OPERATING MANUAL
PART 1: USER
PART 2: SERVICE AND MAINTENANCE
LV30500
ORIGINAL INSTRUCTION
80.021.169 Revision 01 December 2019
BioAir S.p.A.
Head offices and Manufacturing Plant: Via Lombardia, 12 - 27010 Siziano (PV) Italy
www.bioair.it - info@bioair.it
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
Dear Customer!
Thank you very much for purchasing a BioAir product. You have just acquired an high quality
cabinet and we require you take a few minutes to read this operating and maintenance
manual in order to become acquainted with your instrument and use it at the best of its
performances.
We are confident that you have purchased an excellent product and that you will be
completely satisfied with it. Should you have any enquiry, pls do not hesitate to contact your
local Distributor or, directly us at BioAir, we will be delighted to assist you.
If you require any further information or explanation of the information contained in this manual, and
for any request relevant to:
service
spare parts
technical data
contact:
+ 39 0382 610924
service@bioair.it
sat@bioair.it
BioAir S.p.A.
Via Lombardia, 12
27010 Siziano (PV)
+ 39 0382 6672.1
+ 39 0382 610924
info@bioair.it
and check the manufacturer’s label for the code and the serial number of the cabinet.
Page 3 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
LABELLING
On every cabinet is placed a label as per the below example of Pic. 1with the main technical data of the
cabinet.
Logo
Name of manufacturer
Address of manufacturer
CE Mark (for European Market only)
Model
Code
Voltage, Frequency, Power
Warning (3)
Serial number
Year of manufacturing
Standard conformity (1)
Competent Body Mark (2)
Factory use code (4)
Pic. 1
MEANING OF SYMBOLS
GENERAL WARNING.
PROVISIONS SIGN
Page 4 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
GLOSSARY
Apf: Aperture protection factor.
DOP: Dispersed Oil Particle.
EMC: Electromagnetic Compatibility.
EMI: Electromagnetic Interference.
Exh: Exhaust air flow.
HEPA: High Efficiency Particulate Air.
LAF: Laminar Air Flow.
MPPS: Most Penetrating Particle Size.
PELV: Protection by Extra-Low Voltage
UV-C: Ultraviolet radiation (range C - germicidal).
This manual is intended to explain the correct use of this vertical laminar flow cabinet with partial
recirculation, equipped with a front opening through which the operator can perform the manipulation
of the products in environment ISO 5 according to the standard EN 14644-1 .
It can be configured to PRODUCT/USER PROTECTION (default) or as ONLY PRODUCT PROTECTION.
Page 5 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
CONTENTS
LABELLING 4
MEANING OF SYMBOLS 4
GLOSSARY 5
PURPOSE AND USE OF THE MANUAL 5
PART 1: USER 9
1. ASSESSMENT OF RISKS 11
1.1. Misuse hazard. 11
1.2. UV-C radiations hazard. 12
1.3. UV-C radiations hazard. 12
1.4. Spread of fire from the equipment hazard. 13
1.5. Liberated gases and explosion hazard. 13
2. RULING STANDARDS AND DEFINITION 14
2.1 EC DECLARATION OF CONFORMITY 14
2.2 DEFINITION 14
3. INSTALLATION 15
3.1 CHOICE OF LOCATION 15
3.2 POSITIONING 15
3.3 CONNECTION TO THE MAINS 15
3.4 FINAL PROCEDURES 16
4. TECHNICAL DATA 17
4.1 SPECIFICATIONS 17
4.2 USE ENVIRONMENTAL CONDITIONS 17
4.3 TRANSPORT AND STORAGE CONDITIONS 17
4.4 PESO E DIMENSIONI 17
4.5 MATERIALS 18
4.6 PERFORMANCES 18
4.7 FILTERS DIMENSIONS AND FEATURES 18
4.8 MAIN OPTIONALS 18
5. OPERATING PRINCIPLE 19
6. CABINET DESCRIPTION 20
6.1 CONTROL BOX 20
6.2 WORKING SURFACE 21
6.3 UTILITIES 22
6.4 FRONT APERTURE 25
7. OPERATING INSTRUCTIONS 26
7.1 SWITCHING ON THE CABINET 26
7.2 LIGHT SWITCHING ON 26
7.3 LIGHT SWITCHING OFF 26
7.4 FAN SWITCHING ON 26
7.5 FAN SWITCHING OFF 26
7.6 UVC SOCKET ENABLING 27
7.7 UVC SOCKET DISABLING 27
7.8 SWITCHING OFF THE CABINET 27
7.9 GENERAL GUIDELINES 28
8. CLEANSING AND ROUTINE MAINTENANCE 29
8.1 CLEANSING 29
8.2 DECONTAMINATION 29
Page 6 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
Page 7 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
ORIGINAL INSTRUCTION
Page 8 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
PART 1:
USER
CABINETS
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
1. ASSESSMENT OF RISKS
AURA MINI is a vertical laminar flow cabinet with partial recirculation of the air.
NOTE: notwithstanding conformity with the standard referred, during operating of the cabinet
several residual risks remain and were assessed in order to take adequate measures to prevent the
following hazards arising from normal use and foreseeable misuse:
General
Misuse
Electric shock
UVC radiations
Spread of fire from the equipment
Liberated gases and explosion
The analysis were done as per EN 61010-1:2010, 7.3.3 and Annex J.
The residual risks have been assessed as per the following Tab. 1:
Tab. 1 – Risk Category
CATEGORY ASSESSMENT DESCRIPTION
1 Broadly This Category fulfils the requirement for tolerable risk.
acceptable.
2 As low as This Category does not automatically fulfil the requirement for
reasonably tolerable risk. If possible, reduce these risk to Category 1.
practicable.
If not possible, then the instructions should contain a description of
the risk so that the Responsible Body can take appropriate steps to
protect the safety of operators.
3 Intolerable. This category contains risks that are not tolerable risks.
NOTE: no residual risk of this cabinet belongs to Category 3.
Read the fallowing warnings before operating this cabinet.
Additional warnings shall be shown at the specific paragraphs.
PRECAUTIONS TO BE TAKEN:
The cabinet shall be used by authorized and adequately trained personnel
only.
Read carefully this manual before using the cabinet.
Keep this manual always and easily available.
DO NOT allow unauthorized people or general public to approach the cabinet.
