C86

Multi-parameter Patient Monitor

Recommended configuration
operating room ICU CCU general ward

12-lead ECG
MASIMO SpO2

Comen SpO2

Side-stream EtCO2

● 15 inch LCD touch screen Mainstream EtCO2

BIS

C.O.

IBP

AG
ICG

C86 multi-parameter patient monitor is designed to meet every care of patients in clinical, configuring 15” LCD touch screen, fixed
handle, mounting solutions, it is therefore your optimal choice for acute care.
In case of different clinical environment such as in ICU, C86 provides IPX1 waterproof protection to satisfying strict environment
requirements.

Shenzhen Comen Medical Instruments Co., Ltd.


1639

Add: Floor 10, Floor 11 and Section C of Floor 12 of Building 1A &Floor 1 to Floor 5
of Building 2, FIYTA Timepiece Building, Nanhuan Avenue, Matian Sub-district,
Guangming District, Shenzhen, Guangdong, 518106,P.R. China
C86
Tel:+86-755-2640 8879 Fax:+86-755-2643 1232 Website: en.comen.com E-mail: info@szcomen.com

P/N:EN-C86-6P-20200319-V1.4 Multi-parameter Patient Monitor


Fixed handle, more compact Aesthetically pleasing USB, VGA, network Wall mount, trolley High-capacity of Lithium
with small weight, easy to new interface design and multi-functional battery support long
carry interface working time without
power supply
AG (Anesthetic Gas)
AcuTecTM NIBP technology, high accuracy for Cooperate with MASIMO, adopts the advanced anesthetic gas
hypertension monitoring. module for monitoring 8 types of gas (O2, CO2, N2O, ENF, ISO,
With leading ECG technology, anti-motion and Hypoperfusion SPO2 technology as well as accurate NIBP measurement The initial inflatable pressure can be selected to DES, SEV, HAL). Automatic identification of the anesthetic gas,
technology and cooperation with word leading medical technique providers such as Masimo, Covidien, Respironics, improve the accuracy of measurement and the short time for warm-up, long service life and supports the MAC
Medis, C86 is designed to optimize performances by configuring CO2, AG, BIS and noninvasive hemodynamic comfort of patients. value (minimum alveolar concentration).
monitoring into one, helping you care even the most critical patients with professional assistance.

ICG (Impedance Cardiography)


Cooperate with MEDIS, impedance cardiography for non-
invasive continuous hemodynamic monitoring.
Micro-signal transmit through disposable electrode.
Blood volume and Blood Flow Velocity varies with heartbeat,
DISQ® technology processes impedance signal variation.
3/5/12-lead ECG measurement technology, leads Variation of impedance applies to non-invasive Z MARCTM
automatic identification algorithm for acquiring SV, CO, SVR, Contractility and TFC etc.
Intelligent leads off detection and automatically leads
selection guarantee uninterrupted monitoring
ECG ensures intensive monitoring for a particular waveform
CMRR≥105dB, outstanding ECG anti-interference capability 2-channel IBP, monitoring ART, PA, CVP, LAP, RAP,
Support arrhymia analysis & ST segment analysis ICP etc

C.O. (Cardiac Output)


I-KLOK® intelligent alarm management, C86 is involved itself in invasive cardiac output technique, but C.O.
auto-identification of alarm level. Self-adjust measurement is conducted with conventional thermo dilution invasive
Cooperate with US RESPIRONICS, MASIMO, Plug and Play EtCO2 monitoring.
proper alarm time to reduce false alarms. cardiac output and other hemodynamic parameters. The monitor can
Use CAPNOSTAT 5 / IRMA mainstream sensor for optimal performance in monitoring intubated patient.
measure “blood temperature”, “calculating cardiac output”, “calculating
Small, durable and lightweight mainstream sensor provides accurate and reliable monitoring for all intubated patients from hemodynamics”. Cardiac output is measured by introducing a floating
neonates to adults. catheter from the vein into the pulmonary artery and then injecting a
No calibration required. certain amount of 0 °C ice-water mixture (injection) through a floating
Use LoFlo / ISA sidestream sensor for monitoring non-intubated patient. catheter. When the injection is mixed with blood output from the heart,
the temperature of blood changes. By measuring the change in blood
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal.
temperature before and after injection, cardiac output is obtained
Sample rate ≤ 50ml/min(micro-stream). according to the principle of heat balance.

Masimo SpO2
MasimoSET
Performance Claim Pulse Oximeter
SpO2 Accuracy (70-100%)
Adult/Pediatric (No Motion) ±2 digits

Adult/Pediatric (Motion)
BIS (Bispectral Index) module
±3 digits

Perfusion Index Range 0.02% - 20%

Pulse Rate Accuracy (70%-100%) The BIS module has been designed to be used in the monitoring of the level of consciousness of a person
during the application of general anaesthesia or in intensive care. This is accomplished by registering the
Pulse Rate(No Motion) 25 - 240 bpm ±3 digits
electroencephalo-graph (EEG) signal by means of surface electrodes which is then analyzed by a digital
Pulse Rate(Motion) 25 - 240 bpm ±5 digits process. As a result of the applied calculation, an index “BIS” is obtained, which serves as guidance to Support wired & wireless central monitoring system.
the experts who use it to determine consciousness level of patient during surgery.