This document provides standards and guidelines for building accessibility and fire safety, including requirements for seating, aisles, wheelchairs, entrances and exits, stairs, ramps, handrails, and doors. It references several codes and laws in the Philippines related to building accessibility, including the National Building Code, Accessibility Law, and Fire Code. The document outlines specific dimensional requirements for various building elements to ensure accessibility and safety compliance.
Original Description:
A review of a Related Laws in Designing A sports Facility
Original Title
A review of a Related Laws in Designing A sports Facility
This document provides standards and guidelines for building accessibility and fire safety, including requirements for seating, aisles, wheelchairs, entrances and exits, stairs, ramps, handrails, and doors. It references several codes and laws in the Philippines related to building accessibility, including the National Building Code, Accessibility Law, and Fire Code. The document outlines specific dimensional requirements for various building elements to ensure accessibility and safety compliance.
This document provides standards and guidelines for building accessibility and fire safety, including requirements for seating, aisles, wheelchairs, entrances and exits, stairs, ramps, handrails, and doors. It references several codes and laws in the Philippines related to building accessibility, including the National Building Code, Accessibility Law, and Fire Code. The document outlines specific dimensional requirements for various building elements to ensure accessibility and safety compliance.
STANDARD PD 1096 BP 344 RA 9514 Fire Code Conclusion
National Accessibility Law of the Philippines
Building Code Occupant Load Concentrate d: 0.65 sqm/perso n Lessconcentrate d: 1.4 sqm/person Seats Rows of Seats Rows of Seats PD 1096 (Back-toBack): (Back-toBack): Minimum 840mm Seat 850mm Seats distance from Width: 450mm Between Aisles: another seat Spacing of Seats Max:14 Seats behind it: 300mm (Backto-Back): without arms: RA 9514 Rows of 850mm Minimum 0.6m/perso n Seats (Back to- distance from Back): 850mm another seat Seats Between behind it: 300mm Aisles: Max:14 Seats without arms: 0.6m/person Aisles Min width serving PD 1096 Min both sides: 1.00m width serving Min width serving both sides: 1.00m one side: 1.00m Min width serving one side: 1.00m Wheelchairs Length: 1.10m- BP 344 Length: 1.30m 1.10m-1.30m Width: 0.60m Width: 0.60m Turning Diameter: Turning Diameter: 1.50m Reach of 1.50m Reach of persons confined persons confined to wheelchairs to wheelchairs above floor: above floor: 0.70m-1.20m Leg 0.70m-1.20m Leg Space Clearance Space Clearance Under Tables: Under Tables: 0.70m Wheelchair 0.70m Wheelchair Seating: 51-300 Seating: 51-300 seating capacity: 4 seating capacity: 4 Disabled seats Regular bus: 5 BP 344 Regular Jeepneys: 2 bus: 5 Jeepneys: 2 Entrance/Exits Occupant load of Entrances with Min. Width of any PD 1096 Occupant 300: Min: 3 exits vestibules shall be means of egress: load of 300: Min: Min dimension: provided with a 915mm For any 3 exits Min 0.90mx2.00m level area with at storey, mezzanine, dimension: Clear Width: Min: least a 1.80m balcony, etc.: 0- 0.90mx2.00m 900mm Max Exit depth and a 499 occupant Clear Width: Min: Door Leaf: 1.20m 1.50m width load: 2 exits Travel 900mm Max Exit Distance to Exits: Distance to exit: Door Leaf: 1.20m Max: 45m 15m Headroom: Distance to Exits: (without sprinkler 2.00m Max: 45m system) Max: 60m (without sprinkler (with sprinkler system) Max: 60m system) Min (with sprinkler thread for Ent. system) Min /ext. step: 300mm thread for Ent. Max no. of steps /ext. step: 300mm (Ent/ext.): 2 Max no. of steps (Ent/ext.): 2 BP 344 Entrances with vestibules shall be provided with a level area with atleast a 1.80m depth and a 1.50m width Stairs Min width: Max. Riser: Max. Height of PD 1096 Min 750mm Max rise: 150mm Min Riser: 205mm width: 750mm 200mm Min run: Tread: 300mm Tread Depth: Min run: 200mm 200mm Occupant 230mm Min. Occupant Load Load more than Headroom: more than 50: 50: Stairway 2000mm Max. Stairway Width:1.10m Height between Width:1.10m Maximum vertical Landings: Maximum vertical distance between 3660mm Riser: distance between landings: 3.60m 100- 180mm landings: 3.60m Maximum Maximum dimension of dimension of landing: 1.20m landing: 1.20m BP 344 Max. Riser: 150mm Handrails and Min height: Height: 0.90m and 760mm865mm BP 344 Height: Grab Bars 800mm Maximum 0.70m Handrail from upper 0.90m and 0.70m height: 900mm Extension: surface of tread Handrail 300mm Handrail Extension: Grip: 30mm- 300mm Handrail 50mm Ramp with Grip: 30mm- rise greater than 50mm