Foundation, Trenches, Wells etc
Same as item 1-1, but in Rock not requiring blasting. Cum 1-3 2053
Same as item 1-1, but in Rock requiring blasting. Cum 1-4 1718
Same as item 1-1, but in Rock requiring blasting but blasting Cum 1-5 3501
is prohibited.
Add to item 1-1 to 1-05 for each additional 1.5 M lift or part Cum 1-6 225
thereof
Excavation over areas as in Ordinary/Hard Soil upto 1.5 M Cum 1-7 207
depth, in foundation / excavations, throw earth clear of
edges of excavation within 50 M.
Same as item 1-7 but 1.5 M to 3 M depth. Cum 1-8 404
Same as item 1-7 but 3 M and upto 6 M depth. Cum 1-9 448
Same as item 1-7 but 6 M and upto 9 M depth. Cum 1-10 477
Same as item 1-7 but 9 M and upto 12 M depth. Cum 1-11 527
Excavation over areas as in Rock upto 1.5 M depth, in Cum 1-12 1454
foundation / to obtain earth for filling under floors / areas
etc., or for shafts, wells exceeding 30 sqm each, throw earth
clear of edges of excavation within 50 M.
Same as item 1-12, but in Rock through blasting. Cum 1- 13 710
Same as item 1-12, but in Rock requiring blasting but blasting Cum 1-14 2824
prohibited.
Add to item 1-7 to 1-14 for each additional 1.5 M lift or part Cum 1-15 150
thereof
Earth Filling
Earth filling as in Ordinary or hard soil, filling in foundation, Cum 1-16 240
pipe trenches, shafts, wells, independent holes, under floors
or around plinths etc., 1.5 M below or above Ground Level
(GL), with spoil obtained from excavation in trenches/over
areas within 50M including watering and compaction in 150
mm layer and dressing to required profile and shape.
Add to item 01-16, for each additional 1.5 M or part thereof, Cum 1- 17 48
above / below GL.
Lead
Load "materials" (like excavated soil / rock, demolished brick Cum 1-18 339
bats, bricks, sand and bitumen etc.), by any means (specified
in items 1-1 to 1-15) upto 1000 M, unload and stack or
spread.
Add for carrying soil / rock demolished brick bats, bricks, sand Cum 1- 19 78
and bitumen etc.), by any means, for each subsequent 1000
M or part thereof (specified in items 1-1 to 1-15), unload and
stack or spread.
Miscellaneous
Excavate hill side slips, or similar loose material of any Cum 1- 20 286
description and remove to a distance not exceeding 25M and
deposit where directed, (loose or packed measure to be
converted into solid measure).
Finish the surface of existing embankments in repair to a neat Sqm 1- 21 11
and finished profile including making up where necessary,
(earth utilized from borrow pits for making up be paid for
extra).
Compaction / Ramming Earth in 150mm layers except Cum 1- 22 36
watering.
Compaction / Ramming Earth in 150mm layers with Cum 1-23 43
Watering.
Brick bats or other approved filling in soakage pits etc. Cum 1-24 6128
Taking out brick bats, boulders, rubbish etc, from Soakage Cum 1- 25 678
pits and dispose off as ordered (supply and filling of brick-
bats or other approved filling not included).
Pumping out water from excavation etc, including all labour, Cum 1-26 271
use of pumps, plants etc (The net quantity raised to be paid
for). The lift not to exceeding 12 M. Conversion Factor 1000
lit = one Cum.
Roads and Runways etc
Clearing and Grubbing, all as specified. Sqm 1-27 17
Compaction of Natural Ground upto 95% Modified AASHTO Sqm 1-28 12
density all as specified.
Same as item 1-28 but 93% Modified AASHTO density. Sqm 1-29 12
Same as item 1-28 but 90% Modified AASHTO density. Sqm 1-30 10
Making Embankment, with the specified /approved soil Cum 1-31 445
obtained from borrow excavation including Loading within
Five KM, compaction in 150mm layers upto 95% Modified
AASHTO density, and dressing to required profile and shape
as specified.
Same as item 1-31 but upto 93% Modified AASHTO density. Cum 1-32 374
Same as item 1-31 but 90% Modified AASHTO density. Cum 1-33 347
Cutting of ordinary / hard soil of roadway / Runway / Hard Cum 1-34 221
standing stripping etc, and dispose off / collect spoil within 5
KM, complete, all as specified.
Cutting of Rock not requiring blasting of roadway etc. and Cum 1-35 3123
dispose off / collect spoil within Five (5) KM , complete, all as
specified.
Same as item 1-35 but as in Rock requiring blasting. Cum 1-36 1606
Same as item 1-35 but as in Rock requiring blasting, but Cum 1-37 6342
blasting prohibited.
Add for carrying material obtained as specified in items 1-35 Cum 1-38 230
to 1-37, for each sub sequent Five(5) KM or part thereof.
Cut or fill in soft or hard soil not exceeding 150 mm, dry roll Sqm 2-6 11
and compact formation surface by power roller including
filling in depression with hard soil.
Compaction
Roll and compact, Granular Soil formation surface / Cum 2-7 77
embankments upto 150 mm layers, by compaction
equipment and roller upto 100% Modified AASHTO density,
including filling in depression with hard soil.
Roll and compact, Cohesive Soil formation Cum 2-8 75
surfaces/embankments upto 150 mm layer, by compaction
equipment and roller upto 95% Modified AASHTO density,
including filling in depression with hard soil.
Same as item No. 02-8, but 90% Modified AASHTO density. Cum 2-9 71
Roll and compact, Formation Surface, embankment upto 150 Cum 2-10 71
mm layers, by roller, including filling in depression, with hard
soil.
Bottoming /Sub Base
Bottoming /sub base of any thickness as specified using Soil Cum 2-11 2551
Aggregates of CBR 30%, laid and compacted to 100%
Modified AASHTO density by appropriate compaction
equipment and roller.
Same as item 2-11 but with Granular Sub Base material, all as Cum 2-12 2714
specified.
Bottoming /sub base of any thickness as specified using Soil Cum 2-13 2399
Aggregates of CBR 30%, compacted, including rolling by
appropriate compaction equipment and roller and filling in
depression.
Base Course
Water Bound Macadam (WBM), Base Course of CBR 100%, Cum 2-14 3146
any thickness as specified, laid and compacted to 100%
Modified AASHTO density by appropriate compaction
equipment and roller.
Aggregate Base Course, of any thickness as specified, laid and Cum 2-15 2840
compacted to 100% Modified AASHTO density, by
appropriate compaction equipment and roller.
Repairs
Scarifying WBM surface, by hand or by power, not exceeding Sqm 2-19 30
50 mm deep including removing not exceeding 50 M and
stacking for re-use.
Add to item 02-19, for every 25 mm or part thereof beyond Sqm 2-20 15
50 mm deep including removing not exceeding 50 M and
stacking for re-use.
Repair Pot-holes not exceeding one sqm each in surface of Sqm 2-21 724
roads by scarifying surfaces, cutting edges at least 25 mm
deep, sweeping free from dust and mud, coating surface with
Hot Dressing and filling with premix of crushed stones,
asphalt bitumen, and ramming it well.
Same as item 2-21 but by using with Asphalt cement, all as Sqm 2-22 741
specified.
Premix Carpet (Bit-Mac) On Asphaltic Surface
Providing and laying Premix Carpet of any thickness, Cum 2-23 21410
compacted on asphaltic surface, as specified, using asphalt
cement 60/70 or 80/100 and Broken / Crushed stone
including tack coat.
Premix Carpet (Bit-Mac) On WBM Surface
Providing and laying, Premix carpet of any thickness, Cum 2-24 22996
compacted on WBM surface, as specified, using asphalt
cement 60/70 or 80/100 and Broken or Crushed stone,
including prime coat.
Asphaltic Courses (Plant Mix)
Providing and laying, Asphaltic Base Course of any thickness, Ton 2-25 7485
as specified, with asphalt cement 60/70 or 80/100 using JMF
(except prime coat).
Providing and laying, Asphaltic Wearing Course of any Ton 2-26 8044
thickness, as specified, with asphalt cement 60/70 or 80/100,
using JMF (except tack coat).
Prime Coat / Tack Coat / Seal Coat
Prime Coat, on Base Course surface. Sqm 2-27 144
Tack Coat, on asphaltic surface. Sqm 2-28 77
Providing and laying Seal Coat using sand and asphalt Sqm 2-29 170
cement, all as specified.
Concrete – Roads, Hard Standings and Runways etc.
Providing and laying PCC with 4000 psi compressive Cum 2-30 13735
cylindrical strength all as specified in slabs for roads, hard
standings, etc., of any thickness, using Crushed stone,
including use and waste of form work (steel) and finishing
surface even and fair (not smooth).
Same as item 02-30, but PCC with 3000 psi compressive Cum 2-31 11845
cylindrical strength all as specified.
Providing Sand Cushion in layers as specified, under concrete Cum 2-32 1231
roads, hard standings and Runways etc.
Providing and Laying PQC Flexural Strength of 600 psi for Cum 2-33 17435
Runway, Taxiway Links, Lead-ins and Tarmac of any thickness
using Concrete Mix Design laid Manually all as specified.
Same as 2-33 but laid with fixed-form, mechanical paver, all Cum 2-34 22064
as Specified.
Same as 2-33 but laid with slip-form, mechanical paver, all as Cum 2-35 26661
Specified.
Wire Mattresses
Supply No 8 SWG, GI wire made up into mattress 100 x100 Sqm 2-36 979
mm mesh, fix and bind with 14 SWG wire (mattresses and
laps measured).
Same as item 02-36 but mattress 150 x 150 mm mesh. Sqm 2-37 799
Rapid Runway Repair
Lifting and placing of pre-cast RCC slabs, with a special lifting Sqm 2-38 772
beam including carriage as required, for Rapid Runway
Repairs.
Filling Sand between joints (3-6 mm thick) of pre-cast RCC Sqm 2-39 15
slabs for Rapid Runway Repairs and rolling with 6-8 ton roller
to make the surface perfectly level with adjacent surface.
Expansion Joints
Labour and necessary material for forming of Expansion joint Sqm 2-40 448
13 mm wide and leaving the joint clear for filling (length of
joint multiplied by thickness of joint). The filling of the joint
with requisite filler will be carried out by the specialists.
Providing and fixing, Expansion Cap 25 mm to 40 mm dia for Each 2-41 306
movement of dowels all as specified.
Speed Breakers / Studs
Providing and fixing Road speed Breaker with reflectorized Metre 2-42 10530
plastic, 350 mm wide and 50 mm high including end pieces
both sides complete with Bolts and plugs.
Same as 2-42 but with reflectorized EPM Rubber, all as Metre 2-43 8130
specified.
Same as 2-42 but with reflectorized Metal, all as specified. Metre 2-44 16530
Reflectorized Plastic Pavement Stud (10cm x 7.5 cm x 2 cm), Each 2-45 462
Raised type.
Same as 2-45 but having size (10 cm x 20 cm x 2 cm), Flush Each 2-46 726
type.
Same as 2-45 but Aluminum. Each 2-47 834
Jersey Barriers
Supply and Fix RCC pre-cast jersey barrier including lifting Metre 2-48 8793
and erection, all as specified.
Providing and laying new jersey barrier (PCC 4000 Psi), cast in Metre 2-49 4517
situ with slip form paver, all as specified.
Providing and laying of PCC with 3000 psi compressive Cum 3-5 8922
cylindrical strength in all non- structural elements except
formwork.
Same as item 3-5 including formwork and fair faces to Cum 3-6 10852
exposed surfaces.
Providing and laying of RCC with 3000 psi compressive Cum 3-7 10095
cylindrical strength in different structural elements
(foundation etc.) including form work all as specified.
Reinforcement measured and paid separately.
Same as item 3-7 except form work. Reinforcement Cum 3-8 8731
measured and paid separately.
Same as item 3-7 but in roof slabs, landings, walls, plinth Cum 3-9 13547
beams and bands etc. all as specified including form work
(reinforcement measured and paid separately).
Same as item 3-7 but columns, beams, stairs, posts, struts, Cum 3-10 13921
piers, lintels, and the like including form work, all as specified.
Reinforcement measured and paid separately.
Providing and laying of RCC with 3500 psi compressive Cum 3-11 15781
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.
Same as item 3-11 but in beams, columns, stairs, posts, Cum 3-12 16047
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-11 but in foundations, independent column Cum 3-13 12595
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.
Providing and laying of RCC with 4000 psi compressive Cum 3-14 16239
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.
Same as item 3-14 but in beams, columns, stairs, posts, Cum 3-15 16613
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-14 but in foundations, independent column Cum 3-16 13053
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.
Providing and laying of RCC with 5000 psi compressive Cum 3-17 16490
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.
Same as item 3-17 but in beams, columns, stairs, posts, Cum 3-18 16864
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-17 but in foundations, independent column Cum 3-19 13304
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.
Providing and laying of RCC with 6000 psi compressive Cum 3-20 17028
cylindrical strength all as specified in roof slabs, landings,
walls, plinth beams and bands, etc., including form work.
Reinforcement measured and paid separately.
Same as item 3-20 but in beams, columns, stairs, posts, Cum 3-21 17402
struts, piers, lintels and the like. Reinforcement measured
and paid separately.
Same as item 3-20 but in foundations, independent column Cum 3-22 13843
footings, and rigid floors etc. including form work as
specified. Reinforcement measured and paid separately.
Providing and fixing of PVC water stopper 250mm wide and Metre 3-23 2331
12 mm thick.
Same as 3-23 but 10 mm thick. Metre 3-24 2134
Same as 3-23 but 225 mm wide and 8 mm thick. Metre 3-25 1543
Same as 3-23 but 225 mm wide and 5 mm thick. Metre 3-26 952
Pre Cast Solid / Hollow Blocks
Providing and laying of PCC Solid Blocks for load bearing Cum 3-27 11188
walls as specified in building blocks walls including setting
and jointing in CM 1:6 upto Basement / GF roof level.
Same as item 3-27, but upto 1st floor roof level / Basement. Cum 3-28 11325
(1st lower ground level)
Same as item 3-27, but upto 2nd floor roof level / Basement. Cum 3-29 11462
(2nd lower ground level)
Providing and laying of PCC Solid Blocks for non - load Cum 3-30 10437
bearing walls as specified in building blocks walls including
setting and jointing in CM 1:6 upto GF roof level.
Same as item 3-30, but upto 1st floor roof level / Basement Cum 3-31 10725
(1st Lower Ground level).
Same as item 3-30, but upto 2nd floor roof level / Basement Cum 3-32 10711
(2nd Lower Ground level).
Providing and laying of PCC Hollow Blocks, for load bearing Cum 3-33 10868
walls, as specified in building blocks walls, including setting
and jointing in CM 1:6 upto Basement.
(1st Lower Ground) / GF roof level.
Same as item 03-33, but upto 1st floor roof level / Basement Cum 3-34 11005
st
(1 Lower Ground level).
Same as item 03-33, but upto 2nd floor roof level/ Basement Cum 3-35 11142
(2nd Lower Ground level).
Providing and laying of PCC Hollow Blocks, for non-load Cum 3-36 10112
bearing walls, as specified in building blocks walls, including
setting and jointing in CM 1:6 upto Basement / GF roof level
Same as item 03-36, but upto 1st floor roof level / Basement. Cum 3-37 10306
st
(1 lower ground level)
Same as item 03-36, but upto 2nd floor roof level / Cum 3-38 10386
Basement. (2nd lower ground level)
Pointing to PCC Solid / Hollow Blocks in CM (1:4). Sqm 3-39 171
Additional Labour Cost
Add labour cost for hoisting / lowering of concrete (Cast in Cum 3-40 118
situ) for each storey beyond 12 M above or below GL.
Same as item 03-40, but Pre-cast PCC Solid / Hollow blocks. Cum 3-41 186
RCC Jali
Supply and fix, 38mm thick Precast RCC jali, including setting Sqm 3-42 888
and jointing in CM 1:1, all as specified.
Same as item 03-42, but 50 mm thick. Sqm 3-43 1082
Same as item 03-42, but 75 mm thick. Sqm 3-44 1293
Fixing only of item 03- 42 to 03-44. Sqm 3-45 406
Add to item 03-42 to 03-45, if fixed in repair. Sqm 3-46 107
Kerb Stone
Providing and laying Precast PCC Kerb-stone, size 300 x 300 x Metre 3-47 473
150 mm including setting, jointing and pointing in CM 1:4 all
as specified.
Same as item 03-47, but size 350 × 300 × 150 mm. Metre 3-48 550
Same as item 03-47, but size 450 × 300 × 150 mm. Metre 3-49 574
Expansion Joints
Form expansion joint 13mm thick in RCC roof or floor slabs Sqm 3-50 2647
etc., and fill in with bitumen grade 10-20.
Supply and fix, Copper sheet 24 gauge in expansion joint Sqm 3-51 7116
(girth measurement).
Same as item 03-51, but using 26 gauge. Sqm 3-52 5825
Supply and fix, GI sheet 24 gauge in expansion joints (girth Sqm 3-53 5569
measurement).
Supply and fix Aluminium cover strip 60mm wide and 2mm Metre 3-54 342
thick with all fittings complete for all joints.
Same as above 3-54 but 100 mm wide. Metre 3-55 338
Same as item 03-54, but fixed in sections. Metre 3-56 617
Extra for lead beyond 10 Km to 15 Km or part thereof for Cum 3-57 260
weigh batch concrete.
Add to item 3-7 to 3-10, if crystalline water proofing chemical Cum 3-58 6336
material is added to cement at the rate of 2% by weight.
Add to item 3-11 to 3-13, if crystalline water proofing Cum 3-59 8064
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-14 to 3-16, if crystalline water proofing Cum 3-60 8218
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-17 to 3-19, if crystalline water proofing Cum 3-61 9120
chemical material is added to cement at the rate of 2% by
weight.
Add to item 3-20 to 3-22, if crystalline water proofing Cum 3-62 9216
chemical material is added to cement at the rate of 2% by
weight.
Facing with machine tiles built in CM(1:3) (228 x 114 x 43mm Sqm 4-59 3306
to 47mm thick)
Pointing to Brickwork
Pointing, flush or recessed in CM 1:3, to old or new brick Sqm 4-60 383
work, built in any mortar.
Same as item 04-60, but in CM 1:4. Sqm 4-61 377
Same as item 04-60, but in CM 1:6. Sqm 4-62 371
Tuck pointing, in CM 1:3, to old or new brick work, built in Sqm 4-63 436
any mortar.
Same as item 04-63, but in CM 1:4. Sqm 4-64 431
Same as item 04-63, but in CM 1:6. Sqm 4-65 425
Struck pointing, in CM 1:1, to old or new brick work, built in Sqm 4-66 479
any mortar.
Same as item 04-66, but in CM 1:2. Sqm 4-67 455
Racking out joints of old walls, built in any mortar, including Sqm 4-68 200
preparing surface for re-pointing.
Damp Proof Course (DPC)
13mm thick DPC of CM 1:3 mixed with approved water Sqm 4-69 449
resistant material 3% by weight.
Same as item 04-69, but 20 mm thick. Sqm 4-70 624
50mm thick P.C.C 1:2:4, using 3mm aggregate and finished Sqm 4-71 872
smooth with steel float, covered with two coats, each of hot
bitumen @ 0.75 kg per Sqm and blinded with 0.012 cum of
sand per Sqm.
Miscellaneous
Cutting out, in any mortar, and facing up with brick work in Sqm 4-72 1518
CM 1:3, where old walls had been binded in and removed.
Cutting out, Decayed brick work in any mortar, and re-facing Sqm 4-73 1745
with new bricks (any bond) in CM 1:3 and pointing/ striking in
same mortar 115 mm thick.
Brick Shuttering
Shuttering for slabs, landing, lintels, beams, columns and the Sqm 4-74 672
like etc.
Random Rubble stone masonry brought upto Courses, every Cum 5-1 3874
45 cm to 105 cm and 110 cm, roughly hammer dressed
stone, well bonded, faced with hammer dressed selected
stone, with square quoins and jambs, any thickness in
building work and laid dry.
Same as item 05-1, but laid and jointed in CM 1:4. Cum 5-2 6222
Same as item 05-1, but laid and jointed in CM 1:6. Cum 5-3 5880
Same as item 05-1, but in retaining wall. Cum 5-4 4311
Same as item 05-4, but laid and jointed in CM 1:4. Cum 5-5 6813
Same as item 05-4, but laid and jointed in CM 1:6. Cum 5-6 6471
Pointing
Pointing struck, flush or recessed to old or new stone Sqm 5-7 575
masonry, any type, in CM 1:3.
Same as item 05-7, but Coloured, CM 1:3. Sqm 5-8 618
Same as item 05-7, but in CM 1:4. Sqm 5-9 570
Same as item 05-9, but Coloured, CM 1:4. Sqm 5-10 606
Tuck pointing to old or new stone masonry, any type, in CM Sqm 5-11 581
1:3.
Same as item 05-11, but Coloured, CM 1:3. Sqm 5-12 620
Same as item 05-11, but in CM 1:4. Sqm 5-13 572
Same as item 05-13, but Coloured, CM 1:4. Sqm 5-14 608
Struck pointing to old or new stone masonry, any type, in CM Sqm 5-15 617
1:1.
Same as item 05-15, but Coloured, CM 1:1. Sqm 5-16 653
Dressed Stonework
Stone in blocks, with faces, beds and joints on One-Line Cum 5-17 9950
Dressed as in bands, string and plinth courses, blocking
courses pilaster, cornice, columns, caps, bases, copings,
kneelers, lintels etc., (measured net), built in CM 1:4.
Same as per item 05-17, but built in CM 1:6. Cum 5-18 9608
Boulders in Crates, Pitching, etc.
Boulder filling dry hand packed as filling behind retaining Cum 5-19 1734
walls in pitching and bunds.
Boulder filling in crates including laying readymade wire Cum 5-20 1914
mattress in position hand packing boulders folding wire
mattress and lying its edges so as to form crates of the
required shape and size etc. but excluding wire mattress and
anchorage of crates, which are to be paid separately.
Miscellaneous Repairs
Racking out Only, joints of stone masonry, in any mortar, Sqm 5-21 42
including preparation of surface for re-pointing, in any
mortar.
Refastening or re-securing, ends of balusters, newels, rag Each 5-22 100
bolts let into stone, re-cutting of mortices and re-running
with cement.
Boulders laid, jointed and pointed in CM 1:4 in pitching. Cum 5-23 6262
Supply and fix timber in scantling framed, 1st Class softwood Cum 6-3 203290
(Deodar), complete, all as specified.
Same as item 06-3, but 1st Class hardwood (Sheesham). Cum 6-4 144287
Supply and fix, timber in scantling wrought and framed, 1st Cum 6-5 203385
Class softwood (Deodar), complete.
Same as item 06-5, but 1st Class hardwood (Sheesham). Cum 6-6 146838
Fillets
Supply and fix, fillets not exceeding 12.90sqcm sectional area Metre 6-7 210
of 1st Class softwood (Deodar) wrought and fixed with
screws.
Same as item 06-7, but 1st Class hardwood (Sheesham). Metre 6-8 164
Supply and fix fillets exceeding 12.90 sqcm but not exceeding Metre 6-9 346
25.80 sqcm sectional area of 1st Class softwood (Deodar),
wrought and fixed with screws.
Same as item 06-9, but 1st Class hardwood (Sheesham). Metre 6-10 265
Supply and fix fillets exceeding 25.80 sqcm but not exceeding Metre 6-11 539
38.70 sqcm in sectional area of 1st Class softwood (Deodar),
wrought and fixed with screws.
Same as item 06-11, but 1st Class hardwood (Sheesham). Metre 6-12 396
Boarding
Supply and fix, chipboard (600 density), 13 mm thick. Sqm 6-13 700
Same as item 06-13, but 19 mm thick. Sqm 6-14 840
Same as item 06-13, but 25 mm thick. Sqm 6-15 1051
Supply and fix, ply wood 3 mm thick commercial ply in any Sqm 6-16 587
position.
Same as item 06-16, but Sheesham ply. Sqm 6-17 604
Same as item 06-16, but Teak ply. Sqm 6-18 643
Add to item 06-16, 06-17, and 06-18, if fixed in repairs. Sqm 6-19 66
Supply and fix 19 mm thick Chip board veneered both sides Sqm 6-20 1228
of specified pattern in any position Commercial.
Same as item 06-20, but Sheesham veneered. Sqm 6-21 1228
Same as item 06-20, but Teak veneered. Sqm 6-22 1291
Supply and fix 10 mm thick MDF laminated sheet of specified Sqm 6-23 923
pattern in any position.
Same as item 6-23 but 16 mm thick all as specified. Sqm 6-24 1367
Same as item 6-23 but 24 mm thick all as specified. Sqm 6-25 2158
Old Roof Trusses
Taking down, old timber trusses upto 8 M span. Each 6-26 1440
Same as item 06-26, but exceeding 8M, not exceeding 11 M Each 6-27 2100
span.
Hoisting and fixing old timber trusses upto 8 M span. Each 6-28 2820
Same as item 06-28, but exceeding 8M and not exceeding 11 Each 6-29 3480
M span.
Trellis Work
Supply and fix 40 mm x 10 mm first class soft wood (Deodar), Sqm 6-30 4558
wrought trellis work two way, square or diagonal at 50 mm
space and 75 mm x 25 mm fillet framing all around fixed,
complete.
Moulding and Turned work
Supply and fix 1st Class softwood (Deodar), moulding and Metre 6-31 600
turned work exceeding 75 mm but not exceeding 150 mm, 25
mm thick.
Same as item 06-31, but 40 mm thick. Metre 6-32 1060
Same as item 06-31, but 50 mm thick. Metre 6-33 1330
Workmanship, Plugging etc.
Labour only beads, chamfers, splay, rebate, rounded angles, Metre 6-34 198
tongues, grooves, rounded nosings, staff beads, flutes, each
exc. 6mm and not exceeding 75 mm width or girth,
mouldings and turned work not exceeding 75mm girth,
where not otherwise provided. Rate per 25 mm turned girth
or part thereof, 1st Class softwood (Deodar).
Same as item 06-34, but 1st Class hardwood (Sheesham). Metre 6-35 231
Supply and fix Rawal plug 25 mm long for boards etc. not Metre 6-36 85
exceeding 200 mm c/c (in any wall, in any mortar or
concrete)
Same as item 06-36, but 50mm long. Metre 6-37 86
Jobbing Work for all items in 1st Class soft wood (Deodar)/
hard wood (Sheesham)
Resecuring of wire gauze (fly and mosquito netting with fillet Sqm 6-38 114
and or framing), hard / soft wood.
Taking up or down and refixing of wire gauze (fly and Sqm 6-39 180
mosquito netting with fillet and / or framing), hard / soft
wood.
Taking up or down wire gauze (fly and mosquito netting with Sqm 6-40 66
fillets and / or framing) and removing to store, (hard / soft
wood).
Taking up or down and refixing of shelves including brackets, Sqm 6-41 213
fillets and window board with beads etc., (hard / soft wood).
Re-securing of casings (box) to pipes, any girth, (hard / soft Sqm 6-47 66
wood).
Taking up or down and refixing of casing (box) to pipes any Metre 6-48 132
girth, (hard / soft wood).
Taking up or down and removing to store of casing (box) to Metre 6-49 33
pipes any girth, (hard / soft wood).
Re-securing of fillets, mouldings, quadrant skirting, hand rails, Metre 6-50 72
peg rails, etc, (hard / soft wood).
Taking up and down and refixing of fillets, mouldings, Metre 6-51 105
quadrant skirting, hand rails, peg rails, etc., (hard / soft
wood).
Taking up or down fillets, moldings, quadrant skirting, hand Metre 6-52 33
rails, peg rails etc., and removing to store, (hard / soft wood).
Taking up or down and refixing of scantling in any position, Cum 6-53 9000
(hard / soft wood).
Deduct from item 7-7 and 7-8, if chowkat 1st Class Hardwood Sqm 7-11 4100
(Sheesham) not supplied and fixed.
Glazed / Gauzed Doors
Supply and fix, 1st Class Soft Wood (Deodar), Glazed doors, Sqm 7-12 12927
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with hinges or pivots
and mongery all as specified, 32 mm thick.
Same as item 7- 12, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-13 13211
Same as item 7-12, but 38 mm thick. Sqm 7-14 13280
Same as item 7-14, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-15 13224
Deduct from item 7-12 to 7-15, if chowkats not supplied and Sqm 7-16 7264
fixed.
Supply and fix, 1st Class Hard Wood (Ash wood), Glazed Sqm 7-17 18630
doors with moulded or chamfered bars, panels filled in with
glass including chowkats, holdfasts and hung with hinges or
pivots and mongery all as specified, 32 mm thick.
Same as item 7-17, but gauzed, 9x9 mesh, 24 BG. Sqm 7-18 18507
Same as item 7-17, but 38 mm thick. Sqm 7-19 19186
Same as item 7-19, but gauzed, 9x9 mesh 24 BG. Sqm 7-20 19156
Deduct from item 7-17 to 7-20, if chowkats not supplied and 7-21 10023
fixed.
Supply and fix, 1st Class Hard Wood (Mahogany), Glazed Sqm 7-22 17381
doors with moulded or chamfered bars, panels filled in with
glass including chowkats, holdfasts and hung with hinges or
pivots and mongery all as specified, 32 mm thick.
Same as item 7-22, but gauzed 9x9 mesh 24 gauge. Sqm 7-23 17339
Same as item 7- 22, but 38 mm thick. Sqm 7-24 18066
Same as item 7-24, but gauzed 9x9 mesh 24 BG. Sqm 7-25 18527
Deduct from item 7-22 to 7-25, if chowkats not supplied and Sqm 7-26 9854
fixed.
Supply and fix 1st class Hard Wood (Sheesham), Glazed doors Sqm 7-27 11855
with moulded or chamfered bars, angels filled in with glass
including chowkats, holdfasts hung with hinges or pivots and
mongery all as specified, 32 mm thick.
Same as item 7-27, but gauzed, 9X9 mesh, 24 BG. Sqm 7-28 11832
Same as item No 7-27, but 38 mm thick. Sqm 7-29 12532
Same as item 7-29, but gauzed, 9x9 mesh, 24 BG. Sqm 7-30 12511
Deduct from item 7-27 to 7- 30, if chowkats not supplied and Sqm 7-31 5410
fixed.
Deduct from item 7-13, 7-15, 7-18, 7-20, 7-23, 7-25, 7-28, Sqm 7-32 561
and 7-30, if mosquito proof gauze, 16 x 16 mesh, 26 gauge is
used.
Supply and fix, 1st Class Soft Wood (Deodar) Framed and Sqm 7-33 14086
Panelled doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fast and mongery, all as
specified, 32 mm thick.
Same as item 7-33, but 38 mm thick. Sqm 7-34 14161
Supply and fix, 1st Class Hard Wood (Ash wood), Framed and Sqm 7-35 18895
Panelled doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fasts, and monger, all as
specified, 32 mm thick.
Same as item 7-35, but 38 mm thick. Sqm 7-36 19483
Supply and fix, 1st Class Hard Wood (Mahogany) Framed and Sqm 7-37 18658
Panelled Doors, gates etc., panels filled with MDF 16 mm
sheet, including chowkats, hold fasts and mongery, all as
specified , 32 mm thick.
Same as item 7-37, but 38 mm thick. Sqm 7-38 19233
Deduct from item 7-33 and 7-34, if chowkat 1st Class Soft Sqm 7-39 4675
wood (Deodar) not supplied and fixed.
Deduct from item 7-35, 7-36, 7-37 and 7-38 if chowkat 1st Sqm 7-40 7099
Class Hardwood (Ashwood / Mahogany ) not supplied and
fixed.
Supply and fix, Solid Flush door, Teak veneered, 38 mm thick Sqm 7-41 13183
including mongery, without chowkats.
Same as item 7-41, but Sheesham veneered. Sqm 7-42 13104
Same as item 7-41, but Commercial veneered. Sqm 7-43 13072
Supply and fix, Solid Flush door, Teak veneered, 32 mm thick Sqm 7-44 11798
including mongery, without chowkats.
Same as item 7-44, but Sheesham veneered. Sqm 7-45 11720
Same as item 7-44, but Commercial veneered. Sqm 7-46 11687
Supply and fix, Solid Flush door, Teak veneered, 25 mm thick Sqm 7-47 10399
including mongery, without chowkats.
Same as item 7-47, but Sheesham veneered. Sqm 7-48 10321
Same as item 7-47, but Commercial veneered. Sqm 7-49 10288
Same as item 7-47 to 7-49 but Fixing only. Sqm 7-50 492
Add to item 7-47 to 7-50, if fixed in Repairs. Sqm 7-51 33
Supply and fix, Hollow Flush Door, Teak Veneered, 38 mm Sqm 7-52 9380
thick including mongery, all as specified, without chowkats.
Supply and fix Tubular Particle Board Engineered door, 38 Sqm 7-59 9324
mm thick including mongery, all as specified, without
chowkats.
Add to 7-41 to 7-49 and 7-52 to 7-59, if chowkat 1st Class Sqm 7-60 4675
Soft Wood (Deodar) supplied and fixed.
Aluminium Doors
Supply Aluminium Sliding Door, Deluxe Quality, of Anodized Sqm 7-61 8768
Aluminium extruded section in any size, colour and texture,
including fixing on concrete, wood or steel frames, complete
except glass, lock and handle.
Same as item 7-61 but Premium Quality, all as specified. Sqm 7-62 9368
Supply Aluminium Swing door, Single shutter, Deluxe Quality Sqm 7-63 8960
of Anodized Aluminium extruded section in any size, colour
and texture as specified including fixing on concrete, wooden
or steel frames, complete except glass, lock and handle.