Page 11 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
PRECAUTIONS TO BE TAKEN:
Prevent access to the place where the cabinet is installed to unauthorized
people or general public.
Authorize the use of this cabinet only to trained and informed personnel.
For long and continuous exposure is recommended an additional non-
transparent shielding.
Use UV-C lamps recommended by BIOAIR only.
PRECAUTIONS TO BE TAKEN:
Prevent access to the place where the cabinet is installed to unauthorized
people or general public.
Authorize the use of this cabinet only to trained and informed personnel.
In case of breakage of the glass during UV-C cycle protect immediately eyes
and skin and moreover:
keep people away from the cabinet;
switch immediately off UV-C function (or do not run it);
shut down the cabinet and prevent reusing; and
call servicing organization.
Page 12 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
PRECAUTIONS TO BE TAKEN:
DO NOT leave the cabinet with open flames.
Use this dedicated combustible gas line only to connect devices for use of
flame.
PRECAUTIONS TO BE TAKEN:
Use Bunsen burner only with flame control or piezoelectric ignition.
DO NOT connect combustible gas to vacuum/inert gas line.
DO NOT leave the cabinet with open flames.
Refer to all guidelines about the use of combustible gas.
Keep the gas tap closed when not in use.
Page 13 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
The Manufacturer:
BioAir S.p.A.
Via Lombardia, 12
27010 Siziano (PV)
IEC 61326-1:2012 Electrical equipment for measurement, control and laboratory use
EN 61326-1:2013 - EMC requirements - Part 1: General requirements.
2.2 DEFINITION
AURA MINI is a small size vertical laminar flow cabinet with partial recirculation of air designed to
provide a sterile environment in ISO 5 as per standard EN 14644-1 in which handle products and at
the same time (depending on configuration) protect the user from dust and fibres released during
the manipulation (default) or increase the protection of the product from external contamination.
The cabinet DO NOT provides at all any protection to the operator and the
environment from any potentially microbiologically hazardous product
handled therein.
WARNING! DO NOT handle potentially biohazard material inside this cabinet.
THE MANUFACTURER DECLINES ALL CRIMINAL AND CIVIL LIABILITY FOR FAILURES AND
DAMAGES DUE TO MISUSE, UNAUTHORIZED USE, TAMPERING OR ANY GENERAL USE OF
THE EQUIPMENT THAT IS NOT PERMITTED OR THAT DOES NOT COMPLY WITH THE
OPERATING INSTRUCTIONS CONTAINED IN THIS MANUAL.
Page 14 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
3. INSTALLATION
Install the cabinet in places with no air conditioning grilles and aisles, which
are not subject to air drafts and without frequent foot traffic.
3.2 POSITIONING
The cabinet should be fitted on a support stand (not supplied).
It is strongly advised the use of dedicated BIOAIR support stand which is
available in the optional accessories list.
WARNING!
Use of this accessory is under total responsibility of the customer.
The mains plug of the cord is the means for disconnection and it should be
visible and easy-accessible.
WARNING!
Page 15 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
Use of unsuitable mains supply cord compromises the safety of the cabinet.
WARNING!
Replacement of the mains supply cord (i.e. due to damaged cord or mains
plug not compatible with mains socket), should be done with an approved one
only, with same specifications as per Tab. 2.
The main fuses are replaceable from the outside, located in the
inlet appliance.
Pic. 3
A label close to the appliance inlet reports the values of the
fuses (Pic. 4).
Pic. 4
Page 16 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
4. TECHNICAL DATA
4.1 SPECIFICATIONS
Marks of conformity: |
Reference Standard: IEC 61010-1:2010 / EN 61010-1:2010
IEC 61326-1:2012 / EN 61236-1:2013
Electrical insulating/protection class [IEC 61140]: I
Mains supply voltage: 220-230 V~ 50/60 Hz
Main fuses: F5A H, 250V
Fluorescent lamp (W): 1x 24 T5 840
UV-C lamps (W): *
Required power line (W):
950
(3 A optional service socket included)
Absorbed power (W):
200
(fan and light on only)
Sustained impact maximum energy of the glass
4
[EN 61010-1, clause 8.2.2] (J):
Window glass UVC radiations retention (%): 98
Leaktightness index [EN 12469]: NA
Cleanability index [EN 12469]: NA
Sterilizability index [EN 12469]: NA
Combustible gas fixture max pressure (mbar): 20*
Inert fluids/vacuum fixture max pressure (bar): 4*
Electrical service socket max current (A): 3*
4.2 USE ENVIRONMENTAL CONDITIONS
Use: indoor
Altitude (m): up to 2000
Temperature (°C): from 10 to 35
80 for temperatures up to 31 °C,
Maximum relative humidity (%):
decreasing linearly to 50 at 40 °C
Max mains supply voltage fluctuations (%): up to ±10
Transient overvoltage category: II
Pollution degree: 2
4.3 TRANSPORT AND STORAGE CONDITIONS
Ambient temperature (°C): from -5 to 45
Relative humidity (%): up to 90
Atmospheric pressure (mbar): from 800 to 1060
4.4 PESO E DIMENSIONI
Weight (kg): 65
Overall L x D x H (mm): 850 x 590 x 820
Front aperture L x H (mm) : 735 x 180/300
Working space L x D x H (mm): 735 x 420 x 480
Safe work area L x D (mm): 575 x 260
Required operational space around (mm):
300 - 0 - 200 - 1000
[above - left – right - front]
Page 17 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
4.5 MATERIALS
cold rolled steel, stove enamel coated RAL
Main structure:
7035
Working surface and inner front wall: stainless steel AISI 304 - 2B finishing
Front window: tempered safety glass
4.6 PERFORMANCES
Laminar Air Flow mean velocity [EN 12469](m/s): 0,37 ÷ 0,43
Inflow Air Barrier mean velocity (m/s): 0,2 ±10%
3
Exhaust Air flow rate (m /h): 100 ±10%
Exhaust Air flow ratio (%): 25 ±10
Apf - Aperture Protection Factor [EN 12469]:
NA
(Retention efficiency at front aperture)
Working space air cleanliness class [EN 14644-1]: ISO 5
Illuminance [EN 12469] (lux): >750
Sound level [EN ISO 3744] (dB[A]): <65
Vibration [EN 12469] (mm RMS): NA
Max increase inside cabinet in temperature from the
<5
ambient [EN 12469] (°C):
Surface power density of UV-C lamp at 1 m (µW/cm2): *
UV-C spectral peak (nm): *
UV-C lamp average life (h): *
4.7 FILTERS DIMENSIONS AND FEATURES
LAF filter dimensions L x D x H (mm): 762 x 305 x 68
Filters efficiency class [EN 1822-1]: H14
Filters global MPPS efficiency [EN 1822-1](%): 99,995
MPPS diameter [EN1822-1](µm): 0,1 ÷ 0,3
NA = not applicable
* SEE DATASHEET OF ACCESSORY
** SOON NOT LONGER AVAILABLE
Page 18 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
5. OPERATING PRINCIPLE
The working area is ventilated by means of a unidirectional air flow recirculated (5), whose flow rate is
about 80% of the entire volume of air, while the remaining 20% is exhausted (6) from the cabinet.
