DESIGN OF COLUMN COL.

N0:- C1 1

Load on a column P= 520 KN SUMMERY


Width of column b= 200 mm LOAD- 520 KN
Depth of column D= 400 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 400
Hence column can be designed as a short one with axial load BAR:- 6 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 80000 sqmm
Ultimate load on column 1.5xP Pu= 780 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 454 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 320 sqmm
PROVIDE 6 6Y14BAR
MAIN BARS
14 Asc(pro) = 923 sqmm
AREA PROVIDED OK
DESIGN OF COLUMN COL. N0:- C2
Load on a column P= 660 KN SUMMERY
Width of column b= 200 mm LOAD- 660 KN
Depth of column D= 500 mm SIZE:-
Column clear height between end restraints,Lo = 2700 mm
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 500
Hence column can be designed as a short one with axial load BAR:- 8 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 100000 sqmm
Ultimate load on column 1.5xP Pu= 990 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 616 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm
PROVIDE 6 8Y14BAR
MAIN BARS
14 Asc(pro) = 1231 sqmm
AREA PROVIDED OK

DESIGN OF COLUMN COL. N0:- C3 2

Load on a column P= 800 KN SUMMERY


Width of column b= 200 mm LOAD- 800 KN
Depth of column D= 600 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 600
Hence column can be designed as a short one with axial load BAR:- 10 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 120000 sqmm
Ultimate load on column 1.5xP Pu= 1200 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 779 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 480 sqmm
PROVIDE 6 10Y14BAR MAIN BARS
14 Asc(pro) = 1539 sqmm
AREA PROVIDED OK
DESIGN OF COLUMN COL. N0:- C4 2

Load on a column P= 930 KN SUMMERY


Width of column b= 200 mm LOAD- 930 KN
Depth of column D= 700 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 700
Hence column can be designed as a short one with axial load BAR:- 12 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 140000 sqmm
Ultimate load on column 1.5xP Pu= 1395 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 892 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm
PROVIDE 6 12Y14BAR MAIN BARS
14 Asc(pro) = 1846 sqmm
DESIGN OF COLUMN COL. N0:- C5 2

Load on a column P= 1070 KN SUMMERY


Width of column b= 200 mm LOAD- 1070 KN
Depth of column D= 800 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 800
Hence column can be designed as a short one with axial load BAR:- 14 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 160000 sqmm
Ultimate load on column 1.5xP Pu= 1605 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 1055 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 640 sqmm
PROVIDE 6 14Y14BAR MAIN BARS
14 Asc(pro) = 2154 sqmm
DESIGN OF COLUMN COL. N0:- C6 2

Load on a column P= 1070 KN SUMMERY


Width of column b= 200 mm LOAD- 1070 KN
Depth of column D= 900 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 900
Hence column can be designed as a short one with axial load BAR:- 16 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 180000 sqmm
Ultimate load on column 1.5xP Pu= 1605 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 535 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 720 sqmm
PROVIDE 6 16Y14BAR MAIN BARS
14 Asc(pro) = 2462 sqmm
DESIGN OF COLUMN COL. N0:- C7 2

Load on a column P= 150 KN SUMMERY


Width of column b= 200 mm LOAD- 150 KN
Depth of column D= 300 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 300
Hence column can be designed as a short one with axial load BAR:- 6 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 60000 sqmm
Ultimate load on column 1.5xP Pu= 225 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -827 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 240 sqmm
PROVIDE 6 6Y14BAR
MAIN BARS
14 Asc(pro) = 923 sqmm