capacity. Each 27-217 4044000
Same as item 27-210, but 50 ton Capacity. Each 27-218 4704000
Same as item 27-210, but 55 ton Capacity. Each 27-219 4764000
Same as item 27-210, but 60 ton Capacity. Each 27-220 5364000
Supply, installation, testing and commissioning of AHU Each 27-221 983400
(Hygiene) with refrigerant copper piping all as specified for
Asian Origin, 10 Ton Capacity, Suitable on AC supply, 400V,
3ph, 50 HZs complete all spd.
Same as item 27-221, but 15 ton Capacity. Each 27-222 1331701
Same as item 27-221, but 20 ton Capacity. Each 27-223 1748734
Same as item 27-221, but 25 ton Capacity. Each 27-224 2170770
Same as item 27-221, but 30 ton Capacity. Each 27-225 2406468
Same as item 27-221, but 35 ton Capacity. Each 27-226 2593656
Same as item 27-221, but 40 ton Capacity. Each 27-227 3169243
Same as item 27-221, but 45 ton Capacity. Each 27-228 3495662
Same as item 27-221, but 50 ton Capacity. Each 27-229 3780731
Same as item 27-221, but 55 ton Capacity. Each 27-230 4215758
Same as item 27-221, but 60 ton Capacity. Each 27-231 4627610
Supply, installation, testing and commissioning of AHU Each 27-232 2581974
(Medical grade) with pre & bag filters refrigerant copper
piping all as specified of Asian Origin,10 Ton Capacity,
Suitable on AC supply, 400V, 3ph, 50HZs complete in all
respect as per drawing & specification.
Same as item 27-232, but 15 ton Capacity. Each 27-233 3820374
Same as item 27-232, but 20 ton Capacity. Each 27-234 5058774
Same as item 27-232, but 25 ton Capacity. Each 27-235 6336774
Same as item 27-232, but 30 ton Capacity. Each 27-236 7492374
Same as item 27-188 to 27-191, 27-199 to 27-202, 27-210 to Each 27-237 18774
27-213, 27-221 to 27-224 or 27-232 to 27-236, but fixing
only.
Same as item 27-192 to 27-194, 27-203 to 27-205, 27-214 to Each 27-238 33750
27-216 or 27-225 to 27-227, but fixing only.

Same as item 27-195 to 27-198, 27-206 to 27-209, 27-217 to Each 27-239 45000
27-220 or 27-228 to 27-231, but fixing only.

Add to item 27-188 to 27-191, 27-199 to 27-202, 27-210 to Each 27-240 9387
27-213, 27-221 to 27-224, 27-232 to 27-236 or 27-237, if
removal only.
Add to item 27-192 to 27-194, 27-203 to 27-205, 27-214 to Each 27-241 16875
27-216, 27-225 to 27-227 or 27-238, if removal only.

Add to item 27-195 to 27-198, 27-206 to 27-209, 27-217 to Each 27-242 22500
27-220, 27-228 to 27-231 or 27-239, if removal only.

Supply, installation, testing and commissioning of air cooled Each 27-243 838000
condensing unit (CU), direct expansion (Dx) type, of EU/US
origin, AHRI/Euro vent certified, with power supply of 400 V,
3ph, 50 HZs with all necessary controls and compressor scroll
type, semi hermetic, of 5 ton capacity, complete in all
respect.
Same as item 27-243, but 10 ton Capacity. Each 27-244 1526005
Same as item 27-243, but 15 ton Capacity. Each 27-245 2173139
Same as item 27-243, but 20 ton Capacity. Each 27-246 2832496
Same as item 27-243, but 25 ton Capacity. Each 27-247 3419220
Same as item 27-243, but 30 ton Capacity. Each 27-248 4057807
Same as item 27-243, but 35 ton Capacity. Each 27-249 4695420
Same as item 27-243, but 40 ton Capacity. Each 27-250 5224891
Same as item 27-243, but 45 ton Capacity. Each 27-251 5746652
Same as item 27-243, but 50 ton Capacity. Each 27-252 6331136
Same as item 27-243, but 55 ton Capacity. Each 27-253 6773497
Same as item 27-243, but 60 ton Capacity. Each 27-254 7204633
Supply, installation, testing and commissioning of air cooled Each 27-255 624000
condensing unit (CU), direct expansion (Dx) type, of Asian
origin with power supply of 400V, 3ph, 50HZs with all
necessary controls and compressor scroll type, semi
hermetic, of 5 ton capacity, complete in all respect.

Same as item 27-255, but 10 ton Capacity. Each 27-256 936000


Same as item 27-255, but 15 ton Capacity. Each 27-257 1560000
Same as item 27-255, but 20 ton Capacity. Each 27-258 2028000
Same as item 27-255, but 25 ton Capacity. Each 27-259 2340000
Same as item 27-255, but 30 ton Capacity. Each 27-260 3120000
Same as item 27-255, but 35 ton Capacity. Each 27-261 3510000
Same as item 27-255, but 40 ton Capacity. Each 27-262 3900000
Same as item 27-255, but 45 ton Capacity. Each 27-263 4680000
Same as item 27-255, but 50 ton Capacity. Each 27-264 5460000
Same as item 27-255, but 55 ton Capacity. Each 27-265 5570000
Same as item 27-255, but 60 ton Capacity. Each 27-266 6240000
Same as item 27-243 to 27-246 or 27-255 to 27-258, but Each 27-267 15000
fixing only.
Same as item 27-247 to 27-250 or 27-259 to 27-262, but Each 27-268 30000
fixing only.
Same as item 27-251 to 27-254 or 27-263 to 27-266, but Each 27-269 45000
fixing only.
Add to item 27-243 to 27-246, 27-255 to 27-258 or 27-267, if Each 27-270 7500
removal only.
Add to item 27-247 to 27-250, 27-259 to 27-262 or 27-268, if Each 27-271 15000
removal only.
Add to item 27-251 to 27-254, 27-263 to 27-266 or 27-269, if Each 27-272 22566
removal only.
Supply, installation, testing and commissioning of DCs Each 27-273 144000
Inverter type ACs split unit, heat and cool consisting of indoor
units, (wall mounted type), outdoor unit including, copper
tubing with proper insulation and condensate drain pipe,
electric connection from indoor unit to outdoor unit,
complete in all respect with wireless remote control, 1 ton
capacity.
Same as item 27-273, but 1.5 ton Capacity. Each 27-274 228000
Same as item 27-273, but 2.5 ton Capacity. Each 27-275 450000
Same as item 27-273, but Cassette type 4 way indoor unit 1.5 Each 27-276 265500
ton Capacity.
Same as item 27-276, but 2 ton Capacity. Each 27-277 354000
Same as item 27-276, butt 3 ton Capacity. Each 27-278 564000
Same as item 27-276, butt 4 ton Capacity. Each 27-279 642000
Same as item 27-273 to 27-275, but fixing only. Each 27-280 3000
Same as item 27-276 to 27-279, but fixing only. Each 27-281 4500
Add to item 27-273 to 27-275 or 27-280, if removal only. Each 27-282 1500
Add to item 27-276 to 27-279 or 27-281, if removal only. Each 27-283 2250