The total air flow (100%) is provided by a fan (4) that blows air into a plenum from which a part of the
air, after HEPA filtration (1), is conveyed on the working surface (2) and the remainder is exhausted
outside the cabinet. The cabinet can be configured in two modes:
A) INFLOW MODE (DEFAULT)
PRODUCT/OPERATOR PROTECTION
This configuration (see Pic. 5), in addition to protection of the product also provides the protection of
the operator and the environment from dust and fibres released during processing of the products
inside the cabinet.
The exhaust of air occurs through an outlet
positioned on the roof. The exhausted air draws
an airflow (3) of equal volume directed towards
the inside through the front opening that forms a
protection barrier for the operator. This airflow
barrier (contaminated from the outside) is sucked
(7) together with the airflow to be recirculated
(contaminated by the product) to form 100% of
the airflow (contaminated) and to repeat the
cycle.
Pic. 5
B) OUTFLOW MODE
PRODUCT PROTECTION ONLY
This configuration (see Pic. 6) increases the product protection avoiding the entrance of external air
through the front opening, eliminating the protection of the operator.
The exhaust of air occurs through the front
opening. The exhausted air draws an airflow (3) of
equal volume directed towards the inside through
the opening on the roof. This inlet airflow
(contaminated from the outside) is sucked (4)
together with the airflow to be recirculated
(contaminated by the product) to form 100% of
the airflow (contaminated) and to repeat the cycle
(7) .
The amount of exhausted air (3) is replenished
with an equal amount of ambient air drawn in
through the opening on the roof (6), generating
into the front aperture an output air barrier.
Pic. 6
The front opening allows the operator to handle the product in both configurations.
Page 19 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
6. CABINET DESCRIPTION
Pic. 7
1. keypad (Pic. 8)
with power-on pilot light, alarm pilot
light (only factory optional), fan key,
light key and UVC key
Pic. 8
Page 20 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
UVC SOCKET ON
UVC YELLOW FIXED
FLUOR. LIGHT OFF
LIGHT ON
LIGHT NONE NA
UVC SOCKET OFF
Pic. 10
Pic. 11
Wrong positioning of the shelf may compromise the protection of the product.
WARNING!
Page 21 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
Pic. 12
6.3 UTILITIES
6.3.1 UVC light socket
This socket is located on the right side of the control box (Pic. 13)
and it is exclusively dedicated to activate BIOAIR UV-C light box.
Always enabled and interlocked with the fluorescent light.
To activate and deactivate it, follow instruction in 7.6 and 7.7
Pic. 13
Page 22 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
The taps together with the inlet hoses are placed across the glass sidewalls
(Errore. L'origine riferimento non è stata trovata.) and marked with suitable
labels (Pic. 14 and Pic. 16).
Combustible gas
Combustible gas line is controlled by a
ball valve tap in line, and it should be
connected according to local regulations.
The colour of the combustible gas tap
knob is yellow.
Pic. 14
Pic. 16
Cut off immediately gas supply in case of sudden lack of the vertical
airflow. This is a safety measure to prevent HEPA filter damage and
possible risk of fire.
WARNING!
NOTE 1: the provision of gas supply is not recommended. Flames from gas burners
interfere with laminar airflow within the cabinet and may compromise containment.
NOTE 2: where practicable, disposable loops or use of electrical loop sterilizers are
preferred to gas burners.
Page 23 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
The KIT should be connected to the dedicated UV-C socket (6.3.1) only and it should be
inserted in the cabinet closing the front access (Pic. 18).
Always enabled and interlocked with fluorescent light.
To turn it on, activate the timer of the KIT for the needed time and follow instruction in 7.6
To turn it off, follow instruction in 7.7
Turning on of the UV-C lamp is allowed only with the front window and panel closing the
front access fully closed.
Pic. 17 Pic. 18
Generally the effectiveness of UV-C lamp disinfection (wavelength 253,7 nm) depends on
exposure time and on the nature of microorganisms: special tables provide this information.
The disinfection must be performed after any work session.
The efficiency of this method depends on right exposure time of the cabinet work zone to
UV-C radiations.
NOTE: the fact that UV lamps are producing light is not directly related to their actual
neutralising power on DNA aerosols and microorganisms. Their actual efficiency may be
tested with proper devices.
On request it is possible to perform a test of efficiency of radiation emitted by the UV-C:
contact your BIOAIR distributor.
Page 24 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
The front window (like side walls) is made of tempered safety glass and it’s part of
enclosure being a protection against the UV-C radiations for the operator.
Moreover its position determines the inflow air barrier protection.
The breakage of the window compromises both the UV-C radiations protection and the air
barrier containment.
The front window is tilting and provided with self-support in the opening through the clutch
adjustment of the hinges.
The position of the window is not reported, but the window opening causes the turning off of
the UV-C lamp.
Pic. 19
It can be used in the following conditions:
cabinet off (protection against dust and external contamination);
cabinet with UV-C cycle activated (when paired with UV-C lamp).
Page 25 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
7. OPERATING INSTRUCTIONS
Turn on the cabinet by the main
7.1 SWITCHING ON THE CABINET switch located on the right side of the
cabinet (Pic. 7).
Page 26 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
NOTE: the key functions are stable and they are retained in case of shutdown of the cabinet or
blackout.
Page 27 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
Page 28 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
8.1 CLEANSING
8.2 DECONTAMINATION
Routine decontamination of the working area surfaces can be carried out by means of UV-C
radiation (optional).
The cabinet DO NOT provides at all any protection to the operator and the
environment from any potentially microbiologically hazardous product
handled therein.