Same as item 7-63 but Premium Quality, all as specified. Sqm 7-64 10112
Supply Aluminium Swing door, Double shutter, Deluxe Quality Sqm 7-65 9428
of Anodized Aluminium extruded section in any size, colour
and texture as specified including fixing on concrete, wooden
or steel frames, complete except glass, lock and handle.
Same as item 7-65 but Premium Quality, all as specified. Sqm 7-66 10328
Fixing only, Aluminium door any type on concrete, wooden or Sqm 7-67 495
steel frames, complete, except glass, lock and handle.
uPVC Doors
Supply and fix, uPVC Sliding Door, 37 mm thick shutter with Sqm 7-68 10372
frame 80mm x 50mm exceeding 3.5 sqm each in white colour
including all necessary fittings, mongery, fly proof netting
except glass, complete all as specified.
Same as item 7-68, but coloured. Sqm 7-69 18377
Supply and fix, uPVC Door, 60 mm thick shutter for full glass Sqm 7-70 15286
with frame complete exceeding 1.9 sqm each, in white colour
including necessary fittings, mongery except glass, complete
all as specified.
Same as item 7-70, but coloured. Sqm 7-71 16935
Same as item 7-70, but with groove panel 20 mm thick, filled Sqm 7-72 21164
instead of glass, as specified complete in white colour.
Same as item 7-80, but 342 mm wall, (Single/Double Leaf). Metre 7-82 1729
Deduct from item 7-86 to 7-89, if chowkats not supplied and 7-90 7250
fixed.
Supply and fix, 1st Class Hard wood (Sheesham), wrought, Sqm 7-91 10716
sashes, glazed with moulded or chamfered bars, panels filled
in with glass including chowkats, holdfasts and fixed with
screws to frames, 32 mm thick.
Same as item 7-91, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-92 10981
Same as item 7-91, but 38 mm thick, glazed. Sqm 7-93 10716
Same as item 7-93, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-94 10693
Deduct from item 7-91 to 7-94, if chowkats not supplied and Sqm 7-95 5410
fixed.
Supply and fix, 1st class Soft wood (Deodar), CSWs glazed, Sqm 7-96 15605
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with pivots and
mongery all as specified, 32 mm thick.
Same as item 7-96, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-97 15588
Same as item 7-96, but 38 mm thick. Sqm 7-98 15875
Same as item 7-98, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-99 15926
Deduct from item 7-96 to 7-99, if chowkats not supplied and Sqm 7-100 10924
fixed.
Supply and fix, 1st class Hard wood (Sheesham), CSWs glazed Sqm 7-101 11217
with moulded or chamfered bars, panels filled in with glass
including chowkats, holdfasts and hung with pivots and
mongery all as specified, 32 mm thick.
Same as item 7-101, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-102 11200
Same as item 7-101, but 38 mm thick. Sqm 7-103 11486
Same as item 7-103, but gauzed, 9x9 mesh, 24 gauge. Sqm 7-104 11395
Deduct from item 7-101 to 7-104, if chowkats not supplied Sqm 7-105 7048
and fixed.
Deduct from item 7-97, 7-99, 7-102 and 7-104, if mosquito Sqm 7-106 409
proof gauze is used.
Supply and fix, Venetian shutter for windows made of 1st Sqm 7-107 13512
class Soft wood (Deodar), 100 mm wide rail and styles and
Hard wood (Sheesham) Venetian, including chowkats 75 mm
x 125 mm, holdfasts and fixed with screws to frame, 32 mm
thick.
Same as item 7-107, but 38 mm thick. Sqm 7-108 14301
Deduct from item 7-107 and 7-108, if chowkats 1st class Soft Sqm 7-109 6325
wood (Deodar) not supplied and fixed.
Aluminium Windows
Supply of Aluminium Sliding window, Deluxe Quality, of Sqm 7-110 8567
Anodized Aluminium extruded section in any size, colour and
texture as specified, including fixing on concrete, wood or
steel frames, complete with all necessary fittings except glass.
Supply and fix, Box Pipe type open-able and fixed side-hung Sqm 7-117 7289
window or CSW using 16 gauge frame section 50mm x 25mm
and panel Z shape 38 mm x 31 mm x 38 mm and 10mm x
10mm square gola, not exceeding 1.48 Sqm each, with all
necessary fittings/mongery, hold fast etc. and two coats of SE
paint in addition to one coat of primer / rust proof paint,
except wire gauze and glass panes and grill.
Same as item 7-117 but exceeding 1.48 Sqm, all as specified. Sqm 7-118 7287
uPVC Windows
Supply and fix uPVC sliding window in white colour 37 mm Sqm 7-119 10843
thick shutter with , frame 80 mm x 50 mm complete
exceeding 2.23 Sqm each in white colour including necessary
fittings, mongery, fly proof netting, except glass.
Same as item 7-129 but 38 mm thick all as specified. Sqm 7-130 11357
Supply and fix,1st Class Hard wood (Mohagany), framed and Sqm 7-131 10466
panelled partition and dados 32 mm thick, all as specified.
Same as item 7-131 but 38 mm thick all as specified. Sqm 7-132 11189
Supply and fix,12mm thick Plate Glass partition/door in any Sqm 7-133 10316
size including all necessary accessories i.e. pivot machine,
handle lock etc.
Kitchen Cabinets
Supply and fix, Kitchen Floor / Sink Floor Cabinet, 600 mm Metre 7-134 14209
wide and 862 mm high with First Class Soft wood (Deodar)
frame, 19 mm thick Teak Veneered board shutter, drawers
including all necessary Chromium plated (CP) mongery, RCC
slab, 25 mm thick white / coloured marble slab, complete as
per IS Arch 17,18 and 19.
Supply and fix, Kitchen Wall Cabinet 381mm wide and 610 Metre 7-135 7596
mm high, 19 mm thick Teak Veneered board shutter
complete as per IS Arch 17, 18 and 19, including all necessary
CP monger, fixture and deodar wood edging provided to door
cabinets.
Supply and fix, Kitchen Exhaust Hood made of Teak Veneered Metre 7-136 6721
board with 22BG, PGI sheet fixed on inner side complete as
per Information Sheet IS Arch No 17, 18 and 19, including all
fitting / fixture as specified.
Venetian Blinds
Supply and fix, Venetian blinds (Horizontal) having metallic, Sqm 7-137 2193
plastic strip, upto 25mm width, complete with all accessories.
Supply and fix, Venetian blind (Vertical) having fabric strip, Sqm 7-138 3691
upto 90 mm width, of desired shades, complete with all
accessories.
Same as item 7-138, but strip width exceeding 90mm upto Sqm 7-139 4078
127 mm.
Supply any fix, Venetian blinds (horizontal) having wooden Sqm 7-140 4338
strip, complete with all accessories.
Wire Gauze
Supply Iron tinned wire gauze fly proof 9x9 mesh, 24 gauge Sqm 7-141 1435
and fixed with cover fillets to window chowkats etc.
Same as item 7-161, but refixing in other opening. Each 7-162 523
Taking down window chowkats including window boards, if Each 7-163 105
any, (Hard/Soft wood).
Removing to or from store window chowkats including Each 7-164 69
window boards, if any, (Hard/Soft wood).
Re-securing without taking down window chowkats including Each 7-165 175
Sashes (Hard/Soft wood).
Taking down window chowkats including sashes (Hard/Soft Each 7-166 415
wood) and re-fixing in same opening.
Same as item 7-166, but re-fixing in other opening. Each 7-167 601
Taking down window chowkats, including sashes (Hard/Soft Each 7-168 62
wood).
Removing to or from store, window chowkats including Each 7-169 40
sashes (Hard/Soft wood).
Re-securing without taking down casement window fanlights Each 7-170 122
etc. (sashes only) (Hard/Soft wood).
Taking down casement, window, fanlights etc. (sashes only) Each 7-171 229
(Hard/Soft wood) and re-fixing same opening.
Same as item 7-171, but re-fixing in other openings. Each 7-172 275
Taking down casement, windows, fanlights etc. (sashes only), Each 7-173 53
Hard /Soft wood.
Removing to or from store, casement, window, fanlights etc. Each 7-174 20
(sashes only) Hard/ Soft wood.
Re-securing without taking down door chowkats (not Each 7-175 249
exceeding 2.60 m each) including architraves if any,
(Hard/Soft wood).
Taking down door chowkats (not exceeding 2.60 m each) Each 7-176 415
including architraves if any, Hard/Soft wood and refixing in
same opening.
Same as item 7-176, but re-fixing in other opening. Each 7-177 506
Taking down door chowkats (not exceeding 2.60 m each) Each 7-178 125
including architraves, if any, Hard/Soft wood.
Removing to or from store door chowkats (not exceeding Each 7-179 50
2.60 m super each) incl architraves, if any, Hard/Soft wood.
Re-securing without taking down door chowkats (exceeding Each 7-180 436
2.60m each) including architraves if any, Hard/Soft wood.
Taking down door chowkats (exceeding 2.60m each) Each 7-181 601
including architraves if any, Hard / Soft wood and re-fixing in
same opening.
Same as item 7-181, but re-fixing in other opening. Each 7-182 634
Taking down door chowkats (exceeding 2.60 m each) Each 7-183 270
including architraves if any, Hard /Soft wood.
Removing to or from store, door chowkats (exceeding 2.60 m Each 7-184 83
each) including architraves if any, Hard /Soft wood.
Re-securing without taking down door or gates, leaves only Each 7-185 56
(single or folding) of any pattern or thickness not exceeding
2.60 m each, Hard /Soft wood.
Taking down door or gates, leaves only (single or folding) of Each 7-186 146
any pattern or thickness not exceeding 2.60 m each, Hard /
Soft wood and re-fixing in same opening.
Same as item 7-186, but re-fixing in the other opening. Each 7-187 201
Taking down door or gates, leaves only (single or folding) of Each 7-188 55
any pattern or thickness not exceeding 2.60 m each.
Removing to or from store door or gates, leaves only (single Each 7-189 30
or folding) of any pattern or thickness exceeding 2.60 m
each. Hard / Soft wood.
Re-securing without taking down partitions, framing, Sqm 7-190 125
cupboard front, wall panelling and similar woodwork,
including doors exceeding 2.60 m each, Hard / Soft wood.
Taking down partitions, framing, cupboard front, wall Sqm 7-191 435
panelling and similar woodwork, including doors exceeding
2.60 m each Hard / Soft wood and re-fixing in same opening.
Same as item 7-191, but re-fixing in other opening. Sqm 7-192 1058
Taking down partitions, framing, cupboard front, wall Sqm 7-193 259
panelling and similar woodwork, including doors exceeding
2.60 m each, Hard / Soft wood.
Removing to or from store, partitions, framing, cupboard Sqm 7-194 240
front, wall panelling and similar woodwork, including doors
exceeding 2.60 m each, Hard / Soft wood.
Door or gates (any description) cramped up, reweighed with Each 7-195 666
new wedges in glue (or white lead repined if in external work)
not exceeding 2.60 m each, including taking down and re-
hanging, taking off and re-fixing hinges (any description) and
removing to and from workshop.
Same as item 7-195, but exceeding 2.60 m each. Each 7-196 691
Door or gates (any description) cramped up, reweighed with Each 7-197 728
new wedges in glue (or white lead repined if in external work)
not exceeding 2.60 m each, including taking down and re-
hanging, taking off and re-fixing hinges (any description) and
renewal of defective parts and removing to and from
workshop.
Same as item 7-197, but exceeding 2.60 m each. Each 7-198 1047
Same as item 8-83 to 8-86, but fixing only. Each 8-87 195
Add to item 8-83 to 8-87, if fixed in repairs. Each 8-88 42
Locks (Cupboards)
Supply and fix, CP locks for cupboard 50 mm, complete. Each 8-89 154
Supply and fix, Brass locks for cupboard 50 mm, complete. Each 8-90 266
Supply and fix of 25 mm dia stainless steel pipe with any Metre 8-182 240
colour, design and texture fancy type for curtains with
brackets, ends, hooks etc. complete.
Same as item 8-181 to 8-182, but fixing only. Each 8-183 83
Add to item 8-181 to 8-183, if fixed in repairs. Each 8-184 50
Supply and fix, brackets strong cast Brass for curtain poles of Pair 8-185 785
any dia.
Same as item 8-185, but fixing only. Pair 8-186 90
Add to item 8-185 or 8-186, if fixed in repairs. Pair 8-187 42
Supply and fix Ring type curtain rods with suitable brackets Metre 8-188 203
and end fittings, complete all as specified.
Push and Kick Plates
Supply and fix, Brass or Copper push plate exceeding 160 Each 8-189 544
sqcm in area (16-18 gauge).
Same as item 8-189, but Stainless steel. Each 8-190 364
Same as item 8-189, but CP. Each 8-191 362
Same as item 8-189 to 8-191, but fixing only. Each 8-192 61
Add to item 8-189 to 8-192, if fixed in repairs. Each 8-193 25
Supply and fix, Brass or Copper kick plate (16-18 gauge). Sqm 8-194 9931
Supply and fix Aluminium door Handle, Anodized bronze in Each 8-208 525
any design and pattern.
Supply and fix uPVC door hinges, all as specified. Each 8-209 4431
Supply and fix uPVC door handle, all as specified. Each 8-210 1058
Supply and fix uPVC door lock, all as specified. Each 8-211 5025
Door Stopper/Linings
Supply and fix, rubber linings to door with screw etc. Metre 8-212 134
Supply and fix, Magnetic door stopper on wall or floor of any Each 8-213 202
type.
Same as item 9-25, but weighting 1 Kg and over, upto 3 Kg. Kg 9-26 255
Same as item 9-36, but length exceeding 75mm and not Each 9-37 83
exceeding 150mm.
Same as item 9-36, but length exceeding 150mm and not Each 9-38 114
exceeding 300mm.
Same as item 9-36 or 9-37 and 9-38, but fixing only. Each 9-39 7
Add to item 9-36 to 9-39, if fixed in repairs. Each 9-40 4
Supply and fix, bolts exceeding 18mm but not exceeding 25 Each 9-41 132
mm dia and length not exceeding 75mm with hexagon,
square, cup or cheese heads, screwed one or lewised each
with one washer and one hexagon/square nut.
Same as item 9-41, but length exceeding 75mm and not Each 9-42 216
exceeding 150mm.
Same as item 9-41, but length exceeding 150 mm and not Each 9-43 276
exceeding 300mm.
Same as item 9-41or 09-42 and 09-43, but fixing only. Each 9-44 11
Add to item 9-41 to 9-44, if fixed in repairs. Each 9-45 7
Galvanizing
Galvanizing light articles (weight not exceeding 3 Kg each). Kg 9-46 45
Galvanizing, iron/ steel work (not elsewhere provided) any Sqm 9-47 277
description, area galvanized measure flat (not girths).
Steel Reinforcement
Supply and fix, bars round, square or flat including cutting, Kg 9-52 146
bending, binding and placing reinforcement in position.
Supply and fix, XPM (expended metal), 38 mm x 44 mm mesh Sqm 9-63 368
(18 gauge) BRC fabric weld-mesh, max-weld etc., in
reinforcement or in other positions like doors, partition and
lathing for plaster, to shape and size as required, including
binding with 14 SWG wire, nails staples etc., and placing in
position, measured net.
Same as item 9-63, but 25 mm x 25 mm mesh. Sqm 9-64 504
Same as item 9-63 but (16 gauge). Sqm 9-65 449
Same as item 9-65 but 25 mm x 25 mm mesh. Sqm 9-66 613
Same as item 9-65 or 9-66, but except cost of fabric etc. Sqm 9-67 95
Plain Sheeting
Supply and fix, GI sheets, 24 BG in walls, floors, ceiling etc. Sqm 9-68 1197
Supply and fix, Wire Netting, Iron galvanized 75 mm x 75 mm Sqm 9-100 383
mesh, 12 SWG and fixed with tinned tacks, G.I staples etc., as
required.
Same as item 9-100 but 50 mm x 50 mm mesh as specified. Sqm 9-101 449
Supply and fix, Wire Netting, Iron galvanized 75 mm x 75 mm Sqm 9-104 481
mesh, 10 SWG and fixed with tinned tacks, G.I staples etc., all
as required.
Same as item 9-104 but 50 mm x 50 mm of mesh as Sqm 9-105 443
specified.
Same as item 9-97 to 9-105, but fixing only. Sqm 9-106 40
Add item 9-97 or 9-106, if fixed in repair. Sqm 9-107 24
Concertina / Razor Wire
Supply and fix, Concertina Wire / Razor wire, single coil, 12 Metre 9-108 482
gauge galvanized wire, loop dia 0.452 to 0.990M, complete,
all as specified.
Same as item 9-108, but fixing only. Metre 9-109 6
Same as item 9-108 and 9-109, if fixed in repairs. Metre 9-110 4
MS Hollow pipe
Supply and fix 1”x1”, MS hollow pipe square, 16 gauge Metre 9-111 387
including welding/ jointing etc.
Same as item 9-111 but 1 ¼”x1 ¼”, all as specified. Metre 9-112 540
Same as item 9-111 but 1 ½”x1 ½”, all as specified. Metre 9-113 616
Same as item 9-111 but 2” x 2”, all as specified. Metre 9-114 700
Same as item 9-111 but 3”x3”, all as specified. Metre 9-115 1313
Supply and fix 1”x1”, MS hollow pipe square, 18 gauge Metre 9-116 424
including welding/ jointing etc.
Same as item 9-116 but 1 ¼”x1 ¼”, all as specified. Metre 9-117 464
Same as item 9-116 but 1 ½”x1 ½”, all as specified. Metre 9-118 530
Same as item 9-116 but 2” x 2”, all as specified. Metre 9-119 588
Same as item 9-116 but 3”x3”, all as specified. Metre 9-120 855
Supply and fix, 1 ½"x 1” MS hollow pipe rectangular, 16 gauge Metre 9-121 565
including welding/ jointing etc.
Same as item 9-121 but 2”x 1 ½", all as specified. Metre 9-122 686
Supply and fix, 1 ½"x 1” MS hollow pipe rectangular, 18 gauge Metre 9-123 488
including welding/ jointing etc.
Same as item 9-123 but 2”x 1 ½", all as specified. Metre 9-124 588
Stainless Steel Hand Railing
Supply and fix, Stainless steel Hand railing using ¾" to 2" Metre 9-125 3639
dia,16 to 18 Gauge pipe with all fittings etc. as per
specifications.
Same as item 10-10 but 22 BG, all as specified. Sqm 10-11 1625
Same as item 10-10 to 10-11, but except cost of sheets. Sqm 10-12 250
Extra, for bolting, end laps, each corrugation. Sqm 10-21 287
Sloping Pattern Roofs
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-22 2272
complete in all respects with nails, screws, clips etc., in
Sloping pattern roofs, with rolled side joints, plain, 150mm
end laps etc., including wooden battens, 40mm x 50mm for
roll.
Same as item 10-22 but 22 BG, all as specified. Sqm 10-23 2568
Same as item 10-22 to 10-23, but except cost of sheets. Sqm 10-24 840
Supply and fix, corrugated galvanized steel sheet 24 BG, fixed Sqm 10-25 2229
complete in all respects with nails, screws, clips etc., in
Sloping pattern roofs, with rolled side joints, plain, without
end laps, sheets, ridges, hips, valley, gutters etc.
Same as item 10-25 but 22 BG, all as specified. Sqm 10-26 2524
Same as item 10-25 to 10-26, but except cost of sheets. Sqm 10-27 833
Same as item 10-28 but 22 BG, all as specified. Sqm 10-29 2595
Same as item 10-28 to 10-29 but except cost of sheets. Sqm 10-30 889
Supply and fix, Plain galvanized steel sheet 24 BG in ridges Sqm 10-31 1691
hips, valleys and straight and stepped flashing, roof plates
and sleeve pieces etc., without wooden battens as required.
Same as item 10-31 but 22 BG, all as specified. Sqm 10-32 2017
Same as item 10-31 to 10-32, but except cost of sheets. Sqm 10-33 311
Supply and fix, Plain galvanized steel sheet 20 BG, in Gutters Sqm 10-34 2721
etc. with rounded edge any pattern, (fixed length girth not
exceeding 450 mm wide) with support of galvanized , 19 mm
x 6 mm strap, spaced not exceeding one meter apart,
including angles outlet, stop ends etc.
Same as item 10-38, but size of Flat brick tiles Sqm 10-39 882
300mm × 150mm × 38mm.
Supply and fix, single layer of 300mm × 150mm × 50mm, PCC Sqm 10-40 1019
3000 psi, precast tiles on roof, jointed and pointed in CM 1:3.
Same as item 10-41, but size of flat brick tiles 300 mm x 150 Sqm 10-42 1424
mm x 38mm.
Providing and laying, one layer of 300 mm x 300 mm x 50 Sqm 10-43 1181
mm, PCC 3000 psi, Precast tiles on roof, laid on PCC 3000 psi
precast blocks 75mm x 75mm x 100mm forming space in
between, bedded, jointed and pointed in CM 1:3, and
including 300 mm x 75 mm x 100 mm PCC perforated tiles set
in CM 1:3 all round, two coats of white washing on top
complete as shown in Figure 10-2. (Coat of hot bitumen on
the surface forming bed of CC. Precast block, to be paid
separately, if ordered).
Mud Roofs
Providing and laying Mud plaster 25mm thick and leaping Sqm 10-44 278
over 50mm thick mud on roofs.
Same as item 10-44 but over 75 mm thick mud on roofs. Sqm 10-45 300
Same as item 10-44 but over 125 mm thick mud on roofs. Sqm 10-46 343
Providing and laying Mud plaster 25 mm thick including 3 mm Sqm 10-47 235
leaping on roof or floor.
Providing and laying 3 mm thick leaping on roof or floor. Sqm 10-48 102
Felt Work
Supply and fix, two ply bituminous Felt, in flashing and Sqm 10-49 477
concrete / brick work joint, joint wedged and tucked inside
end joints, stuck with approved bituminous adhesive.
Building Paper
Supply of water proofing building or insulating paper, Sqm 10-50 153
weighing 3.92 Kg per 10 sqm, and fix in any position with 50
mm side and 150 mm end laps and nailing, as described for
Felt.
Bitumen Coating
One coat of bitumen, applied hot on roof @ 0.75 Kg/sqm and Sqm 10-51 172
blinded with sand, at 0.012 cum per sqm (including cleaning
surface).
One coat of water proofing compound, using Bitumen 10/20, Sqm 10-52 150
applied hot @ 4.90 Kg /10sqm.
Same as 10-52, but @ 14.68kg /10sqm. Sqm 10-53 296
One coat of bitumen 10/20, @ 1.46 kg per sqm, blinded with Sqm 10-54 335
sand @ 0.012 cum per sqm.
Same as item 10-54, but @ 2.44 kg/sqm. Sqm 10-55 442
One coat of water proofing primer, cold sticker, (Bituminous Sqm 10-56 122
Emulsion) @ 0.75 Kg/sqm all as specified.
Water Proofing Treatments
Supply and laying, one layer of Polyester Based Roofing Sqm 10-57 653
Bitumen Felt, weighing 16 Kg to 18 Kg /10 Sqm with side lap,
end laps including water proofing bitumen primer 0.50 lit
/Sqm including bitumen sticking coat 10/20 @ 0.95 Kg/Sqm,
bitumen paint coat @ 0.95 Kg/Sqm over bitumen felt, blinded
with 3 mm aggregate @ 0.012 Cum /Sqm, complete all as
specified.
Same as item 12-6 but, laid on edge, all as specified. Sqm 12-7 1393
Providing and laying burnt bricks, laid flat, in floors, roofs and Sqm 12-8 935
channels, etc. laid, jointed and pointed in CM 1:6.
Same as item 12-8 but, laid on edge, all as specified. Sqm 12-9 1360
Providing and laying, PCC 1:3:6, as in floor, slabs, surface Cum 12-10 7013
finished smooth with neat cement and steel trowel, using
crushed or broken stone for Basement /ground floor.
Same as item 12-10 but PCC 1:2:4, all as specified. Cum 12-11 8139
Providing and laying, PCC 1:3:6 laid in floor, slabs as under Cum 12-12 6225
layer for Terrazzo / tiles top finished, using crushed or broken
stone. (for GF,1st,2nd floor and lower ground /basement 1st,
2nd, 3rd).
Same as item 12-12 but, PCC 1:2:4, all as specified. Cum 12-13 7353
Additional Labour Cost
Add to item 12-10, 12-11, 12-12 and 12-13 labour only for Cum 12-14 39
each storey above 2nd floor.
Paving Stones
Providing and laying, PCC Paving stone, 50 mm thick in Sqm 12-15 861
natural colour, as in floors, drive-way, walk-way etc., any
pattern and any shape, (Hydraulically compressed), laid and
jointed in sand, including 50mm thick sand bed as laying
course, all as specified.
Same as item 12-15 but, PCC Paving stone, 50 mm thick in Sqm 12-16 896
any colour (except natural colour), all as specified.
Providing and laying, PCC Paving stone, 60 mm thick in Sqm 12-17 912
natural colour, as in floors, streets, public parking etc., any
pattern and shape, (Hydraulically compressed), laid and
jointed in sand, including 50 mm thick sand bed as laying
course, all as specified.
Same as item 12-17 but, PCC Paving stone, 60 mm thick in in Sqm 12-18 940
any colour (except natural colour), all as specified.
Providing and laying, PCC Paving stone 80 mm thick, in Sqm 12-19 1120
natural colour, as in floors loading decks, highway petrol
pumps etc., any pattern and shape, (Hydraulically
compressed), laid and jointed in sand, including 50mm thick
sand bed as laying course, all as specified.
Same as item 12-19 but, PCC Paving stone 80 mm thick, in Sqm 12-20 1165
any colour (except natural colour), all as specified.
Same as item 12-28 but with White/ Coloured cement. Sqm 12-29 1115
Add to item12-24 to 12-29 for labuor only above 2nd floor. Sqm 12-30 120
Same as item 12-35 but Premium quality tiles of any make, Sqm 12-37 4378
size exceeding 3700 sq cm.
Providing and laying Standard quality marble tiles (Sunny Sqm 12-38 1451
grey, Badel, Ziarat grey, Sunny white, zebra, Taveera boticina,
Supreme white, Parlino stain boticina, Flower boticina), of
any size, 13 mm thick including setting, jointing , bonding
and chemical polishing, complete all as specified.
Same as item 12-44 but Deluxe quality granite tiles (Black, Sqm 12-45 6634
Cobra, Rao silk, Sea green, Chagi pink, Paradizo), all as
specified.
Same as item 12-44 but Premium quality granite tiles (Chilly Sqm 12-46 9927
red, Coffe brown, Gibrana, Baltic brown, Red Rubi, Cherry
pink, Cherry brown), all as specified.
Mosaic Tiles
Providing and laying, Mosaic tiles, 300 mm x 300 mm x 25 Sqm 12-47 1713
mm of white cement, on walls and floors laid, set in CM (1:2)
and joints grouted with white / coloured cement, chemical
polished, complete.
Same as item 12-47 but in ordinary cement. Sqm 12-48 1555
Same as item 12-35 to 12-48 but fixing only. Sqm 12-49 670
Add to item 12-47 to 12-48 for labour only for each storey Sqm 12-50 120
above 2nd floor.
Providing and laying of dry bond, all as specified. Sqm 12-51 132
Pointing
Racking out joints of old floors, roofs etc. with brick laid on Sqm 12-52 141
edges, built in any mortar, including preparing surface for re-
pointing.
Same as item 12-52 but with bricks or tiles laid flat. Sqm 12-53 107
Pointing Flush in CM 1:3, to old or new brick floors laid on Sqm 12-54 305
edge.
Same as item 12-54, but bricks laid flat. Sqm 12-55 197
Three applications of Sodium Silicate on concrete surface. Sqm 12-56 103
Floor Toping
Providing and laying, Floor Toping 50 mm thick with PCC Sqm 12-57 747
3000psi compressive cylindrical strength all as specified (Steel
reinforcement to be paid under Section-9).
Providing and laying, Bond Breaking materials, using 0.102 Sqm 12-58 372
mm thick Polythene film, over normal thickness of concrete
floor.
Providing and laying, Screed bed 50 mm thick on bond Sqm 12-59 1235
breaking material as specified.
PVC Floor Tiles
Supply and fix, PVC Floor Plain / Textured Tiles, 2 mm thick. Sqm 12-60 1449
Same as item 14-5, but except cost of Soft board sheet. Sqm 14-6 382
Same as item 14-23, but 2 mm thick, Fibre Glass sheet. Sqm 14-24 2143
Same as item 14-23, but 3 mm thick, Fibre Glass sheet. Sqm 14-25 2906
Plaster of Paris (POP) Ceiling
Supply and fix, POP Tiles (600 mm x 600 mm x 20 mm), fixed Sqm 14-26 1211
in ceiling in any design, partitions and dados etc.
Add to item 14-26, if fixed in repairs. Sqm 14-27 291
Supply and fix, POP border, in any shape and design, girth not Metre 14-28 159
exceeding 150 mm, complete.
Same as item 14-28, but girth exceeding 150 mm but not Metre 14-29 221
exceeding 300 mm, complete.
Add to item 14-28 and 14-29, if fixed in repairs. Metre 14-30 30
Gypsum Ceiling
Supply and fix Gypsum sheet 1200 mm x 2400 mm x 12.5 Sqm 14-31 2027
mm thick, including Aluminium Tee and Aluminium angle, 25
mm x 25 mm x 1 mm, including hanger clips, jointing clips
and 14 SWG, GI wire etc., complete.
Same as item 14-31 but, Gypsum Ceiling 600 mm x 600 mm x Sqm 14-32 1571
7.5 mm thick, all as specified.
Add to item 14-31 and 14-32, if fixed in repairs. Sqm 14-33 291
Replacement of Gypsum Tiles only, 1200 mm x 2400 mm x Sqm 14-34 814
12.5 mm thick or 600 mm x 600 mm x 7.5 mm thick.
1st Coat of painting on new or old work such as timber work Sqm 15-12 97
ceiling and timber boarding etc. of any description with
synthetic enamel paint.
Same as item 15-12, but second and subsequent coat. Sqm 15-13 82
Prime coat on new work such as glazed or gauzed window Sqm 15-14 137
and fanlight, as specified.
1st Coat of painting on new or old work such as glazed or Sqm 15-15 114
gauzed window and fanlight, with Synthetic Enamel paint.
Same as item 15-15, but second and subsequent coat. Sqm 15-16 103
Primer Coat on new work such as doors of any type and Sqm 15-17 153
description as specified.
1st Coat of painting to new or old work such as doors of any Sqm 15-18 110
type and description with synthetic enamel paint.
Same as item 15-18, but 2nd and subsequent coat. Sqm 15-19 95
Primer coat on new work such as fillets, framings, skirting and Metre 15-20 13
similar work not exceeding 150 mm in girth as specified.
1st coat of painting on new or old work such as fillets, Metre 15-21 7
framings, skirting and similar work not exceeding 150 mm
girth with Synthetic Enamel Paint.
Same as item 15-21, but second and subsequent coat. Metre 15-22 5
Primer coat on new work such as detached articles not C.No 15-23 682
exceeding 900 Sqcm, as specified.
1st coat of painting on new or old work such as detached C.No 15-24 492
articles not exceeding 900 Sqcm with Synthetic Enamel Paint.
Same as item 15-24, but 2nd and subsequent coat. C.No 15-25 354
Painting Steel and Iron Work
1st Coat of painting on new or old work such as steel doors, Sqm 15-26 87
windows and CSWs of any type and description with
Synthetic Enamel paint.
Same as item 15-26, but 2nd and subsequent coat. Sqm 15-27 61
1st Coat of painting on new or old work such as iron guard Sqm 15-28 67
bars, iron bars gates, railing and similar open work with
Synthetic Enamel paint.
Same as item 15-28, but 2nd and subsequent coat. Sqm 15-29 46
1st Coat of painting on new or old work such as plain and Sqm 15-30 95
corrugated sheets in roofs, partitions etc. with Synthetic
Enamel paint. (measured flat not girthed).
Same as item 15-30, but 2nd and subsequent coat. Sqm 15-31 65
1st Coat of painting on new or old work such as pipes, gutters Metre 15-32 14
and similar work not exceeding 150mm in girth with
Synthetic Enamel paint.
Same as item 15-32, but 2nd and subsequent coat. Metre 15-33 10
1st Coat of painting on new or old work such as detached C.No 15-34 855
articles not exceeding 900 Sqcm with Synthetic Enamel paint.
Same as item 15-34, but 2nd and subsequent coat. C.No 15-35 586
1st Coat of painting on new or old surfaces of any description Sqm 15-36 95
of steel with Red Oxide paint.
Same as item 15-36, but 2nd and subsequent coat. Sqm 15-37 83
1st Coat of painting on new or old work such as iron guard Sqm 15-38 70
bars, iron bar gates, gratings, railings and similar open work,
with Red Oxide paint.
Same as item 15-38, but 2nd and subsequent coat. Sqm 15-39 65
1st Coat of painting on new or old work such as pipes, gutters Metre 15-40 14
and similar work not exceeding 150 mm in girth with Red
Oxide paint.
Same as item 15-40, but 2nd and subsequent coat. Metre 15-41 12
1st Coat of painting of new or old work such as detached C.No 15-42 855
articles not exceeding 900 Sq cm with Red Oxide paint.
Same as item 15-42, but 2nd and subsequent coat. C.No 15-43 750
Aluminium Painting
1st Coat of painting on new or old work such as steel doors Sqm 15-44 95
and window with Aluminium paint.
Same as item 15-44, but 2nd and subsequent coat. Sqm 15-45 67
1st Coat of painting on new or old such as corrugated sheets Sqm 15-46 87
in roofs, partitions, etc., (measured flat and not girthed) with
Aluminium paint.
Same as item 15-46, but 2nd and subsequent coat. Sqm 15-47 71
1st Coat of painting on new or old work such as pipes, Metre 15-48 14
gutters, and similar work not exceeding 150 mm internal dia
with Aluminium paint.