Air Cooled Chillers System


Supply, installation testing and commissioning of complete air Ton 27-284 240000
cooled chiller system with outdoor air cooled Chillers, chilled
water piping network with proper insulation and controls,
water pumping sets, Air handing units, G.I insulated ducts
with air flow control devices, humidifier, air and water filters,
controls with safeties, air exhaust system, fan coil units etc
complete in all respect as per drawing and specification.

Water Cooled Chillers System


Supply, installation, testing and commissioning of water Ton 27-285 280000
cooled system, with water cooled Chiller, air handling units,
chilled water piping with proper insulation and control
network, air control devices, fan coil units, air exhaust
system, water pumping sets, cooling tower with piping and
electric connection network, humidifier, air & water filters
and controls with safeties etc complete in all respect as per
drawings and specification.

Hot Water System for Heating


Supply, installation, testing and commissioning of hot water Ton 27-286 290000
system, including hot water generator, operated at natural
gas or oil, hot water piping network with insulation, with all
control and safeties, electrical connection etc. complete in all
respect as per drawings and specification.

Passengers / Cargo Lifts / Elevators


Supply, installation, testing & commissioning of passengers / Each 27-287 7500000
cargo lift with motor 415V, 3ph, AC, 50Hzs supply, suitable to
serve 07 floors, with AC Variable Voltage & Variable
Frequency drive (VVVF) complete with all standard
accessories, for upto 630 Kg, including all applicable safeties
complete in all respect as per drawing and specification, as
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. EU origin.

Supply, installation, testing & commissioning of passengers / Each 27-288 9700000


cargo lift with motor 415V, 3 phase, AC, 50 Hzs, supply,
suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, upto 800 Kg, including all applicable safeties
complete in all respect as per drawing and specification, as
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. EU origin.
Supply, installation, testing & commissioning of passengers / Each 27-289 10200000
cargo lift with motor 415 volts, 3ph, AC, 50Hzs supply,
suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, upto 1000 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. EU origin.

Supply, installation, testing & commissioning of passengers / Each 27-290 16300000


cargo lift with motor 415 V, 3 phase, AC, 50Hzs supply,
suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, for upto 1600 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. EU origin.

Passengers / Cargo Lifts / Elevators (Asian Origin)

Supply, installation, testing & commissioning of passengers / Each 27-291 5100000


cargo lift with motor 415 V, 3ph, AC, 50Hzs supply, suitable
to serve 07 floors with AC Variable Voltage & Variable
Frequency drive (VVVF drive) complete with all standard
accessories, for upto 630 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. Asian origin.

Passengers / cargo lift with motor 415 V, 3ph, AC 50Hzs Each 27-292 5200000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF drive) complete with all
standard accessories, for upto 800 Kg, including all applicable
safeties complete in all respect as per drawing and
specification. As latest edition of applicable standards of
ANSI, ASME, BS/EN, AWS, NFPA, ASTM, NEMA and IEE etc.
Asian origin.
Passengers / cargo lift with motor 415 V, 3ph, AC, 50Hzs Each 27-293 5300000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, for upto 1000 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. Asian origin.
Passengers / cargo lift with motor 415 V, 3ph, AC, 50Hzs Each 27-294 6000000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, for upto 1600 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM,NEMA and IEE etc. Asian origin.

Servicing / Maintenance / Monthly inspection as per OEM One Job 27-295 15000
standard of Elevators, all as specified.
GANTRY EOT CRANES
Supply, fixing, Testing and Commissioning of EOT Crane, span Each 27-296 11225000
12 metre, Bay length 15.2 metre, Height of lift 7.76 metre
capacity 5 Tonne single girder, including cabals, Control
Panels and EOT kit suitable operation on 410/220 Volts, 3
Phase with NL, complete in all respect as per drawings and
specification.

Same as Item 27-296, but Capacity 7.50 Tonne Single girder. Each 27-297 12000000

Same as Item 27-296, but Capacity 10.00 Tonne Double Each 27-298 13554910
girder.
Same as Item 27-296, but Capacity 15.00 Tonne Double Each 27-299 16400000
girder.
Same as Item 27-296, but Capacity 20.00 Tonne Double Each 27-300 18600000
girder.
Same as Item 27-296, but Capacity 25.00 Tonne Double Each 27-301 20060000
girder.
Same as Item 27-296, but Capacity 30.00 Tonne Double Each 27-302 27900000
girder.
Same as Item 27-296, but Capacity 35.00 Tonne Double Each 27-303 28800000
girder.
Same as Item 27-296, but Capacity 5.00 Tonne single girder, Each 27-304 11725000
span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 7.50 Tonne single girder, Each 27-305 12500000
span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 10.00 Tonne double Each 27-306 14154910
girder, span 20.00 metre, bay length 15.20 metre.

Same as Item 27-304, but Capacity 15.00 Tonne double Each 27-307 17400000
girder, span 20.00 metre, bay length 15.20 metre.

Same as Item 27-304, but Capacity 20.00 Tonne double Each 27-308 19800000
girder, span 20.00 metre, bay length 15.20 metre.

Same as Item 27-304, but Capacity 25.00 Tonne double, span Each 27-309 21600000
20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 30.00 Tonne double Each 27-310 29800000
girder, span 20.00 metre, bay length 15.20 metre.

Same as Item 27-304, but Capacity 35.00 Tonne double Each 27-311 30800000
girder, span 20.00 metre, bay length 15.20 metre.

Explosion Proof EOT Cranes


Supply, fixing, Testing and Commissioning of Explosion proof Each 27-312 33500000
EOT Crane, span 5 metre, bay length 5 metre, height of lift 5
metre, capacity 2 Tonne, double girder, including Cables,
Control Panels and EOT kit suitable operation on 410/220V,
3Ph with NL. Complete in all respect as per drawings and
specification.
Same as Item 27-312, but 5 Tonne capacity, span 12 Metre, Each 27-313 14905000
bay length 30 metre, lift of height 8 metre, single girder.