WARNING! DO NOT handle potentially biohazard material inside this cabinet.
Page 29 of 47
80.021.169 r01 – December 2019
Aura MINI Operating Manual
Part 1: User
ORIGINAL INSTRUCTION
Page 30 of 47
80.021.169 r00 – December 2015
Aura MINI Operating Manual
Part 2: Service and maintenance
ORIGINAL INSTRUCTION
PART 2: SERVICE
AND
MAINTENANCE
All the operations described in this part of the manual should be performed
only by qualified technicians, properly trained authorized.
BIOAIR declines all the responsibility for damage resulting from non-compliance with these
provisions.
CABINETS
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
9. INSTALLATION
NOTE: the operations performed during installation should comply with the law provisions of the
safety at work.
The cabinet is shipped on a dedicated pallet with protective wrapping film and outer cardboard.
To handle and lift the cabinet is necessary to use a hydraulic fork-lift truck (trans-pallet) with lifting
forks up to a height of about 1 meter. The length of the forks should be at least 70 cm.
Remove the packing material only when the pallet is safely placed on the floor.
Disassemble the cardboard case and remove the polyethylene foil which covers the cabinet.
9.3 POSITIONING
The cabinet is to be placed on a stand or a bench: check that they are
adequate to support the weight of the cabinet.
The choice of stand or bench to use is under total responsibility of the
WARNING! customer.
It is strongly advised the use of dedicated BIOAIR support stand which is
available in the optional accessories list.
Lifting must be carried out with the aid of a mechanical means or by at least
2 persons (the cabinet net weight is 65 kg).
WARNING!
Page 33 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
The cabinet should be levelled. For the plane setting adjust the wheel screwing.
Page 34 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
The following tests from 0 to 9.6.5 should be carried out with the fan activated (see PART 1, 7.4).
NOTE 1: the tests below are optional and they are performed only at the specific request of the
customer.
9.6.1 HEPA filter integrity test:
Test: aerosol challenge method.
Standard accordance: EN 12469, annex D.
Instruments: cold aerosol generator and photometer or discrete particle counter.
Acceptability: particles penetration percentage should be less than 0,01% (photometer) or
less than 0,05% (discrete particle counter).
9.6.2 Air cleanliness test:
Test: air sampling of the working space.
Standard accordance: EN 14644-1.
Instruments: particle light scattering counter.
Acceptability: ISO 5 class or better.
9.6.3 Downflow air (LAF) velocity test:
Test: air velocity measurement in the working space (see 10.1.3).
Standard accordance: EN 12469
Instruments: hot wire anemometer.
Acceptability: average from 0,37 to 0,43 m/s.
9.6.4 Inflow air velocity test:
Test: exhaust air velocity measurement (see 10.1.1).
Standard accordance: EN 12469, annex G.
Instruments: 100 mm vane anemometer.
Acceptability: > 0,2 m/s.
9.6.5 Smoke pattern test:
Test: visualization of airflow patterns with smoke generator.
Standard accordance: EN 12469, Tab. 5.
9.6.6 Check of UV-C emissions efficiency:
Instruments: luxmeter/radiometer with UV-C probe.
9.6.7 Advised additional instruments:
digital multimeter capable of measuring true RMS AC voltage;
NOTE 2: the results of the laminar and exhaust air flow rate, should be consistent to the ones of the
factory test report (Quality Pass), where the performance data and the type of instruments are
indicated. The test procedures should be carried out in accordance with the conditions defined in the
factory test report.
Page 35 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
INFLOW air velocity (VINF) is the mean velocity of the inward air flow at the front aperture
which protects the user (BARRIER).
Page 36 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
DOWNFLOW air velocity is the mean velocity of the laminar air flow (LAF) in the working
area which protects the product on the working surfaces (VLAF).
Perform this
measurement by means
of a hot wire
anemometer (see 9.6 –
WARNING) in an
horizontal plane, 70
mm above the top edge
of the front aperture
(see Pic. A2), as per EN
12469, annex G.
The position of the
measurements should
be allocated on 2 rows
and 4 columns,
equispaced as shown in
Pic. A2.
The external
measurement lines are
in correspondence with
the edges of the
measurement area.
Calculate the mean of
the measurements
carried out at the
downflow air (VLAF).
Pic. A2
Page 37 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
NOTICE
The cabinet does not have auto-regulation.
Once reached the desired values, the cabinet is calibrated
and will keep the airflow velocities gradually shrinking them
by clogging of the filter and pre-filter.
We therefore recommend routine controls of the set airflow
velocities.
Pic. A4
Page 38 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pic. A5
Page 39 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
LEGENDA:
1. Upper panel
2. Grill
3. Exhaust pre-filter
4. Plenum
5. Motorblower
6. HEPA Filter.
Pic. A6
Page 40 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 41 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Verify the correspondence of the replacement part with the one to be replaced.
Use only original spare parts.
Page 42 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 43 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 44 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 45 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 46 of 47
80.021.169 r01 – December 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Page 47 of 47
Cabina da banco a flusso laminare verticale
a ricircolo parziale
MANUALE OPERATIVO
PARTE 1: OPERATORE
PARTE 2: ASSISTENZA TECNICA E
MANUTENZIONE
LV30500
ISTRUZIONI ORIGINALI
80.021.169 Revisione 01 Dicembre 2019
BioAir S.p.A.
Uffici e Produzione: Via Lombardia, 12 - 27010 Siziano (PV) Italy
www.bioair.it - info@bioair.it
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
Gentile cliente!
Siamo sicuri che abbiate acquistato un prodotto eccellente e che sarete decisamente
soddisfatti con esso.
Per qualsiasi richiesta, non esitate a contattarci tramite il vostro distributore locale o
direttamente all'indirizzo BIOAIR, saremo lieti di aiutarvi.
assistenza tecnica
parti di ricambio
dati tecnici
contattare:
IN ITALIA ALL’ESTERO
SAT Italia
+ 39 0382 610924
service@bioair.it
sat@bioair.it
BioAir S.p.A.
Via Lombardia, 12
27010 Siziano (PV)
+ 39 0382 6672.1
+ 39 0382 610924
info@bioair.it
Controllare l’etichetta del produttore per conoscere il codice e il numero di serie della cabina.
Pag. 3 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
ETICHETTATURA
Su ogni apparecchio è applicata un’etichetta identificativa come nell’esempio sotto di Fig. 1 con i dati
principali della cabina.