Same as item 15-48, but 2nd and subsequent coat. Metre 15-49 10
1st Coat of painting on new or old work such as detached C.No 15-50 851
articles not exceeding 900 Sq cm with Aluminium paint.
Same as item 15-50, but 2nd and subsequent coat. C.No 15-51 598
Painting on Plastered Walls
Surface preparation (for dampness) by provision of a film Sqm 15-52 101
with Alkali Resisting primer on plastered wall or ceiling.
1st Coat of painting on new or old work such as walls Sqm 15-53 81
including all detached attachment with Plastic Emulsion paint.
Same as item 15-53, but 2nd and subsequent coat. Sqm 15-54 57
1st Coat of painting on new or old pipes, picture rails, dados Metre 15-55 14
etc. 150mm in girth with Plastic emulsion paint.
Same as item 15-55, but 2nd and subsequent coat. Metre 15-56 10
1st Coat of Weather Resistant paint on exterior wall for old Sqm 15-57 158
surface.
1st Coat of Weather Resistant paint on exterior wall on new Sqm 15-58 125
surface.
Same as item 15-57 and 15-58, but 2nd and subsequent coat. Sqm 15-59 93
1st coat of texture paint on any surface complete all as Sqm 15-60 61
specified.
Same as item 15-60 but 2nd and subsequent coat. Sqm 15-61 58
Add to item 15-57 to 15-61; additional labour for 2nd and Sqm 15-62 39
each subsequent storey for painting of exterior surfaces only.
Abrasive / Sand Blasting of Fuel Tank for new un-painted (un- Sqm 15-103 779
corroded) steel surface all as specified.
Same as item 15-103 but corroded un-painted steel surface. Sqm 15-104 1147
Same as item 15-103 but previously painted (old work) steel Sqm 15-105 1044
surface.
Primer coat imported (USA or Europe) to steel surface buff or Sqm 15-106 4028
ivory colour, minimum 125 micron dry film thickness,
complete as specified.
Finish coat imported (USA or Europe) to steel surface white Sqm 15-107 1147
colour, minimum 125 micron film thickness complete as
specified.
Supply and fix, Double Glazing glass 5 mm thick tinted, fixed Sqm 16-17 2436
to timber or steel sashes with hard/ soft wood beads and
screws or by use of rubber lining.
Supply and fix, Re-inforced glass sheet 5 mm thick, fixed to Sqm 16-18 3839
timber/ steel sashes with hard/ soft wood beeds and screws
etc.
Supply and fix Frosted paper of any design/ pattern over plain Sqm 16-19 1595
glass complete, all as specified.
Hacking Out
Hacking out old broken glass from sashes, remove any Sqm 16-20 473
serviceable portions to store and dispose of rubbish.
Tempering
Tempering to any thickness of glass sheet, all as specified. Sqm 16-21 1949
Glass Blocks
Supply and fix, Glass blocks, size 190 mm x 190 mm x 80 mm, Each 16-22 665
as specified.
Same as item 16-22, but fixing only. Each 16-23 102
Add to item 16-22 and 16-23, if fixed in repairs. Each 16-24 60
Same as item 18-40 but 6.40 mm thickness, supply and fixing. Metre 18-41 8862
Same as item 18-40 or 18-41, but fixing only. Metre 18-42 302
Add to item 18-40, 18-41 or 18-42 if removal only. Metre 18-43 181
Same as item 18-40 but 250 mm dia. (thickness 4.8mm) Metre 18-44 7855
Same as item 18-133, 18-142, 18-152 or 18-162 but fixing Each 18-172 13
only.
Same as item, 18-134, 18-143, 18-153 or 18-163 but fixing Each 18-173 14
only.
Same as item 18-135, 18-144, 18-154 or 18-164 but fixing Each 18-174 9
only.
Same as item 18-136, 18-145, 18-155, or18-165 but fixing Each 18-175 18
only.
Same as item 18-137, 18-146, 18-156 or 18-166 but fixing Each 18-176 23
only.
Same as item, 18-138, 18-147, 18-157, or 18-167 but fixing Each 18-177 24
only.
Same as item 18-139, 18-148, 18-158 or 18-168 but fixing Each 18-178 35
only.
Same as item 18-140, 18-149, 18-159 or 18-169 but fixing Each 18-179 35
only.
Same as item 18-141, 18-150, 18-160 or 18-170 but fixing Each 18-180 42
only.
Add to item 18-132, 18-151,18-161or 18-171 if removal only. Each 18-181 4
Nipple-GI
Nipple, 15 mm dia, supply and fixing Each 18-240 58
Same as item 18-240, but 20 mm dia Each 18-241 91
Same as item 18-240, but 25 mm dia Each 18-242 110
Same as item 18-240, but 32 mm dia Each 18-243 141
Same as item 18-240, but 40 mm dia Each 18-244 197
Same as item 18-240, but 50 mm dia Each 18-245 304
Same as item 18-240, but 65 mm dia Each 18-246 456
Same as item 18-240, but 80 mm dia Each 18-247 838
Same as item 18-240, but 100 mm dia Each 18-248 1240
Same as item 18-240 but 150 mm dia Each 18-249 4186
Same as item 18-240, but fixing only. Each 18-250 12
Same as item 18-241 but fixing only. Each 18-251 12
Same as item 18-242 but fixing only. Each 18-252 14
Same as item 18-243, but fixing only. Each 18-253 17
Same as item 18-244, but fixing only. Each 18-254 18
Same as item 18-245, but fixing only. Each 18-255 23
Same as item 18-246, but fixing only. Each 18-256 24
Same as item 18-247, but fixing only. Each 18-257 32
Same as item 18-248, but fixing only. Each 18-258 36
Same as item 18-249, but fixing only. Each 18-259 42
Add to item 18-240 or 18-250 if removal only. Each 18-260 6
Add to item 18-241 or 18-251 if removal only. Each 18-261 7
Add to item 18-242 or 18-252 if removal only. Each 18-262 8
Add to item 18-243 or 18-253 if removal only. Each 18-263 9
Add to item 18-244 or 18-254 if removal only. Each 18-264 14
Add to item 18-245 or 18-255 if removal only. Each 18-265 14
Add to item 18-246 or 18-256 if removal only. Each 18-266 14
Add to item 18-247 or 18-257 if removal only. Each 18-267 17
Add to item 18-248 or 18-258 if removal only. Each 18-268 18
Add to item 18-249 or 18-259 if removal only. Each 18-269 24
Check Nut – GI
Check nut GI, 15 mm dia, supply and fixing. Each 18-270 29
Same as item 18-270 but 20 mm dia. Each 18-271 38
Same as item 18-270 but 25 mm dia. Each 18-272 44
Same as item 18-270 but 32 mm dia. Each 18-273 40
Same as item 18-270 but 40 mm dia. Each 18-274 62
Same as item 18-270 but 50 mm dia. Each 18-275 84
Same as item 18-270 but 65 mm dia. Each 18-276 144
Same as item 18-270 but 80 mm dia. Each 18-277 196
Same as item 18-270 but 100 mm dia. Each 18-278 361
Same as item 18-270 but 150 mm dia. Each 18-279 740
Plugs – GI / MS
GI/MS plug screwed BSS, 15 mm dia, supply and fixing. Each 18-280 17
Same as item 18-280 but 20 mm dia. Each 18-281 26
Same as item 18-280 but 25 mm dia. Each 18-282 28
Same as item 18-280 but 32 mm dia. Each 18-283 79
Same as item 18-280 but 40 mm dia. Each 18-284 56
Same as item 18-280 but 50 mm dia. Each 18-285 75
Same as item 18-280 but 65 mm dia. Each 18-286 157
Same as item 18-280 but 80 mm dia. Each 18-287 184
Same as item 18-280 but 100 mm dia. Each 18-288 331
Same as item 18-270 or 18-280 but fixing only. Each 18-289 6
Same as item 18-271 or 18-281 but fixing only. Each 18-290 8
Same as item 18-272 or 18-282 but fixing only. Each 18-291 8
Same as item 18-273 or 18-283, but fixing only. Each 18-292 4
Same as item 18-274 or 18-284 but fixing only. Each 18-293 11
Same as item 18-275 or 18-285 but fixing only Each 18-294 12
Same as item 18-276 or 18-286 but fixing only. Each 18-295 12
Same as item 18-277 or 18-287 but fixing only. Each 18-296 16
Same as item 18-278 or 18-288 but fixing only. Each 18-297 19
Same as item 18-279 but fixing only. Each 18-298 16
Add to item 18-270, 18-280 or 18-289 if removal only. Each 18-299 2
Add to item 18-271, 18-281 or 18-290 if removal only. Each 18-300 4
Add to item 18-272, 18-282 or 18-291 if removal only. Each 18-301 3
Add to item 18-273, 18-283 or 18-292 if removal only. Each 18-302 3
Add to item 18-274 18-284 or 18-293 if removal only. Each 18-303 4
Add to item 18-275, 18-285 or 18-294 if removal only. Each 18-304 5
Add to item 18-276, 18-286 or 18-295 if removal only. Each 18-305 5
Add to item 18-277, 18-287 or 18-296 if removal only. Each 18-306 6
Add to item 18-278, 18-288 or 18-297 if removal only. Each 18-307 8
Add to item 18-279 or 18-298 if removal only. Each 18-308 9
Canvas pipe of 40 mm dia, supply and fixing. Metre 18-309 323
Same as item 18-309, but 50 mm dia. Metre 18-310 361
Same as item 18-309, but 65 mm dia. Metre 18-311 421
Same as item 18-309, but 75 / 80mm dia. Metre 18-312 461
Same as item 18-309 to 18-312 but fixing only. Metre 18-313 86
Add to item 18-309 to 18-312 or 18-313, if removal only. Metre 18-314 65
CP Mixer, 15mm dia, fancy head, any pattern and shape, Each 18-328 2425
screw down, high pressure, lettered Hot and cold with long
screw channels and fly nuts complete, supply and fixing.
Stop Cock
Stop cock brass, CP, screw down, high pressure, fancy type, Each 18-331 743
15mm dia, supply and fixing.
Same as item 18- 331 but concealed type. Each 18-332 966
Same as item 18-331, but tee stop cock. Each 18-333 743
Same as item 18-331 to 18-333, but fixing only. Each 18-334 41
Add to item 18-331 to 18-333 or 18-334, if removal only. Each 18-335 26
Valves
Valves, "Peet" pattern, strong gunmetal, high pressure, "Full- Each 18-345 551
way" with iron wheel head, screwed both ends for iron pipe,
15 mm dia, supply and fixing.
Same as item 18-345, but 20 mm dia. Each 18-346 816
Same as item 18-345, but 25 mm dia. Each 18-347 1231
Same as item 18-345, but 40 mm dia. Each 18-348 2111
Same as item 18-345, but 50 mm dia. Each 18-349 3805
Same as item 18-345, but 65 mm dia. Each 18-350 4647
Globe valves, gunmetal, screwed both ends, complete with Each 18-351 1205
steel handle Class-150, 15 mm dia, supply and fixing.
Same as item 18-347, 18-353, or 18-374, but fixing only. Each 18-384 55
Same as item 18-348, 18-354, or18-375, but fixing only. Each 18-385 71
Same as item 18-349, 18-355, or 18-376, but fixing only. Each 18-386 85
Same as item 18-350, 18-356 or 18-377 but fixing only. Each 18-387 87
Same as item 18-357, 18-360, 18-366, or 18-378 but fixing Each 18-388 357
only.
Same as item 18-358, 18-361, 18-367or 18-379 but fixing Each 18-389 421
only.
Same as item 18-359, 18-362, 18-368 or 18-380, but fixing Each 18-390 656
only.
Same as item 18-363, 18-369, or 18-381, but fixing only. Each 18-391 785
Same as item 18-364 or 18-370, but fixing only. Each 18-392 885
Same as item 18-365 or, 18-371, but fixing only. Each 18-393 1432
Add to item 18-345, 18-351, 18-372 or 18-382, if removal Each 18-394 26
only.
Add to item 18-346, 18-352, 18-373, or 18-383 if removal Each 18-395 31
only.
Add to item 18-347, 18-353, 18-374, or 18-384 if removal Each 18-396 36
only.
Add to item 18-348, 18-354, 18-375, or 18-385, if removal Each 18-397 47
only.
Add to item 18-349, 18-355, 18-376, or 18-386 if removal Each 18-398 57
only.
Add to item 18-350, 18-356, 18-377, or 18-387 if removal Each 18-399 57
only.
Add to item 18-357, 18-360, 18-366, 18-378 or 18-388, if Each 18-400 129
removal only.
Add to item 18-358, 18-361, 18-367, 18-379 or 18-389, if Each 18-401 195
removal only.
Add to item 18-359, 18-362, 18-368, 18-380 or 18-390, if Each 18-402 307
removal only.
Add to item 18-363, 18-369, 18-381 or 18-391, if removal Each 18-403 369
only.
Add to item 18-364 or 18-370 or 18-392, if removal only. Each 18-404 395
Add to item 18-365, 18-371 or 18-393, if removal only Each 18-405 661
Fire Hydrant
Fire Hydrant flanged and drilled to BS Table 18-1-10, Each 18-439 19670
complete with rubber packing, 65 mm dia, supply and fixing.
Flange – MS / GI Screwed
Flanges MS/GI, drilled to B.S Table 18-1-10, for screwed pipe, Each 18-443 443
25 mm dia, supply and fixing.
Same as item 18-443, but 40mm dia. Each 18-444 515
Same as item 18-443, but 50mm dia. Each 18-445 522
Same as item 18-443, but 65mm dia. Each 18-446 709
Same as item 18-443, but 80mm dia. Each 18-447 797
Same as item 18-443, but 100mm dia. Each 18-448 1470
Same as item 18-443, but 150mm dia. Each 18-449 2113
Same as item 18-443, but 200mm dia. Each 18-450 4110
Same as item 18-443, but 250mm dia. Each 18-451 5887
Same as item 18-443, but 300mm dia. Each 18-452 7307
Same as item 18-443, but fixing only. Each 18-453 83
Same as item 18-444, but fixing only. Each 18-454 95
Same as item 18-445, but fixing only. Each 18-455 102
Same as item 18-446, but fixing only. Each 18-456 166
Same as item 18-447, but fixing only. Each 18-457 197
Same as item 18-448, but fixing only. Each 18-458 211
Same as item 18-449, but fixing only. Each 18-459 313
Same as item 18-450, but fixing only. Each 18-460 429
Same as item 18-451, but fixing only. Each 18-461 487
Same as item 18-452, but fixing only. Each 18-462 689
Add to item 18-443 or 18-453, if removal only. Each 18-463 18
Add to item 18-444 or 18-454, if removal only. Each 18-464 23
Add to item 18-445 or 18-455, if removal only. Each 18-465 28
Add to item 18-446 or 18-456, if removal only. Each 18-466 52
Add to item 18-447 or 18-457, if removal only. Each 18-467 65
Add to item 18-448 or 18-458, if removal only. Each 18-468 98
Add to item 18-449 or 18-459 if removal only. Each 18-469 122
Add to item 18-450 or 18-460, if removal only. Each 18-470 184
Add to item 18-451 or 18-461, if removal only. Each 18-471 197
Add to item 18-452 or 18-462, if removal only. Each 18-472 276
Flange – MS / GI Welded
Flanges MS/GI, drilled to B.S, Table 18-1-10, for Welded pipe, Each 18-473 388
25mm dia, supply and fixing.
Same as item 18-473, but 40mm dia. Each 18-474 585
Same as item 18-473, but 50mm dia. Each 18-475 683
Same as item 18-473, but 65mm dia. Each 18-476 791
Same as item 18-473, but 80mm dia. Each 18-477 902
Same as item 18-473, but 100mm dia. Each 18-478 1397
Same as item 18-473, but 150mm dia. Each 18-479 2142
Same as item 18-473, but 200mm dia. Each 18-480 3089
Same as item 18-473, but 250mm dia. Each 18-481 4335
Same as item 18-473, but 300mm dia. Each 18-482 5702
Same as item 18-473, but fixing only. Each 18-483 150
Same as item 18-474, but fixing only. Each 18-484 225
Same as item 18-475, but fixing only. Each 18-485 299
Same as item 18-476, but fixing only. Each 18-486 370
Same as item 18-477, but fixing only. Each 18-487 445
Same as item 18-478, but fixing only. Each 18-488 592
Same as item 18-479, but fixing only. Each 18-489 881
Same as item 18-480, but fixing only. Each 18-490 1168
Same as item 18-481, but fixing only. Each 18-491 1455
Same as item 18-482, but fixing only. Each 18-492 1743
Add to item 18-473 or 18-483, if removal only. Each 18-493 6
Add to item 18-474 or 18-484, if removal only. Each 18-494 10
Add to item 18-475 or 18-485, if removal only. Each 18-495 14
Add to item 18-476 or 18-486, if removal only. Each 18-496 13
Add to item 18-477 or 18-487, if removal only. Each 18-497 17
Add to item 18-478 or 18-488, if removal only. Each 18-498 20
Add to item 18-479 or 18-489 if removal only. Each 18-499 23
Add to item 18-480 or 18-490, if removal only. Each 18-500 23
Add to item 18-481 or 18-491, if removal only. Each 18-501 23
Add to item 18-482 or 18-492, if removal only. Each 18-502 23
Brass Spindles
Brass Spindle with nuts, for 80 mm dia, Gate valves, supply Each 18-503 2246
and fixing.
Same as item 18-503, but 100 mm dia. Each 18-504 3086
Same as item 18-503, but 150 mm dia. Each 18-505 4646
Same as item 18-503, but 200 mm dia. Each 18-506 5573
Same as item 18-503, but 250 mm dia. Each 18-507 6533
Same as item 18-503, but 300 mm dia. Each 18-508 11573
Same to item 18-503 to 18-505, but fixing only. Each 18-509 86
Same as item 18-506 to 18-508, but fixing only. Each 18-510 173
Add to item 18-503 to 18-505 or 18-509 if removal only. Each 18-511 65
Add to item 18-506 to 18-508 or 18-510 if removal only. Each 18-512 129
Add to item 18-533 to 18-534 or 18-537, if removal only. Each 18-540 388
Same as item 18-643, but 180 x 110mm, 180 x 125 mm or Each 18-647 3163
180 x 160 mm dia.
Same as item 18-643, but 200 x 160 mm or 200 x 180 mm Each 18-648 3843
dia.
Same as item 18-643 but 200 x 90 mm dia, Each 18-649 3843
Same as item 18-643, but 200 x 110 mm dia. Each 18-650 4188
Same as item 18-643, but 200 x 160 mm dia. Each 18-651 4188
Same as item 18-643 but 250 x 90 mm dia, Each 18-652 8416
Same as item 18-643 but 250 x 110 mm dia, Each 18-653 8416
Same as item 18-643 but 250 x 160 mm dia, Each 18-654 7577
Same as item 18-643, but 250 x 180 mm dia. Each 18-655 7914
Same as item 18-643 but 250 x 200 mm dia, Each 18-656 7927
Same as item 18-643 but 280 x 110 mm dia, Each 18-657 10175
Same as item 18-643 but 280 x 160 mm dia, Each 18-658 10175
Same as item 18-643 but 280 x 200 mm dia, Each 18-659 11523
Same as item 18-643 but 315 x 90 mm dia, Each 18-660 12050
Same as item 18-643 but 315 x 110 mm dia, Each 18-661 12188
Same as item 18-643 but 315 x 160 mm dia, Each 18-662 12435
Same as item 18-643 but 315 x 250 mm dia, Each 18-663 12615
Same as item 18-643 but 355 x 160 mm dia, Each 18-664 13147
Same as item 18-643 but 400 x 315 mm dia. Each 18-665 15914
Same as item 18-643 but 450 x 200 mm dia, Each 18-666 28591
Same as item 18-618 to 18-620, 18-627 to 18-629, but fixing Each 18-667 35
only.
Same as item 18-621 to 18-623, 18-630 to 18-635 but fixing Each 18-668 69
only.
Same as item 18-624 to 18-626, 18-636 to 18-640, but fixing Each 18-669 86
only.
Same as item 18-641 to 18-646, but fixing only. Each 18-670 121
Same as item 18-647 to 18-651 but fixing only. Each 18-671 342
Same as item 18-652 to 18-663, but fixing only. Each 18-672 342
Same as item 18-664 to 18-666, but fixing only. Each 18-673 442
Add to item 18-618 to 18-620, 18-627 to 18-629 or 18-667 if Each 18-674 26
removal only.
Add to item 18-621 to 18-623, 18-630 to 18-635 or 18-668 if Each 18-675 52
removal only.
Add to item 18-624 to 18-626, 18-636 to 18-640 or 18-669, if Each 18-676 65
removal only.
Add to item 18-641 to 18-646 or 18-670, if removal only. Each 18-677 91
Add to item 18-647 to 18-651 or 18-671, if removal only. Each 18-678 138
Add to item 18-652 to 18-663 or 18-672, if removal only. Each 18-679 173
Add to item 18-664 to 18-666 or 18-673, if removal only. Each 18-680 206
Tee Equal
Tee Equal, 20 mm dia, for PE pipe, supply and fixing. Each 18-681 175
Same as item 18-681, but 25 mm dia. Each 18-682 271
Same as item 18-681, but 32 mm dia. Each 18-683 354
Same as item 18-681, but 40 mm dia. Each 18-684 624
Same as item 18-681, but 50 mm dia. Each 18-685 686
Same as item 18-681, but 63 mm dia. Each 18-686 830
Same as item 18-681, but 75 mm dia. Each 18-687 960
Same as item 18-681, but 90 mm dia. Each 18-688 1256
Same as item 18-681, but 110 mm dia, with Butt Fusion Each 18-689 1599
fitting.
Same as item 18-689, but 125 mm dia. Each 18-690 2886
Same as item 18-689, but 160 mm dia. Each 18-691 3504
Same as item 18-689, but 180 mm dia. Each 18-692 6439
Same as item 18-689, but 200 mm dia Each 18-693 6518
Same as item 18-689, but 250 mm dia. Each 18-694 14292
Same as item 18-689, but 280 mm dia. Each 18-695 27023
Same as Item 18-689, but 315 mm dia. Each 18-696 28525
Same as Item 18-689, but 355 mm dia. Each 18-697 34432
Same as Item 18-689, but 400 mm dia. Each 18-698 48709
Same as Item 18-689, but 450 mm dia. Each 18-699 79646
Reducing Tee
Reducing Tee 25 x 20 mm dia for PE pipe, supply and fixing. Each 18-700 297
Bend
Bend 20 mm dia for PE pipe, supply and fixing. Each 18-765 121
Same as item 18-765, but 25 mm dia. Each 18-766 171
Same as item 18-765, but 32 mm dia. Each 18-767 225
Same as item 18-765, but 40 mm dia. Each 18-768 430
Same as item 18-765, but 50 mm dia. Each 18-769 663
Same as item 18-765, but 63 mm dia. Each 18-770 1047
Same as item 18-765, but 75 mm dia. Each 18-771 1641
Same as item 18-765, but 90 mm dia. Each 18-772 1982
Elbow
Elbow, 110 mm dia, for PE pipe, with Butt Fusion joint, supply Each 18-773 1196
and fixing.
Same as item 18-773, but 125 mm dia. Each 18-774 2588
Same as item 18-773, but 160 mm dia. Each 18-775 2738
Same as item 18-773, but 180 mm dia. Each 18-776 4483
Same as item 18-773, but 200 mm dia. Each 18-777 5038
Same as item 18-773, but 250 mm dia. Each 18-778 8449
Same as item 18-773, but 280 mm dia Each 18-779 18673
Same as Item18-773, but 315 mm dia Each 18-780 20267
Same as Item18-773, but 355 mm dia Each 18-781 26501
Same as Item18-773, but 400 mm dia Each 18-782 34432
Same as Item18-773, but 450 mm dia Each 18-783 47124
Male / Female Bend
Male / Female Bend, 20 x 15 mm dia, for PE pipe, supply and Each 18-784 93
fixing
Same as item 18-784, but 20 x 20 mm dia Each 18-785 133
Same as item 18-784, but 25 x 25 mm dia Each 18-786 129
Same as item 18-784, but 25 x 20 mm dia Each 18-787 196
Same as item 18-784, but 25 x 15 mm dia Each 18-788 129
Same as item 18-784, but 32 x 20 mm dia Each 18-789 193
Same as item 18-784, but 32 x 25 mm dia Each 18-790 249
Same as item 18-784, but 40 x 32 mm dia Each 18-791 434
Same as item 18-784, but 50 x 32 mm dia Each 18-792 499
Same as item 18-784, but 50 x 40 mm dia Each 18-793 536
Same as item 18-784, but 63 x 50 mm dia Each 18-794 722
Same as item 18-784, but 90 x 75 mm dia Each 18-795 2069
Same as item 18-765 to 18-767, 18-784 to 18-787, but fixing Each 18-796 35
only.
Same as item 18-768 to 18-770, 18-788 to 18-791, but fixing Each 18-797 69
only.
Same as item 18-771 to 18-772, 18-792 to 18-795, but fixing Each 18-798 86
only.
Same as item 18-773 to 18-775, but fixing only. Each 18-799 121
Same as item 18-776 to 18-777, but fixing only. Each 18-800 121
Same as item 18-778 to 18-780, but fixing only. Each 18-801 121
Same as item 18-781 to 18-783, but fixing only. Each 18-802 690
Add to item 18-765 to 18-767, 18-784 to 18-787 or 18-796 if Each 18-803 26
removal only.
Add to item 18-768 to 18-770, 18-788 to 18-791, or 18-797 if Each 18-804 52
removal only.
Add to item 18-771 to 18-772, 18-792 to 18-795, or 18-798 if Each 18-805 65
removal only.
Add to item 18-773 to 18-775, or 18-799 if removal only. Each 18-806 91
Add to item 18-781 to 18-783, or 18-802 if removal only. Each 18-809 518
Add to item 18-856 to 18-858, or 18-865, if removal only. Each 18-870 129
Add to item 18-859 to 18-861, or 18-866, if removal only. Each 18-871 155
End Cap
End Cap 20 mm dia, for PE pipe, supply and fixing. Each 18-872 92
Same as item 18-872, but 25 mm dia. Each 18-873 113
Same as item 18-872, but 32 mm dia. Each 18-874 139
Same as item 18-872, but 40 mm dia. Each 18-875 229
Same as item 18-872, but 50 mm dia. Each 18-876 370
Same as item 18-872, but 63 mm dia. Each 18-877 473
Same as item 18-872, but 75 mm dia. Each 18-878 494
Same as item 18-872, but 90 mm dia. Each 18-879 524
Same as item 18-872, but 110 mm dia. Each 18-880 545
Same as item 18-872, but 125 mm dia Butt Fusion fitting. Each 18-881 1038
Add to item 18-899 to 18-901 or 18-904, if removal only. Metre 18-907 129
Coupler / Socket
PPR Coupler / Socket, 20 mm dia, supply and fixing. Each 18-908 55
Same as item 18-908, but 25 mm dia. Each 18-909 54
Same as item 18-908, but 32 mm dia. Each 18-910 68
Same as item 18-908, but 40 mm dia. Each 18-911 127
Same as item 18-908, but 50 mm dia. Each 18-912 185
Same as item 18-908, but 63 mm dia. Each 18-913 280
Same as item 18-908, but 75 mm dia. Each 18-914 553
Same as item 18-908, but 90 mm dia. Each 18-915 957
Same as item 18-908, but 110 mm dia Each 18-916 1417
Reducing Coupler / Socket
PPR Reducing Coupler / Socket 25 x 20 mm dia, supply and Each 18-917 65
fixing.
Same as item 18-917, but 32 x 20 mm dia. Each 18-918 73
Same as item 18-917, but 32 x 25 mm dia. Each 18-919 80
Same as item 18-917, but 40 x 20 mm, 40 x 25 mm or 40 x 32 Each 18-920 153
mm dia.
Same as item 18-917, but 50 x 25 mm, 50 x 32 mm or 50 x 40 Each 18-921 154
mm dia.
Same as item 18-917, but 63 x 25 mm dia. Each 18-922 202
Same as item 18-917, but 63 x 35 mm, 63 x 40 mm or 63 x 50 Each 18-923 312
mm dia.
Same as item 18-917, but 75 x 63 mm dia. Each 18-924 1622
Same as item 18-917, but 90 x 63 mm or 90 x 75mm dia. Each 18-925 1622
Steel Sch 40 Gate, valve flanged and drilled to B.S Table 18-1- Each 18-1059 10467
10, Rising Steam, complete with packing sheet 40mm dia,
supply and fixing.
Same as item 18-1059 but 50mm dia. Each 18-1060 12467
Same as item 18-1059 but 80mm dia. Each 18-1061 18611
Same as item 18-1059 but 100mm dia. Each 18-1062 24113
Same as item 18-1059 but 150mm dia. Each 18-1063 41113
Same as item 18-1059 to 18-1063 but fixing only. Each 18-1064 288
Add to item 18-1059 to 18-1063 or 18-1064, if removal only. Each 18-1065 144
Same as item 19-1, but 2 HP motor, for 25/30 M head. Each 19-2 41630
Centrifugal Pumping set, AC, electric motor driven, 220 /230 Each 19-3 36541
V, SP, 1 HP, 50 cycles, mounted on a common channel base,
total head 20/25 Motor efficiency IE-2, insulation class ’F’,
enclosure characteristics IP-55, supply and fixing.
Same as item 19-3, but with 1/2 HP motor for 10/15 M head. Each 19-4 31790
Same as item 19-47, but 300 mm dia and 6.35 mm thick. Metre 19-49 12965
Supply and Lowering in Predrilled bore hole 200 mm dia V- Metre 19-50 30605
WIRE V-WEDGE continuous slot, stainless steel, water well
screen proper welded with MS pipe complete in all respect.
Same as item 19-59, but for 300 mm dia blind pipe/strainer. Metre 19-61 476
Same as item 19-68, but pump capacity above 1.0 and upto Each 19-74 2783686
1.5 cusec, 63-92 M head, pump setting upto 46 M with
motor 60 HP.
Same as item 19-68, but pump capacity above 1.5 and upto Each 19-75 2667588
2.0 cusec, 40-62 M head, pump setting upto 46 M, with
motor 50 HP
Same as item 19-68, but pump capacity above 1.0 and upto Each 19-76 2541648
1.5 cusec, 47-70 M head, pump setting upto 46 M with
motor 40 HP.
Same as item 19-68, but pump capacity above 0.80 and upto Each 19-77 2289918
1.0 cusec, 68-85 M head, pump setting upto 46 M with
motor 30 HP.
Same as item 19-68, but pump capacity above 2.0 and upto Each 19-78 2676628
2.25 cusec, 40-50 M head, pump setting upto 46 M with
motor 60 HP.
Same as item 19-68, but pump capacity above 2.0 and upto Each 19-79 3019008
2.25 cusec, 58-78 M head, pump setting up to 46 M with
motor 100 HP.
Same as item 19-68, but pump capacity above 0.75 and upto Each 19-80 2315565
1.0 cusec, 66-88 M head, pump setting upto 46 M with
motor 40 HP.
Same as item 19-68, but fixing only. Each 19-81 3945
Same as item 19-69, but fixing only. Each 19-82 4875
Same as item 19-70, but fixing only. Each 19-83 4875
Same as item 19-71, but fixing only. Each 19-84 5805
Same as item 19-72, but fixing only. Each 19-85 5805
Same as item 19-73, but fixing only. Each 19-86 5805
Same as item 19-74, but fixing only. Each 19-87 5805
Same as item 19-75, but fixing only. Each 19-88 7665
Same as item 18-76, but fixing only. Each 19-89 5805
Same as item 19-77, but fixing only. Each 19-90 4875
Same as item 19-78, but fixing only. Each 19-91 7665
Same as item 19-79, but fixing only. Each 19-92 5805
Same as item 19-80, but fixing only. Each 19-93 5805
Add to item 19-68 or 19-81, if removal only. Each 19-94 2959
Add to item 19-69 or 19-82, if removal only. Each 19-95 3656
Add to item 19-70 or 19-83, if removal only. Each 19-96 3656
Add to item 19-71 or 19-84, if removal only. Each 19-97 4354
Add to item 19-72 or 19-85, if removal only. Each 19-98 3656
Add to item 19-73 or 19-86, if removal only. Each 19-99 4354
Add to item 19-74 or 19-87, if removal only. Each 19-100 4354
Add to item 19-75 or 19-88, if removal only. Each 19-101 5749
Add to item 19-76 or 19-89, if removal only. Each 19-102 4354
Add to item 19-77 or 19-90, if removal only. Each 19-103 3656
Add to item 19-78 or 19-91, if removal only. Each 19-104 5749
Add to item 19-79 or 19-92, if removal only. Each 19-105 4354
Add to item 19-80 or 19-93, if removal only. Each 19-106 4354
Extra Column Pipe
Extra column pipe, with motor shaft (3 M length each), Each 19-107 57210
complete with bearing sockets, threaded coupling shaft,
sleeve and rubber bearing, complete set (125 mm x 3 m x 25
mm), supply and fixing.
Same as item 19-107, but size (150 mm x 3 m x 30 mm). Each 19-108 78690
Same as item 19-107, but size (150 mm x 3 m x 35 mm). Each 19-109 78690
Same as item 19-107, but size (175 mm x 3 m x 35 mm). Each 19-110 110805
Same as item 19-107, but size (175 mm x 3 m x 45 mm). Each 19-111 142065
Submersible Pump
Pumping set submersible, with AC electric motor driven, 400 Each 19-122 1533075
V, 3 phase, 50 cycles, complete with pump, motor, cable,
column pipes, motor control unit, pump capacity 0.5 cusec
upto 97 M head, pump setting 60 M with 25 HP motor, 2900
RPM, motor efficiency IE2, insulation class ’F’, enclosure
characteristics IP-68, supply and fixing.