Same as Item 27-312, but 15 Tonne Capacity, Span14 Metre, Each 27-314 54093531
bay length 20.42 metre, lift of height 9.1 metre, double
girder.
Standard Manual Cranes
Supply, fixing, Testing and Commissioning of all motion Each 27-315 3600000
manual control crane, span 16 metre, bay length 30 metre,
Height of lift 4.3 metre, capacity 3 Tonne single girder,
complete in all respect as per drawings and specification.

Same as Item 27-315, but 3 Tonne capacity, span 12 Metre, Each 27-316 3227566
bay length 20 metre, lift of height 4.3 metre.
Same as Item 27-315, but 3 Tonne capacity, span 9 Metre, Each 27-317 2945318
bay length 12 metre, lift of height 4.3 metre.
Same as Item 27-315, but 3 Tonne capacity, span 14 Metre, Each 27-318 2900000
bay length 16 metre, lift of height 4.5 metre.
Manual Cranes Ex Class
Supply, fixing, Testing and Commissioning of All motion Each 27-319 6200000
manual control Ex class crane, span 4 metre, bay length 24
metre, height of lift 3.0 metre, capacity 3 Tonne single girder,
complete in all respect as per drawings and specification.

Generator Set
Supply, installation, testing and commissioning of Diesel Each 27-320 1467270
Engine Prime rating Generator in accordance with ISO-3046,
ISO-9001:2015, BS-5514, DIN-6271, AS-2789, 2014/3/EU
electromagnetic compatibility and 2000/14/EC, noise
emission for outdoor use. Engine and alternator mounted on
robust skid frame including fuel tank, control panel, diesel
engine four stroke, water cooled 1500 RPM, built in battery
charger, batteries and brushless self-excited alternator,
400/230V, 3 phase and NL, 50 Hz, power factor 0.8, with ATS
panels but without canopy, (CBU) complete assembled,
integrated/manufactured in EU, UK & USA 09 KVA.

Same as item 27-320, but 14 KVA. Each 27-321 1619370


Same as item 27-320, but 20 KVA. Each 27-322 2047220
Same as item 27-320, but 30 KVA. Each 27-323 2122900
Same as item 27-320, but 40 KVA. Each 27-324 2284390
Same as item 27-320, but 60 KVA. Each 27-325 2857690
Same as item 27-320, but 80 KVA. Each 27-326 2916250
Same as item 27-320, but 100 KVA. Each 27-327 3167800
Same as item 27-320, but 120 KVA. Each 27-328 3635800
Same as item 27-320, but 150 KVA. Each 27-329 4349000
Same as item 27-320, but 180 KVA. Each 27-330 5109500
Same as item 27-320, but 200 KVA. Each 27-331 5628300
Same as item 27-320, but 250 KVA. Each 27-332 7294000
Same as item 27-320, but 300 KVA. Each 27-333 8906100
Same as item 27-320, but 350 KVA. Each 27-334 9573000
Same as item 27-320, but 380 KVA. Each 27-335 10755267
Same as item 27-320, but 400 KVA. Each 27-336 11037000
Same as item 27-320, but 450 KVA. Each 27-337 11534250
Same as item 27-320, but 500 KVA. Each 27-338 14168000
Same as item 27-320, but 590 KVA. Each 27-339 16040000
Same as item 27-319, but 650 KVA. Each 27-340 18380000
Same as item 27-320, but 700 KVA. Each 27-341 27155000
Same as item 27-320, but 800 KVA. Each 27-342 28442000
Same as item 27-320, but 1000 KVA. Each 27-343 32069000
Same as item 27-320, but 1250 KVA. Each 27-344 41110000
Supply, installation, testing and commissioning of Diesel Each 27-345 1181250
Engine Prime rating Generator in accordance with ISO-3046,
ISO-9001:2015, BS-5514, DIN-6271, AS-2789, 2014/3/EU
electromagnetic compatibility and 2000/14/EC, noise
emission for outdoor use. Engine and alternator mounted on
robust skid frame including fuel tank, control panel, diesel
engine four stroke, water cooled 1500 RPM, built in battery
charger, batteries and brushless self-excited alternator,
400/230 volt 3 phase and NL, 50Hzs power factor 0.8, and
ATS panel, without canopy, locally assembled, manufactured
in EU, UK & USA 15 KVA.

Same as item 27-345, but 20 KVA. Each 27-346 1393750


Same as item 27-345, but 30 KVA. Each 27-347 1668750
Same as item 27-345, but 45 KVA. Each 27-348 1912500
Same as item 27-345, but 60 KVA. Each 27-349 2156250
Same as item 27-345, but 80 KVA. Each 27-350 2656250
Same as item 27-345, but 100 KVA. Each 27-351 2878750
Same as item 27-345, but 150 KVA. Each 27-352 4335000
Same as item 27-345, but 200 KVA. Each 27-353 5122500
Same as item 27-345, but 250 KVA. Each 27-354 6560000
Same as item 27-345, but 300 KVA. Each 27-355 8360000
Same as item 27-345, but 350 KVA. Each 27-356 8735000
Same as item 27-345, but 400 KVA. Each 27-357 10121250
Same as item 27-345, but 500 KVA. Each 27-358 12070000
Same as item 27-345, but 650 KVA. Each 27-359 15315500
Same as item 27-345, but 800 KVA. Each 27-360 22535000
Same as item 27-345, but 1250 KVA. Each 27-361 40390000
Same as item 27-320 to 27-324 or 27-345 to 27-348, but Each 27-362 15000
fixing only.
Same as item 27-325 to 27-329 or 27-349 to 27-352, but Each 27-363 30000
fixing only.
Same as item 27-330 to 27-334 or 27-353 to 27-356, but Each 27-364 50000
fixing only.
Same as item 27-335 to 27-339 or 27-357 to 27-358, but Each 27-365 55000
fixing only.
Same as item 27-340 to 27-344 or 27-359 to 27-361, but Each 27-366 65000
fixing only.
Add to item 27-320 to 27-324, 27-345 to 27-348 or 27-362, if Each 27-367 7500
removal only.
Add to item 27-325 to 27-329, 27-349 to 27-352 or 27-363, if Each 27-368 15000
removal only.
Add to item 27-330 to 27-334, 27-353 to 27-356 or 27-364, if Each 27-369 25146
removal only.
Add to item 27-335 to 27-339, 27-357 to 27-358 or 27-365, if Each 27-370 27486
removal only.
Add to item 27-340 to 27-344, 27-359 to 27-361 or 27-366, if Each 27-371 32500
removal only.
Supply, installation of Locally Fabricated weather and sound Each 27-372 69000
proof canopy, including main frame structure made of 14
SWG, epoxy painted insulation material (Glass wool),
complete in all respect with noise level 84 dBA at 1 meter
distance, for 15 KVA generator set.
Same as item 27-372, but 20 KVA. Each 27-373 80500
Same as item 27-372, but 30 to 60 KVA. Each 27-374 115000
Same as item 27-372, but 80 to 100 KVA. Each 27-375 149500
Same as item 27-372, but 150 KVA. Each 27-376 230000
Same as item 27-372, but 200 KVA. Each 27-377 253000
Same as item 27-372, but 250 KVA. Each 27-378 345000
Same as item 27-372, but 300 KVA. Each 27-379 402500
Same as item 27-372, but 350 to 400 KVA. Each 27-380 488750
Same as item 27-372, but 500 KVA. Each 27-381 575000
Same as item 27-372, but 650 KVA. Each 27-382 747500
Same as item 27-372, but 800 KVA. Each 27-383 920000
Same as item 27-372, but 1000 KVA. Each 27-384 1150000
Same as item 27-372 to 27-376, but fixing only. Each 27-385 6000
Same as item 27-377 to 27-380, but fixing only. Each 27-386 9000
Same as item 27-381 to 27-384, but fixing only. Each 27-387 15000
Add to item 27-372 to 27-376 or 27-385, if removal only. Each 27-388 3000