Logo
Nome del costruttore
Indirizzo del costruttore
Marchio CE (solo per Mercato Europeo)
Modello
Codice
Tensione, Frequenza, Potenza
Avvertenze (3)
Numero di serie
Anno di fabbricazione
Norme di conformità (1)
Marchi di Organismi di certificazione (2)
Codici ad uso interno (4)
Fig. 1
SEGNALE DI DISPOSIZIONI
Pag. 4 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
GLOSSARIO
Apf: Fattore di protezione (Aperture protection factor).
DOP: Diffusione di particelle d’olio (Dispersed Oil Particle).
EMC: Compatibilità elettromagnetica (Electromagnetic Compatibility).
EMI: Interferenze elettromagnetiche (Electromagnetic Interference).
Exh: Flusso d’aria espulsa (Exhausted air flow).
HEPA: (Filtro) ad alta efficienza (High Efficiency Particulate Air).
LAF: Flusso laminare (Laminar Air Flow).
MPPS: Diametro della particella più penetrante (Most Penetrating Particle Size).
PELV: Bassissima tensione di protezione (Protection by Extra-Low Voltage)
UV-C: Radiazioni ultraviolette – gamma C (Ultraviolet radiation - range C).
Questo manuale ha lo scopo di spiegare il corretto utilizzo di questa cabina, dotata di flusso laminare
verticale a ricircolo parziale, munita di apertura frontale attraverso la quale l’operatore può eseguire la
manipolazione dei prodotti in ambiente ISO 5 secondo la norma EN 14644-1.
Può essere configurata in modo PROTEZIONE PRODOTTO/OPERATORE (predefinito) o in modo
PROTEZIONE SOLO PRODOTTO.
Il manuale è formato da due parti:
1. La Parte 1 è destinata specificatamente alle istruzioni per l’operatore.
2. La Parte 2 è destinata specificatamente solo alla formazione del personale di assistenza e
manutenzione. Le istruzioni elencate in questa parte non sono destinate all’operatore.
NOTA: il personale di assistenza e manutenzione che interverrà su questa cabina dovrà
comunque essere autorizzato.
Conservare questo manuale sempre vicino alla cabina, in modo da essere velocemente disponibile per
l’uso, l’assistenza, la manutenzione e i controlli periodici.
Le istruzioni date in questo manuale devono esser lette attentamente e comprese prima di avviare
questa cabina, prima di qualsiasi intervento di assistenza e prima di utilizzarla, in modo da raggiungere
una certa familiarità con l’utilizzo e le funzioni, e in modo da evitare un uso improprio.
Sebbene sia stata presa ogni cura nel produrre questo manuale, esso non è destinato a stabilire regole
di procedure in atto presso gli utilizzatori comprese quelle di validazione.
BIOAIR si riserva il diritto di aggiornare o modificare il contenuto del presente manuale in qualunque
momento e senza preavviso.
Pag. 5 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
INDICE
ETICHETTATURA 4
SIGNIFICATO DEI SIMBOLI USATI 4
GLOSSARIO 5
SCOPO ED UTILIZZO DEL MANUALE 5
PARTE 1: OPERATORE 9
1. ANALISI DEI RISCHI 11
1.1. Pericolo di uso improprio. 11
1.2. Pericolo di radiazioni UV-C. 12
1.3. Pericolo di radiazioni UV-C. 12
1.4. Pericolo di propagazione del fuoco. 13
1.5. Pericolo di emissione di gas ed esplosioni. 13
2. NORME IN VIGORE E DEFINIZIONE 14
2.1 DICHIARAZIONE DI CONFORMITÀ CE 14
2.2 DEFINIZIONE 14
3. INSTALLAZIONE 15
3.1 SCELTA DEL POSTO 15
3.2 POSIZIONAMENTO 15
3.3 COLLEGAMENTO ALLA RETE ELETTRICA 15
3.4 PROCEDURE FINALI 16
4. SCHEDA TECNICA 17
4.1 CARATTERISTICHE TECNICHE 17
4.2 CONDIZIONI AMBIENTALI D’USO 17
4.3 CONDIZIONI DI TRASPORTO E IMMAGAZZINAMENTO 17
4.4 PESO E DIMENSIONI 17
4.5 MATERIALI 18
4.6 PRESTAZIONI 18
4.7 DIMENSIONI DEI FILTRI E CARATTERISTICHE 18
4.8 ACCESSORI OPZIONALI PRINCIPALI 18
5. PRINCIPIO OPERATIVO 19
6. DESCRIZIONE DELLA CABINA 20
6.1 PANNELLO COMANDI 20
6.2 RIPIANO DI LAVORO 21
6.3 UTENZE 22
6.4 APERTURA FRONTALE 25
7. ISTRUZIONI OPERATIVE 26
7.1 ACCENSIONE DELLA CABINA 26
7.2 ACCENSIONE LUCE 26
7.3 SPEGNIMENTO LUCE 26
7.4 ACCENSIONE MOTOVENTILATORE 26
7.5 SPEGNIMENTO MOTOVENTILATORE 26
7.6 ATTIVAZIONE PRESA UVC 27
7.7 DISATTIVAZIONE PRESA UVC 27
7.8 SPEGNIMENTO DELLA CABINA 27
7.9 LINEE GUIDA GENERALI 28
8. PULIZIA E MANUTENZIONE ORDINARIA 29
8.1 PULIZIA 29
8.2 DECONTAMINAZIONE 29
Pag. 6 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
Pag. 7 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
ISTRUZIONI ORIGINALI
Pag. 8 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
PARTE 1:
OPERATORE
CABINE
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
AURA MINI è una cabina da banco a flusso laminare verticale con ricircolo d’aria parziale.
NOTA: nonostante la conformità alle norme di riferimento, durante il funzionamento della cabina
rimangono diversi rischi che sono stati valutati in modo da prendere adeguate misure per prevenire i
seguenti pericoli derivanti da uso normale e prevedibile uso improprio:
Generico
Uso improprio
Scossa elettrica
Radiazioni UVC
Propagazione del fuoco dall’apparecchiatura
Emissioni di gas ed esplosioni
L’analisi è stata fatta secondo la norma EN 61010-1:2010, 7.3.3 Allegato J.
PRECAUZIONI DA SEGUIRE:
La cabina deve essere usata esclusivamente da personale autorizzato ed
adeguatamente formato.