Same as item 19-122, but pump capacity 0.5 cusec at 97-106 Each 19-123 1482675
M head, pump setting 60 M, with 30 HP motor, 2900 RPM.
Same as item 19-122, but pump capacity 1.0 cusec at 88-97 Each 19-124 2118476
M head, pump setting 50 M, with 50 HP motor, 2900 RPM.
Same as item 19-122, but pump capacity 1.0 cusec at 97-105 Each 19-125 2668556
M head, pump setting 60 M with 60 HP motor, 2900 RPM.
Same as item 19-122, but pump capacity 1.0 to 1.25 cusec, Each 19-126 2668556
96-110 M head, pump setting 60 M, with 60 HP motor, 2900
RPM.
Same as item 19-122, but pump capacity 1.50 cusec and upto Each 19-127 3017988
88 M head, pump setting 60 M with 75 HP motor, 2900 RPM.
Same as item 19-122, but pump capacity 1.25-1.50 cusec at Each 19-128 3017988
95-105 M head, pump setting 60 M with 75 HP motor 2900
RPM.
Same as item 19-122, but pump capacity 1.50 to 1.75 cusec Each 19-129 3018453
at 88-102 M head, pump setting 60 M with 75 HP motor,
2900 RPM.
Same as item 19-122, but pump capacity 1.75 cusec at 82-91 Each 19-130 3018453
M head, pump setting 60 M with 85 HP motor 2900 RPM.
Chlorinators
Gas Chlorinator "Imported" direct cylinder mounted, all Each 19-149 266499
vacuum operated, max capacity 25-50 pounds per day (ppd),
feed gas chlorination ratio 20:1, with all operational standard
accessories, make Pennsylvania USA , Model 201-CI, supply
and fixing.
Same as item 19-149, but Model 481-CI Each 19-150 169576
Same as item 19-149, but fixing only. Each 19-151 345
Same as item 19-150, but fixing only. Each 19-152 345
Add to item 19-149 or 19-151, if removal only. Each 19-153 259
Same as item 19-155, but motor capacity 5 HP. Each 19-156 85035
Reciprocating Pump
Reciprocating pump (donkey pump) 1450 RPM, driven with Each 19-169 11123
single phase electric motor 1/2 HP, mounted on frame and
fixed complete head 15-40 M, discharge 34-29 lit/min, supply
and fixing.
Same as item 19-169, but heavy duty driven by electric motor Each 19-170 31823
2 HP, SP head 30-70 M, discharge 50-39 lit/min.
Same items as 19-169 or 19-170, but fixing only. Each 19-171 803
Add to item 19-169, 19-170 or 19-171, if removal only. Each 19-172 602
Motor Electric
Motor electric, Motor Efficiency, single phase, 220V, 1/2 HP, Each 19-173 11153
1425 /1450 RPM, supply and fixing.
Motor electric, Motor Efficiency IE-2, Insulation Class F, Each 19-174 16673
Enclosure characteristic IP-55, single phase, 220V, 2 HP, 1425
/1450 RPM, supply and fixing.
Same as item 19-173 or 19-174, but fixing only. Each 19-175 173
Add to item 19-173, 19-174 or 19-175, if removal only. Each 19-176 129
Add to items 19-180 to 19-181 or 19-185, if removal only. Each 19-188 388
Add to items 19-182 to 19-183 or 19-186, if removal only. Each 19-189 698
Add to Item 19-200, 19-201 or 19-202, if removal only. Each 19-203 602
Same as item 20-114 but Reducer Y-T 110 mm x 160 mm dia. Each 20-116 2348
Supply and fix, uPVC Reducer T, 75 mm x 110 mm dia, Each 20-117 390
complete with solvent cement, all as specified.
Same as item 20-117 but 110 mm x 160 mm dia. Each 20-118 902
Supply and fix, uPVC Reducer Y-T, 110 mm x 160 mm dia, Each 20-119 1502
complete with solvent cement joint, all as specified.
Supply and fix, RCC pipes, 150 mm bore, laid and jointed with Metre 21-3 517
spigot socket or collars, as specified.
Same as Item 21-3, but except cost of pipes, collars fittings. Metre 21-4 175
Supply and fix, RCC pipes 230 mm bore, laid and jointed with Metre 21-5 713
spigot socket or collars, as specified.
Same as Item 21-5, but except cost of pipes, collars fitting. Metre 21-6 218
Surface Gullies
Excavate, to dispose off surplus spoil on site, make good the Each 21-19 2020
surface disturbed, supply (230 mm x 230 mm x 100 mm out
let), surface gullies and bed, and surround in 100mm of PCC
1:4:8, provide 100 mm x 125 mm rounded PCC 1:4:8, curb or
900 mm x 900 mm x100 mm dished PCC 1:4:8, top and 250 x
250 mm galvanized CI, loose grating, complete.
Testing Drains
Provide water and temporary apparatus, test drains till Each 21-20 700
perfect testing using (600 mm to 1800 mm head).
Provide water and temporary apparatus, test manholes, full Each 21-21 1431
depth of manholes, but not exceeding 1800 mm.
Provide apparatus, material, labour etc. and smoke test till Each 21-22 983
perfect testing of soil waste, ventilating pipes and connecting
drain to nearest manhole.
Clearing drains by rodding and well flushing between Each 21-23 1140
manholes not exceeding 30M.
Same as item 21-23, but manholes exceeding 30 M and not Each 21-24 1230
exceeding 92 M.
Manholes
Manholes, complete, rectangular or circular as described, not Cum 21-25 36267
exceeding 600 mm deep from invert to surface of cover,
including main channel, set in CM 1:1, 230 mm thick brick
walls (except manhole cover).
Same as item 21-25, but 300 mm thick stone walls. Cum 21-26 41574
Same as item 21-25, but 230 mm thick poured Concrete Cum 21-27 36230
walls.
Same as item 21-25, but 150 mm thick RCC walls. Cum 21-28 33058
Manholes, complete, rectangular or circular as described, Cum 21-29 30071
exceeding 600 mm deep but not exceeding 1800 mm deep,
with iron steps (in angles 380 mm centres), 230mm thick
brick walls (Except manhole cover).
Same as item 21-29, but 300 mm thick stone walls. Cum 21-30 30499
Same as item 21-29, but 230 mm thick poured Concrete Cum 21-31 29223
walls.
Same as item 21-29, but 150 mm thick RCC walls. Cum 21-32 24184
Manhole Covers
Supply and fix, Manhole CI cover with frame, 450 mm, Each 21-33 3346
circular or rectangular exceeding 7.50kg each, but not
exceeding 10kg/each, set in CM and haunching in Concrete,
as specified.
Taking up or down, manhole cover and frame, and removing Each 21-34 240
to store.
Providing and laying, RCC 1:2:4 Manhole cover (precast) Each 21-35 5960
complete with angle iron frame, embedded in concrete, all as
per Information Sheet # Svcs-341
Supply and fix, siphon traps, glazed ware in PCC 1:4:8, P or S Each 21-36 766
traps, 100 mm dia
Sinking of Well
Sinking of Well, 2.15 M dia, upto 3 M depth, below sub soil Metre 21-37 31750
water level.
Cutting into existing Manholes, for connecting new drains, Each 21-38 533
making good to pipe and rendering, cutting out existing
benching and reforming of benching as required for new
drain, making good to existing wall etc., complete, 100 mm
bore of pipes.
Same as item 21-38, but 150 mm bore of pipes. Each 21-39 610
Same as item 21-38, but 230 mm bore pipes. Each 21-40 687
Cutting into existing manholes for removing branch drains, Each 21-41 441
making good to walls and rendering, cutting out branch
channel, and making good benching complete, 100 mm bore
of pipes.
Same as item 21-41, but 150 mm bore of pipes. Each 21-42 481
Same as item 21-41, but 230 mm bore of pipes. Each 21-43 584
Taking up CC or Glazed ware pipes with or without collars, Metre 21-44 65
including fittings, removing to store or cleaning, and stacking
for relaying, 100 mm bore pipes.
Same as item 21-44, but 150 mm bore pipes. Metre 21-45 101
Same as item 21-44, but 230 mm bore pipes. Metre 21-46 125
Breaking up Glazed ware or RCC drain pipes set in CM and Metre 21-47 47
removing off the Mindef premises, if required, 100 mm bore
of pipes.
Same as item 21-47, but 150 mm bore of pipes. Metre 21-48 72
Same as item 21-47, but 230 mm bore of pipes. Metre 21-49 89
Taking up carefully, drain pipes fit for subsequent reuse, Metre 21-50 47
cleaning and stacking within 30M, 100 mm bore of pipes.
Same as item 21-56, but 150 mm bore of pipes. Each 21-57 186
Same as item 21-56, but 230 mm bore of pipes. Each 21-58 278
Sludge Pumps
Pumping set, submersible, Sewerage type, with AC electric Each 21-59 228300
motor 400V, 3phase, 50 cycles, capacity 14 cum / hour, head
30ft/9.14M, supply and fixing.
Same as item 21-59, but discharge 15 cum / hour, head Each 21-60 422177
60ft/18.30M.
Same as item 21-59, but discharge 16 cum / hour, head Each 21-61 767484
100ft/30M.
Same as item 21-59 to 21-61, but fixing only. Each 21-62 1155
Same as item 21-59 to 21-62, if removal only. Each 21-63 866
Providing and laying, pre-cast pre-stressed, RCC, Double Tee, Sqm 22-21 5152
size 1.524 M x 0.406 M, RCC roof panel (having web size
64mm x114mm and slab thickness 35 mm) span from 6.096
M to 7.925 M, including hoisting, complete, all as specified.
Same as item 22-21, but for span from 8.534 M to 9.754 M. Sqm 22-22 5152
Same as item 22-21 but for span from 10.363 M to 10.973 M. Sqm 22-23 5293
Same as item 22-21 but for span from 11.582 M to 12.192 M. Sqm 22-24 5433
Providing and laying, pre-cast pre-stressed, RCC, Inverted Tee Metre 22-27 18254
beam, size 0.305 M x 0.406 M x 0.254 M. For Double Tee
size, 1.524 M x 0.406 M, for span from 3.658 M to 6.096 M,
including hoisting, complete, all as specified.
Same as item 22-27, but for span from 6.401M to 8.534M. Metre 22-28 18815
‘L’ Beams
Providing and laying, pre-cast pre-stressed, RCC, L beam, size Metre 22-29 17332
0.305 M x 0.686 M x 0.254M. For Double Tee, size 3.048 M x
0.686M, for span from 3.658 M to 6.096 M, including
hoisting, complete, all as specified.
Same as item 22-29, but for span from 6.401 M to 8.534 M. Metre 22-30 17613
Providing and laying, pre-cast, pre-stressed, RCC, 'L' beam Metre 22-31 15829
size 0.305 M x 0.406 M x 0.254 M. For Double Tee, size 1.524
M x 0.406 M, for span from 3.658 M to 6.096 M, including
hoisting, complete, all as specified.
Same as item 22-31, but for span from 6.401 M to 8.534 M. Metre 22-32 16110
Boundary Wall
Providing and laying, pre-cast pre-stressed, RCC, "H" Section Metre 22-33 828
boundary wall, column size 102 mm x 229 mm, length 2.438
M to 3.658 M, complete, all as specified.
Same as item 22-33 but , column size 140 mm x 203 mm. Metre 22-34 1462
Providing and laying, pre-cast RCC boundary wall, coloured Metre 22-35 420
strip, 76 mm wide and 64 mm thick, all as specified.
Providing and laying, RCC pre-cast boundary wall column Each 22-36 472
caps, all as specified.
Steel ‘K’-Span
Supply and fix, Pre-Painted Galvanized Iron (PPGI) steel Sqm 22-37 1603
sheets for Steel 'K - Span from 6.096 M to 7.620 M using 0.5
mm, thick sheet @ 4.166 kg/sqm, complete, all as specified.
Same as item 22-37, but for span from 7.925 M to 9.144 M, Sqm 22-38 1887
using 0.6 mm thick sheet @ 4.941 kg/sqm
Same as item 22-37, but for span from 9.449 M to 10.668 M, Sqm 22-39 2148
using 0.7 mm thick sheet @ 5.705 kg/sqm.
Same as item 22-37, but for span from 10.973 M to 12.192 M Sqm 22-40 2416
using 0.8 mm thick sheet @ 6.480 kg/sqm.
Same as item 22-37, but for span from 12.497 M to 19.812 Sqm 22-41 2675
M, using 0.9 mm thick sheet @ 7.244kg/sqm.
Same as item 22-37, but for span from 20.117 M to 22.860 Sqm 22-42 2952
M, using 1.00 mm thick sheet @ 8.019kg/sqm.
Same as item 22-37, but for span from 22.860M to 25.908 M, Sqm 22-43 3457
using 1.2 mm thick sheet @ 9.548kg/sqm.
Same as item no. 22-37, but for span from 26.213 M to Sqm 22-44 3701
32.004 M using 1.3 mm thick sheet @ 10.323kg /sqm
Add to item 22-01 to 22-32, for hoisting for each subsequent Kg 22-45 4
4M or part thereof.
Add to item 22-37 to 22-44, for hoisting for each subsequent Kg 22-46 44
4M or part thereof.
Add to item 22-37 to 24-44, for transportation, for each Kg 22-47 44
subsequent 100 km or part thereof.
Providing and erecting Precast Hollow core slab size 1.292 M Sqm 22-48 4976
x 0.2 M for span 5.79 M to 6.4 M including hoisting, setting
and jointing in CM (1:4) all as specified.
Same as item 22-48 but for span 7.01 M to 8.23 M. Sqm 22-49 6258
Same as item 22-48 but for size 1.2192 M x 0.265 M for span Sqm 22-50 5675
7.01 M to 8.23 M, all as specified.
Same as item 22-50 but for span 8053 M to 9.75 M. Sqm 22-51 6661
Supply and fixing, fabrication and errection of LGS structure Sqm 22-52
upto required height and floor area as per user requirements
/ manufactures specifications, (Rate will be decided after
design / specifications).
Dismantle double tiling of brick or PCC in roof laid in CM, Sqm 23-24 216
including half bricks or blocks on edge, in any position.
Same as item 23-24, but of any other description, including Sqm 23-25 324
ridges, hips and valleys (net surface of roof area measured).
Finishing
Taking up or down, tiles / Marble / granite work of any type Sqm 23-26 180
laid in floors / walls etc.
Plumbing and Drains
Take down sheet lead in flats, gutters, dormers, flashing, Kg 23-27 4
ridges, hips cisterns, etc. and similar work (not to be paid
when gutters, ridges and hips are taken down as part of
roofing).
Same as item 24-5, but in Surface Flame proof conduit. Point 24-6 5270
Same as item 24-5, but in Concealed PVC conduit. Point 24-7 1627
Same as item 24-5, but in Surface PVC conduit. Point 24-8 2005
One fan point or one light point or one bell point, controlled Point 24-9 4058
by one switch, wiring complete, with PVC single core cable
1.5 mm², in Surface conduit, stove enamelled, supply and
fixing.
Same as item 24-9, but in Surface flame proof conduit. Point 24-10 5445
Same as item 24-9, but in Concealed PVC conduit. Point 24-11 1802
Same as item 24-9, but in Surface PVC conduit. Point 24-12 2180
Same as item 24-5 or 24-9, but fixing only. Point 24-13 1035
Same as item 24-6 or 24-10, but fixing only. Point 24-14 1035
Same as item 24-7 or 24-11, but fixing only. Point 24-15 375
Same as item 24-8 or 24-12, but fixing only. Point 24-16 690
Add to item 24-5, 24-9 or 24-13, if removal only. Point 24-17 345
Add to item 24-6, 24-10 or 24-14, if removal only. Point 24-18 345
Add to item 24-7, 24-11 or 24-15, if removal only. Point 24-19 289
Add to item 24-8, 24-12 or 24-16, if removal only. Point 24-20 345
One fan point or one light point or one bell point controlled Point 24-21 447
by one switch, wiring complete with PVC single/ core cable 1
mm2, but without PVC channel patty supply and fixing.
Same as item 24-35, but in Surface Flame proof conduit. Point 24-36 1429
Same as item 24-35, but in concealed PVC conduit. Point 24-37 747
Same as item 24-35, but in surface PVC conduit. Point 24-38 758
Add for each additional light point, bell point on same switch Point 24-39 1210
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1.5 mm²
in Surface conduit, stove enamelled, supply and fixing.
Same as item 24-39, but in Surface Flame proof conduit. Point 24-40 1604
Same as item 24-39, but in Concealed PVC conduit. Point 24-41 922
Same as item 24-39, but in Surface PVC conduit. Point 24-42 933
Same as item 24-35 or 24-39, but fixing only Point 24-43 259
Same as item 24-36 or 24-40, but fixing only Point 24-44 345
Same as item 24-37 or 24-41, but fixing only Point 24-45 345
Same as item 24-38 or 24-42, but fixing only. Point 24-46 345
Add to item 24-35, 24-39 or 24-43, if removal only. Point 24-47 129
Add to item 24-36, 24-40 or 24-44, if removal only. Point 24-48 173
Add to item 24-37, 24-41 or 24-45, if removal only. Point 24-49 173
Add to item 24-38, 24-42 or 24-46, if removal only. Point 24-50 173
Add for each additional light point, bell point on same switch Point 24-51 447
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1 mm2 ,
but without PVC Channel patty, supply and fixing.
Same as item 24-55, but in concealed PVC conduit. Point 24-57 533
Same as item 24-55, but in surface PVC conduit Point 24-58 533
Add for each additional light point, bell point on same switch Point 24-59 708
circuit/ additional circuit, controlled by more than one push
switch, wiring complete with PVC single core cable 1.5 mm,²
in Surface conduit, stove enamelled, but without conduit,
supply and fixing
Same as item 24-59, but in Surface, Flame proof conduit. Point 24-60 708
Same as item 24-59, but in Concealed PVC conduit. Point 24-61 708
Same as item 24-59, but in Surface PVC conduit. Point 24-62 708
Same as item 24-55 to 24-62, but fixing only. Point 24-63 259
Add to item 24-55 to 24-62 or 24-63, if removal only. Point 24-64 86
One light point, controlled by two ways switch, wiring Point 24-65 2314
2
complete with PVC single core cable 1 mm , on PVC Channel
patty, supply and fixing
Same as item 24-65, but 1.5 mm2 Point 24-66 2524
Same as item 24-65, 24-66 but fixing only. Point 24-67 1484
Add to item 24-65, 24-66 or 24-67, if removal only. Point 24-68 682
One light point controlled by two way switch, wiring Point 24-69 3353
complete with PVC single core cable 1 mm2 in Surface
conduit stove enamelled, supply and fixing.
Same as item 24-69, but in Surface Flame proof conduit. Point 24-70 4740
Same as item 24-69, but in Concealed PVC conduit. Point 24-71 1247
Same as item 24-69, but in Surface PVC conduit. Point 24-72 1593
One light point controlled by two way switch, wiring Point 24-73 3563
complete with PVC single core cable 1.5 mm² Surface
conduits, stove enamelled, supply and fixing.
Same as item 24-73, but in Surface Flame proof conduit. Point 24-74 4951
Same as item 24-73, but in Concealed PVC conduit. Point 24-75 1457
Same as item 24-73, but in Surface PVC conduit. Point 24-76 1803
Same as item 24-69, or 24-73, but fixing only. Point 24-77 1035
Same as item 24-70, or 24-74, but fixing only. Point 24-78 1035
Same as item 24-71, or 24-75, but fixing only. Point 24-79 375
Same as item 24-72 or 24-76, but fixing only. Point 24-80 690
Add to item 24-69, 24-73 or 24-77, if removal only. Point 24-81 345
Add to item 24-70, 24-74 or 24-78, if removal only. Point 24-82 345
Add to item 24-71, 24-75 or 24-79, if removal only. Point 24-83 465
Add to item 24-72, 24-76 or 24-80, if removal only. Point 24-84 345
One light point, controlled by two way switch, wiring, Point 24-85 674
complete, with PVC single core cable 1 mm2, but without
PVC Channel patty, supply and fixing
Same as item 24-85 but1.5 mm2 Point 24-86 884
Same as item 24-85, 24-86 but fixing only. Point 24-87 345
Add to item 24-85, 24-86 or 24-87 if removal only. Point 24-88 173
One light point controlled by two-way switch, wiring Point 24-89 674
complete with PVC single core cable 1 mm² in Concealed or
surface conduit but without conduit, supply and fixing.
One light point controlled by two way switch, wiring Point 24-90 794
complete with PVC single core cable 1.5 mm² in Concealed or
surface conduit, but without conduit, supply and fixing.
Same as item 24-89, 24-90 but fixing only. Point 24-91 345
Add to item 24-89, 24-90 or 24-91, if removal only. Point 24-92 173
Add for each additional light point on same switch circuit, Point 24-93 1555
wiring complete with PVC single core cable 1 mm2, with PVC
Channel patty, supply and fixing.
Same as item 24-93, but 1.5 mm2 24-94 1730
Same as item 24-93, 24-94 but fixing only. Point 24-95 690
Add to item 24-93, 24-94 or 24-95, if removal only Point 24-96 345
Add for each additional light point on same switch two way Point 24-97 1232
circuit, wiring complete with PVC single core cable 1 mm² in
Surface conduit, stove enamelled, supply and fixing.
Same as item 24-97, but in Surface flame proof conduit. Point 24-98 1804
Same as item 24-97, but in Concealed PVC conduit. Point 24-99 830
Same as item 24-97, but in Surface, PVC conduit. Point 24-100 811
Add for each additional light point on same switch 2 way Point 24-101 1517
circuit, wiring complete with PVC single core cable 1.5 mm² in
Surface conduit , stove enamelled, supply and fixing.
Same as item 24-101, but in Flame proof conduit. Point 24-102 1979
Same as item 24-101, but in Concealed PVC conduit. Point 24-103 1005
Same as item 24-101, but in Surface PVC conduit. Point 24-104 986
Same as item 24-97 or 24-101, but fixing only. Point 24-105 345
Same as item 24-98 or 24-102, but fixing only. Point 24-106 345
Same as item 24-99 or 24-103, but fixing only. Point 24-107 375
Same as item 24-100 or 24-104, but fixing only. Point 24-108 345
Add to item 24-97, 24-101 or 24-105, if removal only. Point 24-109 173
Add to item 24-98, 24-102 or 24-106, if removal only. Point 24-110 173
Add to item 24-99, 24-103 or 24-107, if removal only. Point 24-111 173
Add to item 24-100, 24-104 or 24-108, if removal only. Point 24-112 173
Add for each additional light point on same switch 2 way Point 24-113 674
2
circuit, wiring complete with PVC single core cable 1 mm ,
but without PVC Channel patty, supply and fixing.
Same as item 24-117, but in Concealed PVC conduit. Point 24-119 619
Same as item 24-117, but in Surface PVC conduit. Point 24-120 619
Add for each additional light point on Same switch 2-way Point 24-121 794
circuit, wiring complete with PVC single core cable 1.5 mm² in
Surface conduit, stove enamelled but without conduit, supply
and fixing.
Same as item 24-121, but in Surface Flame proof conduit. Point 24-122 794
Same as item 24-121, but in Concealed PVC conduit. Point 24-123 794
Same as item 24-121, but in Surface PVC conduit. Point 24-124 794
Same as item 24-117 to 24-124, but fixing only. Point 24-125 345
Add to item 24-117 to 24-124, or 24-125 if removal only. Point 24-126 173
One three pin socket outlet, 5 A, point controlled by one Point 24-127 2232
switch, wiring complete with PVC single core Cable 1 mm2 ,
with PVC Channel patty, including earth wire, supply and
fixing.
Same as item 24-129, but 1.5 mm2 Point 24-128 2407
Same as item 24-129, 24-130 but fixing only. Point 24-129 1035
Add to item 24-129, 24-130 or 24-131, if removal only Point 24-130 173
One three pin socket outlet, 5A, point controlled by one Point 24-131 3564
switch, wiring complete with PVC single core cable 1 mm², in
Surface conduit, enamelled including earth wire, supply and
fixing.
Same as item 24-131, but in Surface flame proof conduit. Point 24-132 4477
Same as item 24-131, but in Concealed PVC conduit. Point 24-133 2265
Same as item 24-131, but in Surface PVC conduit. Point 24-134 2112
One three pin socket outlet, 5 A, point controlled by one Point 24-135 3740
switch, wiring complete PVC with single core cable 1.5 mm²
in Surface conduit, stove enamelled, including earth wire,
supply and fixing.
Same as item 24-135, but in Surface Flame proof conduit. Point 24-136 4652
Same as item 24-135, but in Concealed PVC conduit. Point 24-137 2440
Same as item 24-135, but in Surface PVC conduit. Point 24-138 2287
One three pin socket outlet, 5 A, point controlled by one Point 24-139 792
switch, wiring complete with PVC single core cable, 1 mm2 ,
including earth wire, on PVC Channel patty, but without PVC
Channel patty, supply and fixing.
Same as item 24-139, but 1.5 mm2 Point 24-140 967
Same as item 24-139, 24-140 but fixing only. Point 24-141 518
Add to item 24-139, 24-140 or 24-141, if removal only Point 24-142 173
One three pin socket outlet, 5 A, point controlled by one Point 24-143 620
switch, wiring complete with PVC single core cable 1 mm², in
Concealed or Surface conduit, but without conduit and earth
wire, supply and fixing.
Same as item 24-143, but fixing only. Point 24-144 345
Add to item 24-143, or 24-144, if removal only. Point 24-145 173
One three pin socket outlet, 5 A, point controlled by one Point 24-146 794
switch, wiring complete with PVC single core cable 1.5 mm²,
in Concealed or Surface conduit but without conduit and
earth wire, supply and fixing.
Same as item 24-146 but fixing only. Point 24-147 345
Add to item 24-146 or 24-147, if removal only Point 24-148 173
One three pin socket outlet, 15 A, point controlled by one Point 24-149 2708
switch, wiring complete with PVC single core cable 2.5 mm2 ,
on PVC Channel Patty, including earth wire, supply and fixing.
Same as item 24-152, but in Concealed PVC conduit. Point 24-154 3127
Same as item 24-152, but in Surface PVC conduit. Point 24-155 3054
Same as item 24-131, 24-135 or 24-152, but fixing only. Point 24-156 1035
Same as item 24-132, 24-136 or 24-153, but fixing only. Point 24-157 1500
Same as item 24-133, 24-137 or 24-154 but fixing only. Point 24-158 1725
Same as item 24-134, 24-138 or 24-155, but fixing only. Point 24-159 1035
Add to item 24-131, 24-135, 24-152 or 24-156, if removal Point 24-160 690
only.
Add to item 24-132, 24-136, 24-153 or 24-157, if removal Point 24-161 690
only.
Add to item 24-133, 24-137, 24-154 or 24-158, if removal Point 24-162 690
only.
Add to item 24-134, 24-138, 24-155 or 24-159, if removal Point 24-163 690
only.
One three pin socket outlet, 15 A, point controlled by one Point 24-164 1279
switch, wiring complete with PVC single core cable 2.5 mm2 ,
but without PVC Channel Patty and earth wire,, supply and
fixing.
Same as item 24-164, but fixing only. Point 24-165 517
Add to item 24-164 or 24-165, if removal only. Point 24-166 172
One three pin socket outlet, 15 A, point controlled by one Point 24-167 1279
switch, wiring complete with PVC single core cable 2.5 mm²
copper conductor in Concealed or Surface conduit but
without conduit, and earth wire, supply and fixing.
Same as item 24-179, but without lamp holder Each 24-180 318
Same as item 24-179, but fixing only. Each 24-181 86
Same as item 24-180, but fixing only. Each 24-182 76
Same as item 24-179 to 24-182, if removal only. Each 24-183 52
Lamp Holder
Lamp holder, batten BC, with shade carrier ring, 20 mm, all Each 24-184 87
insulated reinforced linear, supply and fixing.
Same as item 24-184, but 45° angle Each 24-185 87
Lamp holder ES, CG, supply and fixing Each 24-186 87
Lamp holder ES, threaded 20 mm dia, ET, supply and fixing. Each 24-187 102
Lamp holder brass screw type for 500/300W Lamp, supply Each 24-188 184
and fixing
Same as item 24-184 to 24-188, but fixing only. Each 24-189 61
Add to item 24-184 to 24-188, or 24-189 if removal only. Each 24-190 30
LED Lights
LED strip light 2 feet, 18 watt 220/240 volts for wall or ceiling Each 24-191 786
mounted approved type Standard, Supply and fixing.
LED Recessed panel light, 6 watts 220/240 volts, round or Each 24-199 735
Square approved type Standard Supply and fixing.
Same as item 24-199 but Deluxe. Each 24-200 1005
Same as item 24-199 but Premium. Each 24-201 1289
LED Recessed panel light, 12 watts 220/240 volts, round or Each 24-202 1071
Square, approved type, Standard, Supply and fixing.
LED Surface Mounted panel light, 6 watts 220/240 volts, Each 24-213 657
round or Square, approved type Standard, Supply and fixing
LED Down light, 7 watts, 220/240 volts, approved type, Each 24-227 690
Standard, Supply and fixing.
Same as item 24-227 but Deluxe. Each 24-228 780
Same as item 24-227 but Premium. Each 24-229 840
LED Down light, 12 watts, 220/240 volts, approved type, Each 24-230 960
Standard Supply and fixing.
Same as item 24-230 but Deluxe Each 24-231 1146
Same as item 24-230 but Premium Each 24-232 1158
LED Down light, 18 watts, 220/240 volts, approved type, Each 24-233 1230
Standard. Supply and fixing.
Same as item 24-233 but Deluxe Each 24-234 1398
Same as item 24-233 but Premium Each 24-235 1758
Same as item 24-227 to 24-235, but fixing only. Each 24-236 259
Add to item 24-227 to 24-235 or 24-236, if removal only. Each 24-237 173
LED/SMD Bulb, 5 watts, 220/240 volts, approved type supply Each 24-238 203
and fixing
Same as item 24-238 but, 7 watts. Each 24-239 186
Same as item 24-238 but, 12 watts Each 24-240 207
Same as item 24-238 but, 18 watts Each 24-241 400
Same as item 24-238 but, 30 watts Each 24-242 609
Same as item 24-238 but, 50 watts Each 24-243 1175
Same as item 24-212 to 24-217, but fixing only. Each 24-244 35
Add to item 24-212 to 24-217 or 24-218, if removal only. Each 24-245 28
Switch SP, 5 A, Piano type single or two way mounted in cast Each 24-246 107
or malleable iron galvanize conduit box, with solid metal or
Bakelite plate, supply and fixing.
Same as item 24-246, but fixing only Each 24-247 76
Add to item 24-246 or 24-247, if removal only. Each 24-248 38
Switch water tight, SP, 5 A, galvanized, front side operated, Each 24-249 433
screwed, 20 mm, conduit terminal or through pattern, one
way, supply and fixing.
Same as item 24-249, but fixing only Each 24-250 121
Add to item 24-249 or 24-250, if removal only Each 24-251 61
Switch, SP, socket outlet 3 pin, 5 A, Universal/Multiple Each 24-252 183
Bakelite, shuttered pattern, complete, supply and fixing.
Same as item 24-252, but in galvanized, cast or malleable Each 24-253 378
iron, in lieu of Bakelite box
Same as item 24-252, 24-253, but fixing only. Each 24-254 121
Add to item 24-252, 24-253 or 24-254, if removal only. Each 24-255 61
Switch, SP, socket out let 3 pin, 15 A, shuttered pattern, Each 24-260 271
mounted in Bakelite box complete, supply and fixing.
Switch, SP, Socket outlet, 3 pins, 20 A, shuttered pattern, Each 24-261 348
mounted in Bakelite box, complete, supply and fixing.
Socket Outlet, Industrial 380/400 V, 3 phase, neutral and Each 24-265 1543
earth, water proof 16A, supply and fixing.
Same as item 24-265, but 32A. Each 24-266 1867
Same as item 24-265, but 63A. Each 24-267 5326
Same as item 24-265 to 24-267 but fixing only. Each 24-268 607
Add to item 24-265 to 24-267 or 24-268, if removal only. Each 24-269 304
Plug for Socket Outlet, Industrial 380/400 V, 3 phase, neutral Each 24-270 776
and earth, water proof, 16 A, supply and fixing.
Same as item 24-270, but 32 A Each 24-271 1124
Same as item 24-270, but 63 A Each 24-272 2975
Same as item 24-270 to 24-271, but fixing only. Each 24-273 182
Same as item 24-272, but fixing only Each 24-274 455
Add to item 24-270 to 24-271 or 24-273, if removal only. Each 24-275 91
Earthing
Earth, complete as described in Para 24.16 of the Each 24-283 5540
Specifications, with 8 SWG copper conductor, supply and
fixing.
Same as item 24-283, but with 6 SWG. Each 24-284 5989
Same as item 24-283, but with 2 SWG. Each 24-285 7406
Same as item 24-283, but with 3/0 SWG. Each 24-286 9769
Same as item 24-283 to 24-286, but fixing only. Each 24-287 2199
Add to item 24-283 to 24-286 or 24-287, if removal only. Each 24-288 379
Lightning Conductor
Air termination for Lightning Conductor, with 15 mm dia Each 24-289 3381
copper rod, 150 cm long, with gunmetal copper base, 75 mm
x 40 mm x 30 mm, fixed complete, with brass bolts, supply
and fixing.
Same as item 24-289, but fixing only. Each 24-290 304
Add to item 24-289 or 24-290, if removal only. Each 24-291 152
Down conductor, roof conductor and conductor required for Metre 24-292 1020
bonding exposed metal work to earthing conductor with
copper strips, 25 mm x 3 mm, supply and fixing.
Meter electric AC 400 volts, 3 phase, 50 cycle, 4 wire, 15-90 Each 24-306 10117
A, supply and fixing.