Add to item 27-377 to 27-380 or 27-386, if removal only. Each 27-389 4500

Add to item 27-381 to 27-384 or 27-387, if removal only. Each 27-390 7500

Solar Energy System


Supply installation testing and commissioning of electric solar Watt 27-391 95
energy system, including PV modules, PV module mounting
system, sun tracking system where required, inverters, AC/DC
cable network, smart energy meter, all protection and safties,
earthing, lightning protection system, Electrical panels board
and maintenance free batteries as per drawing and
specifications.

Medical Gases – Each BED for OT


Supply installation, testing commissioning, BED Head unit Bed 27-392 Please refer
horizontal type, comprising of bed/reading light with on/off to
switch, multi pin socket, nurse call/alert button, complete supplement
electric wiring, master alarm panel, monitor shelf, air vacuum ary
complete set along with seamless medical grade copper pipe, Instructions
multiple zone valve box and cylinder type duplex air dryer &
filtration system, automatic oxygen, nitrogen Manifold,
Medical compressed Air Station, Flow meter with humidifier,
gas outlets terminal unit, multi movement double arm,
complete in all respect as per drawing specification.

Each BED for Ward


Supply, installation, testing, commissioning, BED Head unit Bed 27-393 Please refer
Horizontal type comprising of bed/reading light with on/off to
switch multi pin socket, nurse call/alert button, complete supplement
electric wiring, master alarm panel, monitor shelf, air vacuum ary
complete set, along with seamless medical grade copper Instructions
pipe, multiple zone valve box and cylinder type duplex air
dryer & filtration system, automatic Oxygen, medical
compressed air station, flow meter with humidifier, gas
outlets terminal unit, multi movement, double arm, complete
as per drawings/ specification.

Public Address System


Supply & fixing of ceiling speaker, circular horn speaker Sqm 27-394 Please refer
power, PVC conduit polyethylene insulation tinned copper to
Conductor, twin core cable 1.5mm2/450/0.2mm, power supplement
amplifier cabinet, handheld microphone set corded Wireless ary
hand held microphone blue tooth complete in all respect of Instructions
approved quality. (Covered Area Rate (i.e. Rates / Sft),
complete as per drawings / specification.

Fire Extinguishing and Suppression System


Supply, fixing, testing, commissioning of IP addressable fire Sqm 27-395 Please refer
detection and alarm system comprising of smoke detector, to
heat detector, multi detector, manual call point (break glass supplement
type) electronic sounder with LED flushing light, IP ary
addressable fire alarm control panel alongwith input and Instructions
output module low smoke electric wiring with FR cable in PVC
conduct all as specified (covered Area Rate i.e Rate/Sqft),
complete as per drawings / specification.

Description Unit SI No. Rate (Rs)


Acrylic based rubberized liquid membrane. Sqm 28-1 453
Admixture for Concrete. Ltr 28-2 365
Alpha / Rim Lock, Standard Quality. Each 28-3 886
Alpha / Rim Lock, Deluxe Quality. Each 28-4 1288
Alpha / Rim Lock, Premium Quality. Each 28-5 2184
Aluminium Door Handle, Deluxe Quality. Each 28-6 221
Aluminium Fly/ Insect Screening, Deluxe and Premium Sqm 28-7 4304
Quality.
Aluminium Steel Sheet, 18 B.G. Kg 28-8 856
Aluminium Steel Sheet, 20 B.G. Kg 28-9 453
Aluminium strip, 100 mm wide. Mtr 28-10 197
Aluminium stud, flush type 10 cm x 20 cm x 2 cm. Each 28-11 640
Anti-static tiles, 3 mm thick, 300 x 300 mm. Sqm 28-12 1949
Ash Wood. Cum 28-13 206068
Basin Mixer, Standard Quality. Each 28-14 4500
Basin Mixer, Deluxe Quality. Each 28-15 6420
Basin Mixer, Premium Quality. Each 28-16 9500
Bath Cabinet. Each 28-17 2767
Bath curtain, (1.78 x 1.78m). Each 28-18 755
Bib cock, CP. Each 28-19 842
Bitumen felt, Two Ply. Sqm 28-20 211
Asphalt cement, grade 10-20. Tonne 28-21 117000
Asphalt cement, grade 60-70 / 80-100. Tonne 28-22 91000
Bitumen washer. Each 28-23 8
Binding wire 14 – 18 SWG. Ton 28-24 129000
Bolt Kit. Each 28-25 151
Bolts 10 mm dia length not exceeding 75 mm. Each 28-26 20
Bolts 10 mm dia length exceeding 75 mm but not exceeding Each 28-27 25
150 mm.
Bolts 10 mm dia length exceeding 150 mm but not exceeding Each 28-28 60
300 mm.
Bolts 10 mm to 18 mm dia length not exceeding 75 mm. Each 28-29 59

