You are on page 1of 3

Title: Load Calculation

Wall Load
Thickness Density Opening Fl. Height Beam Depth Height
Type of Wall
m kN/m3 % m m m
External Wall with plaster 0.23 19.2 2.845 0.4064 2.4386
External Wall with plaster 0.23 19.2 75% 2.845 0.4064 2.4386
Partition Wall with plaster 0.115 19.2 2.845 0.4064 2.4386
Partition Wall with plaster 0.115 19.2 75% 2.845 0.4064 2.4386
Parapet Wall with plaster 0.23 19.2 1.0668
Parapet Wall with plaster 0.115 19.2 1.0668

Live Load
Rooms 3 kN/m2
Kitchen 2 kN/m2
Toilet 2 kN/m2
Balcony 3 kN/m2
Terrace 1.5 kN/m2
Corridor 3 kN/m2
Partition Wall 2 kN/m2
Partition Wall 2.2 kN/m2
Stairs 3 kN/m2

Floor Finish
Rooms
Thickness Density W
Materials
mm kN/m3 kN/m2
Screeding 40 20.4 0.816
Marble 25 26 0.65
Total 1.466

Toilet
Thickness Density W
Materials
mm kN/m 3
kN/m2
Brick Bats Filling 150 19.2 2.88
Screeding 25 20.4 0.50875
Tile 8 26 0.208
Total 3.6
41.452992
10.90868211
W
kN/m
12.14
9.10
6.75
5.07
5.31
2.95