Same as item 24-306, but 100 A Each 24-307 10117
Same as item 24-306, but 200 A complete with CTs Each 24-308 23351
Digital Electric Meter (TOU) AC 400 volts, 3 phase, 50 cycle, 4 Each 24-309 19471
wire, 15-90 A, supply and fixing.
Same as item 24-309, but 100 A. Each 24-310 19471
Same as item 24-309 but 200 A, complete with CTs. Each 24-311 28991
Same as item 24-306, to 24-307 or 24-309 to 24-310, but Each 24-312 759
fixing only.
Same as item 24-308 or 24-311, but fixing only. Each 24-313 911
Add to item 24-306 to 24-313, if removal only. Each 24-314 380
Smart Meters
Supply and fixing of Static 3-Phase, whole current Smart Each 24-315 20111
energy meter DLMS/COSEM complaint (TOD/TOU) with built
in GSM/GPRS communication Module, Measuring the
parameters i.e active power KWH, reactive power KVARH,
Phase volts, Phase current, MDI, etc Power factor and
demand/schedual automatic meter reading i.e hourly, daily
weekly monthly, 440 volt, 3 Phase, four wire, 50HZ all as
specified.
Same as item 24-315, but single Phase 220/240 volts Each 24-316 10511
Same as item 24-315, 24-316 but fixing only Each 24-317 911
Add to item 24-315, 24-316 or 24-317, if removal only. Each 24-318 455
Switch fuse Flame proof, SP, 250 V, 15 A, terminal chamber Each 24-327 6190
drilled and tapped, 25 mm ET on both sides, solid brass
threaded plug for sealing hole not required, supply and fixing
(The complete unit should comply with BSS No 229, 542 and
889).
Same as item 24-327, but 250/500 V, 30 A Each 24-328 7210
Same as item 24-327, but TPNL, 500 V, 15 A Each 24-329 10207
Same as item 24-327, but TPNL, 500 V, 30 A Each 24-330 17407
Same as item 24-327, but TPNL, 500 V, 60 A Each 24-331 25063
Same as item 24-327, but TPNL, 500 V, 100 A Each 24-332 36447
Same as item 24-327, but TPNL, 500 V, 200 A Each 24-333 62544
Same as item 24-327, but TPNL, 500 V, 300 A Each 24-334 79980
Same as item 24-327, but fixing only Each 24-335 190
Same as item 24-328, but fixing only Each 24-336 190
Same as item 24-329, but fixing only Each 24-337 607
Same as item 24-330, but fixing only Each 24-338 607
Same as item 24-331 or 24-332, but fixing only Each 24-339 1063
Same as item 24-333 or 24-334, but fixing only Each 24-340 1518
Add to item 24-327, 24-328, 24-335 or 24-336, if removal Each 24-341 95
only
Add to item 24-329, 24-330, 24-336 or 24-337, if removal Each 24-342 304
only
Add to item 24-331 to 24-332 or 24-338, if removal only Each 24-343 531
Add to item 24-333, 24-334 or 24-339, if removal only Each 24-344 759
Flame proof fitting, 20 mm ET tapped entry, CI body, grey Each 24-345 4203
painted, with heavy glass cemented to fixed ring, strong wire
guard and lamp holder with terminal chamber, internal
connections of solid metal passing through insulating sleeves
dispersive or angle type, vitreous enamelled reflector, over all
height 300 mm and overall dia 175 mm, suitable for 60/100
W lamp, supply and fixing.
Same as item 24-345, but rectangular, approved type, Each 24-346 7172
suitable to take upto 150W lamp.
Same as item 24-345 or 24-346, but fixing only. Each 24-347 152
Add to item 24-345, 24-346 or 24-347 if removal only. Each 24-348 76
Spare glass and ring for item 24-345 or 24-346, supply and Each 24-349 796
fixing.
Same as item 24-349, but fixing only. Each 24-350 76
Add to item 24-349 or 24-350, if removal only. Each 24-351 38
Switch Fuses
Change over switch, 15 A, SP, 250 V, 50 cycles, DP, wall Each 24-352 1052
mounted type, supply and fixing.
Same as item 24-352 but 30 A Each 24-353 1652
Change over switch, 30 A, TP with NL, wall mounted type, Each 24-354 3900
supply and fixing.
Same as item 24-354, but 60 A. Each 24-355 5594
Same as item 24-354, but 100 A. Each 24-356 8798
Same as item 24-354, but 200 A. Each 24-357 16361
Same as item 24-354, but 300 A. Each 24-358 18641
Same as item 24-354, but 400 A. Each 24-359 33813
Same as item 24-354, but 500 A. Each 24-360 42717
Same as item 24-352 to 24-355, but fixing only. Each 24-361 345
Same as item 24-356 to 24-358, but fixing only. Each 24-362 518
Same as item 24-359 to 24-360, but fixing only. Each 24-363 690
Add to item 24-352 to 24-355 or 24-360, if removal only. Each 24-364 259
Add to item 24-356 to 24-360 or 24-362, 24-363, if removal Each 24-365 455
only.
MCCBs SP
MCCB, SP, 6 to 63 A. (Breaking capacity 6 KA), supply and Each 24-366 540
fixing
Same as item 24-366 but double pole. Each 24-367 1383
Circuit breaker, built in plug type, 3 pin (Breaking capacity 6 Each 24-368 898
KA) 6 to 20 A, supply and fixing.
Same as item 24-366 to 24-368, but fixing only. Each 24-369 86
Add to item 24-366 to 24-368 or 24-369 if removal only. Each 24-370 57
MCCB 3 Pole
MCCB, 3 Pole 500/600 V, 50/60 cycles, complete with Each 24-371 4853
thermal and magnetic trips, 3 to 30 A, (breaking capacity 2.5
KA), supply and fixing.
Same as item 24-371, but 40 to 50 A. Each 24-372 5086
Same as item 24-371, but 15 to 60 A (breaking capacity 5 KA). Each 24-373 5213
Same as item 24-371, but 75 to 100 A (breaking capacity 5 Each 24-374 6078
KA).
Same as item 24-371, but 125 to 225 A (breaking capacity 18 Each 24-375 11958
KA).
Same as item 24-371, but 250 to 400 A (breaking capacity 25 Each 24-376 14167
KA).
Same as item 24-371, but 500 to 600 A (breaking capacity 25 Each 24-377 55118
KA)
Same as item 24-371, but 800 A with external handle Each 24-378 59970
(breaking capacity 45 KA).
Same as item 24-371, but 1000 A with external handle Each 24-379 164490
(breaking capacity 85 KA)
Same as item 24-371, but 1250 A with external handle Each 24-380 181290
(breaking capacity 85 KA)
Same as item 24-371, 24-372 or 24-373, but fixing only. Each 24-381 173
Same as item 24-374 or 24-375, but fixing only. Each 24-382 259
Same as item 24-376 or 24-377, but fixing only. Each 24-383 518
Same as item 24-378 to 24-380, but fixing only Each 24-384 690
Add to item 24-371 to 24-373 or 24-381, if removal only. Each 24-385 114
Add to item 24-374 to 24-375, or 24-382, if removal only. Each 24-386 171
Add to item 24-376 to 24-377 or 24-383, if removal only. Each 24-387 342
Add to item 24-378 to 24-380 or 24-384, if removal only. Each 24-388 342
MCCB 4 Pole
MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with Each 24-389 8378
thermal and magnetic trip 3 to 30 A (Breaking capacity 2.5
KV), supply and fixing.
Same as item 24-389 but 40 to 50 A. Each 24-390 8378
Same as item 24-389 but 60 to 100 A. Each 24-391 8378
Same as item 24-389 but 125 A. Each 24-392 10515
Same as item 24-389 but 160 to 250 A breaking capacity. Each 24-393 14618
Same as item 24-389 but 300 to 400 A (Breaking capacity 50 Each 24-394 36415
KA).
Same as item 24-389 but 500 to 630 A (Breaking capacity 50 Each 24-395 51800
KA).
Same as item 24-389 but 800 A with external handle Each 24-396 87869
(Breaking capacity 50 KA).
Same as item 24-396 but 1000 A (Breaking capacity 70 KA). Each 24-397 144280
Add to item 24-392 to 24-393 or 24-400 if removal only. Each 24-404 171
Add to item 24-394 to 24-395 or 24-401 if removal only. Each 24-405 342
Add to item 24-396 to 24-398 or 24-402 if removal only. Each 24-406 449
Earth leakage circuit breakers, 4 pole, 500/660 V, 50/60 Each 24-407 37781
cycle, complete with earth leakage, over load and short
circuit protection, 15 to 100 A (breaking capacity 14 KA, at
415 V), supply and fixing.
Same as item 24-407, but 200 A (breaking capacity 35 KA). Each 24-408 62191
Conduit
Conduit 20 mm dia, heavy gauge Class-"B", screwed, Metre 24-419 248
complete with bends, tees, boxes, saddles etc, stove
enamelled for Surface wiring, supply and fixing.
Same as item 24-419, but 25 mm dia. Metre 24-420 290
Same as item 24-419, but 40 mm dia. Metre 24-421 426
Same as item 24-419, but 50 mm dia. Metre 24-422 675
Same as item 24-419, or 24-420, but fixing only Metre 24-423 86
Same as item 24-421 or 24-422, but fixing only. Metre 24-424 104
Add to item 24-419, 24-420 or 24-423, if removal only. Metre 24-425 57
Conduit 20 mm dia, heavy gauge Class "B" screwed complete Metre 24-427 523
with all bends, tees, boxes, saddles etc, stove enamelled for
Concealed wiring, supply and fixing.
Same as item 24-427, but 25 mm dia. Metre 24-428 565
Same as item 24-427, but 40 mm dia. Metre 24-429 695
Same as item 24-427, but 50 mm dia. Metre 24-430 943
Same as item 24-427 or 24-428, but fixing only. Metre 24-431 328
Same as item 24-429 or 24-430, but fixing only. Metre 24-432 328
Add to item 24-427, 24-428 or 24-431, if removal only. Metre 24-433 178
Add to item 24-429 to 24-430 or 24-432, if removal only. Metre 24-434 196
PVC conduit, 20 mm dia, complete with all bends, tees, Metre 24-435 134
boxes, saddles etc for Surface wiring, and concealed wiring,
supply and fixing.
Same as item 24-435, but 25 mm dia. Metre 24-436 154
Same as item 24-435, but 40 mm dia. Metre 24-437 270
Same as item 24-435, but 50 mm dia. Metre 24-438 357
Same as item 24-435 or 24-436, but fixing only Metre 24-439 72
Same as item 24-437 or 24-438, but fixing only. Metre 24-440 86
Add to item 24-435, 24-436 or 24-439, if removal only. Metre 24-441 45
Conduit, 20 mm dia, heavy gauge Class-"B", screwed, solid Metre 24-444 456
drawn, complete with all bends, tees, boxes saddels etc.,
stove enamelled for surface wiring, supply and fixing (fittings
shall be flame proof and conform to BS No. 229 and 889).
Bell Push, 3A, 250 V, supply and fixing. Each 24-450 140
Same as item 24-450, but fixing only. Each 24-451 35
Add to item 24-450 or 24-451, if removal only. Each 24-452 21
Electric bell, AC/DC, Bakelite case, pressed iron frame, steel Each 24-453 326
contact spring and nickel plated, brass contact pillars both
having silver contact points round and nickel / CP steel gong,
supply and fixing.
Same as item 24-453, but fixing only. Each 24-454 52
Add to item 24-453 or 24-454, if removal only. Each 24-455 34
Buzzer, Bakelite case, suitable for operation on AC/DC, main Each 24-456 218
supply 100/110 V and 200/250 V, supply and fixing.
Fan electric with copper winding, blades, canopy and rod Each 24-465 5247
including connection, provision of cable and ceiling rose, for
fan 140 cm and 120 cm sweep, without regulator “Standard”,
supply and fixing.
Same as item 24-465 but Deluxe. Each 24-466 5606
Same as item 24-465, but Premium. Each 24-467 7842
Same as item 24-465, but 90 cm sweep. Each 24-468 3530
Fan electric, Water proof with copper winding blades, Each 24-469 4864
canopy and rod including connection, provision of cable and
ceiling rose for fan, 140 and 120 cm sweep, (without
regulator) of approved type, supply and fixing.
Fan electric, Energy Efficient with remote control, AC/DC 220 Each 24-470 5873
V, copper winding, blades, canopy and rod including
connection, provision of cable and ceiling rose for fan, 140
and 120 cm sweep, (without regulator) of approved type,
supply and fixing.
Same as item 24-465 to 24-470, but fixing only. Each 24-471 259
Add to item 24-465 to 24-470 or 24-471, if removal only. Each 24-472 169
Cassette Fan AC
Cassette type fan 2’ x 2’ with copper winding & remote Each 24-481 7755
control, including connection, provision of cable best quality
supply and fixing.
Same as item 24-481, but fixing only. Each 24-482 104
Add to item 24-481 or 24-482, if removal only. Each 24-483 52
Switch/Socket
Switch, SP, Bakelite, Piano type, 5 A, all insulated, one way, Each 24-484 102
supply and fixing.
Switch, SP, Bakelite, Piano type, 5 A, all insulated two ways, Each 24-485 94
supply and fixing.
Socket outlet, 5 A, Bakelite, 2-pin, concealed type, supply and Each 24-486 88
fixing.
Dimmer, for ceiling fan, any sweep supply and fixing. Each 24-487 196
Same as item 24-484 to 24-487, but fixing only. Each 24-488 52
Add to item 24-484 to 24-487 or 24-488, if removal only. Each 24-489 26
Electric Motors
Motor electric AC, 400 V, 3 phase, 50 cycles, 1450 / 2900 Each 24-490 44624
RPM, 1 HP, solid shaft horizontal, motor efficiency class IE-2,
Insulation class F & Enclosure class IP55, supply and fixing.
Add to item 24-495 to 24-497 or 24-508, if removal only. Each 24-514 654
Add to item 24-498 to 24-500 or 24-509, if removal only. Each 24-515 1480
Add to item 24-501 to 24-502 or 24-510, if removal only. Each 24-516 1480
Add to item 24-503 to 24-504 or 24-511, if removal only Each 24-517 1705
Add to item 24-505 to 24-506 or 24-512, if removal only. Each 24-518 2158
Rewinding
Rewinding of electric motor, SP, 50 cycle, 220/230 V, with Each 24-519 2564
copper insulated conductor complete, upto 1/2 HP.
Same as item 24-519, but over 1/2 HP and upto 1 HP. Each 24-520 4200
Same as item 24-519, but over 1 HP and upto 2 HP. Each 24-521 6000
Rewinding of electric motor, AC, 400 V, 3 phase, 50 cycles, Each 24-522 4200
1450/2900 RPM, complete as per original winding with
copper insulated conductor upto 1 HP.
Same as item 24-522, but over 1 HP and upto 3 HP. Each 24-523 6000
Same as item 24-522, but over 3 HP and upto 5 HP. Each 24-524 7200
Same as item 24-522 but over 5 HP and upto 7.5 HP. Each 24-525 12000
Same as item 24-522 but over 7.5 HP and upto 10 HP. Each 24-526 15385
Same as item 24-522 but over 10 HP and upto 15 HP. Each 24-527 21026
Same as item 24-522 but over 15 HP and upto 20 HP. Each 24-528 25128
Same as item 24-522 but over 20 HP and upto 25 HP. Each 24-529 29231
Same as item 24-522 but over 25 HP upto 30 HP. Each 24-530 37436
Same as item 24-522 but over 30 HP upto 40 HP. Each 24-531 44615
Same as item 24-522 but over 40 HP upto 50 HP. Each 24-532 55897
Same as item 24-522 but over 50 HP upto 60 HP. Each 24-533 64821
Same as item 24-522 but over 60 HP upto 70 HP. Each 24-534 75590
Same as item 24-522 but over 70 HP upto 80 HP. Each 24-535 86400
Rewinding of Ceiling fan, AC 220/ 230 V, 50 cycles, 140 cm Each 24-536 1920
sweep, complete as per original winding with copper
insulated conductor.
Same as item 24-536, but 120 cm sweep. Each 24-537 1846
Same as item 24-536, but 90 cm sweep. Each 24-538 1846
Starters
Direct Online starter, for motor, AC 400 V, 3 phase, 50 cycles, Each 24-539 5745
upto 5HP incl connecting up with incoming and outgoing
cables, supply and fixing.
Same as item 24-539, but fixing only. Each 24-540 345
Add to item 24-539 or 24-540, if removal only. Each 24-541 173
Auto Star Delta starter, for electric motor, AC 400 V, 3 phase, Each 24-542 40953
50 cycles, 7.5 to 10 HP, including connecting up with
incoming and outgoing cables, supply and fixing.
Same as item 24-542 but for 15 HP. Each 24-543 42518
Same as item 24-542, but for 20 HP. Each 24-544 44744
Same as item 24-542 but for 25 HP. Each 24-545 47692
Same as item 24-542 but for 30 HP. Each 24-546 53589
Same as item 24-542, but for 40 HP. Each 24-547 57897
Same as item 26-503, but for 50 HP. Each 24-548 66742
Same as item 24-542, but for 60 HP Each 24-549 71797
Same as item 24-542, but for 80 HP Each 24-550 95805
Same as item 24-542 but for 100 /125 HP. Each 24-551 127035
Same as item 24-542 to 24-546, but fixing only. Each 24-552 518
Same as item 24-547 to 24-551, but fixing only. Each 24-553 1035
Add to item 24-542 to 24-551 or 24-552, 24-553, if removal Each 24-554 431
only.
Conduit System
Bend / elbow, 20 mm dia, any type, cast or malleable iron, Each 24-555 109
stove enamelled or galvanized, supply and fixing.
Same as item 24-555, but 25 mm dia. Each 24-556 129
Same as item 24-555, but 40 mm dia. Each 24-557 222
Same as item 24-555, but 50 mm dia. Each 24-558 278
Junction Box circular, cast or malleable iron, stove enamelled Each 24-559 118
or galvanized, complete with cover, any number of outlets,
20 mm dia, supply and fixing.
Same as item 24-559, but 25 mm dia. Each 24-560 142
Same as item 24-559, but 40 mm dia. Each 24-561 250
Same as item 24-559, but 50 mm dia. Each 24-562 316
Junction Boxes/Board, rectangular 75x75 mm, cast or Each 24-563 160
melleable iron, stove enamelled or galvanized, complete with
cover, supply and fixing.
Same as item 24-563 but 75 x 100 mm. Each 24-564 184
Same as item 24-563 but 75 x 150 mm. Each 24-565 202
Same as item 24-563, but 100 x 175 mm. Each 24-566 202
Same as item 24-563, but 200 x 250 mm. Each 24-567 243
Same as item 24-563, but 250 x 300 mm. Each 24-568 261
Same as item 24-555 to 24-558, but fixing only. Each 24-569 52
Same as item 24-559 to 24-566, but fixing only. Each 24-570 52
Same as item 24-567 or 24-568, but fixing only. Each 24-571 69
Add to item 24-555 to 24-558 or 24-569, if removal only. Each 24-572 31
Thimble cable socket, for single core cable, 6 mm², to 16 Each 24-589 91
mm2 supply and fixing.
Same as item 24-589, but for 25 mm² Each 24-590 97
Same as item 24-590, but for 35 mm Each 24-591 105
Same as item 24-591, but for 50 mm² Each 24-592 143
Same as item 24-591, but for 70 mm² Each 24-593 161
Same as item 24-591, but for 95 mm² Each 24-594 230
Same as item 24-591, but for 120 mm² Each 24-595 248
Same as item 24-591, but for 150 mm² Each 24-596 361
Same as item 24-591, but for 185 mm² Each 24-597 420
Same as item 24-591, but for 240 mm² Each 24-598 612
Same as item 24-591, but for 300 mm² Each 24-599 836
Same as item 24-589 to 24-591 but fixing only. Each 24-600 69
Same as item 24-592 to 24-593 but fixing only. Each 24-601 86
Same as item 24-594 to 24-595 but fixing only. Each 24-602 104
Same as item 24-596 to 24-597 but fixing only. Each 24-603 121
Same as item 24-598 to 24-599, but fixing only. Each 24-604 138
Add to item 24-589 to 24-593 or 24-600, 24-601 if removal Each 24-605 35
only.
Add to item 24-594 to 24-595 or 24-602, if removal only. Each 24-606 52
Wiring
Wiring in conduit surface, concealed, flame proof, with single Metre 24-609 46
core PVC insulated cable, installed and connected complete
(excluding conduit) single core cable, 1 mm², supply and
fixing.
Same as item 24-609, but 1.5 mm² cable. Metre 24-610 58
Same as item 24-609, but 2.5 mm² cable. Metre 24-611 78
Same as item 24-609, but 4mm² cable. Metre 24-612 99
Same as item 24-609, but 6 mm² cable. Metre 24-613 131
Same as item 24-609, but 10 mm² cable. Metre 24-614 203
Same as item 24-609, but 16mm² cable. Metre 24-615 289
Same as item 24-609, but 25 mm² cable. Metre 24-616 442
Same as item 24-609, but 35 mm² cable. Metre 24-617 575
Same as item 24-609, but 50 mm² cable. Metre 24-618 773
Same as item 24-609, but 70 mm² cable. Metre 24-619 1101
Same as item 24-609 to 24-614, but fixing only. Metre 24-620 28
Same as item 24-616 to 24-619, but fixing only. Metre 24-621 86
Add to item 24-609 to 24-614 or 24-620, if removal only. Metre 24-622 14
2
Cable 3 core 1 mm copper conductor PVC insulated cable Metre 24-632 126
complete (excluding conduit), supply and fixing.
2 Metre 24-633 165
Same as item 24-632 but 1.5 mm
Same as item 24-632 but 2.5 mm² Metre 24-634 218
Same as item 24-632 but 4 mm² Metre 24-635 303
Same as item 24-632, but 6 mm² Metre 24-636 417
Same as item 24-632, but 10 mm² Metre 24-637 666
Same as item 24-632 to 24-637, but fixing only. Metre 24-638 35
Add to item 24-632 to 24-637 or 24-639, if removal only. Metre 24-639 17
Cable 4 core PVC insulated cable complete, (excluding of Metre 24-640 186
conduit) 1.5 mm2.
Same as item 24-640 but 2.5 mm² Metre 24-641 285
Same as item 24-640 but 4 mm² Metre 24-642 421
Same as item 24-640 but 6 mm² Metre 24-643 539
Same as item 24-640 but 10 mm² Metre 24-644 847
Same as item 24-640 to 24-644, but fixing only. Metre 24-645 35
Add to item 24-640 to 24-644 or 24-645, if removal only. Metre 24-646 17
Flexible Cable 3 Core 300/500 V 23/0.0076 supply and fixing Metre 24-654 114
Flexible Cable 4 Core 300/500 V 23/0.0076 supply and fixing Metre 24-661 129
Television Coaxial cable 0.8mm2 SC, 2V, 75 ohm, RG 6 Supply Metre 24-677 67
& fixing.
Same as item 24-677 but RG 7 Metre 24-678 135
Same as item 24-677 but RG 11 Metre 24-679 160
Same as item 24-677 to 24-679, but fixing only. Metre 24-680 52
Add to item 24-677 to 24-679 or 24-680, if removal only. Metre 24-681 35
Step light Led, Aluminium die cast body, with grill and milky Metre 24-682 2236
glass 220/240 V, 3 watt, complete, supply & fixing.
Fan electric, AC, Exhaust, with copper winding, 30 cm, Flame Each 24-711 9664
proof, 220/230 V, SP, complete, supply and fixing.
Air Compressors
Air compressor, single stage air cooled, mounted with Each 24-716 194310
horizontal receiving tank 300 lit capacity, max pressure 10
Kg/Cm2 (142 Psi), 3 cylinders, piston displacement 54.30 cfm,
fitted with auto pressure switch, pressure gauge and AC
electric motor 10 HP, 400 V, 3 phase, 50 cycles, supply and
fixing.
Same as item 24-716 but tank capacity 250 lit, 2 cylinders, Each 24-717 146310
displacement 39.50 cfm, with 7.5 HP electric motor.
Same as item 24-716, but tank capacity 160 lit, 3 cylinders, Each 24-718 116310
displacement 26.50 cfm, with 5 HP electric motor.
Same as item 24-716, but tank capacity 120 lit, 2 cylinders, Each 24-719 80310
displacement 16.40 cfm, with 3 HP electric motor.
Same as item 24-716, but tank capacity 100 lit, 2 cylinders, Each 24-720 76710
displacement 10.60 cfm, with 2 HP electric motor.
Same as item 24-716, but tank capacity 90 lit, 2 cylinders, Each 24-721 51810
displacement 8.50 cfm, with 1 HP electric motor single phase.
Same as item 24-721, but tank capacity 60 lit, 2 cylinders, Each 24-722 40710
displacement 3.7 cfm, with 0.5 HP electric motor.
Same as item 24-721, but tank capacity 300 lit, pressure 16 Each 24-723 170310
Kg/Cm2 (228 Psi) 3 cylinders, piston displacement 38.50 cfm
with 10 HP electric motor.
Same as item 24-723, but tank capacity 300 lit, 2 cylinders, Each 24-724 170310
displacement 26.30 cfm, 7.5 HP, Electric motor.
Same as item 24-724, but tank capacity 160 lit, 2 cylinders, Each 24-725 116310
displacement 20.40 cfm, 5 HP, Electric motor.
Same as item 24-716 to 24-725, but fixing only. Each 24-726 2310
Add to item 24-716 to 24-725 or 24-726, if removal only. Each 24-727 923
Electric Geyser
Electric Geyser, 27 lit capacity, complete with thermostat, Each 24-737 11955
safety valve, supply and fixing.
Same as item 24-737, but 36 lit capacity. Each 24-738 12138
Same as item 24-737, but 45 lit capacity. Each 24-739 13242
Same as item 24-733 to 24-739, but fixing only. Each 24-740 915
Add to item 24-735 to 24-739 or 24-740, if removal only. Each 24-741 686
Instant Electric Water Geyser, capacity 6 lit/min, complete Each 24-742 12195
supply & fixing.
Same as item 24-742 but 8 liters. Each 24-743 15075
Same as item 24-742 but 10 liters. Each 24-744 15315
Same as item 24-742 to 24-744 but fixing only. Each 24-745 915
Add to item 24-742 to 24-744 or 24-745 if removal only. Each 24-746 630
Distribution Board, steel sheet (16 BG) with hinged over, Sqm 24-747 28118
having locking arrangement, enamel painted, suitable for
housing of different capacities of MCCBs etc (as required),
supply and fixing.
Same as item 24-747, but fixing only. Sqm 24-748 518
Add to item 24-747 or 24-748, if removal only. Sqm 24-749 345
Wiring in PVC Channels
PVC channel rectangular, 20 mm complete for (surface Metre 24-750 192
wiring), supply and fixing.
Same as item 24-750, but 25 mm. Metre 24-751 287
Same as item 24-750 but 40 mm Metre 24-752 352
Same as item 24-750, but 50 mm. Metre 24-753 520
Same as item 24-750, but 65 mm. Metre 24-754 610
Same as item 24-750, but 75 mm. Metre 24-755 697
Same as item 24-750, but 100 mm. Metre 24-756 925
Same as item 24-750 to 24-753 but fixing only. Metre 24-757 86
Same as item 24-754 to 24-756 but fixing only. Metre 24-758 173
Add to item 24-750 to 24-756 or 24-757, 24-758 if removal Metre 24-759 69
only.
Gang Switch Series (Standard)
One gang switch, 10 A, 250 V, including PVC/steel back box Each 24-760 338
with proper screws supply and fixing.
Same as item 24-760, but 2 gang, 10 A. Each 24-761 454
Same as item 24-761, but 3 gang, 10 A. Each 24-762 535
Same as item 24-762, but 4 gang, 10 A. Each 24-763 614
Same as item 24-763, but 6 gang, 10 A. Each 24-764 835
Same as item 24-764, but 8 gang, 10 A. Each 24-765 1087
One gang switch, 2 way 10 A, 250 V, including PVC/steel back Each 24-766 404
box with proper screws supply and fixing.
Gang fan dimmer 10 A, 250 V, including PVC/steel back box Each 24-767 336
with proper screws supply and fixing.
Gang TV/ Telephone socket, shuttered, including PVC/steel Each 24-768 470
back box with proper screws supply and fixing.
Twin TV/ Telephone socket, shuttered, including PVC/steel Each 24-769 525
back box with proper screws supply and fixing.
Single switch, one way, 10 A, 250 V gang type, including Each 24-770 217
PVC/steel back box with proper screws supply and fixing.
One socket 2 pin 10 A, 250 V, gang type, including PVC/steel Each 24-773 378
back box with proper screws supply and fixing.
Dimmer for fan 250 V, including PVC/steel back box with Each 24-774 217
proper screws supply and fixing
TV / Telephone socket (gang type), including PVC/steel back Each 24-775 464
box with proper screws supply and fixing.
Ten gang switch 10 A 250 volts Complete, including PVC/steel Each 24-776 1207
back box with proper screws Supply & fixing
Same as item 24-776, but , 9 Switch +1 socket Each 24-777 1133
Same as item 24-776, but 8 Switch +2 socket Each 24-778 1133
Same as item 24-776, but 7 Switch +1 socket Each 24-779 1016
Same as item 24-776, but , 6 Switch +2 socket Each 24-780 1016
Same as item 24-776, but 5 Switch +1 socket Each 24-781 905
Same as item 24-776, but 4 Switch +2 socket Each 24-782 905
Same as item 24-776, but 3 Switch +3 socket Each 24-783 1010
Same as item 24-776, but 4 Switch +4 socket Each 24-784 1150
Same as item 24-776, but 1 Switch +1 socket Each 24-785 565
Same as item 24-776, but 2 Switch +1 socket Each 24-786 551
Same as item 24-776, but 1 Switch +2 socket Each 24-787 649
Same as item 24-776, but 2 Switch +2 socket Each 24-788 649
Same as item 24-776, but 3 Switch +1 socket Each 24-789 649
Same as item 24-760 to 24-789, but fixing only. Each 24-790 173
Add to item 24-760 to 24-789 or 24-790, if removal only. Each 24-791 104
Multi socket Light Plug, 10A, 250 V including PVC / steel back Each 24-792 693
box with proper screws Complete, supply and fixing.
Gang Power Socket, 15A, 250 V including PVC/steel back box Each 24-793 594
with proper screws complete, supply & fixing.
Gang Single Telephone Socket Complete, including PVC/steel Each 24-794 468
back box with proper screws supply & fixing.
Gang Double Telephone Socket Complete, including Each 24-795 474
PVC/steel back box with proper screws, supply & fixing.
Gang Single T V Socket Complete, including PVC/steel back Each 24-796 489
box with proper screws, supply & fixing.
Gang Double T V Socket Complete, including PVC/steel back Each 24-797 594
box with proper screws supply & fixing.
Gang Switch 2-pole 20 A, 250 V, Complete, including Each 24-798 672
PVC/steel back box with proper screws supply & fixing.
Same as item 24-792 to 24-799, but fixing only. Each 24-799 104
Add to item 24-792 to 24-790 or 24-799, if removal only. Each 24-800 69
Gang Telephone socket shuttered, including PVC/steel back Each 24-812 594
box with proper screws complete, supply & fixing.
Gang TV socket shuttered, including PVC/steel back box with Each 24-813 560
proper screws complete, supply & fixing.
Gang Twin TV/ Telephone socket shuttered, including Each 24-814 885
PVC/steel back box with proper screws complete, supply &
fixing.
Gang One gang switch + One Socket including PVC/steel back Each 24-815 711
box with proper screws complete, supply & fixing.
Same as item 24-815, but Two gang switch + One Socket Each 24-816 1103
Same as item 24-815, Three gang switch + One Socket Each 24-817 1190
Same as item 24-815, Four gang switch + One Socket Each 24-818 1388
Same as item 24-815, Five gang switch + One Socket Each 24-819 1718
Same as item 24-815, Six gang switch + One Socket Each 24-820 1849
Same as item 24-815, One gang switch + One Dimmer Each 24-821 1234
Same as item 24-815, Two gang switch + One Dimmer Each 24-822 1364
Same as item 24-815, Three gang switch + One Dimmer Each 24-823 1691
Same as item 24-815, Four gang switch + One Dimmer Each 24-824 1867
Same as item 24-815, Six gang switch + One Dimmer Each 24-825 2066
Same as item 24-815, Three gang Switch + one Dimmer + One Each 24-826 2197
Socket
Same as item 24-815, 5 Step Fan speed controller including Each 24-827 1169
PVC / steel back box with proper screws.
Same as item 24-815, Fan speed controller with Switch. Each 24-828 1082
Same as item 24-815, 5 Amp 3 Pin Switch Multi Socket. Each 24-829 690
Same as item 24-815, 10 Amp 3 Pin Switch Socket. Each 24-830 537
Same as item 24-815, 15 Amp 3 Pin Switch Socket. Each 24-831 624
Same as item 24-815, 20 Amp 3 Pin Switch Socket. Each 24-832 650
Same as item 24-812 to 24-832, but fixing only. Each 24-833 173
Add to item 24-812 to 24-832 or 24-833, if removal only. Each 24-834 104
Lawn / Garden light, complete with 23W, LED Bulb, plastic Each 24-835 6945
cover and mounting bracket (without pipe post), supply and
fixing.
Same as item 24-835, but fixing only Each 24-836 345
Add to item 24-835or 24-836, if removal only. Each 24-837 173
Wall Bracket, fancy, single, complete with holder and lamp, Each 24-838 2229
supply and fixing.
Same as item 24-838, but Double. Each 24-839 2709
Porch light, fancy, complete with holder and lamp, supply and Each 24-840 1509
fixing.
Gate light, fancy, complete with holder and lamp of approved Each 24-841 2941
type, supply and fixing.