Leggere attentamente questo manuale prima di utilizzare la cabina.
Questo manuale deve essere sempre facilmente disponibile.
NON permettere a persone non autorizzate o a pubblico generico di
avvicinarsi alla cabina.
Pag. 11 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
PRECAUZIONI DA SEGUIRE:
Interdire l’accesso a luogo dove è installata la cabina a persone non
autorizzate o a pubblico generico.
Autorizzare all’uso della cabina solo personale qualificato e informato.
Per esposizioni continue e prolungate si consiglia una schermatura
supplementare non trasparente.
Utilizzare solo lampade UV-C raccomandate da BIOAIR.
PRECAUZIONI DA SEGUIRE:
Interdire l’accesso a luogo dove è installata la cabina a persone non
autorizzate o a pubblico generico.
Autorizzare all’uso della cabina solo personale qualificato e informato.
In caso di rottura del vetro durante un ciclo UV-C proteggere immediatamente
occhi e pelle ed inoltre:
allontanare le persone dalla cabina;
spegnere immediatamente la funzione UV-C (o non attivarla);
spegnere la cabina e impedire la riaccensione; e
richiedere l’intervento dell’assistenza tecnica.
Pag. 12 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
PRECAUZIONI DA SEGUIRE:
NON abbandonare la cabina con fiamme accese.
Utilizzare solo la linea gas combustibile per collegare dispositivi per uso di
fiamme.
PRECAUZIONI DA SEGUIRE:
Utilizzare solo Bunsen a gas con fiamma pilota o accensione piezoelettrica.
NON collegare gas combustibile alla linea per vuoto/gas inerti.
NON abbandonare la cabina con fiamme accese.
Riferirsi alle linee guida sull’uso di gas combustibile.
Tenere chiuso il rubinetto del gas se non è utilizzato.
Pag. 13 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Il Fabbricante:
BioAir S.p.A.
Via Lombardia, 12
27010 Siziano (PV)
2.2 DEFINIZIONE
AURA MINI è una cabina di dimensioni contenute a flusso laminare verticale con ricircolo d’aria
parziale progettata per fornire un ambiente sterile in ISO 5 secondo la norma EN 14644-1 nel quale
manipolare i prodotti e nello stesso tempo (secondo la configurazione) proteggere l’operatore da
polveri e fibre rilasciate durante la manipolazione (predefinito) o incrementare la protezione del
prodotto dalla contaminazione esterna.
Pag. 14 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
3. INSTALLAZIONE
3.2 POSIZIONAMENTO
La cabina deve essere fissata su banco o su supporto (non fornito).
È fortemente consigliato l’utilizzo di un supporto dedicato BIOAIR che è
disponibile nella lista degli accessori opzionali.
ATTENZIONE!
La scelta di questo accessorio è sotto completa responsabilità del cliente
Collegare la cabina ad una linea elettrica dedicata, con una presa dotata di
collegamento di terra e posizionata abbastanza vicino (max 2 m), coerente
con la lunghezza del cavo di alimentazione (non sono ammesse prolunghe).
Né oggetti né mobili devono nascondere la spina in modo da poter
scollegare la cabina velocemente in caso di emergenza.
Pag. 15 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Fig. 3
Una targhetta vicino all’ingresso di alimentazione riporta il
valore dei fusibili principali.
Fig. 4
Pag. 16 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
4. SCHEDA TECNICA
Marchi di conformità: |
Norme di riferimento: IEC 61010-1:2010 / EN 61010-1:2010
IEC 61326-1:2012 / EN 61236-1:2013
Isol. elettrico/classe di protezione [IEC 61140]: I
Tensione di alimentazione: 220-230 V~ 50/60 Hz
Fusibili principali: F5A H, 250V
Lampada fluorescente (W): 1x 24 T5 840
Lampade UV-C (W): *
Potenza di linea richiesta (W):
950
(inclusi 3 A di presa di servizio opzionale)
Potenza assorbita (W):
200
(solo motoventilatore e luci)
Massima energia di impatto sostenuta dal vetro
4
[EN 61010-1, paragrafo 8.2.2] (J):
Ritenzione di radiazioni UVC del vetro (%): 98
Indice di tenuta [EN 12469]: NA
Indice di pulibilità [EN 12469]: NA
Indice di sterilizzabilità [EN 12469]: NA
Massima pressione per gas combustibile (mbar): 20*
Massima pressione per vuoto/fluidi inerti (bar): 4*
Corrente massima della presa elettr. di servizio (A): 3*
4.2 CONDIZIONI AMBIENTALI D’USO
Uso: interno
Altitudine (m): fino a 2000
Temperatura (°C): da 10 a 35
80 per temperature fino a 31 °C,
Massima umidità relativa (%):
diminuendo linearmente fino a 50 a 40 °C
Massima variazione di tensione di rete (%): fino a ±10
Categoria di sovratensioni transitorie: II
Grado d’inquinamento: 2
4.3 CONDIZIONI DI TRASPORTO E IMMAGAZZINAMENTO
Temperatura (°C): da -5 a 45
Umidità relativa (%): fino a 90
Pressione atmosferica (mbar): da 800 a 1060
4.4 PESO E DIMENSIONI
Peso (kg): 65
Ingombro complessivo L x P x H (mm): 850 x 590 x 820
Apertura frontale L x H (mm) : 735 x 180/300
Spazio di lavoro L x P x H (mm): 735 x 420 x 480
Area di lavoro sicura L x P (mm): 575 x 260
Spazio operativo necessario intorno (mm):
300 - 0 - 200 - 1000
[sopra - sinistra – destra - davanti]
Pag. 17 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
4.5 MATERIALI
acciaio al carbonio laminato a freddo
Struttura principale: verniciato a forno RAL 7035
Piano di lavoro e parete di fondo: acciaio inox AISI 304 – finitura 2B
Finestra frontale e pareti laterali: vetro di sicurezza temperato
4.6 PRESTAZIONI
Velocità media di flusso laminare [EN 12469](m/s): 0,37 ÷ 0,43
Velocità media di flusso di barriera (m/s): 0,2 ±10%
3
Portata dell’aria espulsa (m /h): 100 ±10%
Rapporto dell’aria espulsa (%): 25 ±10
Apf - Aperture protection factor [EN 12469]:
NA
(Efficienza di ritenzione all’apertura frontale)
Classe di pulizia dell’aria nell’area di lavoro [EN
ISO 5
14644-1]:
Illuminanza [EN 12469] (lux): >750
Sound level [EN ISO 3744] (dB[A]): <65
Vibrazioni [EN 12469] (mm RMS): NA
Incremento massimo delle temperatura all’interno
<5
della cabina rispetto all’ambiente [EN 12469] (°C):
Potenza raggi UV-C emessa da una singola lampada
*
a 1 m (µW/cm2):
Picco di emissione nella gamma UV-C (nm): *
Vita media lampade UV-C (h): *
4.7 DIMENSIONI DEI FILTRI E CARATTERISTICHE
Dimensioni filtro LAF L x D x H (mm): 762 x 305 x 68
Classe di efficienza dei filtri [EN 1822-1]: H14
Efficienza MPPS globale del filtro [EN 1822-1](%): 99,995
Diametro MPPS [EN1822-1](µm): 0,1 ÷ 0,3
NA = non applicabile
* VEDI SCHEDA TECNICA DELL’ACCESSORIO OPZIONALE
**AD ESAURIMENTO
Pag. 18 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
5. PRINCIPIO OPERATIVO
La zona di lavoro viene ventilata mediante un flusso d’aria unidirezionale ricircolato (5), la cui portata è
circa il 80% dell’intero volume d’aria, mentre il restante 20% viene espulso (6) dalla cabina.