Bolts 10 mm to 18 mm dia length exceeding 75 mm but not Each 28-30 64


exceeding 150 mm.
Bolts 10 mm to 18 mm dia length exceeding 150 mm but not Each 28-31 89
exceeding 300 mm.
Bolts 18 mm to 25 mm dia, length not exceeding 75 mm. Each 28-32 101

Bolts 18 mm to 25 mm dia, length exceeding 75 mm but not Each 28-33 171


exceeding 150 mm.
Bolts 18 mm to 25 mm dia, length exceeding 150 mm but not Each 28-34 221
exceeding 300 mm.
Bottle trap. Each 28-35 1308
Boulders, for retaining wall. Cum 28-36 1295
Bracket for sink. Pair 28-37 302
Brick tiles, 300 x 150 x 38 mm. M.Nos 28-38 16000
Brick tiles, 300 x 150 x 50 mm. M.Nos 28-39 20000
Bricks, burnt 1st class. M.Nos 28-40 12000
Brick Bat. Each 28-41 6
Brush / Tumbler holder (Plastic). Each 28-42 433
Building paper. Sqm 28-43 39
Carpet Tiles Fixed with Glue. Sqm 28-44 2544
Casted grating 100 mm x 100 mm. Each 28-45 392
Casted grating 150 mm x 150 mm. Each 28-46 554
Cement - Sulphate Resisting (50 Kg packing). Bag 28-47 540
Cement, Ordinary (50 Kg packing). Bag 28-48 515
Cement, white / coloured (40 Kg packing). Bag 28-49 1340
Chipboard, 13 mm thick. Sqm 28-50 395
Chipboard, 19 mm thick. Sqm 28-51 454
Chipboard, 25 mm thick. Sqm 28-52 622
Chip Board Veneered, 19 mm thick Sqm 28-53 824
Chopped straw (Bhoosa). Kg 28-54 17
CI Floor Trap including Reducer. Each 28-55 1711
Cistern flushing with fittings. Each 28-56 1811
Cistern Low Down Glazed. Each 28-57 2515
Screw Brass 150 mm. Each 28-58 18
Closet Pan in any Colour. Each 28-59 2516
Commercial Ply 3 mm. Sqm 28-60 366
Concertina / Razor wire 12 SWG, loop dia 0.450 to 0.991 M. Metre 28-61 396

Connection Brass 15 mm dia. Each 28-62 181


Copper float valve 20 mm dia. Each 28-63 383
Copper sheet 24 gauge. Sqm 28-64 5380
Copper sheet 26 gauge. Sqm 28-65 4304
Corner Shelf in any size and Shape. Each 28-66 1610
Cover Strip Aluminium, 60 mm wide and 2 mm thick. Meter 28-67 230
Cover Strip Aluminium, 60 mm wide and 2 mm thick in Meter 28-68 459
sections.
Crushed Aggregates with maximum nominal size of 100 mm Cum 28-69 1410
graded.
Crushed Aggregates with maximum nominal size of 13 mm to Cum 28-70 1589
19 mm graded.
Crushed Aggregates with maximum nominal size of 25 mm to Cum 28-71 1518
38 mm graded
Crushed Aggregates with maximum nominal size of 3 mm Cum 28-72 1510
graded.
Crushed Aggregate with maximum nominal size of 3 mm to 6 Cum 28-73 1530
mm graded.
Crushed Aggregate with maximum nominal size of 50 mm Cum 28-74 1490
graded
Crushed Aggregate with maximum nominal size of 63 mm Cum 28-75 1440
graded.
Crushed Aggregate with maximum nominal size of 75 mm Cum 28-76 1236
graded.
Deformed Bar, Grade 40. Tonne 28-77 111000
Deformed Bar, Grade 60. Tonne 28-78 113000
Crystalline water proofing Admixture. Kg 28-79 800
Crystalline water proofing coating. Sqm 28-80 160
Door Closer Aluminium, single action, Deluxe Quality. Each 28-81 1610
Door Closer Aluminium, single action, Premium Quality. Each 28-82 1912

Door Closer Aluminium, Double action. Each 28-83 9559


Double Bib Cock, Standard Quality. Each 28-84 2211
Double Bib Cock, Deluxe Quality. Each 28-85 3702
Double Bib Cock, Premium Quality. Each 28-86 4400
Dry bond Kg 28-87 12
Expansion cap, 25 mm to 40 mm dia (Plastic). Each 28-88 200
Expanded Metal (XPM), 25 mm x 25 mm x 2 mm, 16 gauge. Sqm 28-89 411

Expanded Metal (XPM), 38m mx 44 mm x 2 mm, 18 gauge. Sqm 28-90 217

Expanded Metal (XPM), 38 mm x 44 mm x 2 mm, 16 gauge. Sqm 28-91 281

Expanded Metal (XPM), 25 mm x 25 mm x 2 mm, 18 gauge. Sqm 28-92 325

Facing Stone, 300 x 150 x 10 mm. Sqm 28-93 596


Fiber Glass Sheets, 1 mm thick. Sqm 28-94 703
Fiber Glass Sheets, 2 mm thick. Sqm 28-95 1624
Fiber Glass Sheets, 3 mm thick. Sqm 28-96 2260
Fiber Washer. Each 28-97 5
Fire wood. Kg 28-98 19
Fillet Soft wood. Meter 28-99 89
Flush Connection PVC. Each 28-100 151
Flush Pipe Plastic long type. Each 28-101 201
Flush tank Concealed type. Each 28-102 17237
Frosted Paper. Sqm 28-103 1083
GI Barbed wire, 12 SWG. Metre 28-104 33
GI Barbed wire, 14 SWG. Meter 28-105 19
Glass Sheet, 3 mm thick. Sqm 28-106 693
Glass Sheet, 10 mm thick. Sqm 28-107 2328
Glass Sheet, 12 mm thick. Sqm 28-108 2652
Glass Sheet, 5 mm thick. Sqm 28-109 996
Glass Sheet, 8 mm thick. Sqm 28-110 1678
Glass Sheet frosted, 3 mm thick. Sqm 28-111 823
Glass Sheet frosted, 5 mm thick. Sqm 28-112 1115
Glass Sheet milky, 5 mm thick. Sqm 28-113 1429
Glass Sheet tinted, (Double Glazing) 5 mm thick. Sqm 28-114 1305
Glass Sheet tinted, 5 mm thick. Sqm 28-115 1115
Glass Sheet tinted, 8 mm thick. Sqm 28-116 2761
Glass Tempered of any thickness. Sqm 28-117 1624
Glue. Kg 28-118 200
Granular sub base. Cum 28-119 1412
Gutka tiles of different Sizes. Sqm 28-120 909
Gypsum Sheet decorative 1200 mm x 2400 mm x 12.50 mm Sqm 28-121 900
thick with Aluminium Tee / Angle 25 mm x 25 mm x 1 mm.