Same as item 24-840 to 24-841, but fixing only. Each 24-842 69
Add to item 24-840 to 24-841 or 24-842, if removal only. Each 24-843 52
Obstruction light, with Red glass, holder, bracket, lamp and Each 24-844 6213
rod etc complete, supply and fixing.
Same as item 24-844, but fixing only. Each 24-845 345
Add to item 24-844 or 24-845, if removal only. Each 24-846 259
Phase Sequence Relay for electric motor, 3 Phase, 50 Cycles Each 24-847 10590
supply and fixing.
Same as item 24-847 but fixing only. Each 24-848 690
Add to item 24-847 or 24-848 if removal only. Each 24-849 345
Digital Ampere meter 600 A for LT panel, CT Operated supply Each 24-850 7269
& fixing
Analog Ampere meter 600 A for LT panel, CT Operated supply Each 24-851 2469
& fixing
Digital Volt meter 220/440 V for LT panel, CT Operated with Each 24-852 6669
selector switch, supply & fixing
Analog Volt meter 220/440 V for LT panel, CT Operated with Each 24-853 2469
Selector switch, supply & fixing
Same as item 24-850 to 24-853, but fixing only. Each 24-854 69
Add to item 24-850 to 24-853 or 24-854, if removal only. Each 24-855 35
Exit Light LED Complete with steel sheet powder coated, Each 24-856 9208
suitable operation on single phase with lithium battery for 12
hours back up, supply & Fixing.
Same as item 24-856, but fixing only. Each 24-857 80
Add to item 24-856 or 24-857, if removal only. Each 24-858 35
Magnetic Contactor 4 Pole
Magnetic Contactor operational Current 40 to 60 Amps 3 Each 24-859 9143
phase, 4 pole, 440 volts, complete approved type, supply and
fixing
Same as item 24-859 but, 50 to 80 Amps Each 24-860 13432
Same as item 24-859 but, 65 to 100 Amps Each 24-861 17358
Same as item 24-859 but 75 to 110 Amps Each 24-862 21234
Same as item 24-859 but 85 to 135 Amps Each 24-863 22518
Same as item 24-859 but 100 to 150 Amps Each 24-864 37638
Same as item 24-859 but 130 to 150 Amps Each 24-865 44779
Same as item 24-859 but 150 to 200 Amps Each 24-866 53438
Same as item 24-859 but 185 to 230 Amps Each 24-867 57697
Same as item 24-859 but 225 to 260 Amps Each 24-868 68312
Same as item 24-859 but 265 to 300 Amps Each 24-869 109235
Same as item 24-859 to 24-864, but fixing only. Each 24-870 259
Same as item 24-865 to 24-869, but fixing only. Each 24-871 345
Add to item 24-859to 24-864 or 24-870, if removal only. Each 24-872 138
Add to item 24-865 to 24-869 or 24-871, if removal only. Each 24-873 276
Add to item 24-881 to 24-885 or 24-891, if removal only. Each 24-894 207
Add to item 24-886 to 24-889 or 24-892, if removal only. Each 24-895 276
Digging holes, in ordinary soil, provision and erection in Each 25-21 65785
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but round conical, galvanized 10 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-9, 25-10).
Same as item 25-21, but Double Arm (figure 25-8, 25-10). Each 25-22 69385
Digging holes, in ordinary soil, provision and erection in Each 25-23 82945
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but round conical, galvanized, 12 metre
long, including “J” bolt set, single arm pole complete with
base plate as specified (figure 25-9, 25-10).
Same as item 25-23, but Double Arm (figure 25-8, 25-10). Each 25-24 85825
Digging holes, in ordinary soil, provision and erection in Each 25-25 58333
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 9 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).
Same as item 25-25, but Double Arm (figure 25-6, 25-10). Each 25-26 59929
Digging holes, in ordinary soil, provision and erection in Each 25-27 62089
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 10 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).
Same as item 25-27, but Double Arm (figure 25-6, 25-10). Each 25-28 73142
Digging holes, in ordinary soil, provision and erection in Each 25-29 80905
position and setting 150 mm thick PCC 1:2:4 foundation for
Street Light pole but Octagonal, galvanized, 12 metre long,
including “J” bolt set, single arm pole complete with base
plate as specified (figure 25-7, 25-10).
Same as item 25-29, but Double Arm (figure 25-6, 25-10). Each 25-30 83905
Same as item 25-19, 25-25 but fixing only. Each 25-31 6985
Same as item 25-20, 25-26 but fixing only. Each 25-32 6985
Same as item 25-21, 25-27 but fixing only. Each 25-33 6985
Same as item 25-22 or 25-28 but fixing only. Each 25-34 6985
Same as item 25-23 or 25-29 but fixing only. Each 25-35 6985
Same as item 25-24 or 25-30 but fixing only. Each 25-36 6985
Add to item 25-19, 25-25 or 25-31 if removal only. Each 25-37 2079
Add to item 25-20, 25-26 or 25-32 if removal only. Each 25-38 2079
Add to item 25-21, 25-27 or 25-33 if removal only. Each 25-39 2079
Add to item 25-22, 25-28 or 25-34 if removal only. Each 25-40 2079
Add to item 25-23, 25-29 or 25-35 if removal only. Each 25-41 2079
Add to item 25-24, 25-30 or 25-36 if removal only. Each 25-42 2079
“L” Type Lattice Steel Pole
Digging hole, in ordinary soil, provision and erection of "L"- Each 25-43 29697
Type Lattice Steel pole, un-galvanized, including provision of
PCC 1:2:4, all as per WAPDA Drawing No. PDW/DF-10 (figure
25-11).
Same as item 25-43, but galvanized. Each 25-44 35097
Same as item 25-43 or 25-44, but fixing only. Each 25-45 6297
Add to item 25-43, 25-44 or 25-45, if removal only. Each 25-46 2079
Add to item 25-43 to 25-46, if fixed in hard soil. Each 25-47 228
Add to item 25-43 to 25-46, if fixed in rock. Each 25-48 1670
“H” Type Lattice Steel Pole
Digging hole in ordinary soil, provision and erection of "H" Each 25-49 42444
Type Lattice Steel pole, un-galvanized, including provision of
PCC 1:2:4, all as per WAPDA Drawing no. PDW/DF 11 (figure
25-12).
Same as item 25-49, but galvanized. Each 25-50 47244
Same as item 25-49 or 25-50, but fixing only. Each 25-51 8844
Add to item 25-49 to 25-50, 25-51 if removal only. Each 25-52 2079
Add to item 25-49 to 25-51, if fixed in hard soil. Each 25-53 228
Add to item 25-49 to 25-51, if fixed in rock. Each 25-54 1670
Digging hole in ordinary soil, provision and erection of "H" Each 25-55 120756
Type Lattice Steel pole 45 ft, un-galvanized, including
provision of PCC 1:2:4, all as specified.
Same as item 25-55, but galvanized. Each 25-56 136200
Same as item 25-55 or 25-56, but fixing only. Each 25-57 16860
Add to item 25-55 to 25-56, if removal only. Each 25-58 4568
Add to item 25-55 to 25-57, if fixed in hard soil. Each 25-59 270
Add to item 25-55 to 25-57, if fixed in rock. Each 25-60 3000
Cross Arm
Cross arms galvanized channels iron with clamp, washers, Each 25-61 4489
bolts and nuts etc Type "A", supply and fixing (figure 25-15).
Add to item 25-84, 25-85, 25-89 or 25-90, if removal only. Each 25-93 327
Stays
Provision and fixing of stay assembly, stay wire (7/10 SWG), Each 25-94 6508
stay clamps, insulated including setting in earth, with PCC
1:3:6, complete, upto 13.75 M length.
Provision and fixing of stay flying, complete with stay wire Each 25-95 6219
(7/10 SWG), stay assembly, stay clamps, upto 15 M length.
Same as item 25-94, but fixing only. Each 25-96 2668
Same as item 25-94, but fixing only. Each 25-97 2668
Add to item 25-94 to 25-97, if removal only. Each 25-98 1023
Copper Conductor
Stringing, straining, tensioning and binding Copper Metre 25-99 137
conductor, bare solid or stranded 10 SWG, supply and fixing.
Add to item 25-104 to 25-106 or 25-120, if removal only. Metre 25-125 102
Add to item 25-107 to 25-112 or 25-121, if removal only. Metre 25-126 147
Add to item 25-116 to 25-118 or 25-123, if removal only. Metre 25-128 123
Cable Electric aluminium - HT (3 core)
Cable electric HT, 11 KV stranded aluminium conductor, XLPE Metre 25-129 1991
insulated, extruded, PVC bedded, steel wire armoured and
PVC sheathed overall 3 core, 16 mm2, laid in trenches
complete with bricks, sand (excluding cost of excavation),
supply and fixing.
Same as item 25-129, but 25 mm². Metre 25-130 2227
Same as item 25-129, but 35 mm². Metre 25-131 2362
Same as item 25-129, but 50 mm². Metre 25-132 2610
Same as item 25-129, but 70 mm². Metre 25-133 2916
Same as item 25-129, but 95 mm². Metre 25-134 3300
Same as item 25-129, but 120 mm². Metre 25-135 3623
Same as item 25-129, but 150 mm². Metre 25-136 4216
Same as item 25-129, but 185 mm². Metre 25-137 4633
Same as item 25-129, but 240 mm². Metre 25-138 5234
Same as item 25-129, but 300 mm². Metre 25-139 5898
Cable electric HT, 11 KV stranded aluminium conductor XLPE Metre 25-140 1716
insulated, extruded PVC bedded, steel wire armoured and
2
PVC sheathed overall, 3 core 16 mm laid in GI/RCC Pipe/duct
(excluding cost of pipe/duct), supply and fixing.
Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-257 1426
overall PVC 600/1000 V, with stranded copper conductor 16
mm², 4 core laid in trenches complete with bricks, sand
(excluding cost of excavation), supply and fixing.
Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-283 1982
armoured overall PVC 600/1000 V, with stranded copper
conductor, 25 mm², 3½ core, laid in trenches, complete with
bricks, sand (excluding cost of excavation), supply and fixing.
Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-307 1863
overall PVC 600/1000 V, with stranded copper conductor 25
mm², but 3½ core, laid in trenches complete with bricks, sand
(excluding cost of excavation), supply and fixing.
Cable electric LT, 600/1000 V, stranded copper conductor Metre 25-357 597
insulated, extruded, PVC un-armoured and PVC sheathed
2
overall, single core, 16 mm laid in trenches complete with
bricks, sand (excluding cost of excavation) supply and fixing.
Cable electric LT, PVC insulated, PVC sheathed, steel wire Metre 25-383 964
armoured, overall PVC, 600/1000 V with stranded aluminium
conductor, 25 mm2, 4 core, laid in trenches, complete with
bricks, sand (excluding cost of excavation), supply and fixing.
Cable electric LT, PVC insulated, PVC sheathed, un-armoured, Metre 25-407 707
overall, PVC 600/1000 V, with stranded aluminium
conductor, 25 mm², 4 core laid in trenches complete with
bricks, sand (excluding cost of excavation), supply and fixing.
Cable electric LT, 600/1000 V stranded aluminium conductor, Metre 25-457 429
insulated extruded PVC Un-armoured and PVC sheathed
overall single core, 16 mm2 laid in trenches complete with
bricks, sand (excluding cost of excavation) supply and fixing.
Add to item 25-486 to 25-487 or 25-489, if removal only. Each 25-491 414
PVC Straight Joint LT, complete with tapes, ferrules and heat Each 25-492 4732
tubes etc, as specified for PVC armoured, LT Cable 4 core 16
mm², supply and fixing.
Same as item 25-492, but 25 mm² to 35 mm². Each 25-493 8526
Same as item 25-492, but 50 mm² to 70 mm². Each 25-494 10310
Same as item 25-492, but 95 mm² to 150 mm². Each 25-495 13186
Same as item 25-492, but 185 mm² to 300 mm². Each 25-496 17826
Same as item 25-492 to 25-493, but fixing only. Each 25-497 1518
Same as item 25-494, but fixing only. Each 25-498 2277
Same as item 25-495 to 25-496, but fixing only. Each 25-499 3036
Add to item 25-492 to 25-499, if removal only. Each 25-500 414
PVC, T-Service Joint LT, comprising mould resin, padding Each 25-501 6899
tape, funnels and ferrules etc, as specified for LT cable, 4
core, 16 mm2, supply and fixing.
Same as item 25-501, but 25 mm² to 50 mm² x 16 mm² to 25 Each 25-502 8764
mm².
Same as item 25-501, but 70 mm2 to 95 mm² x 35 to 50 Each 25-503 11877
mm².
Same as item 25-501, but 120 mm2 to 185 mm² x 70 mm2 to Each 25-504 22913
95 mm².
Same as item 25-501, but fixing only. Each 25-505 1822
Same as item 25-502, but fixing only. Each 25-506 2277
Same as item 25-503, but fixing only. Each 25-507 3036
Same as item 25-504, but fixing only. Each 25-508 3795
Add to item 25-501 to 25-508, if removal only. Each 25-509 276
PVC Heat Shrink (HS) Termination Kit, LT indoor / outdoor, Each 25-510 6022
consisting of heat shrink, boot lugs, clips and earth wire etc,
suitable for LT cables, 4 core, 16 mm2, PVC un-armoured,
supply and fixing.
Same as item 25-510, but 25 mm2 to 35 mm². Each 25-511 6325
2 Each 25-512 8277
Same as item 25-510, but 50 mm to 70 mm2.
Same as item 25-510, but 95 mm2 to 150 mm². Each 25-513 10229
2 Each 25-514 12075
Same as item 25-510, but 185 mm to 300 mm².
Same as item 25-510, but fixing only. Each 25-515 1822
Same as item 25-511, but fixing only. Each 25-516 2125
Same as item 25-512, but fixing only. Each 25-517 2277
Same as item 25-513, but fixing only. Each 25-518 2429
Same as item 25-514, but fixing only. Each 25-519 3795
Add to item 25-510 to 25-519, if removal only. Each 25-520 414
PVC Heat Shrink (HS) Termination kit LT, 4 core, Each 25-521 6562
indoor/outdoor, consisting of heat shrink boot, lugs, clips and
earth wire etc suitable for LT Cable, armoured, 16 mm²,
supply and fixing.
2 Each 25-522 7885
Same as item 25-521, but 25 mm to 35 mm².
Same as item 25-521, but 50 mm² to 70 mm². Each 25-523 10077
Same as item 25-521, but 95 mm2 to 150 mm². Each 25-524 11249
Same as item 25-521, but 185 mm2 to 300 mm². Each 25-525 13995
Same as item 25-521, but fixing only. Each 25-526 1822
Same as item 25-522, but fixing only. Each 25-527 2125
Same as item 25-523, but fixing only. Each 25-528 2277
Same as item 25-524, but fixing only. Each 25-529 2429
Same as item 25-525, but fixing only. Each 25-530 3795
Add to item 25-521 to 25-530, if removal only. Each 25-531 414
PVC Termination kit, HT 11 KV, indoor heat shrink, complete Each 25-532 13474
with tubes, copper Lugs, HT and PIB tapes and earth wire,
suitable for HT cables, XLPE, 3 core, 16 mm2 to 35 mm²,
supply and fixing.
Same as item 25-532, but for HT cable XLPE, 3 core, 50 to 95 Each 25-533 15492
mm².
Same as item 25-532, but for HT cable XLPE, 3 core, 120 Each 25-534 20664
to185 mm².
Same as item 25-532, but for HT cable XLPE, 3 core, 240 to Each 25-535 22910
300 mm².
PVC Termination kit, HT, 11 KV outdoor, heat shrink, Each 25-536 13474
complete with tubes, copper lugs, HT and PIB tapes and earth
wire suitable for HT cable, XLPE, 3 core, 16 mm² to 35 mm²,
supply and fixing.
Same as item 25-536 but 50 mm² to 95 mm². Each 25-537 15492
Same as item 25-536 but 120 mm² to 185 mm². Each 25-538 20664
Same as item 25-536 but 240 mm² to 300 mm². Each 25-539 22910
Same as item 25-532 or 25-536, but fixing only. Each 25-540 3274
Same as item 25-533 or 25-237, but fixing only. Each 25-541 4092
Same as item 25-534 or 25-538, but fixing only. Each 25-542 4464
Same as item 25-535 or 25-539, but fixing only. Each 25-543 4910
Add to item 25-532 to 25-543, if removal only. Each 25-544 414
PVC, Straight joint, HT, 11 KV for XLPE cable, consisting of Each 25-545 22474
mould resin, HT tape, semi conducting tape, ferrules and
earth wire etc suitable for HT cables, 3 core, 16 mm² to 35
mm², supply and fixing.
Same as item 25-545, but for HT cable XLPE, 3 core, 50 mm² Each 25-546 28092
to 95 mm².
Same as item 25-545, but for HT cable XLPE, 120 mm² to 185 Each 25-547 34310
mm².
Same as item 25-545, but for HT cable XLPE, 240 mm² to 300 Each 25-548 38595
mm².
Same as item 25-545, but fixing only. Each 25-549 3274
Same as item 25-546, but fixing only. Each 25-550 4092
Same as item 25-547, but fixing only. Each 25-551 4910
Same as item 25-548, but fixing only. Each 25-552 5115
Add to item 25-545 to 25-552, if removal only. Each 25-553 558
PVC, Straight joint Single core
PVC, Straight joint LT, consisting of mould resin, padding Each 25-554 1094
tape, funnels and ferrules etc as specified for PVC
unarmoured LT cable, Single core, 16 mm², supply and fixing.
Add to item 25-557 to 25-558 or 25-560, if removal only. Each 25-562 207
PVC Straight Joint LT, complete with tapes, ferrules and heat Each 25-563 1411
tubes etc, as specified for PVC armoured LT cable, Single
core, 16 mm², supply and fixing.
Same as item 25-563, but 25 mm² to 35 mm². Each 25-564 2241
Same as item 25-563, but 50 mm² to 70 mm². Each 25-565 3135
Same as item 25-563, but 95 mm² to 150 mm². Each 25-566 4023
Same as item 25-563, but 185 mm² to 300 mm². Each 25-567 6487
Same as item 25-563 to 25-564, but fixing only. Each 25-568 380
Same as item 25-565, but fixing only. Each 25-569 759
Same as item 25-566 to 25-567, but fixing only. Each 25-570 759
Add to item 25-563 to 25-570, if removal only. Each 25-571 518
PVC, T-Service Joint, LT comprising mould resin, padding Each 25-572 2137
tape, funnels and ferrules etc, as specified for LT cable, Single
core, 16 mm2, supply and fixing.
Same as item 25-572, but 25 mm² to 50 mm² x 16 mm² to 25 Each 25-573 2236
mm².
Same as item 25-572, but 70 mm2 to 95 mm² x 35 to 50 Each 25-574 3128
mm².
Same as item 25-572, but 120 mm2 to 185 mm² x 70 mm2 to Each 25-575 5856
95 mm².
Same as item 25-572, but fixing only. Each 25-576 455
Same as item 25-573, but fixing only. Each 25-577 569
Same as item 25-574, but fixing only. Each 25-578 759
Same as item 25-575, but fixing only. Each 25-579 949
Add to item 25-572 to 25-579, if removal only. Each 25-580 138
PVC Heat Shrink (HS) Termination Kit, LT indoor/outdoor, Each 25-581 1323
consisting of heat shrink, boot lugs, clips and earth wire etc,
suitable for LT cables, Single core, 16 mm2 PVC un-armoured,
supply and fixing.
Same as item 25-581, but 25 mm2 to 35 mm². Each 25-582 2215
2 Each 25-583 2762
Same as item 25-581, but 50 mm to 70 mm².
2 Each 25-584 4340
Same as item 25-581, but 95 mm to 150 mm².
2 Each 25-585 6515
Same as item 25-581, but 185 mm to 300 mm².
Same as item 25-581, but fixing only. Each 25-586 455
Same as item 25-582, but fixing only. Each 25-587 531
Same as item 25-583, but fixing only. Each 25-588 569
Same as item 25-584, but fixing only. Each 25-589 607
Same as item 25-585, but fixing only. Each 25-590 949
Add to item 25-581 to 25-590, if removal only. Each 25-591 207
PVC Heat Shrink (HS) Termination kit LT, indoor/outdoor, Each 25-592 1530
consisting of heat shrink, boot, lugs, clips and earth wire etc
suitable for LT cable, armoured, 16 mm², Single core supply
and fixing.
Same as item 25-592, but 25 mm2 to 35 mm². Each 25-593 2623
Same as item 25-592, but 50 mm² to 70 mm². Each 25-594 3375
Same as item 25-592, but 95 mm2 to 150 mm². Each 25-595 3821
2 Each 25-596 5631
Same as item 25-592, but 185 mm to 300 mm².
Same as item 25-592, but fixing only. Each 25-597 449
Same as item 25-593, but fixing only. Each 25-598 531
Same as item 25-594, but fixing only. Each 25-599 569
Same as item 25-595, but fixing only. Each 25-600 607
Same as item 25-596, but fixing only. Each 25-601 949
Add to item 25-592 to 25-601, if removal only. Each 25-602 207
PVC Termination kit, HT, 11 KV, indoor heat shrink, complete Each 25-603 7557
with tubes, copper Lugs, HT and PIB tapes and earth wire,
2
suitable for HT cables, XLPE, Single core, 16 mm to 35 mm²,
supply and fixing.
Same as item 25-603, but 50 to 95 mm². Each 25-604 8840
Same as item 25-603, but 120 to185 mm². Each 25-605 9680
Same as item 25-603, 3 core, 240 to 300 mm². Each 25-606 11111
PVC Termination kit, HT, 11 KV outdoor, heat shrink, Each 25-607 8125
complete with tubes, copper lugs, HT and PIB tapes and earth
wire suitable for HT cable, XLPE, Single core, 16 mm² to 35
mm², supply and fixing.
Same as item 25-607, but 50 mm² to 95 mm². Each 25-608 11773
Same as item 25-607, but 120 mm² to 185 mm². Each 25-609 13652
Same as item 25-607, but 240 mm² to 300 mm². Each 25-610 14792
Same as item 25-603, or 25-607 but fixing only. Each 25-611 1362
Same as item 25-604, or 25-608 but fixing only. Each 25-612 1362
Same as item 25-605, or 25-609 but fixing only. Each 25-613 1637
Same as item 25-606, or 25-610 but fixing only. Each 25-614 1702
Add to item 25-603 to 25-614, if removal only. Each 25-615 279
PVC Straight joint, HT, 11 KV for XLPE cable, consisting of Each 25-616 11392
mould resin, HT tape, semi conducting tape, ferrules and
earth wire etc suitable for HT cables, single core, 16 mm² to
35 mm², supply and fixing.
Same as item 25-616, but for HT cable XLPE, 50 mm² to 95 Each 25-617 12268
mm².
Same as item 25-616, but for HT cable XLPE, 120 mm² to 185 Each 25-618 15295
mm².
Same as item 25-616, but for HT cable XLPE, 240 mm² to 300 Each 25-619 17616
mm².
Same as item 25-616, but fixing only. Each 25-620 1088
Same as item 25-617, but fixing only. Each 25-621 1362
Same as item 25-618, but fixing only. Each 25-622 1637
Same as item 25-619, but fixing only. Each 25-623 1702
Add to item 25-616 to 25-623, if removal only. Each 25-624 279
Danger sign, for HT and LT, not less than 250 mm x 125 mm Each 25-625 736
size, enamelled as required, supply and fixing.
Same as item 25-625, but fixing only. Each 25-626 256
Add to item 25-625 or 25-626, if removal only. Each 25-627 179
Non Climbable Device, as specified, (Figure 25-13), supply Each 25-628 1525
and fixing.
Same as item 25-628, but fixing only. Each 25-629 409
Add to item 25-628 or 25-629, if removal only. Each 25-630 304
Phase Indicating sign, red, blue or yellow as required, supply Each 25-631 529
and fixing.
Same as item 25-631, but fixing only. Each 25-632 49
Add to item 25-631 or 25-632, if removal only. Each 25-633 49
GI clamp for shackle, insulator or stay wire etc, of approved Each 25-634 308
type, supply and fixing.
Same as item 25-634, but fixing only. Each 25-635 123
Add to item 25-634 or 25-635, if removal only. Each 25-636 91
Lightning Arrester set of three pieces, complete, with all Each 25-637 17286
accessories, for 11 KV line, supply and fixing.
Same as item 25-637, but fixing only. Each 25-638 2046
Add to item 25-637 or 25-638, if removal only. Each 25-639 1432
Fuse D-link/cut off fuses assembly, set of three, complete Each 25-640 19838
with fuse, angle iron, nut and bolt, etc for 11 KV (assembly
unit), supply and fixing.
Same as item 25-640, but fixing only. Each 25-641 4092
Add to item 25-640 or 25-641, if removal only. Each 25-642 2864
Service Connection, complete with PVC insulated and PVC Metre 25-643 239
sheathed cable, 250 V, twin core, run on GI wire No 8 SWG
with brass/iron tinned clips of appropriate size at 20 cm
interval, size 2.5 mm², supply and fixing.
Same as item 25-643, but size, 4 mm². Metre 25-644 323
Same as item 25-643 or 25-644, but fixing only. Metre 25-645 61
Add to item 25-643 to 25-645, if removal only. Metre 25-646 43
Service Connection, complete with PVC insulated and PVC Metre 25-647 399
sheathed, 4 cores copper conductor, cable 2.5 mm², run on
No 8 SWG GI wire with brass/iron tinned clips of appropriate
size, at 10 cm interval, supply and fixing.
Same as item 25-647, but 4 mm², 4 core cable. Metre 25-648 545
Same as item 25-647 or 25-648, but fixing only. Metre 25-649 82
Add to item 25-647 to 25-649, if removal only. Metre 25-650 57
Service Bracket, comprising 50 mm dia tubing, GI/MS, upto Each 25-651 9645
4.50 M long with 900 bends, 2 nos, with hard wood bushes at
both ends, necessary clamps, bolts etc, without cross arms,
supply and fixing.
Same as item 25-651, but 6 M long. Each 25-652 11280
Same as item 25-651, but fixing only. Each 25-653 3069
Same as item 25-652, but fixing only. Each 25-654 3274
Add to item 25-651 or 25-653, if removal only. Each 25-655 2277
Add to item 25-652 or 25-654, if removal only. Each 25-656 2429
Stay Wire 3/10 SWG or 7/16 SWG upto 7 metre in length, Each 25-657 2647
complete with clamp and anchor bolts for service bracket,
supply and fixing.
Same as item 25-657, but above 7 metre and upto 10 M. Each 25-658 3584
Same as item 25-657 or 25-658, but fixing only. Each 25-659 409
Add to item 25-657 to 25-659, if removal only. Each 25-660 286
Steel Box (16 BG) for main switch, distribution board and Each 25-661 8365
meter, Type A, as per drawing in Figure 25-14, duly painted
with primer and two coats of synthetic enamel paint, supply
and fixing.
Same as item 25-662, but Type B Each 25-662 4404
Same as item 25-662 to 25-663, but fixing only. Each 25-663 174
Add to item 25-662 to 25-664, if removal only. Each 25-664 122
Fuse Aerial Porcelain up to 30 A, supply and fixing. Each 25-665 538
Same as item 25-665, but 60 A. Each 25-666 564
Same as item 25-665 or 25-667, but fixing only. Each 25-667 205
Add to item 25-665 to 25-667, if removal only. Each 25-668 143
Box guard MS, 10 SWG, supply and fixing. Each 25-669 281
Same as item 25-669, but 8 SWG. Each 25-670 302
Same as item 25-669, but 6 SWG. Each 25-671 359
Same as item 25-669 to 25-671, but fixing only. Each 25-672 123
Add to item 25-669 to 25-672, if removal only. Each 25-673 86
Cradle guard, 8 SWG for HT, supply and fixing. Each 25-674 192
Same as item 25-674, but fixing only. Each 25-675 102
Add to item 25-674 or 25-675, if removal only. Each 25-676 72
Cable marker, supply and fixing. Each 25-677 1456
Same as item 25-677, but fixing only. Each 25-678 256
Add to item 25-677 or 25-678, if removal only. Each 25-679 179
Jumpring, 8 SWG copper conductor, supply and fixing. Each 25-680 340
Same as item 25-680, but 6 SWG. Each 25-681 466
Same as item 25-680, but 4 SWG. Each 25-682 583
Same as item 25-680, but 2 SWG. Each 25-683 779
Same as item 25-680, but 1 SWG. Each 25-684 916
Same as item 25-680, but 1/0 SWG. Each 25-685 1060
Same as item 25-680, but 2/0 SWG. Each 25-686 1172
Same as item 25-680, but 3/0 SWG. Each 25-687 1424
Same as item 25-680, but 4/0 SWG. Each 25-688 1523
Same as item 25-680, but 70 mm². Each 25-689 1390
Same as item 25-680, but 95 mm². Each 25-690 1918
Same as item 25-680, but 120 mm². Each 25-691 2357
Same as item 25-680, but 150 mm². Each 25-692 2992
Same as item 25-680 to 25-682, but fixing only. Each 25-693 205
Same as item 25-683 to 25-686, but fixing only. Each 25-694 348
Same as item 25-687 to 25-689, but fixing only. Each 25-695 409
Same as item 25-690, but fixing only. Each 25-696 512
Same as item 25-691, but fixing only. Each 25-697 614
Same as item 25-692, but fixing only. Each 25-698 819
Add to item 25-680 to 25-692 or 25-693 to 25-698, if removal Each 25-699 164
only.
Power Transformer
Supply and erection in position on steel / PCC platform and Each 25-700 286332
connecting up, including testing and commissioning Power
Transformer, step down 11000/400/230 V, 3 phase 50 cycles
indoor/outdoor, 25 KVA Type “A” (excluding cost of
platform).
Same as item 25-700, but 25 KVA Type “B”. Each 25-701 256812
Same as item 25-700, but 25 KVA Type “C”. Each 25-702 193632
Same as item 25-700, but 50 KVA, Type “A”. Each 25-703 436092
Same as item 25-700, but 50 KVA Type “B”. Each 25-704 355092
Same as item 25-700, but 50 KVA Type “C”. Each 25-705 284892
Same as item 25-700, but 100 KVA, Type “A”. Each 25-706 623292
Same as item 25-700, but 100 KVA Type “B”. Each 25-707 523572
Same as item 25-700, but 100 KVA Type “C”. Each 25-708 466092
Same as item 25-700, but 150 KVA, Type “A”. Each 25-709 838458
Same as item 25-700, but 150 KVA Type “B”. Each 25-710 673038
Same as item 25-700, but 150 KVA Type “C”. Each 25-711 567738
Same as item 25-700, but 200 KVA, Type “A”. Each 25-712 1051578
Same as item 25-700, but 200 KVA Type “B”. Each 25-713 799398
Same as item 25-700, but 200 KVA Type “C”. Each 25-714 680058
Same as item 25-700, but 250 KVA, Type “A”. Each 25-715 1264887
Same as item 25-700, but 250 KVA Type “B”. Each 25-716 865647
Same as item 25-700, but 250 KVA Type “C”. Each 25-717 781408
Same as item 25-700, but 300 KVA Type “A”. Each 25-718 1478196
Same as item 25-700, but 300 KVA Type “B”. Each 25-719 917856
Same as item 25-700, but 300 KVA Type “C”. Each 25-720 889776
Same as item 25-700, but 400 KVA, Type “A”. Each 25-721 1898676
Same as item 25-700, but 400 KVA Type “B”. Each 25-722 1374156
Same as item 25-700, but 400 KVA Type “C”. Each 25-723 1320276
Same as item 25-700, but 500 KVA, Type “A”. Each 25-724 2224788
Same as item 25-700, but 500 KVA Type “B”. Each 25-725 1544748
Same as item 25-700, but 500 KVA Type “C”. Each 25-726 1478388
Same as item 25-700, but 630 KVA, Type “A”. Each 25-727 2550900
Same as item 25-700, but 630 KVA Type “B”. Each 25-728 1673220
Same as item 25-700, but 630 KVA Type “C”. Each 25-729 1560900
Same as item 25-700, but 1000 KVA, Type “A”. Each 25-730 3040500
Same as item 25-700, but 1000 KVA Type “B”. Each 25-731 2059332
Same as item 25-700, but 1000 KVA Type “C”. Each 25-732 1930500
Same as item 25-700 to 25-702, but fixing only. Each 25-733 4092
Same as item 25-703 to 25-705, but fixing only. Each 25-734 4092
Same as item 25-706 to 25-708, but fixing only. Each 25-735 4092
Same as item 25-709 to 25-711, but fixing only. Each 25-736 6138
Same as item 25-712 to 25-714, but fixing only. Each 25-737 6138
Same as item 25-715 to 25-717, but fixing only. Each 25-738 9207
Same as item 25-718 to 25-720, but fixing only. Each 25-739 12276
Same as item 25-721 to 25-723, but fixing only. Each 25-740 12276
Same as item 25-724 to 25-726, but fixing only. Each 25-741 14433
Same as item 25-727 to 25-729, but fixing only. Each 25-742 16500
Same as item 25-730 to 25-732, but fixing only. Each 25-743 16500
Add to item 25-700 to 25-708 or 25-733 to 25-735 if removal Each 25-744 4092
only.
Add to item 25-709 to 25-714 or 25-736 to 25-737, if removal Each 25-745 6138
only.
Add to item 25-715 to 25-717 or 25-738, if removal only. Each 25-746 9207
Add to item 25-718 to 25-723 or 25-739 to 25-740, if removal Each 25-747 12276
only.
Add to item 25-724 to 25-726 or 25-741, if removal only. Each 25-748 16500
Add to item 25-727 to 25-732 or 25-742 to 25-743, if removal Each 25-749 16500
only.