Il flusso d’aria totale (100%) è fornito da un ventilatore (4) che soffia l’aria in un plenum dal quale una
parte dell’aria, dopo filtrazione HEPA (1), viene convogliata sul piano di lavoro (2) e la restante viene
espulsa all’esterno della cabina. La cabina può essere configurata in due modi:
A) MODO INFLOW (PREDEFINITO)
PROTEZIONE PRODOTTO/OPERATORE
Questa configurazione(vedi Fig. 5) oltre alla protezione del prodotto fornisce anche la protezione
dell’operatore e dell’ambiente da polveri e fibre rilasciate durante le lavorazioni dei prodotti all’interno
della cabina
L’espulsione dell’aria avviene tramite un’uscita
posizionata sul tetto. L’aria espulsa richiama un
flusso d’aria (3) di uguale volume diretto verso
l’interno attraverso l’apertura frontale che forma
una barriera di protezione per l’operatore. Questo
flusso d’aria di barriera (contaminato dall’esterno)
viene aspirato (7) insieme al flusso d’aria
laminare (contaminato dal prodotto) per formare
il 100% del flusso d’aria (contaminato) e ripetere
il ciclo.
Fig. 5
B) MODO OUTFLOW
PROTEZIONE SOLO PRODOTTO
Questa configurazione (vedi Fig. 6) aumenta la protezione del prodotto evitando l’ingresso d’aria
esterna dall’apertura frontale, eliminando la protezione dell’operatore.
L’espulsione dell’aria avviene tramite l’apertura
frontale. L’aria espulsa richiama un flusso d’aria (3)
di uguale volume diretto verso l’interno attraverso
l’apertura sul tetto. Questo flusso d’aria in ingresso
(contaminato dall’esterno) viene aspirato (4)
insieme al flusso d’aria laminare (contaminato dal
prodotto) per formare il 100% del flusso d’aria
(contaminato) e ripetere il ciclo (7).
La quantità di aria espulsa (3) viene reintegrata
con una eguale quantità di aria ambiente aspirata
attraverso l'apertura superiore (6), generando
nell’apertura frontale una barriera d’aria in uscita.
Fig. 6
Pag. 19 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Fig. 7
Fig. 8
2. contaore di funzionamento (Fig. 9)
viene attivato quando è accesa la
ventilazione.
La sua lettura consente di monitorare
la vita del filtro e programmarne la
sostituzione.
Il contaore non è azzerabile, ed è
quindi necessario registrare data e
numero di ore ad ogni sostituzione
del filtro.
Fig. 9
Pag. 20 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
ACCENSIONE
FAN GREEN FIXED
MOTOVENTILATORE
SPEGNIMENTO
FAN NONE NA
MOTOVENTILATORE
Fig. 11
Pag. 21 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Fig. 12
6.3 UTENZE
6.3.1 Presa per lampada UVC
Questa presa si trova sul lato destro del panello comandi (Fig. 13)
ed è esclusivamente dedicata ad alimentare il kit lampada UV-C
BIOAIR.
Sempre abilitata e interbloccata con la luce fluorescente.
Per attivarla e disattivarla seguire le istruzioni in 7.6 e 7.7
Fig. 13
Pag. 22 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
I rubinetti insieme agli attacchi di ingresso vengono installati attraverso i vetri laterali (Fig.
15) e contrassegnati con etichette adeguate (Fig. 14 e Fig. 16).
Gas combustibile
La linea del gas combustibile è controllata
da un rubinetto a sfera in serie e deve
essere collegata in conformità alle norme
locali.
Il colore della manopola per gas
combustibili è giallo.
Fig. 14
Fig. 16
Pag. 23 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Il KIT va collegato solo alla presa UV-C dedicata (6.3.1) e va inserito nella cabina chiudendo
l’accesso frontale (Fig. 18).
Sempre abilitata e interbloccata con la luce fluorescente.
Per accenderla attivare il timer del KIT per il tempo desiderato e seguire le istruzioni in 7.6
Per spegnerla seguire le istruzioni in 7.7
L’accensione della lampada UV-C è consentita solo con la finestra frontale e il pannello di
chiusura dell’accesso frontale completamente chiusi.
Fig. 17 Fig. 18
Generalmente l’efficacia della disinfezione per mezzo di lampada UV-C (lunghezza d’onda
253,7 nm) dipende dal tempo di esposizione e dalla natura dei microorganismi: queste
informazioni sono fornite da specifiche tabelle.
La bonifica va eseguita al termine di ogni sessione di lavoro.
L’efficienza di questo metodo dipende dal corretto tempo di esposizione della zona di lavoro
della cabina alle radiazioni UV-C.
NOTA: il fatto che le lampade UV producano la luce non è direttamente correlata al loro
potere effettivo di neutralizzazione di microrganismi. La loro effettiva efficacia può essere
controllata con apparecchiature adeguate.
Su richiesta è possibile far eseguire un test di efficienza delle radiazioni emesse dalle
lampade UV-C: contattate il vostro distributore BIOAIR.