1st Class Hard Wood Sheesham. Cum 28-122 123585


Hand Shower, Standard Quality. Each 28-123 1500
Hand Shower, Deluxe Quality. Each 28-124 2500
Hand Shower, Premium Quality. Each 28-125 3100
Head, Standard Quality. Each 28-126 400
Head, Deluxe Quality. Each 28-127 660
Head, Premium Quality. Each 28-128 900
High Tensile carbon steel wire. Kg 28-129 231
Hydraulic Door Closer. Each 28-130 1862
Hydraulic seat Cover. Each 28-131 2700
Kerb stone 300 mm x 300 mm x 150 mm. Each 28-132 100
Kerb stone 350 mm x 300 mm x 150 mm. Each 28-133 120
Kerb stone 450 mm x 300 mm x 150 mm. Each 28-134 150
L hook 10 mm dia for roof. Each 28-135 25
Lacquer Polish. Ltr 28-136 604
Latch CP 150 mm. Each 28-137 503
Lime un-slaked. Kg 28-138 14
Limpet washers. Each 28-139 6
Malaysian Ply Wood 3 mm. Sqm 28-140 366
1st Class hard wood Mahogany. Cum 28-141 202515
MDF Laminated Sheet, 10 mm thick. Sqm 28-142 588
MDF Laminated Sheet, 16 mm thick. Sqm 28-143 891
MDF Laminated Sheet, 24 mm thick. Sqm 28-144 1496
Mineral Acoustic Sheet ceiling 600 x 600 x 12 mm. Sqm 28-145 1570
Mirror 5 mm thick any shape. Sqm 28-146 1056
Mirror 5 mm thick. Each 28-147 604
Marble Patty 8 to 10 mm thick and 40 mm wide Meter 28-148 27
MS Hollow Pipe 1 ½” x 1 ½”, Square 16 gauge. Meter 28-149 246
MS Hollow Pipe 1 ½” x 1 ½”, Square 18 gauge. Meter 28-150 191
MS Hollow Pipe 1 ½” x 1”, Rectangular 16 gauge. Meter 28-151 213
MS Hollow Pipe 1 ½” x 1”, Rectangular 18 gauge. Meter 28-152 164
MS Hollow Pipe 1 ¼” x 1 ¼”, Square 16 gauge. Meter 28-153 197
MS Hollow Pipe 1 ¼” x 1 ¼”, Square 18 gauge. Meter 28-154 149
MS Hollow Pipe 1” x 1”, Square 16 gauge. Meter 28-155 126
MS Hollow Pipe 1” x 1”, Square 18 gauge. Meter 28-156 123
MS Hollow Pipe 2” x 1 ½”, Rectangular 18 gauge. Meter 28-157 228
MS Hollow Pipe 2” x ½”, Square 16 gauge. Meter 28-158 305
MS Hollow Pipe 2” x 2”, Square 16 gauge. Meter 28-159 300
MS Hollow Pipe 2” x 2”, Square 18 gauge. Meter 28-160 228
MS Hollow Pipe 3” x 3”, Square 16 gauge. Meter 28-161 585
MS Hollow Pipe 3” x 3”, Square 18 gauge. Meter 28-162 446
Nail Galvanised. kg 28-163 352
Nail wire. kg 28-164 252
P or S Trap. Each 28-165 191
P.V.C Waste Pipe. Each 28-166 71
Paint Camouflaging. Ltr 28-167 387
Paint Road Marking. Ltr 28-168 406
Paint Synthetic Enamel. Ltr 28-169 320
Paint Weather resistant. Ltr 28-170 516
Paint Aluminium. Lit 28-171 387
Paving Stone Natural colour, 50 mm thick. Sqm 28-172 426
Paving Stone any Colour, 50 mm thick. Sqm 28-173 455
Paving Stone Natural Colour, 60 mm thick. Sqm 28-174 465
Paving Stone any Colour, 60 mm thick. Sqm 28-175 488
Paving Stone Natural Colour, 80 mm Thick. Sqm 28-176 630
Paving Stone, any Colour, 80 mm thick. Sqm 28-177 667
PCC hollow block (0.400 x 0.200 x 0.150 Mtr) Load Bearing. Each 28-178 67

PCC solid block (0.300 x 0.200 x 0.150 Mtr) Load Bearing. Each 28-179 50

PCC solid block (0.300 x 0.200 x 0.150 Mtr) Non Load Each 28-180 44
Bearing.
PCC hollow block (0.400 x 0.200 x 0.150 Mtr) Non Load Each 28-181 59
Bearing.
Pedestal any Colour. Each 28-182 1660
Pillar cock, CP. Each 28-183 1351
Plastic Bath Cabinet, 450 mm x 450 mm x 100 mm. Each 28-184 2767
Plastic Connection, 15 mm-Plastic union both end. Each 28-185 141
Plastic connection, 20 mm dia Brass. Each 28-186 222
Plastic Emulsion. Lit 28-187 299
Plastic float valve, 15 mm dia. Each 28-188 252
Plastic shelf. Each 28-189 503
Plastic stud with reflector, 10 cm x 20 cm x 2 cm (Flush type). Each 28-190 550

Plastic stud with reflector, 10 cm x 7.5 cm x 2 cm (Raised Each 28-191 330


type).
Ply Wood 3 mm. Sqm 28-192 366
Poly extruded board 50 mm thick density 32-35 kg/m3. Sqm 28-193 833