Power Transformers – Pad Mounted
Supply, fixing, testing and commissioning of Power Each 25-750 831570
Transformer pad mounted type, oil immersed, naturally
cooled, step down 11000/400/230 volts 50 cycles, comprising
with High/Low Voltage compartments and controls, 25 KVA,
Type “A” (excluding pad), supply and fixing.
Same as item 25-750, but 25 KVA Type “B”. Each 25-751 408444
Same as item 25-750, but 25 KVA Type “C”. Each 25-752 322092
Same as item 25-728, but 50 KVA, Type “A”. Each 25-753 998332
Same as item 25-750, but 50 KVA Type “B”. Each 25-754 572712
Same as item 25-750, but 50 KVA Type “C”. Each 25-755 468492
Same as item 25-728, but 100 KVA, Type “A”. Each 25-756 1165650
Same as item 25-750, but 100 KVA Type “B”. Each 25-757 902652
Same as item 25-750, but 100 KVA Type “C”. Each 25-758 695292
Same as item 25-728, but 150 KVA, Type “A”. Each 25-759 1400695
Same as item 25-750, but 150 KVA Type “B”. Each 25-760 1057092
Same as item 25-750, but 150 KVA Type “C”. Each 25-761 1027608
Same as item 25-728, but 200 KVA, Type “A”. Each 25-762 1735334
Same as item 25-750, but 200 KVA Type “B”. Each 25-763 1269738
Same as item 25-750, but 200 KVA Type “C”. Each 25-764 1255698
Same as item 25-728, but 250 KVA, Type “A”. Each 25-765 2124492
Same as item 25-750, but 250 KVA Type “B”. Each 25-766 1353978
Same as item 25-750, but 250 KVA Type “C”. Each 25-767 1190538
Same as item 25-728, but 300 KVA, Type “A”. Each 25-768 2322150
Same as item 25-750, but 300 KVA Type “B”. Each 25-769 1437336
Same as item 25-750, but 300 KVA Type “C”. Each 25-770 1314276
Same as item 25-728, but 400 KVA, Type “A”. Each 25-771 2707048
Same as item 25-750, but 400 KVA Type “B”. Each 25-772 2048076
Same as item 25-750, but 400 KVA Type “C”. Each 25-773 1734276
Same as item 25-728 but 500 KVA, Type “A”. Each 25-774 3298907
Same as item 25-750, but 500 KVA Type “B”. Each 25-775 2415228
Same as item 25-750, but 500 KVA Type “C”. Each 25-776 1904388
Same as item 25-728, but 630 KVA, Type “A”. Each 25-777 3733461
Same as item 25-750, but 630 KVA Type “B”. Each 25-778 2613900
Same as item 25-750, but 630 KVA Type “C”. Each 25-779 2114100
Same as item 25-728, but 1000 KVA, Type “A”. Each 25-780 4523818
Same as item 25-750, but 1000 KVA Type “B”. Each 25-781 3173388
Same as item 25-750, but 1000 KVA Type “C”. Each 25-782 2892588
Same as item 25-750 to 25-752, but fixing only. Each 25-783 4092
Same as item 25-753 to 25-755,, but fixing only. Each 25-784 4092
Same as item 25-756 to 25-758, but fixing only. Each 25-785 4092
Same as item 25-759 to 25-761, but fixing only. Each 25-786 4092
Same as item 25-762 to 25-764, but fixing only. Each 25-787 6138
Same as item 25-765 to 25-767, but fixing only. Each 25-788 12276
Same as item 25-768 to 25-770, but fixing only. Each 25-789 12276
Same as item 25-771 to 25-773, but fixing only. Each 25-790 12276
Same as item 25-774 to 25-776, but fixing only. Each 25-791 14388
Same as item 25-777 to 25-779, but fixing only. Each 25-792 16350
Same as item 25-780 to 25-782, but fixing only. Each 25-793 16350
Add to item 25-750 to 25-761 or 25-783 to 25-786, if removal Each 25-794 3069
only.
Add to item 25-762 to 25-767 or 25-787 to 25-788, if removal Each 25-795 4092
only.
Add to item 25-768 to 25-770 or 25-789, if removal only. Each 25-796 9207
Add to item 25-771 to 25-773, or 25-790, if removal only. Each 25-797 9207
Add to item 25-774 to 25-776, or 25-791, if removal only. Each 25-798 10791
Same as Item 25-800 but capacity 200 KVA. Each 25-801 3414138
Same as Item 25-800 but capacity 400 KVA. Each 25-802 4488276
Same as Item 25-800 but capacity 500 KVA. Each 25-803 4814388
Same as Item 25-800 but capacity 630 KVA. Each 25-804 4934338
Same as Item 25-800 but capacity 800 KVA. Each 25-805 5222388
Same as Item 25-800 but capacity 1000 KVA. Each 25-806 6722388
DRY TYPE TRANSFORMER INSULATION CLASS "F" Aluminium
WINDING
Supply, erection, Installation, Testing and Commissioning of Each 25-807 2380092
Dry type indoor, power transformer having continuous rating
of 11000/400/230 volt, 3 phase, 50 HZ, having off load tap
changing arrangement on high voltage side. The taping to be
provided for variation of high voltage from -10% to +5% in
seven step of 2.5% each, for "F" Class insulation, Aluminium
winding Capacity 100 KVA.
Same as Item 25-807 but capacity 200 KVA. Each 25-808 2574138
Same as Item 25-807 but capacity 400 KVA. Each 25-809 2928276
Same as Item 25-807 but capacity 500 KVA. Each 25-810 3374388
Same as Item 25-807 but capacity 630 KVA. Each 25-811 3746388
Same as Item 25-807 but capacity 800 KVA. Each 25-812 4070388
Same as Item 25-807 but capacity 1000 KVA. Each 25-813 4238388
Same as Item 25-800 to 25-807 but fixing only. Each 25-814 4092
Same as Item 25-801 or 25-808 but fixing only. Each 25-815 6138
Same as Item 25-802 or 25-809 but fixing only. Each 25-816 12276
Same as Item 25-803 or 25-810 but fixing only. Each 25-817 14388
Same as Item 25-804 or 25-811 but fixing only. Each 25-818 16500
Same as Item 25-805 or 25-812 but fixing only. Each 25-819 16500
Same as Item 25-806 or 25-813 but fixing only. Each 25-820 16500
Add to item 25-800, 25-807 or 25-814 if removal only. Each 25-821 3039
Add to item 25-801, 25-808 or 25-815 if removal only. Each 25-822 4603
Add to item 25-802, 25-809 or 25-816 if removal only. Each 25-823 6138
Add to item 25-803, 25-810 or 25-817 if removal only. Each 25-824 10791
Add to item 25-804, 25-811 or 25-818 if removal only. Each 25-825 10791
Add to item 25-805, 25-812 or 25-819 if removal only. Each 25-826 10791
Add to item 25-806, 25-813 or 25-820 if removal only. Each 25-827 10791
Transformer Single Phase
Supply, fixing and erection in position on steel/PCC platform Each 25-828 244092
and connecting up, including testing and commissioning
Power Transformer, step down 11000/230 V, single phase,
50 cycles, indoor/outdoor, 25 KVA (excluding cost of
platform).
Same as item 25-828, but 50 KVA. Each 25-829 334092
Same as item 25-828, but 100 KVA. Each 25-830 502092
Same as item 25-828, but fixing only. Each 25-831 4092
Same as item 25-829, but fixing only. Each 25-832 4092
Same as item 25-830, but fixing only. Each 25-833 4092
Add to item 25-828 to 25-833 if removal only. Each 25-834 4092
Potential Transformer
Potential Transformer (PT), 11000 / 230 V or 110 V, for HT Each 25-835 73023
panel, supply and fixing.
Same as item 25-835, but fixing only. Each 25-836 1023
Add to item 25-835 or 25-836, if removal only. Each 25-837 716
HT / LT Current Transformers (CT)
Current Transformer (CT), Ratio 25/5, 35/5 or 75/5 A, for HT Each 25-838 57471
panel, supply and fixing.
Same as item 25-838, but CT Ratio 100/5 A Each 25-839 49983
Same as item 25-838, but CT Ratio 25/5 A for LT panel. Each 25-840 2432
Same as item 25-838 but CT Ratio 35/5 A to 1000/5 A, for LT Each 25-841 5792
panel.
Same as item 25-838 to 25-839, but fixing only Each 25-842 1023
Same as item 25-840 to 25-841, but fixing only. Each 25-843 512
Add to item 25-838 to 25-843, if removal only. Each 25-844 512
LT Switch Board with MCCB
LT Switch Board with 1250 A, MCCB, incoming switch, Each 25-845 612883
complete with thermal over current release, adjustable
magnetic short circuit release, shunt trip coil, CT ratio
1000/5, volt meter and Amp-meter with selector switches,
earth fault relays, complete with TP, neutral common bus
bar, including upto 06 outgoing with neutral link, 3-Phase
MCCB switches, switch board steel sheet factory wired,
painted and installed, complete including making connection,
supply and fixing.
Same as item 25-845, but 1000 A, upto 05 outgoings. Each 25-846 570307
Same as item 25-845, but 800 A, upto 04 outgoing. Each 25-847 457486
Same as item 25-845, but 600 A, upto 04 outgoing. Each 25-848 371889
Same as item 25-845, but 400 A, upto 03 outgoing. Each 25-849 276448
Same as item 25-845 to 25-848, but fixing only. Each 25-850 6204
Same as item 25-849, but fixing only. Each 25-851 4653
Add to item 25-845 to 25-851, if removal only. Each 25-852 3069
LT Panel without MCCB
LT Panel without MCCB, ACB etc complete with digital Each 25-853 29943
Ampere, volts meters, Selector switches, Indication lamps, 3 x
current transformers, cable Gland, copper bus bar, 3 phase
and neutral link, including proper nuts and bolts with spring
washers mounted on proper insulator, Electrical interlocking,
steel sheet powder coated 3 mm thick, switch for operation
on 3 phase, 4 wire, 50 cycles 400-600 volts, 100 Amps.
Supply & Fixing.
Add to item 25-855 to 25-857 or 25-862 if removal only. Each 25-865 2291
Voltage Regulator
Auto Voltage Regulator (AVR), AC 380-400/220-230 V, 3 Each 25-867 1960486
phase,
50 cycles, suitable for un-balanced load, capable of delivering
steady output voltage upto variation of + 1%, complete with
voltmeter and selection switch, pilot lamps and
potentiometer, capacity 30 KVA with upto + 20% variation on
input voltage, (EU Origin ), supply and fixing.
Add to item 25-869 to 25-871 or 25-875 if removal only. Each 25-878 2292
Add to item 25-872 to 25-873 or 25-876 if removal only. Each 25-879 3948
Voltage Regulator
Auto Voltage Regulator (AVR) Servo Control Type, Input 3 Each 25-880 226174
Phase + neutral 380 VAC, Input voltage range ±25% (from
285 V, AC~475 VAC), output voltage, 3 phase, 380 V, AC, rms
stabilized, output voltage accuracy ±1~2%, frequency
50/60 Hz, 5% admitted load variation 0-100%, admitted load
unbalance upto 100%, correction speed 12ms/v, wave form
distortion, <1%, max failure range, <±1%, efficiency, >98%,
cooling, air cooled with fan, operating temperature -10ºC to
+60ºC, relative humidity not more than 90%, storage
temperature -20ºC to +60ºC, over load 200% for 02 Sec,
distortion less than 01%, power factor 0.8, Instrumentation
input & output complete with volt and amp meters with
selection switches, suitable rated input / output terminal
blocks / busbars, all standard protections at input & output
MCCBs (Eu Brand), paint colour light Grey (RAL 7035),
capacity 10 KVA, (Pak Made ), Supply and Fixing.
Add to item 25-883 to 25-885 or 25-892 if removal only. Each 25-896 1432
Add to item 25-886 to 25-888 or 25-893 if removal only. Each 25-897 2292
Add to item 25-889 to 25-890 or 25-894 if removal only. Each 25-898 3948
Same as item 25-902 to 25-904, but fixing only. Each 25-905 7620
Add to item 25-902 to 25-905, if removal only. Each 25-906 930
VCBs
Vacuum Circuit Breaker (VCB), HT 11 KV, panel floor Each 25-907 1697208
mounting, 400/630 A, rating 25 KA, 17.5 KV complete with
selector switches, indicating lamps, spring Charging motor
220 V AC, 50ms DC closing coil 110 V DC, 50ms DC Trip Coil
110 V, CT, PT, Earth fault, over current, short circuit, current
digital relay, frequency meter, amp meter, volt meter,
capacitor trip unit, MCB 06 A, SP, charging handle, push
button, mounted in sheet steel cubicle, factory assembled
duly painted, single panel unit complete with energy meter,
MDI & KVARH complete in all respect.
Same as item 25-907 but one incoming and two outgoing (set Each 25-908 5066808
of three).
Same as item 25-907, but two incoming and one outgoing Each 25-909 5066808
(set of three) including all protections and arrangement for
incoming supply sources and locking device system, electrical
and mechanical interlocking as per manufacturer's
specifications.
Same as item 25-907 to 25-909, but fixing only. Each 25-910 12408
Add to item 25-907 to 25-909 or 25-910, if removal only. Each 25-911 5729
KWH + MDI and KVARH combined meter HT Panel, supply Each 25-912 72060
and fixing.
Same as item 25-912 but fixing only. Each 25-913 1860
Add to item 25-912 or 25-913 if removal only. Each 25-914 1395
Feeder Pillar Cabin, size 600 x 450 x 900 mm, made of steel Each 25-915 57204
sheet (14 BG) and angle iron frame size 38 x 38 mm, with
water resistance, hinged cover having locking arrangement,
duly painted of approved quality, consisting of hard drawn
insulated copper bus-bars 4 nos, capacity 800 -1000 A,
mounted on good quality porcelain base/cleats with brass nut
/ bolts off sizes, drilled holes of appropriate size for inlets and
outlets cables, earthing jointing system, foundation of PCC
1:2:4 and suitable arrangement for breakers incoming and
out-going, (excluding cost of breaker) , supply and fixing.
PG Clamp
PG Clamp 25 mm size, Aluminium with proper GI nuts, bolts Each 25-920 183
and spring washer, Supply & Fixing.
Same as Item 25-920, but 50 mm. Each 25-921 247
Same as Item 25-921, but 75 mm. Each 25-922 531
PG Clamp 25 mm size Bimetal copper/Aluminium for jointing Each 25-923 987
of copper cable with Aluminium conductor or Aluminium
cable with copper, conductor of proper GI nuts, bolts and
spring washer, Supply & Fixing.
Same as Item 25-923 but 50 mm. Each 25-924 1280
Same as Item 25-923 but 75 mm. Each 25-925 1933
Same as Item 25-920 or 25-923 but fixing. Each 25-926 86
Same as Item 25-921 to 25-924 but fixing. Each 25-927 104
Same as Item 25-922 or 25-925 but fixing. Each 25-928 121
Add to item 25-920 to 25-928 if removal only. Each 25-929 86
Bus Tie Ducts
Bus Tie Ducts Copper, 1000 A, TP & N Made out of 14 SWG Metre 25-930 44414
M.S Sheet Steel painted with electro static powder coated
paint RAL-7032 Complete in all respect, supply and fixing.
Add to item 25-934 to 25-935 or 25-937 if removal only. Metre 25-939 512
ATS Panels
ATS Panel 10 KVA, ATP & N, Made out of 14 SWG M.S Sheet Each 25-940 96748
Steel painted with electro static powder coated (paint RAL-
7032ATS), Panel Complete in all respect. Supply & Fixing.
Same as item 25-940 but 15 KVA, ATS Panels. Each 25-941 100287
Same as item 25-940 but 20 KVA, ATS Panels. Each 25-942 105341
Same as item 29-940 but 30 KVA, ATS Panels. Each 25-943 116801
Same as item 25-940 but 40 KVA, ATS Panels. Each 25-944 124949
Same as item 25-940 but 50 KVA, ATS Panels. Each 25-945 139832
Same as item 25-940 but 60 KVA, ATS Panels Each 25-946 150221
Same as item 25-940 but 75 KVA, ATS Panels. Each 25-947 164658
Same as item 25-940 but 100 KVA, ATS Panels. Each 25-948 178137
Same as item 25-940 but 125 KVA, ATS Panels. Each 25-949 275208
Same as item 25-940 but 150 KVA, ATS Panels. Each 25-950 311548
Same as item 25-940 but 175 KVA, ATS Panels. Each 25-951 339628
Same as item 25-940 but 200 KVA, ATS Panels. Each 25-952 436644
Same as item 25-940 but 250 KVA, ATS Panels. Each 25-953 490229
Same as item 25-940 but 300 KVA, ATS Panels. Each 25-954 541163
Same as item 25-940 but 400 KVA, ATS Panels. Each 25-955 781163
Same as item 25-940 but 500 KVA, ATS Panels. Each 25-956 1802025
Same as item 25-940 but 600 KVA, ATS Panels. Each 25-957 1922025
Same as item 25-940 but 700 KVA, ATS Panels. Each 25-958 1955161
Same as item 25-940 to 25-943, but fixing only. Each 25-959 465
Same as item 25-944 to 25-946, but fixing only. Each 25-960 698
Same as item 25-947 to 25-949, but fixing only. Each 25-961 814
Same as item 25-950 to 25-952, but fixing only. Each 25-962 930
Same as item 25-953 to 25-955, but fixing only. Each 25-963 1162
Same as item 25-956 to 25-958, but fixing only. Each 25-964 2025
Add to item 25-940 to 25-943 or 25-959 if removal only. Each 25-965 349
Add to item 25-944 to 25-946 or 25-960 if removal only. Each 25-966 523
Add to item 25-947 to 25-949 or 25-961 if removal only. Each 25-967 608
Add to item 25-950 to 25-952 or 25-962 if removal only. Each 25-968 697
Add to item 25-953 to 25-955 or 25-963 if removal only. Each 25-969 870
Add to item 25-956 to 25-958 or 25-964 if removal only. Each 25-970 1418
CABLE TRAY
Cable tray out of 16 Guage, GI sheet, without cover, Metre 25-971 923
complete in jointing plates. Cable tray size 4” x 2”.
Same as item 25-971 but Cable tray size 6” x 2”. Metre 25-972 1071
Same as item 25-971 but Cable tray size 9” x 2”. Metre 25-973 1300
Same as item 25-971 but Cable tray size 12” x3”. Metre 25-974 1797
Same as item 25-971 but Cable tray size 15” x 3”. Metre 25-975 2027
Same as item 25-971 but Cable tray size 18” x 4”. Metre 25-976 2524
Same as item 25-971 but Cable tray size 24” x 4”. Metre 25-977 2981
Same as item 25-971 to 25-973, but fixing only. Metre 25-978 233
Same as item 25-974 to 25-975, but fixing only. Metre 25-979 349
Same as item 25-976 to 25-977, but fixing only. Metre 25-980 465
Add to item 25-971 to 25-973 or 25-978, but fixing only. Metre 25-981 140
Add to item 25-974 to 25-975 or 25-978, but fixing only. Metre 25-982 233
Add to item 25-976 to 25-977 or 25-980, but fixing only. Metre 25-983 349
Street Light
LED Road Street Light, 22 Watts, 220-240 Volts, “Standard”, Each 25-984 4428
complete supply and fixing.
Same as item 25-984 but Deluxe. Each 25-985 8928
Same as item 25-984 but Premium. Each 25-986 15948
Same as item 25-984 but 27 watt Standard. Each 25-987 5628
Same as item 25-987 but Deluxe. Each 25-988 9348
Same as item 25-987 but Premium. Each 25-989 17028
Same as item 25-984 but 50 watt Standard. Each 25-990 6828
Same as item 25-990 but Deluxe. Each 25-991 12768
Same as item 25-990 but Premium. Each 25-992 24228
Same as item 25-984 but 60 watt Standard. Each 25-993 11628
Same as item 25-993 but Deluxe. Each 25-994 13128
Same as item 25-993 but Premium. Each 25-995 19048
Same as item 25-984 but 70 watt Standard. Each 25-996 10428
Same as item 25-996 but Deluxe. Each 25-997 21228
Same as item 25-996 but Premium. Each 25-998 35428
Same as item 25-984 but 90 watt Standard. Each 25-999 13428
Same as item 25-999 but Deluxe. Each 25-1000 24892
Same as item 25-999 but Premium. Each 25-1001 36427
Same as item 25-984 but 100 & 110 watt Standard. Each 25-1002 31428
Same as item 25-1002 but Deluxe. Each 25-1003 32628
Same as item 25-1002 but Premium. Each 25-1004 44328
Same as item 25-984 but 120 & 130 watt Standard. Each 25-1005 21978
Same as item 25-1005 but Deluxe. Each 25-1006 34128
Same as item 25-1005 but Premium. Each 25-1007 41910
Same as item 25-984 but 140 & 150 watt Standard. Each 25-1008 25728
Same as item 25-1008 but Deluxe. Each 25-1009 38328
Same as item 25-1008 but Premium. Each 25-1010 56148
Same as item 25-984 but 160 & 170 watt Standard. Each 25-1011 27228
Same as item 25-1011 but Deluxe. Each 25-1012 43428
Same as item 25-1011 but Premium. Each 25-1013 66648
Same as item 25-984 but 180 watt Standard. Each 25-1014 38328
Same as item 25-1014 but Deluxe. Each 25-1015 38388
Same as item 25-1014 but Premium. Each 25-1016 67038
Same as item 25-984 to 25-1016 but fixing only. Each 25-1017 960
Add to item 25-984 to 25-1016 or 25-1017 if removal only. Each 25-1018 518
Flood Light
LED Flood Security Light, 30 Watts, 220-240 Volts, approved Each 25-1019 4118
type “Standard”, complete supply and fixing.
Same as item 25-1019 but Deluxe. Each 25-1020 5001
Same as item 25-1019 but Premium. Each 25-1021 15841
Same as item 25-1019 but 50 watt Standard. Each 25-1022 5541
Same as item 25-1022 but Deluxe. Each 25-1023 7261
Same as item 25-1022 but Premium. Each 25-1024 23271
Same as item 25-1019 but 70 watt Standard. Each 25-1025 10221
Same as item 25-1025 but Deluxe. Each 25-1026 12381
Same as item 25-1025 but Premium. Each 25-1027 24021
Same as item 25-1019 but 100 & 110 watt Standard. Each 25-1028 11142
Same as item 25-1028 but Deluxe. Each 25-1029 22322
Same as item 25-1028 but Premium. Each 25-1030 36473
Same as item 25-1019 but 120 watt Standard. Each 25-1031 12622
Same as item 25-1031 but Deluxe. Each 25-1032 20422
Same as item 25-1031 but Premium. Each 25-1033 27022
Same as item 25-1019 but 160 watt Standard. Each 25-1034 16822
Same as item 25-1034 but Deluxe. Each 25-1035 21782
Same as item 25-1034 but Premium. Each 25-1036 34222
Same as item 25-1019 but 200 watt Standard. Each 25-1037 18022
Same as item 25-1037 but Deluxe. Each 25-1038 28622
Same as item 25-1037 but Premium. Each 25-1039 45622
Same as item 25-1019 but 220 watt Standard. Each 25-1040 29422
Same as item 25-1040 but Deluxe. Each 25-1041 48022
Same as item 25-1040 but Premium. Each 25-1042 68422
Same as item 25-1019 but 245 watt Standard. Each 25-1043 45622
Same as item 25-1043 but Deluxe. Each 25-1044 63022
Same as item 25-1043 but Premium. Each 25-1045 91582
Same as item 25-1019 but 315 watt Standard. Each 25-1046 55822
Same as item 25-1046 but Deluxe. Each 25-1047 64222
Same as item 25-1046 but Premium. Each 25-1048 66022
Same as item 25-1019 but 350 watt Standard. Each 25-1049 66622
Same as item 25-1049 but Deluxe. Each 25-1050 72022
Same as item 25-1049 but Premium. Each 25-1051 78622
High Bay Light LED, 100 watt, stiff pendent 220-240 Volts, Each 25-1052 22582
approved type, ceiling mounted round type “Standard”,
complete supply and fixing.
Same as item 25-1052 but Deluxe. Each 25-1053 26062
Same as item 25-1052 but Premium. Each 25-1054 31702
Same as item 25-1052 but 150 watt Standard. Each 25-1055 22462
Same as item 25-1055 but Deluxe. Each 25-1056 42622
Same as item 25-1055 but Premium. Each 25-1057 43054
Same as item 25-1019 to 25-1057 but fixing only. Each 25-1058 388
Add to item 25-1019 to 25-1057 or 25-1058 if removal only. Each 25-1059 388
Same as item 26-66 to 26-67, 24-70, but fixing only. Each 26-72 690
Add to item 26-64 to 26-65 or 26-71, if removal only. Each 26-73 388
Add to item 26-66 to 26-67 or 26-72, if removal only. Each 26-74 518
Instant Gas water heater, complete with burner pilot, Ignition Each 26-75 11625
coil Operated DC 1.5 Volt Battery and safety valve, 6 lit per
min capacity, supply and fixing.
Same as item 26-75, but 8 lit per min. Each 26-76 15225
Same as item 26-75, but 10 lit per min. Each 26-77 17145
Same as item 26-75 to 26-77, but fixing only. Each 26-78 345
Add to item 26-75 to 26-77 or 26-78 if removal only. Each 26-79 259
Gas light best quality approved type supply and fixing. Each 26-80 753
Same as item 26-80, but fixing only. Each 26-81 86
Add to item 26-80 or 26-81 if removal only. Each 26-82 52
Gas Room Heater
Gas room heater of 20 SWG Black Sheet, complete with pilot, Each 26-83 6632
single burner, supply and fixing.
Gas room heater of 20SWG Black Sheet, complete with pilot, Each 26-84 8005
double burner, supply and fixing.
Same as item 26-83 to 26-84, but fixing only. Each 26-85 518
Add to item 26-83 to 26-85, if removal only. Each 26-86 388
Gas Burner (Chullah)
Gas burner (Chullah) of 20 SWG Black Sheet, single burner, Each 26-87 2257
supply and fixing.
Same as item 26-87, but double burner. Each 26-88 3638
Build in burner non Magnetic steel top, one Large super Each 26-89 18734
prime burner and 4 medium burner, non-stick paint coated,
auto ignition 3, volt battery operated, supply and fixing.
Same as item 26-95, but 34”, 3 burner, double door. Each 26-96 23678
Same as item 26-95, but 34”, 5 burner single door. Each 26-97 30704
Same as item 26-95, but 5 burners double door. Each 26-98 31958
Same as item 26-95, to 26-98, but fixing only. Each 26-99 518
Add to item 26-9 to 26-96, if removal only. Each 26-100 388
Micro hose (Fire resistant) 3 feet, long complete with brass Each 26-101 3773
coupling on both end supply & fixing.
Same as item 26-101 but 4 feet long. Each 26-102 4973
Same as item 26-101 but 6 feet long. Each 26-103 7373
Same as Item 26-101 to 26-102 but fixing only. Each 26-104 173
Add to Item 26-101 to 26-102 or 26-103 if removal only. Each 26-105 138
Miscellaneous
Thermostat of gas water heater complete with thermocouple Each 26-106 2678
wire and pilot tube, supply and fixing.
Same as item 26-106, but fixing only. Each 26-107 518
Add to item 26-106 or 26-107, if removal only. Each 26-108 388
Audco valve, high pressure, MW-13 type, 100 mm dia flanged Each 26-109 12696
with nuts and bolts, complete, supply and fixing.
Muller Tee 20 mm dia welded, supply and fixing. Each 26-113 720
Same as item 26-113, but 25 mm dia. Each 26-114 1536
Same as item 26-113, but 50 mm dia. Each 26-115 3582
Same as item 26-113 or 26-114, but fixing only. Each 26-116 150
Same as item 26-115, but fixing only. Each 26-117 244
Add to item 26-113 to 26-117, if removal only. Each 26-118 112
Sui gas regulator, “Peeble type”, domestic, supply and fixing. Each 26-119 1119
Gas Heater, flue pipe assembly, fabricated with 24 gauge, GI Each 26-127 360
sheet, supply and fixing.
Same as item 26-127, but fixing only. Each 26-128 61
Add to item 26-127 to 26-128, if removal only. Each 26-129 46
Locking cock brass, 20 mm dia, gas quality, supply and fixing. Each 26-130 691
Add to item 26-138 to 26-139 or 26-142 if removal only. Metre 26-145 129
Fitting
Butt Fusion joint, for pipe 20 mm dia, joint complete as Each 26-146 960
specified.
Same as item 26-146 but for pipe 25 mm dia. Each 26-147 960
Same as item 26-146 but for pipe 40 mm dia. Each 26-148 960
Same as item 26-146 but for pipe 50 mm or 75 mm dia. Each 26-149 1200
Same as item 26-146 but for pipe 100 mm dia. Each 26-150 1800
Same as item 26-146 but for pipe 160 mm dia. Each 26-151 1800
Elbow 20 mm for gas pipe MDPE 80, supply and fixing. Each 26-152 226
Same as item 26-152 but 25 mm dia. Each 26-153 635
Same as item 26-152 but 40 mm or 50 mm dia. Each 26-154 850
Same as item 26-152, but 75 mm dia. Each 26-155 4684
Same as item 26-152, but 100 mm dia. Each 26-156 6086
Same as item 26-152, but 160 mm dia. Each 26-157 20907
Cap, 20 mm or 25 mm dia, supply and fixing. Each 26-158 455
Same as item 26-158, but 40 mm to 50 mm dia. Each 26-159 635
Same as item 26-158, but 75 mm to 100 mm dia. Each 26-160 4269
Same as item 26-158, but 160 mm dia. Each 26-161 11966
Tee, 20mm or 25mm dia, supply and fixing. Each 26-162 370
Same as item 26-162, but 40 mm or 50 mm dia. Each 26-163 1269
Same as item 26-62, but 75 mm or 100 mm dia. Each 26-164 4702
Same as item 26-162 but 160 mm dia. Each 26-165 6753
Tapping Tee, Reducing, 25 x 20 mm or 50 x 20 mm dia, Each 26-166 1269
supply and fixing.
Same as item 26-166, but 100 x 20 mm dia. Each 26-167 4291
Same as item 26-166, but 100 x 25 mm dia. Each 26-168 5420
Same as item 26-166, but 100 x 50 mm dia. Each 26-169 5745
Same as item 26-166, but 160 x 25 mm dia. Each 26-170 5898
Same as item 26-166, but160 x 50 mm dia. Each 26-171 6001
Same as item 26-152, 26-153, 26-158 or 26-159, but fixing Each 26-172 35
only.
Same as item 26-154, 26-155, 26-160 to 26-163 or 26-166, Each 26-173 69
but fixing only.
Same as item 26-156, 26-157, 26-164, 26-165, 26-167 or 26- Each 26-174 86
168, but fixing only.
Same as item 26-169 to 26-171, but fixing only. Each 26-175 104
Add to item 26-152, 26-153, 26-158, 26-159 or 26-172, if Each 26-176 26
removal only.
Add to item 26-154, 26-155, 26-160 to 26-163, 26-166 or 26- Each 26-177 52
173, if removal only.
Add to item 26-156, 26-157, 26-164, 26-165, 26-167 or 26- Each 26-178 65
168 or 26-173, if removal only.
Add to item 26-169 to 26-171or 26-174, if removal only. Each 26-179 78
Multi Gas Detector with Control System to detect gas leakage Each 26-180 36414
and automatically shut down gas supply, Provision & fixing.
Non Industrial at home usage Natural Gas (Methane) Each 26-181 20350
Detector with LCD Display Alarm, Supply & Fixing.
Sensitive Gas Detector, plug in with LCD Display and alarm, Each 26-182 2920
supply and fixing.
Same as Item 26-180 to 26-182 but fixing only. Each 26-183 144
Add to item 26-180 to 26-182 if removal only. Each 26-184 72
Sound liner thickness 1 inch, for GI duct where required, Sqm 27-20 16350
supply and fixing.
Same as item 27-20, but 2 inch thickness. Sqm 27-21 28774
Same as item 27-16, but fixing only. Sqm 27-22 930
Same as item 27-17, but fixing only. Sqm 27-23 930
Same as item 27-18, but fixing only. Sqm 27-24 207
Same as item 27-19, but fixing only. Sqm 27-25 207
Same as item 27-20, but fixing only. Sqm 27-26 1350
Same as item 27-21, but fixing only. Sqm 27-27 1800
Added to item 27-16 or 27-22, if removal only. Sqm 27-28 698
Added to item 27-17 or 27-23, if removal only. Sqm 27-29 698
Added to item 27-18 or 27-24, if removal only. Sqm 27-30 155
Added to item 27-19 or 27-25, if removal only. Sqm 27-31 155
Added to item 27-20 or27-26, if removal only. Sqm 27-32 1013
Added to item 27-21 or 27-27, if removal only. Sqm 27-33 1013
Supply/ Returns Exhaust Air Diffusers
Supply air diffusers, supply and fixing. Sqm 27-34 21702
Return air diffusers, supply and fixing. Sqm 27-35 21702
Return air grill, supply and fixing. Sqm 27-36 20112
Exhaust air diffusers, supply and fixing. Sqm 27-37 21702
Same as item 27-34 to 27-37, but fixing only. Sqm 27-38 1035
Add to item 27-34 to 27-37 or 27-38, if removal only. Sqm 27-39 776
Balancing Valve for chilled/hot water, 25mm dia (KITZ Japan) Each 27-40 7279
supply and fixing.
Same as Item 27-40, but 32mm dia. Each 27-41 7758
Same as Item 27-40, but 40mm dia. Each 27-42 9678
Same as Item 27-40, but 50mm dia. Each 27-43 11958
Same as Item 27-40, but 65mm dia. Each 27-44 16878
Same as Item 27-40, but flanged and drilled BS Table 18-1-9 Each 27-45 23987
75mm dia.