Pag. 24 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Fig. 19
Può essere utilizzato nelle seguenti condizioni:
cabina spenta (protezione da polvere e contaminazione esterna);
cabina con ciclo UV-C attivato (se abbinato a lampada UV-C).
Pag. 25 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
7. ISTRUZIONI OPERATIVE
Accendere la cabina tramite
7.1 ACCENSIONE DELLA CABINA l’interruttore generale situato sul lato
destro della cabina (Fig. 7).
Pag. 26 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
NOTA: le funzioni dei pulsanti sono stabili e vengono mantenute in caso di spegnimento della
cabina o di black-out.
Pag. 27 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Pag. 28 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
8.1 PULIZIA
8.2 DECONTAMINAZIONE
La decontaminazione giornaliera della superficie dell’area di lavoro può essere effettuata
per mezzo di radiazioni UV-C (accessorio opzionale).
Pag. 29 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 1: Operatore
ISTRUZIONI ORIGINALI
Pag. 30 di 47
80.021.169 r00 – Dicembre 2015
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
PARTE 2:
ASSISTENZA
TECNICA E
MANUTENZIONE
Tutte le operazioni descritte in questa parte del manuale devono essere
eseguite solo da personale tecnico qualificato, adeguatamente formato ed
autorizzato.
ATTENZIONE!
All’operatore non è consentita alcuna di queste operazioni.
BioAir declina ogni responsabilità per danni derivanti dalla non osservanza di queste disposizioni.
CABINE
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
9. INSTALLAZIONE
NOTA: le operazioni eseguite durante l'installazione devono essere conformi alle disposizioni di
legge in merito alla sicurezza sul lavoro.
La cabina viene spedita su pallet dedicato, avvolta da un pellicola protettiva e cartone esterno.
Per movimentare e sollevare la cabina è necessario l’uso di un carrello elevatore idraulico (trans-
pallet) con forche sollevabili fino ad un’altezza di circa 1 metro. La lunghezza delle forche deve
essere almeno di 70 cm.
Rimuovere l’imballo solo quando il pallet è appoggiato in modo sicuro a terra.
Togliere l’involucro esterno di cartone e rimuovere la pellicola di polietilene che ricopre la cabina.
9.3 POSIZIONAMENTO
La cabina deve essere collocata su un supporto o banco: verificare che
siano adeguati a sopportare il peso della cabina.
La scelta del supporto o banco da usare è sotto totale responsabilità del
ATTENZIONE! cliente.
È fortemente consigliato l’utilizzo di un supporto dedicato BIOAIR che è
disponibile nella lista degli accessori opzionali.
Pag. 33 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
La cabina deve essere messa in bolla. Per la regolazione del piano agire sull’avvitamento
delle ruote
Pag. 34 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Le seguenti verifiche da 0 a 9.6.5 devono essere eseguite con la ventilazione attivata (vedi PARTE 1,
7.4):
NOTA 1: le verifiche sotto descritte sono opzionali e vengono eseguite solo su specifica richiesta del
cliente.
9.6.1 Verifica dell’integrità dei filtri HEPA:
Test: metodo di confronto con aerosol.
Norma di riferimento: EN 12469, allegato D.
Strumenti: generatore di aerosol freddo e fotometro o contatore di particelle.
Accettabilità: la percentuale di di penetrazione di particelle deve essere inferiore a 0,01%
(fotometro) o inferiore a 0,05% (contatore di particelle).
9.6.2 Verifica della pulizia dell’aria:
Test: campionamento dell’aria nella zona di lavoro.
Norma di riferimento: EN 14644-1.
Strumenti: contatore di particelle.
Accettabilità: classe ISO 5 o migliore.
9.6.3 Verifica della velocità del flusso verticale (LAF):
Test: misura della velocità dell’aria nella zona di lavoro (vedi 10.1.3).
Norma di riferimento: EN 12469
Strumenti: anemometro a filo caldo.
Accettabilità: media tra 0,37 e 0,43 m/s.
9.6.4 Verifica della velocità di barriera frontale:
Test: misura della velocità dell’aria di espulsione (vedi 10.1.1).
Norma di riferimento: EN 12469, allegato G.
Strumenti: anemometro a ventola da 100 mm.
Accettabilità: > 0,2 m/s.
9.6.5 Verifica dei flussi d’aria con fumo:
Test: visualizzazione del percorso dei flussi d’aria con generatore di fumo.
Norma di riferimento: EN 12469, Tab. 5.
9.6.6 Verifica di efficienza delle emissioni UV-C:
Strumenti: luxmetro/radiometro con sonda per UV-C.
9.6.7 Strumenti supplementari consigliati:
multimetro digitale per misurare il vero valore efficace (true RMS) in AC;
NOTA 2: i risultati delle prove di flusso laminare e barriera devono essere coerenti con quelli del
rapporto di prova emesso dalla fabbrica (Certificato di qualità), in cui sono indicate le prestazioni e
gli strumenti usati. Le procedure di prova devono essere eseguite secondo quelle definite nel
rapporto di prova di fabbrica.
Pag. 35 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
La velocità dell’aria di BARRIERA (VINF) è la velocità media dell’aria che entrando nella
cabina attraverso l’apertura frontale protegge l’operatore.
Pag. 36 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
La velocità del flusso d’aria di VERTICALE è la velocità media del flusso laminare (LAF)
nell’area di lavoro, che protegge il prodotto sul ripiano di lavoro (VLAF).
Fig. A2
Pag. 37 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
AVVISO
La cabina non è provvista di autoregolazione.
Una volta ottenuti i valori desiderati, la cabina è calibrata
e manterrà le velocità di flusso diminuendole
progressivamente con l’intasarsi del filtro e prefiltro.
Si consiglia pertanto la verifica periodica delle velocità Fig. A4
impostate.
Pag. 38 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Fig. A5
Pag. 39 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
LEGENDA:
1. Pannello superiore;
2. Rete pressafiltro;
3. Prefiltro di espulsione;
4. Plenum;
5. Motoventilatore;
6. Filtro HEPA;
Fig. A6
Pag. 40 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 41 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 42 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 43 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 44 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 45 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 46 di 47
80.021.169 r01 – Dicembre 2019
Manuale Operativo Aura MINI
Parte 2: Assistenza Tecnica e manutenzione
ISTRUZIONI ORIGINALI
Pag. 47 di 47