Ramp with 0.20m: 1.80m rise greater than from foot to ramp 0.20m: 1.80m from foot to ramp Ramps Entrance/Exit Max. Ramp Max. Slope: 1:12 BP 344 Max. Maximum slope: Length: 6m Ramp Max, Rise for a Ramp Length: 6m 1:10 Ramp Landing for Landing for 1:12 single ramp: 1:12 gradient: gradient: 1.50m 760mm 1.50m Level area at top Minimum width Level area at top and bot. of ramp: clear: 1120 mm and bot. of ramp: 1.80m Curb on 1.80m Curb on both sides of both sides of ramp: 0.10m ramp: 0.10m Doors Min width: Min. Clear Width: Clear Opening: PD 1096 Min 900mm Min 0.80m 90 deg. 710mm1220mm width: 900mm height: 2.00m At Opening Max. Threshold Min height: 2.00m least 90 deg. Height: 13mm At least 90 deg. Opening Max. Opening Max. Door Leaf: 1.20m Door Leaf: 1.20m Window Rooms not to PD 1096 Rooms Openings provide Artificial not to provide Ventilation: 10% Artificial Toilet: 1/20 not Ventilation: 10% less than 240mm2 Toilet: 1/20 not Min. Clearance: less than 240mm2 750mm Min. Clearance: Dimensions 750mm Intended to be Dimensions Used as Intended to be Emergency Exits: Used as 820mmx1000 mm Emergency Exits: 820mmx1000 mm Building Height 3m RROW: 2- PD 1096 3m storey/6m 4-5m RROW: 2- RROW: 2.5- storey/6m 4-5m storey/7.5m 6-7 RROW: 2.5- RROW: 3- storey/7.5m 6-7 storey/9m RROW: 3- storey/9m Ceiling Height One-Storey: PD 1096 One- 2.40m Two- Storey: 2.40m Storey: Ground Two-Storey: Floor: 2.70m Ground Floor: Second Floor: 2.70m 2.40m Mezzanine Second Floor: Floor: 1.80m 2.40m Mezzanine Floor: 1.80m Rooms for Human 6 sqm with at PD 1096 6 sqm Habitations least dimension of with at least 2.00m dimension of 2.00m Kitchen 3sqm with at least PD 1096 3sqm dimension of with at least 1.50m dimension of 1.50m Toilets and Baths, 1.20 sqm with at Dimension:1. PD 1096 1.20 sqm Restrooms least dimension of 70x1.80m Min. of with at least 0.90m PWD Toilet Stalls: dimension of 20 wc or less: 1 0.90m BP 344 More than 20 wc: Dimension:1. 2 Max Height for 70x1.80m Min. of Water Closet: PWD Toilet Stalls: 0.45m Max. 20 wc or less: 1 Heighflush More than 20 wc: Control: 1.20m 2 Max Height for Max. Height Water Closet: Lavatories: 0.80m 0.45m Max. Max. Height Heighflush Urinal: 0.48m Control: 1.20m Max. Height Lavatories: 0.80m Max. Height Urinal: 0.48m Workstations 12.00 cu.m air Min. Width PD 1096 12.00 space/person 1 Access Aisle: cu.m air sqm floor 920mm space/person 1 area/person sqm floor area/person Restaurants Minimum BP 344 Circulation Path: Minimum 1.20m Circulation Path: Accessible Route 1.20m Accessible Clear Width: Route Clear 900mm Width: 900mm Sidewalks and Width: 1.20m Min. Width: BP 344 Min. Walkways 1.20m Walkway Width: 1.20m Gradient: 1:20 or Walkway 5% Gradient: 1:20 or 5% Parking Perpendicular and Width: PD 1096 Diagonal: 3.70mx5.00 m Perpendicular and 2.5mx5m Average Diagonal: Car Parallel: 2.5mx5m Average 2.15mx6m Car Parallel: Truck/Bus: 2.15mx6m 3.6mx12m Truck/Bus: Jeepney: 3mx9m 3.6mx12m Jeepney: 3mx9m BP 344 Width: 3.70mx5.00m Dropped Curbs Min Width: 0.90m BP 344 Min Min Towards Width: 0.90m Min Adjoining Towards Adjoining Curbs/Ramps : Curbs/Ramps : 1:12 gradient 1:12 gradient Max. Lowest Max. Lowest Point: 25mm Point: 25mm CornerThrough Percentage of PD 1096 Lot Open Space: 5% Percentage of Open Space: 5% On nonarcaded Max. Height: 1.40- BP 344 Max. RROW: Signs shall 1.60m Min. Height: 1.40- not project more Embossed Signs: 1.60m Min. than 1.20m On 1mm 600mmx600 Embossed Signs: Arcaded RROW: mm Pole 1mm 600mmx600 Signs shall not Mounted mm Pole project more than Parking Signage Mounted Parking 0.60m Building Pavement Sign Signage Pavement abutting RROW Square: 1.00m- Sign Square: without 1.50m from FFL. 1.00m-1.50m sidewalks: Signs from FFL. shall not project more than 0.30m Minimum vertical Clearance: Non- Aracaded RROW: 3.00m Arcaded RROW: 5.00m Signage Minimum BP 344 Minimum Circulation Path: Circulation Path: 1.20m Accessible 1.20m Accessible Route Clear Route Clear Width: 900mm Width: 900mm Floor Area Allowable Maximum Total Gross Floor Area (TGFA) General. The Allowable Maximum Total Gross Floor Area (TGFA) of any proposed building shall only be as allowed under this Rule TGFA Limitation “ In Table Vii.6.1. the percentages indicated in the 3rd through 8th columns are the percentages of the Total Lot Area (TLA) that may be used to determine the Allowable Maximum TGFA while the multiplier numbers 3, 5, 12, 18 and 30 represent the number of storeys. The Allowable Maximum TGFA should not exceed the Allowable Maximum Volume of Building (AMVB). If exceeded, the Allowable Maximum TGFA must be adjusted since the AMVB must always prevail. See Table 1.3
Setbacks Setbacks – vacant
space bet the bldg. & lot lines not < 2.00m in width See Table 1.1