Same as Item 27-45, but 100mm dia. Each 27-46 41168
Same as Item 27-45, but 125mm dia. Each 27-47 59967
Same as Item 27-45, but 150mm dia. Each 27-48 94767
Same as Item 27-45, but 200mm dia. Each 27-49 142767
Non-Return Valve screwed 75mm dia, (Kitz Japan) flanged Each 27-50 11852
and drilled B.S Table 18-1-9.
Same as Item 27-50, but 100mm dia. Each 27-51 15848
Same as Item 27-50, but 125mm dia. Each 27-52 19532
Same as Item 27-50, but 150mm dia. Each 27-53 21453
Same as Item 27-50, but 200mm dia. Each 27-54 34053
Y Strainer 75mm dia (Kitz Japan), flanged and drilled, B.S Each 27-55 11132
Table 18-1-9 supply and fixing.
Same as Item 27-55, but 100mm dia. Each 27-56 14648
Same as Item 27-55, but 125mm dia. Each 27-57 18368
Same as Item 27-55, but 150mm dia. Each 27-58 22053
Same as Item 27-55, but 200mm dia. Each 27-59 34053
Automatic Air Vent Valve, 20mm dia (Kitz Japan) supply and Each 27-60 1818
fixing.
Same as Item 27-60, but 25mm dia. Each 27-61 2958
Same as Item 27-40 to 27-44, 27-60 to 27-61, but fixing only. Each 27-62 78
Same as Item 27-45 to 27-49, 27-50 to 27-54, 27-55 to 27-59, Each 27-63 417
but fixing only.
Add to Item 27-40 to 27-44, 27-60 to 27-61 and 27-62 if Each 27-64 262
removal only.
Add to Item 27-45 to 27-49, 27-50 to 27-54, 27-55 to 27-59 Each 27-65 155
and 27-63, if removal only.
Pipe line digital thermostat, supply and fixing (Digital). Each 27-66 54431
Pipe line pressure gauge, supply and fixing. Each 27-67 18431
Same as item 27-66 and 27-67, but fixing only. Each 27-68 431
Added to item 27-66 and 27-67 or 27-68, if removal only. Each 27-69 324
Installation AC Unit, wall mounted split type upto 1.5 Ton Each 27-70 3578
(except cost of AC unit), kit and electric wiring.
Same as item 27-70, but 2 Ton capacity. Each 27-71 3578
Installation AC unit, floor mounted split type, 3 phase, 5 Ton Each 27-72 6705
capacity, (except cost of AC unit), kit, electric wiring and PCC
foundation.
Same as item 27-72, but upto 10 Ton capacity. Each 27-73 6705
Same as item 27-72, but upto 16 Ton capacity Each 27-74 18765
Same as item 27-72, but upto 20 Ton capacity. Each 27-75 23160
Same as item 27-72, but upto 25 Ton capacity. Each 27-76 27555
Refrigerant Piping
Copper tube ¼ “ dia, supply and fixing. Metre 27-77 357
Same as item 27-77, but ⅜ “ dia. Metre 27-78 538
Same as item 27-77, but ½ “ dia. Metre 27-79 808
Same as item 27-77, but ⅝ “ dia. Metre 27-80 1003
Same as item 27-77, but ¾” dia. Metre 27-81 1297
Same as item 27-77, but ⅞” dia. Metre 27-82 1526
Same as item 27-77, but 1-⅛” dia. Metre 27-83 2267
Same as item 27-77, but 1-⅜” dia. Metre 27-84 3005
Same as item 27-77, but 1-⅝” dia. Metre 27-85 3916
Same as item 27-77 to 27-85, but fixing only. Each 27-86 86
Add to item 27-77 to 27-85 or 27-86, if removal only. Each 27-87 69
Insulation elastomeric nitrite rubber Pipe for Copper tube ¼“ Metre 27-88 105
dia, as per complete specification, supply and fixing.
Same as item No. 27-88, but size 3/8 “ dia. Metre 27-89 111
Same as item 27-88 but ½“ dia. Metre 27-90 117
Same as item No.27-88, but size ⅝ “ dia supply. Metre 27-91 123
Same as item No.27-88, but size 3/4” dia. Metre 27-92 129
Same as item No.27-88, but size 7/8” dia. Metre 27-93 135
Same as item No.27-88, but size 1-1/8” dia. Metre 27-94 165
Same as item No.27-88, but size 1-3/8” dia. Metre 27-95 183
Same as item No.27-88, but size 1-5/8” dia supply and fixing. Metre 27-96 213
Compressor protection
a. Compressor suction
b. Exhaustion Pressure Protection
c. Compression Ratio Protection
d. Exhausting temperature protection
e. Oil Return protection
Inverter Protection
a. Inverter temperature protection
b. Voltage Protection
System Protection
a. Ventilator pressure protection
b. Four-way valve protection
c. Indoor and outdoor temperature protection
d. Sub cooling protection
Electric Protection
a. Voltage phase-failure
b. Current protection
c. Motor protection
d. Protecting from Lightening
(Complete in all respects)
Same as item 27-103, but rated capacity 10HP. Complet 27-104 1241503
e Job
Same as item 27-103, but rated capacity 12HP. Complet 27-105 1453866
e Job
Same as item 27-103, but rated capacity 14HP. Complet 27-106 1657493
e Job
Same as item 27-103, but rated capacity 16HP. Complet 27-107 1803136
e Job
Same as item 27-103, but rated capacity 18HP, with 2 x Complet 27-108 1966319
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 20HP, with 2 x Complet 27-109 2132928
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 22HP, with 2 x Complet 27-110 2679346
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 24HP, with 2 x Complet 27-111 2898996
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 26HP, with 2 x Complet 27-112 3111359
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 28HP, with 2 x Complet 27-113 3314987
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 30HP, with 2 x Complet 27-114 3460628
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 32HP, with 2 x Complet 27-115 3623812
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 34HP, with 3 x Complet 27-116 4149234
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 36HP, with 3 x Complet 27-117 4361597
digital scroll enhance vapour injection compressor. e Job
Same as item 27-103, but rated capacity 38HP, with 4 x Complet 27-118 4442036
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 40HP, with 4 x Complet 27-119 4710866
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 42HP, with 4 x Complet 27-120 4914494
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 44HP, with 4 x Complet 27-121 5060137
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 46HP, with 4 x Complet 27-122 5281303
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 48HP, with 4 x Complet 27-123 5426947
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 50HP, with 4 x Complet 27-124 5590130
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 52HP, with 4 x Complet 27-125 5735773
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 54HP, with 4 x Complet 27-126 5898956
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 56HP, with 4 x Complet 27-127 6065566
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 58HP, with 6 x Complet 27-128 6232175
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 60HP, with 6 x Complet 27-129 6398784
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 62HP, with 6 x Complet 27-130 7084440
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103, but rated capacity 64HP, with 6 x Complet 27-131 7247623
digital scroll enhance vapours injection compressor. e Job
Same as item 27-103 to 27-114, but fixing only. Complet 27-132 24000
e Job
Same as item 27-115 to 27-123, but fixing only. Complet 27-133 36000
e Job
Same as item 27-124 to 27-127, but fixing only. Complet 27-134 42000
e Job
Same as item 27-128 to 27-131, but fixing only. Complet 27-135 48000
e Job
Add to item 27-103 to 27-114 or 27-132, if removal only. Complet 27-136 12000
e Job
Add to item 27-115 to 27-123 or 27-133, if removal only. Complet 27-137 18000
e Job
Add to item 27-124 to 27-127 or 27-134, if removal only. Complet 27-138 21000
e Job
Add to item 27-128 to 27-131 or 27-135, if removal only. Complet 27-139 24000
e Job
Indoor Unit
Supply & fixing, testing and commissioning of VRF indoor Complet 27-140 51600
unit, cassette type, 4-way, suitable operation on AC220 volts, e Job
50HZ, electric supply, complete in all respects, rated capacity
0.75 Ton.
Same as item 27-140, but rated capacity, 1 Ton. Complet 27-141 54000
e Job
Same as item 27-140, but rated capacity, 1.25 Ton. Complet 27-142 75600
e Job
Same as item 27-140, but rated capacity, 1.50 Ton. Complet 27-143 81000
e Job
Same as item 27-140, but rated capacity, 2 Ton. Complet 27-144 108000
e Job
Same as item 27-140, but rated capacity, 2.50 Ton. Complet 27-145 135000
e Job
Same as item 27-140, but rated capacity, 3 Ton. Complet 27-146 162000
e Job
Supply, fixing, testing and commissioning of VRF indoor unit Complet 27-147 38400
wall mounted type, suitable operation on AC220 volts, 50 HZ, e Job
electric supply, complete in all respects, rated capacity 0.75
Ton.
Same as item 27-147, but rated capacity, 1 Ton. Complet 27-148 42000
e Job
Same as item 27-147, but rated capacity, 1.25 Ton. Complet 27-149 57000
e Job
Same as item 27-147, but rated capacity, 1.50 Ton. Complet 27-150 63000
e Job
Same as item 27-147, but rated capacity, 2 Ton. Complet 27-151 84000
e Job
Same as item 27-147, but rated capacity, 2.50 Ton. Complet 27-152 105000
e Job
Same as item 27-147, but rated capacity, 3 Ton. Complet 27-153 126000
e Job
Same as item 27-140 to 27-143, 27-147 to 27-150, but fixing Complet 27-154 4000
only. e Job
Same as item 27-144 to 27-146, 27-151 to 27-153, but fixing Complet 27-155 4500
only. e Job
Add to item 27-140 to 27-143, 27-147 to 27-150 or 27-154,if Complet 27-156 2000
removal only. e Job
Add to item 27-144 to 27-146, 27-151 to 27-153 or 27-155, if Complet 27-157 2250
removal only. e Job
Air Cooled Self Contained Package Air – Conditioners
Supply, installation, testing and commissioning of Package Air Each 27-158 1125000
Conditioning Units with compressors, electrical controls,
temperature & pressured controls with special designed heat
exchange coils must be of USA / EU origin to work at high
ambient temperature perfectly. Unit must be completely
wired, piped, charged and run tested in the factory before
shipment to minimize installation time. Complete in all
respect, 5 ton capacity.
Same as item 27-158, but 7.5 ton Capacity. Each 27-159 1687500
Same as item 27-158, but 10 ton Capacity. Each 27-160 2250000
Same as item 27-158, but 12 TR Capacity. Each 27-161 2700000
Same as item 27-158, but 15 ton Capacity. Each 27-162 3375000
Same as item 27-158, but 20 ton Capacity. Each 27-163 4560000
Same as item 27-158, but 25 ton Capacity. Each 27-164 4980000
Same as item 27-158, but 30 ton Capacity. Each 27-165 5400000
Same as item 27-158, but 40 ton Capacity. Each 27-166 7200000
Same as item 27-158, but 50 ton Capacity. Each 27-167 9840000
Same as item 27-158, but 60 ton Capacity. Each 27-168 10560000
Same as item 27-158, but 70 ton Capacity. Each 27-169 11760000
Air Cooled Self Contained Package Air – Conditioners
(Asian Origin)
Supply, installation, testing and commissioning of Package Air Each 27-170 912000
Conditioning Units, with compressors, electrical controls,
temperature & pressured controls, with special designed heat
exchange coils, to work at high ambient temperature
perfectly. Unit must be completely wired, piped, charged and
run tested in the factory before shipment to minimize
installation time. Complete in all respect, 5 ton capacity.
Same as item 27-170, but 7.5 ton Capacity. Each 27-171 1176000
Same as item 27-170, but 10 ton Capacity. Each 27-172 1411200
Same as item 27-170, but 12 ton Capacity. Each 27-173 1881600
Same as item 27-170, but 15 ton Capacity. Each 27-174 2352000
Same as item 27-170, but 20 ton Capacity. Each 27-175 2822400
Same as item 27-170, but 25 ton Capacity. Each 27-176 3528000
Same as item 27-170, but 30 ton Capacity. Each 27-177 4704000
Same as item 27-170, but 40 ton Capacity. Each 27-178 5880000
Same as item 27-170, but 50 ton Capacity. Each 27-179 7056000
Same as item 27-170, but 60 ton Capacity. Each 27-180 8232000
Same as item 27-170, but 70 ton Capacity. Each 27-181 10584000
Same as item 27-158 to 27-161 or 27-170 to 27-173, but Each 27-182 9000
fixing only.
Same as item 27-162 to 27-165 or 27-174 to 27-177, but Each 27-183 22500
fixing only.
Same as item 27-166 to 27-169 or 27-178 to 27-182, but Each 27-184 52500
fixing only.
Add to item 27-158 to 27-161, 27-170 to 27-173 or 27-182, if Each 27-185 4500
removal only.
Add to item 27-162 to 27-165, 27-174 to 27-177 or 27-183, if Each 27-186 11250
removal only.
Add to item 27-166 to 27-169, 27-178 to 27-182 or 27-184, if Each 27-187 26250
removal only.
Air Handling Unit
Supply, installation, testing and commissioning of AHU Each 27-188 1285625
(Normal) with refrigerant, copper piping as specified of
EU/US origin with AHRI/ Euro-vent certified of 10 Ton,
suitable on AC supply 400V, 3 phase, 50 HZ complete all as
specified.
Same as item 27-188, but 15 ton Capacity. Each 27-189 1658914
Same as item 27-188, but 20 ton Capacity. Each 27-190 2081506
Same as item 27-188, but 25 ton Capacity. Each 27-191 2459550
Same as item 27-188, but 30 ton Capacity. Each 27-192 2820272
Same as item 27-188, but 35 ton Capacity. Each 27-193 3174115
Same as item 27-188, but 40 ton Capacity. Each 27-194 3510341
Same as item 27-188, but 45 ton Capacity. Each 27-195 3720267
Same as item 27-188, but 50 ton Capacity. Each 27-196 4074840
Same as item 27-188, but 55 ton Capacity. Each 27-197 4347608
Same as item 27-188, but 60 ton Capacity. Each 27-198 4652337
Supply, installation, testing and commissioning of AHU Each 27-199 1730794
(Hygiene) with refrigerant copper piping all as specified of
EU/US origin with AHRI/Euro-vent certified of 10Ton,
capacity, suitable on AC supply, 400V, 3ph, 50 HZs, complete
all spd.
Same as item 27-199, but 15 ton Capacity. Each 27-200 2381725
Same as item 27-199, but 20 ton Capacity. Each 27-201 2992384
Same as item 27-199, but 25 ton Capacity. Each 27-202 3673901
Same as item 27-199, but 30 ton Capacity. Each 27-203 4329264
Same as item 27-199, but 35 ton Capacity. Each 27-204 4944121
Same as item 27-199, but 40 ton Capacity. Each 27-205 5397824
Same as item 27-199, but 45 ton Capacity. Each 27-206 5930597
Same as item 27-199, but 50 ton Capacity. Each 27-207 6441742
Same as item 27-199, but 55 ton Capacity. Each 27-208 6861373
Same as item 27-199, but 60 ton Capacity. Each 27-209 7309340
Air Handling Unit ( Asian Origin)
Supply, installation, testing and commissioning of AHU Each 27-210 876000
(Normal) with refrigerant, copper piping as specified for Asian
Origin 10 Ton, suitable on AC supply 400V, 3phase, 50HZs,
complete all as specified.
Same as item 27-210, but 15 ton Capacity. Each 27-211 1404000
Same as item 27-210, but 20 ton Capacity. Each 27-212 1800000
Same as item 27-210, but 25 ton Capacity. Each 27-213 2196000
Same as item 27-210, but 30 ton Capacity. Each 27-214 2720640
Same as item 27-210, but 35 ton Capacity. Each 27-215 3054000
Same as item 27-210, but 40 ton Capacity. Each 27-216 3384000
Same as item 27-210, but 45 ton Capacity. Each 27-217 4044000
Same as item 27-210, but 50 ton Capacity. Each 27-218 4704000
Same as item 27-210, but 55 ton Capacity. Each 27-219 4764000
Same as item 27-210, but 60 ton Capacity. Each 27-220 5364000
Supply, installation, testing and commissioning of AHU Each 27-221 983400
(Hygiene) with refrigerant copper piping all as specified for
Asian Origin, 10 Ton Capacity, Suitable on AC supply, 400V,
3ph, 50 HZs complete all spd.
Same as item 27-221, but 15 ton Capacity. Each 27-222 1331701
Same as item 27-221, but 20 ton Capacity. Each 27-223 1748734
Same as item 27-221, but 25 ton Capacity. Each 27-224 2170770
Same as item 27-221, but 30 ton Capacity. Each 27-225 2406468
Same as item 27-221, but 35 ton Capacity. Each 27-226 2593656
Same as item 27-221, but 40 ton Capacity. Each 27-227 3169243
Same as item 27-221, but 45 ton Capacity. Each 27-228 3495662
Same as item 27-221, but 50 ton Capacity. Each 27-229 3780731
Same as item 27-221, but 55 ton Capacity. Each 27-230 4215758
Same as item 27-221, but 60 ton Capacity. Each 27-231 4627610
Supply, installation, testing and commissioning of AHU Each 27-232 2581974
(Medical grade) with pre & bag filters refrigerant copper
piping all as specified of Asian Origin,10 Ton Capacity,
Suitable on AC supply, 400V, 3ph, 50HZs complete in all
respect as per drawing & specification.
Same as item 27-232, but 15 ton Capacity. Each 27-233 3820374
Same as item 27-232, but 20 ton Capacity. Each 27-234 5058774
Same as item 27-232, but 25 ton Capacity. Each 27-235 6336774
Same as item 27-232, but 30 ton Capacity. Each 27-236 7492374
Same as item 27-188 to 27-191, 27-199 to 27-202, 27-210 to Each 27-237 18774
27-213, 27-221 to 27-224 or 27-232 to 27-236, but fixing
only.
Same as item 27-192 to 27-194, 27-203 to 27-205, 27-214 to Each 27-238 33750
27-216 or 27-225 to 27-227, but fixing only.
Same as item 27-195 to 27-198, 27-206 to 27-209, 27-217 to Each 27-239 45000
27-220 or 27-228 to 27-231, but fixing only.
Add to item 27-188 to 27-191, 27-199 to 27-202, 27-210 to Each 27-240 9387
27-213, 27-221 to 27-224, 27-232 to 27-236 or 27-237, if
removal only.
Add to item 27-192 to 27-194, 27-203 to 27-205, 27-214 to Each 27-241 16875
27-216, 27-225 to 27-227 or 27-238, if removal only.
Add to item 27-195 to 27-198, 27-206 to 27-209, 27-217 to Each 27-242 22500
27-220, 27-228 to 27-231 or 27-239, if removal only.
Supply, installation, testing and commissioning of air cooled Each 27-243 838000
condensing unit (CU), direct expansion (Dx) type, of EU/US
origin, AHRI/Euro vent certified, with power supply of 400 V,
3ph, 50 HZs with all necessary controls and compressor scroll
type, semi hermetic, of 5 ton capacity, complete in all
respect.
Same as item 27-243, but 10 ton Capacity. Each 27-244 1526005
Same as item 27-243, but 15 ton Capacity. Each 27-245 2173139
Same as item 27-243, but 20 ton Capacity. Each 27-246 2832496
Same as item 27-243, but 25 ton Capacity. Each 27-247 3419220
Same as item 27-243, but 30 ton Capacity. Each 27-248 4057807
Same as item 27-243, but 35 ton Capacity. Each 27-249 4695420
Same as item 27-243, but 40 ton Capacity. Each 27-250 5224891
Same as item 27-243, but 45 ton Capacity. Each 27-251 5746652
Same as item 27-243, but 50 ton Capacity. Each 27-252 6331136
Same as item 27-243, but 55 ton Capacity. Each 27-253 6773497
Same as item 27-243, but 60 ton Capacity. Each 27-254 7204633
Supply, installation, testing and commissioning of air cooled Each 27-255 624000
condensing unit (CU), direct expansion (Dx) type, of Asian
origin with power supply of 400V, 3ph, 50HZs with all
necessary controls and compressor scroll type, semi
hermetic, of 5 ton capacity, complete in all respect.
Passengers / cargo lift with motor 415 V, 3ph, AC 50Hzs Each 27-292 5200000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF drive) complete with all
standard accessories, for upto 800 Kg, including all applicable
safeties complete in all respect as per drawing and
specification. As latest edition of applicable standards of
ANSI, ASME, BS/EN, AWS, NFPA, ASTM, NEMA and IEE etc.
Asian origin.
Passengers / cargo lift with motor 415 V, 3ph, AC, 50Hzs Each 27-293 5300000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, for upto 1000 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM, NEMA and IEE etc. Asian origin.
Passengers / cargo lift with motor 415 V, 3ph, AC, 50Hzs Each 27-294 6000000
supply, suitable to serve 07 floors with AC Variable Voltage &
Variable Frequency drive (VVVF) complete with all standard
accessories, for upto 1600 Kg, including all applicable safeties
complete in all respect as per drawing and specification. As
latest edition of applicable standards of ANSI, ASME, BS/EN,
AWS, NFPA, ASTM,NEMA and IEE etc. Asian origin.
Servicing / Maintenance / Monthly inspection as per OEM One Job 27-295 15000
standard of Elevators, all as specified.
GANTRY EOT CRANES
Supply, fixing, Testing and Commissioning of EOT Crane, span Each 27-296 11225000
12 metre, Bay length 15.2 metre, Height of lift 7.76 metre
capacity 5 Tonne single girder, including cabals, Control
Panels and EOT kit suitable operation on 410/220 Volts, 3
Phase with NL, complete in all respect as per drawings and
specification.
Same as Item 27-296, but Capacity 7.50 Tonne Single girder. Each 27-297 12000000
Same as Item 27-296, but Capacity 10.00 Tonne Double Each 27-298 13554910
girder.
Same as Item 27-296, but Capacity 15.00 Tonne Double Each 27-299 16400000
girder.
Same as Item 27-296, but Capacity 20.00 Tonne Double Each 27-300 18600000
girder.
Same as Item 27-296, but Capacity 25.00 Tonne Double Each 27-301 20060000
girder.
Same as Item 27-296, but Capacity 30.00 Tonne Double Each 27-302 27900000
girder.
Same as Item 27-296, but Capacity 35.00 Tonne Double Each 27-303 28800000
girder.
Same as Item 27-296, but Capacity 5.00 Tonne single girder, Each 27-304 11725000
span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 7.50 Tonne single girder, Each 27-305 12500000
span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 10.00 Tonne double Each 27-306 14154910
girder, span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 15.00 Tonne double Each 27-307 17400000
girder, span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 20.00 Tonne double Each 27-308 19800000
girder, span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 25.00 Tonne double, span Each 27-309 21600000
20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 30.00 Tonne double Each 27-310 29800000
girder, span 20.00 metre, bay length 15.20 metre.
Same as Item 27-304, but Capacity 35.00 Tonne double Each 27-311 30800000
girder, span 20.00 metre, bay length 15.20 metre.
Same as Item 27-312, but 15 Tonne Capacity, Span14 Metre, Each 27-314 54093531
bay length 20.42 metre, lift of height 9.1 metre, double
girder.
Standard Manual Cranes
Supply, fixing, Testing and Commissioning of all motion Each 27-315 3600000
manual control crane, span 16 metre, bay length 30 metre,
Height of lift 4.3 metre, capacity 3 Tonne single girder,
complete in all respect as per drawings and specification.
Same as Item 27-315, but 3 Tonne capacity, span 12 Metre, Each 27-316 3227566
bay length 20 metre, lift of height 4.3 metre.
Same as Item 27-315, but 3 Tonne capacity, span 9 Metre, Each 27-317 2945318
bay length 12 metre, lift of height 4.3 metre.
Same as Item 27-315, but 3 Tonne capacity, span 14 Metre, Each 27-318 2900000
bay length 16 metre, lift of height 4.5 metre.
Manual Cranes Ex Class
Supply, fixing, Testing and Commissioning of All motion Each 27-319 6200000
manual control Ex class crane, span 4 metre, bay length 24
metre, height of lift 3.0 metre, capacity 3 Tonne single girder,
complete in all respect as per drawings and specification.
Generator Set
Supply, installation, testing and commissioning of Diesel Each 27-320 1467270
Engine Prime rating Generator in accordance with ISO-3046,
ISO-9001:2015, BS-5514, DIN-6271, AS-2789, 2014/3/EU
electromagnetic compatibility and 2000/14/EC, noise
emission for outdoor use. Engine and alternator mounted on
robust skid frame including fuel tank, control panel, diesel
engine four stroke, water cooled 1500 RPM, built in battery
charger, batteries and brushless self-excited alternator,
400/230V, 3 phase and NL, 50 Hz, power factor 0.8, with ATS
panels but without canopy, (CBU) complete assembled,
integrated/manufactured in EU, UK & USA 09 KVA.
Add to item 27-377 to 27-380 or 27-386, if removal only. Each 27-389 4500
Add to item 27-381 to 27-384 or 27-387, if removal only. Each 27-390 7500
PCC solid block (0.300 x 0.200 x 0.150 Mtr) Load Bearing. Each 28-179 50
PCC solid block (0.300 x 0.200 x 0.150 Mtr) Non Load Each 28-180 44
Bearing.
PCC hollow block (0.400 x 0.200 x 0.150 Mtr) Non Load Each 28-181 59
Bearing.
Pedestal any Colour. Each 28-182 1660
Pillar cock, CP. Each 28-183 1351
Plastic Bath Cabinet, 450 mm x 450 mm x 100 mm. Each 28-184 2767
Plastic Connection, 15 mm-Plastic union both end. Each 28-185 141
Plastic connection, 20 mm dia Brass. Each 28-186 222
Plastic Emulsion. Lit 28-187 299
Plastic float valve, 15 mm dia. Each 28-188 252
Plastic shelf. Each 28-189 503
Plastic stud with reflector, 10 cm x 20 cm x 2 cm (Flush type). Each 28-190 550
Sink Stainless Steel with Double Drainage Board and Double Each 28-238 9861
Bowl exceeding 6000 Sqcm upto 9300 Sqcm.
Sink waste coupling. Each 28-239 252
Sliding Bolt (Brass), 300 mm long. Each 28-240 1207
Sliding Bolt (Brass), 450 mm long. Each 28-241 1590
Sliding Bolt (CP), 300 mm long. Each 28-242 322
Sliding Bolt (CP), 450 mm long. Each 28-243 584
Soap tray. Each 28-244 312
1st Class Soft wood, Deodar. Cum 28-245 141500
Soil Aggregates, 40 mm to 50 mm. Cum 28-246 1324
Speed Breaker plastic 350 mm x 500 mm x 50 mm with Mtr 28-247 13500
reflectorized metal.
Speed Breaker plastic 350 mm x 500 mm x 50 mm with Mtr 28-248 6500
reflectorized PPM rubber.
Speed Breaker plastic 350 mm x 500 mm x 50 mm. Mtr 28-249 8500
Steel Chowkat, 16 gauge. Kg 28-250 150
Steel Chowkat, 18 gauge. Kg 28-251 146
Steel corrugated galvanized sheeting, 20 gauge of any Tonne 28-252 146900
standard size.
Steel corrugated galvanized sheeting, 22 gauge of any Tonne 28-253 151844
standard size.
Steel corrugated galvanized sheeting, 24 gauge of any Tonne 28-254 152210
standard size.
Steel Galvanised Sheets, 18 gauge. Sqm 28-255 1513
Steel Galvanised Sheets, 20 gauge. Sqm 28-256 1228
Steel Galvanised Sheets, 22 gauge. Sqm 28-257 1028
Steel Galvanised Sheets, 24 gauge in walls floor ceiling. Sqm 28-258 835
Stone dust (Khaka). Cum 28-259 1103
Stones, Random Rubble, Roughly dressed. Cum 28-260 1059
Synthetic vinyl (PVC) flexible membrane, 0.25 mm thick. Sqm 28-261 258
Synthetic vinyl (PVC) flexible membrane, 0.5 mm thick. Sqm 28-262 516
Synthetic vinyl (PVC) flexible membrane, 1.0 mm thick. Sqm 28-263 1046
Synthetic vinyl (PVC) flexible membrane, 2.0 mm thick. Sqm 28-264 1821
Tee Stop cock CP. Each 28-265 684
Termite Proofing Chemical. Ltr 28-266 4800
Thermopore Tiles, 600 mm x 600 mm x 20 mm. Sqm 28-267 323
Tiles (Glazed / Non-skid / Matt), Standard quality not Sqm 28-268 1890
exceeding 1600 sq cm
Tiles (Glazed / Non-skid / Matt), Deluxe quality exceeding Sqm 28-269 2529
1600 sq cm but not 3700 sq cm.
Tiles (Glazed / Non-skid / Matt), Premium quality exceeding Sqm 28-270 2860
3700 sq cm.
Tiles Granite 20 mm thick, Standard Quality. Sqm 28-271 2727
Tiles Granite 20 mm thick, Deluxe Quality. Sqm 28-272 5023
Tiles Granite 20 mm thick, Premium Quality. Sqm 28-273 7727
Tiles Marble 13 mm thick, Standard Quality. Sqm 28-274 630
Tiles Marble 20 mm thick, Standard Quality. Sqm 28-275 2338
Tiles Marble 13 mm thick, Deluxe Quality. Sqm 28-276 1236
Tiles Marble 20 mm thick, Deluxe Quality. Sqm 28-277 4876
Tiles Marble 13 mm thick, Premium Quality. Sqm 28-278 5005
Tiles Marble 20 mm thick, Premium Quality. Sqm 28-279 12110
Tiles Mosaic 300 x 300 x 25 mm of ordinary cement. Each 28-280 65
Tiles Mosaic 300 x 300 x 25 mm of white cement. Each 28-281 76
Toilet paper holder, Plastic. Each 28-282 497
Toilet shower, 15 mm dia. Each 28-283 1107
Torch Bonding Bituminous membrane, 3 mm thick. Sqm 28-284 851
Torch Bonding Bituminous membrane, 4 mm thick. Sqm 28-285 1069
Towel Rail CP, Double rod. Each 28-286 1107
Towel Rail CP, Single rod. Each 28-287 996
Teak Ply, 3 mm thick. Sqm 28-288 410
U bolts, 10 mm dia. C.No 28-289 28
uPVC Door Handle. Each 28-290 805
uPVC Door Hinges 2D. Each 28-291 895
uPVC Door Lock. Each 28-292 4025
uPVC soil and waste pipe, 200 mm. Meter 28-293 1211
uPVC soil and waste pipe, 300 mm. Meter 28-294 1868
uPVC P Trap, 75 mm. Each 28-295 243
uPVC P Trap, 100 mm. Each 28-296 366
uPVC Floor Trap, 100 mm. Each 28-297 515
Urinal Basin. Each 28-298 4126
Vanity Bowel. Each 28-299 4528
Venetian Blind, Horizontal, having metallic, plastic strip upto Sft 28-300 166
25 mm width.
Venetian Blind, Vertical, having fabric strip upto 90 mm Sft 28-301 282
width.
Venetian Blind, Vertical having fabric strip width exceeding 90 Sft 28-302 312
mm width upto 127 mm.
Venation Blind,Horizontal, having wooden strip. Sft 28-303 332
W.C Asiatic Pattern with Plastic Flushing tank. Each 28-304 4254
W.C Closet Pan European pattern. Each 28-305 2516
W.C Closet with Cistern any Colour with Seat Cover (non- Each 28-306 6591
coupled).
Wall Paper. Sqm 28-307 1000
Wall Shower, Standard Quality. Each 28-308 11180
Wall Shower, Deluxe Quality. Each 28-309 15460
Wall Shower, Premium Quality. Each 28-310 21822
Wash Hand Basin (WHB), Standard Quality. Each 28-311 5680
Wash Hand Basin (WHB), Deluxe Quality. Each 28-312 7500
Wash Hand Basin (WHB), Premium Quality. Each 28-313 9985
Wash Hand Basin (WHB), Glazed. Each 28-314 2666
Waste coupling. Each 28-315 252
Waste Pipe PVC. Each 28-316 100
Water bound macadam. Cum 28-317 1324
Water Closet (WC), European pattern (coupled), Standard Each 28-318 10500
Quality.
Water Closet (WC), European pattern (coupled), Deluxe Each 28-319 13150
Quality.
Water Closet (WC), European pattern (coupled), Premium Each 28-320 18190
Quality.
Water Proofing textile geo membrane, 0.25 mm thick. Sqm 28-321 402
Water stopper PVC, 225 mm wide, 5 mm thick. Mtr 28-322 656
Water stopper PVC, 225 mm wide, 8 mm thick. Mtr 28-323 1148
Water stopper PVC, 250 mm wide, 10 mm thick. Mtr 28-324 1641
Water stopper PVC, 250 mm wide, 12 mm thick. Mtr 28-325 1805
WC wall mounted. Each 28-326 12542
Wire Plain galvanized, 8 SWG. Metre 28-327 20
Wire Plain galvanized, 12 SWG. Metre 28-328 12
Wire Plain galvanized, 14 SWG. Metre 28-329 8
Wire Plain galvanized, 16 SWG. Metre 28-330 7
Wire Gauze 9x9 mesh, 24 Gauge. Sqm 28-331 660
Wire Gauze Aluminium16 x 16 mesh, 26 Gauge. Sqm 28-332 552
Wire Gauze iron Tinned 9 x 9 mesh, 22 Gauge. Sqm 28-333 747
Wire Gauze, Mosquito Proof, 16 x 16 mesh 26 gauge. Sqm 28-334 811
Wire Gauze, Mosquito Proof, 18 x 18 mesh 28 gauge. Sqm 28-335 171
Wire mattress, GI 100 mm x 100 mm. Sqm 28-336 800
Wire mattress, GI 150 mm x 150 mm. Sqm 28-337 650
Wire Netting Galvanised, 25 mm mesh, 14 SWG. Sqm 28-338 454
Wire Netting Galvanised, 25 mm x 25 mm mesh, 12 SWG. Sqm 28-339 639