Troubles of Fresh Water Generator
Troubles of Fresh Water Generator
Vocabulary
Reading
0.05 MPa___________________________________________________________
0.08 MPa___________________________________________________________
50_________________________________________________________________
Low Rate of Distillate Generation
The heating tubes or the condenser piping are dirty inside and need cleaning.
Hot water temperature and/or flow rate is low and needs to be increased by the operator.
Dropping of Evaporation Temperature
The temperature or flow rate of hot water is low and needs to be increased to the specified level
The vacuum in the evaporator dropped
There is an air leak in the system which should be repaired and then tested at 0.05 MPa to make
sure regular operation has been restored.
Malfunctioning of Water Ejector
The nozzle of the ejector has closed partially or fully and needs to be cleaned
The diffuser is worn out and must be replaced.
The nozzle is worn out and must be replaced.
The pressure at the outlet of the ejector is at 0.08 MPa or higher.
The ejector outlet piping may be clogged and needs to be checked and corrected. The valve
opening of the overboard discharge valve needs to be checked and repaired.
The pressure at the outlet of the ejector is negative; the overboard discharge valve should be
closed up to a certain degree.
The distillate is present in the Sight Glass
This may indicate failure of the Distillate pump. It should be repaired.
The outlet valve of the Distillate pump is in the closed position and must be opened.
The outlet piping is clogged and must be cleaned
The pump is drawing in air, and the mechanical seal needs to be replaced.
High Salinity of the Distillate
The rate of generation of the distillate is too high and needs to be decreased by lowering the hot
water flow rate.
The temperature of evaporation is low (50 degrees or such). The vacuum adjusts valve needs to
be closed to the position when evaporating temperature increases.
The FWG uses dirty feed water and needs to be stopped.
The reading of the salinity indicator is faulty and must be tested.
The piping of the condenser is damaged and needs to be plugged inappropriately.
Low Feed Water Rate
The opening of the feed water adjusts valve is not sufficient and needs to be adjusted.
The feed water orifice may be clogged, and its surface needs to be cleaned.
High Feed Water Rate
The feed water adjusts valve has a very large opening and needs to be closed sufficiently.
The feed water orifice has been worn and needs to be replaced.
1 2 3 4 5 6 7 8
7 Answer the questions
1. What parts of FWG can be clogged? What a ship engineer should do in this case?
2. What parts of FWG can be worn out? What should be done with worn parts?
3. What trouble can be caused with insufficient quality of feed water? What should
be done in this case? Why?
4. What does the distillate on the sight glass indicate? How to fix this trouble?
5. How to regulate feed water rate? Why is it necessary?
6. What malfunctions can be caused with wrong pressure?
Speaking
8 In groups, comment on real life situations. Define causes and measures to be taken.
Group A. Fresh water generator doesn’t produce the amount of fresh water stated by the
manufacturer.
Group B. Water injector doesn’t work properly, its working parameters differ greatly from the
ones stated in the manual.
Group C. According to the salinometer indicator fresh water cannot be used for any domestic or
auxiliary needs as salt content is too high.