Polyvinyl Distemper. Kg 28-194 111


Polythene sheet. Sqm 28-195 340
Push Plate CP. Each 28-196 251
Push Plate Brass. Each 28-197 402
POP Tiles (600 x 600 x 20 mm) (any Design). Sqm 28-198 574
PVC 5C twin Hollow or Single Hollow corrugated sheet/ Sqm 28-199 2313.4
roofing coated weighing not less than 5.38 Kg / Sqm except
framing all as specified.
PVC 5C twin Hollow or Single Hollow corrugated sheet/ Sqm 28-200 3766
roofing coated weighing not less than 4.842 Kg / Sqm except
framing all as specified.
PVC floor plain Tiles, 5 mm thick. Sqm 28-201 1840
PVC floor plain Tiles, 3 mm thick. Sqm 28-202 1029
PVC floor plain Tiles, 2 mm thick. Sqm 28-203 758
PVC floor plain Sheet, 3 mm thick. Sqm 28-204 1711
PVC floor plain Sheet, 2 mm thick. Sqm 28-205 1157
PVC plain sheet, 2 mm thick embedded except framing. Sqm 28-206 1818.44
PVC Sheet 1.5 Fibre Glass Ceiling / Panelling, 1200 mm x 600 Sqm 28-207 1689
mm.
Quick Rubber Based Runway Marking Paint. Ltr 28-208 453
Rawal plug with screw. Each 28-209 7
Rubber ring uPVC soil and waste pipe, 50 mm. Each 28-210 40
Rubber ring uPVC soil and waste pipe, 75 mm. Each 28-211 62
Rubber ring uPVC soil and waste pipe, 110 mm. Each 28-212 94
Rubber ring uPVC soil and waste pipe, 160 mm. Each 28-213 137
Rubber ring Gasket, 300 mm. Each 28-214 38
Rubber ring Gasket, 375 mm. Each 28-215 48
Rubber ring Gasket, 450 mm. Each 28-216 53
Rubber ring Gasket, 525 mm. Each 28-217 57
Rubber ring Gasket, 600 mm. Each 28-218 57
Rubber ring Gasket, 675 mm. Each 28-219 60
Rubber ring Gasket, 750 mm. Each 28-220 60
Rubber ring Gasket, 825 mm. Each 28-221 60
Rubber ring Gasket, 900 mm. Each 28-222 65
Rubber ring Gasket, 1050 mm. Each 28-223 65
Rubber ring Gasket, 1200 mm. Each 28-224 72
Sand (washed). Cum 28-225 890
Sheesham Ply, 3 mm. Sqm 28-226 379
Soft Board. Sqm 28-227 465
Shower Rose, CP. Each 28-228 604
Single Lever Basin Mixer, Standard Quality. Each 28-229 4732
Single Lever Basin Mixer, Deluxe Quality. Each 28-230 5685
Single Lever Basin Mixer, Premium Quality. Each 28-231 7996
Sink Mixer, Standard Quality. Each 28-232 6200
Sink Mixer, Deluxe Quality. Each 28-233 9460
Sink Mixer, Premium Quality. Each 28-234 14558
Sink Scullery of Stainless Steel with Double Drainage Board Each 28-235 8351
with Single Bowl upto 6000 Sqcm.
Sink Scullery of Stainless Steel with Single Drainage Board Each 28-236 5061
upto 6000 Sqcm.
Sink Scullery of Stainless Steel with Single Drainage Board Each 28-237 6037
with Double Bowl exceeding 6000 Sqcm upto 7500 Sqcm.

Sink Stainless Steel with Double Drainage Board and Double Each 28-238 9861
Bowl exceeding 6000 Sqcm upto 9300 Sqcm.
Sink waste coupling. Each 28-239 252
Sliding Bolt (Brass), 300 mm long. Each 28-240 1207
Sliding Bolt (Brass), 450 mm long. Each 28-241 1590
Sliding Bolt (CP), 300 mm long. Each 28-242 322
Sliding Bolt (CP), 450 mm long. Each 28-243 584
Soap tray. Each 28-244 312
1st Class Soft wood, Deodar. Cum 28-245 141500
Soil Aggregates, 40 mm to 50 mm. Cum 28-246 1324
Speed Breaker plastic 350 mm x 500 mm x 50 mm with Mtr 28-247 13500
reflectorized metal.
Speed Breaker plastic 350 mm x 500 mm x 50 mm with Mtr 28-248 6500
reflectorized PPM rubber.
Speed Breaker plastic 350 mm x 500 mm x 50 mm. Mtr 28-249 8500
Steel Chowkat, 16 gauge. Kg 28-250 150
Steel Chowkat, 18 gauge. Kg 28-251 146
Steel corrugated galvanized sheeting, 20 gauge of any Tonne 28-252 146900
standard size.
Steel corrugated galvanized sheeting, 22 gauge of any Tonne 28-253 151844
standard size.
Steel corrugated galvanized sheeting, 24 gauge of any Tonne 28-254 152210
standard size.
Steel Galvanised Sheets, 18 gauge. Sqm 28-255 1513
Steel Galvanised Sheets, 20 gauge. Sqm 28-256 1228
Steel Galvanised Sheets, 22 gauge. Sqm 28-257 1028
Steel Galvanised Sheets, 24 gauge in walls floor ceiling. Sqm 28-258 835
Stone dust (Khaka). Cum 28-259 1103
Stones, Random Rubble, Roughly dressed. Cum 28-260 1059
Synthetic vinyl (PVC) flexible membrane, 0.25 mm thick. Sqm 28-261 258

