You are on page 1of 3

CEDES Instruction Manual GLS 126 NT-MV Instruction Manual GLS 126 NT-MV CEDES

Drawings Technical Data GLS 126 NT-MV

Supply voltage (USP) 12 - 60 VDC


Max. ripple voltage (USP) ± 0.25 x (USP)
Current consumtion max. 30 mA (without load)
Holder (optional)
Input capacitive load 47 nF
Cable Outlet Output saturation < 0.5 V
voltage (USP) (IL = 100 mA)
Optical Axis Optical Axis - Light beam interrupted
LED LED PNP
LED Output
short circuit proof
Capacitive load max. 10 µF
Response time max. 1ms
Max. output current 200 mA

Mounting Holes for PT-Screws


GLS 126 NT-MV housing

Block circuit diagram

LED

USP (brown)

Out (black)

We
50 k Ω
CEDES AG, CH-7302 Landquart / Switzerland
declare conformity in sole responsibility that the optoelectronic sensors
GLS 126 NT-MV 0V (blue)
according to the following Council Directives

EU EMC 89 / 336 / EWG


modified 92 / 31 / EWG
Standards and Specifications

EN 12015, 12016 Electromagnetic compatibility - product family standard for elevators, escalators
and passenger conveyors - emission / immunity Description Light beam Output LED
Test report CEDES, EMV_GLS126 NT-MV
Use: not interrupted + (USP) on
The bringing into service is only permitted after thorough checks are carried out to ensure that the machinery or GLS 126 NT-MV, NC
plant into which these products are built, meets the requirements of the regulations and directives relevant to that interrupted 0V off
machinery or plant.

Landquart, 2006-02-28 not interrupted 0V on


Peter Meier GLS 126 NT-MV, NO
Quality Assurance interrupted + (USP) off
18th January 2008 / Part No. 104 433e Version 1.1
CEDES Instruction Manual GLS 126 NT / NC-HCL Instruction Manual GLS 126 NT / NC-HCL CEDES
Drawings Technical Data GLS 126 NT / NC-HCL

Supply voltage (USP) 10 - 30 VDC


Max. ripple voltage (USP) ± 0.25 x (USP)

Holder (optional) Current consumtion max. 30 mA (without load)

Input capacitive load 450 nF


Cable Outlet
Output saturation < 1.5 V
Optical Axis Optical Axis
voltage (USP) (IL = 100 mA)
- Light beam interrupted
LED LED LED NPN
Output
short circuit proof
Capacitive load max. 1000 µF
Response time max. 1ms
Max. output current 200 mA

GLS 126 NT / NC-HCL housing


Mounting Holes for PT-Screws

Block circuit diagram


LED

U SP (brown)

10 kΩ
We
Out (black)
CEDES AG, CH-7302 Landquart / Switzerland
declare conformity in sole responsibility that the optoelectronic sensors
GLS 126 NT / NC-HCL
according to the following Council Directives 0V (blue)
EU EMC 89 / 336 / EWG
modified 92 / 31 / EWG
Standards and Specifications

EN 12015, 12016 Electromagnetic compatibility - product family standard for elevators, escalators
and passenger conveyors - emission / immunity
Test report CEDES, EMV_GLS126NT_HCL_040512.doc
Use:
The bringing into service is only permitted after thorough checks are carried out to ensure that the machinery or Description Light beam Output LED
plant into which these products are built, meets the requirements of the regulations and directives relevant to that
machinery or plant. + 24 V (USP)
not interrupted on
Landquart, 2004-11-24 GLS 126 NT/NC-HCL
Beat De Coi interrupted 0V off
Quality Assurance
27th March 2007 / Part. No: 104 200e Version 0.2
CEDES Instruction Manual GLS 126 NT Instruction Manual GLS 126 NT CEDES
Drawings Technical Data GLS 126 NT

Supply voltage (USP) 10 - 30 VDC


Max. ripple voltage (USP) ± 0.25 x (USP)
Holder (optional)
Current consumtion max. 40 mA (without load)
Input capacitive load 450 nF
Cable Outlet
Output saturation < 0,5 V
Optical Axis Optical Axis voltage NPN (IL=100 mA)

LED LED
Output saturation < 2,0 V
LED
voltage PNP (IL=100 mA)
NPN / PNP
Output
short circuit proof
Capacitive load max. 100 nF
Rise / fall time max. 1ms
Max. output current 200 mA GLS 126 NT housing
Mounting Holes for PT-Screws

Block circuit diagram

LED
USP (brown)

Out (black)

We
CEDES AG, CH-7302 Landquart / Switzerland
declare conformity in sole responsibility that the optoelectronic sensors 0V (blue)
GLS 126 NT
according to the following Council Directives

EU EMC 89 / 336 / EWG


modified 92 / 31 / EWG
Standards and Specifications
EN 12015 EME-product family standard for lifts, escalators, passenger conveyors Description Light beam Output LED
EN 12016 EMI-product family standard for lifts, escalators, passenger conveyors
Test report CEDES, EMV_GLS126NT_030729.DOC not interrupted + 24 V (USP) on
Use:
GLS 126 NT-NC
The bringing into service is only permitted after thorough checks are carried out to ensure that the machinery or interrupted 0V off
plant into which these products are built, meets the requirements of the regulations and directives relevant to that
machinery or plant. not interrupted 0V on
Landquart, 2004-11-09
GLS 126 NT-NO
Beat De Coi interrupted + 24 V (USP) off
Quality Assurance
27th March 2007 / Part. No: 104 089e Version 0.1