Synthetic vinyl (PVC) flexible membrane, 0.5 mm thick. Sqm 28-262 516
Synthetic vinyl (PVC) flexible membrane, 1.0 mm thick. Sqm 28-263 1046
Synthetic vinyl (PVC) flexible membrane, 2.0 mm thick. Sqm 28-264 1821
Tee Stop cock CP. Each 28-265 684
Termite Proofing Chemical. Ltr 28-266 4800
Thermopore Tiles, 600 mm x 600 mm x 20 mm. Sqm 28-267 323
Tiles (Glazed / Non-skid / Matt), Standard quality not Sqm 28-268 1890
exceeding 1600 sq cm
Tiles (Glazed / Non-skid / Matt), Deluxe quality exceeding Sqm 28-269 2529
1600 sq cm but not 3700 sq cm.
Tiles (Glazed / Non-skid / Matt), Premium quality exceeding Sqm 28-270 2860
3700 sq cm.
Tiles Granite 20 mm thick, Standard Quality. Sqm 28-271 2727
Tiles Granite 20 mm thick, Deluxe Quality. Sqm 28-272 5023
Tiles Granite 20 mm thick, Premium Quality. Sqm 28-273 7727
Tiles Marble 13 mm thick, Standard Quality. Sqm 28-274 630
Tiles Marble 20 mm thick, Standard Quality. Sqm 28-275 2338
Tiles Marble 13 mm thick, Deluxe Quality. Sqm 28-276 1236
Tiles Marble 20 mm thick, Deluxe Quality. Sqm 28-277 4876
Tiles Marble 13 mm thick, Premium Quality. Sqm 28-278 5005
Tiles Marble 20 mm thick, Premium Quality. Sqm 28-279 12110
Tiles Mosaic 300 x 300 x 25 mm of ordinary cement. Each 28-280 65
Tiles Mosaic 300 x 300 x 25 mm of white cement. Each 28-281 76
Toilet paper holder, Plastic. Each 28-282 497
Toilet shower, 15 mm dia. Each 28-283 1107
Torch Bonding Bituminous membrane, 3 mm thick. Sqm 28-284 851
Torch Bonding Bituminous membrane, 4 mm thick. Sqm 28-285 1069
Towel Rail CP, Double rod. Each 28-286 1107
Towel Rail CP, Single rod. Each 28-287 996
Teak Ply, 3 mm thick. Sqm 28-288 410
U bolts, 10 mm dia. C.No 28-289 28
uPVC Door Handle. Each 28-290 805
uPVC Door Hinges 2D. Each 28-291 895
uPVC Door Lock. Each 28-292 4025
uPVC soil and waste pipe, 200 mm. Meter 28-293 1211
uPVC soil and waste pipe, 300 mm. Meter 28-294 1868
uPVC P Trap, 75 mm. Each 28-295 243
uPVC P Trap, 100 mm. Each 28-296 366
uPVC Floor Trap, 100 mm. Each 28-297 515
Urinal Basin. Each 28-298 4126
Vanity Bowel. Each 28-299 4528
Venetian Blind, Horizontal, having metallic, plastic strip upto Sft 28-300 166
25 mm width.
Venetian Blind, Vertical, having fabric strip upto 90 mm Sft 28-301 282
width.
Venetian Blind, Vertical having fabric strip width exceeding 90 Sft 28-302 312
mm width upto 127 mm.
Venation Blind,Horizontal, having wooden strip. Sft 28-303 332
W.C Asiatic Pattern with Plastic Flushing tank. Each 28-304 4254
W.C Closet Pan European pattern. Each 28-305 2516
W.C Closet with Cistern any Colour with Seat Cover (non- Each 28-306 6591
coupled).
Wall Paper. Sqm 28-307 1000
Wall Shower, Standard Quality. Each 28-308 11180
Wall Shower, Deluxe Quality. Each 28-309 15460
Wall Shower, Premium Quality. Each 28-310 21822
Wash Hand Basin (WHB), Standard Quality. Each 28-311 5680
Wash Hand Basin (WHB), Deluxe Quality. Each 28-312 7500
Wash Hand Basin (WHB), Premium Quality. Each 28-313 9985
Wash Hand Basin (WHB), Glazed. Each 28-314 2666
Waste coupling. Each 28-315 252
Waste Pipe PVC. Each 28-316 100
Water bound macadam. Cum 28-317 1324
Water Closet (WC), European pattern (coupled), Standard Each 28-318 10500
Quality.
Water Closet (WC), European pattern (coupled), Deluxe Each 28-319 13150
Quality.
Water Closet (WC), European pattern (coupled), Premium Each 28-320 18190
Quality.
Water Proofing textile geo membrane, 0.25 mm thick. Sqm 28-321 402
Water stopper PVC, 225 mm wide, 5 mm thick. Mtr 28-322 656
Water stopper PVC, 225 mm wide, 8 mm thick. Mtr 28-323 1148
Water stopper PVC, 250 mm wide, 10 mm thick. Mtr 28-324 1641
Water stopper PVC, 250 mm wide, 12 mm thick. Mtr 28-325 1805
WC wall mounted. Each 28-326 12542
Wire Plain galvanized, 8 SWG. Metre 28-327 20
Wire Plain galvanized, 12 SWG. Metre 28-328 12
Wire Plain galvanized, 14 SWG. Metre 28-329 8
Wire Plain galvanized, 16 SWG. Metre 28-330 7
Wire Gauze 9x9 mesh, 24 Gauge. Sqm 28-331 660
Wire Gauze Aluminium16 x 16 mesh, 26 Gauge. Sqm 28-332 552
Wire Gauze iron Tinned 9 x 9 mesh, 22 Gauge. Sqm 28-333 747
Wire Gauze, Mosquito Proof, 16 x 16 mesh 26 gauge. Sqm 28-334 811
Wire Gauze, Mosquito Proof, 18 x 18 mesh 28 gauge. Sqm 28-335 171
Wire mattress, GI 100 mm x 100 mm. Sqm 28-336 800
Wire mattress, GI 150 mm x 150 mm. Sqm 28-337 650
Wire Netting Galvanised, 25 mm mesh, 14 SWG. Sqm 28-338 454
Wire Netting Galvanised, 25 mm x 25 mm mesh, 12 SWG. Sqm 28-339 639

Wire Netting Galvanised, 40 mm mesh, 14 SWG. Sqm 28-340 422


Wire Netting Galvanised, 40 mm x 40 mm mesh, 12 SWG. Sqm 28-341 455

Wire Netting Galvanised, 50 mm mesh, 14 SWG. Sqm 28-342 238


Wire Netting Galvanised, 50 mm x 50 mm mesh, 10 SWG. Sqm 28-343 320

Wire Netting Galvanised, 50 mm x 50 mm mesh, 12 SWG. Sqm 28-344 325

Wire Netting Galvanised, 75 mm x 75 mm mesh, 10 SWG. Sqm 28-345 303

Wire Netting Galvanised, 75 mm x 75 mm mesh, 12 SWG. Sqm 28-346 225

Wooden Laminated Tiles, 8 mm thick. Sqm 28-347 1515


Wooden Laminated Tiles, 12 mm thick. Sqm 28-348 3574
Water proof Drying System (WDS) Additive. Kg 28-349 520
6 Pieces Bath Set (Double Bib Cock and Toilet Shower etc.), Each 28-350 24000
Standard Quality.
6 Pieces Bath Set (Double Bib Cock and Toilet Shower etc.), Each 28-351 27400
Deluxe Quality.
6 Pieces Bath Set (Double Bib Cock and Toilet Shower etc.), Each 28-352 36000
Premium Quality.
7 Pieces Complete Bath Set, Standard Quality. Each 28-353 18600
7 Pieces Complete Bath Set, Deluxe Quality. Each 28-354 28730
7 Pieces Complete Bath Set, Premium Quality. Each 28-355 43540
Powerful Peopels make Places ''POWERFUL''
By: Sub Engr E&M Muhammad Imtiaz
THE END